99
1 Part - A : Building works 2 Part - B : Internal Sanitary & Water Supply Installation 3 Part - C : Site Development Works 4 Part - D(i): Fire Fighting works Part - D(ii) : Fire Detection & Alarm System 5 Part - E : Electrical Works including Lift 6 Part - F: HVAC works Total Rebate if any Grand Total Sl. No. Particulars COST ABSTRACT Name of Work: Construction of Research Park at IITG Campus. Amount (Rs.)

COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

1 Part - A : Building works

2 Part - B : Internal Sanitary & Water Supply Installation

3 Part - C : Site Development Works

4 Part - D(i): Fire Fighting works

Part - D(ii) : Fire Detection & Alarm System

5 Part - E : Electrical Works including Lift

6 Part - F: HVAC works

Total

Rebate if any

Grand Total

Sl. No. Particulars

COST ABSTRACT

Name of Work: Construction of Research Park at IITG Campus.

Amount (Rs.)

Page 2: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item no. Description Unit Quantity Rate in figure (Rs.) Rate in words Total Amount(Rs.)

1 BORED CAST IN SITU PILES

a

Boring, providing and installation bored cast-in-situ

reinforced cement concrete piles of grade M-30 of

specified diameter and length below the pile cap, to

carry a safe working load not less than specified,

excluding the cost of steel reinforcement but

including the cost of boring with bentonite solution

and temporary casing of appropriate length for

setting out and removal of same and the length of

the pile to be embedded in the pile cap etc. by

percussion drilling using Direct mud circulation

(DMC) or Bailer and chisel technique by tripod and

mechanical Winch Machine all complete, including

removal of excavated earth with all its lifts and

leads (length of pile for payment shall be measured

up to bottom of pile cap and all operations shall be

as per the requirements of IS:2911 part-I and good

engineering practice).

600 mm dia piles Rm 16100.00

b

Vertical load testing of piles in accordance with IS

2911 (Part IV) including installation of loading

platform by Kentledge/Anchor piles method and

preparation of pile head or construction of test cap

and dismantling of test cap after test etc. complete

as per specification & the direction of Engineer in-

charge.Note: 1. Initial and Routine Load Test shall not be

carried out by Dynamic method of testing.

Note: 2. Testing agency shall submitt the design of

loading platform for the approval of Engineer-in-

charge.

Initial load Test shall be done upto 2.5 times the

Safe Load capacity or up to the penetration of 10%

of the stem diameter.)

iInitial load test on Single pile above 50 tonne and

upto 100 tonne Safe capacity Per test 4

Bill of Quantity

Name of Work: Construction of Research Park at IITG Campus.

Part-A(Building works)

Page 3: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

ii

Initial load test on Single pile above 100 tonne and

upto 150 tonne capacity (As per Design required) Per test 4

iii

Routine load test on single piles above 50 tonne

and upto 100 tonne Safe capacity pile in

accordance with IS Code of practice IS: 2911 (part

IV) by Kentledge method including preparation of

pile head etc forSingle pilePer test 12.00

c

Integrity testing of Pile using Low Strain/ Sonic

Integrity Test/ Sonic Echo Test method in

accordance with IS 14893 including surface

preparation of pile top by removing soil, mud, dust

& chipping lean concrete lumps etc. and use of

computerised equipment and high skill trained

personal for conducting the test & submission of

results, all complete as per direction of Engineer-in-

charge. Per test 629.00

2 EARTH WORKS

a

Earth work in excavation by mechanical means

(Hydraulic excavator) / manual means in foundation

trenches or drains (not exceeding 1.5 m in width or

10 sqm on plan), including dressing of sides and

ramming of bottoms, including all lifts and leads

and getting out the excavated soil and disposal of

surplus excavated soil as directed, within the IITG

campus.All kinds of soil. Cum. 3695.00

b

Filling with available excavated earth (excluding

rock) in trenches, plinth, sides of foundations etc. in

layers not exceeding 20cm in depth, consolidating

each deposited layer by ramming and watering

including all lifts and leads. Cum 3374.00

c

Supplying and filling in plinth with imported granular

soil of approved quality sand under floors, including

watering, ramming, consolidating and dressing

complete. Cum 2416.00

3 ANTI TERMITE TREATMENT

Page 4: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Supplying and injecting chemical emulsion for pre-

constructional anti-termite treatment and creating a

chemical barrier under & all-round the column pits,

wall trenches, basement excavation, top surface of

plinth filling, junction of wall and floor, along the

external perimeter of building, expansion joints,

surroundings of pipes and conduits etc. complete.

Stages shall be treated as per CPWD specification.

(Plinth area of the building at ground floor level only

shall be measured for payments).- With

Chlorpyriphos Emulsifiable concentrate 20%

with 1% concentration./ or sqm 2757.00

4 CEMENT CONCRETE WORK

Providing and laying in position cement concrete

of specified grade excluding the cost of centering

and shuttering - All work up to plinth level :

a1:2:4 (1 cement : 2 coarse sand (zone-III) : 4

graded stone aggregate 20 mm nominal size). Cum 371.00

b1:3:6 (1 Cement : 3 coarse sand (zone-III): 6

graded stone aggregate 40 mm nominal size). Cum 437.00

c

Providing and laying damp-proof course 50mm

thick with cement concrete 1:2:4 (1 cement : 2

coarse sand(zone-III) : 4 graded stone aggregate

20mm nominal size) with approved water proofing

compound as per manufacturers' specifications. Sqm 114.00

d

Providing and laying of cement concrete of

proportion 1:5:10 (1cement : 5 sand : 10 AAC block

bats of size 40mm) in sunken floors at all floors,

heights and levels cum 105.00

e

Making plinth protection 50mm thick of cement

concrete 1:3:6 (1 cement : 3 coarse sand : 6

graded stone aggregate 20 mm nominal size) over

75mm thick bed of dry brick ballast 40 mm nominal

size, well rammed and consolidated and grouted

with fine sand, including necessary excavation,

levelling & dressing & finishing the top smooth.Sqm 198.00

5 CENTERING AND SHUTTERING WORK

Centering and shuttering including strutting,

propping etc. and removal of form for all heights :a Foundations, footings, bases for columns Sqm 591.00

Page 5: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

bWalls (any thickness) including attached pilasters,

butteresses, plinth and string courses etc. Sqm 8651.00

cSuspended floors, roofs, landings, balconies and

access platform. with water proof ply 12 mm thick Sqm 17774.00

dLintels, beams, plinth beams, girders, bressumers

and cantilevers. with water proof ply 12 mm thick Sqm 18100.00

eColumns, Pillars, Piers, Abutments, Posts and

Struts Sqm 9804.00

fStairs, (excluding landings) except spiral-staircases

Sqm 1214.00

g Extra for shuttering in circular work. Sqm 1390.00

h

Extra for additional height in centering, shuttering

where ever required with adequate bracing,

propping etc., including cost of de-shuttering and

decentering at all levels, over a height of 3.6 m, for

every additional height of 1 metre or part thereof

(Plan area to be measured).

iSuspended floors, roofs, landing, beams and

balconies (Plan area to be measured) Sqm 2179.00

6 STEEL REINFOCEMENT WORKS

Steel reinforcement for R.C.C. work including

straightening, cutting, bending, placing in position

and binding all complete upto plinth level & above

as per specifications and relevant IS Codes.

Thermo-Mechanically Treated bars of grade Fe-

500D Kg 2655621.00

7 RCC WORKS IN M-25 GRADE

Providing and laying in position machine batched

and machine mixed design mix M-25 grade

cement concrete for reinforced cement concrete

work, using cement content as per approved design

mix, including pumping of concrete to site of laying

but excluding the cost of centering, shuttering,

finishing and reinforcement, including admixtures in

recommended proportions as per IS: 9103 to

accelerate, retard setting of concrete, improve

workability without impairing strength and durability

as per direction of Engineer-in-charge.a All works upto plinth level Cum 253.00

b All works from plinth level upto floor V level Cum 120.00

Page 6: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

8 RCC WORKS IN M-30 GRADE

Providing and laying in position machine batched

and machine mixed design mix M-30 grade

cement concrete for reinforced cement concrete

work, using cement content as per approved design

mix, including pumping of concrete to site of laying

but excluding the cost of centering, shuttering,

finishing and reinforcement, including admixtures in

recommended proportions as per IS: 9103 to

accelerate, retard setting of concrete, improve

workability without impairing strength and durability

as per direction of Engineer-in-charge.a All works upto plinth level Cum 3189.00

b All works from plinth level upto floor V level Cum 4758.00

c

Including extra for R.C.C./ B.M.C/ R.M.C. work

above floor V level for each four floors or part

thereof.d All works above V level upto floor IX level Cum 3441.00

9 MASONRY WORKS

a

Brick work with common burnt clay F.P.S. (non

modular) bricks of class designation 7.5 in

foundation and plinth in Cement mortar 1:6 (1

cement : 6 coarse sand) Cum 410.00

b

Providing and laying autoclaved aerated cement

blocks masonry with 100 mm thick AAC blocks in

super structure above plinth level up to floor V level

in cement mortar 1:4 (1 cement : 4 coarse sand ).

The rate includes providing and placing in position

2 Nos 6 mm dia M.S. bars at every third course of

masonry work. Cum 37.00

c

Providing and laying autoclaved aerated cement

blocks masonry with 150mm/200mm/230 mm thick

AAC blocks in super structure above plinth level up

to floor V level with RCC band at sill level and lintel

level with approved block laying polymer modified

adhesive mortar all complete as per direction of

Engineerin- Charge. (The payment of RCC band

and reinforcement shall be made for seperately).Cum 1732.00

Page 7: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

d

Extra over item no-9(c) above for works above floor-

V level up to floor-IX level (Including extra for each

four floors or part thereof by mechanical means). Cum 700.00

e

Half brick masonry with common burnt clay F.P.S.

(non modular) bricks of class designation 7.5 in

superstructure above plinth level up to floor V level

Cement mortar 1:4 ( 1 cement :4 coarse sand) sqm 546.00

f

Extra over item 9e above for half brick masonry in

superstructure, above floor V level for every four

floors or part thereof . sqm 273.00

g

Extra for Providing and placing in position two

numbers 6mm dia. M.S. bars or equivalent hoop

iron at every third coarse of all half brick masonry

works at all floors, heights, levels. sqm 546.00

h

Making circular opening for exhaust fan upto 600

mm dia in AAC masonry work by providing proper

precast RCC ring of required diameter on edgeat all

floors, heights and levels. each 100.00

i

Honey-comb brick work 10/11.4 cm thick with

common burnt clay bricks of class designation 7.5

in super structure with cement mortar 1:4 (1

cement : 4 coarse sand)at all floors, heights, levels.

sqm 100.00

10 FLOORING

a

Providing flat brick soling under foundation, floor,

plinth beam including packing with coarse sand and

watering etc complete as directed with bricks class

designation-75 in cement mortar in proportion 1:4

including curing complete as specified and as

directed. sqm 500.00

Page 8: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

b

Providing and laying (double charged full body)

vitrified floor tiles of minimum 600mmx600mm

sizes (thickness as per manufacturer's

specifications) conforming to IS : 15622 of

approved make in all colours and shades, laid on

20mm thick cement mortar 1:4 (1 cement : 4 coarse

sand) including grouting the joints with EPOXY tile

jointing compounds of matching colours etc.,

complete at all floors, levels and

heights.(rooms,balcony,kitchen)

(i)in floors including use of specified sizes of spacers

sqm 3661.50

(ii) in Skirting and Risers of steps sqm 350.00

c

Providing and laying rectified Glazed Ceramic floor

tiles of size 400x400 mm or more (thickness to be

specified by the manufacturer), of 1st quality

conforming to IS : 15622, of approved make, in all

colours, shades, except White, Ivory, Grey, Fume

Red Brown, laid on 20 mm thick Cement Mortar 1:4

(1 Cement : 4 Coarse sand), in floors including

Filling the joints with EPOXY tiles jointing

compound of matching colours at toilets at all

floors. sqm 50.00

d

Providing and laying in floor heavy duty vitrified

antiskid matt finish tiles of minimum thickness 10

mm without warpage of approved design and

manufacturer laid on 20mm thick cement mortar

1:4 (1 cement:4 coarse sand) including filling the

joints with pigmented tile joint filler Nitotile-GR or

equivalent of matching shade and approved

manufacturer as per manufacturers specification

etc. and cleaning the surface with detergent and

water complete (size 300mm x 300mm) (Laundry

and Gym.) sqm 85.00

e

Providing and fixing 18mm thick mirror polish

granite slab of approved colour etc. over 20mm

cement mortar 1:3 (1 cement : 3 coarse sand) all

complete at all floors, heights, levels.

(i)

In Floors, landings,lift lobby,podium, kitchen slabs

etc of all sizes etc in approved patterns.(Area of

slab above 0.50sqm) sqm 1019.25

Page 9: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

(ii)In kitchen platform, wash basin counter,steps,

risers,skirting etc.(Area of slab up to 0.50sqm). sqm 20.00

(iii) In lift facade (Area of slab over 0.50sqm). sqm 30.00

(iv)

Extra for providing edge moulding to 18mm thick

marble stone counters,Vanities etc. including

machine polishing to edge to give high gloss finish

etc. complete as per design approved by Engineer-

in-Charge Granite work Metre 30.00

(v)

Extra for providing opening of required size &

shape for wash basins/kitchen sink in kitchen

platform, vanity counters and similar location in

marble/stone work including necessary holes for

pillar taps etc .including rubbing and polishing of cut

edges to bring to the original colour etc. complete.each 19.00

(vi)

Extra for fixing marble /granite stone over and

above corresponding basic item, in facia and drops

of width upto 150 mm with epoxy resin based

adhesive including cleaning etc. complete. m 19.00

f

Providing and laying CC pavement of mix M25 with

ready mixed concrete from batching plant. The

ready mixed concrete shall be laid and finished with

screed board vibrator, vacuum dewatering process

and finally finished by floating, brooming with wire

brush etc. complete as per specification and

directions of Engineer-incharge.(Parking area)cum 150.00

g

Providing and fixing markana Chak doongri marble

stone 18 mm thick, (average) over 20 mm thick

base mortar of proportion 1:4 (1 cement: 4 coarse

sand) laid and jointed with cement slurry including

rubbing and polishing complete in all respects

including cutting the stone to make noutch/ offset

on all corners vertical and horizontal and make as

per noutch details in drawing and directed (in

door/window sill) of required sizes in single piece.sqm 134.00

Page 10: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

h

Cement plaster skirting of all height with cement

mortar 1:3 ( 1 cement : 3 coarse sand) finished with

floating coat of neat cement including rounding of

junctions with floor where required. 18 mm thick

sqm 1050.00

i

52 mm thick cement concrete flooring with

concrete hardener topping, under layer 40 mm

thick cement concrete 1:2:4 (1 cement : 2 coarse

sand : 4 graded stone aggregate 20 mm nominal

size) and top layer 12 mm thick cement hardener

consisting of mix 1:2 (1 cement hardener mix : 2

graded stone aggregate 6 mm nominal size) by

volume, hardening compound mixed @ 2 litre per

50 kg of cement or as per manufacturer's

specifications. This includes cost of cement slurry,

but excluding the cost of nosing of steps etc.

complete.(Electrical room & AHU) Sqm 76.00

j

25 mm thick Kota stone slab flooring over 20

mm (average) thick base laid over and jointed with

grey cement slurry mixed with pigment to match the

shade of the slab, including rubbing and polishing

complete with base of cement mortar 1 : 4 (1

cement : 4 coarse sand) Sqm 315.00

k

8 mm thick Laminated wooden flooring of National

finish with classic look of AC4 grade, LWF-

CLASSICA 832 OAK BRIONE PLANK laid over 40

mm thick leveling layer of cement concrete 1:2:4 (1

cement : 2 coarse sand : 4 graded stone aggregate

10 mm nominal size) to be paid separately, levelled

smooth and finished complete with tongue &

groove joint, end and T profile wherever required

with adhesive bonding quality conforming to IS :

2046 Type S, including cost of adhesive of

approved quality. (Seminar rooms )Sqm 133.00

Page 11: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

l

8 mm thick Laminated wooden flooring of National

finish with classic look of AC4 grade, LWF-

CLASSICA 832 OAK BRIONE PLANK laid over 25

mm thick waterproof ply base over M. S. frame

work paid separately,levelled smooth and finished

complete with tongue & groove joint, end and T

profile wherever required with adhesive bonding

quality conforming to IS : 2046 Type S, including

cost of adhesive of approved quality.(Gymnasium)Sqm 40.00

m

12 mm thick Laminated wooden flooring of

National finish with classic look of AC4 grade, LWF-

CLASSICA 832 OAK BRIONE PLANK laid over 15

mm thick Cement Plaster 1:4 (1 cement : 4 coarse

sand ) to be paid separately, levelled smooth and

finished complete with tongue & groove joint, end

and T profile wherever required with adhesive

bonding quality conforming to IS : 2046 Type S,

including cost of adhesive of approved

quality.(Seminar rooms skirting) Rm 67.00

n

Providing and laying Antiskid Vitrified floor tiles

in sizes (600 x 600) mm (thickness to be specified

by the manufacturer) with water absorption less

than 0.08% and conforming to IS: 15622, of

approved make, in all colours and shades, laid on

20mm thick cement mortar 1:4 (1 cement : 4 coarse

sand), jointing with grey cement slurry @ 3.3kg/sqm

including grouting the joints with white cement and

matching pigments etc., complete.(Toilets)Sqm 103.00

Page 12: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

o

Providing and fixing PVC sheet flooring of thickness

of 2 mm with HOF-TORO SC/TARKETT the size of

2m x 20m . The product should be homogeneous

and single layered with PUR (Clean Sweep)range.

The wear surface shall consist of impregnated

polyurethane homogeneous mixture of PVC with

TRUESHIELD technology, Plasticizers without

DOP, Urethane, color pigments and filler

calendared to form a sheet. Color and pattern

details shall be dispersed throughout the thickness

of the wear layer. It should conform to group "T"

wear resistance as per EN 685, Flammability

resistance of class Bfl-s1 as per GB8624-2006,

Dynamic coefficient of friction of class DS as per

EN 13893, Thermal Resistance of 0.072m2K/W as

per EN 12667, Thermal conductivity of 0.071W/mK

as per EN12524, impact sound reduction of 3dB as

per ISO 10140, Slip Resistance of class R9 as per

DIN 51130, Residual indentation of 0.03mm as per

GB/T 4085-2005, Color fastness rating of ≥6 as per

ISO 105-B02, total weight being 3.3kg/m2 as per

EN430. The product shall be suitable for

applications in class 23/34/43 areas as per EN685.

Product shall exhibit antistatic behavior, resistance

to bacteria, resistance to chemical, resistance to

staining, suitability to castor chair. The product shall

be Floor Score certified with no SVHC content

published by European Chemicals Agency

(REACH). Product shall contribute to LEED points

under Indoor environmental quality category.

Equivalent to Armstrong Medintech Plus. Sqm 227.00

p

Extra for joining of PVC sheets by Hot Weelding

Chord. Rm 150.00

11 DADO

Providing and fixing 1st class degital ceramic tiles

of approved designs and makes of minimum

thickness 5.6 mm in dado in any pattern over 12

mm thick cement plaster 1:3 (1 cement : 3 coarse

sand) and jointed with tile jointing compound of

approved manufacturer complete as directed.a 300mm x 600mm in kitchen,toilets,OHT. sqm 750.00

Page 13: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

b

Kota stone slabs 20 mm thick in risers of steps,

skirting, dado and pillars laid on 12 mm (average)

thick cement mortar 1:3 (1 cement: 3 coarse sand)

and jointed with grey cement slurry mixed with

pigment to match the shade of the slabs, including

rubbing and polishing complete. Sqm 25.00

cExtra for pre finished nosing in treads of steps

of Kota stone/ sand stone slab. Rm 10.00

dExtra for Kota stone/ sand stone in treads of steps

and risers using single length up to 1.05 metre. Sqm 25.00

e

18 mm thick Cement plaster skirting up to 30 cm

height, with cement mortar 1:3 (1 cement : 3 coarse

sand), finished with a floating coat of neat cement.Sqm 379.00

f

Extra for making chequers of approved pattern on

cement concrete floors, steps, landing, pavements

etc. Sqm 105.00

12 DOORS AND WINDOWS

a

Providing and fixing pressed steel door frames

conforming to IS: 4351, manufactured from

commercial mild steel sheet of 1.60 mm thickness,

including hinges, jamb, lock jamb, bead and if

required angle threshold of mild steel angle of

section 50x25 mm, or base ties of 1.60 mm,

pressed mild steel welded or rigidly fixed together

by mechanical means, including M.S. pressed

butt hinges 2.5 mm thick with mortar guards, lock

strike plate and shock absorbers as specified and

applying a coat of approved steel primer after pre-

treatment of the surface as directed by Engineerin-

charge: [Profile E] Fixing with adjustable lugs with

split end tail to each jamb Rm 50.00

b

Providing and fixing of WPC (Wood Polyster

Composite)Door frame of size 125 x 65mm solid

with special wooden hot stamping/pigmented of

similar colour of door shutterduly attached with

Architrave of same colour of 64.2mm width and

12mm thickness on all the borders of the door

frame. The Door Frame should be, insect

,pest,water,acid proof and it should also be certified

by IGBC. Rm 595.00

Page 14: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

c

Providing and fixing of WPC ( Wood Polyster

Composite)Door Panel/shutter made of extruded

multicavity one piece having over all thickness of

30mm with side thickness portion of 15mm, with

high pressure laminate of desired colour duly

compressed with closing of bottom and upper side

and suitable reinforced at hinges side to hold

screws. The door panel should be insect

,pest,water,acid proof and it should also be certified

by IGBC. The product should be paintable and

polishable. 30 mm thick sqm 285.00

d

Providing and fixing Hollow metal fire rated doors

as per IS 3614 part-1 & part-2 for stability and

integrity. Pressed Galvanized steel confirming to IS

277 with the following specification. Recommended

fire door shall have doors tested at CBRI for

maximum rating of 2 hrs tested . Individual Test

certificates should also be available for glass used

in vision lites confirming the required fire ratings

/panels being a part of the fire door assembly.

