Fire product catalogue2008
Fire
Fire product catalogue 2008
Contents
Conventional1-7 FX2200CF Range
Conventional panelsConventional detectorsAncillary devices
8-12 FX2200BWCF RangeBi wire panelsBi wire detectorsBi wire ancillary devices
Analogue13 CF3000 Range
Analogue panels
14 CF2000 RangeAnalogue panels
15 CF1000 RangeAnalogue panels
16 CF3000PRGAnalogue repeater panel
17-19 System Configuration
20 DetectionAnalogue sensors
21-26 AncillariesCallpointsSoundersAudio visual unitsBeaconsInterfacesPCBs
1
FX2200CF Range
Conventional panelsThe FX2200CF range of conventional panels provide asimple yet effective installer and end user conventionalfire detection system solution. Available as 2, 4 and8-zone panels, with the 8-zone panel being configuredfor the provision of a repeater panel output as well astwo additional alarm line outputs.
Features
> BOSEC 3rd party approved to EN54 pts. 2 and 4
> Choice of 2, 4 and 8-zone panels
> Single 12 V DC battery requirement for 24-hour standby
> Single keypad access code for end user and engineer use
> Selectable fire/fault relay
> Class change facility
> Supports up to 32 detectors on each zone
> ‘Same style’ repeater panel available for 8-zone panel
> Simple ‘one shot’ end user test facility
> Maintenance free poly switch circuit protection
Technical Specifications
Model FX2202CF FX2204CF FX2208CF
Standards EN54-2: 1998 & EN54-4: 1998 EN50130-4: 1996 EN500081-1: 1992 & EN61000-2-2: 1994Number of zones 2 4 8Detectors per zone 32Number of alarm circuits 2 4Alarm circuit load 150mA per circuit 0.3A total 400mA per circuit 0.8A total 500mA per circuit 2A totalEnd of line devices Detection circuits: EOLM1 monitoring unit. Alarm lines: 6.8K resistorAuxiliary fire signal 5A 24V DC single pole/ fault output changeover contactsAuxiliary DC output 24V DC fused. 30mARepeater port No YesMains input voltage 230V AC –10% +15%System operating voltage 24V DCStandby duration 24 hoursBattery (sealed lead acid) 1 x 3.2 AH 2 x 3.2 AHRecharge period 24 hoursPanel construction Polycarbonate housing & back boxCable entries Top: 12 x 20mm entries with blanking plugs
Rear cable entry apertureEnvironmental rating IP30. -5°C to +40°C humidity 75% max (non condensing)Surface dimensions WxHxD (mm) 332 x 270 x 90mm
Product Codes
FX2202CF 2-Zone panelFX2204CF 4-Zone panelFX2208CF 8-Zone panelFXRP2200CF Repeater panel
2
FX2200CF Range
Conventional detectorsA comprehensive range of conventional detectors areavailable for the FX2200CF range of fire detection panels.
Features
> LPCB 3rd party approved
> Low profile design
> 360° viewable LED design
> Removable detector chamberfor cleaning
> Common mounting base
CPD321* CPT341** CFR330
CHT390CMT360 CDBB300 CIR301
Technical Specifications
Model CPD321* CPT341** CFR330 CMT360 CHT390
Description Photoelectric Photo Thermal Heat Detector Heat Detector Heat DetectorSmoke Detector Smoke Detector (Fast Response) (Medium Response) (High Temperature)
Standards EN54 pt7:2000 and EN54 pt7:2000, EN54 pt7:2000BSEN54 pt7:2001 BSEN54 pt7:2002 and and BSEN54 pt5:2001
BSEN54 pt 5:2001Area coverage 100m2 (subject to local standard) 50m2 (subject to local standard)System wiring 2 coreIndication 360˚ visibility pipeMounting Surface mount using CDBB300Compatibility FX2200CF range of panelsDetection mode Light scatter principle Light scatter principle & Heat sensitive element
heat sensitive elementOperating voltage 15V to 30V DCMax stand-by current 30 µA 220 µA 30 µAMax start up current 210 µA 340 µA NAMax alarm current 25 mA 20 mA 25 mAAlarm temperature NA 60˚C 77˚C 92˚CHeat class NA A2S A1R BS CSEnvironmentalApplication Indoor use IP40Temperature -20˚C to 60˚CHumidity 0 - 95% non condensingEMC CE markedConstructionMaterial PC/ABSColour WhiteDimensionsExcluding base 100mm(Dia) x 43mm(H)Including base 100mm(Dia) x 45mm(H) 101mm(Dia) x 55mm(H)
Product Codes
CPD321* Photoelectric smoke detectorCFR330 Heat detector fast response (A1R)CHT390 Heat detector high temperature (CS)CIR301 Remote indicator
CPT341** Photo thermal ‘dual’ detectorCMT360 Heat detector medium response (BS)CDBB300 Common base
* Previous code CPD320** Previous code CPT340
33
FX2200CF Range
Ancillary devicesCallpoints – CX201 and CX203
> Design approved to EN54 -11
> Convenient clip fixed front cover
> One key for test and cover removal
> Available as flush, surfaceand weatherproof (IP65)
Bells
> High sound output
> Low current
> 4, 6 and 8-inchversions available
CFB6D24CFB4D24Technical Specifications
Model CFB4D24 CFB6D24 CFB8D24
Operating voltage 18 to 30V DCSound output 84dB(A) at 12V DC 93-95dB(A) at 24V DC 95-97dB(A) at 24V DCCurrent consumption 20mA at 24V DC 25mA at 24V DC 28mA at 24V DCOperating temperature -10°C to +55°CConstruction - Gong Steel
