32
Cooper-Atkins Corporation HVAC/R OEM INDUSTRIAL www.cooper-atkins.com

Cooper-Atkins Corporation - microtherm.commicrotherm.com/atkins/images/id_catalog.pdf · Cooper-Atkins Corporation ... Cooper has built a solid ... Our commitment to the industries

  • Upload
    hadung

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

Cooper-Atkins Corporation

HVAC/R • OEM • INDUSTRIAL

www.cooper-atkins.com

Since our establishment in 1885, Cooper has built a solid reputation as a manufacturer and provider of quality time, temperature and humidity instruments. We take extreme pride in our service levels and in our customer relationships. Thesequalities have helped our business grow for over 118 years.

In today’s rapidly changing world, innovations in technology have brought about dramatic changes in our industry. To betterserve our valued customers, we at Cooper Instrument haveexpanded our technological capabilities by purchasing AtkinsTechnical, a leader in thermocouple technology, and KTG, Inc., a provider of problem solving software and wireless monitoring hardware.

Our newly formed organization will be known as Cooper-Atkinsand will have the capability to meet our customers’ needs with a wide array of measurement solutions. By exercising the synergies within our three locations, we are committed to pursuing the potential of all measuring system technologies with the expertise to support them. Our products will continueto be offered through the brand names our customers have cometo rely on. We will continue to provide exceptional customerservice and quality products. These elements along with productinnovations, will drive our company to consistently exceed ourcustomers’ expectations.

Our commitment to the industries we serve is captured in our mission and vision statements:

Mission

As an innovative global partner, we deliver measuring systems to help our customers ensure safe food and healthyindoor environments.

Vision

To be the global leader in innovative food safety and indoor environment solutions.

Carol P. WallacePresident/CEOCooper-Atkins

A Message from the President/CEO: Carol P. Wallace

Thermocouple/Thermistor Temperature Instruments . . . . . . . . . . . . . . .2-3

Humidity/Temperature Instruments . . . . . . . .4-5

Thermistor Probes . . . . . . . . . . . . . . . . . . . .6-7

Thermocouple Probes . . . . . . . . . . . . . . . . . .8-9

Accessories . . . . . . . . . . . . . . . . . . . . . . . .10-11

Digital Pocket Thermometers . . . . . . . . . . . . .12

Glass Stick Pocket Thermometers . . . . . . . . . .13

Analog Pocket Thermometers . . . . . . . . . . . . .14

Industrial Stem Thermometers . . . . . . . . . . . .15

Digital Remote Panel Thermometers . . . . .16-17

Remote Vapor Tension Panel Thermometers . . . . . . . . . . . . . . . . .18-19

Storage/Wall Thermometers . . . . . . . . . . . .20-21

Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Refrigerator/Freezer Thermometers . . . . . . . .23

Cooking/Prep Thermometers . . . . . . . . . . . . . .24

Infrared Thermometers . . . . . . . . . . . . . . . . .25

Merchandising . . . . . . . . . . . . . . . . . . . . . .26-27

Glossary of Terms . . . . . . . . . . . . . . . . . . .28-29

Table of Contents

1

Featured New Products & Product Updates

NEW Model 4005/4005MK — Pipe Clamp Probes

NEW Model SRH122 — Digital Pocket Psychrometer

Portable size makes this instrument easy to carry and it is ideal for spot-checks. See page 4 for additional information.

NEW Model DRH122 — Hygrometer/Thermometer Pen

Compact and easy-to-use, this multi-purposeinstrument reads both temperature and relative humidity. See page 4 for additional information.

NEW GL100 — Water-Resistant Mini Data Logger

NEW SP160 — Digital Solar Remote Panel Thermometer

UPDATED PM120 — Rectangular DigitalRemote Panel Thermometer

NEW PM120RH — Digital RemoteTemperature/Humidity Panel Meter

NEW 4011 — Pipe Strap Probe

NEW 5028 — Slim Humidity Probe

NEW DFP450W — Waterproof Digital Pocket Thermometer

Fast, accurate temperature measurements of pipe diameters up to 1-3/8" (34.9 mm). See page 6for Model 4005 thermistor version and page 8 for Model 4005MK TypeK thermocouple version.

Small and easy-to-use, this minidata logger is self powered andrecords temperatures accurately atintervals from 1 minute to 4 hours.See page 11 for additional information.

Compact size allows for easy installation. Solar and battery powered eliminates the need for any external power supply. See page 16 for additional information.

This popular remote panelthermometer is now °F/°Cswitchable. See page 16for additional information.

Monitor both temperature and humidity simultaneouslywith this compact remotepanel thermometer. See page 16 for additional information.

Easily attach thisnew pipe strap probe to pipes up to 5" (127 mm) in diameter. See page 6 for additional information.

This humidity probe isthe perfect solutionfor air ducts and smallspaces. See page 6 for additional information.

Waterproof, field calibrateable, dropresistant, rugged,Lifetime Warranty...need we say more! See page 12 for additional information.

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

2

Thermistor Temperature Instruments

ThermocoupleThermistor Temperature Instruments

Model SH88AThis is the perfect tool for the heating, ventilation, air-conditioningand refrigeration (HVAC/R) technician. The primary function of this instrument is to measure thetemperature and pressure values of arefrigeration system and calculate thesystem’s superheat. The instrument iscapable of measuring superheat of 16of the most common refrigerants.

Model SH88A includes:(1) Model 4010 Surface Probe, (1) Model 5027 Brass PressureTransducer, (1) T-Fitting, (1)Adapter, and a rugged polyethylene storage case with removable cover

Thermistor Superheat Calculator

• Automatically calculates superheat• Altitude and refrigerant selector• Special T-fitting allows monitoring of

refrigerants while recharging the system

ThermistorTemperature InstrumentsModel SH66ASeriesFor applications where multiple temperature measurements need to betaken, this is the instrumentto use. Measure suction andliquid line temperaturessimultaneously, temperaturesacross condensing coils, evaporator coils, as well asthe ambient temperature,all at the same time!

The Constant Scan feature records themin/max temperature from three probes allowing the technician to monitor critical temperatures remotely whilecompleting other tasks.

Model SH66A includes: (1) Model 1075 General Purpose PunctureProbe, (1) Model 2010 Air Probe, (1) Model 4011 Surface Probe

Model SH66AC includes: (1) Model 1075 General PurposePuncture Probe, (1) Model 2010 Air Probe, (1) Model 4011 SurfaceProbe, 7-Language Instruction Booklet, and is °C prominent

• 3-Zone• Min/Max memory

Model SH44ASeriesThe SH44A is an economical alternativewith the durability ofModel SH66A. This dual-zone unit allows for accurate temperaturemeasurement of two areas at once.

Model SH44A includes: (1) Model1075 General Purpose PunctureProbe and (1) Model 4010 Surface Probe

Model SH44AC includes: (1) Model 1075 General PurposePuncture Probe, (1) Model 4010 Surface Probe, 7-LanguageInstruction Booklet, and is °C prominent

• Dual zone• Min/Max memory• Scan mode• Auto shut-off

Models TM99A, TC100ASeriesFor those applications where only one temperature is read at a time, this series of single zone temperature meters is an industry standard. Choose from thebasic Model TM99A, the UL approvedModel TM99A-UL or the rechargeableModel TC100A.

Model TM99A includes: (1) Model1075 General Purpose Puncture Probe andhard carrying/storage case

Model TM99AC includes: (1)Model 1075 General Purpose Puncture Probe, hard carrying/storage case, 7-Language Instruction Booklet, and is °C prominent

Model TM99A-UL includes: (1) Model 1075 General PurposePuncture Probe, hard carrying/storage case, UL approved (Class 1, Groups C & D), and temperature code T3C

Model TC100A includes: (1) Model 1075 General Purpose PunctureProbe, hard carrying/storage case, NiCad battery, and battery charger

• Single zone• Min/Max memory

• Hold button• Auto shut-off

• Scan mode• Auto shut-off with override

Model FW2000MKWhen choosing a durable thermometer with fastresponse, the FW2000MK is a wise decision. Thisinstrument is ergonomicallydesigned, NSF certified, andis waterproof making itideal for harsh wet andsteam filled environments.

The FW2000MK can withstand a drop of six feet(1.83 meters) without damage to the unit. The probe cord has beenenhanced toextend its flexstrength to over50,000 bends.

Model FW2000MK includes: (1) Model 1410MK-FWQuick Response Probe

• Waterproof• Quick response• Field calibration• Auto shut-off

Models TD2000 and TD2000-01For those tough-working environments where you need a durable thermocouple thermometer that will withstand

punishment, this is the perfectinstrument. The TD2000 is wellsuited to industrial environmentsand can handle temperature ranges of up to 2,000°F (1093°C).For added durability, the instrumenthas a protective rubber boot thatshields it from damage if dropped.The dual input jacks allow the operator to monitor two locationsat once. Once temperatures arestabilized you can display the temperature delta between the twoprobes. The TD2000 is ideal formonitoring temperature differentials

in heating and cooling equipment.