Doors should be finished in Thermosetting Powder

Coating desired RAL Shades. Manufacturer test

certificate shall cover doors both single & double

leaf doors and Hardwares should pass European

certificate "CE" of conformity / UL with required fire

ratings. Any deviation in specification and sheet

thickness other than what is mentioned in the test

certificates are not allowed. Proper label confirming

the type of door and the hourly rating is mandatory.

Approved manufacturer Navair International Ltd or

equivalent subject to approval. And should be ISO

Certified company. The approved manufacturer are

Navair,AGNI suraksha, Godrej or equivalent .

Page 15: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Door frame shall be double rebate profile of

minimum size 154mm X 77 mm made out of

1.60mm (16gauge) minimum thick galvanized steel

sheet. NDRF 154x77 Frames shall be Butt jointed

and field assembled with self bolted. The frames

should be finished with Thermosetting Powder

Coating in desired RAL Shade. All provision should

be mortised, drilled and tapped for receiving

appropriate hardware. Frames should be provided

with back plate bracket and anchor fasteners for

installation on a finished plastered masonry wall

opening.

Door leaf shall be minimum 49mm thick fully flush

double skin door with or without vision lite. Door

leaf shall be manufactured from 1.20mm minimum

thick galvanised steel sheet. The internal

construction of the door should be rigid

reinforcement pads for receiving appropriate

hardware. The infill material shall be Rockwool

treated with Viper FRS 881 LH. All doors NSD

12049 shall be factory prepped for receiving

appropriate hardware and provided with necessary

reinforcement for hinges, locks, and door closers.

The edges should be interlocked with a bending

radius of 1.4mm. For pair of doors astragals has to

be provided on the meeting stile for both active and

inactive leaf. Vision lite shall be as per direction

of engineer in charge with a beeding and screws

from inside.The glass should be contraflam Door

Lite 11 mm of minimum size 350mm x 500mm clear

120 min fire rated and partially insulated (EW120),

Clear Toughened, interlatered glass having a

sound reduction of >37dB, LT of 86% and

compliant to class 2(B)2 category of Impact

Resistance as per EN 12600 standard from Saint

Gobain. ( Vision panel All doors and frames shall be finished with Powder

coating in desired Shades. Rate should include

supply and installation of door and hardware as per

application

Page 16: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

The rate includes the cost of all the materials, labor

& T & P required for proper completion of the item

decribed above. (For payment purpose the area of

opening including door frame shall only be

measured). The agency shall provide one number

additional door alongwith all frame and fittings for

getting it tested from CBRI Roorkee and in case

sample fails, additional sets after improvement shall

be provided for testing till the item passes in tests,

which shall not be included in measurements for

payment. (Main entry Door) sqm 94.00

e

Providing and fixing glazing in fire resistant door

shutters, fixed panels, ventilators and partitions

etc., with G.I. beading of appropriate size, made out

of 20 SWG G.I.sheet (zinc coating not less than

120 gm/m2), fire resistant sealant, including

applying a coat of approved fire resistant primer on

G.I. beading etc., complete all as per direction of

Engineer-incharge.With clear fire resistant glass panes 6mm thick of

approved brand, having minimum 60 minutes fire

resistance Sqm 71.00

e

Providing and fixing ISI marked flush door shutters

conforming to IS : 2202 (Part I) non-decorative

type, core of block board construction with frame of

1st class hard wood and well matched commercial

3 ply veneering with vertical grains or cross bands

and face veneers on both faces of shutters:

35 mm thick including ISI marked Stainless Steel

butt hinges with necessary screws. Sqm 112.00

f

Providing & Fixing decorative high pressure

laminated sheet of plain / wood grain in gloss /

matt/ suede finish with high density protective

surface layer and reverse side of adhesive bonding

quality conforming to IS : 2046 Type S, including

cost of adhesive of approved quality.

1.5 mm thick Sqm 225.50

Page 17: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

g

Providing and fixing Pre-laminated flat pressed 3

layer (medium density) particle board or graded

wood particle board IS : 3087 marked, with one

side decorative and other side balancing lamination

Grade I, Type II exterior grade IS : 12823 marked,

in shelves with screws and fittings wherever

required, edges to be painted with polyurethane

primer (fittings to be paid separately).

25 mm thick Sqm 127.00

h

Providing and fixing cup board shutters 25 mm

thick, with Pre-laminated flat pressed three layer

particle board or graded wood particle board IS:

12823 marked, exterior grade (Grade l Type ll),

having one side decorative lamination and other

side balancing lamination, including IInd class teak

wood lipping of 25 mm wide x12 mm thick with

necessary screws and bright finished stainless

steel piano hinges, complete as per direction of the

Engineer-in-Charge Sqm 130.00

i

Extra for providing lipping with 2nd class teak

wood battens 25 mm minimum depth on all edges

of flush door shutters (over all area of door shutter

to be measured). Sqm 208.00

j

Providing, fitting and fixing transparent P.V.C. sheet

of 1 mm thickness to be fixed to door shutter of

toilet as per drawings and directions of Engineer-

in–charge. (In toilet doors). sqm 216.00

k

Extra for providing vision panel of Rectangular

or square not exceeding 0.1 sqm in all type of flush

doors (cost of glass excluded) (overall area of door

shutter to be measured): Sqm 112.00

l

Providing and fixing bright /matt finished Stainless

Steel handles of approved quality & make with

necessary screws etc all complete with 125 mm.Each 232.00

m

Providing and fixing bright /matt finished Stainless

Steel handles of approved quality & make with

necessary screws etc all complete with 200 mm.Each 224.00

Page 18: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

n

Providing and fixing IS : 12817 marked stainless

steel butt hinges (heavy weight) with stainless

steel screws etc. complete :i 125x64x2.50 mm Each 344.00

ii 100x60x2.50 mm Each 168.00

iii 75x50x2.50 mm Each 204.00

o

Providing and fixing Stainless steel tower bolts

with necessary screw etc. complete.

(i)300x10 mm long(Make Model code 8577 of Godrej)

each 266.00

(ii)150x10 mm long(Make Model code 8576 of Godrej)

each 126.00

p

Providing and fixing special quality bright finished

brass cupboard or ward robe locks with four levers

of approved quality including necessary screws etc.

complete. 65mm Each 52.00

q

Providing and fixing bright finished brass hanging

type floor door stopper with necessary screws,

etc. complete. Each 196.00

r

Providing and fixing aluminium extruded section

body tubular type universal hydraulic door closer

(having brand logo embossed on the body, door

weight upto 80 kg to 120 kg with double speed

adjustment with necessary accessories and screws

etc. complete. Each 48.00

s

Providing and fixing chromium plated brass 100

mm mortice latch and lock with 6 levers and a

pair of lever handles of approved quality with

necessary screws etc. complete. Each 66.00

t

Providing and fixing chromium plated brass 50 mm

cupboard or wardrobe knobs with nuts complete.

Each 104.00

u

Supply of Pad locks ( Make: Model Ultra Sherlock

code 3293 of Godrej) each 70.00

v

Providing and fixing stainless steel sliding bolt with

nuts and screws etc. in entrance door shutters

including necessary arrangement for fixing in door

shutters with additional hook for providing lock in

open position of the door complete 250x16mm.

i 300x16mm (Make: Model code 8541 of Godrej) each 87.00

Page 19: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

ii 200x16mm (Make: Model code 8539 of Godrej) each 30.00

w

Providing and fixing magnetic catcher of approved

quality in cupboard / ward robe shutters, including

fixing with necessary screws etc. complete. Triple

strip vertical type Each 200.00

x

Providing and fixing PVC 32mm dia Door buffer in

doors including necessary screws etc

complete.(Make : Model code 8618 of Godrej) each 62.00

y

Providing and fixing stainless steel curtain rod

including finial,bracket,rings etc. complete.(make

Vista,MAC or equivalent) m 245.00

13

Structural steel work in single section, fixed with or

without connecting plate, including cutting, hoisting,

fixing in position and applying a priming coat of

approved steel primer all complete. Kg 1410.00

14

Supplying and fixing rolling shutters of approved

make, made of required size M.S. laths, interlocked

together through their entire length and jointed

together at the end by end locks, mounted on

specially designed pipe shaft with brackets, side

guides and arrangements for inside and

outside locking with push and pull operation

complete, including the cost of providing and fixing

necessary 27.5 cm long wire springs manufactured

from high tensile steel wire of adequate strength

conforming to IS: 4454 - part 1 and M.S. top cover

of required thickness for rolling shutters.

i

80x1.25 mm M.S. laths with 1.25 mm thick top

cover Sqm 18.00

ii

Providing and fixing ball bearing for rolling shutters.

Each 6.00

15

Extra for providing grilled rolling shutters

manufactured out of 8 mm dia M.S. bar instead of

laths as per design approved by Engineer-in-

charge, (area of grill to be measured). Sqm 4.00

Page 20: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

16

Providing and fixing circular/ Hexagonal cast iron

or M.S. sheet box for ceiling fan clamp, of

internal dia 140 mm, 73 mm height, top lid of 1.5

mm thick M.S. sheet with its top surface hacked for

proper bonding, top lid shall be screwed into the

cast iron/ M.S. sheet box by means of 3.3 mm dia

round headed screws, one lock at the corners.

Clamp shall be made of 12 mm dia M.S. bar bent to

shape as per standard drawing. Each 75.00

17

Steel work in built up tubular ( round, square or

rectangular hollow tubes etc.) trusses etc.,

including cutting, hoisting, fixing in position and

applying a priming coat of approved steel primer,

including welding and bolted with special shaped

washers etc. complete. Kg 7648.00

18Providing and fixing mild steel round holding down

bolts with nuts and washer plates complete. Kg 450.00

19

Steel work welded in built up sections/ framed work,

including cutting, hoisting, fixing in position and

applying a priming coat of approved steel primer

using structural steel etc. as required.

In gratings, frames, guard bar, ladder, railings,

brackets, gates, grill and similar works Kg 27721.00

20

Providing and fixing stainless steel ( Grade 304)

railing made of Hollow tubes, channels, plates etc.,

including welding, grinding, buffing, polishing and

making curvature (wherever required) and fitting

the same with necessary stainless steel nuts and

bolts complete, i/c fixing the railing with necessary

accessories & stainless steel dash fasteners ,

stainless steel bolts etc., of required size, on the top

of the floor or the side of waist slab with suitable

arrangement as per approval of Engineer-incharge, Kg 9151.00

21

Providing and fixing carbon steel galvanised (

minimum coating 5 micron) dash fastener of 10 mm

dia double threaded 6.8 grade (yield strength 480

N/mm2), counter sunk head, comprising of 10 m

dia polyamide PA 6 grade sleeve, including drilling

of hole in frame , concrete/ masonry, etc. as per

direction of Engineer-in-charge.

Page 21: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

a 10 x 60 mm Each 2400.00

b 10 x 140 mm Each 1196.00

22

Providing and fixing thermal insulation of ceiling

(under deck insulation) with Resin Bonded Fibre

glass wool conforming to IS : 8183, density 24kg /

m3, 50mm thick, wrapped in 200 G Virgin

Polythene bags, fixed to ceiling with metallic cleats

(50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm

x 24 gauge wire mesh, for top most ceiling of

building. Sqm 99.00

FINISHING

66

15 mm cement plaster on rough side of single or

half brick wall of mix 1:6 (1 cement: 6 coarse sand)

Sqm 12912.00

6720 mm cement plaster of mix 1:4 (1 cement: 4

coarse sand)

Note :- Rates for external plaster are for height upto

10m from ground level in less otherwise stated. Ie.

Upto 3rd floor Lv Sqm 5075.00

68

Including extra for plastering exterior walls of height

more than 10 m from ground level for every

additional height of 3.6m or part thereof.a 3rd. FLOOR Sqm 1353.21

b 4th. FLOOR Sqm 1293.65

c 5th. FLOOR Sqm 1293.65

d 6th. FLOOR Sqm 1293.65

e 7th. FLOOR Sqm 1293.65

f 8th. FLOOR Sqm 1231.21

g 9th. FLOOR Sqm 735.21

696 mm cement plaster of mix 1:3 (1 cement : 3 fine

sand) Sqm 6748.00

70

Providing and fixing 150mm wide 12 guage

25mmx25mm wire mesh over joints between RCC

columns, beams, lintels facias and brick wall with U

type MS nails and spread cement mortar 1:3 (1

cement : 3 coarse sand) to fix in position. m 5080.00

Page 22: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

71

Making of 12mmx25mm groove in exterior

plastered surface or RCC projection at all heights,

floors and levels. Grooves shall be made by fixing

of alluminum channels of required sizes in the

required paterns to the walls before plastering and

shall be removed after plastering. m 500.00

72

Providing and applying white cement based water

proof putty of approved brand and manufacturer,

over the exterior plastered wall surface to prepare

the surface even and smooth complete. Sqm 28296.00

73

Finishing walls with fungus and algae resistant

superior grade water proof acrylic paint of approved

brands and manufacturers and of required shades

after surface preparation to give an even shade to

all external surfaces of exterior walls (minimum two

or more coats) including application of one coat of

exterior primer at all heights, floors and levels.Sqm 13294.00

74 Neat cement punning. Sqm 272.00

75Extra for plastering on circular work not exceeding

6 m in radius:76 In one coat Sqm 317.00

77

Wall painting with acrylic emulsion paint of

approved brand and manufacture to give an even

shade with Two or more coats on new work Sqm 15349.00

78

Applying one coat of water thinnable cement primer

of approved brand and manufacture on wall

surface. Sqm 15349.00

79Finishing walls with textured exterior paint of

required shade

a

New work (Two or more coats applied @ 3.28 ltr/10

sqm) over and including priming coat of exterior

primer applied @ 2.20kg/10 sqm Sqm 647.00

b

Applying priming coat with ready mixed red oxide

zinc chromate primer of approved brand and

manufacture on steel galvanised iron/ steel works Sqm 111.00

c

Wall painting with acrylic emulsion paint of

approved brand and manufacture to give an even

shade with Two or more coats on new work Sqm 300.00

Page 23: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

d

Painting with synthetic enamel paint of approved

brand and manufacture to give an even shade with

Two or more coats on new work Sqm 155.00

e

Finishing walls with water proofing cement paint of

approved brand and manufacture and of required

shade to give an even shade -Three or more coats

sqm 661.00

f

Extra for plastering exterior walls of height more

than 10 m from ground level for every additional

height of 3 m or part thereof. sqm 24221.72

Roofing Work

80

Providing gola 75mmx75mm in cement concrete

1:2:4 ( 1 cement : 2 coarse sand : 4 stone

aggregate 10mm and down gauge) including

finishing with cement mortar 1:3 ( 1 cement : 3 fine

sand) as per standard design 75x75mm deep

chase. metre 400.00

81

Making Khurras 45cmx45cm with average min.

thickness of 5cm cement concrete 1:2:4 ( 1 cement

: 2 coarse sand : 4 graded stone aggregate of

20mm nominal size) over PVC sheet 1mx1mx400

micron, finished with 12mm cement plaster 1:3 ( 1

cement : 3 coarse sand ) and a coat of neat cement

rounding the edges and making and finishing the

outlet complete. each 50.00

82 WATER PROOFING

a

Providing water proofing treatment with best quality

acrylic polymer modified cementitious composite

slurry coating and fibre glass cloth of approved

brand over sunken floors & terraces as per

manufacturer’s specifications and as approved by

Engineer-in-charge. The waterproofing membrane

applied shall be subjected to water ponding test by

filling minimum 50 mm water for 2-3 days or as

specified by Engineer - In charge. Areas to be

observed from bottom and all wet spots & water

leakage area should be marked for treatment. If the

wet areas are observed, they should be treated by

reapplication of waterproofing membrane.(sunken

floor of toilet & kitchen, tiolet walls, )Sqm 1152.00

Page 24: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

b

Providing 12mm thick plaster to protect

waterproofing treatment in cement mortar 1:4 (

1cement : 4 coarse sand) . sqm 1152.00

c

Grading roof for water proofing treatment with;

Cement concrete 1:2:4 ( 1cement:2 coarse sand: 4

graded stone aggregate 20mm nominal size) cum 234.00

d

Providing and mixing water proofing material in

cement concrete/cement mortar in proportion as

recommended by the manufacturer. bag 1872.00

83 Water proofing Treatment at Roof surface.

a

Labour for cleaning of concrete surface to remove

dust, oil, grease including removal of existing loose

paint / coating, and cement laitance by cleaning

with compressed air, including all materials, labour,

tools and tackles complete Repairing surface

irregularities, damaged concrete in base slab, if

any, with a styrene butadiene polymer, Sika Latex

or equivalent modified repair mortar including a

coat of bonding agent of the same with cement

slurry including all material, labour, tools and

tackles complete Sqm 2614.00

b

Providing and applying 2 coats of Sikatop seal

109hi - 2 or approved equivalent, componant

polymer modified coating after application of

Sikatop seal 109hi primer over the roof after proper

surface preparation.A glass fibre cloth shall be put

in between two coats including labour tools and

tackles etc all complete. Sqm 2614.00

c

Supply and application of 1:3 cement-sand mortar,

mixed with Sika-Top 77 or approved equivalent the

polymer modified high quality emultion,as a coving

the corners of floors and the vertical surface in the

sunken area, and between floor and walls in the

remaining area. Sqm 2614.00

84 uPVC Windows

Page 25: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

a

Providing, supplying & fixing of Fixed Window

made out of multi chambered uPVC sections with

TPV gaskets having isolated drainage and

reinforced with Galvanized Iron of 120 GSM

profiles through out the window. The outer frame

having a overall size of 60 x 55 mm with

reinforcement of 1 mm thickness and Mullion with

overall size of 74 x 60 mm with reinforcement of

1mm thickness. Composition of profile shall

consists a minimum of 6 PHR of TiO₂ for every 100

parts of PVC resin.Window panels shall be

provided with 20mm DG Glass . Wall thickness of

frame & Mullion shall be 2.2 - 2.4 mm. Cost is

inclusive of all taxes, materials, labour, hire charges

of manchineries all lead and lifts etc.,complete as

per the directions of the Engineer-in charge of

work. Sqm 136.00

b

Providing, supplying & fixing of Openable Door

made out of multi chambered uPVC sections with

TPV gaskets having isolated drainage and

reinforced with Galvanized Iron of 120 GSM

profiles through out the window. The outer frame

having a overall size of 60 x 55 mm with

reinforcement of 1 mm thickness and sash with

overall size of 60 x 102 mm with reinforcement of 2

mm thickness. Glazing bead for fixing of glass shall

be of size 20 x 18mm and coextruded with gasket.

Composition of profile shall consists a minimum of

6 PHR of TiO₂ for every 100 parts of PVC resin.

Doors shall be provided with 20mm DG Glass ,

standard hardware & Multi point locking system of

Espag type adn 3D hinges. Wall thickness of frame

& sash shall be 2.2 - 2.4 mm. Cost is inclusive of all

taxes, materials, labour, hire charges of

manchineries all lead and lifts etc., complete as per

the directions of the Engineer-in charge of work.Sqm 60.80

Page 26: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

c

Providing, supplying & fixing of 2Track - 2Panel

Sliding Window With Bottom Fixed made out of

multi chambered uPVC sections with TPV gaskets

having isolated drainage and reinforced with

Galvanized Iron of 120 GSM profiles through out

the window. The top/bottom outer frame shall be

provided with 60 x 55 mm profile and reinforced

with 1.0 mm thickness. The outer frame having a

overall size of 60 x 45 mm with reinforcement of 1

mm thickness and sash with overall size of 39 x 58

mm with reinforcement of 1.5 mm thickness.

Glazing bead for fixing of glass shall be of size 20 x

18mm and coextruded with gasket. Composition of

profile shall consists a minimum of 6 PHR of TiO₂ for every 100 parts of PVC resin. Windows shall be

provided with 20mm DG glass, standard hardware

& Flush locking system. Wall thickness of frame &

sash shall be 2.2 - 2.4 mm.Cost is inclusive of all

taxes, materials, labour, hire charges of

manchineries all lead and lifts etc.,complete as per

the directions of the Engineer-in charge of work.Sqm 25.60

Page 27: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

d

Providing, supplying & fixing of 3 Track - 3 Panel

Sliding Window with Top Fixed made out of multi

chambered uPVC sections with TPV gaskets

having isolated drainage and reinforced with

Galvanized Iron of 120 GSM profiles through out

the window. The fixed window having a overall size

of 60 x 55 mm with reinforcement of 1 mm

thickness and sliding frame with outer frame of 108

x 45mm with sash of size 39 x 58mm with

reinforcement of 1.5mm .Glazing bead for fixing of

glass shall be of size 20 x 18mm and coextruded

with gasket. Composition of profile shall consists a

minimum of 6 PHR of TiO₂ for every 100 parts of

PVC resin. Windows shall be provided with 20mm

DG glass, standard hardware & Flush locking

system. Wall thickness of frame & sash shall be 2.2

- 2.4 mm.Cost is inclusive of all taxes, materials,

labour, hire charges of manchineries all lead and

lifts etc.,complete as per the directions of the

Engineer-in charge of work.Sqm 63.20

e

Providing, supplying & fixing of Fixed Window

made out of multi chambered uPVC sections with

TPV gaskets having isolated drainage and

reinforced with Galvanized Iron of 120 GSM

profiles through out the window. The outer frame

having a overall size of 60 x 55 mm with

reinforcement of 1 mm thickness and Mullion with

overall size of 74 x 60 mm with reinforcement of

1mm thickness. Composition of profile shall

consists a minimum of 6 PHR of TiO₂ for every 100

parts of PVC resin.Window panels shall be

provided with 20mm DG Glass . Wall thickness of

frame & Mullion shall be 2.2 - 2.4 mm. Cost is

inclusive of all taxes, materials, labour, hire charges

of manchineries all lead and lifts etc.,complete as

per the directions of the Engineer-in charge of

work. Sqm 100.80

Page 28: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

f

Providing, supplying & fixing of 2Track - 2Panel

Sliding Window made out of multi chambered

uPVC sections with TPV gaskets having isolated

drainage and reinforced with Galvanized Iron of

120 GSM profiles through out the window.The

outer frame having a overall size of 60 x 45 mm

with reinforcement of 1 mm thickness and sash with

overall size of 39 x 58 mm with reinforcement of 1.5

mm thickness. Glazing bead for fixing of glass shall

be of size 20 x 18mm and coextruded with gasket.