- Base PolycarbonateColour RedIP rating IP42Dimensions (mm) 110 (Dia) x 63 (D) 152 (Dia) x 63 (D) 203 (Dia) x 67 (D)Weight 0.45Kg 0.85Kg 1.7Kg
Product Codes
CFB4D24 4” BellCFB6D24 6” BellCFB8D24 8” Bell
Product Codes
CX201 Flush/surface callpointCX203 Weatherproof callpoint (IP67)CXPC Plastic front cover Pk of 10UBSG Spare glasses Pk of 5CXUK Call point keys Pk of 10
Technical Specifications
Model CX201 - Flush/Surface CX203 - Weatherproof
Configuration Series resistor 680ΩRating 24 V DCConnection 4-way terminal blockOperating method Glass element with safety filmTest facility Unique keyConstruction ABSIP Rating IP42 IP67Temp -25°C to +55°CDimensions WxHxD (mm) 86x86x20(S) 53(F) 110x110x65Weight 0.19Kg 0.29Kg
44
FX2200CF Range
Ancillary devicesElectronic sounders
A comprehensive range of electronic sounders,beacons and sounder/beacons are available in theCooper range.
Roshni ROLP
> Low current
> High sound output
> 32 selectable tones
> IP65 version available
> Lockable base
Symphoni
> Ultra low current
> High sound output
> 3 Tones
> Volume control
> IP65 version available
> Lockable base
ROLP-R-S ROLP-R-D
Product Codes
SY-R Symphoni sounderSY-R-IP Symphoni sounder, IP66
SY-R SY-R-IP
Technical Specifications
Model ROLP-R-S ROLP-R-D
Operating voltage 9 to 28V DCSound output (tone 3) 102dB(A) at 24V DCTones available 32Temperature -25°C to +70°CConstruction ABSColour RedIP rating IP54 IP65Dimensions (mm) 93 (Dia) x 63 (D) 93 (Dia) x 93 (D)Weight 0.24 Kg 0.3 Kg
Product Codes
ROLP-R-S Roshni sounder, shallow baseROLP-R-D Roshni sounder, deep base, IP65
Technical Specifications
Model SY-R SY-R-IP
Operating voltage 12 to 30V DCSound output 100dB(A) at 24V DCCurrent consumption 5mA at 24V DCOperating temperature -25°C to +70°CColour RedIP rating IP42 IP66Dimensions WxHxD (mm) 110x110x95 110x110x105Weight 0.58 Kg 0.68 Kg
555
FX2200CF Range
Ancillary devicesAskari
> Low current
> High sound output
> 32 tones
> Volume control
> Available in red (R) or white (W)
Squashni
> Low current
> High sound output
> 32 Tones
> Volume control
> Available in red (R) or white (W)
AC-W
SQ-W
Technical Specifications
Model AC-W (R)
Voltage 9 to 28V DCSound output 97dB(A) at 24V DCTones 32Temperature -25°C to +70°CConstruction ABSColour Red or whiteIP rating IP54 (with backbox)Dims WxHxD (mm) 86x86x42Weight 0.11Kg
Product Codes
AC-W Askari flush sounder - whiteAC-R Askari flush sounder - red
Technical Specifications
Model SQ-W (R)
Operating voltage 10 to 28V DCSound output 93dB(A) at 24V DCCurrent consumption 18mA at 24V DCOperating temperature -25°C to +70°CConstruction ABSColour White or redIP rating IP42Dimensions (mm) 112 (Dia) x 30 (D)Weight 0.15Kg
Product Codes
SQ-W Squashni base sounder - whiteSQ-R Squashni base sounder - red
666
FX2200CF Range
CS200
> Low current
> High sound output
> 32 tones
> Clip fit base
> Available in red (R) or white (W)
> Lockable base
Sounder/Beacons
Flashni
> High output sounder beacon
> Volume control
> Lockable base
Ancillary devices
Product Codes
CS200W Electronic sounder - whiteCS200R Electronic sounder - red
Product Codes
FL-RL-R-S Flashni sounder beacon, shallow baseFL-RL-R-D Flashni sounder beacon, deep base
CS200W
FL-RL-R-D
Technical Specifications
Model FL-RL-R-S FL-RL-R-D
Operating voltage 18 to 30V DCSound output 101dB(A) at 24V DCCurrent consumption 68mA at 24V DCOperating temperature -10°C to +55°CConstruction Lens - Polycarbonate, Base - ABSColour RedIP rating IP42 IP66Dimensions (mm) 93 (Dia) x 92 (D) mm 93 (Dia) x 121 (D) mmWeight 0.29Kg 0.33Kg
Technical Specifications
Model CS200W (R)
Operating voltage 10 to 28V DCCurrent consumption 16mA at 24V DCSound output 100dB(A) at 24V DCTones 32Volume control 20dB rangeOperating temperature -10°C to +55°CConstruction ABSColour Red or whiteIP rating IP21CDimensions (mm) 112 (Dia) x 30 (D) mmWeight 0.24Kg
7
FX2200CF Range
Ancillary devicesBase AV unit
> Low profile design
> High output LED beacon
> Volume control
> Can be standalone unit or with detector & base
> Tamper-proof cover for standalone use SQG3-AV-W
Technical Specifications
Model SQG3-AV-W
Operating voltage 18 to 28V DCCurrent consumption 10mA at 24V DCOperating temperature -10°C to +55°CLight output >1CdFlash rate 1HzTones 5Construction ABS FRColour WhiteIP rating IP40Dimensions (mm) 114 (Dia) x 35Weight 0.11Kg
Product Codes
SQG3-AV-W-CAP Base sounder beacon unitSQG3-COV Base sounder beacon cover Pk of 5
8
FX2200BWCF Range
Bi wire panelsThe Cooper range of Bi wire panels are designed in sucha way that there is no requirement for alarm lines to beinstalled; detectors, sounders, beacons and relays allshare the same zone wiring pair giving significant savingsin both cable and installation costs.