Model TD2000 includes: (2) Model 6030MK BeadProbes, wrist strap

Model TD2000-01 includes: (2) Model 6030MK BeadProbes and (1) 1070MK Puncture Probe, wrist strap

• Heavy-duty• Dual input• Field calibration

• Hold button and max temperature display

ThermocoupleTemperatureInstruments

Thermocouple • •

Thermistor • • • • •

Temperature -100° to 999°F -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°F -58° to 2000°F -40° to 300°FRange -73° to 537°C -40° to 150°C -40° to 150°C -40° to 150°C -40° to 150°C -50° to 1093°C -40° to 150°C

Temperature ±2°F/1°C ±0.3°F/0.2°C ±0.3°F/0.2°C ±0.3°F/0.2°C ±0.3°F/0.2°C ±4°F from 58° ±0.3°F/0.2°CAccuracy or ±0.5% Rdg, or ±0.5% Rdg, or ±0.5% Rdg, or ±0.5% Rdg, to 32°F, ±0.3% or ±0.5% Rdg,

whichever whichever whichever whichever + 2°F from whicheveris greater is greater is greater is greater 32° to 2000°F is greater

Ambient Temp. 0° to 115°F 0° to 130°F 0° to 130°F 0° to 130°F 0° to 130°F 32° to 122°F 0° to 130°FRange -18° to 46°C -18° to 54°C -18° to 54°C -18° to 54°C -18° to 54°C 0° to 50°C -18° to 54°C

max max max max max

Resolution 1°F/°C 0.1°F/°C 0.1°F/°C 0.1°F/°C 0.1°F/°C 1°F/°C 0.1°F/°C

Pressure 0 to 300 psiRange

Pressure 1% psi ofAccuracy full scale

Superheat 0 to 200 psiRange

Display 3 digit .5" 4 digit .5" 4 digit .5" 4 digit .5" 4 digit .5" 3.5 digit .5" 4 digit .5"12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD

Backlight • • • •

LO • • • • •

HI • • • • •

LO-P • • • • •

°F • • • • • •

°C • • • • • •

PSI •

Kgf/cm2 •

bar •

1, 2 or 3 • • •

CL • • • •

SCAN •

Case ABS Polyethylene Polyethylene Polyethylene Polyethylene ABS PolyethyleneMaterial Plastic Plastic

Case 6.45" x 2.25" 9.5" x 6.5" 9.5" x 6.5" 13.5" x 9.5" 7" x 3" 6" x 2.5" 7" x 3"Dimensions x 1.5" x 3.5" x 3.5" x 4.25" x 1" x 1.56" x 1"

163.8 x 57.2 241.3 x 165.1 241.3 x 165.1 343 x 241.3 177.8 x 76.2 152.4 x 63.5 177.8 x 76.2x 38.1 mm x 89 mm x 89 mm x 108 mm x 25.4 mm x 39.6 mm x 25.4 mm

Weight 7.6 oz/215 g 1.46 lbs/662 g 1.55 lbs/703 g 3.42 lbs/1551 g 1.27 lbs/576 g 12.5 oz/354 g 1.27 lbs/576 g

Power (1) 9V Alkaline (1) 9V Alkaline (1) 9V Alkaline (6) AA (1) 9V Nicad (1) 9V Alkaline (1) 9V Alkaline

Battery Life 500 hours 90 hours 90 hours 90 hours 90 hours 200 hours 90 hours

Calibration

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELSTM99A

SH44A SH66A TD2000 TM99ACFW2000MK SH44AC SH66AC SH88A TC100A TD2000-01 TM99A-UL

INDICATIONS

Temperature Instrument Specs

See glossary for indication definitions

Factory calibrated to specifications. Field calibrateable

3

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

4

Humidity/Temperature Instruments

Model SRH77A SeriesWhere temperature and relative humidity readings are important, Model SRH77A is the expert’s choice. Whether it be HVAC/R applications, storage management, computer room monitoring or troubleshooting, the operator will find this to be anaccurate and fast service tool.

The bright blue rugged carry case makes this tool easy to find when on location or in the back of a service truck. Features include a backlight display for darkenvironments, sealed keypad which protects the instrument from spills and dust,and a battery eliminator jack.

Model SRH77A includes: (1) Model 1075 General Purpose Puncture Probe,(1) Model 4010 Surface Probe, (1) Model 5028 Humidity Probe

Model SRH77AC includes: (1) Model 1075 General Purpose Puncture Probe,(1) Model 4010 Surface Probe, (1) Model 5028 Humidity Probe, 7-LanguageInstruction Booklet, and is °C prominent

• 3-zone• Min/Max memory• Scan mode• Auto shut-off after 15 minutes of non-use or

continuous ON mode• Temperature differential between zones 1 and 2• %RH and wet bulb• Switchable °F/°C

Model SRH122 – Digital PsychrometerNo more water, no more twirling, and no more charts! Use actual wet bulb measurements with this DigitalPocket Psychrometer. Model SRH122 gives fast,accurate measurement of wet bulb, dewpoint, temperature, and humidityat an economical price.

• Displays: wet-bulb, dew point,temperature, and humidity

• Min/Max memory• Data hold• Auto shut-off after

20 minutes of non-use• Switchable °F/°C

Model 9349Optional Nylon Belt Pouch

Model DRH122 – Thermo-Hygrometer PenMeasure and display environment temperatures and humidity readingsin a matter of seconds with this compact Thermo-Hygrometer Pen. Model DRH122 is designed for simplicity and one-handed operation. This economical instrumentis a valuable preventive maintenance and quality assurance tool.

• Displays: temperature and humidity• Min/Max memory• Switchable °F/°C

Thermistor • • • • •

Temperature -40° to 300°F -4° to 122°F 14° to 122°F 32° to 122°F 14° to 140°FRange -40° to 150°C -20° to 50°C -10° to 50°C 0° to 50°C -10° to 60°C

Temperature ±.5% Rdg or ±1.8°F°/1.0°C ±2°F/1.0°C ±2°F from ±1.8°F/1.0°CAccuracy ±.3°F/.2°C 32 - 104°F

whichever is ±4°F abovegreater 104°F

Ambient Temp. 0° to 130°F -4° to 122°F 14° to 122°F 32° to 122°F 14° to 122°FRange -18° to 54°C max -20° to 50°C max -10° to 50°C max 0° to 50°C max -10° to 50°C max

Resolution 0.1°F/°C, 1% RH 0.1°F/°C, 0.1% RH 0.1°F/°C, 1% RH 0.1°F/°C, 1% RH 0.1°F/°C, 1% RH

Humidity 10 to 95% RH 0 to 100% RH 20 to 90% RH 25 to 95% RH 10 to 99% RHRange

Humidity ±2% from 20 ±3% from 10 ±5% from 40 ±5% from 40 ±5% from 25Accuracy to 80% RH to 90% RH to 80% RH to 80% RH to 95% RH

±3% below 20% ±4% below 10% ±7% below 40% ±7% below 40% ±7% below 25%and above and above and above and above and above80% RH 90% RH 80% RH 80% RH 95% RH

Ambient 10 to 95% RH, 0 to 100% RH 10 to 95% RH 10 to 95% RH 10 to 100% RHHumidity 90%Range non-condensing

Display 4 digit, .5" .25" x .35" .25" LCD Dual .5" Dual .43"12.7 mm LCD 6.5 x 9 mm LCD 6.3 mm 12.7 mm LCD 11 mm LCD

Backlight •

LO •

HI •

LO-P •

°F • • • • •

°C • • • • •

1, 2 or 3 •

CL •

SCAN •

%RH • • • • •

Case Polyethylene ABS ABS ABS ABSMaterial Carry Case

Case 9.5" x 6.5" x 3.5" 6.88" x 1.5" x 0.9" 5.94" x .79" x .67" 7" x 3.16" x .75" 4.35" x 2.77" x .75"Dimensions 241.3 x 165.1 174.7 x 38.1 150.9 x 20 177.8 x 80.3 110.5 x 70.4

x 89 mm x 22.8 mm x 17 mm x 19 mm x 19 mm

Weight 1.9 lbs/862 g 2.5 oz/71 g 0.8 oz/23 g 3.9 oz/111 g 2.9 oz/82 g

Power (1) 9V Alkaline (1) 3V CR2032 (1) 1.5V LR44 (2) 1.5V AA (1) 1.5V AAA

Battery Life 90 hours 100 hours 1 year 1 year 1 year

Calibration Factory Factory Factory Factory FactoryCalibrated Calibrated Calibrated Calibrated Calibrated

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year

MODELSSRH77ASRH77AC SRH122 DRH122 TRH122 TRH122M

Humidity/Temperature Instrument Specs

INDICATIONS

5

Model TRH122 and Model TRH122MMonitoring relative humidity is as crucial as monitoring temperatures in many applications.Relative humidity affects the comfort level in homesand offices, is important in horticulture, and plays an important part in storage, whether it be of food or personal belongings. These light weight units are easy to use and can be permanently mounted to a wall.

