22
COT Oil Refiner® System “e ultimate system to minimize presence of water and air in operating oils” COT AB Box 115 SE-341 22 Ljungby Sweden Tel: +46 733 83 71 18 E-mail: [email protected] www.cot.se

COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner® System“The ultimate system to minimize presence of water and air in operating oils”

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 2: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner® System

COT Oil Refiner® System, with its main component COT Oil Refiner® helps eliminate the growing problem with mixed-in water and air in machine oils, such as hydraulic oil, lubricating oil, transmis-sion oil, and more.

Known to most service and maintenance personnel, water- and air intrusion into machine oils will seriously damage and cause wear and tear on different propulsion systems. A machine’s downtime and damaged machine parts can often be related to water contamination. Water and air contamination in the oil is inevitable and when the occurrence reaches a certain level, harmful wear occurs on all parts of the system. By consistently reducing water content in the oil, you extend the life of components and gain a significant cost savings.

Desirable Objectives for a Hydraulic Unit:• Reducing unplanned downtime• Reducing the need for oil filter replacement• Avoiding wear and tear on moving parts• Minimizing corrosion• Minimizing the need for oil filter replacement due to accumulated water

COT Oil Refiner® System – with an additional vacuum pump - remove intrusive water and air from:

• Hydraulic Oil• Lubricating oil• Transformer oil• Gearbox oil

Advantages:• Removes all occurrence of free water and significantly reduces the level of

bound water to low PPM levels continuously• Enables conversion to synthetic oil• Reduces cost for maintenance• Easy to install• Low operating costs• Increases lifespan of hydraulic components• Extends lifespan on oils

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 3: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner® is the key component in COT Oil Refiner® System. With its patented point-heating method, water molecules are released from the oil without the risk of oil oxidation. The system signifi-cantly reduces the oil’s water content and by setting up your oil system by choosing additional compo-nents, almost every oil system can use the COT Oil Refiner®.

COT Oil Refiner® ”Keeps your oil free from intrusive water”

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

By a determined oil flow passing the COT Oil Refiner point-heated plate in combination with directed air streams, conditions are created to optimize evaporation of harmful liquid molecules.

Principle

Page 4: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

The Principle is that the oil flows through COT’s Oil Refiner® and is collected in the catch tank. The catch tank’s oil level is controlled by an oil level switch. When a certain oil level is reached, an electric pump pumps the oil out of the catch tank and back to the main oil system. If a malfunction occurs, e.g. due to lost power, a safety valve will shut down the Oil Refiner to prevent oil overflow. The catch tank can be customized according to the customer’s equipment.I: Catchtank mounted in a cabinet (stationary installations)II: Flexible installation based on space (mobile installations)

Catch Tank SizeRecommended Catch Tank size is 1-4 liters (1/4 – 1 US gal.)

Advantages of installing COT Catch Tank• No modification of the main hydraulic tank. COT’s Oil Refiner’s returning oil can be connected

directly to the main oil system.• Flexible installation enables the possibility to install the Catch Tank optimized depending on the

existing equipment.• By adding the vacuum option, mixed-in air in the oil can be removed.

II

II II

I

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

COT Catchtank System

Page 5: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Hydraulic tank installation COT Catchtank installation

This installation is recommended when the operating oil temperature of the main oil system ranges between 50-60°C (120-140°F) and the risk of water intrusion is moderate.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

COT Oil Refiner® - single

Page 6: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

This installation is recommended when the operating oil temperature of the main oil system normally stays below 50°C (120°F).

COT Oil Refiner® with Preheater and Pump

This installation is recommended for continuous operation and when the main oil system’s temperatu-re is normally below 50°C (120°F) and when the probability of extensive temporary water intrusion is high. In addition, this configuration is also suitable for system requiring improved particle filtration.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

COT Oil Refiner® with Preheater

Page 7: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Capacity and Performance

Capacity: The amount of water COT Oil Refiner® System can remove depends on several parameters like oil temperature, oil flow, and the ambient air humidity. To ensure optimal function of COT Oil Re-finer® System, these parameters must be considered and optimized. On average, the removing capacity is approximately 5ml per hour (0,3 fl. Oz).

50

40

30

20

10

0

60

70

80

90

100

Open airstreamsClosed airstreamsCompressed airCompressed air <10 RhVacuum pump

Air �ows: Di� comparisonsOil: Bio oilAdded water: ca 20 ml water, 100 RhTemp. oil in: 55 °C/130 °FTank size: 10 l

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Hours

Percent

PPM-value 200-250

Performance Test Rig Relative Humidity(Result may vary with different oils)

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 8: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Components COT Oil Refiner® SystemCOT PreheaterTo be installed when the operating oil temperature of the main oil system normally stays below 50°C (120°F).