The 4 and 8-zone panels provide enhanced features accessedvia dip switch settings; these include non latching zones,alarm line output delay, double knock and pulsed alarmoutput facilities.
Features
> Choice of 2, 4 and 8-zone panels
> Detectors and sounders share same wiring
> Single 12 VDC battery requirement for 24-hour standby
> Single keypad access code for end user and engineer use
> Selectable fire/fault relay
> Class change facility
> Supports up to 20 detectors and 20 sounders,beacons or relays on each zone
> ‘Enhanced’ features available on 4 and 8-zone panels
> Maintenance-free poly switch circuit protection
Technical Specifications
Model FX2202BWCF FX2204BWCF FX2208BWCF
Standards EN54-2: 1998 & EN54-4:1998 EN50130-4: 1996 EN500081-1: 1992 & EN61000-2-2: 1994Number of zones 2 4 8Detectors per zone 20Alarm circuit load 150mA per zoneEnd of line devices Active end of line monitoring unitAuxiliary fire signal / fault output 1A 24V DC single pole changeover contactsMains input voltage 230V AC –10% +15%System operating voltage 24V DCStandby duration 24 hoursBattery (sealed lead acid) 1 x 3.2 AH 12V 2 x 3.2 AH 12VRecharge period 24 hoursPanel construction Polycarbonate housing & back boxCable entries Top: 12 x 20mm entries with blanking plugs.
Rear cable entry aperture.Environmental rating IP30. -5°C to +40°C Humidity 75% max (non condensing)Surface dimensions WxHxD (mm) 332 x 270 x 92
Product Codes
FX2202BWCF 2-Zone panelFX2204BWCF 4-Zone panelFX2208BWCF 8-Zone panel
9
Bi wire detectorsA comprehensive range of conventional detectors areavailable for Bi wire range of fire detection panels.
Features
> LPCB 3rd party approved
> Low profile design
> 360° viewable LED design
> Removable detector chamberfor cleaning
> Common mounting base
CXN623 CXN622 CXN625
CXN626CXN624 CDBB300 CIR301
FX2200BWCF Range
Technical Specifications
Model CXN623 CXN622 CXN625 CXN624 CXN626
Description Photoelectric Photo Thermal Heat Detector Heat Detector Heat DetectorSmoke Detector Smoke Detector (Fast Response) (Medium Response) (High Temperature)
Standards EN54 pt7:2000 & EN54 pt7:2000, EN54 pt7:2000BSEN54 pt7:2001 BSEN54 pt7:2002 & & BSEN54 pt5:2001
BSEN54 pt 5:2001Area coverage 100m2 (subject to local standard) 50m2 (subject to local standard)System wiring 2 coreIndication 360˚ Visibility pipeMounting Surface mount using CDBB300Compatibility FX2200BWCF range of panelsDetection mode Light scatter principle Light scatter principle & Heat sensitive element
heat sensitive elementOperating voltage 15V to 30V DCMax stand-by current 30 µA 70 µA 30 µAMax start up current 210 µA 340 µA NAMax alarm current 25 mA 20 mA 25mAAlarm temperature NA 60˚C 77˚C 92˚CHeat class NA A2S A1R BS CSEnvironmentalApplication Indoor use IP40Temperature -20˚C to 60˚CHumidity 0 - 95% non condensingEMC CE markedConstructionMaterial PC/ABSColour WhiteDimensionsIncluding Base (mm) 104 (Dia) x 47 (H) 101 (Dia) x 56 (H)
Product Codes
CXN623 Photoelectric smoke detectorCXN625 Heat detector fast responseCXN626 Heat detector high temperatureCIR301 Remote indicator
CXN622 Photo thermal ‘dual’ detectorCXN624 Heat detector medium responseCDBB300 Common base
10
FX2200BWCF Range
Bi wire ancillary devicesCallpoints – CX201 and CX203
> Design approved to EN54 -11
> Convenient clip fixed front cover
> One key for test and cover removal
> Available as flush, surfaceand weatherproof (IP65)
Electronic sounder
> Ultra low current
> High sound output
> Volume control
> Lockable base
Product Codes
CX009 Electronic sounder
CX009
Technical Specifications
Model CX201 - Flush/Surface CX203 - Weatherproof
Configuration Series resistor 680ΩRating 24 V DCConnection 4-way terminal blockOperating method Glass element with safety filmTest facility Unique keyConstruction ABSIP Rating IP42 IP67Temp -25°C to +55°CDimensions WxHxD (mm) 86x86x20(S) 53(F) 110x110x65Weight 0.19Kg 0.29Kg
Product Codes
CX201 Flush/surface callpointCX203 Weatherproof callpoint (IP67)CXPC Plastic front cover Pk of 10UBSG Spare glasses Pk of 5CXUK Call point keys Pk of 10
Technical Specifications
Model CX009