Model TRH122• Measures

temperature and %RH

• Accurate internal sensors

• Switchable °F/°C

• Measures temperature and %RH• Accurate internal sensors• Switchable °F/°C• Min/Max memory feature

Model TRH122M

See glossaryfor indicationdefinitions

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • cooper-atkins.com

6

Thermistor ProbesFor use with all Cooper thermistor instruments

Model 1013 – Meat packing puncture probe

Model 1014 – 17" (431.8 mm) puncture probe with heavy-duty cord

Model 1050 – Blunt tip veterinary probe

Model 1075 – General purposepuncture probe

Model 2007 – Blunt tip waterproof probe

Model 1030 – Screw-in probewith 1/8" (3.2 mm)NPT fitting

Model 1052 – Needle probe

Model 1078 – 7.25" (184.2 mm)puncture probe

Model 2010 – Air probe

Model 3010 – Plastic shaft probewith aluminum tip

Model 4040 – Fast surface contact probe

Model 5026R – Humidity/Incubator probe

Model 7010 – Air/surface probewith phone plugfield assembly

Model 4011 – Pipe strap probe

Model 5005 – Air probe

Model 5028 – Slim humidity probe

.140"/3.6 mm Ø

.125"/3.2 mm Ø

.250"/6.4 mm Ø

.165"/4.2 mm Ø

.041"/1 mm Ø

.140"/3.6 mm Ø

.140"/3.6 mm Ø

.14"/3.6 mm Ø

.16"/4.1 mm Ø

.156"/4 mm Ø

.31"/7.9 mm Ø

.125"/3.2 mm Ø

.16"/4.1 mm Ø

Model 4005 – Pipe clamp probe

.250"/6.4 mm Ø

Temperature -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°FRange -40° to 149°C -40° to 149°C -40° to 149°C -40° to 149°C -40° to 149°C -40° to 149°C -40° to 149°C -40° to 149°C

Max Tip 300°F/149°C 300°F/149°C 300°F/149°C 300°F/149°C 300°F/149°C 300°F/149°C 300°F/149°C 300°F/149°CTemp

Max Cord 200°F/93°C 200°F/93°C 400°F/204°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 400°F/204°CTemp

Response 6 seconds 100 seconds 20 seconds 6 seconds 4 seconds 6 seconds 6 seconds 18 secondsTime

Sensor Type Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor

Shaft Length 4"/101.6 mm 17"/431.8 mm 2.5"/63.5 mm 3.4"/86.4 mm 2.9"/73.6 mm 4"/101.6 mm 7.25"/184.2 mm 4"/101.6 mm

Cord Length 6'/1.83 m 6'/1.83 m 6'/1.83 m teflon 6'/1.83 m 6'/1.83 m 6'/1.83 m 6'/1.83 m 10'/3.1 m teflon polyurethane uncoiled polyurethane uncoiled straight cord polyurethane uncoiled polyurethane uncoiled polyurethane uncoiled polyurethane uncoiled straight cord

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS

1013 1014 1030 1050 1052 1075 1078 2007

Thermistor Probe Specs

Temperature -40° to 200°F -40° to 300°F -20° to 300°F -25° to 212°F -40° to 300°F -40° to 300°F 32° to 130°F 0° to 150°F -40° to 200°FRange -40° to 93°C -40° to 149°C -29° to 149°C -32° to 100°C -40° to 149°C -40° to 149°C 0° to 54°C -18° to 66°C -40° to 93°C

Humidity 10 to 95% RH 10 to 95% RHRange

Max Tip 200°F/93°C 200°F/93°C N/A 212°F/100°C 300°F/149°C 300°F/149°C 130°F/54°C 150°F/66°C 200°F/93°CTemp

Max Cord 200°F/93°C 200°F/93°C 220°F/105°C 200°F/93°C 200°F/93°C 200°F/93°C 176°F/80°C 200°F/93°C 200°F/93°CTemp

Response 20 seconds 15 seconds 12 seconds 15 seconds 2 minutes 6 seconds 20 secondsTime

Sensor Type Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor Thermistor

Shaft Length 0.5"/12.7 mm 3"/76.2 mm N/A N/A 3.5"/84 mm 4.25"/108 mm 6.25"/159 mm 4.9"/124.5 mm 0.5"/12.7 mm

Cord Length 12'/3.7 m 6'/1.83 m 10'/3.1 m TPE 12'/3.7 m 6'/1.83 m 6'/1.83 m 6'/1.83 m 6'/1.83 m 6"/152.4 mm polyurethane polyurethane straight cord straight cord polyurethane polyurethane polyurethane coiled cord polyurethanestraight cord uncoiled uncoiled uncoiled uncoiled

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS

2010 3010 4005 4011 4040 5005 5026R 5028 7010

7

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • cooper-atkins.com

8

Thermocouple ProbesCompatible with all Type K Thermocouple Instrumentswith miniature connectors

Model 1075MK – Puncture probe, semi-pointed tip, high temperature

Model 1410MK – Quick response large needle probe

Model 1420MK – Angled surface probe

Model 4022MK – 5.25" (133.4 mm) surface probe

Model 1410MK-FW – FW2000MK replacement probe

Model 3110MK – 10" (254 mm) vat probe

Model 5000MK – Air probe with high temperature wire

Model 6010MK – 48" (1.2 meters) flexible SS oven probe

Model 6030MK – 42" (1.07 meters) bead probe

Model 6050MK – Flexible teflon probe

.098"/2.5 mm Ø.062”/1.6 mm Ø

.50"/

12.7 m

m Ø

.140"/3.6 mm Ø

.250"/6.4 mm Ø

.50"/12.7 mm Ø

.125"/3.2 mm Ø

.098"/2.5 mm Ø

.062"/1.6 mm Ø

Model 3130MK – 30" (762 mm) vat probe(not shown)

Model 4005MK – Pipe clamp probe

Temperature -100° to 900°F -100° to 500°F -100° to 500°F -100° to 500°F -100° to 900°F -100° to 900°FRange -73° to 482°C -73° to 260°C -73° to 260°C -73° to 260°C -73° to 482°C -73° to 482°C

Max Tip 900°F/482°C 500°F/260°C 500°F/260°C 500°F/260°C 900°F/482°C 900°F/482°CTemp

Max Cord 220°F/105°C 200°F/93°C 200°F/93°C 200°F/93°C 500°F/260°C 500°F/260°CTemp

Response 19 seconds 1 second 1 second 2 seconds 1 second 1 secondTime

Sensor Type Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple

Shaft Length 4"/101.6 mm 3.85"/97.8 mm 3"/76.2 mm 5.5"/139.8 mm 10"/254 mm 30"/762 mm

Cord Length 3' 4'/1.2 m 32"/813 mm 4'/1.2 m 35"/889 mm 35"/889 mm0.9 m TPE polyurethane uncoiled silicone straight cord polyurethane uncoiled SS flexible hose SS flexible hose

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS

1075MK 1410MK 1410MK-FW 1420MK 3110MK 3130MK

Thermocouple Probe Specs

Temperature -20° to 300°F -100° to 1400°F -100° to 900°F -100° to 900°F -100° to 500°F -100° to 500°FRange -29° to 149°C -73° to 760°C -73° to 482°F -73° to 482°F -73° to 260°C -73° to 260°C

Max Tip N/A 1400°F/760°C 900°F/482°C 900°F/482°C 500°F/260°C 500°F/260°CTemp

Max Cord 200°F/93°C 220°F/105°C 220°F/105°C 900°F/482°C 500°F/260°C 500°F/260°CTemp

Response 2 seconds 3 seconds 18 seconds 18 seconds .5 second 1 secondTime

Sensor Type Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple Thermocouple

Shaft Length N/A 5.25"/133.4 mm 4.25"/108 mm N/A N/A 0.5"/12.7 mm

Cord Length 10'/3.1 m 3'/0.9 m 42"/1.07 m 4'/1.2 m 42"/1.07 m 4'/1.2 mpolyurethane straight cord TPE straight cord TPE straight cord stainless steel overbraid teflon straight cord teflon straight cord

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS

4005MK 4022MK 5000MK 6010MK 6030MK 6050MK

9

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

10

Protective Cases

Accessories

Model 87-430010-1 Safely protect your instrument with this hard polyethylene storage case. For use with Models TM99A and TC100A.

Wire Cable

Model 13-75860024-AWG 2-conductor wire allows user to extend the leads on a thermistor unit. This wire is sold by the foot.

Model 37-56The 1/8" (3.2 mm) vessel clip is for our smaller diameter stem thermometers. This clip is a great tool for use inphoto labs and laboratory applications.

Model 9339 Transport your thermometer safely in this soft carry case/holster. This pouch attaches to your belt and the Velcro flap keeps the unit stored safely inside. For use with Models 460, TD2000, TD2000-01, 4005 and 4005MK.

Model 9348Protect your investment with this durablerubber boot designed specifically for theFW2000 series. Features include a Velcrostrap for securing to a belt and the ribbedbacking lessens the shock to the unit ifdropped.

Model 9349This compact nylon pouch featuring a sturdy belt clip safely holds your Model SRH122.

Model 9402Durable water-resistant nylon construction gives extra protectionto Models 401 and 411 infraredthermometers.

Model 9010This 10' (3.1 m)extensioncable allowsan operator toextend certain leadsdepending on useand location. Can beused with any Cooperthermistor probe.