COT Particle FilterA unique 3-micron filter with extra capacity to absorb temporary intrusion of unbounded water and – of course – small solid particles. Preferably installed when the main oil system runs irregularly and when the ambient environment contains significant level of humidity – with high likeliness of exposure to unbounded water. COT Oil Refiner continuously dries any – by the filter – collected water, therefore, filter replacement not needed due to water.

COT PumpA low-flow pump is installed when a reliable supply from the main oil system cannot be guaranteed, additionally, if there is a need for offline operation during longer periods of inactive system.

COT Catch Tank PumpWhen COT’s Catch Tank is selected, an evacuation pump can be placed in the tank to regularly drain the oil back to the main system.

Other Preinstalled Components:Vacuum Pump on the Air Outlet. Ensures a constant and even air flow.

Air Filter. A 2-micron air filter can be installed if COT Oil Refiner cannot be supplied with filtered and dried compressed air.

Safety Valve/Flow Control Valve. Controls oil flow and stops the system if loss of power or other mal-functions.

Electric Control System. Converts incoming power to the system’s requirement.

Additional Components Upon Request:Indicator that continuously shows the current contamination level.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 9: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

A preheater increases the incoming oil’s temperature with up to 15°C. This is to optimize COT Oil Refiner’s performance if the system’s operating temperature is below 50˚C. The preheater is thermos-tat-controlled.

COT Preheater

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 10: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Particle Filter®- Standard

Note: Max 10 bars of pressure

COT Particle filter® has two functions:(a) To catch any temporary inflow of intrusive unbound water in the main oil system. Any accumula-

ted water in the filter will be dried by COT Oil Refiner, therefore, filter replacement due to accumu-lated water in the filter element is not necessary.

(b) To act as additional filtration to the ordinary filter – filtering particles down to 3 microns.

COT Particle Filter®- HP

A filter with extra capacity – compared to the standard filter - to remove intrusive water and particles.

COT Particle Filter®- Standard COT Particle Filter®- HP

COT Particle Filter®

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 11: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Technical Data – Particle Filter HPMaterial Aluminum Alloy/SteelWeight 7 kg (15lb)Measurement (mm, inch) 305 x 170 (12 x 6.7)Filtration Rating 3 mikron, β-value=200 (acc. ISO 16889 Δp

2.5 bar) Max Particle Capacity 65 g (ISO-MTD to 2.5 bar)

Max Water Capacity 350 ml

Technical Data

Technical Data – Particle Filter StandardMaterial Aluminum Alloy/Polyamide, GE ReinforcedWeight 0,9 kg (2lb)Measurement (mm, inch) 175 x 95 (6.9 x 3.8)Filtration Rating 3 microns, β-value=200 (acc. ISO 16889 Δp

2.5 bar) Max Particle Capacity 20 g (ISO-MTD to 2.5 bar)

Max Water Capacity 60 ml

Pressure Max 10 bar

Technical Data – PreheaterWeight 1.0 kgMeasurement (mm, inch) 320 x 48Voltage 12 V-24 V DC/20 A eller 110 -230 AC/5 APower Consumption 125-145 W

Technical Data – COT Oil Refiner®Measurement (mm, inch) 175 x 150 x 140 (6.9 x 5.9 x 5.5)Voltage Oil Refiner 12 V–24 V DC/15 A or 110–230 AC/6 AVoltage Preheater 12 V–24 V DC/20 A or 110–230 AC/10 AWeight 0,5 kg (1.1lb)

Power Consumption 110 W

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 12: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner®“Det ultimata systemet för att minimera förekomsten av vatten och luft i driftsoljor”

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 13: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner® System

COT Oil Refiner® System med huvudkomponent COT Oil Refiner® är ett system för att eliminera det växande problemet med vatten- och luftinträngning i driftoljor som till exempel hydraulolja, smörj-olja, transmissionsolja med mera.

Att vatteninträngning i maskinoljor är av stor skada och orsakar mycket slitage på komponenter i olika drivsystem är känt för de flesta som arbetar med service och underhåll för olika drivsystem. Det opla-nerade driftsstilleståndet beror ofta på att någon del i drivsystemet har skadats till följd av vattenin-trängning. Vatten- och luftförekomst i oljan är oundvikligt och när förekomsten når en viss nivå upp-står oundvikligen skadligt slitage på alla delar i systemet. Genom att konsekvent reducera vattenhalten i oljan förlänger man livslängden på ingående komponenter med väsentliga kostnadsbesparingar som följd.

• Minimera risken för oplanerade driftsstopp• Minska behovet av oljebyten• Undvik slitage på rörliga delar• Minimera risker för rost• Ta bort behovet av att byta filter till följd av ansamlat vatten

COT Oil Refiner® System tar bort vatten, -och med vår vakuumversion luft- från:• Hydrauloljor• Smörjoljor• Transformationsoljor• Växellådsoljor

Fördelar:• Tar löpande bort all förekomst av fritt vattten och minskar betydligt nivån av

bundet vatten till låga PPM-nivåer.• Underlättar konvertering till syntetiska oljor.• Minskar kostnaden för service och underhåll.• Enkel att installera.• Låg driftkostnad.• Ökad livslängd för hydraulikkomponenter.• Förlänger livslängden på oljan.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 14: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner® är nyckelkomponenten i COT Oil Refiner® System. Med den patenterade metoden för punktvärmesättning frigörs vattenmolekyler från oljan utan att skapa någon risk för oxidering av oljan. Systemet skapar en betydlig reduktion av vattenförekomst i oljan. Med kompletterande komponenter kan i stort sett alla hydrauliska system använda sig av COT Oil Refiner® System.

COT Oil Refiner® ”Håller din olja fri från förorening av vatten”

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Genom att låta oljan rinna över punktvärmesatt platta, frigörs vattenmolekylerna från oljan med hjälp av styrda luftflöden.

Principen

Page 15: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Principen CatchtankPrincipen är att oljan passerar COT Oil Refiner® och flödar ner i Catchtanken. Nivån i tanken kont-rolleras av en nivågivare. När oljan når en viss nivå trycker en elektrisk pump ut oljan ur Catchtanken till hydraulsystemet. Om pumpen p g a elavbrott ej skulle vara i funktion stänger en säkerhetsventil av funktionen på Oil Refinern för att förhindra risken att olja flyter ut ur systemet. Catchtanken kan kun-danpassas efter vald utrustning.I: Catchtank i skåp (stationära installationer)II: Flexibel installation baserad på utrymme (mobila installationer)

Storlek CatchtankRekommenderad storlek på Catch tanken är 1-4 liter.

Fördelar med att installera COT Catchtank• Inga ingrepp behöver ske i hydraultanken. Oljereturen från Catchtanken är ansluten direkt till ut-

rustningens hydraulsystem.• Flexibel installation där man på ett för utrustningen optimalt sätt kan installera Catchtanken.• Kan även reducera luftinnehållet i oljan med vakumteknik.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

COT Catchtank System

II II

I

Page 16: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Hydraulic tank installation COT Catchtank installation

När?Denna installation rekommenderas då arbetstemperaturen på oljan är mellan 50-60 ˚C och risken för extraordinär vatteninträngning är begränsad.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

COT Oil Refiner® - single

Page 17: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

När?Denna installation rekommenderas när utrustningen arbetar med en oljetemperatur som understiger 50 ˚C.

COT Oil Refiner® + COT Förvärmare + COT Pump

När?Denna installation rekommenderas vid kontinuerlig drift men då arbetstemperaturen på oljan un-derstiger 50 ˚C och då det finns risk för temporärt hög vatteninträngning eller då förbättrad partikel-rening efterfrågas samt också då det finns behov av att rundpumpa oljan.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

COT Oil Refiner® + COT Förvärmare

Page 18: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Oil Refiner® kapacitet och prestanda

Kapacitet: Hur mycket vatten COT Oil Refiner® System klarar av ta bort beror på ett antal parame-trar som oljans temperatur, oljeflöde och luftfuktighet. För att uppnå optimal funktion av COT Oil Refiner® System är det viktigt att dessa parametrar optimeras. En genomsnittlig siffra för kapacitet är 5 ml/timme

50

40

30

20

10

0

60

70

80

90

100

Öppet luftintagStängt luftintagTryckluftTryckluft <10 RhVacuumpump

Luft�öde: VariationerOlja: Bio-oljaTillsatt vatten: ca 20 ml vatten, 100 RhTemperatur olja in: 55 °C/130 °FTankstorlek: 10 l

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Timmar

PPM-värde 200-250

Procent

Resultat Testrigg Relativ fuktighet(Kan variera mellan olika oljor)

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 19: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Komponenter COT Oil Refiner® System

COT FörvärmareInstalleras då oljetemperaturen i hydraulsystemet oftast understiger 50 ˚C.

COT PartikelfilterEtt unikt 3-mikrons filter med extra kapacitet att fånga tillfällig förekomst av fritt vattten (samt givetvis också små partiklar). Installeras föredragsvis då enheter arbetar oregelbundet i miljö med hög luftfuk-tighet med hög risk för bildande av fritt vatten. COT Oil Refinern torkar kontinuerligt fångat vatten i filtret varför detta inte behöver bytas p g a vatten.

COT PumpEn lågflödespump installeras då det är svårt att ta ut rätt flöde ur existerande hydraulsystem men också om det finns skäl att rundpumpa oljan då maskinen är overksam under längre perioder.

COT Catch tank pumpVid installation av COT Catch tank placeras en pump i Catch tanken för att regelbundet tömma Catch tanken.

Övriga förinstallerade komponenter:Vakumpump vid luftutflödet. Installeras för att säkerställa ett jämn luftflöde.

Luftfilter. Installeras om inte tryckluft kan anslutas för luftinflödet. Luftfiltret är på 2 mikron. Säkerhetsventil/Konstantflödesventil. Styr oljeflöde och stänger av systemet vid elavbrott.

Elstyrningsenhet. För anpassning till ingående strömstyrka.

Extra komponenter som kan anslutas på kundbegäran:Indikator som löpande visar på alla föroreningar i oljan.

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 20: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Funktion Förvärmaren ökar temperaturen på oljeinflödet med upp till 15 ˚C. Detta krävs för att optimera funk-tionen av systemet om arbetstemperaturen på oljan understiger 50 ˚C. Förvärmaren är termostatstyrd.

COT Förvärmare

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 21: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

COT Partikelfilter®- Standard

OBS! Max 10 bars tryck

FunktionCOT Partikelfilter har två funktioner:(a) Att fånga temporärt inflöde av fritt vatten i hydraulsystemet. Även om/när fritt vatten samlas i

filtret, eliminerar COT Oil Refinern ansamlat vatten varför inget filterbyte krävs vid ansamling av större kvantiteter vatten.

(b) Verka som komplement till ordinarie partikelfiltrering för partiklar ned till en storlek av 3 mikron.

COT Partikelfilter®- HPFunktionDetta partikelfilter skiljer sig från Standardfiltret genom sin extra kapacitet att binda fritt vatten och antalet partiklar.

COT Partikelfilter®- Standard COT Partikelfilter®- HP

COT Partikelfilter®” Ett unikt filter med extraordinärt vattenabsorberande element”

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]

Page 22: COT Oil Refiner® System · • Reducing the need for oil filter replacement • Avoiding wear and tear on moving parts • Minimizing corrosion • Minimizing the need for oil filter

Teknisk data - Partikelfilter HP

Material Aluminium Alloy/StålVikt 7 kgStorlek (mm) 305x170Filtreringsgrad 3 mikron, β-value=200 enligt (ISO 16889 Δp 2.5

bar) Smutshållningskapacitet 65 g (ISO-MTD till 2.5 bar)

Vattenhållning 350 ml

Teknisk data

Teknisk data - Partikelfilter Standard

Material Aluminium Alloy/Polyamide, GE FörstärktVikt 0.9 kgStorlek (mm) 178 x 95Filtreringsgrad 3 mikron, β-value=200 enligt (ISO 16889 Δp 2.5

bar) Smutshållningskapacitet 20 g (ISO-MTD till 2.5 bar)

Vattenhållning 60 ml

Tryck Max 10 bar

Teknisk data - FörvärmareVikt 1.0 kgStorlek (mm) 320 x 48Elektrisk anslutning 12 V-24 V DC/20 A eller 110 -230 AC/5 AEnergiförbrukning 125-145 W

Teknisk data - COT Oil Refiner Storlek (mm) 175 x 150 x 140Elektrisk anslutning, Oil Refiner 12 V-24 V DC/15 A eller 110 -230 AC/6 AElektrisk anslutning Förvärmare 12 V-24 V DC/20 A eller 110 -230 AC/10 AVikt 0.5 kg

Elförbrukning 110 W

COT ABBox 115SE-341 22 Ljungby Sweden

Tel: +46 733 83 71 18 E-mail: [email protected]