Corrosion and Accelerated Testing Rob Sorensen 505-844-5558 [email protected] Sandia National Laboratories Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000.

Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . [email protected] . Sandia National Laboratories Sandia is a multiprogram laboratory operated

  • Upload
    lamnga

  • View
    220

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Corrosion and Accelerated Testing

Rob Sorensen 505-844-5558 [email protected] Sandia National Laboratories

Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000.

Page 2: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

What is corrosion?

Aqueous (general & localized attack) • electrochemical • oxidation / reduction

Atmospheric • gas-metal reaction (slow) • condensed phase

electrochemical • pollutant gasses (ppt levels of H2S, NO2, Cl2 …)

Environmental degradation of materials

Processing

Use

Page 3: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Corrosion normally occurs due to defects or unexpected environments

Cruise missile fuel line

Page 4: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

A plastic encapsulated IC failed after 5 years in dormant storage.

Defects:

Damaged passivation

Au (galvanic couple)

0

500

1000

1500

2000

2500

3000

3500

4000

0 5000 10000 15000 20000Energy (eV)

Cou

nts

W

Au

W

AlAu

Page 5: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Several non-traditional corrosion mechanisms exist in microelectronics that involve electrical bias

Electrolytic dissolution

Cathodic corrosion (alkalization)

Electrolytic migration

Page 6: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Conditions required for electrolytic migration

Applied voltage • powered system

Susceptible alloy • Ag used in ground plane • Solder • Copper

Conductive surface • flux residue (activator)

Electrolyte • High humidity Temperature cycling

• Seacoast environment (NaCl)

Page 7: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Corrosive environments can contact metallization features

Breach in hermetic packaging in CHP Use of encapsulants in PEMs with

high water permeability

Specific unintended exposures (e.g., military) high T, RH, [Cl-] possible

Page 8: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Materials Degradation Affects Reliability

8

Probability of failure-free performance, item's useful life, or a specified timeframe specified environmental duty-cycle conditions.

Cost Reliability

Lab and Field Data Accelerated Tests

Accelerated testing plays a key role in determining reliability Must be applicable to failure

modes Reproduce field failures

Acceleration factor Range of stresses Long term tests

Page 9: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

The inverter is a significant contributor to reliability issues

9

Sun Edison – Owner/Operator (A. Golnas, “PV System Reliability: An Operator’s Perspective,” in 38th Photovoltaic Specialists Conference, Austin, TX, Jun. 2012, pp. 1–32.)

EVENTS

2003

2003

2003

2003 20

03

2003 2003

2003

2004

2004

2004

2004

2004

2004 20

04

2004

2005

2005

2005

2005

2005

2005

2005 2005

2006

2006

2006

2006

2006

2006 2006

2006

2007

2007

2007

2007

2007

2007 2007

2007

0

10

20

30

40

50

60

Inve

rter

Ligh

tnin

g

Row

Box

AC d

isco

nnec

t

PV M

odul

e

208V

/480

V Tr

ansf

orm

er

480V

/34.

5kV

Tran

sfor

mer

Mar

shal

ling

Box

Coded Category By Year

Num

ber o

f Eve

nts

20032004200520062007

Tucson Electric Springerville Plant. Sandia Study

Page 10: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

What? Component life tests High stresses

• Single or combined • Activate “appropriate” failure modes • Measureable

Time compression (cyclic stresses) Failure analysis Why? Time Full system is expensive and complicated

What is ALT & why?

Page 11: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Failure Modes for Crystalline Silicon (John Wolgemuth – BP Solar)

Broken interconnects Broken Cells Corrosion Delamination and/or loss of elastic properties Encapsulant discoloration Solder bond failures Broken glass Hot Spots Ground faults Junction box and module connection failures Structural failures

Would you expect a single test to capture all of the expected failure modes?

Page 12: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

It is important to understand the degradation mechanism and select appropriate stress level

12

Tem

pera

ture

Reaction Coordinate

25°C, 45 days

40°C, 30 days

100°C, 12 min

500°C, 5 min

Page 13: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

13

High T data are extrapolated to “use” conditions (room temperature)

Page 14: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

14

How you extrapolate can influence lifetime predictions.

~50% in ~ 1000 years

~50% in ~ 100 years

~50% in ~ 20 years

Page 15: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Two approaches to accelerated testing are used throughout industry

Qualitative Accelerated Tests • HALT tests • HAST tests • HASS tests

Quantitative Accelerated Life Tests

• Controlled application of accelerated stress

• Produces acceleration factors (AF) Usage rate acceleration

(Time compression) Overstress acceleration

Small sample size Severe level of stress

Increase reliability (product improvement) Qualify new designs Design quantitative ALT