Model 9015This high quality 50'(15.2 m) extensioncable will accurately

send temperaturereadings to your

display. It is recommendedthat cable lengths do not

exceed 1,000' (304.8 m)toinsure instrument accuracy. Can

be used with any Cooper thermistor probe.

Model 13-999249Type K, 24 AWG stranded wire, with glass braid insulation.Temperature range: -100° to 900°F/-73° to 482°C. This wire is sold by the foot.

Model 9335Replacement cable/probe for Model DTT361.

Accessories/Miscellaneous

Accessories/Miscellaneous

Model 9317Battery eliminator, 9 VDC 100MAregulated. For use with ModelsSH88A, SH66A and SRH77A.

Model 9313Battery eliminator, 9 VDC 100MA regulated.

For use with Models TM99A and TC100A.

Model 93023.56" x 3" (90.4 x 76.2 mm)mounting flange is requiredwhen mounting Model PM120in an opening that is largerthen the unit itself. It fills thespace and securely holds theunit in place.

Model 7042Add more value to your Model SH88A with this accessory kit

which includes: battery eliminator, 4010 surfacetemperature probe, adapter, and T-fitting.

Model 9315Prover/Calibration Box provides a standard to calibrate your Cooper Instrument thermistor based instruments against. Learn how to adjust and calibrate your thermometer for ensured accuracy.

• Monitors both time and temperature• Records at specific intervals from 1 minute to 4 hours• Mounting bracket with adhesive backing• Stainless steel bead chain, to hang from racks or hooks• Long-life battery

GL Series – Water-Resistant Mini Data Loggers

Temperature Range -13°to 185°F (-25° to 85°C)

Temperature ±2°F from -4° to 158°FAccuracy ±1°C from -20° to 70°C

Clock Accuracy ±2 minutes per month

Overall Tag Dimension 2" x 2-5/8"/50.8 x 66.7 mm

Records 2,048

PC Requirements Windows 95 or higher, Minimum of 10MB of free hard drive space and CD-Rom (will not work on Macintosh computers)

Warranty 1 Year

GL100 Series – Water Resistant Mini Data Loggers

Probe WipesModel 9150These individually packaged probe wipes clean without skin contact.Packaged in a master carton that holds 10 boxes of 200 single usewipes, each wipe contains 70% Isopropyl Alcohol.

11

GL100 includes:(2) two mini data loggers,(2) two mounts, reader and software

Gl00-02 includes:(2) two mini data loggers,(2) two mounts

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

12

Digital Pocket Thermometers

From laboratories to the service repairman, these fast response digitalpocket thermometers will simplify any user’s job.

• Waterproof• Min/Max/Temperature hold• Auto shut-off• °F/°C switchable• NSF Certified

Model DFP450W

• On/Off switch• °F/°C switchable

• Waterproof• Field calibrateable• Max temperature hold• Auto shut-off• °F/°C switchable• Lifetime warranty• NSF Certified

Model DPP400W

Model DT300

®

®

Temperature -40° to 450°F -40° to 392°F -40° to 302°F DPS300:Range -40° to 232°C -40° to 200°C -40° to 150°C -58° to 302°F

DPS300C:-50° to 150°C

Accuracy ±2°F/1°C ±2°F/1°C from ±2°F/1°C from 1.8°F/1°C from14° to 212°F/ -10° to 212°F/ 0° to 160°F/-10° to 100°C -23° to 100°C -18° to 71°C

±3°F/1.5°C ±4°F/2°C ±3.6°F/2°Call other ranges all other ranges all other ranges

Display .25"/12.7 mm LCD .25"/12.7 mm LCD .25"/12.7 mm LCD .25"/12.7 mm LCD

Stem Length 4.625"/117.5 mm 2.75"/69.9 mm 4.625"/117.5 mm 5"/127 mm

Resolution 0.1°F/°C 0.1°F from -40 - 199°F 0.1°F/°C 0.1°F/°C

1°F from 200 - 392°F

0.1°C throughoutthe entire range

Power (1) 1.5V #392 (1) 1.5V #A76 (1) 1.5V #A76 (1) 1.5V #A76

Auto Shut-Off After 10 minutes of After 5 minutes ofnon-use non-use N/A N/A

Weight 0.7 oz/20 g 0.9 oz/26 g 0.7 oz/20 g 0.8 oz/23 g

RegulatoryListings NSF NSF N/A N/A

Warranty Lifetime 1 Year 1 Year 1 Year

MODELSDPS300

DFP450W DPP400W DT300 Series

Digital PocketThermometer Specs

Model 1051 Series

• Large bore tempered-glass tube

• Non-toxic fluid• Plastic case with

metal clip

Glass Stick Pocket Thermometers

Glass Stick PocketThermometer Specs

Temperature 0° to 220°F -30° to 120°FRange

Accuracy ±3°F ±3°F

Dial N/A N/A

Stem Length 5"/127 mm 5"/127 mm

Weight 0.6 oz/17 g 0.6 oz/17 g

Regulatory N/A N/AListings

Warranty 1 Year 1 Year

MODELS1051-03 1051-04

Model DPS300 and DPS300C

• Swivel head - turns 30°, 60° or 90°• DPS300 - °F only; DPS300C - °C only

Model DPS300

13

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

14

Analog Pocket Thermometers

Analog Pocket Thermometers

Model 1246 Series Model CT180 / CT220 Series

The analog pocket thermometer is an economical, quick and easy way to monitor temperatures with excellent repeatability.

• Field calibrateable• Red protective sheath includes calibration wrench• 1" (25.4 mm) magnifying lens• 5" (127 mm) stem length• NSF Certified

• Field calibrateable• Red protective sheath• 1" (25.4 mm) magnifying lens• 5" (127 mm) stem length

Model 2236 Series Model 2238 Series

• Field calibrateable• Red protective sheath• 2" (50.8 mm) lens• 5" (127 mm) stem length

• Field calibrateable• 2" (50.8 mm) lens• 8" (203.2 mm) stem length• Vessel clip provided

®

Analog Pocket Thermometer Specs

Temperature 0° to 220°F -40° to 180°F 0° to 200°FRange -10° to 100°C -40° to 80°C -10° to 100°C

Accuracy ±2°F/1°C ±2°F/1°C ±2°F/1°C

Dial 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia.

Stem Length 5"/127 mm 8"/203.2 mm 8"/203.2 mm

Weight 1.2 oz/34 g 1.25 oz/35 g 1.25 oz/35 g

Regulatory N/A N/A NSFListings

Warranty 1 Year 1 Year 1 Year

Temperature -40° to 180°F 0° to 220°F CT180: CT220: -40° to 180°FRange -40° to 180°F 0° to 220°F -40° to 80°C

CT180C: CT220C:-40° to 80°C -20° to 100°C

Accuracy ±2°F ±2°F ±4°F/2°C ±4°F/2°C ±2°F/1°C

Dial 1"/25.4 mm dia. 1"/25.4 mm dia. 1"/25.4 mm dia. 1"/25.4 mm dia. 2"/50.8 mm dia.

Stem Length 5"/127 mm 5"/127 mm 5"/127 mm 5"/127 mm 5"/127 mm

Weight 0.7 oz/20 g 0.7 oz/20 g 0.7 oz/20 g 0.7 oz/20 g 1.2 oz/34 g

Regulatory NSF NSF N/A N/A N/AListings

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS1246-01 1246-02 CT180 Series CT220 Series 2236-02

Temperature 2225-02: 0° to 220°F 2245-02: 0° to 220°F 2255-02: 0° to 220°FRange

2225-03: -40° to 160°F 2245-03: -40° to 160°F 2255-03: -40° to 160°F

2225-05: 200° to 1000°F

Accuracy 2225-02: ±2°F 2245-02: ±2°F 2255-02: ±2°F

2225-03: ±3°F 2245-03: ±3°F 2255-03: ±3°F

2225-05: ±20°F

Dial 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia.

Stem Length 4"/101.6 mm 6"/152.4 mm 9"/228.6 mm

Weight 2.7 oz/77 g 2.9 oz/82 g 3.0 oz/85 g

Warranty 1 Year 1 Year 1 Year

Industrial StemThermometer Specs

MODELS2225 Series 2245 Series 2255 Series

Industrial Stem ThermometersThe 2" dials are printed with large black numerals forease in viewing. Offered with three temperature rangesand various stem lengths, these thermometers are anexcellent choice for a variety of industrial applications.

• Bimetal coil movement and glass lens• .25" (6.4 mm) diameter stainless steel stem• Back flange bezel, chrome plated with

(3) .150" (3.8 mm) diameter mounting holes equally spaced on a 2.9" (73.6 mm) diameter bolt circle

Model 2225 Series

Model 2245 Series

Model 2255 Series

MODELS2236-06 2238-02 2238-06

15

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

16

Rectangular Digital Remote Panel Thermometers

Digital RemotePanel Thermometers

Model SP160When temperature monitoring is essential and space is limited, the SP160 is the ultimate panel thermometer. Not only does the compact size allow the SP160 to fit in most places that other panel thermometers cannot - it does not require any external power sources.

Digital Solar Remote Panel Thermometers

• Solar/battery powered• Easy-to-read LCD display

Model PM120 – Digital Remote Temperature Panel MeterWhen mounting space is limited, the digital Model PM120 is an ideal solution. This rectangular mini remote reading thermometer is °F and °C switchable.