Composition of profile shall consists a minimum of

6 PHR of TiO₂ for every 100 parts of PVC resin.

Windows shall be provided with 20mm DG glass,

standard hardware & Flush locking system. Wall

thickness of frame & sash shall be 2.2 - 2.4

mm.Cost is inclusive of all taxes, materials, labour,

hire charges of manchineries all lead and lifts

etc.,complete as per the directions of the Engineer-

in charge of work. Sqm 141.00

g

Providing, supplying & fixing of 2Track - 2Panel

Sliding Window made out of multi chambered

uPVC sections with TPV gaskets having isolated

drainage and reinforced with Galvanized Iron of

120 GSM profiles through out the window.The

outer frame having a overall size of 60 x 45 mm

with reinforcement of 1 mm thickness and sash with

overall size of 39 x 58 mm with reinforcement of 1.5

mm thickness. Glazing bead for fixing of glass shall

be of size 20 x 18mm and coextruded with gasket.

Composition of profile shall consists a minimum of

6 PHR of TiO₂ for every 100 parts of PVC resin.

Windows shall be provided with 20mm DG glass,

standard hardware & Flush locking system. Wall

thickness of frame & sash shall be 2.2 - 2.4

mm.Cost is inclusive of all taxes, materials, labour,

hire charges of manchineries all lead and lifts

etc.,complete as per the directions of the Engineer-

in charge of work. Sqm 122.00

Page 29: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

h

Providing, supplying & fixing of 2Track - 2Panel

Sliding Window made out of multi chambered

uPVC sections with TPV gaskets having isolated

drainage and reinforced with Galvanized Iron of

120 GSM profiles through out the window.The

outer frame having a overall size of 60 x 45 mm

with reinforcement of 1 mm thickness and sash with

overall size of 39 x 58 mm with reinforcement of 1.5

mm thickness. Glazing bead for fixing of glass shall

be of size 20 x 18mm and coextruded with gasket.

Composition of profile shall consists a minimum of

6 PHR of TiO₂ for every 100 parts of PVC resin.

Windows shall be provided with 20mm DG glass,

standard hardware & Flush locking system. Wall

thickness of frame & sash shall be 2.2 - 2.4

mm.Cost is inclusive of all taxes, materials, labour,

hire charges of manchineries all lead and lifts

etc.,complete as per the directions of the Engineer-

in charge of work. Sqm 26.00

i

Providing, supplying & fixing of 2Track - 2Panel

Sliding Window With Top & Bottom Fixed made

out of multi chambered uPVC sections with TPV

gaskets having isolated drainage and reinforced

with Galvanized Iron of 120 GSM profiles through

out the window. The top/bottom outer frame shall

be provided with 60 x 55 mm profile and reinforced

with 1.0 mm thickness. The outer frame having a

overall size of 60 x 45 mm with reinforcement of 1

mm thickness and sash with overall size of 39 x 58

mm with reinforcement of 1.5 mm thickness.

Glazing bead for fixing of glass shall be of size 20 x

18mm and coextruded with gasket. Composition of

profile shall consists a minimum of 6 PHR of TiO₂ for every 100 parts of PVC resin. Windows shall be

provided with 20mm DG glass, standard hardware

& Flush locking system. Wall thickness of frame &

sash shall be 2 - 2.2 mm.Cost is inclusive of all

taxes, materials, labour, hire charges of

manchineries all lead and lifts etc.,complete as per

the directions of the Engineer-in charge of work.Sqm 208.80

Page 30: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

j

Providing, supplying & fixing of Top Hung Window

made out of multi chambered uPVC sections with

TPV gaskets having isolated drainage and

reinforced with Galvanized Iron of 120 GSM

profiles through out the window. The outer frame

having a overall size of 60 x 55 mm with

reinforcement of 1 mm thickness and sash with

overall size of 60 x 75 mm with reinforcement of 1.5

mm thickness. Glazing bead for fixing of glass shall

be of size 20 x 18mm and coextruded with gasket.

Composition of profile shall consists a minimum of

6 PHR of TiO₂ for every 100 parts of PVC resin.

They shall be provided with 5mm Clear glass,

standard hardware & Multi point locking system of

Espag type/ Wall thickness of frame & sash shall

be 2 - 2.2 mm.Cost is inclusive of all taxes,

materials, labour, hire charges of manchineries all

lead and lifts etc.,complete as per the directions of

the Engineer-in charge of work.Sqm 42.40

k

Providing, supplying & fixing of Top Hung Window

made out of multi chambered uPVC sections with

TPV gaskets having isolated drainage and

reinforced with Galvanized Iron of 120 GSM

profiles through out the window. The outer frame

having a overall size of 60 x 55 mm with

reinforcement of 1 mm thickness and sash with

overall size of 60 x 75 mm with reinforcement of 1.5

mm thickness. Glazing bead for fixing of glass shall

be of size 20 x 18mm and coextruded with gasket.

Composition of profile shall consists a minimum of

6 PHR of TiO₂ for every 100 parts of PVC resin.

They shall be provided with 5mm Clear glass,

standard hardware & Multi point locking system of

Espag type/ Wall thickness of frame & sash shall

be 2 - 2.2 mm.Cost is inclusive of all taxes,

materials, labour, hire charges of manchineries all

lead and lifts etc.,complete as per the directions of

the Engineer-in charge of work.Sqm 8.00

MISCELLANEOUS ITEMS

Page 31: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

85

Providing and fixing 40mm dia G.I. pipe for spout

including cutting holes in walls and making good

the same.

600mm long each 80.00

86

Providing and fixing false ceiling tiles of

Dexune/Armstrong/Nittobo make of size 595x595

mm in true horizontal level suspended in inter

locking metal grid of hot dipped galvanised steel

sections (galvanised @170gsm/sqm) consisting of

main "T" runner suitably spaced at joints to get

required length and size of 15x32mm made from

0.30 mm thk (minimum) sheet spaced at 1200 mm

c/c and cross tee of size 15x27mm made of 0.3mm

thk (minimum) sheet, 1200 mm long spaced

between main Tat 600 mm c/c to form a grid of

1200x600mm and secondary cross T of length

600mm and size 15x27 mm made of 0.30 mm thk

(minimum) sheet to be interlocked at middle of the

1200x600 mm panel to form grids of 600x600mm

and laying false ceiling tiles of approved texture in

the grid including, wherever, required,

cutting/making,opeings for services like

diffusers,grills,light fittings, fixtures, smoke

detectors etc. Main T runners to be suspended

from ceiling using GI slotted cleats fixed to the

ceiling with 6mm dia and 50mm long dash

fastners,4mm GI adjustable rods with galvanised

level clips spaced at 1200 mmc/c along main T , bottom exposed width of 15 mm

of all the T sections shall be prepainted with

polyester paint, all complete t all heights as per

specifications drawings & as directed by engineer

incharge. the rate is including cost of mineral fibre

600mmx600mm Armstrong/Dexune/Nittobo ceiling

tiles dune 15mm thk micro look white colour sqm 2610.00

Page 32: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

87

Supply and fixing of approved brand 150F Plain

Aluminum Panel Facade Cladding of approved

manufacturer manufactured of approved colour

consisting of panels150mm wide x17mm deep x

0.7mm thick panel length up to 6 mtrs, Coil Coated

on a Continuous Paint Line, Double-baked and roll

farmed from enameled Corrosion Resistance

Aluminium Alloy AA3005 (Al.Mn) for higher

Strength and good Roll Forming characteristics.

Panel shall be clipped to Baked enamel!ed

Aluminium Panel Carrier of 34.5 mm wide x 48mm

deep x0.95mm thick in Standard lengths of 5metrs

made of double baked enameled Aluminum Alloy

AA'5050(Al..Mg).The panel Carrier Shall be

mounted by Means of suitableSub-Structure (shall

be charged as extra as separate item).

Paint Finish: Aluminium panels :shall be

chromatised for Maximum bond between metal and

paint enameled twice under high temperature one

side with full primer and Luxacote finish the other

side (innerside)with a primer coat and skin coat on

a Continuous Paint Line Sqm 457.60

88

Drilling with core cutting machine in RCC

beams,slabs,floorsetc.,for laying pipes and

rendering the same in RCC 1:2:4 finishing the

same to the satisifaction of the owner or his

authorised representative etc.,including nominal

reinforcement wherever required,complete,at all

levels The quote shall also include for providing

EPOXY based water proofing compound for sealing

the joints around the pipes upto 250mm max depth

at all heights & levels

aAbove 75mm dia and upto 100mm dia. (depth of

hole 100 mm to 200 mm) Nos 37.00

bAbove 101mm dia. and up to 200mm dia (depth of

hole 100 mm to 200 mm) Nos 66.00

ALUMINIUM WORKS

Page 33: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

89

Providing and fixing aluminium work for doors,

windows, ventilators and partitions with extruded

built up standard tubular sections/ appropriate Z

sections and other sections of approved make

conforming to IS: 733 and IS: 1285, fixing with dash

fasteners of required dia and size, including

necessary filling up the gaps at junctions, i.e. at top,

bottom and sides with required EPDM rubber/

neoprene gasket etc. Aluminium sections shall be

smooth, rust free, straight, mitred and jointed

mechanically wherever required including cleat

angle, Aluminium snap beading for glazing /

paneling, C.P. brass / stainless steel screws, all

complete as per architectural drawings and the

directions of Engineer-in-charge. (Glazing, paneling

and dash fasteners to be paid for separately) :

a For fixed portion

Polyester powder coated aluminium

(minimum thickness of polyester powder

coating 50 micron) Kg 404.00

b

For shutters of doors, windows & ventilators

including providing and fixing hinges/ pivots and

making provision for fixing of fittings wherever

required including the cost of EPDM rubber /

neoprene gasket required (Fittings shall be paid for

separately)

Polyester powder coated aluminium

(minimum thickness of polyester powder

coating 50 micron) Kg 880.00

c

Providing and fixing glazing in aluminium door,

window, ventilator shutters and partitions etc. with

PVC/ neoprene gasket etc. complete as per the

Architectural drawings and the direction of Engineer

- in - Charge (Coast of aluminium snap beading

shall be paid in basic item) :(i) With frosted glass panes of 4.0 mm thickness sqm 43.00

(ii) With float glass panes of 5.0 mm thickness sqm 162.00

(iii) Extra for providing toughening of glass sqm 162.00

Page 34: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

d

Filling the gap in between aluminium frame &

adjacent RCC/ Brick/ Stone work by providing

weather silicon sealant over backer rod of

approved quality as per architectural drawings and

direction of Engineer-in-charge complete.

Upto 5mm depth and 5 mm width Rm 1713.00

e

Providing and fixing 12 mm thick prelaminated

particle board flat pressed three layer or graded

wood particle board conforming to IS: 12823 Grade

l Type ll, in panelling fixed in aluminum doors,

windows shutters and partition frames with C.P.

brass / stainless steel screws etc. complete as per

architectural drawings and directions of Engineer-in-

charge.

f

Pre-laminated particle board with decorative

lamination on both sides Sqm 114.00

90

Providing & fixing double action hydraulic floor

spring of approved brand and manufacturer

(conforming IS:6315) for aluminium doors including

cost of cutting floors as required, embedding in

floors and cover plates etc. as per direction of

Engineer-in-Charge.(With stainless steel cover

plate minimum 1.25 mm thickness of D60 Floor

spring (60 kg) LKYGDF0FS 7477 Godrej Make)

With SS cover plate minimum 1.25 mm thickness Each 128.00

91 EXPANSION JOINT

a

Expansion Joints Treatment with Sikadur Combiflex

System

Step-1. Removal of extra topping between the

expansion joint area: Preparation of Expansion

Joint edge by grinding and removal of all loose

particles, dirt, dust etc to make the surface clean

including scaffolding , tools tackles etc all complete

Step-2. Providing and Mixing of epoxy adhesive

sikadur 31 C (2:1) by mechanical mixture and apply

on the 50 mm surface of both sides as per the

manufacturer specification including tools, labour,

machines etc all complete

Page 35: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Step-3. Providing and Fixing of Hypalon based

Sikadur Combiflex SG strip (200 mm width x 2mm

thickness on the expansion joint as per the

manufacturer specification including tools, labour,

machines scaffoldings etc all complete

Step-4. Finally Providing and Mixing of epoxy

adhesive sikadur 31 C (2:1) by mechanical mixture

and apply on the 50 mm surface of both sides as

per the manufacturer specification including tools,

labour, machines etc all complete as a protective

coating Rm 450.00

b

Preparing the surface by cleaning and chipping the

surface for removing loose, laitance etc. All the

construction joints should be cut in a groove and

wash the entire surface thoroughly by water making

the surface saturated dry condition and filling the

gaps with polymer modified mortar with Asian MPP.

Applying polysulphide Sealant primer on both the

edges. Finally application of polysulphide Sealant in

the gap of 6 mmx 40 mm depth. Rm 450.00

c

Providing and fixing machine moulded aluminium

covering of approved pattern & design, made out of

machine cut aluminium sheet and machine holed

for receiving dash fastener, over expansion joints

on vertical surfaces/ceiling floors, the fixing on plate

in one row on one side of joint only shall be done

with stainless steel dash fasteners of 8 mm dia and

75 mm long bolt including providing aluminium

washers 2 mm thick & 15 mm dia , at a staggered

pitch of 200mm centre to centre including drilling

holes in the receiving surface and providing

expandable plastic sleeves in holes etc. complete

as per direction of Engineer-in-charge.

Powder coated aluminium sheet 2.5mm thick

(minimum thickness of powder coating 50 micron), [

7.00 kg/ sqm ] Kg 496.00

STRUCTURAL GLAZING

Page 36: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

92

Providing and supplying aluminium extruded tubular

and other aluminium sections as per the

architectural drawings and approved shop drawings

, the aluminium quality as per grade 6063 T5 or T6

as per BS 1474,including super durable powder

coating of 60-80 microns conforming to AAMA 2604

of required colour and shade as approved by the

Engineer-in-Charge. (The item includes cost of

material such as cleats, sleeves, screws etc.

necessary for fabrication of extruded aluminium

frame work. Nothing extra shall

be paid on this account).Kg 617.00

93

Providing, assembling and supplying vision glass

panels (IGUs) comprising of hermetically-sealed 6-

12- 6 mm insulated glass (double glazed) vision

panel units of size and shape as required and

specified, comprising of an outer heat strengthened

float glass 6mm thick, of approved colour and

shade with reflective soft coating on surface # 2 of

approved colour and shade, an inner Heat

strengthned clear float glass 6mm thick, spacer

tube 12mm wide, dessicants, including primary seal

and secondary seal (structural silicone sealant) etc.

all complete for the required performances, as per

the Architectural drawings, as per the approved

shop drawings, as specified and as directed by the

Engineer-in-Charge. The IGUs shall be assembled

in the factory/ workshop of the glass

processor.“(Payment for fixing of IGU Panels in the

curtain glazing is included in cost of item

No.26.2)“For payment, only the actual area of glass

on face # 1 of the glass panels (excluding the areas

of the grooves and weather silicone sealant)

provided and fixed in position, shall be measuredin

sqm.“

Page 37: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

a

Coloured tinted float glass 6mm thick substrate

with reflective soft coating on face # 2, + 12mm

Airgap + 6mm Heat Strengthened clear Glass of

approved make having properties as visible Light

transmittance (VLT) of 25 to 35 %, Light reflection

internal 10 to 15%, light reflection external 10 to 20

%, shading coefficient (0.25- 0.28) and U value of

3.0 to 3.3 W/m2 degree K etc. The properties of

performance glass shall be decided by technical

sanctioning authority as per the site requirement.Sqm 190.00

b

Extra for openable side / top hung vision glass

panels (IGUs) including providing and supplying at

site all accessories and hardwares for the openable

panels as specified and of the approved make such

as heavy duty stainless steel friction hinges, min 4 -

point cremone locking sets with stainless steel

plates, handles, buffers etc. including necessary

stainless steel screws/ fasteners, nuts, bolts,

washers etc. all complete as per the Architectural

drawings, as per the approved shop drawings, as

specified and as directed by the Engineer- in-

Charge. Sqm 61.00

Total of Part-A

Page 38: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item

no.

Description Unit Quantity Rate in figure (Rs.) Rate in words Total Amount(Rs.)

1Providing and fixing white vitreous china three pieces

water closet (European type W.C. pan) with dual flush

fitting, of flushing capacity 2 litre/ 4 litre including flush

pipe,cistern with lid, conforming to IS : 7231, with all

fittings and fixtures complete, including cutting and

making good the walls and floors wherever required(

Make Model No.Hindware cornice wall mounted

92055, cist : 92121 of Hindware or equivalent)

Each 69.00

2Providing and fixing water closet squatting pan (Indian

type W.C. pan ) with 100 mm sand cast Iron P or S

trap, 10 litre low level white P.V.C. flushing cistern,

including flush pipe, with manually controlled device

(handle lever) conforming to IS : 7231, with all fittings

and fixtures complete, including cutting and making

good the walls and floors wherever required:

(a) White Vitreous china Orissa pattern W.C. pan of

size 580x440 mm with integral type foot restsEach 2.00

3

Providing and fixing white vitreous china oval wash

basin of size 560 x 450 mm, for under counter

mounting, specially fabricated brackets,C.P.brass 32

mm CP brass waste coupling including cutting and

making good the walls, wherever required.( Make

Hindware Cat No. 10049, C.P.brass 32 mm CP, brass

waste coupling ,Model No. 709 / 705 , jaquar or

equivalent )

each 74.00

4

Providing and fixing glazed vitreous china flat back

urinals approx. size 375X315X620 mm with

infrared /ultra violet electric operated concealed

auto flush sensor 15mm dia. complete including

making connection with CP brass pipe to CP

spreaders, 32mm domical waste with 32mm

brass bottle trap and pipe to wall, wall flanges

comp. including cutting and making good the

walls and floors complete wherever required.

(Make: Model URS-WHT-132530 of Jaquar or

equivalent )

each 35.00

Bill of Quantity

Name of Work: Construction of Research Park at IITG Campus.

Part-B(Sanitary and water supply works)

Page 39: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

5

Providing and fixing CP brass urinal valve auto

closing system with built in control cock & wall

flange of approved quality with wall flanges

complete.-15mmNB,98mm long weighing not less

than 75gm.

each 35.00

6

Providing and fixing urinal partition with frosted

safety glass of 8mm thick of size 900mm(height)

x 450 mm(width) corner chamfered fixed in brick

wall with stainless steel clips of grade 304 all

complete.(Model 1810-US or 1810-UC of Jaquar

or equivalant)

sqm 31.00

7

Providing & fixing 32 mm dia CP brass bottle trap

including fisher union for wash basins complete Cal no

ALD 769 of Jaquar or equivalent)each 109.00

8

Providing & fixing 1mm thick Stainless steel kitchen

sink of grade-304 as per IS: 13983 with 32 mm C.P.

brass waste coupling complete including the fittings,

cutting and making good the wall wherever required,

1000 x 500 x 178 bowl size with drain board.(Make:

Nirali Elegance unique or equivalent)

No. 24.00

9

Providing and fixing PVC waste pipe of standard

pattern for wash basins, sinks etc. of approved make.

(a) 40 mm dia each 24.00

10

Supply and fixing 15mm CP brass Sink Cock with

swinging casted spout wall flange and suitable length

CP brass extension pipe all of approved make (CP

fittings CAT No. FLR5347ND of Jaquar or equvalent).

each 24.00

11

Providing and fixing 600x120x5mm glass shelf with

edges rounded off fixed with necessary screws, raw

plugs etc. all complete. (Make: Model ACN1171N of

Jaquar continental)

each 74.00

12

Providing and fixing 600x450 mm beveled edge mirror

of superior glass (of approved quality) complete with 6

mm thick hard board ground fixed to wooden cleats

with C.P. brass screws and washers complete.

each 74.00

13

Providing and fixing of 600mm long towel rail Jaquar

Cat No. AKP-35711P or equivalent make all complete

with required acceessories as directed by the Engineer-

in-Charge.

each 24.00

Page 40: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

14

Providing & fixing CP towel ring of size 150mm dia of

approved make ( Make : Model AKP35721P of

Jaquaer Queen's)each 48.00

15

Providing & fixing stainless steel soap tray of approved

make and design with necessary screws for wash

basin (Make : Model AKP-35731P of Jaquar)

each 122.00

16

Providing and fixing CP brass toilet paper holder as

directed by Engineer in Charge (Make: Model-

AKP35753P of Jaquar or Equivalent).Each 69.00

17

Providing & fixing stainless steel Shower basket of

approved make and design with necessary screws for

toilets (Make : Model ACN 1177N of Jaquar OR

equivalent)

each 24.00

18

Providing and fixing C.P. brass wall mixer 3-in-1

system with provision for both hand shower and

overhead shower complete with 115mm long bend

pipe , connecting legs & wall flange ( without hand and

overhead shower) etc complete.( Jquar Cat No

FLR5281N or equivalent)

each 24.00

19

Providing and fixing C.P bib cock with wall flange

including cutting and making good the walls wherever

required all complete as directed by the Engineer-in-

Charge.Charge.