Operating voltage 12 to 30V DCSound output 100dB(A) at 24V DCCurrent consumption 5mA at 24V DCOperating temperature -25°C to +70°CColour RedIP rating IP42Dimensions WxHxD (mm) 105x105x95Weight 0.28 Kg
11
Bi wire ancillary devicesDetector base sounder
> Integral detector base
> Low current
> Can be used as standalone sounder
LED Beacon
> High output LED beacon
> Low current
FX2200BWCF Range
CXN520BWS
Product Codes
CXN520BWS Base sounder
Product Codes
CXN004BW LED beacon
CXN004BW
Technical Specifications
Model CXN520BWS
Operating voltage 25 to 32V DCSound output 90dB(A) at 1 metreCurrent consumption 8mAOperating temperature -10°C to +55°CConstruction ABSColour WhiteIP rating IP40Dimensions (mm) 102 (Dia) x 40 (D)Weight 0.2Kg
Technical Specifications
Model CXN004BW
Operating voltage 18 to 30V DCCurrent consumption 68mA at 24V DCOperating temperature -10ºC to +55ºCConstruction Lens - Polycarbonate, Base - ABSColour RedIP rating IP42Dimensions (mm) 95 (Dia) x 53 (D)Weight 0.1Kg
12
FX2200BWCF Range
Bi wire ancillary devicesRelay modules
> Connects on zone wiring
> Relay operates on anyfire activation
CXN01124V CXN011230
Technical Specifications
Model CXN01124V CXN011230
Sets of contacts 1 set of change over contactsContact rating 1A (24V DC) 3A (230V DC)Colour WhiteIP rating IP40Dimensions WxHxD (mm) 150x89x58Weight 0.2Kg
Product Codes
CXN01124V Relay module 24V DC switchingCXN011230 Relay module 230V AC switching
13
Analogue panelsThe Cooper CF3000 range of panels offer ahigh-specification, analogue fire detection panel solutionwhich is available in a 1, 2 or 4-loop configuration.
It combines sophisticated functionality, yet simple paneloperation with a very aesthetically-pleasing design.
The large capacity, ability to support complex cause and effectprogramming and wide range of user-controllable functionsmake this panel suitable for a wide range of projects fromsheltered housing to large office developments as well as manyindustrial applications.
The CF3000 range of panels provide a large (120mm x 90mm)touch screen display as the main user element, eliminating theneed for dedicated system push buttons. The user interface ismenu-driven, automatically reconfiguring to suit the chosenmenu option. To enable text updates directly at the panel, thedisplay converts to a full QWERTY keyboard, enablingcomprehensive text insertion.
The panel also has 96 zone fire LEDs providing additionalinformation about the extent of any fire activation as well asa comprehensive set of system status LEDs providingadditional visual information for the end user.
The panels use ‘spur tolerant’ soft addressing to minimiseinstallation time and remove the potential for error normallyassociated with manual addressing.
All of the CF3000 fire detection system components have beenspecifically designed to operate as part of an integrated system;this provides an assurance that the panel, sensors, interfacesand other ancillaries are all fully compatible with each otherand that the full range of system functionality is supported byeach device.
Features
> LPCB 3rd party approved to EN54 pts. 2 and 4
> Choice of 1, 2 and 4-loop panel options
> Large multi functional touch screen
> Spur tolerant soft addressing
> Short circuit isolators incorporated into each loop device
> Up to 200 addresses per loop
> Fully network capable up to 127 panels
> Network compatible with CF1000 range andCF2000 range of panels
> Optional integral printer
CF3000 Range
Product Codes
CF30001G 1-Loop panelCF30002G 2-Loop panelCF30004G 4-Loop panelCF30001GP 1-Loop panel c/w integral printerCF30002GP 2-Loop panel c/w integral printerCF30004GP 4-Loop panel c/w integral printer
CF30001GNC 1-Loop panel c/w network cardCF30002GNC 2-Loop panel c/w network cardCF30004GNC 4-Loop panel c/w network cardCF30001GPNC 1-Loop panel c/w integral printer and network cardCF30002GPNC 2-Loop panel c/w integral printer and network cardCF30004GPNC 4-Loop panel c/w integral printer and network car
14
Analogue panelsThe Cooper CF2000 panel is an entry level two-loopanalogue fire detection panel which can be configuredfor 1 or 2-loop operation.