• Max/Min button/hold down to clear

• On/Off button

Model SP120This solar powered instrument is an attractive alternative in thoseapplications where conventional vapor tension panel thermometershave been used. When the ambient light is not strong enough to powerthe meter, the 1.5 volt battery automatically turns the unit on.

• Unit operates using ambient light (natural, fluorescent and incandescent)

• Solar/battery powered• Switchable °F/°C

Model PM120RH – Digital Remote Temperature/Humidity Panel MeterNow monitor both temperature and humidity at once with this newcompact remote panel meter.

• Clear button• Dry/Comfort/Wet

icon shows on the LCD display

• Max/Min button/hold down to clear

Model DM120 Series / DM450 SeriesWhen a cabinet and / or enclosure requires fast andaccurate temperature readings, the DM120 and DM450series are the best choice. With the removable lens, battery replacement is easy.

Front & Back Flange Digital RemotePanel Thermometers

Model DM120

Model DM120S

Model DM450

Thermistor • • • • • •

Temperature -58° to 158°F -58° to 158°F -40° to 122°F -12° to 140°F DM120/DM120S: DM450/DM450S:Range -50° to 70°C -40° to 50°C -24.4° to 60°C -40° to 120°F -40° to 450°F

DM120CS: -40° to 50°C

Humidity 10 to 99% RHRange

Temperature ±2°F from -4 ±3°F ±2°F from -40 ±2°F from -12 ±2°F/±1°C from ±2% of readingAccuracy to 31.9°F ±1.5°C to 122°F to 140°F -4°F/-20°C to

±1°F from 32 77°F/25°C to 122°F ±1°C from -12 ±1°C from -24.4 ±4°F/±2°C below

±3.6°F below -4 to 50°C to 60°C -4°F/-20°C and and above 122°F above 77°F/25°C

Humidity ±5% 30 to Accuracy 75%, with

temperature from32 to 122°F 0 to 50°C

Ambient Temp. 0° to 120°F 0° to 120°F 0° to 120°F 0° to 120°F 0° to 150°F 0° to 150°F Range max -18° to 50°C -18° to 50°C -18° to 50°C -18° to 65°C max

max max max max

Resolution 0.1°F 0.1°F/°C 0.1°F/°C 0.1°F/°C 0.1°F/°C 0.1°F

Response 10 seconds 10 seconds 30 seconds 30 seconds 10 seconds 10 secondsTime

Display 1.4" x .5" LCD 1.825" x .625" 1.825" x .625" 1.825" x .625" 1.3" x .5" 1.3" x .5"35.6 x 12.7 mm 46.4 x 46.4 x 46.4 x 33 x 12.7 mm 33 x 12.7 mm

LCD 15.9 mm LCD 15.9 mm LCD 15.9 mm LCD LCD LCD

Lux Rating Above 100 Above 100 N/A N/A N/A N/A

Lead Length 4'/1.2 m 10'/3.1 m 39"/1 m 39"/1 m 39"/1 m 39"/1 m

Mounting Hangs Hangs Optional Optional DM120/DM120C: DM450:mounting flange mounting flange front flange front flange(Model 9302) (Model 9302)

DM120S/ DM450S:DM120CS: Back flange,

Back flange, surface mountsurface mount

Indications N/A N/A N/A Flashing HHH/HI: Flashing HHH/HI:Shorted probe or Shorted probe orabove max. temp. above max. temp.Flashing LLL/LO: Flashing LLL/LO:Open probe or Open probe or

below minimum below minimumtemperature temperature

Lens 2"/50.8 mm dia. 2"/50.8 mm dia.polycarbonate polycarbonate

Case Material Polycarbonate Polycarbonate Stainless steel Stainless steel

Case 4.5" x 1.125" 2.77" x 2.68" 2.7" x 1.4" 2.7" x 1.4" DM120 Series: DM450:Dimensions x .625" x .68" x 1.1" x 1.1" 2.97" x 1.08" 2.97" x 1.08"

75.4 x 27.4 mm 75.4 x 27.4 mm114.3 x 28.6 70.4 x 68 68.6 x 35.6 68.6 x 35.6x 15.9 mm x 17.3 mm x 28 mm x 28 mm DM120S Series: DM450S:

3.47" x 1.1" 3.47" x 1.1"88.1 x 28 mm 88.1 x 28 mm

Weight 3.1 oz 3 oz 3.3 oz 3.3 oz DM120/DM120C: DM450:88 g 85 g 94 g 94 g 3.8 oz/108 g 4.4 oz/125 g

DM120S/DM120CS: DM450S:4.6 oz/130 g 5.2 oz/147 g

Power Solar / Solar / (1) AA (1) AA (1) 1.5V #393 (1) 1.5V #393(1) 1.5V AAA (1) 1.5V A76

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELSDM120 DM450

SP160 SP120 PM120 PMRH120 Series Series

Digital Remote Panel Meter Specs

17

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

18

Remote Vapor Tension Panel Thermometers

Remote vapor tension panel thermometers are used in many HVAC/R applications. Offering various temperature ranges these are the perfectchoice for use in walk-in refrigerators, tanks, refrigerated display cases, holding cabinets, dairy cases, freezers, floral displays and much more.

• Recalibrateable• Dual scale dial• 48" (1.2 m) capillary (except where noted)• Nickel/Tin plated bulb and capillary• Polycarbonate lens/bezel• Stainless steel cases• Bright buffed flange (6142, 6812 and 7112 series)

Models 8122-01 and 8822-01

Model 7612-06

• Recalibrateable• Dual scale dial• 48" (1.2 m) capillary• Nickel/Tin plated bulb and capillary• Polycarbonate lens/bezel• Black painted cases

Model 6142 Series

Model 6642 Series

Model 6742-19

Model 6812 Series

Model 7112 Series

Model 8122-01

Model 8822-01

Temperature 40° to 240°F -40 to 120°F -40° to 60°F -40° to 60°F -40° to 60°F 40° to 240°F -40° to 60°F -40° to 60°FRange 10° to 115°C -40 to 50°C -40° to 15°C -40° to 15°C -40° to 15°C 10° to 115°C -40° to 15°C -40° to 15°C

Accuracy ±5°F @ 110°F ±2°F @ 40°F ±2°F from ±2°F from ±2°F from ±5°F @ 110°F ±2°F from ±2°F from±3°F @ 200°F ±4°F @ 10°F 10° to 40°F 10° to 40°F 10° to 40°F ±3°F @200°F 10° to 40°F 10° to 40°F

±5°F @ 110°F±2.5°C @ 43°C ±3°F below 10°F ±3°F below 10°F ±3°F below 10°F ±2.5°C @ 43°C ±3°F below 10°F ±3°F below 10°F±1.5°C @ 93°C ±1°C @ 4°C and above 40°F and above 40°F and above 40°F ±1.5°C @ 93°C and above 40°F and above 40°F

±2°C @ -12°C±2.5°C @ 43°C ±1°C from ±1°C from ±1°C from ±1°C from ±1°C from

-12° to 4°C -12° to 4°C -12° to 4°C -12° to 4°C -12° to 4°C

±1.5°C below -12°C ±1.5°C below -12°C ±1.5°C below -12°C ±1.5°C below -12°C ±1.5°C below -12°Cand above 4°C and above 4°C and above 4°C and above 4°C and above 4°C

Dial 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia. 2"/50.8 mm dia.

Capillary 48" 48" 48" 240" 48" 48" 48" 48"Length 1.2 m 1.2 m 1.2 m 6.1 m 1.2 m 1.2 m 1.2 m 1.2 m

Flange Front Front Front Front Strap hanger Strap hanger U bracket Backno flange no flange no flange

Connection Back Back Back Back Bottom Bottom Back Back

Mounting Flush Flush Flush Flush N/A N/A N/A Surface

Weight 5.2 oz/147 g 5.2 oz/147 g 4.7 oz/133 g 6.8 oz/193 g 4.6 oz/130 g 5.1 oz/145 g 5.6 oz/159 g 5.7 oz/162 g

Regulatory NSF NSF NSF N/A N/A N/A NSF NSFListings

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS

6142-06 6142-13 6142-20 6142-58 6642-06 6642-12 6742-19 6812-01

Remote Vapor Tension Panel Thermometer Specs

Temperature -40° to 120°F 40° to 240°F -40° to 60°F -40° to 120°F 40° to 240°F -40° to 60°F -40° to 60°F -40° to 60°FRange -40° to 50°C 10° to 115°C -40° to 15°C -40° to 50°C 10° to 115°C -40° to 15°C -40° to 15°C -40° to 15°C

Accuracy ±2°F @ 40°F ±2°F @ 40°F ±2°F @ 40°F ±2°F @ 40°F ±2°F @ 40°F ±2°F @ 40°F ±2°F @ 40°F ±2°F @ 40°F±4°F @10°F ±4°F @10°F ±4°F @10°F ±4°F @10°F ±4°F @10°F ±4°F @10°F ±4°F @10°F ±4°F @10°F

±5°F @ 110°F ±5°F @ 110°F ±5°F @ 110°F ±5°F @ 110°F ±5°F @ 110°F ±5°F @ 110°F ±5°F @ 110°F ±5°F @ 110°F

±1°C @ 4°C ±1°C @ 4°C ±1°C @ 4°C ±1°C @ 4°C ±1°C @ 4°C ±1°C @ 4°C ±1°C @ 4°C ±1°C @ 4°C±2°C @ -12°C ±2°C @ -12°C ±2°C @ -12°C ±2°C @ -12°C ±2°C @ -12°C ±2°C @ -12°C ±2°C @ -12°C ±2°C @ -12°C±2.5°C @ 43°C ±2.5°C @ 43°C ±2.5°C @ 43°C ±2.5°C @ 43°C ±2.5°C @ 43°C ±2.5°C @ 43°C ±2.5°C @ 43°C ±2.5°C @ 43°C

Dial 2"/50.8 mm dia. 2"/50.8 mm dia. 2.5"/63.5 mm dia. 2.5"/63.5 mm dia. 2.5"/63.5 mm dia. 2.5"/63.5 mm dia. 3.5"/89 mm dia. 3.5"/89 mm dia.