(a) 2- way bib cock Jaquar Cat No.FLR-5041N or

equivalenteach 76.00

(b) Standard Bib cock (Make Model FLR 5047N of

Jaquar or equivalent)each 48.00

20

Providing and fixing C.P. angular stop cock of 15mm

nominal bore complete with flange and C.P. copper

connection (Make Model FLR 5053 N of Jaquar

Florentine)

each 199.00

21

Providing and fixing C.P. brass overhead shower 100

mm round shape multi flow (ABS Body chrome plated

with gray face plate ) with rubit cleaning system with

wall flange etc ( Jquar Cat No OHS-1999 or

equivalent)

each 24.00

22

Providing and fixing C.P. brass pillar cock of approved

quality conforming to I.S. standards - 15mm nominal

bore.(Make Model FLR 5015 N of Jaquar or

equivalent)

each 74.00

Page 41: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

23

Providing and fixing C.P. brass close hole basin mixer

pillar tap of approved quality and make, weighting not

less 1-970kg - 15mm nominal bore of standard back

type .(Make Model FLR 5001B of Jaquar Florentine).

each 24.00

24

Providing and fixing health faucet with 8mm dia,1m

long flexible tube & wall hook with NRV (back flow

preventer) of approved quality and make,(Make Model

ALD 577 of Jaquar or equivalent).

each 76.00

25

Supply and fixing 450 mm long braided connection

pipe with two15mm nuts & rubber washers etc. of

approved make ( CAT No.ALD 803AB of Jaquar or

Equivalent )

each 145.00

26

Providing, fitting and fixing of foldable horizontal Grab

Bar of stainless ateel (Make Jaquar or equivalent) for

person with disabilities (for WC)Each 4.00

27

Providing, fitting and fixing of vertical Grab Bar long

satin 692 mm of Jaquar or Equivalent for person with

disabilities. (for wash basin & WC)Each 12.00

28

Providing and fixing Hot water GEYSER of approved

Make- Havells including with two nos connection pipe

450 mm long.

(a) 10 Ltrs capacity Each 24.00

29

Providing, fixing, testing & commissioning of Bathroom

Drain (Make-Viega model no.-4935.1) Article Code-

557119 with Sealing flange,with removable

trap,(Storage Water Height 50 mm-Water

Seal),without top,with protection plug, with rotable

supply DN40, with horizontal drain socket,with outlet

100 mm. Drain capacity 1.7-1.1L/s WITH height

adjustable and rotratable TOP FRAME Model-4922.4

Article Code-534523(Height adjustment piece) 150x

150 (suitable for 143x143 GRATE) WITH BACK

PRESSURE SEAL.WITH STAINLESS STEEL

GRATE(143x143)Model- 4933.4 Article Code-

554040. LOADING CAPACITY CLASS K=300KG

Quality controlled in accordance with DIN EN -

1253(Body and Top Frame made of environmentall

friendly PP (poly propylene)

each 24.00

Page 42: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

30

Providing & fixing in position uPVC P"or S" trap/elbow

of self cleaning design of following sizes for the

embedded areas. Making proper connection with drip-

seal joints, cutting chase / hole in floors /slabs and

bringing the same in proper condition in cement

concrete 1:2:4 mix complete as required. including

cost of cutting and making good the walls and floors

where required.

(a) 110 mm inlet and 110 mm outlet each 210.00

(b) 110 mm inlet and 63 mm outlet (Floor Drains only)each 40.00

31

Providing and fixing 100 mm dia S.S grating (with or

without hole) for floor or Nahani trap.each 250.00

32

Providing and fixing on wall face un-plasticised - Rigid

PVC sewer pipes conforming to IS:13592 Type-B

including jointing with seal ring conforming to IS:5382

leaving 10mm gap for thermal expansion single

socketed pipes with all accessories as bend, door

bend, horn bend etc., complete as directed.

(a) 110 mm nominal bore m 750.00(b) 150 mm nominal bore m 692.00

33

Providing & fixing in position un-plasticised-Rigid PVC

waste pipes with necessary fittings, cutting & chasing

walls/floors etc. and making good the same.

(a) 40 mm dia metre 75.00

34

Providing, fitting and fixing of three layered white

outside ,black middle and blue inside PVC storage

water tank of approved make as per IS:12701 of all

capacity with cover and locking arrangement complete

as directed.

per litre

capacity15000.00

35

Providing and fixing Chlorinated Polyvinyl Chloride

(CPVC) pipes, having thermal stability for hot & cold

water supply, including all CPVC plain & brass

threaded fittings, i/c fixing the pipe with clamps at 1.00

m spacing. This includes jointing of pipes & fittings with

one step CPVC solvent cement and the cost of cutting

chases and making good the same including testing of

joints complete as per direction of Engineer in Charge.

Concealed work, including cutting chases and making

good the walls etc.

(a) 15 mm nominal outer dia Pipes m 150.00(b) 20 mm nominal outer dia Pipes m 650.00

Page 43: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

36

Providing and fixing Chlorinated Polyvinyl Chloride

(CPVC) pipes, having thermal stability for hot & cold

water supply including all CPVC plain & brass threaded

fittings This includes jointing of pipes & fittings with one

step CPVC solvent cement, trenching, refilling &

testing of joints complete as per direction of Engineer

in Charge. Internal work – Exposed on wall.

(a) 25 mm OD meter 54.00(b) 32 mm OD meter 750.00(c) 40 mm OD meter 900.00(d) 50 mm OD meter 130.00(e) 75 mm nominal inner dia Pipes meter 110.00

37

Providing and fixing G.I. pipes complete with G.I.

fittings and clamps, including cutting and making good

the walls etc. (rising main)

(a) 65 mm dia. nominal bore meter 90.00(b) 80 mm dia. nominal bore meter 150.00

38

Providing, fixing, testing and commissioning etc. of G.I.

Pipes of all diametres complete with G.I. fittings and

clamps including painting with anti corrosive bitumastic

paint etc., including trenching and refilling etc.

(external work)

(a) 80 mm nominal bore Heavy Duty metre 750.00(b) 100 mm nominal bore Heavy Duty metre 135.00

39

Making connection of G.I. distribution branch with G.I.

main 50 mm to 80 mm nominal bore by providing and

fixing tee, including cutting and threading the pipe etc.

complete

each 1.00

40

Providing and fixing ball valves (Brass) of approved

quality with high pressure plastic floats,25mm nominal

diametereach 3.00

41

Providing and fixing brass full way valve with hard

chrome plated ball inside PTFE (Teflon) seat & ring

with chrome plated centre handle with female BSP

threads complete in all respects.( Make Zoloto or

equivalent)

(a) 25 mm dia. nominal bore each 12.00(b) 32 mm dia. nominal bore each 45.00(c) 40 mm dia. nominal bore each 70.00(d) 50 mm dia. nominal bore each 25.00(e) 65 mm dia. nominal bore each 4.00(f) 80 mm dia. nominal bore each 8.00

Page 44: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

42

Providing and fixing square mouth SW gully traps

grade-A complete with C.I. grating brick masonry

chamber with bricks of class designation 75 and water

tight C.I. cover with frame of size 300 x 300 (inside) the

weight of cover to be not less than 4.50kg and frame to

be not less than 2.70kg as per standard design 180 x

150 mm size P and S type with FPS bricks

each 16.00

43

Providing and fixing un-plasticised -hollow core PVC

structured wall pipes conforming to IS:16098:Part1 SN-

8 designation including jointing with all accessories

etc., complete as directed. Eco drain pipe of Suprenme

or equivalent. (Sewer Pipe)

(a) 150 mm nominal bore m 190.00(b) 200 mm nominal bore m 730.00(c) 250 mm nominal bore m 30.00(d) 315 mm nominal bore m 20.00

44

Providing an laying cement concrete 1:5:10 ( 1 cement

: 5 coarse sand : 10 stone aggregate 40mm nominal

size) upto hunches of hollow core PVC pipe including

bed concrete as per standard design.

(a) 150 mm nominal bore m 190.00(b) 200 mm nominal bore m 730.00(c) 250 mm nominal bore m 30.00(d) 315 mm nominal bore m 20.00

45

Constructing brick masonry manhole with 75 class

designation bricks in cement mortar 1 : 5 ( 1 cement :

5 coarse sand) R.C.C. top slab with 125mm thick

RCC in proportion 1 : 2 : 4 ( 1 cement : 2 coarse sand :

4 graded stone aggregate 20 mm nominal size),

125mm thick RCC bed concrete 1:2:4 mix ( 1 cement :

2 coarse sand: 4 graded stone aggregate 20 mm

nominal size) with reinforcement, inside plastering 12

mm thick with cement mortar 1: 3 (1 cement : 3 coarse

sand ) finished with a floating coat of neat cement and

making channels in cement concrete 1 : 2 : 4 mix ( 1

cement : 2 coarse sand : 4 graded stone aggregate 20

mm nominal size) neatly finished complete as per

design but excluding the cost of reinforcement but

including the cost of centering and shuttering.

(a) Inside size 90 cm x 80 cm and 60 cm deep

including circular FRP composite manhole cover with

frame (heavy duty) 530 mm dia With F.P.S. bricks.each 23.00

Page 45: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

(b) Inside size 120 cm x 90 cm and 90 cm deep

including circular FRP composite manhole cover with

frame (heavy duty) 530 mmdia With F.P.S. bricks.each 30.00

(c) Extra depth for manhole of size

120cmX90cmX90cmm 25.00

46

Making connection of drain or sewer line with existing

manhole including breaking into and making good the

walls floors with cement concrete 1:2:4 ( 1 cement : 2

coarse sand : 4 grade stone aggregate 20mm nominal

size),cement plastered on both sides with cement

mortar 1:3 (1 cement: 3 coarse sand) finished with a

floating coat of neat cement and making necessary

channels for drain etc.250-300mm dia

each 2.00

47

Constructing brick masonry gully chamber 50 x 45 x 60

cm with bricks of class designation 75 with 500 x 450

mm C.I. horizontal gratings with frame complete as per

standard design with F.P.S. brick

each 16.00

BORE WELL

48

Boring/drilling bore well of required dia for casing/

strainer pipe, by suitable method prescribed in IS: 2800

(part I), including collecting samples from different

strata, preparing and submitting strata chart/ bore log,

including hire & running charges of all equipments,

tools, plants & machineries required for the job, all

complete as per direction of Engineer-in-charge, upto

90 metre depth below ground level.

(a) 300 mm dia Metre 180.00

49

Boring/drilling bore well of required dia for casing/

strainer pipe, by suitable method prescribed in IS: 2800

(part I), including collecting samples from different

strata, preparing and submitting strata chart/ bore log,

including hire & running charges of all equipments,

tools, plants & machineries required for the job, all

complete as per direction of Engineer -in-charge,

beyond 90 metre & upto 150 metre depth below

ground level.

(a) 300 mm dia Metre 80.00

50

Gravel packing in tubewell construction in accordance

with IS: 4097, including providing gravel fine/ medium/

coarse, in required grading & sizes as per actual

requirement, all complete as per direction of Engineer-

in-charge.

Cum 36.80

Page 46: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

51

Development of tube well in accordance with IS : 2800

(part I) and IS: 11189, to establish maximum rate of

usable water yield without sand content (beyond

permissible limit), with required capacity air

compressor, running the compressor for required time

till well is fully developed, measuring yield of well by "V"

notch method or any other approved method,

measuring static level & draw down etc. by step draw

down method, collecting water samples & getting

tested in approved laboratory, i/c disinfection of

tubewell, all complete, including hire & labour charges

of air compressor, tools & accessories etc., all as per

requirement and direction of Engineer-in-charge.

Hour 144.00

52

Providing and fixing Bail plug/ Bottom plug of required

dia to the bottom of pipe assembly of tubewell as per

IS:2800 (part I).

(a) 200 mm dta Each 2.00

53

Providing and fixing M.S. clamp of required dia to the

top of casing/ housing pipe of tubewell as per IS: 2800

(part I), including necessary bolts & nuts of required

size complete.

(a) 200 mm clamp Each 2.00

54

Supplying, assembling, lowering and fixing in vertical

position in bore well, unplasticized PVC medium well

casing (CM) pipe of required dia, conforming to IS:

12818, including required hire and labour charges,

fittings & accessories etc. all complete, for all depths,

as per direction of Engineer -in-charge.

(a) 150 mm nominal size dia Rm 120.00(b) 200 mm nominal size dia Rm 80.00

Total Amount of Part -B =

Page 47: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item

no.

Description Unit Quantity Rate in figure (Rs.) Rate in words Total Amount(Rs.)

1

Earth work in excavation by mechanical

means (Hydraulic excavator) / manual

means over areas (exceeding 30cm in

depth. 1.5m in width as well as 10 sqm

on plan) including disposal of excavated

earth, lead upto 50m and lift upto 1.5m,

disposed earth to be levelled and neatly

dressed.

All types of soil cum 500

2

Earth work in filling for site preparation

with approved quality of earth including

filling the portion within plinth area upto

the formation level, peripheral apron &

drains etc. complete upto formation

level. in layers not exceeding 20 cm in

depth including watering, ramming,

consolidating to the acceptable density

and dressing complete as directed

including obtaining earth and removal of

top vegetation, dressing the surface

upto proper grade and slope. (The rate

shall be inclusive of providing earth

including all leads and lifts, payment of

land compensation for obtaining earth,

payment of royalty and taxes etc. The

payment will be made in profile

measurement)

a)

With the earth from outside the campuscum 50000

Bill of Quantity

Name of Work: Construction of Research Park at IITG Campus.

PART - C Site Development

Page 48: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

2

Providing & laying grass turf with earth

50mm to 60mm thickness of existing

ground prepared with proper level and

ramming with tools wooden and than

rolling the surface with light roller make

the surface smoothen and light watering

the same, with sprinkler and

maintenance for 30 days or more till the

grass established properly as per

direction of officer in charge.

sqm 5000

3

Providing and laying cement concrete in

footings and bases for column in string

or lacing courses, parapets, copings,

bed blocks, anchor blocks, plain window

sills & the like upto floor two level

excluding the cost of centering,

shuttering but including finishing the

exposed surface with cement mortar

1:3 (1 cement : 3 fine sand ) with

a

with mix 1:3:6 ( 1, cement : 3, coarse

sand : 6, graded stone aggregate 20mm

nominal size )

Cum 100

b

with mix 1:2:4 ( 1, cement : 2, coarse

sand : 4, graded stone aggregate 20mm

nominal size )

Cum 180

4

Centering and shuttering including

strutting, propping etc., & removal of

form at all heights for : Foundations,

footings, bases of columns, mass

concrete , precast shelves etc.

sqm 600

5

Random rubble masonry with hard

stone in foundation and plinth including

leveling up with cement concrete 1:6:12

(1 cement : 6 coarse sand : 12 graded

stone aggregate 20 mm nominal size)

at plinth level with cement mortar 1:6 (1

cement : 6 coarse sand) including

providing weep holes with 50mm PVC

pipes and making good the same as

directed.

cum 500

Page 49: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

6

Random rubble masonry with hard

stone in super structure above plinth

level and upto floor two level, including

leveling up with cement concrete 1:6:12

(1 cement : 6 coarse sand : 12 graded

stone aggregate 20 mm nominal size)

including providing weep holes with

50mm PVC pipes and making good the

same as directed.

cum 750

Approach Road

7

Preparation and consolidation of sub

grade with power road roller of 8 to 12

tonne capacity after excavating earth to

an average of 22.5 cm depth, dressing

to camber and consolidating with road

roller including making good the

undulations etc. and re-rolling the sub

grade and disposal of surplus earth with

lead upto 50 metres.

Sqm. 4550

Construction of granular sub-base by

providing close graded Material

conforming to specifications, mixing in a

mechanical mix plant at OMC, carriage

of mixed material by tippers to work

site, for all leads & lifts, spreading in

uniform layers of specified thickness

with motor grader on prepared surface

and compacting with vibratory power

roller to achieve the desired density,

complete as per specifications and

directions of Engineer-in-Charge.

With material conforming to Grade-II

(size range 53 mm to 0.075 mm )

having CBR Value-25

Cum 180

Page 50: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

8

Providing, laying, spreading and

compacting stone aggregates of

specific sizes to water bound macadam

specification including spreading in

uniform thickness, hand packing, rolling

with 3 wheels steel/ vibratory roller 8-10

tonnes in stages to proper grade and

camber, applying and brooming

requisite type of screening/ binding

materials to fill-up the interstices of

coarse aggregate, watering and

compacting to the required density.

(boulder will be issued free of cost

inside the campus)

a

By mechanical means : Hand broken

metal from blasted boulder grading-I

90mm to 45mm using screening Type-A

(13.2mm aggregate)

cum 360

b

By mechanical means : Hand broken

metal from blasted boulder grading II

63mm to 45mm using screening Type-B

(11.2mm aggregate)

cum 240

c

By mechanical means : Hand broken

metal from blasted boulder grading III

53mm to 22.4mm using screening Type-

B (11.2mm aggregate)

cum 180

9

Providing and applying tack coat with

bitumen emulsion at the rate of 0.50 kg

per sqm on the prepared bituminous/

granular surface cleaned with broom

sqm 2392

10

Providing, laying and rolling of close-

graded premix surfacing material of

20mm thickness composed of 11.2 mm

to 0.09mm aggregates using

penetration grade bitumen to the

required line, grade and level to serv as

wearing course on a previoulsy

prepared base, including mixing in a

suitable hot mix plant laying and rolling

with a smooth wheeled roller 8-10 tonne

capacity, and finishing to required level

and grad.

sqm 2392

Page 51: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

11

Providing and laying seal coat sealing

the voids in a bituminous surface laid to

the specified levels, grade and cross fall

using type A seal coats (11.2mm to

0.09mm).

sqm 2392

12

Providing and fixing following pipes in

ground for cable crossing in road/

paved areas including excavation, back

fillilng, jointing with sockets etc. as

required.

a 100 mm. GI Pipe (medium) M 100

b 50 mm G.I.pipe (medium) M 100

Internal Foot path

13

Providing and laying interlocking

precast cement concrete paver of

approved design and compressive

strength of 300kg/sqcm laid on a bed of

40mm thick coarse sand including filling

the joints with local sand complete

80mm

sqm 3000

14

Providing and laying factory made

chamfered edge Cement Concrete

paver blocks In foot path, park & lawns

driveway or light & traffic parking etc. of

required strength, thickness & size/

shape, made by table vibratory method

using PU mould, laid in required colour

& pattern over 50mm thick compacted

bed of course sand, compacting and

proper embedding/laying of inter locking

paver blocks into the sand bedding

layer through vibratory compaction by

using plate vibrator, filling the joints with

sand and cutting of paver blocks as per

required size and pattern, finishing and

sweeping extra sand, all complete as

per manufacturer's specifications &

direction of Engineerin-

Charge.

Page 52: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

a

80mm thick Cement concrete paver

block of M-30 grade with approved

colour, design & pattern.

Sqm 2098

b

80mm thick Cement concrete paver

block of M-40 grade with non colour,

design & pattern for provition of Grass

growth into the holes.

Sqm 1178

STORM WATER DISPOSAL

15

Providing and laying non-pressure NP3

class RCC pipes and collar jointed with

stiff mixure of cement morter in the

proportion of 1:2 (1 cement : 2 fine

sand) inccluding testing of joints etc.,

complete.

a 450mm dia metre 50

b 600mm dia metre 50

c 900mm dia metre 30

d 1200mm dia metre 30

16

Brick work with bricks of class

designation 75 in foundation & plinth in

cement mortar 1:6 (1 cement : 6 coarse

sand) including curing.

cum 320

17

12mm thick, cement plaster finished

with a floating coat of neat cement of

1:4(1 cement: 4 coarse sand).

Sqm 1800

18

Providing and fixing G.I. chain link fabric

fencing of required width in mesh size

50x50 mm including strengthening with

2 mm dia wire or nuts, bolts and

washers as required complete as per

the direction of Engineer-in-charge.

Made of G.I. wire of dia. 4 mm Sqm 31

19

Providing and laying non-pressure NP2

class (light duty) R.C.C. pipeswith

collars jointed with stidd mixture of

cement mortar in the proportionof 1:2 (1

cement : 2 dine sand) including testing

of joints etc. complete :

a 150 mm dia. R.C.C. pipe m 50

b 250 mm dia. R.C.C. pipe m 150

Total of Part-C

Page 53: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item

no.

Description Unit Quantity Rate in figure (Rs.) Rate in words Total Amount(Rs.)

Sub-head -I Hydrants & Spinklers

1 Supplying and Fixing Single Headed Internal Hydrant

Valve oblique pattern with intantanneous S S

coupling of 63 mm dia with cast iron wheel ISI marked,

conforming to IS: 5290 (Type A), with 80 mm dia flanged

inlet,with ABS cap and chain complete with all

accessroies etc. as required.

Make : GETECH/NEWAGE/SAFEX each 8

2 Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15

M long complete with instantaneous type Gun Metal 3 mm dia

ISI Marked male & female couplings (IS:903) bound & riveted

to hose pipes with copper rivets and copper wire complete as

reqd.