The panel has a 126mm x 64mm graphic display whichprovides a simple yet comprehensive, menu-driven, enduser interface.
With the panel’s ability to support complex cause and effectprogramming and a wide range of user controllable functions itmakes the panel suitable for a varied range of projects fromsmall warehouses to small/medium office developments as wellas many small industrial applications.
As with all Cooper analogue addressable panels, the CF2000uses ‘spur tolerant’ soft addressing to minimise installation timeand remove the potential for errors often associated with manyforms of manual addressing.
All of the CF2000 fire detection system components have beenspecifically designed to operate as part of an integrated system;this provides an assurance that the panel, sensors, interfacesand other ancillaries are all fully compatible with each otherand that the full range of system functionality is supported byeach device.
Features
> BOSEC 3rd party approved to EN54 pts. 2 and 4
> Choice of 1 or 2-loop panel operation
> Menu-driven graphic screen
> Spur tolerant soft addressing
> Short circuit isolators incorporated into each loop device
> Up to 200 addresses per loop
> Network compatible with CF1000 and CF3000range of panels
CF2000 Range
Product Codes
CF2000G 2-Loop panelCF2000GNC 2-Loop panel c/w network card
15
Analogue panelsThe Cooper CF1000 range of analogue fire detectionpanels are available as 1 and 2-loop configured panels.They provide sophisticated ‘touch screen’ functionalityyet achieve a simple end user interface operation withina compact panel design.
The CF1000 range of panels provide a large (120mm x 90mm)touch screen display as the main user element, eliminating theneed for dedicated system push buttons. The user interface ismenu-driven, automatically reconfiguring to suit the chosenmenu option. To enable text updates directly at the panel, thedisplay converts to a full QWERTY keyboard, enablingcomprehensive text insertion.
The panel also has 16 zone fire LEDs providing additionalinformation about the extent of any fire activation as well as acomprehensive set of system status LEDs providing additionalvisual information for the end user.
The CF1000 range supports a complex cause and effectprogramming ability which, together with a wide range of usercontrollable functions, makes the panel suitable for a widerange of projects.
As with all Cooper analogue panels the CF1000 range uses‘spur tolerant’ soft addressing thereby minimising installationtime and removing the potential for errors often associated withother forms of system addressing.
As with the entire range of Cooper analogue panels, theCF1000 range of panel system components have beenspecifically designed to operate as part of an integrated system;this provides an assurance that the panel, sensors, interfacesand other ancillaries are all fully compatible with each otherand that the full range of system functionality is supported byeach device.
Features
> Large versatile touch screen display
> 1 and 2-loop panel versions
> Spur tolerant soft addressing
> Short circuit isolators incorporated into every loop device
> Up to 200 addresses per loop
> Network capable with CF3000 and CF2000 rangeof panels
> Integral power supply
> Large selection of compatible ancillaries
CF1000 Range
Product Codes
CF1100 1-Loop panelCF1100NC 1-Loop panel c/w network cardCF1200 2-Loop panelCF1200NC 2-Loop panel c/w network card
16
Analogue repeater panelThe Cooper analogue system repeater panel is availableas a loop-connected panel (CF3000PRG)or as a network-connected panel (CF3000PRGNC).
When connected to a panel loop, the host panel textinformation is downloaded manually at time of systemcommissioning using ‘site installer’ software. If the repeater isnetwork connected all text is transmitted via the network andis automatically updated should any changes be made toany of the network panels.
Both repeater panels are fully compatible with the extensiverange of Cooper analogue panels.
Features
> 2x40 backlit LCD display
> Loop or network connected
> Silence alarm, evacuate and resetcommands from repeater
CF3000PRG Range
Product Codes
CF3000PRG Loop-connected repeater panelCF3000PRGNC Network-connected repeater panel
Loop connected Network connected
Mains Supply
MainsSupply
Mains Supply
17
The Cooper analogue control panel system architecturehas been designed in such a way that future systemexpansion, within a single-panel solution or as part of amulti-panel network, can be achieved with a minimumamount of system downtime.
Soft Addressing
The system ‘auto learn’ facility, once activated on initial panelstart up, will scan each loop and allocate an address numberto each loop device thus providing a simple yet efficient setupprocedure which alleviates the need for time consuming manualdevice addressing and minimises potential problems due todual addressing. Each loop device has integral short circuitisolators ensuring maximum loop integrity should a short-circuitfault occur on the loop wiring.
Detection Capacity
Up to 200 addresses per loop can be installed, which can be amixture of callpoints, sensors, beam detectors, interfaces, loopsounders or repeater panels. It should be noted that, to complywith EN54 requirements no more than 512 addresses should beconnected to a single panel.
Alarm Capacity
Up to 80 loop-powered sounders, beacons, sounder beaconsor interfaces can be connected per loop. With a full range ofconventional sounders and beacons, up to a total load of 1.5Acan be connected via the control panels four alarm line outputs.Alternatively additional conventional sounders can be connectedvia a CSC354 loop mounted 4-way sounder controller unitremotely from the panel.
Interfaces
An extensive range of interfaces are available for theCooper range of analogue panels providing solutionsfor most design requirements.
> Spur isolator available to allow loop spurs of analogueaddressable devices
> 3-way 24V rated input / output unit suitable for switchinglow voltage control equipment
> Zone monitor unit, to connect zones of suitable conventionaldetectors or loop-powered beam detectors
> Mains rated Input / output unit for switching mainsoperated equipment
> Sounder circuit controller provides four additional,programmable, conventional sounder circuits remote fromthe main control panel
> Shop unit isolator allows the connection of a conventionaldetection zone along with two conventional soundercircuits, ideal for linking small self-contained units ontoa main addressable panel. The interface requires a 24 vdcpower supply.
System Networking
The full range of Cooper analogue panels can benetworked together. When fitted with a network card, up to126 panels and repeaters can be networked to form a singleco-ordinated system.
With larger networked systems, where long distances arefound, it is possible to connect networks using LON boosters,fibre optic interfaces or IP routers.
When operating as a network system fire, fault and pre-alarminformation is transmitted across the network, as well as textinformation, with evacuate, silence alarm and reset controlfunctions also permitted across the network. Networkconfiguration of the system, to permit or inhibit each signal orfacility, is achieved using the engineering menu on each panel.
Site Monitor/Graphics
Cooper Site Graphic is a versatile alarm management systemproviding a comprehensive site monitoring and control packageof the installed fire detection system that interfaces to thenetwork of the Cooper range of analogue panels using anetwork manager driver program. The site graphics dedicatedPC is connected to the network via an EC0232 board.
System Configuration
System configuration
18
Typical application schematic
System Configuration
Loops 2-4if fited
Fire ornon-fire input
Mains-ratedoutput relaycontact
3 separate inputsto accept fire ornon-fire inputs
Zone of compatibleconventional callpoints
and detectors
Zone of compatibleconventional callpointsand detectors
2 circuits ofconventional
sounders
Spur ofanalogue devices
3 independentvolt-freeoutput contacts
MainsSupply
MainsSupply
MainsSupply
Repeater
CSC354
CF3000 CSUM355
CSI350
CZMU352
CMIO353 CIO351
4 independentlycontrolled conventional
sounder circuits
19
System Configuration
Technical Specifications
Panel type CF3000 CF2000 CF1100 CF1200
Standards EN-54:2 1998 & EN54:4 1998 EN-501304Number of loops CF30001 – 1 loop
CF30002 – 2 loops 2 1 2CF30004 – 4 loops
Addresses per loop 200Panel sounder circuits 4 outputs (programmed in pairs - outputs 1&2, 3&4) 2Class change facility Operated by external, normally open, volt free contactsAuxiliary relay One set of change over contacts, operated in the event of fire activationAuxiliary fire routing Monitored 24 V DC, 30 mA (max)equipment outputAuxiliary fire protection Monitored 24 V DC, 30 mA (max)equipment outputAuxiliary fault routing Monitored 12 V DC, 30 mA (max)equipment outputOutput ports RS485 and RS232 (for connection of repeaters etc)Mains input voltage 230 V AC +10% / -15%System operating voltage 24 V DCBattery 2 x 12 V 12Ah 2x 12 V 7Ah 2x12 V 7AhStandby duration 24 hours (dependant on loop loading)Cable entries 31 top entry cable knockouts 20 top entry cable knockouts 11 top entry cable knockouts (20mm)
(20mm) & 12 rear cable entry (20mm) & 7 rear cable entry plus rear entry cable aperturecable knockouts (20mm) cable knockouts (20mm)
Environmental rating IP30, -5ºC to +40ºC, 75% RH (non condensing)Colour GraphiteSize WxHxD (mm) 395x495x125 400x320x170 375x357x50Weight 18Kg 15Kg 8Kg
Repeater Panel
Panel type CF3000PRG and CF3000PRGNC
Display 2x40 Character Backbit LCDSystem indicators Power on, fire, fault, test, disable and scrollSystem controls Silence alarms, evacuate and resetInput ports RS232 (for connection of programmer)Mains input voltage 230 V AC +10% / -15%System operating voltage 24 V DCBattery 1 x 12 V 3.2AhStandby duration 24 hours (dependant on loop loading)Mechanical PC/ABS, rating - UL94V0Environmental rating IP30, 0ºC to 25ºC, 75% RH (non condensing)Colour Light greySize WxHxD (mm) 332x270x92Weight 3.6KgCompatibility CF3000, CF2000, CF1100 and CF1200
20
Detection
Analogue sensorsA comprehensive range of analogue sensors areavailable to operate with the Cooper analogueaddressable panel range with the following :-
Features
> Stylish low profile design
> 360º viewable LED design
> Removable detector chamber
CAP320 – Photoelectricsmoke sensor
CAPT340 – Photo-thermal smoke sensor
CAH330 – Multi-modeheat sensor
CAB300Common base
CIR301Remote indicator
Technical Specifications
Model CAP320 CAPT340 CAH330
Specification EN54 pt7:2000 and BSEN54 EN54 pt7:2000 and EN54 EN54 pt5:2000 and BSEN54pt7:2001 pt5:2000BS, BSEN54 pt7:2001 pt5:2001