Capillary 48" 48" 48" 48" 48" 48" 48" 48"Length 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m

Flange Back Back Front Front Front Strap Hanger Front BackNo Flange

Connection Back Back Back Back Back Bottom Back Back

Mounting Surface Surface Flush Flush Flush N/A Flush Surface

Weight 6.2 oz/176 g 6.2 oz/176 g 5.3 oz/150 g 5.8 oz/164 g 5.8 oz/164 g 5.6 oz/159 g 9.0 oz/255 g 9.0 oz/255 g

Regulatory N/A N/A NSF N/A N/A N/A N/A N/AListings

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS

6812-02 6812-03 7112-01 7112-02 7112-05 7612-06 8122-01 8822-01

19

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

20

Storage/WallThermometers

Model 212 Series Brightly colored, oversized wall thermometers allow easy monitoringof temperatures in critical food-related locations.

Storage Thermometers

• HACCP reference color zoned dial• Bimetal coil movement• Large black pointer makes viewing easy

Model 255 Series Compact version of the 212 series.

212-146 - CoolerThermometer

212-147 - FreezerThermometer

• HACCP reference color zoned dial• Bimetal coil movement• Large black pointer makes viewing easy

255-12 - Freezer Thermometer

255-13 - CoolerThermometer

21

Temperature 212-146 Cooler 255-12 Freezer -40° to 120°F -40° to 120°F IO158: Range Therm: 10° to 80°F Therm: -10° to 80°F -40° to 50°C -40° to 50°C -58° to 158°F

212-147 Freezer 255-13 Cooler IO158C:Therm: -10° to 80°F Therm: 10° to 80°F -50° to 70°C

Accuracy ±2°F ±2°F ±2°F ±2°F ±2°F/1°C±1°C ±1°C or 2% of reading

Dial/Lens 12.5"/317.5 mm dia 6"/152.4 mm dia N/A N/A N/A

Sensor Length N/A N/A N/A N/A 10'/3.048 m

Weight 21 oz/595 g 3.1 oz/88 g 1.7 oz/48 g 1.9 oz/54 g 5.5 oz/156 g

Power N/A N/A N/A N/A (1) 1.5V AAA

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS212 255 IO158

Series Series 264 268 Series

Storage/Wall Thermometer SpecsModel 264

Indoor/OutdoorStorage/WallThermometers

• Non-toxic spirit-filledglass tube

• Brown polystyrene back• White reverse printing• Measures 7.7" x 2"

(195.6 x 50.8 mm)

Model 268

• Non-toxic spirit-filled glass tube

• Clear polystyrene back• Black printing• Two suction cups• Measures 7.7" x 2"

(195.6 x 50.8 mm)

Model IO158 Series (IO158 °F only; IO158C °C only)

• Hard-wired sensor• Min/Max memory• Thermistor sensor• Large 2.5" x 3" (63.5 x 76.2 mm) LCD

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

22

Timers

Model FT24The FT24 timer has both a visual and audio alarm. The audio alarm has a volume control.

The FT24 automatically counts upwards once the time set has elapsed, letting you know howlong it has been since the timer wentoff. A one-touch start/stop button is conveniently located on the topof the unit.

• Volume controlled alarm• Oversized LCD• Red light flashes when alarm sounds• Splash-proof keypad• Built-in memory for repeat cycle timing• Measures 7" H x 6" W x 4" D (177.8 x 152.4 x 101.6 mm)

Model TCS24The TCS24 is a multi-function unit with clock, timer, and stopwatch allin one. This pocket sized timer is light enough to carry or clip on yourshirt or coat pocket without being cumbersome. This unit can bemounted to a metal surface via its magneticback or placed on acounter top with thefold out easel stand.

• Clock/timer/stopwatch• Counts up or down in 1-second intervals• 24-hour capability• Flip out stand and magnetic back

Model TS100This popular lightweight timer/stopwatchfeatures an 18" (457 mm) soft nylonneck cord. The TS100 was designedwith a simple 3-button function:minutes, seconds, and start/stop.For repetitive timing, the recall feature automatically brings thecounter back to a previously set time.

• Timer/Stopwatch• 18" (457 mm) nylon neck cord• Recall feature, returns to previously set time• 99 minute, 59 second counter/timer

Model MT60Simply turn the dial to the desired setting and this timer accuratelycounts down.

• Easy to read numerals• Spring wound, with sturdy molded case• Unit will lay flat, stand or can be hung

23

Display 2.25" x .812" 1.5625" x .4375" .375" x .812" N/A57 x 20.6 mm 39.7 x 11.1 mm 9.5 x 20.6 mm

Weight 1.175 lbs/533 g 1.9 oz/54 g 0.9 oz/26 g 3.2 oz/91 g

Power (4) C (1) 1.5V AAA (1) 1.5V #A76 N/A

Warranty 1 Year 1 Year 1 Year 1 Year

Timer Specs

Temperature -20° to 80°F Model 335: -40° to 80°F -40° to 120°F -20° to 120°FRange -30 to 30°C Model 335C: -40° to 25°C -40° to 50°C -30° to 50°C

Accuracy ±2°F/1°C ±2°F/1°C ±2°F/1°C ±5°F

Dial 2"/50.8 mm 5" w x 1" h 2.75" x .625" 2"/50.8 mm diameter 127 w x 25.4 h mm 69.9 x 15.9 mm diameter

Weight 1.5 oz/43 g 1.1 oz/31 g 0.25 oz/7 g 0.3 oz/8 g

Regulatory NSF N/A NSF N/AListings

Warranty 1 Year 1 Year 1 Year 1 Year

Refrigerator/Freezer ThermometersModel 25HP – Dial Thermometer

• Zoned with specific applications and HACCP guidelines

• Sturdy stainless steel construction• Includes dry storage range• Hangs or stands• NSF Certified

Model 335 – Horizontal Tube Thermometer

• Aluminum casing• Magnifying lens• Hangs, stands, or permanently mounts• Non-toxic, spirit-filled glass tube

Model 330 – Thermometer

• Lightweight design• Durable plastic casing• Non-toxic, spirit-filled

glass tube• NSF Certified

Model 535 – Dial Thermometer

• Magnetic back• Self adhesive tabs for permanent mounting

See

glos

sary

for i

ndic

atio

n de

finiti

ons

Refrigerator/FreezerThermometer Specs

MODELS25HP 335 Series 330 535

MODELSFT24 TCS24 TS100 MT60

®

®

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

24

Model DTT361 – Digital Thermometer/Timer/Clock

Cooking/PrepThermometers

• Heat resistant stainless steel probe• Wall mount bracket and magnet supplied• Easy to read LCD• Max temperature setting w/alarm

Model QC450 – Frozen Food Thermometer

Model 24HP – Oven Dial Thermometer

• HACCP guidelines• Hangs or stands• Sturdy stainless

steel construction• NSF Certified

Model 26HP – Hot Holding Dial Thermometer

• Color zoned dial with HACCP guidelines

• Hangs or stands• Sturdy stainless

steel construction• NSF Certified

Model 323 – Meat Thermometer

• Color zoned dial with HACCP guidelines• Sturdy stainless steel construction• Pointer for accurate measurements• NSF Certified

• Sensor and display are integrated in the stainless steel probe for easy one-handed operation

• Waterproof enclosure allows for accurate use in wet environments

• Instant read display• Automatic shut-off after

50 minutes of non-use

®

®

®

Temperature 200° to 600° F 100° to 175°F 130° to 190°F 32° to 392°F -40° to 450°FRange 100° to 300°C 38° to 80°C 54° to 88°C 0° to 200°C

Temperature ±25°F/±12°C ±3°F/±1.5°C ±2°F/±1°C ±4°F/±2°C ±2°F/±1°C fromAccuracy -4°/-20° to 160°F/71°C

±4°F/±2°C over remaining range

Dial/Display 2"/50.8 mm 2"/50.8 mm 2.5"/63.5 mm 1.875" x 1.375" LCD .75" x .375" LCDdiameter diameter diameter 47.6 x 34.9 mm 19 x 9.5 mm

Resolution N/A N/A N/A 1°F/°C 0.1°F

Probe Length N/A N/A 6"/152.4 mm 3'/914.4 mm probe wire 3.875"/98.43 mm

Weight 1.5 oz/43 g 1.5 oz/43 g 2.5 oz/71 g 4.5 oz/128 g 3.3 oz/94 g

Power N/A N/A N/A (1) 1.5V AAA (1) 1.5V AAA

Regulatory NSF NSF NSF N/A N/AListings

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year

MODELS24HP 26HP 323 DTT361 QC450

Cooking/Prep Thermometer Specs

Infrared ThermometersNon-contact infrared thermometers measure surface temperatures fast and easily. Suitable for use in

HVAC/R, industrial, food processing, automotive and foodservice applications.