( MAKE: NIRMAL RUBBER/NEWAGE/BRG) each 16

3 Supplying and fixing 63mm dia, S S Branch Pipe with

16/20mm dia copper nozzle confirming to IS : 903 suitable

for instantaneous connection, interconnect hose pipe,

coupling as required. (Type A) as required.

MAKE:GETECH/NEWAGE/SAFEX each 8

4Supplying and Fixing First Aid Hose Reel, wall mounting

swinging type complete with drum & bracket of MS

construction, spray painted in Post office Red, confirming to

IS 884/1995 with upto date amendments, complete with the

following as required. 36 Meter long 20 mm dia water

hose Thermoplastic (Textile reinforced) Type - 2 as per IS :

12585 20 mm dia gun metal globe valve & nozzle. Drum and

brackets for fixing the quimpments on wall.

Connection from riser with stop valve (gun metal) & M.S. Pipe

MAKE : GETECH/NEWAGE/SAFEX each 16

Bill of Quantity

Name of Work: Construction of Research Park at IITG Campus.

PART - C Site Development

Page 54: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

5Supplying and Fixing of Weather Proof Hose Cabinet

suitable for external yard hydrant / FBIC fabricated out of 2

mm thick M.S. sheet with 4

mm thick glazed glass door in front having locking

arrangements, suitable to accommodate external hydrant

with valve, hose reels, branch

pipe / FBIC with all the necessary pipes, accessories,

fittings etc., mounted on wall or raised brick platform and

duly painted with PO Red externally and white internally with

synthetic enamel paint, sign writing etc. complete in all

respects as required at site and having minimum following

dimensions. 900 mm x 600 mm x 450 mm deep

MAKE:GETECH OR SELF FEBRICATED each 16

6 Providing, Fixing, Testing and Commissioning of

Sprinkler Installation Control Valve of Cast

iron body and brass / bronze working parts

comprising of water motor, alarm, bronze seat

clapper and clapper arm, hydraulically driven

mechanical gong bell to sound continuous alarm

when the Sprinkler system activates, pressure

gauges, emergency releases, strainer, pressure

switch, cock valve complete with drain valve and

bypass, test control box, ball valves, MS pipe of

required size, flanges, orifice plate, gasket etc. of

size 150 mm dia, as required.

MAKE:GETECH/NEWAGE/SAFEX each 4

7 Providing and Fixing 15 mm dia gunmetal / brass

quartzoid type Sprinkler Head with quartz bulb

and set to operate at specified temperature.

MAKE:GETECH/NEWAGE/SAFEX

a Pendent / Upright type, 68 C, Chrome plated each 320

b Side wall 68 C, Chrome plated each 75

Sub Head - II Piping, Valves and Accessories

Page 55: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

8 Providing, Laying, Testing and Commissioning of 'B' class (

Medium ) MS pipe on surface confirming to IS 3589 and

1239 including cutting and welding with fittings like elbows,

reducer, hanger, tees, flanges, tapers, nuts bolts, gaskets

etc., fixing the pipe on the wall / ceiling with suitable

clamps and painting with two coats of synthetic enamel

paint after primer coat of required shade, cutting hole

and chase in brick wall / RCC slab and making good the

same etc. complete as required.

MAKE: TATA,JINDAL,NEZONE

a 200 mm dia mtr. 15

b 150 mm dia mtr. 415

c 80 mm dia mtr. 75

d 65 mm dia mtr. 230

e 50 mm dia mtr. 122

f 40 mm dia mtr. 10

g 32 mm dia mtr. 152

h 25mm dia mtr. 450

j 20mm dia mtr. 60

9 Supplying, Installation, Testing and

Commissioning of cast iron sluice valves of PN

1.6 rating flanged at both ends of following sizes

complete with rubber insertion, nuts, bolts and

washers etc. as required.

MAKE: KARTAR,AUDCO,SANT

a 200 mm dia each 4

b 150 mm dia each 4

c 100 mm dia each 8

d 80 mm dia each 8

10 Supplying, Installation, Testing and Commissioning

of butterfly valves of PN 1.6

rating of following sizes with nitrile seat and stainless steel

stem with lever/gear operation and cast iron body in powder

coated finish for fire fighting application complete in all

respects as required.

MAKE: KARTAR,AUDCO,SANT

a 150 mm dia nos. 4

b 100 mm dia nos. 4

c 80mm dia nos. 8

d 65 mm dia nos. 8

e 50 mm dia nos. 4

Page 56: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

11 Providing, Installation, Testing and

Commissioning of double flanged cast iron Non-Return

Valve, PN 1.6 of following sizes confirming to IS :

5312 complete with rubber gasket, Gl bolts, nuts, washers

etc. as required.

MAKE: KARTAR,AUDCO,SANT

a 200 mm dia each 2

b 150 mm dia each 4

c 80 mm dia each 4

12 Providing, Installation, Testing and

Commissioning of forged brass / Gun Metal Ball

Valves with brass body chrome plated of following

sizes as required.

MAKE: KARTAR,AUDCO,SANT

a 50mm dia each 6

b 25mm dia each 16

13 Supply, Installation, Testing and Commissioning of 100 mm

dia Bourden type, Stainless Steel dial type Pressure Gauge

including brass isolation valve and siphon pipe having

caliberation of 0 -16 Kg / cm2

MAKE:H.GURU/FEBEC each 8

14Supplying and Fixing of Fire Man's axe with heavy

insulated rubber as per standard conforming to IS 926

MAKE:GETECH/NEWAGE/SAFEX each 16

15 Constructing masonary chamber for external sluice valve

of 90 x 90 x 100 cm, inside finish with II class

designation brick work in cement mortar 1:5 (1 cement :

5 fine sand) for sluice valve, with C.I. main hole cover &

frame of 600 mm dia. and RCC top slab ( 1:2:4 mix, 1 cement:

2 coarse sand : 4 graded stone aggregate 20 mm nominal

size) necessary excavation foundation concrete 1:5:10

(1 cement : 5 fine sand : 10 graded stone aggregate

40 mm nominal size) inside plastering with cement

mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick

finished with a floating coat of neat cementcomplete as

required. each 8

B EXTERNAL FIRE FIGHTING SYSTEM (MAIN PUMP).

Page 57: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

16 Supply, Erection, Testing & commissioning of

Electrical Motor Driven Pump centrifugal end

section type pump complete with bronze

impeller, mechanical seal capable of delivering

2280 liters/minute against a total head of 70

metres, induction motor suitable for 415V, 50 Hz,

AC supply min. 60 HP with speed of 2900 RPM ,

TEFC type conforming to IP: 55, flexible coupling,

coupling guard. Common bedplate fabricated

from mild steel channel, vibration pads, isolation

arrangement & RCC foundation. MAKE :KIRLOSKAR OR

EQUIV.

set 1

17 DIESEL ENGINE DRIVEN FIRE PUMP:

Supply, Erection, Testing & commissioning of

Diesel Engine Driven Pump Horizontal end

section, centrifugal type pump complete with

bronze impeller, mechanical seal capable of

delivering 2280 liters/minute against a total

head of 70 metres, Diesel Engine Min.Cap. of

93 BHP with speed of 1800 RPM , flexible

coupling, coupling guard. Common bed plate

fabricated from mild steel channel, starter motor,

batteries, battery charger & cabling, fuel piping,

instrumental panel, exhaust piping with

residential type silencer, cooling arrangements

including 200 Litres Diesel Tank Complete,

vibration pads, isolation arrangement, heat

exchanger & RCC foundation.

MAKE: KIRLOSKAR OR EQUIV. set 1

18 JOCKEY PUMPS:

Supply, Erection, Testing & commissioning of Jockey

Pump Horizontal end section single stage centrifugal

type pump complete with bronze impeller, mechanical

seal capable of delivering 180 liters/minute against a total

head of 70 metres, induction motor suitable for 415V, 50 Hz,

Min 15 HP with 2900 RPM, TEFC type conforming to IP: 55,

flexible coupling, coupling guard. Common bedplate

fabricated from mild steel channel, vibration pads,

isolation arrangement & RCC foundation.

MAKE:KIRLORKAR OR EQUIV. set 1

19 TERRACE PUMPS:

Page 58: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Supply, Erection, Testing & commissioning of Terrace

Pump Horizontal end section single stage centrifugal

type pump complete with bronze impeller, mechanical

seal capable of delivering 27 (M3/Hr) against a total head of

30 metres, induction motor suitable for 415V, Min 5.5KW

with 2900 RPM, TEFC type

conforming to IP: 55, flexible coupling, coupling guard.

Common bedplate fabricated from mild steel channel,

vibration pads, isolation

arrangement & RCC foundation.

MAKE:KIRLORKAR OR EQUIV. 2

20 SITC of industrial type pressure switch having

1/4" BSP(F) connection IP:32 enclosure

protection, phosphor bronze bellows as sensing

element, SDPT contact system, switch rating 6A

Inductive/10A resistive 380 V AC, 0.2A

Inductive/10A resistive 250V DC suitable for

maximum pressure range of 230 PSI with

isolation cock and interconnecting cables using

copper conductor between pressure switch and

panels completed as required.

MAKE:INDFOS OR DANFOSS nos. 4

21 Supply, Erection, Testing & commissioning of Air

Vessel made of 10 mm M.S. Sheet size 450 x

2000 mm including supply & fixing of Gun metal

32 mm dia Air release Valve, 32 mm dia Gun

Metal gate valve, 40 mm dia gun metal gate

valve including 2Mts of M.S 40 mm dia G. I

(Heavy pipe for drainage and 1 no. 65 mm dia

Butterfly valve with all necessary accessories as

per IS 2825

MAKE:GETECH / SELF FEBRICATED. nos. 5

22 PIPING ABOVE GROUND FOR EASY MAINTENANCE

Supply, Erection, Testing & commissioning of

M.S pipe (Medium) ISI marked 1239-part-1 and

ISI : 3589 including cutting, welding/threading

with accessories like tees, elbows, flanged joints, reducers,

rubber gaskets, nuts & bolts including fixing the pipe with

suitable clamps/bracket,

complete as required including painting of one coat of red

oxide & 2 coats of P.O. red paint

MAKE: TATA,JINDAL,NEZONE.

a 80 mm dia mtr. 40

Page 59: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

b 150 mm dia mtr. 300

23 Supply, Erection, Testing & commissioning of Single

headed hydrant S S valves

conforming to ISI: 5290 with flanged inlet with 63 mm female

instantaneous of gun metal coupling with blank cap & chain,

nuts, bolts, washers &

5mm thick rubber gasket etc.

MAKE:GETECH/NEWAGE/SAFEX nos. 26

24 Supply, Erection, Testing & commissioning of 63 mm dia, 15

M long RRLhose pipe conforming to ISI-636 type A Mark fire

hose pipe conforming to IS 901 mark with S S male &

female coupling wire wound with the pipe

MAKE:GETECH/NEWAGE/SAFEX nos. 26

25 Supply, Erection, Testing & commissioning of S Sshort

branch pipes conforming to ISI

spec 903 with 16 mm dia nozzle.

MAKE:GETECH/NEWAGE/SAFEX nos. 8

26 Supply & Erection of M.S.Fire Hose Box of size 900 x 600x

450 mm approx.) fabricated from 16 SWG. M.S. Sheet of

fully welded construction with hinge front door with locking

arrangement & partially glazed with 5 mm thick

glass

powder coated fire red finish paint with Fire Hose Box

written on the front side of the glass for internal hydrants to

house 2 nos. hose pipes, 1 no. Branch pipe, 1 no. Hose

reel & Landing valve 1 No.

MAKE:GETECH/NEWAGE/SAFEX nos. 8

27 Supply, Erection, Testing & commissioning of

Drawl of connection with CI foot valve 150 mm

dia (for fire tank)and 3 Meter G.I. 100 mm dia (H)

pipe, nuts, bolts, washers & 5mm thick rubber

gasket etc.

MAKE:GETECH/NEWAGE/SAFEX nos. 1

28 Fire brigade Two Way Inlet Valve with 2 nos.

G.M 63 mm dia Male instantaneous coupling with

100 mm flanged out let connection and built in

check valves

MAKE:GETECH/NEWAGE/SAFEX nos. 4

Main Fire Pump Panel

Page 60: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

29 Fabricating, supplying, erection, testing and

commissioning of cubicle type floor mounted panel made

from 14 CRCA Sheet complete with contactors,Auxillary

contacts ,indicating lamps,Ammeters with selector

switches, voltmeters with selector switches,fuses,

automatic delta type motor starter including connections

complete as required for 1 No Fire hydrant and sprinkler

pump, 1 No. Jockey pump, 1 No Battery charger and 1

Set of Battery complete in all respect including

neccessary control wiring as per the details given below:

Incoming

1) 500 Amps MCB - 1 No.

2) Voltmeter (0-500) V (size 96mm x 96mm) - 1No.

3) Voltmeter Selector Switch - 1 No.

4) Indication Lamps (LED type) -1 sets (1 set of 03

Nos.RYB)

5) Ammeters(0-200A) - 1 No.

6)Ammeter selector switch -1 No

7)Current transformer (300/5A) -3Nos

8)Bus bar chamber with 900 Amps Aluminim bus bar

,suitable for 3 phase and neutral system - 01set.

9)Required number of Auxillary contacts

set

Page 61: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Outgoing

1)200 Amps MCB , -2 Nos

2) 100 Amps MCB - 1 No

3) Fully Automatic delta starter (60 hp ) with LED

illuminated ON-OFF push button -2Nos.

4) Fully Automatic delta starter (15hp ) with LED

illuminated ON-OFF push button - 1 No.

5)Auxillary contactors for main, sprinkler and

jockey pumps

6) Auto/ manual selector switch with control

wiring for main, sprinkler and jockey pump

7) Annunciator with hooter, accept/ reset push

button with control wiring

8) Currect Transformer (200/5A) --6 Nos

9) Currect Transformer (100/5A) --3 Nos

10) Ammeter 0-150 --3 Nos

11) Volt Meter 0-500--3 Nos

12) Single phase preventer--3 Nos

13) 3 Set Phase indication Lamps with Phuses

Control Panel Engine

a) 15 Amp Battery charges with trickle and boost

facility

b) 0-32 volts/ meter--1 No

c) 0-15 Amps ammeter--1 No

d) Auto Starting contractor with relay

e) Auto/ Manual selector switch with push button

for manual start--1 No

f) 63 MCB - 1No

g) Buzzer--1 N0

h) Indication Lamp--3 No

I) Push Button--2 No30 TERRACE PUMP PANEL to start the Terrace Pump

Automaic Nos 2

31 Supply of fire buckets Set of four nos. with MS

stand with sand etc. as required. Nos. 20

set 1

Page 62: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

32 Supply, Installation, Fixing of ABC stored Pressure Fire

Extinguisher with built – In Pressure Gauge to know the

Ready ness of the Extinguisher Squeeze Grip Handle as per

IS:15683 with ISI mark.

(6 kg capacity)

BRAND : GETECH / MINIMAX/ SAFEX Nos 46

33 Supply, Installation, Fixing of CARBON DIOXIDE Fire

Extinguisher confirming to IS: 15683 with ISI Mark.(4.5

LITERS)

BRAND: GETECH /MINIMAX / SAFEX Nos 16

34 Manual Call Point & Hooter each floor area. Make:Agni

Suraksha Nos 16

35 12 Zone Panel for Manual Call Box & Hooter to identify the Nos 4

Location/ floor area Zone wise.Make :Agni Suraksha

36 Exit Board Auto Glow type for easy evcuation floor wise. Nos 24

37Providing & fixing angle iron (40mm x 40mm x 5mm) door

frame and M.S sheet (2mm thick) sum glass shutter of size

2.1 mtr. X 1.2 mtr. (N.S) with 25 mm x 3 mm angleframe all

around & stiffenced in between i/c hinges, handle, locking

arrangement, painting with approved synthetic enamle paint

i/c sign writing on glass at internal hydrant including providing

& fixing M.S. Sheet 2 mm thick on remaing portion above door

to close opening i/c painting etc. as required. each 44

Total of Part -D

Page 63: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item no. Description Unit Quantity Rate in figure (Rs.) Rate in words Total Amount(Rs.)

1

Supply, installation, testing & commissioning of short -

circuit - Isolators.

Nos 49

2

Supply, installation, testing & commissioning of Control

Modules (CMX) for controlling Hooters/ speakers, Strobe

(Flasher) Lamps, Manual Call Points (MCP), etc.

Research Block Each 12

3

Supply, installation, testing & commissioning of 'Rise'

type Heat Detectors, approved make, with Operating

Temperature of ( - ) 10OC to ( + ) 70

OC and OPERATING

VOLTAGE OF 18 TO 28 V D.C.

Research Block Each 18

4

Supply, installation, testing & commissioning of 'Rise'

type Multicriteria Detectors, approved make, with

Operating Temperature of ( - ) 10OC to ( + ) 70

OC and

OPERATING VOLTAGE OF 18 TO 28 V D.C.

Each 670

5

Supplying, fitting & fixing Base of Dectector,Model no-

B501

Each 694

6 Supplying, fitting & fixing Duck Dectector.

Research Block Each 24

7 Supplying, fitting & fixing Beam Dectector.

Research Block Each 4

8

Supply, installation, testing & commissioning of manual

push button station break glass type - Manual call points

(MCP) with MS / ABS body, with chain & hammer, and

also with Blinking facility, completely compatible with the

main Fire Alarm Panel.

Each 24

9

Supply , installation, testing & commissioning of Monitor

Modules for Manual call points - (MMX)

Research Block

Each 6

PART-D(ii) (FIRE DETECTION, ALARM SYSTEM)

Name of work: Construction of Research Park Building at IITG campus

Bill of Quantity

Research Block : FIRE DETECTION, ALARM & P.A. SYSTEM

Page 64: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

10

Supply , installation, testing & commissioning of M.S.

Junction Boxes. NOS 23

11

Supplying & laying 2 core x 1.5 sq.mm copper conductor

PVC insulated, sheathed armoured cable - ISI marked.

Rm 5347

12 Supplying & laying Telephone wire

Research Block Rm 900

13

Supply, installation, Testing, Commissioning of Field

Handset for Both way Communication system.

Research Block Set 12

14

Supply, installation, Testing, Commissioning of Fire

Fighter Telephone Jack.

Research Block Each 12

15

Supply, installation, Testing, Commissioning of

Telephone Module.

Research Block Each 12

16

Supply, installation, Testing & Commissioning of Digital

Voice Evacuaition.

Research Block Set 12

17

Supply, installation, Testing & Commissioning of 50 Wat

Amplifer.

Research Block Each 1

18

Providing, Installing, Testing & Commissioning Horn with

Strobe, complete.

Research Block Each 12

19

Providing, Installing, Testing & Commissioning Relay

Moudle, all complete.

Research Block Each 12

20

Sprinklers - Supply, installation, testing & commissioning

of open type spray nozzles ( sprinkler jets)) - pendent

type - with 1/2" inch inlet connection (male threaded)

with deflector and quartzoid bulb of (MAKE :- "Tyco" /

"Viking"/ "Central" - Model :ELO-16 / "Crawlie & Ray" /

"Omex"), Conventional "Pendent" - "UL" Listed

Sprinklers. (For Sprinkler system)

(a)

("Pendent" only - in all Floors below False Ceiling / True

ceiling) Each 399

(b)

("Up-Right" only - in respective Floors, above False

Ceiling only). Each 335

Gross Total (Research Block)

Page 65: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

FIRE DETECTION, ALARM & P.A. SYSTEM

1

Supply, installation, testing & commissioning of short -

circuit - Isolators.

Nos 23

2

Supply, installation, testing & commissioning of Control

Modules (CMX) for controlling Hooters/ speakers,

Strobe (Flasher) Lamps, Manual Call Points (MCP), etc.

Each 8

3

Supply, installation, testing & commissioning of 'Rise'

type Heat Detectors, approved make, with Operating

Temperature of ( - ) 10OC to ( + ) 70

OC and OPERATING

VOLTAGE OF 18 TO 28 V D.C.

Kitchen Each 6

4

Supply, installation, testing & commissioning of 'Rise'

type Multicriteria Detectors, approved make, with

Operating Temperature of ( - ) 10OC to ( + ) 70

OC and

OPERATING VOLTAGE OF 18 TO 28 V D.C.

Nos 330

5

Supplying, fitting & fixing Base of Dectector,Model no-

B501

Nos 342

6 Supplying, fitting & fixing Duck Dectector.

Apartment Block

Kitchen Nos 6

7

Supply, installation, testing & commissioning of manual

push button station break glass type - Manual call

points (MCP) with MS / ABS body, with chain &

hammer, and also with Blinking facility, completely

compatible with the main Fire Alarm Panel.

Apartment Block

Each 20

8

Supply , installation, testing & commissioning of Monitor

Modules for Manual call points - (MMX)

Apartment Block

Each 8

9

Supply , installation, testing & commissioning of M.S.

Junction Boxes. NOS 20

Apartment block (FIRE DETECTION, ALARM SYSTEM)

Page 66: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

10

Supplying & laying 2 core x 1.5 sq.mm copper conductor

PVC insulated, sheathed armoured cable - ISI marked.

Rm 3581.3

11 Supplying & laying Telephone wire

Apartment Block Rm 400

12

Supply, installation, Testing, Commissioning of Field

Handset for Both way Communication system.

Apartment Block Set 8

13

Supply, installation, Testing, Commissioning of Fire

Fighter Telephone Jack.

Apartment Block Each 8

14

Supply, installation, Testing, Commissioning of

Telephone Module.

Apartment Block Each 8

15

Supply, installation, Testing & Commissioning of Digital

Voice Evacuaition.

Apartment Block Set 8

16

Supply, installation, Testing & Commissioning of 50 Wat

Amplifer.

Apartment Block Set 1

17

Providing, Installing, Testing & Commissioning Horn with

Strobe, complete.

Apartment Block Each 8

18

Providing, Installing, Testing & Commissioning Relay

Moudle, all complete.

Apartment Block Each 8

19

Sprinklers - Supply, installation, testing & commissioning

of open type spray nozzles ( sprinkler jets)) - pendent

type - with 1/2" inch inlet connection (male threaded)

with deflector and quartzoid bulb of (MAKE :- "Tyco" /

"Viking"/ "Central" - Model :ELO-16 / "Crawlie & Ray" /

"Omex"), Conventional "Pendent" - "UL" Listed

Sprinklers. (For Sprinkler system)

(a)

("Pendent" only - in all Floors below False Ceiling / True

ceiling)

Each 222

(b)

("Up-Right" only - in respective Floors, above False

Ceiling only).

Each 136

20

Providing, Installing, Testing & Commissioning of cyling /

wall mounted Baffle Speaker of 6 watts each, complete.

Page 67: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Apartment Block Each 40

Gross Total (Apartment Block)

Page 68: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item no. Description Unit Quantity Rate in figure (Rs.) Rate in words Total Amount(Rs.)

1 Wiring for light point/ fan point/ exhaust fan point/ call bell

point with 1.5 sq.mm FRLS PVC insulated copper conductor

single core cable in surface / recessed medium class PVC

conduit, with modular switch, modular plate, suitable GI box

and earthing the point with 1.5 sq.mm FRLS PVC insulated

copper conductor single core cable etc. as required.

1.1 Group B Point 3.00

1.2 Group C Point 20.00

2 Wiring for circuit/ submain wiring alongwith earth wire with

the following sizes of FRLS PVC insulated copper conductor,

single core cable in surface/ recessed medium class PVC

conduit as required.

-

2.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire meter 80.00

2.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire meter 190.00

4 Supplying and fixing following modular switch/ socket on the

existing modular plate & switch box including connections but

excluding modular plate etc. as required.

-

4.1 5/6 A switch Each 1.00

4.2 15/16 A switch Each 6.00

4.3 3 pin 5/6 A socket outlet Each 1.00

4.4 6 pin 15/16 A socket outlet Each 6.00

7 Supplying and fixing following size/ modules, GI box alongwith

modular base & cover plate for modular switches in recess etc.

as required.

7.2 3 Module (100 mmX75 mm) Each 1.00

7.3 4 Module (125 mmX75 mm) Each 6.00

8 Supplying and fixing 3 pin, 5 A ceiling rose on the existing

junction box/ wooden block including connections etc. as

required.

Each 3.00

-

Bill of Quantity

Name of Work: Construction of Research Park at IITG Campus.

Part-E(Electrical works)

Basic Infra Part-A

WIRING IN STEEL & PVC CONDUIT

CHAPTER-2-MCCB, MCB & DB’S

Page 69: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

10 Supplying and fixing following way, single pole and neutral,

sheet steel, MCB distribution board, 240 V, on surface/ recess,

complete with tinned copper bus bar, neutral bus bar, earth

bar, din bar, interconnections, powder painted including

earthing etc. as required. (But without MCB/RCCB/Isolator)

-

10.1 6 way, Double door Each 1.00

11 Supplying and fixing following way, horizontal type three pole

and neutral, sheet steel, MCB distribution board, 415 V, on

surface/ recess, complete with tinned copper bus bar, neutral

bus bar, earth bar, din bar, interconnections, powder painted

including earthing etc. as required. (But without

MCB/RCCB/Isolator)

-

11.1 4 way (4 + 12), Double door Each 1.00

13 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”

curve, miniature circuit breaker suitable for inductive load of

following poles in the existing MCB DB complete with

connections, testing and commissioning etc. as required.

-

13.1 Single pole Each 18.00

13.2 Double pole Each 1.00

13.3 Triple pole and neutral Each 1.00

13.3 Supplying and fixing single pole blanking plate in the

existing MCB DB complete etc. as required.

Each 4.00

-

-

19.1 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia

including accessories, and providing masonry enclosure with

cover plate having locking arrangement and watering pipe etc.

with charcoal/coke and salt as required.

Each 41.00

19.2 Earthing with copper earth plate 600 mm X 600 mm X 3 mm

thick including accessories, and providing masonry enclosure

with cover plate having locking arrangement and watering pipe

of 2.7 meter long etc. with charcoal/ coke and salt as required.

Set 10.00

WIRING IN STEEL & PVC CONDUIT

CHAPTER -5- EARTHING

Page 70: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

19.3 Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter

below ground as strip earth electrode, including

connection/terminating with nut, bolt, spring, washer etc. as

required.(Jointing shall be done by overlapping and with 2 sets

of brass nut bolt & spring washer spaced at 50 mm)

meter 150.00

19.4 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter

below ground as strip earth electrode, including

connection/terminating with G.I. nut, bolt, spring, washer etc.

as required.(Jointing shall be done by overlapping and with 2

sets of G.I. nut bolt & spring washer spaced at 50 mm)

meter 660.00

19.5 Providing and fixing 25 mm X 5 mm copper strip on surface or

in recess for connections etc. as required.

meter 72.00

19.6 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in

recess for connections etc. as required.

meter 304.00

19.7 Providing and fixing 6 SWG dia G.I. wire on surface or in recess

for loop earthing as required.

meter 1,060.00

-

20.1 Providing and fixing of lightning conductor finial, made of 25

mm dia 300 mm long, G.I. tube, having single prong at top, with

85 mm dia 6 mm thick G.I. base plate including holes etc.

complete as required.

Each 7.00

20.2 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet

or on surface of wall for lightning conductor complete as

required.(For horizontal run)

meter 410.00

20.3 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet

or on surface of wall for lightning conductor complete as

required. (For vertical run)

meter 235.00

20.4 Providing and fixing testing joint, made of 20 mm X 3 mm thick

G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck

nuts and spring washers etc. complete as required

Each 107.50

-

21 Laying of one number PVC insulated and PVC sheathed / XLPE

power cable of 1.1 kV grade of following size direct in ground

including excavation, sand cushioning, protective covering and

refilling the trench etc. as required.

-

21.1 Upto 35 sq. mm meter 400.00

21.2 Above 95 sq. mm and upto 185 sq. mm meter 966.00

CHAPTER 6-LIGHTNING CONDUCTOR

CHAPTER 7-MV CABLE LAYING

Page 71: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

21.3 Above 185 sq. mm and upto 400 sq. mm meter 1,796.00

22 Laying of one number PVC insulated and PVC sheathed / XLPE

power cable of 1.1 kV grade of following size in the existing

RCC/ HUME/ METAL pipe as required.

-

22.1 Upto 35 sq. mm meter 66.00

22.2 Above 95 sq. mm and upto 185 sq. mm meter 76.00

22.3 Above 185 sq. mm and upto 400 sq. mm meter 40.00

23 Laying and fixing of one number PVC insulated and PVC

sheathed / XLPE power cable of 1.1 kV grade of following size

on wall surface as required.

-

23.1 Upto 35 sq. mm (clamped with 1mm thick saddle) meter 1,504.00

24 Laying and fixing of one number PVC insulated and PVC

sheathed / XLPE power cable of 1.1 kV grade of following size

on cable tray as required.

-

24.1 Upto 35 sq. mm (clamped with 1mm thick saddle) meter 2,238.00

24.2 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/

40x3mm MS flat clamp)

meter 128.00

24.3 Above 185 sq. mm and upto 400 sq. mm (clamped with

40x3mm MS flat clamp)

meter 600.00

-

25 Supplying and making end termination with brass compression

gland and aluminium lugs for following size of PVC insulated

and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV

grade as required.

-

25.1 3½ X 35 sq. mm (32mm) each 48.00

25.2 3½ X 120 sq. mm (45 mm) each 8.00

25.3 3½ X 185 sq. mm (57mm) each 16.00

25.4 3½ X 300 sq. mm (70 mm) each 56.00

25.5 4 X 10 sq. mm (25 mm) each 230.00

25.6 4 X 16 sq. mm (28mm) each 4.00

-

-

26 Providing, laying and fixing following dia G.I. pipe (medium

class) in ground complete with G.I. fittings including trenching

(75 cm deep) and re-filling etc. as required

-

26.1 50 mm dia meter 100.00

CHAPTER 14- MISC. CIVIL ITEMS

CHAPTER 9-MV CABLE JOINTING & END TERMINATION

Page 72: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

27Providing, laying and fixing following dia RCC pipe NP2 class

(light duty) in ground complete with RCC collars, jointing with

cement mortar 1:2 (1 cement : 2 fine sand) including trenching

(75 cm deep) and refilling etc. as required.

-

27.1 300 mm dia meter 300.00

1.00 MV SWITCHGEAR / POWER PANEL / DISTRIBUTION BOARDS.

1.10 POWER PANEL:

Supply, installation, testing and commissioning of cubicle type

panels as specified and shown on drawing no. WTE2233/STAGE

2/901 SHEET 1 TO 6 with :

i) Main Aluminium busbars with bar type feeder connections &

all internal wiring and connections.

ii) Earthing all components, frame etc. to a common internal

earth bar.

iii) Powder Coat painting of all sheet metal works.

iv) All accessories & supporting structure.

v) Brass glands and crimping lugs for sending and receiving

ends.

vi) All ammeters with C.T's and voltmeter and energy meters

with necessary fuses.

vii) Panel components as specified.

viii) MS base frame.

ix) All switch gear to have short circuit levels as specified.

1.1 MAIN LT PANEL each 1.00

1.2 APFC PANEL(700KVAR) each 2.00

1.3 LAB BLOCK MAIN PANEL each 1.00

1.4 APARTMENT BLOCK MAIN PANEL each 1.00

1.5 FEEDER PILLAR PANEL each 1.00

1.6 UPS PANEL each 1.00

1.14 UTILITY PANEL each 1.00

2.00 MV CABLE

2.1 Supply of heavy duty 1100V grade LT XLPE insulated sheathed

& armoured cables with aluminium / copper conductors as

specified and required.

2.1.1 4C X 10sq.mm. Al. Ar. XLPE Cable rm 2,324.00

Basic Infra Part-B

Page 73: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

2.1.2 4C X 16sq.mm. Al. Ar. XLPE Cable rm 66.00

2.1.3 3.5C X 35sq.mm. Al. Ar. XLPE Cable rm 1,770.00

2.1.4 3.5C X 120sq.mm. Al. Ar. XLPE Cable rm 276.00

2.1.5 3.5C X 185sq.mm. Al. Ar. XLPE Cable rm 894.00

2.1.6 3.5C X 300sq.mm. Al. Ar. XLPE Cable rm 2,436.00

2.1.7 4C X 4sq.mm. CU. Ar. XLPE Cable rm 50.00

2.1.8 12C X 1.5sq.mm. CU.pvc control Cable rm 30.00

2.1.9 3C X 1.5sq.mm. CU. AR. XLPE Cable rm 48.00 3 INTERNAL LIGHT, CEILING AND EXHAUST FAN FITTINGS

3.1.5

Surface mounted 1200mm high effiecency 20W integrated

LED batten, with minimum 100 Lumens/Watt efficacy. CCT

6500K, CRI> 80. Luminaire driver should be Isolated and

multistage constant current type. Driver Input voltage range

of 150V to 270V ( nominal rated voltage – 240V) with

minimum 2.5KV surge protection, PF >0.90, THD <20%,

Similar to Wipro Make LL20-221-XXX-65NE1 or equivalent.each

12.00

3.1.9

Supply of Bulkhead LED enclosed in die cast Aluminium

housing for superior heat management and Polycarbinate

opul diffuser. The maximum system wattage should be 10W.

CCT 5700K, CRI> 80. Luminaire driver should be Isolated and

multistage constant current type. Driver Input voltage range

of 150V to 270V ( nominal rated voltage – 240V) with

minimum 2.5KV surge protection, PF >0.9, THD <20%,.

Luminaire should be IP65 Protected. Similar to Wipro Make

LW07-141-XXX-57-XX or equivalent.each

8.00

3.1.11 450mm sweep exhaust fan heavy duty each 3.00

5 SUBSTATION AUXILIARIES INSTALLATION -

5.1 Supply and fixing of MS chequered plate 6mm thick of different

size for covering trench inside substation area including MS

angle of section 35 x 35 x 5mm for support of plate and

necessary civil work and painting

SqM 60.00

5.2 Supply and fixing of shock treatment chart with glass and

aluminium frame on wall in Bengali, Hindi and English

each 2.00

5.3 Supply of First Aid box with all necessary materials and

medicines

each 1.00

5.4 Supply,installation of 4.5kg CO2 fire extinguisher complete with

intial charges discharge hose, horn and bracket

each 2.00

Page 74: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

5.5 Supply and fixing of fire bucket filled with sand each 8.00

5.6 Supply and erection of fire bucket stand 1500mm wide and

1000mm height, made of 50mm x 50mm x 6mm angle iron with

cross bracing and 4nos. Hook for hanging the bucket as

completed with painting (2 coats of Red paint over one coat of

red oxide primer)

each 2.00

6 EXTERNAL LIGHTING -

6.1 Supply & fixing of Top Maintainable LED Street Light luminaire

enclosed in pure polyester powder coated Pressure Die Cast

aluminium housing suitable to mounted on 55 mm OD bracket

arm. The maximum wattage of luminaire shall be 70W with

minimum system efficacy 110lm/W. Luminaire shall have two

separate compartments for LEDs and driver and both

compartments should be hermitically sealed to achieve IP 66

ingress protection. Optical compartment shall be provided with

heat resistant clear toughened glass to withstand IK 07 impact

rating, while control gear shall be provided with die cast

aluminium cover for safety. Potted LED Driver shall be SELV,

Isolated type, multistage Constant Current Constant Voltage

topology driver with proper heat sink for heat dissipation

suitable to operate in input voltage range of 100V to 300V

(nominal rated voltage – 240V) with 4 KV internal surge

protection in both CM and DM mode. Similar to Wipro make

LR02-781-XXX-57-G2 or Equivalent.

40.00

6.2 Supply & fixing of 45W top maintanable LED Post-top housed in

die cast aluminium housing and HET diffuser. Luminaire is

suitable for pole diameter of

65-75 mm. Protected with IP65 protection. CCT 5700K, CRI >70.

Similar to wipro make LP02-501-XXX-57-XX and Equivalent

4.00

Page 75: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

6.3 Supply, installation , testing & commisioning of Steel 9 Mtr GI

Octagonal Pole -Top dia -70 mm, Bottom Dia-155 mm, Section-

1 (Section Length - 7000 mm) Thick-3mm. Base Plate - 260mm x

260mm x 16mm. hole in pole at a height of 300mm above the

planting depth with Single Arm Bracket 1 Mtr long with

33.7mm OD GI Pipe and coated with two coats of black

bituminous paint through out internally and externally upto

the planting depth and the remaining portion above ground

shall be painted with two coat of aluminium painting over one

coat of red oxide primer and individual spike earthing with 8

SWG wire inclusive of civil foundation work. Foundation Bolt-

M24 x 750 mm (4Nos)

-

6.3.1 Single arm (9 MTR) no. 44.00

6.4 Supply & fixing of Junction box with clamp on street light pole /

recessed in gate pillars, comprising of 6A SP MCB with elmex

terminals suitable for terminating incoming and out going

cables of upto 3 core 10 sq.mm 1.1 kV grade armoured PVC

insulated and covered cables including bolt,nut & screws, D -

clamp etc. as complete and as directed by Engineer - in -

charge.

no. 44.00

6.5 Wiring with 3 X 1.5sqmm 600 V grade FRLS insulated flexible Cu

conductor wire from looping junction boxes at the base of the

pole to the light fittings through prelaid rigid PVC conduit, as

required to be completed in all respect and as directed by

Engineer - in - Charge.

rm 360.00

6.6 Supply and fixing of integral LED AVIATION Light with double

lamp including all necessary accessories as required.

nos 1.00

7.0 Providing and fixing following capacity 4 pole automatic on

load ON/OFF -Load changeover switches with side handle

operation, in sheet enclosure in metal board including drilling

holes in metal board, making connection , earthing the body

etc. as required.

-

7.1 100 A , 4 POLE nos -

7.2 630 A , 4 POLE nos -

18.0 TELEPHONE, CCTV, ACCES CONTROL -

Page 76: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

18.1 Supply testing commessioning of IP DIGITAL Indoor/Outdoor

Type MEGAPIXEL CAMERA-(IR Camera , 4.9 MEGAPIXEL SONY

CHIPSET LOW ILLUMINATION HIGH COLOR RESOLUTION AUDIO

MIC SUPPORT,POE SUPPORT , /MM lens, 50 mts (works in zero

Light)- video output• ONVIF technology• True day / night •

DNR, Smart IR• Up to 25m IR distance H.265 With Smart

Analytics & embedded Intelligence)

nos 65.00

18.2 Supply testing commessioning of HD NVR : Recording Unit For

Cameras 36 Channel 4K NVR - with support for 4 SATA Hard

Disk And Audio Mic Support in 36 Channels H.265 With Smart

Analytics & embedded Intelligence (1) 4K NVR WIith Preview /

Recording Resolution upto 12MP 2) Recording frame rate: 3)

SATA port: H.265 With Smart Analytics & embedded

Intelligence , 4 SATA HDD support 4)USB 2.0 Ports, VGA output,

HDMI port . 5) Support Onvif; Third-party IP cameras Supports

3G, 6) Support 15 x digital zoom in preview/ playback channel

Support IE, mobile phone remote monitoring)

nos 2.00

18.3 Supply testing commessioning of INTERCOM SYSTEM P&T Ports

: 08 ; Digital Extension : 08 ; Extension Ports : 184

nos 1.00

18.4 Supply testing commessioning of INTERCOM SYSTEM P&T Ports

: 08 ; Extension Ports : 136

nos 1.00

18.5 Supply testing commessioning of ACCESS CONTROL SYSTEM

ACCESS CONTROL WITH SINGLE LEAF LOCK ALONG WITH

ACCESSORIES , 4PC CARD PER DEVICE ,EXIT

SWITCHFINGER+CARD BASED STAND ALONE ACCESS CONTROL

WITH LOCK AND ACCESSORIES of Toshiba/Western Digital /

Seagate make

nos 24.00

18.6 Supply testing commessioning of Hard Disk Internal

Surveillance Hard Disk For Recording unit- 4TB of

Toshiba/Western Digital / Seagate make

pcs 4.00

18.7 Supply testing commessioning of Power Supply LOCAL POWER

POINT TO BE PROVIDED NEAR EACH CAMERA of GPTRON make

port 100.00

18.8 Supply testing commessioning of 8 Port Network Switch of

DLINK/REPUTED make

pcs 280.00

Page 77: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

18.9 Supply testing commessioning of 16 Port Network Switch of

DLINK/REPUTED make

pcs 2.00

18.10 Supply testing commessioning of telephone reciever of

REPUTED make

pcs 136.00

18.11 Supply testing commessioning of KTS reception phone of

REPUTED make

pcs 2.00

18.12 Supply testing commessioning of krone module for intercom of

REPUTED make

pcs 7.00

18.13 Supply testing commessioning of Desktop Computer For

Viewing Cameras from the reception for intercom of REPUTED

make

pcs 2.00

18.14 Supply testing commessioning of Camera Connectors lot 1.00

18.15 Supply & laying of Camera Network Cable rm 2,500.00

18.16 Supply & laying of Power Cable rm 1,000.00

18.17 Supply & laying Telephone cable rm 5,200.00

18.18 Supply & laying Conduit Pipe rm 8,700.00

18.19 Supply testing commessioning of Rack 6u nos 2.00

18.20 Supply testing commessioning of LED 42 INCH LED nos 2.00

18.21 Accessories for keeping camera /network switch accessories at

the place of installation

pcs 80.00

18.22 Laying Charges with accessories rm 8,700.00

18.23 Training /Installation Charges job 1.00

4.00 DIESEL GENERATOR SET

4.1 Supply, installation, testing, commissioning of DG set with

accoustic enclosure including supply and installation of exhaust

pipe with 48kg/cum density fibreglass white wool along with all

MS support structure (The insulation shall be held in position

with galvanised steel wire mesh 0.63dia and finished neatly

with 26SWG aluminium cladding) as required from engine to

residential silencer and thereafter upto termination point 3 M

above the roof level or as per lattest PCB norms and as

specified in equipment data sheet.

4.1,1 160 KVA (with Auto mains failure Panel) each 1.00

4.1.2 1250 KVA each 1.00

4.1.2.1 1250 KVA Auto mains failure, Auto load sharing & Auto

synchronization Panel

DIESEL GENERATOR

Page 78: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

4.1.3 500 KVA (with Auto mains failure Panel) each 1.00

7.00 LIFT7.1 Supply, installation testing and commissioning of lifts of

maximum rated load 15 passenger, speed 1.75mps of triplex

system travelleing for G +10 floors of travel height. Hair line

stainlesssteel venyle floor finish, centre opening automatic

door of fire retardent capacity not less than 2hours without

machine room, gear less system inclusive of all accessories,

gadgets, emergency light car operating panel indicator door

close and open button alarms, colour LCD display, emergency

phone, handicapped COP, braille push buttons, star light ceiling

finish inside the car, PVC floor finish, and all other devices

complying to fire escape, emergency evacuation control, NBC

etc. complete in all respect inclusive of taxes duties etc.

EACH 2.00

7.4 Supply, installation testing and commissioning of lifts of

maximum rated load 544Kg, speed 1.00mps, travelleing for G

+ 7 floors of travel height hair line stainlesssteel venyle floor

finish, centre opening automatic door of fire retardent capacity

not less than 2hours with machine room, gear less system

inclusive of all accessories, gadgets, emergency light car

operating panel indicator door close and open button alarms,

colour LCD display, emergency phone, handicapped COP,

braille push buttons, star light ceiling finish inside the car, PVC

floor finish, and all other devices complying to fire escape,

emergency evacuation control, NBC etc. complete in all respect

inclusive of taxes duties etc.

EACH 1.00

1.7 LAB BLOCK LIFT PANEL each 1.00

1.8 APARTMENT BLOCK LIFT PANEL each 1.00

Internal Electrification (Part-A)

Page 79: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

1 Wiring for light point/ fan point/ exhaust fan point/ call bell

point with 1.5 sq.mm FRLS PVC insulated copper conductor

single core cable in surface / recessed medium class PVC

conduit, with modular switch, modular plate, suitable GI box

and earthing the point with 1.5 sq.mm FRLS PVC insulated

copper conductor single core cable etc. as required.

1.1 Group B Point 169.00

1.2 Group C Point 749.00

2 Wiring for circuit/ submain wiring alongwith earth wire with

the following sizes of FRLS PVC insulated copper conductor,

single core cable in surface/ recessed medium class PVC

conduit as required.2.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire meter 6,050.00

2.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire meter 10,265.00

2.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire meter 6,819.00

2.4 4 X 4 sq. mm + 2 X 4 sq. mm earth wire meter 250.00

3 Supplying and fixing of following sizes of medium class PVC

conduit along with accessories in surface/recess including

cutting the wall and making good the same in case of recessed

conduit as required. 3.1 25 mm meter 850.00

3.2 32 mm meter 550.00

4 Supplying and fixing following modular switch/ socket on the

existing modular plate & switch box including connections but

excluding modular plate etc. as required.

4.1 5/6 A switch Each 134.00

4.2 15/16 A switch Each 568.00

4.3 3 pin 5/6 A socket outlet Each 1,430.00

4.4 6 pin 15/16 A socket outlet Each 136.00

4.5 Bell push Each 24.00

5 Supplying and fixing two module stepped type electronic fan

regulator on the existing modular plate switch box including

connections but excluding modular plate etc. as required.

Each 78.00

6 Supplying and fixing modular blanking plate on the existing

modular plate & switch box excluding modular plate as

required.

Each 432.00

Page 80: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

7 Supplying and fixing following size/ modules, GI box alongwith

modular base & cover plate for modular switches in recess etc.

as required.

7.2 3 Module (100 mmX75 mm) Each 134.00

7.3 4 Module (125 mmX75 mm) Each 136.00

7.4 8 Module (125 mmX125 mm) Each 432.00

8 Supplying and fixing 3 pin, 5 A ceiling rose on the existing

junction box/ wooden block including connections etc. as

required.

Each 44.00

9 Wiring for group controlled (looped) light point/fan

point/exhaust fan point/ call bell point (without independent

switch etc.) with 1.5 sq. mm FRLS PVC insulated copper

conductor single core cable in surface/ recessed PVC conduit,

and earthing the point with 1.5 sq. mm FRLS PVC insulated

copper conductor single

core cable etc. as required.9.1 Group C Point 422.00

10 Supplying and fixing following way, single pole and neutral,

sheet steel, MCB distribution board, 240 V, on surface/ recess,

complete with tinned copper bus bar, neutral bus bar, earth

bar, din bar, interconnections, powder painted including

earthing etc. as required. (But without MCB/RCCB/Isolator)

10.1 6 way, Double door Each 32.00

11 Supplying and fixing following way, horizontal type three pole

and neutral, sheet steel, MCB distribution board, 415 V, on

surface/ recess, complete with tinned copper bus bar, neutral

bus bar, earth bar, din bar, interconnections, powder painted

including earthing etc. as required. (But without

MCB/RCCB/Isolator)11.1 4 way (4 + 12), Double door Each 32.00

11.2 6 way (4 + 18), Double door Each 17.00

13 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”

curve, miniature circuit breaker suitable for inductive load of

following poles in the existing MCB DB complete with

connections, testing and commissioning etc. as required.

13.1 Single pole Each 816.00

MCCB, MCB & DB’S

Page 81: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

13.2 Double pole Each 41.00

13.3 Triple pole and neutral Each 44.00

13.3 Supplying and fixing single pole blanking plate in the

existing MCB DB complete etc. as required.

Each 112.00

15 Supplying and fixing 30 A, 415 V, TPN Industrial type socket

outlet, with 4 pole and earth, metal enclosed plug top

alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on

surface or in recess, with chained metal cover for the socket

out let and complete with connections, testing and

commissioning etc. as

required.

Each 16.00

16 Supplying and installing following size of perforated Hot Dipped

Galvanised Iron cable tray (galvanisation thickness not less than

50 microns) with perforation not more than 17.5%, in

convenient sections, joined with connectors, suspended from

the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.

as required.16.1 150 mm width X 50 mm depth X 1.6 mm thickness Each 115.00

16.2 300 mm width X 50 mm depth X 1.6 mm thickness Each 640.00

17 Supplying and installing following size of perforated Hot Dipped

Galvanised Iron cable tray “bends” (galvanisation not less than

50 microns) with perforation not more than 17.5%, in

convenient sections, joined with connectors, suspended from

the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.

as required.17.1 150 mm width X 50 mm depth X 1.6 mm thickness Each 13.00

17.2 300 mm width X 50 mm depth X 1.6 mm thickness Each 36.00

18 Supplying and installing following size of perforated Hot Dipped

Galvanised Iron cable tray “Tee” (galvanisation not less than 50

microns) with perforation not more than 17.5%, in convenient

sections, joined with connectors, suspended from the ceiling

with G.I. suspenders including G.I. bolts & nuts, etc. as

required.18.1 150 mm width X 50 mm depth X 1.6 mm thickness Each 4.00

18.1 300 mm width X 50 mm depth X 1.6 mm thickness Each 8.00

Internal Electrification (Part-B)

Page 82: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

1.00 MV SWITCHGEAR / POWER PANEL / DISTRIBUTION BOARDS.

1.10 POWER PANEL:

Supply, installation, testing and commissioning of cubicle type

panels as specified and shown on drawing no. WTE2291/STAGE

2/7.001 SHEET 1

i) Main Aluminium busbars with bar type feeder connections &

all internal wiring and connections.

ii) Earthing all components, frame etc. to a common internal

earth bar.

iii) Powder Coat painting of all sheet metal works.

iv) All accessories & supporting structure.

v) Brass glands and crimping lugs for sending and receiving

ends.

vi) All ammeters with C.T's and voltmeter and energy meters

with necessary fuses.

vii) Panel components as specified.

viii) MS base frame.

ix) All switch gear to have short circuit levels as specified.

1.9 LAB BLOCK LIGHTING & POWR FLOOR PANEL (L1, L2, L3) each 2.00

1.10 APARTMENT BLOCK LIGHTING & POWR FLOOR PANEL A1 each 1.00

1.11 APARTMENT BLOCK LIGHTING & POWR FLOOR PANEL A2, A3 each 1.00

1.12 KITCHEN & DINNING DB each 1.00

1.13 LAB DB (1 TO 8) each 16.00

3.1 Supply & fixing of light fixtures complete with:

a) Lamps and Ballasts

b) all necessary accessories as required

C) all necessary Down rods & fixing accessories for suspending

type light fittings

3.1.1 600 x 600 mm recess mounting decorative direct/indirect LED luminaire enclosed in powder coated CRCA deep drawn housing with unique floating spherical direct diffuser and surrounding indirect light chamber. The luminaire comprised with two optical compertment and it should be controlled seperately. The maximum system wattage should be 34W with minimum system efficacy 100lm/w, CCT 5700K, CRI> 80. . Luminaire driver should be Isolated and multistage constant current constant voltage type. input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 3KV surge protection, PF >0.95, THD <10%, Similar to Wipro Make LM38-461-XXX-57-XX or Equivalent.each 96.00

3.1.2 Supply of recess mounted LED Downlight enclosed in preseure die cast aluminum housing for superior heat management and HET diffuser for better light output and uniform light distribution without glare. The maximum system wattage should be 11W with minimum system efficacy 95lm/w, CCT 6500K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2.5KV surge protection, PF >0.95, THD <20%, Similar to Wipro Make LD91-141-XXX-65-XX or equivalent.each 130.00

3.1.3 Supply of recess mounted LED Downlight enclosed in preseure die cast aluminum housing for superior heat management and HET diffuser for better light output and uniform light distribution without glare. The maximum system wattage should be 15W with minimum system efficacy 95lm/w, CCT 6500K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2.5KV surge protection, PF >0.95, THD <20%, Similar to Wipro Make LD91-201-XXX-65-XX or equivalent.each 422.00

Page 83: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

3.1.4 Surface mounted 600mm high effiecency 10W integrated LED

batten, with minimum 100 Lumens/Watt efficacy. CCT 6500K,

CRI> 80. Luminaire driver should be Isolated and multistage

constant current type. Driver Input voltage range of 150V to

270V ( nominal rated voltage – 240V) with minimum 2.5KV

surge protection, PF >0.90, THD <20%, Similar to Wipro Make

LL20-111-XXX-65-NE or equivalent.

each 75.00

3.1.5 Surface mounted 1200mm high effiecency 20W integrated LED batten, with minimum 100 Lumens/Watt efficacy. CCT 6500K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2.5KV surge protection, PF >0.90, THD <20%, Similar to Wipro Make LL20-221-XXX-65NE1 or equivalent.each 161.00

3.1.6 Surface/Suspended integrated LED Channel enclosed in CRCA housing for superior heat management and highly effective extruded Polycarbonate diffuser for maximum effective illumination. The maximum system wattage should be 39W with minimum system efficacy 100lm/w, CCT 5700K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 3KV surge protection, PF >0.95, THD <10%, Similar to Wipro Make LE10-491-XXX-57-XX or equivalent.each 176.00

3.1.7 Suspended circular decorative LED Luminaire enclosed in CRCA housing for superior heat management and highly effective PMMA diffuser for maximum effective illumination. The maximum system wattage should be 26W, CCT 5700K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 3KV surge protection, PF >0.95, THD <10%, Similar to Wipro Make LM71-341-XXX-57-XX or equivalent.each 23.00

3.1.8 Surface mounted LED Downlight enclosed in CRCA housing for superior heat management and HET diffuser for better light output and uniform light distribution. The maximum system wattage should be 9W. CCT 5700K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2.5KV surge protection, PF >0.9, THD <20%, Similar to Wipro Make LW01-101-XXX-57-XX or equivalent.each 39.00

3.1.9 Supply of Bulkhead LED enclosed in die cast Aluminium housing for superior heat management and Polycarbinate opul diffuser. The maximum system wattage should be 10W. CCT 5700K, CRI> 80. Luminaire driver should be Isolated and multistage constant current type. Driver Input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2.5KV surge protection, PF >0.9, THD <20%,. Luminaire should be IP65 Protected. Similar to Wipro Make LW07-141-XXX-57-XX or equivalent.each 43.00

3.1.10 Supply of 2W recessed mounted LED Footlamp with all mounting accsessories. Similar To Wipro Make FL921or equivalent.each 24.00

3.1.12 300mm sweep exhaust fan each 46.00

3.1.13 BUZZER each 24.00

3.1.14 1200 mm sweep ceiling Fan each 64.00

3.1.15 600 mm sweep hi- speed ceiling Fan each 14.00

3.1.16 KEY card switch 3 PHASE each 8.00

3.1.17 KEY card switch single PHASE each 16.00

8 LAN SYSTEM

LAN NETWORK SYSTEM

Page 84: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

8.1 PoE+ 24 Port Switch

The switch should have 24 x 10/100/1000Base t ports plus 4x

1000x SFP ports .Min 370 Watt PoE power budget and support

for IEEE 802.3af and IEEE 802.3at, Switch should have 16K MAC

entries table.Should have 8 Hardware QOS Queues per port ,OS

should support individual process (eg ssh , snmp, telnet, dhcp

etc) restart to prevent reboot in case of Software Process Crash

by running processes on top of Kernel.Switch should have

switching fabric performance of minimum 56Gbps switch

fabric. Layer 2, IP v4 & IP v6 - Switch should be upgradeable to

Open Shortest Path First (OSPF) and VRRP.Should support less

than 50 Millisecond convergance for ring based architecture

based on RFC 3619/REP/ERPS/G.8032 etc, Switch should have

Port, vlan, IPv4, IPv6, and time based Access Control Lists for

both directions. Switch should have Operating temperature:

32 to 122°F (0°C to 45°C). Preffered Make : CISCO/Extreme

/Juniper /Avaya

NOS 21.00

8.2 Core Switch

Switch should support stacking up to 8 switches or more with

stacking bandwidth of 40Gbps . The switch should have24x

10/100/1000Base t ports with 8x 1000x SFP ports .Min 4 10 G

based SFP+ port , Scalable to min 2 QSFP+ port , The switch

should be upgraded to 4 x SFP+ ports in future without

changing the base hardware . Should have min 2x Stacking port

with min 40 Gbps stacking bandwidth from day 1 .Stacking

should be ready from day 1 with accessorries /cables.Stacking

mechanism could be achieved over a diversified location as

minimum 800 Meters . Switch should have dedicated 1 x

10/100/1000 BaseT port for Out of band Management port.

Switch should have Operating temperature: 32 to 122°F

(0°C to 50°C). Preffered Make : CISCO/Extreme /Juniper /Avaya

NOS 1.00

8.3 CAT6 UTP cable - 4 pairs PVC - 23 AWG - 305 mtr Box4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable 305 mtr per Box. Blue/Orange/White/Green in colour conforming to the following standards like 23AWG, ANSI EIA/TIA 568 C.2, EN50173, IEC 11801 3rd ED, frequency tested upto 700Mhz with Third Party Certificate etc. Cable Dia 6.1 ± 0.3, Cross-member (+) fluted Spine/isolator for uniform separation for all pairs. (Make : Legrand /Systemax/Hubbel)Box 46.00

8.4 CAT6 RJ45 socket - User EndCat 6 UTP RJ 45 Sockets Tool Less Crimping, as per - ISO/IEC 11801 Edition 2; ANSI/EIA/TIA 568-C.2; IEC series 60603-7, should have transparent shutter for protection against dust, Contacts :gold/nickel, minimum thickness of gold > 0.8 μm , Body should PBT Polycarbonate plastic material, IEEE 802.3af standard and PoE+, Endurance 2500 movements (plug insertion/withdrawal). IK03. Operating Temp -40 Deg C to +70 Deg C, Maximum no of Connections/ Re connections 5 without refreshing the wiring. (Make : Legrand /Systemax/Hubbel)Nos 325.00

Page 85: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

8.5 CAT6 UTP patch panel - 24 port loaded - Toolless

CAT6 UTP RJ45 Loaded patch panel & connector - 24 port

loaded 19" panel - 1 U, Panel: DC01 galvanised sheet steel,

Compliant with standards: ISO/IEC 11801 Edition 3.0 CENELEC

EN 50173-1 2007 ANSI/EIA/TIA 568 C2-1 IEC series 60603-7,

NFC 20730, Standard 8877 – 603.7, Contacts: gold/nickel,

thickness of gold > 0.8 μm minimum, Equipped with rear cable

guide to hold cable during maintenance,The connectors are

connected from the front without a special tool. Equipped with

4 cassettes of 6 RJ45 Cat. 6 connectors with toolless fast

connection, marked 568 A/B, Max. number of connections and

disconnections: 5 without replacing the wire, Endurance: 2500

operations (plug-in/pull-out) IK03, Operating temperature: -

40°C to +70°C (Make : Legrand /Systemax/Hubbel)

Nos 15.00

8.6 CAT6 UTP patch cord - 1 mtr - Rack End

1 Meter Cat 6 U/ UTP Patch Cord, PVC,Performance at 250MHz

Should be as per Standards - IEC 61935-2 - Ed. 3.0 ISO/IEC

11801, Usage Temp – 20 to + 60°C, No of Twists 500, No of

insertions 750, 24 AWG (Make : Legrand /Systemax/Hubbel)

Nos 325.00

8.7 CAT6 UTP patch cord - 2 mtr - User End

2 Meter Cat 6 U/ UTP Patch Cord, PVC ,Performance at

250MHz Should be as per Standards - IEC 61935-2 - Ed. 3.0

ISO/IEC 11801, Usage Temp – 20 to + 60°C, No of Twists 500,

No of insertions 750, 24 AWG (Make : Legrand

/Systemax/Hubbel)

Nos 325.00

8.8 Single port face plate

Single Port Face Plate 1 Module in white colour. (Make :

Legrand /Systemax/Hubbel)

Nos 325.00

8.9 Plastic surface box - 1/2 module

Plastic Flush Mounting Box 1/2 Module. (Make : Legrand

/Systemax/Hubbel)

Mtr 325.00

Page 86: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

9.0 6 Core OM3 Unarmoured LSZH OFC

6 Core - Optic fiber cable OM3 - Unitube Single Jacket Unarmor

Lite, Jelly Filled Loose Tube Optical Fiber Cable 50 μm /125

μm , Glass Roving Yarn provide tensile strength and

antibuckling properties. LSZH Aqua RAL-6027, IEC 60793-2-10

category A1a.2; EN 60793-2-10: type A1a.2, TIA/EIA-492 AAAB,

ITU Recommendation G.651, EN 50 173:2002 category

OM3,ISO/IEC 11801:2002 category OM3, IEEE 802.3-2002 incl.

amendment 802.3ae - 2002. Maximum installation tensile

strength - E1 1000 N, - Short term tensilestrength - E1 650 N, -

Permanent tensilestrength - E1 350 N , Compressive

strength(crush) - E3 1500 N, Min. Bending radius,unloaded -

E11 10 D, Min. Bending radius,loaded 20 D, Operating temp : -

30°C to +70°C (Make : Legrand /Systemax/Hubbel)

Nos 400.00

9.1 19" Modular optic drawer

6 to 96 Port Rack mount Sliding Fibre optic drawer (LIU) with

trasperent cover, Metal 19” fibre optic drawers, 4 cable entries,

supplied with screw fixing kit, 2 cable glands (Ø 13.5 and 16

mm), coiling system, Sliding: end stop at a 30° angle for easier

wiring with lock with lock. Depth: 220 mm, height 1 U (Make :

Legrand /Systemax/Hubbel)

Nos 3.00

9.2 SC pigtails - OM3 - 1 mtr

SC pigtails - OM3 - 1 mtr, ITU-G651, standards TIA / EIA

492AAAD , 900 μm tight structure, Crush Resistance 500N

Operating temp : - 20°C to +60°C (Make : Legrand

/Systemax/Hubbel)

Nos 54.00

9.3 Unit of 3 duplex SC adapters loaded with adapter plate - MM

6 port Adapter plate, loaded with 3 nos. of duplex SC unit for

multi mode fiber adapters to be compatible to fit in 19" U/UTP

24 port modular patch panel or 24 port LIU. (Make : Legrand

/Systemax/Hubbel)

Nos 9.00

9.4 Splice Tray - 24 fibre capacity

Stackable Splice Tray - 24 fibre capacity, Stack upto 2 Splice

Tray In Single LIU (Make : Legrand /Systemax/Hubbel)

Nos 3.00

Page 87: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

9.5 Blanking plate for LIU

Blanking plate for LIU and Modular Patch Panel (6XRJ45

Blanking plate for 19" panel - Black in colour). (Make : Legrand

/Systemax/Hubbel)

Nos 4.00

9.6 SC/LC duplex fibre patch cord - OM3 - 3 mtr

3 Meter SC/LC Optic Fiber Patch Cords – Multimode (OM3)

Operating temp : - 20°C to +60°C. Insertion loss: 0.15dB, 500

matings. Conform to IEC, EIA-TIA, and Telecordia performances

requirements. (Make : Legrand /Systemax/Hubbel)

Nos 9.00

9.7 Racks : 42U 800x800 Free standing cabinet with all standard accessoriesWidth (mm) 800, Depth (mm) 800, Approx.Net Wt (kg) 150, CRCA 'D' Grade thickness (mm) 1.2, RAL 9017 (Matt Black), Glass: 4mm Toughened Tinted Glass Door, Injected one piece polyurethane gasket on frame, Accessories: Cooling Fan (230V A/C 90 CFM) - 4 Nos, Cable Manager Metal- 4 Nos, PDU 230VAC - 1 No (12 nos. 6A/16A sockets with plugs 6A/16A - 1/1pc & MCB 16A/32A - 0/1 Pc), Cable Channel 100mm wide 42U- 2 Nos, Heavy Duty Stationary Shelf 600W x 475D - 1 No., Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) - 3 Nos., Earthing Strips 150mm H - 1 No, Door Lock - 1 No, Castor Wheels (with Brake) - 2 Nos, Castor Wheels (without Brake) - 2 Nos, Front Metal Band - 1 No. Packing: 5 ply cardboard & Inside 28 ply EP foam. In the rack there must be maintained 1 U = 1.75 inches space. ( Make :Legrand/ Rittal / Valrack)Nos 1.00

9.8 27U 800x800 Free standing cabinet with all standard accessoriesWidth (mm)-800, Depth (mm) - 800, Approx.Net Wt (kg) - 100, CRCA 'D' Grade thickness (mm) - 1.2, RAL 9017 (Matt Black), Glass - 4mm Toughened Tinted Glass Door, Accessories:, Cooling Fan (230V A/C 90 CFM) - 4 Nos, PDU 230V AC - 1, Cable Channel 100mm wide 22U - 2 No, Cable Manager Metal - 2 Nos, Heavy Duty Stationary Shelf 600W x 475D - 1 No., Earthing Strips 150mm H - 1 No, Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) - 3 No, Door Lock - 1 No, Front Metal Band -1 No., Castor Wheels (with Brake) - 2 Nos., Castor Wheels (without Brake) - 2 Nos. Packing: 5 ply cardboard & Inside 28 ply EP foam. In the rack there must be maintained1 U = 1.75 inches space. Nos 2.00

11.0 RISING MAIN

11.1 Supplying, installing on wall, testing and commissioning of

following capacity 1000 volt grade, 3phase 4 wire ( 100% N), IP-

55 Sandwich Type Rising mains made of 1.5 mm thick Hot-

galvanized sheet Steel confirming IK-10 impact strength duly

painted with RAL 7035 Resin , wall straps, fully insulated by

Class F ( 155 deg ) PET Film 4 Nos aluminium bus bars ( Cu+ Tin

Plating) in convenient sections and suitable for 415 volts, 3

phase, 4 wire, 50 Hz, A.C. supply with factory fitted joint

monobloc, expansion joints ( if length more than 40 mtrs), joint

cover, End Cover, Spring brackets and earthing with 2 runs of

Aluminium Earth strips etc. and provision for 2 nos. tap-off box

in each floor as required. (Rising mains confirming to IS 8623,

IEC 61439- 6, DIN VDE 0660 PART 500 AND 502)

11.1.1 1600 amps (S.C. rating for 1 sec - 50 KA) meter 22.50

11.1.2 630 amps (S.C. rating for 1 sec - 50 KA) meter 13.50

11.1.3 Elbow ( fabrication Cost) for 1600A NOS 4.00

11.1.4 Elbow ( fabrication Cost) for 630A NOS 4.00

11.1.5 Flanged End (fabrication Cost) for 1600A NOS 2.00

11.1.6 Flanged End (fabrication Cost) for 630A NOS 1.00

11.1.7 1600A Braided Cu Flexible ( electro-tinned with silver coated Socket) TPNSETS 2.00

11.1.8 630A Braided Cu Flexible ( electro-tinned with silver coated Socket) TPNSETS 1.00

11.1.9 Adopter Box for 1600A/ 630A NOS 3.00

Page 88: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

12.0 Supplying, installing, testing and commissioning of following

capacity 4P tap off box / plug-in box made of 1.5mm thick

sheet steel enclosure duly painted with powder coating on

existing bus bar system complete with 4P MCCB, 36KA T/M

release , connection, earthing etc. as follows.

12.1 Tap-off-Box with 250A, FP, ( I cs = Icu = 36kA ) , incomer MCCB each 4.00

12.2 Tap-off-Box with 100A, FP, ( I cs = Icu = 36kA ) , incomer MCCB each 2.00

13.0 Supplying and fixing following modular switch / socket on the

modular plate & switch box including connections modular

plate etc. as required.

13.1 20 amps switch WITH 6 pin 20 amp socket outlet each 32.00

14.0 Supply, installation, testing & commissioning of 20 kva true

online double conversion UPS system with 30 mins & with

inbuilt isolation Transformer, SMF battery backup, MS rack

Links and accessories as required

each 2.00

C Providing and fixing following capacity 4 pole automatic on

load ON/OFF -Load changeover switches with side handle

operation, in sheet enclosure in metal board including drilling

holes in metal board, making connection , earthing the body

etc. as required.16.1 100 A , 4 POLE nos 1.00

17.0 supply, laying, testing, commissioning, of under floor GI race

ways with all accsesaries of following dimention DLP

TRUNKING

17.1 PLASTIC TRUNKING 105MMX50MMX 2MTR EACH 175.00

17.2 FLEXIBLE COVER 85MM WIDTH EACH 118.00

17.3 4 MOSAIC MOD.FRA FOR 85MM COVE EACH 128.00

17.4 JOINT FOR 85MM WIDTH COVER EACH 352.00

17.5 BASE JOINT EACH 352.00

17.6 END CAP EACH 64.00

17.7 INTERNAL ANGLES-ADJ FRM 80 DEG EACH 448.00

17.8 EXTERNAL ANGLES-ADJ FRM 60 DEG EACH 448.00

17.9 FLAT ANGLES EACH 224.00

17.10 SOCKET SHUTTERED 6/16 3 PIN INDIAN 3 MODULE EACH 128.00

17.11 SWITCH 20 A SP 1 WAY 1 MODULE EACH 128.00

Page 89: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

18.0 supply, laying, testing, commissioning, of under floor GI race

ways with all accsesaries of following dimention

18.1 225mmx38 mm 3 compartments race way (2.44 mtr) EACH 200.00

18.2 GI FIXING BRACKET 225X25 MM (1 No. for 2mtr) EACH 208.00

18.3 COUPLING 38 (For joining 2 pieces of raceway) EACH 100.00

18.4 225x225 mm height adjustable junction box 50-70mm EACH 160.00

Total of Part-E

Page 90: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Item no. Description Unit Quantity Rate in figure (Rs.) Rate in words Amount (Rs.)

Sub Head-A

1 Laying and fixing of one number PVC insulated and PVC

sheathed / XLPE power cable of 1.1 kV grade of following

size on cable tray as required.

1.1 Upto 35 sq. mm (clamped with 1mm thick saddle) meter 1566.00

1.2 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/

40x3mm MS flat clamp)

meter 120.00

1.3 Above 185 sq. mm and upto 400 sq. mm (clamped with

40x3mm MS flat clamp)

meter 160.00

2 Supplying and making end termination with brass

compression gland and aluminium lugs for following size

of PVC insulated and PVC sheathed / XLPE aluminium

conductor cable of 1.1 kV grade as required.

2.1 3½ X 35 sq. mm (32mm) each 8.00

2.2 3½ X 185 sq. mm (57mm) each 2.00

2.3 3½ X 300 sq. mm (70 mm) each 6.00

2.4 4 X 10 sq. mm (25 mm) each 10.00

2.5 4 X 16 sq. mm (28mm) each 30.00

3 Supplying and installing following size of perforated Hot

Dipped Galvanised Iron cable tray (galvanisation thickness

not less than 50 microns) with perforation not more than

17.5%, in convenient sections, joined with connectors,

suspended from the ceiling with G.I. suspenders including

G.I. bolts & nuts, etc. as required.

3.1 150 mm width X 50 mm depth X 1.6 mm thickness Each 150.00

3.2 300 mm width X 50 mm depth X 1.6 mm thickness Each 110.00

Bill of Quantity

Name of Work: Construction of Research Park at IITG Campus.

Part-F(HVAC works)

CHAPTER 7-MV CABLE LAYING

CHAPTER 9-MV CABLE JOINTING & END TERMINATION

CHAPTER-4-CABLE TRAYS

Page 91: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

4 Supplying and installing following size of perforated Hot

Dipped Galvanised Iron cable tray “bends” (galvanisation

not less than 50 microns) with perforation not more than

17.5%, in convenient sections, joined with connectors,

suspended from the ceiling with G.I. suspenders including

G.I. bolts & nuts, etc. as required.

4.1 150 mm width X 50 mm depth X 1.6 mm thickness Each 6.00

4.2 300 mm width X 50 mm depth X 1.6 mm thickness Each 6.00

5 Supplying and installing following size of perforated Hot

Dipped Galvanised Iron cable tray “Tee” (galvanisation

not less than 50 microns) with perforation not more than

17.5%, in convenient sections, joined with connectors,

suspended from the ceiling with G.I. suspenders including

G.I. bolts & nuts, etc. as required.

5.1 150 mm width X 50 mm depth X 1.6 mm thickness Each 6.00

5.2 300 mm width X 50 mm depth X 1.6 mm thickness Each 6.00

6.1 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia

including accessories, and providing masonry enclosure

with cover plate having locking arrangement and

watering pipe etc. with charcoal/coke and salt as

required.

Each 4.00

6.2 Supplying and laying 25 mm X 5 mm G.I strip at 0.50

meter below ground as strip earth electrode, including

connection/terminating with G.I. nut, bolt, spring, washer

etc. as required.(Jointing shall be done by overlapping

and with 2 sets of G.I. nut bolt & spring washer spaced at

50 mm)

meter 40.00

6.3 Providing and fixing 25 mm X 5 mm G.I. strip on surface or

in recess for connections etc. as required.

meter 20.00

6.4 Providing and fixing 6 SWG dia G.I. wire on surface or in

recess for loop earthing as required.

meter 80.00

Sub Head-B

VRF Airconditioning system

VRF/ VRV -IVth generation Outdoor units

CHAPTER-5-EARTHING

Page 92: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

1.0 Supply Installation Testing & commissioning of IVth

Generation air cooled Full Inverter VRF System with

Modular type outdoor units, all scroll DC Inverter

compressors for cooling & Heating applications along

with different types of indoors compitable with VRF

ODUs. All inverter capacity controlling compressors shall

be suitable for 3 Phase, 50 Hz.. The outdoor should be

with 'Ocean Black Fin' heat exchanger with a black

coating to shield it from Salt, Sand & other elements

brought in by the air. The manufacturer must be having

its own make compressor fitted in outdoor.   All proposed

outdoor unit should have minimum COP of 4.0 & 6.1 at

100% & 50% load condition respectively for Cooling

.conditions ((Outside DBT-35 Deg C & Inside DBT 27 Deg C

&19 WBT) .COP should be based on nominal capacity as

mentioned in BOQ and power input at this condition i/c

first charge of refrigenet .Refrigerent shall be used 410a.

1.1 8 HP (22.4 KW) Top discharge Nos 4

1.2 10 HP (28 KW) Top discharge Nos 1

1.3 12 HP (33.6 KW) Top discharge Nos 4

1.4 20 HP (56 KW) Top discharge Nos 11

2.0 VRF/ VRV -Indoor units.

Supply, Instalaltion, testing and commissioning of(

histatcic ductable Type/Casseette Type/Hiwall Type)

Indoor units equipped with pre-filter, fan section with

suitable static fan, multispeed motor, coil section with

DX coil, outer cabinet, insulation, pipe connections etc.

of various capacities as per specifications and drawings.

The minimum TR/CFM has to be adhere while selecting

the equipment.Diversity beetwen ODU and IDU should

not exceed 108 %. Vendor has to select IDU or ODU of

nearby higher capacity to maintain the diversity as

specified.

2.1 Hi Static Type

2.1.1 8 TR/2650 CFM Nos 2

2.2 Cassette Type indoors

Page 93: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

2.2.1 4 TR/1200 CFM Nos 2

2.2.2 2.5 TR/940 CFM Nos 22

2.2.3 3.5 TR /1164 CFM Nos 36

2.3 Hiwall Type

2.3.1 1.28 TR /470 CFM Nos 32

3.00 TFA

3.10 Supply , Installation , Testing & commissioining of Fresh

Air unit with low noise BLDC motor .It can supply the

fresh air in conditioned space and create positive presure

inside which can reduce contaminated air from outside.

3.1.1 6.3 TR/835 CFM Nos 4

4.00 SITC of Refnet joints for proper distribution of refrigernt

through the complete circuit for indoor and Outdoor

4.1 Refnet Nos 98

4.2 SITC ofCorded remote controller-For Cassette & Hi Static Nos 6

4.3 SITC of Cordless Remote Controller- For Hi wall Nos 92

5.00 Supply , Installation , Testing & commissioining of

interconnecting refrigerant piping along with closed cell

elastomeric insulation and supports, between indoor &

outdoor units duly insulated as per specifications. Make-

Rajco/Mandev5.1 41.3 mm O.D. ( insulation : 19 mm ) RM 160

5.2 34.9 mm O.D. ( insulation : 19 mm ) RM 210

5.3 28.6 mm O.D. ( insulation : 19 mm ) RM 340

5.4 25.4 mm O.D. ( insulation : 19 mm ) RM 180

5.5 22.2 mm O.D. ( insulation : 19 mm ) RM 240

5.6 19.1 mm O.D. ( insulation : 13 mm ) RM 350

5.7 15.9 mm O.D. ( insulation : 13 mm ) RM 650

5.8 12.7 mm O.D. ( insulation : 13 mm ) RM 220

5.9 9.5 mm O.D. ( insulation : 13 mm ) RM 590

5.10 6.4 mm O.D. ( insulation : 13 mm ) RM 180

6.00 SITC of 1.5 sq x 2c mm shielded cu cable for

communication

RM 2200

Page 94: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

7.00 Supply, installation, testing and balancing of powder

coated Extruded Aluminium supply air Grilles with volume

control dampers in accordance with the approved shop

drawings and specifications.Make-Dynacraft/Sysytem Air

Sq Mt 12

8.00 Supply, installation, testing and balancing of Air Grilles

without volume control dampers in accordance with the

approved shop drawings and specifications.Make-

Dynacraft/Sysytem Air

Sq Mt 8

9.00 Supply, installation, testing and balancing of powder

coated Extruded Aluminium supply air Diffuse with

volume control dampers in accordance with the approved

shop drawings and specifications.Make-

Dynacraft/Sysytem Air/

Sq Mt 10

10.00 Supply, installation, testing and balancing of Air Diffuse

without volume control dampers in accordance with the

approved shop drawings and specifications.Make-

Dynacraft/Sysytem Air/

Sq Mt 10

11.00 Supply, installation and testing of Factory fabricated GI

sheet metal ducts as per approved shop drawings and as

required by the specifications with 6 mm nitrile insulation

. Make-Jindal/Tata11.1 22 G Sq Mt 150

11.2 24 G Sq Mt 350

12.00 Supply, fabrication, installation and testing the flexible

connections constructed of fire resistance flexible double

canvas sleeve as per the approved shop drawings.

Nos 2

13.00 DRAIN PIPING : Supply, Installation and Testing of UPVC

heavy class drain piping insulated out of 13 mm thick

Class O closed cell elastomeric nitrile rubber material of

approved make as per specification complete with

supports, consumables, fittings, pipe sleeves, U trap &

leak arresting of following sizes.

13.1 25 mm RMT 450

13.2 32 mm RMT 350

13.3 40 mm RMT 180

14.0 POWER PANEL:

Page 95: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

Supply, installation, testing and commissioning of cubicle

type panels as specified and shown on drawing no.

WTE2291/STAGE 2/7.001 SHEET 1

i) Main Aluminium busbars with bar type feeder

connections & all internal wiring and connections.

ii) Earthing all components, frame etc. to a common

internal earth bar.

iii) Powder Coat painting of all sheet metal works.

iv) All accessories & supporting structure.

v) Brass glands and crimping lugs for sending and

receiving ends.

vi) All ammeters with C.T's and voltmeter and energy

meters with necessary fuses.

vii) Panel components as specified.

viii) MS base frame.

ix) All switch gear to have short circuit levels as specified.

14.1 LAB BLOCK MAIN AC PANEL NOS 1

i) 1 Nos.1000A, 4P, EDO, microprocessor based

ACB complete with Over current & S/C protection as

incomer

ii) 2 Nos. 200A TPN MCCB complete with Over

current & S/C protection as OUTGOING

iii) 6 Nos. 160A TPN MCCB complete with Over

current & S/C protection as OUTGOING

iv) 3 Nos. 63A TPN MCB complete with Over current

& S/C protection as OUTGOING

v) 96 mm² Voltmeter 0 - 600V with Voltmeter

selector switch - 3Nos

vi) 96 mm² Ampmeter 0-1000A with Ampmeter

selector switch - 3Nos.

vii) 3 Nos. CT's 1000/5A 10VA Class-I accuracy

viii) 3 Nos. indicating lamps (LED Type)

ix) TPN Aluminium busbar mounted on non-

hygroscopic insulator supports - 5x150x10 mm

electrical grade bar for phase 3x150x10 mm

electrical grade bar for neutral

x) Two Nos. 10 mm stud type earth terminals G.I.

earth bus bar arrangement

Page 96: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

14.2 APPARTMENT BLOCK MAIN AC PANEL NOS 1

i) 1 No.250A 4P MCCB complete with Over current

& S/C protection as incomer

ii) 2Nos. 63A TPN MCB as outgoing

iii) 16Nos. 32A TPN MCB as outgoing

iv) 96 mm² Voltmeter 0 - 600V with Voltmeter

selector switch - 1 No

v) 96 mm² Ampmeter 0-250A with Ampmeter

selector switch - 1No

vi) 3 Nos. CT's 250/5A 10VA Class-I accuracy

vii) 3 Nos. indicating lamps (LED Type)

viii) TPN Aluminium busbar mounted on non-

hygroscopic insulator supports - 1x100x6 mm

electrical grade bar for phase 1x80x6 mm electrical

grade bar for neutral

ix) Two Nos. 10 mm stud type earth terminals G.I.

earth bus bar arrangement

14.3 LAB BLOCK FLOOR AC PANEL NOS 2

i) 1 No.160A 4P MCCB complete with Over current

& S/C protection as incomer

ii) 6Nos. 63A TPN MCB as outgoing

iii) 3Nos. 32A TPN MCB as outgoing

iv) 3Nos. 20A DP MCB as outgoing

v) 96 mm² Voltmeter 0 - 600V with Voltmeter

selector switch - 1 No

vI) 96 mm² Ampmeter 0-250A with Ampmeter

selector switch - 1No

vii) 3 Nos. CT's 250/5A 10VA Class-I accuracy

viii) 3 Nos. indicating lamps (LED Type)

ix) TPN Aluminium busbar mounted on non-

hygroscopic insulator supports - 1x100x6 mm

electrical grade bar for phase 1x80x6 mm electrical

grade bar for neutral

x) Two Nos. 10 mm stud type earth terminals G.I.

earth bus bar arrangement

15.00 MV CABLE

15.1 Supply of heavy duty 1100V grade LT XLPE insulated

sheathed & armoured cables with aluminium / copper

conductors as specified and required.

15.1.1 4C X 10sq.mm. Al. Ar. XLPE Cable RM 330

Page 97: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

15.1.2 4C X 16sq.mm. Al. Ar. XLPE Cable RM 1164

15.1.3 3.5C X 35sq.mm. Al. Ar. XLPE Cable RM 72

15.1.4 3.5C X 185sq.mm. Al. Ar. XLPE Cable RM 120

15.1.5 3.5C X 300sq.mm. Al. Ar. XLPE Cable RM 160

16.0 Supply, installation, testing & commissioning of modular

type 240V, 50Hz, 25A stater with 20 A plug point

including base plate and necessary connection in

modular type MS box for 2TR, 1.5TR & 1TR split type AC

machine.

EACH 137

1 VENTILATION

1.1 Supply, erection, testing & commissioning of long casing

GSS Vane Axial (motor should complete accomodated in

side the fan casing) Flow Exhaust Fans (Fire Rated)of

capacity as below with TEFC single speed motor to suit

250 deg C for 2 hours.Fan should be complete with back

draft damper, outet wire guard, fan support frame work

in standard MS construction with painting. Fan should be

AMCA certified. Sound pressure level of the fan should

not exceed 73 dB(A) at 3 meter in room condition at given

CFM.

In case of vane axial, vanes outside of fan casing is not

acceptable.

1.1.1 EXHAUST FAN:AXIAL FLOW FAN: 3100 CFM @ 35 mm wg

static pressure for Kitchen, (SISW belt driven fan)

Nos 1

1.1.2 FRESH AIR SUPPLY FAN:AXIAL FLOW FAN: 3100 CFM @ 35

mm wg static pressure for Kitchen, (Vane Axial type direct

driven fan)

Nos 1

2 Supply, erection, testing & commissioning of rectangular

type direct driven inline fan. Fan should be AMCA

certified. Sound pressure level of the fan should not

exceed 55 dB(A) at 3 meter in room condition at given

CFM.2.1 750 CFM inline Fan for exhaust Nos 3

2.2 700 CFM inline Fan for exhaust Nos 3

3 DUCTING & ACCESSORIES

Page 98: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

3.1 Supply and installation of sheet metal ducting complete

with GI threaded supports, vanes, splitters, gaskets for

joints, thermal isolation blocks, etc. as per specs. 120

GSM sheets GI Sheet Metal Ducting (Rectangular) Factory

Fabricated (made on lock forming machine RTV sealed)

3.1.1 24 Gauge Sqm 310

3.1.2 22 gauge Sqm 80

4 EXHAUST AIR DIFFUSERS

4.1 Supply, installation ,testing and balancing of rectangular

square type air Grilles / Diffusers with volume control

dampers. Each diffuser shall be equipped with fixed air

distribution grid, removable core for proper balancing of

air distribution system Powder coated extruded

aluminium diffusers of approved colour suitable for

installation in ceiling with sizes.

Sqm 20

5 SUPPLY AIR DIFFUSERS

5.1 Supply, installation ,testing and balancing of rectangular

square type air Grilles / Diffusers with volume control

dampers. Each diffuser shall be equipped with fixed air

distribution grid, removable core for proper balancing of

air distribution system Powder coated extruded

aluminium diffusers of approved colour suitable for

installation in ceiling with sizes.

Sqm 10

6 GRAVITY LOUVER WITH BIRD SCREEN

6.1 Gravity louvershall be designed to maintained 3.0 mm

over pressure inside the room. Frame and louver (self

acting type) thickness shall be 1.25 mm & 0.63 mm

respectively. Constructional feature of frame & louver

shall G.I. & aluminum respectively. Size : As per the

dimension of discharge section of fan

No. 8

7 DUCT DAMPER

8 Duct damper shall be fabricated from G.I. sheet with MS

Frame. Frame & louver thickness shall be 1.6 mm & 1.0

mm respectively. Damper shall have suitable operating

lever with bush / bearing and low leakage.

Sqm 10

9 Lifting and shifting charges Lot 1

Page 99: COST ABSTRACT Name of Work: Construction of Research Park ... · (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated

10 Specialised structural works required for ventilation

system

Kg 100

Total of Part-F