and BSEN54 pt 5:2001Area coverage 100m² (subject to local standard) 50m² (subject to local standard)System wiring Min. 1.5mm, 2 core loop or spurIndication 360° visibility light pipeMounting Surface mount CAB300 baseCompatibility CF range of analogue panelsAddressing mode Auto addressOperating voltage 18 to 30V DCMax standby current 220µAMax alarm current 5mAHeat classRate of rise na A1S A1RFixed 60ºC na na BSFixed 90ºC na na CSAlarm temperature (static)AIR na 60ºC 60ºCBS na na 77ºCCS na na 90ºCEnvironmentalApplication Indoor use IP 40Temperature -20°C to 60°C -20°C to 50°C -20°C to 60°CHumidity 0 to 95% non condensingConstructionMaterial PC/ABSColour WhiteDimensions(excl.base) (mm) 101 (Dia) x 33 (H) 101 (Dia) x 43 (H) 101 (Dia) x 43 (H)(incl.base) (mm) 104 (Dia) x 45 (H) 104 (Dia) x 55 (H) 104 (Dia) x 55 (H)Weight 76g (without base)
Product Codes
CAP320 Optical sensorCAPT340 Photo thermal ‘Dual’ sensorCAH330 Heat sensorCAB300 Analogue sensor baseCIR301 Remote indicator
21
Ancillaries
Addressable callpointsThe Cooper range of addressable callpoints are availableas surface, flush and weatherproof versions.All callpoints have integral short circuit isolators and havea status LED fitted as standard. To simplify replacementof glass element callpoints are fitted with fast fit clip onfront covers.
CBG370Flush
CBG370-SSurface
CBG370-WPWeatherproofTechnical Specifications
Model CBG370 CBG370-S CBG370-WP
Type Flush Surface WeatherproofConfiguration AddressableRating 24V DCConnections 4-way terminal blockOperating method Glass element with plastic safety film or resetable plastic element
with integral alarm indicatorTest/reset facility Unique keyConstruction ABSColour Red to EN54-11IP rating IP42 IP67Temp. range -10°C to +55°CDimensions HxWxD (mm) 87x87x20 87x87x53 110x110x65Weight 0.15Kg 0.2Kg 0.3Kg
Product Codes
CBG370 Callpoint-flushCBG370-S Callpoint-surfaceCBG370-WP Callpoint-weather resistantCXPC Polycarbonate cover (pk of 10)UBSG Spare glass (pk of 5)CXUK Spare callpoint key (pk of 10)
22
Ancillaries
Addressable soundersBase sounder
The CAS380 is a loop-powered integrated sounder andsensor mounting base. It can be used with any analoguesensor or as a standalone sounder with the optionalCASC cover plate.
Wall sounder
The CAS381 range of loop-powered addressable wallsounders offers a highly efficient, low current sounderoption. Sounder volume and tone are set at the analoguepanel avoiding the need to access each sounderindividually to alter settings.
CAS380
CAS381Wall sounder
CAS381-WPWall sounder IP65
Technical Specifications
Model Number CAS380 CAS381 CAS381/WP
Model Base sounder Wall sounder Wall sounder - weatherproofOperating voltage 17 to 32 V DCTones (set by panels) Continuous 910Hz Continuous 910Hz
Pulsed 910 / 0Hz @ 1Hz Pulsed 910 / 0Hz @ 1HzTwo tone 610 / 910Hz @ 1Hz cycle Two tone 644 / 984Hz @ 1Hz cycle
Slow whoop Slow whoop 500-1200Hz in 3.5 sec / 0.5 sec gapSound output (set by panel) Low volume: 84 dB Low volume: 87 dB+/- 3 dB Medium volume: 92 dB Medium volume: 93 dB
High volume: 95 dB High volume: 100 dBCurrent consumption Low volume: <2mA
Medium volume: <3mAHigh volume: <6mA
Standby current <320µAOperating temperature -10°C to +55°C (95% RH)Construction ABSColour White Red RedIP rating IP40 IP42 IP66Dimensions HxWxD (mm) 102 (Dia) x 40 (D) 105x105x95 108x108x103Weight 0.2Kg 0.25Kg 0.57Kg
Product Codes
CAS380 Base sounderCAS381 Addressable wall sounderCAS381-WP Addressable wall sounder
- weatherproofCASC Pk of 5 base sounder covers
23
Ancillaries
Audio visual unitsIntegrated sounder beacons
The CASB range of loop-powered addressable wallsounder beacons offer a highly efficient, low currentsounder beacon option. Sounder volume and tone are setat the analogue panel avoiding the need to access eachsounder individually to alter settings. CASBB384
Sounder beacon baseCASB383
Sounder beaconCASB383-WPIP65 version
Technical Specifications
Model CASBB384 CASB383 CASB383-WP
Operating voltage 17 to 32V DCTones (set by panels) Continuous 910Hz Continuous 910Hz
Pulsed 910 / 0Hz @ 1Hz Pulsed 910 / 0Hz @ 1HzTwo tone 610 / 910Hz @ 1Hz cycle Two tone 644 / 984Hz @ 1Hz cycle
Slow whoop Slow whoop 500-1200Hz in 3.5 sec / 0.5 sec gapSound output (set by panel) +/- 3 dB Low volume: 77 dB Low volume: 87 dB+/- 3 dB Medium volume: 89 dB Medium volume: 93 dB
High volume: 90 dB High volume: 100 dBCurrent consumption Low volume: <7mA
Medium volume: <8mAHigh volume: <9mA
Standby current <320µAOperating temperature -10°C to +55°C (95% RH)Construction PC ABSColour White RedIP rating IP40 IP42 IP66Dimensions HxWxD (mm) 115 (Dia) x 42 (D) 105x105x95 108x108x103Weight 0.2Kg 0.25Kg 0.57Kg
Product Codes
CASBB384 Base sounder beaconCASB383 Wall sounder beaconCAS383-WP Wall sounder beacon
- weatherproofCASC Pk of 5 base sounder
beacon covers
24
Ancillaries
BeaconsLED beacon
The CAS382 loop-powered addressable beacon offershigh efficiency LED technology together with a low profiledesign for a discreet installation. The beacon is designedto provide a visual indication in areas of high ambientnoise or where people may be hard of hearing.