Model 411 – • Point and shoot with

instant results• LCD display with

backlight• Maximum temperature

display• FDA Class II laser may

be turned on or off• 8-point circular laser• °F/°C switchable• 7-second display hold

Model 460 – • Point and shoot with

instant results• Time saver: fast,

accurate temperaturemeasurement

• Safe, non-contact surface thermometer

• FDA Class II laser pointer• °F/°C switchable• 7-second temperature hold

Model 4400MK – Thermocouple Probe

Infrared Thermometer SpecsMODELS

411 460 4400MK

Temperature Model 401 0° to 500° 0° to 500°Range -32° to 400°F/-25° to 750°C -18° to 260°C -18° to 260°C

Model 411-32° to 510°F/-25° to 950°C

Accuracy 1% or ±2°F/±1°C, whichever ±2% or ±3°F/±2°C at 77°F/ ±2% of reading or ±3°F/±2°C,is greater above 73°F/23°C, 25°C whichever is greater, whichever is greater at ±3°F /±2°C @ 0° to 73°F/ 30°F/-1°C to 77°F/25°C 81°F/27°C ambient operating-18° to 23°C, ±4°F/±2.5°C ±5°F/±3°C, temperature@ -15° to 0°F/-26°to -18°C, 0°F/-18°C to 30°F/1°C±5°F/±3°C @ -25° to -15°F/ ±7°F/±4°C

-32° to 26°C

Resolution 0.5°F/0.2°C

Repeatability ≤±0.5% or ≤±2°F/±1°C, ±2% of reading, or ±3°F/±2°C ±1% of reading, or ±2°F/±1°Cwhichever is greater whichever is greater whichever is greater

Response 500mSec (95% of reading) 500mSec (95% of reading) 1 Sec (95% of reading)Time

Spectral 8 to 14 µm 7 to 18 µm 8 to 14 µmResponse Pyroelectric detector

Ambient 32° to 120°F 32° to 120°F 32° to 150°FOperating 0° to 50°C 0° to 50°C 0° to 65°CRange

Laser Max Laser turns off above 104°F/40°C ambient temperature

Relative 10 to 95% RH noncondensing, 10 to 95% RH noncondensing, 10 to 95% RH noncondensing,Humidity at 86° to 122°F/30° to 50°C at 86° to 122°F/30° to 50°C at up to 86°F/30°C

Storage -13° to 158°F -4° to 150°F -13° to 158°FTemperature -20° to 60°C without battery -20° to 65°C without battery -25° to 70°C

Power (1) 9V Alkaline or NiCad battery (1) 9V Alkaline or NiCad battery (1) 9V Alkaline

Battery Life 10 hours with laser and backlight ON Non-laser models:100 hrs 50 hours at 73°F/23°C40 hours with laser and backlight OFF Laser Models: 12 hrs

Distance Model 401, 12:1 6:1 4:1to Spot (D:S) Model 411, 12:1

(90% encircled energy atfocal point)

Emissivity Preset at 0.95 Preset at 0.95 Preset at 0.95

Weight 11 oz/312 g 8 oz/227 g 6.4 oz/182 g

Dimensions 8" x 6" x 2" 7.25" x 1.75" x 1.5" 7.1" x 1.2" x 2" 203 x 152 x 51 mm 184 x 45 x 38 mm 180 x 31 x 51 mm

Warranty 1 Year 1 Year 1 Year

• Ergonomic design• Sturdy construction

25

Floor Display: Model LFD-11-7 includes:Quantity Model # Description

2 each Model SRH77A-E Multi-Zone Humidity/Temperature Instrument

2 each Model SH66A-E Multi-Zone Temperature Instrument

3 each Model 4005 Thermistor Pipe Clamp Probe

3 each Model TD2000 Dual Zone Thermocouple Temperature Instrument

3 each Model 4005MK Thermocouple Pipe Clamp Probe

4 each Model 1075 Thermistor General Purpose Probe

4 each Model 2010 Thermistor Air Probe

4 each Model 4010 Thermistor Surface Probe

4 each Model 5026R Humidity Probe

Quantity Model # Description

2 each Model SRH77A-E Multi-Zone Humidity/Temperature Instrument

3 each Model 4005 Thermistor Pipe Clamp Probe

3 each Model TD2000 Dual Zone Thermocouple Temperature Instrument

3 each Model 4005MK Thermocouple Pipe Clamp Probe

12 each Model DRH122 Temperature/Humidity Pen (6 fit in display at one time)

4 each Model SRH122 Digital Pocket Psychrometer

6 each Model 1075 Thermistor General Purpose Probe

12 each DFP450W Waterproof Digital Pocket Thermometer (6 fit in display at one time)

50 each 8-panel brochures w/literature holder

Quantity Model # Description

2 each Model SRH77A-E Multi-Zone Humidity/Temperature Instrument

2 each Model SH66A-E Multi-Zone Temperature Instrument

4 each Model SRH122 Digital Pocket Psychrometer

12 each Model DFP450W Waterproof Digital Pocket Thermometer (6 fit in display at one time)

4 each Model 1075 Thermistor General Purpose Probe

4 each Model 2010 Thermistor Air Probe

4 each Model 4010 Thermistor Surface Probe

4 each Model 5026R Humidity Probe

Counter Day In A Box• Place an order for one floor display (Models LFD-11-7, LFD-12-7, LFD-13-7 shown above)

• Order to include purchased date, purchase order number, floor display part number, date of counter day, branch manager name, and phone number

You Receive FREE6 each Golf shirts (sizes must be specified on order form)

6 each Tee shirts (sizes must be specified on order form)

6 each Baseball caps

1 each Counter mat

50 each 8-panel brochures with counter holder

MerchandisingCooper’s new floor displays and counter packs offer in-store merchandising materials that will create excitementand generate impulse sales. These colorful displays andother merchandising materials available will help draw

attention to thoseCooper itemsneeded by thecontractor.

Floor Display: Model LFD-12-7 includes:

Floor Display: Model LFD-13-7 includes:

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • cooper-atkins.com

26

CT Series Counter Prepacks

Pipe Clamp Probe Display Giveaway• Place an order for 10 each Model 4005 or Model 4005MK Pipe

Clamp Probes (can be combined)

Other promotional materials• Counter mats

• 8-panel brochures with counter holder

Contact your local representative for availability

Quantity Model # Description

Receive FREE• Pipe clamp probe

demo display with 50 each 8-panel brochures (display can hang on slatwall or stand on the counter)

Pegboard/Slatwall Overlay w/Cooper Header24" x 48" (.6 x 1.2 m) wall overlay with perforated holes to align with peg board (can also be used on slatwall). 12pt C1Swhite board with 4/color full bleed screenprinted header.

Contact your local representative for availability

27

12 per display Model CT180-0-6 Analog Pocket Thermometer

12 per display Model CT180-C-6 Analog Pocket Thermometer

12 per display Model CT220-0-6 Analog Pocket Thermometer

12 per display Model CT220-C-6 Analog Pocket Thermometer

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • www.cooper-atkins.com

28

Glossary of Terms

°C: Celsius (or centigrade) relationship between Centigrade and Fahrenheitcan be found by multiplying Celsius degrees by 1.8 and then adding 32. Forexample 20°C is equal to 20 x 1.8 +32 = 68°F.

°F: Fahrenheit°F = 1.8 x °C +32inversely°C = (°F -32) / 1.8

ABS: Acrylonitrile-Butadiene-Styrene - plastic known for its toughness, impactstrength, dimensional stability, lightweight, and surface appearance. Also used intelephones, appliances, and automobile interiors.

ACCA: Air Conditioning Contractor of America, a national trade associationwhich represents heating, ventilation, air conditioning, and refrigeration contractors.

Accuracy: Closeness of a reading or indication of a measurement device tothe actual value of the quantity being measured.

ARI: Air Conditioning and Refrigeration Institute. ARI standards establish rating criteria and procedures for measuring and certifying comfort productperformance.

ASHRAE: American Society of Heating, Refrigeration, and Air-ConditioningEngineers.

ASTM: American Society for Testing and Materials.

Acceptable Air Quality: Air in which there are no known contaminants at harmful concentrations and with which a substantial majority (usually 80percent) of the people exposed do not express dissatisfaction (ASHRAE 1989-62).

Air Conditioning: The process of treating air to meet the requirements of aconditioned space by controlling its temperature, humidity, cleanliness, anddistribution (ASHRAE 1989-62).

Air Handler System: A mechanical system that heats and/or cools air.