Reliability under normal use conditions

Used to determine TTF Determine reliability

Long Time Need degradation / failure mechanisms

Page 16: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

The Goal of an ALT program is to produce acceleration factors

Often empirical correlations

Limited root-cause analyses

++

−=

obVabVa

n

oRHRH

T1

oT1

kaE

expAF

=

testMTTFMTTFAF field

Time-to-Fail40

1

510

25

50

75

9095

99

50 80 100Cu

mul

ativ

eFa

ilure

Perc

entil

e

MTTF

Page 17: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

ALT must capture valid degradation / failure mechanisms

17

10080604020

exp [B(T + RH)](RH) exp (E /kT)a

n

exp [E /kT + B(RH) ]a2

exp [E /kT + B/(RH)]a

exp [A/kT + B(RH)/kT + C(RH)]

RH (%)

AF

0

1

102

104

106

Calibration data collected here

Atmospheric Corrosion of Micrelectronics

Example:

• Five recognized models for corrosion in micro-electronics

• All agree at 85%RH

• Disagreement at 10%-30% prevent uniform application of either model

Page 18: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Acceleration factors depend on the stress characteristics

Thermal (Arrhenius) • Activation energy • Verify no mechanism change • Bin damage by time at temperature

∆T • Linear (time compressions), • Increased temperature range • Frequency analysis (rainflow counting)

Voltage • Linear (must understand relationship)

Humidity • Tends to be complex (adsorbed water)

8/1/2

011

7/26

/2011

7/21

/2011

7/16

/2011

7/11

/2011

7/6/2

011

80

70

60

50

40

30

20

10

Date and Time (MST)-July

Tem

pera

ture

(C)

Capacitor (°C)-JulyHeat Sink (°C)-JulyTorroid (°C)-JulyEnclosure (°C)-July

Variable

107550250-25

240

180

120

60

0

q

Torroid (°C)-Feb

Humidity

Rat

e

Page 19: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Issues with ALT

Unknown failure mechanisms Unknown / variable use environment Changing mechanisms as function

of environmental stress Difficult to control and

characterize defects Long duration experiments Evolving / improving technology

Page 20: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

What are the likely stresses that lead to Inverter Failure?

Voltage Temperature Thermal cycling Thermal Shock Vibration Mechanical Shock Humidity Contamination Mechanical Stress ??? ???

Heat

Light Moisture

Other

Page 21: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

How do we apply ALT to predicting end-of-life (wear out)?

Determine Failure Mechanisms (field exposures)

Understands stresses that activate the failure mechanisms

Devise ALT conditions that accelerate degradation / failure

Perform ALT (range of stressses)

Determine acceleration factors

Qualify Product

Improve Product Reliability

Validate New Designs

Estimate or Predict Reliabilty

Page 22: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Analysis of metal foil tape degradation

))(028.0(10 α+= tR

Generate ALT data

Develop “acceleration factors”

Module

Load RIE ×=

RIVIP ×=×= 2

Mean +2σ

-2σ

Determine performance effect

Apply acceleration factors to field

0

10

20

30

40

50

60

70

0 500 1000 1500 2000 2500

Resi

stan

ce (o

hm)

Time (Hrs)

Slide 13 Thermal Cycle

Circuit 1

Circuit 2

Circuit 3

Circuit 4

Circuit 5

Circuit 6

Circuit 7

020406080

100120140160180

0 3000 6000 9000 12000

Resis

tanc

e (o

hm)

Thermal Cycles

Ch 1

Ch 2

Ch 3

Ch 4

Ch 5

Ch 6

Page 23: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Use the ALT data to predict long-term performance degradation (wear-out???)

23

Page 24: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Summary

Accurate prediction of reliability is complex Requires understanding of degradation processes Data Driven

• Field data • Accelerated testing

Effect on performance (what is failure?) Includes uncertainty

Page 25: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Extra Slides

Page 26: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Example: Al bondpad corrosion: corrosion requires moisture and contamination & is accelerated by temperature.

26

0

500

1000

1500

2000

2500

3000

0 1000 2000 3000

Res

ista

nce

(m-o

hm)

Exposure Time (hrs)

1ug/cm2, 30C, 80% RHPEM 402

d1-w 1

d1-w 3

d1-w 4

d1-w 11

d1-w 12

d1-w 14

d1-w 15

d1-w 22

Three environmental variables (T, RH, [Cl])

No Failures!

Page 27: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Increasing contaminant level causes failure.

27

0

500

1000

1500

2000

2500

3000

0 50 100 150 200

Res

ista

nce

(m-o

hm)

Exposure Time (hrs)

20 ug/cm2, 30C, 80% RHPEM 414

d1-w 1

d1-w 3

d1-w 4

d1-w 11

d1-w 12

d1-w 14

d1-w 15

d1-w 22

0

500

1000

1500

2000

2500

3000

0 1 2 3

Res

ista

nce

(m-o

hm)

Exposure Time (hrs)

43 ug/cm3, 30C, 80% RHPEM 416

d1-w 1

d1-w 3

d1-w 4

d1-w 11

d1-w 12

d1-w 14

d1-w 15

d1-w 22

20X chloride

40X chloride

Distribution of failure times Not all failed Clear effect of [Cl]

Page 28: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Statistical treatment (life-data analysis) provides a means of analyzing the bondpad data

28

ReliaSoft Weibull++ 7 - www.ReliaSoft.comReliability vs Time Plot

β=0.2360, η=943.6290, ρ=0.8798

Time, (t)

Relia

bility

, R(t)

=1-F(

t)

0.000 1000.000200.000 400.000 600.000 800.0000.000

1.000

0.200

0.400

0.600

0.800

x 4

x 3

x 2

x 3

Reliability

Data 1Weibull-2PRRX SRM MED FMF=16/S=15

Data PointsReliability Line

Rob SorensenSandia National Labs5/28/201010:46:25 AM

10 ug/cm2, 30C, 30% RH

ReliaSoft Weibull++ 7 - www.ReliaSoft.comReliability vs Time Plot

β=0.7073, η=5.2052, ρ=0.9889

Time, (t)

Relia

bility

, R(t)

=1-F(

t)

0.000 90.00018.000 36.000 54.000 72.0000.000

1.000

0.200

0.400

0.600

0.800

x 2

Reliability

Data 1Weibull-2PRRX SRM MED FMF=14/S=0

Data PointsReliability Line

Rob SorensenSandia National Labs5/28/201010:50:59 AM

20 ug/cm2, 30C, 80% RH

ReliaSoft Weibull++ 7 - www.ReliaSoft.comReliability vs Time Plot

β=2.0355, η=0.6531, γ=0.3818, ρ=0.9576

Time, (t)

Relia

bility

, R(t)

=1-F(

t)

0.000 3.0000.600 1.200 1.800 2.4000.000

1.000

0.200

0.400

0.600

0.800

x 2

x 2

x 3

x 2

Reliability

Data 1Weibull-3PRRX SRM MED FMF=13/S=0

Data PointsReliability Line

Rob SorensenSandia National Labs5/28/201010:57:34 AM

40 ug/cm2, 30C, 80%RH

• Provides distributions • Includes suspension results • Basis for models {Pfail = f(T, RH, [Cl])}

=

testMTTFMTTFAF field

Page 29: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Bondpad corrosion is modeled as an additional series resistor

Voltage Comparator Circuit Prediction of the effect of corrosion on reliability

as f(storage location)

The distributed wirebond property (probability of failure) is input into an electrical system model & other component outcomes (reliability, performance threshold) can be determined

y p

0.97

0.975

0.98

0.985

0.99

0.995

1

0 20 40 60 80 100Time (years)

Desert

Gulf Coast

Arctic

Page 30: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Accelerated aging induced capacitor degradation.

30

500505510515520525530535540545550

0 500

Cap

acita

nce

(µF)

Time (hr)

C = 98% Co

561 661 761 861Time (hr)

Capacitance vs. Time

900V 80oC

C = 98% Co ~

~

Inverter Temperature Profile

8/1/20117/26/20117/21/20117/16/20117/11/20117/6/20117/1/2011

100

75

50

25

0

Date and Time

Tem

pera

ture

(C)

Ambient TemperatureTransformer CoreCapacitorInverter BackplateAmbient

Variable

Solectria Inverter - July

Pre failure signature

Capacitor failed in accelerated testing

Accelerated aging stresses included voltage and temperature

Accelerated Aging • Voltage & Temperature • Capacitor failure • Failure pre-cursor (decreased

capacitance)

Page 31: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Laboratory testing provides vital information for PV system reliability

Field Data (O&M, Failures, …)

Accelerated Testing / Lab Tests

System performance model must include wear out (end of life) information

Accelerated Aging of Tape Joint – Thermal

Cycling

ALT

Acceleration Factors

Lin k to Performance

Page 32: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Field failure data from very large plants indicate correlation between temperature and failure

32

Predictor Variables AC_Power Cabinet_Temp Coolant_Temp DC_AC DC_Current DC_Power DC_Voltage Inv_Amb

28 30 32 34 36 38 400.93

0.94

0.95

0.96

0.97

0.98

0.99

Cabinet Temp

AC

/DC

Failures concentrated here

50 52 54 56 58 60 62 64 66 680.6

0.65

0.7

0.75

0.8

0.85

0.9

0.95

1

Temperature (C)

CD

F

Surviving Units

Failed Units

Data from large plant

Cabinet Temp

<35.4 >35.4

1 Failed Inverter 222 Operational Inverters

AC/DC

<.95 >.95

10 Failed Inverters 55 Operational Inverters

0 Failed Inverters 20 Operational Inverters

N=308

N=85

Page 33: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Accelerated Aging for Inverter Development • No PV specific industry standard exists • HALT testing is spotty; independently applied • Separate needs identified for residential and commercial scale inverters • Failure modes identified but not in a uniform program applicable across the

industry • System predictive models will require inputs for inverters

Page 34: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Atmospheric Corrosion

Ceramic flat pack

Au/Al wirebond

Diode

Page 35: Corrosion and Accelerated Testing - NREL and Accelerated Testing Rob Sorensen 505-844-5558 . nrsoren@sandia.gov . Sandia National Laboratories Sandia is a multiprogram laboratory operated

Examples of electrolytic migration