Technical Specifications
Model CAB382
Operating voltage 17- 32V DCStandby current <250µACurrent consumption <4.1mAOperating temperature -10°C to +55°CFlash frequency 1/2 HzConstruction Lens - polycarbonate, base - ABSColour RedIP rating IP54Dimensions (mm) 95 (Dia) x 53 (D)Weight 0.15Kg
CAS382LED beacon
Product Codes
CAS382 LED beacon
25
Ancillaries
InterfacesAn extensive range of interfaces are available for theCooper range of analogue panels providing solutions formost design requirements.
> CSI350 spur isolator available to allow loop spurs of analogueaddressable devices
> CIO351 3-channel 24V-rated input / output unit suitable forswitching low voltage control equipment
> CZMU352 zone monitor unit, to connect zones of suitableconventional detectors or loop powered beam detectors
> CMIO353 mains-rated input / output unit for switching mainsoperated equipment
> CSC354 Sounder circuit controller provides four additional,programmable, conventional sounder circuits remote fromthe main control panel
> CSUM355 shop unit isolator allows the connection of aconventional detection zone along with two conventionalsounder circuits, ideal for linking small self contained unitsonto a main addressable panel. The interface requires a24 vdc power supply
A range of micro interfaces modules are also available:
> MCIM is a compact input module used to accept inputsignals from external equipment such as beam detectors,flow switches, valve monitor switches etc
> MCIM-C is a compact input module configured to berecognised by the analogue panel as a callpoint
> MCOM is a compact output module used to control orsignal external equipment such as access control systems,lift positioning etc
> MCOM-S is a compact input module configured to berecognised by the analogue panel as a sounder
CSI350Spur Isolator unit
CIO3513 Channel I/O unit
CZMU352Zone monitor unit
CMIO353230V Relay I/O unit
CSC3544 Way sounder controller
CSUM355Shop unit monitor
MCIMSingle input module
MCOMSingle output module
MCIM MCOM
26
Ancillaries
PCBsMimic PCB
> Available as master or slave. Each has 32 outputs
> 96 outputs (1 master + 2 slaves)
> Ideal for mimic panel provision
> Two types available:- LED or relay output
> Each output can be programmed as fire or fault
> Each output can be operated by address, zone orpanel activation
4 to 20mA Interface
> Addressable interface with built in isolator
> Ideal interface for gas detectors
> Uses one address
> Program 3 level of sensitivity using dip switch
> 3 volt free outputs for each of the three alarm levels
> Tracking/enabling facility (in tracking mode CF3000 willdisplay pre-alarm 1, pre-alarm 2 & alarm). In alarmcondition,CF3000 cause & effect programming is enabled
> Requires external power supply (PSU is opto isolatedfrom CF3000 loop)
> The supply to the gas detector is taken directly fromthe interface
LED Repeater PCB
> Can be loop connected or network connected
> Each LED can be programmed to operate by zone orby address for fire or fault indication using PC repeaterdownload software
> Up to 5 different zones can be programmed per LED
> General fire, fault, local power fault & system faultLED provision
> Test lamp button
Loop splitter unit
> Unit is loop connected
> Splits each connected loop into 4 smaller loops(max 50 devices per loop)
Master & slave LED output PCB
4 to 20mA Interface 4 to 20mA Interfacewith relay outputs
Master & slave relay output PCB
Loop splitter PCB
27
Notes
28
Conditions of saleAll goods supplied are subject to the company’s generalconditions of sale which are available on request.
Trade DescriptionsAll descriptions represent only particulars of the goods to whichthey apply and do not form part of any contract. The companyreserves the right to change specification without prior notificationor public announcement.
®2008 CooperAll rights reserved.
Publication Ref: CLSF042008April 2008
All Cooper logos are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use Cooper trademarkswithout the prior written consent of Cooper Industries.
SalesT: +44 (0)1302 303 303 (Option 2)F: +44 (0)1302 367 155E: [email protected]