Ambient Air: The air surrounding an object

Ambient: The conditions surrounding the instrument (temperature, humidity, etc.)

Ambient Operating Range: Range in the ambient temperature and relativehumidity over which the instrument is designed to operate.

Bimetal Thermometry: The principal on which bimetallic thermometerswork is that a metal changes volume with temperature and that the amount ofchange is not the same for all metals. Thus, by banding two metal strips togetherto form a coil, the coil’s movement will correspond to temperature change.

Blackbody: A theoretical object that radiates the maximum amounts of energyat a given temperature, and absorbs all the energy incident upon it. (The nameblackbody was chosen because the color black is defined as the total absorptionof light energy). Used in testing calibration of infrared thermometers.

Calibration: Comparing an instrument’s measurement against a known standard.

Calibration Procedure: A procedure to determine and set the parametersaffecting an instruments performance in order to ensure its designed functionwithin prescribed limits.

Capillary: A tube with a small bore connecting the sensor to the meter.

Celsius (Centigrade): A temperature scale defined by 0°C at the ice point and100°C at the boiling point of water at sea level.

Clear: To restore a device to a prescribed initial state, usually the zero state.

Cold Junction: The point at which thermocouple wires are joined inside the meter.

Comfort Factors: Conditions other than indoor air contaminants that causestress, comfort, and/or health problems (e.g., humidity extremes, drafts, lackof air circulation, noise, and overcrowding).

Compressor: The main component of an air conditioner or heat pump system. The compressor creates pressure to maintain the flow of refrigerant.

Condenser Coil: The coil that is located after the compressor in an air conditioning or refrigeration system. This coil is used to remove heat from a refrigerant in its compressed gaseous state.

Condensation: Water that is removed from air as it is being cooled.

Conditioned Air: Air that has been heated, cooled, humidified, or dehumidified to maintain an interior space within the “comfort zone”. (Can be referred to as “tempered air”.)

Control Point: Temperature at which a system is to be maintained.

Cooling Coil: A heat transfer device which absorbs heat.

Cooling Load: The rate of energy removal from a given space or material.

Cooling Tower: A device which cools water by evaporating a portion of it inthe air. Water is cooled to the wet bulb temperature of the air.

D:S (Distance to Spot Ratio): Optical resolution expressed as a ratio of thedistance to the resolution spot divided by the diameter of the spot.

Data/Temperature Hold: The ability to freeze the display on any givenmeasurement. Useful in applications where the instrument is not easily read while a measurement is being made.

Delta: Represents the difference between two temperatures: i.e., higher temperature minus lower temperature. Delta is the difference.

Diffusers and Grilles: Components of the ventilation system that distributeand diffuse air to promote air circulation in the occupied space. Diffuserssupply air and grilles return air.

Display Indications:

bar Pressure in bars

°C Temperature in Celsius

CL Clear min/max memory

°F Temperature in Fahrenheit

Flashing HHH/HI Shorted probe or above maximum temperature (DM120 and DM450 series)

Flashing LLL/LO Open probe or below minimum temperature (DM120 and DM450 series)

Flashing Temp Alarm condition (PM200 series, PM400K no alarms)

HI Temperature is above 300°F/150°C or shorted probe

Kgf/cm2 Pressure is in kilograms per square centimeter

LO Temperature is below -40°F/-40°C, open probe or probe is not plugged in

LO-P Battery is discharged

PSI Pressure in pounds per square inch

%RH Relative humidity measurement

SCAN Multi-channel data collection mode

W Bulb Wet bulb temperature

1, 2 or 3 Zone being monitored

29

Emmissivity: The ratio of energy emitted by the surface of an object to the energy emitted by a blackbody at the same temperature.

Environment: The surroundings in which an operation is carried out including the buildings, facilities, stationary and moveable equipment, personnel, raw materials, utensils, ingredients and other materials that areused in the process.

Evaporator Coil: Also called the cooling coil. Refrigerant is pumped through this coil and changes state from a gas to a liquid. The part of aAC/Refrigeration system where cooling or the conditioned air takes place.

Exhaust: In a HVAC context, air exiting a room through a duct.

Fahrenheit: A temperature scale defined by 32°F at the ice point and 212°Fat the boiling point of water at sea level.

Freezing Point: The temperature at which the substance goes from the liquid phase to the solid phase.

HACCP: Hazard Analysis Critical Control Points, is a quality safety system thatfocuses on the process of food in an operation to reduce risk.

HARDI: Heating, Air Conditioning & Refrigeration Distributors International

HVAC/R: Heating, ventilating, air-conditioning, and refrigeration.

Heat Pump: A type of heating unit that extracts heat from the outside air, andtransports it inside to the air handler coil.

Hygrometer: An instrument used in measuring humidity.

Ice Point: A comparison of values from a temperature measurement deviceto a more accurate device, where the medium is at a reference of 32°F (0°C).

Ice Slurry: Used in calibrating thermometers. A mixture of crushed ice andwater. This brings the temperature to 32°F (0°C) for low-end calibration.

Infrared Thermometer: An instrument that determines the temperature of an object by means of detecting and quantifying the infrared radiation emitted from the object.

Infrared: A range of the electromagnetic spectrum extending beyond red visible light from 760 nanometers to 1000 microns. Infrared is the form ofradiation used for making non-contact temperature measurements.

J-Type Thermocouple: The two thermocouple wires that are made of Iron and Copper-Nickel.

K-Type Thermocouple: The two thermocouple wires that are made ofNickel Chromium and Nickel Aluminum.

LCD, Liquid Crystal Display: A common type of display used on manyhandheld instruments and electronic products. LCD’s are constructed of twothin transparent layers with grooves filled with a polarizing liquid.

LED, Light Emitting Diode: A semiconductor diode that emits light whenvoltage is applied.

Maximum Operating Range: The maximum temperature at which aninstrument or sensor can be safely operated.

Min/Max/Average: Some instruments will record the minimum and maximum temperature and give the average temperature reading based on the min and max.

NIST: National Institute of Standards and Technology, USA

NIST Traceability: Calibration in accordance with and against standardstraceable to NIST. Traceability to NIST is a means of ensuring that referencestandards remain valid and their calibration remains current.

NSF: (NSF International) Formerly the National Sanitation Foundation, is bestknown for its role in the development of standards and criteria for equipment,products and services that bear upon health. The NSF mark is widely recog-nized as a sign that the article complies with the applicable NSF standard.

Ohm: The basic unit of resistance, specified as equal to that of a conductor in which one amp of current is produced by one volt of potential across its terminals.

Positive Pressure: Condition that exists when more air is supplied to aspace than is exhausted, so the air pressure within that space is greater than in surrounding areas.

Pressure Drop: A term used to characterize the reduction in air pressure from the compressor discharge to the actual point of use.

Range: The full scale value for a specific instrument setting.

Reheat: The application of sensible heat to supply air that has been previouslycooled below the temperature of the conditioned space by either mechanicalrefrigeration or the introduction of outdoor air to provide cooling.

Resolution: The smallest unit that can be detected and displayed by a measurement device.

Return: In an HVAC context, air exiting a room through a duct.

RH: Relative Humidity in % as opposed to absolute humidity which is in ppm. 100% RH means at that particular temperature, the air cannot absorbany more humidity and any additional amount will become water. As the temperature increases, the % RH drops hence allowing more water to be absorbed.

Refrigerant Lines: Also referred to as the vapor and liquid lines, these copper lines facilitate the flow of refrigerant within an air conditioning orrefrigeration unit.

Spirit Filled: A glass tube that uses an alcohol or petroleum liquid insideinstead of mercury.

Storage Temperature Range: The ambient temperature range an instrument can survive in non-operating mode and perform within specifications.

Super Heating: The heating of a liquid above its boiling temperature without the formation of the gaseous phase. The heating of the gaseous phase considerably above the boiling point temperature improves the thermodynamic efficiency of a system.

Superheat: The difference between the saturated temperature and the actual vapor temperature.

Supply: In HVAC terms, air which blows out of ducts into a room.

Temperature Error: The difference between the actual temperature and thetemperature measured by an instrument.

Thermistor: A semiconductor device whose resistance changes with the temperature.

Thermocouple: Has a voltage output proportional to the difference in tem-perature between the hot junction and the lead wires (cold junction).

Thermometer: An instrument that measures temperature.

UL, Underwriters Laboratories: An independent testing agency thattests products for safety and performance.

Unitary Air Conditioning Equipment: A unitary air conditioner consists of one or more factory-made assemblies which normally include an evaporator or cooling coil, an air moving device, and a compressor andcondenser combination.

Volt: The electrical potential difference between two points in a circuit. Onevolt is the potential difference needed to cause one amp of current to passthrough one ohm of resistance.

Variable Air Volume System: Air handling system that conditions the air to aconstant temperature and varies the outside airflow to ensure thermal comfort.

Ventilation: The process of supplying and removing air by natural ormechanical means to and from a space. Such air may or may not be conditioned (ASHRAE 62).

Ventilation Air: Defined as the total air, which is a combination of the airbrought into the system from the outdoors and the air that is being recirculated within the building.

Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: [email protected] • cooper-atkins.com

Distributed by: