C O TA 3 3 H I G H S T. R E N O V AT I O N E X T E R I O R S I G N A G E 1 0 0 % C O N S T R U C T I O N D O C U M E N T A T I O N

07.11.2019

Page 2: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 1 ENVIRONMENTAL GRAPHICS

SECTION 10 14 00

ENVIRONMENTAL GRAPHICS

PART 1 GENERAL

1.01 SUMMARY

A. Section Includes

1. Architectural signage/graphics in accordance with requirements of the Contract Documents, e.g., Design Intent Drawings, Specifications, Sign Schedule and Sign Location Plans as provided by Moody Nolan Inc.

2. Contractor design: Selected Fabricator is responsible for all final Construction Documents and engineering required in the fabrication and installation of the designs, subject to approval by Moody Nolan Inc. and Owner.

1.02 REFERENCES

A. International Building Code (IBC)

B. National Association of Architectural Metal Manufacturers (NAAMM), Metal Finishes Manual

C. American Welding Society (AWS)

1. AWS D1.1 "Structural Welding Code, Steel" 2. AWS D1.2 "Structural Welding Code, Aluminum"

D. Underwriters Laboratories Inc. (UL Standards for Safety, UL Publication 48 "Electric Signs)

E. American Institute of Steel Construction (AISC)

F. American Society for Testing and Materials (ASTM)

G. Aluminum Association (AA)

H. American Architectural Manufacturers Association (AAMA)

I. American National Standards Institute (ANSI)

J. Americans with Disabilities Act (ADA)

K. Federal Specification (FS)

L. National Electrical Code (NEC)

10 14 00 - 2 ENVIRONMENTAL GRAPHICS

1.03 SIGN SYSTEM REQUIREMENTS

A. Sign System Description: Refer to the Sign Type List, Drawing Documents and Sign Location Plans for information.

B. General Requirements

1. Pre-Construction Conference: A pre-construction meeting will be held with representatives from the Owner, General Contractor, Fabricator and MOODY NOLAN INC. design team to establish the procedure for communication and coordination with the General Contractor and subsequent Trades.

2. Fabricator is required to confirm signage locations with owner prior to fabrication and installation.

3. Fabricator required to produce signage message schedule of all sign types to be reviewed and approved by owner.

4. Coordination with General Contractor: Fabricator will coordinate on-site Work and electrical hookup connections with the General Contractor. Where structural support for signage is required on the Contract Documents, it shall be provided and installed by the Fabricator, and all adjacent surfaces repaired as required, and the same holds true for removal of existing signage.

5. Sign Permits: Fabricator shall make all submittals for permits, shall be responsible for paying all fees (making adjustments as required, or any task necessary) for obtaining local building and installation Sign Permits for the proper execution of the Work.

6. All materials shall be corrosion-resistant. 7. Structural Elements: Signs shall be securely fastened with provisions for

repair, replacement and routine maintenance without destruction or dismantling the sign and/or surrounding structure(s).

8. Structural Design a. Provide exterior sign assemblies designed, tested, and installed,

to withstand positive and negative wind loads per site requirements approved by a licensed structural engineer, registered in the State work is being done in. 1) Furnish engineering calculations to show that maximum

stresses and deflections of signage, and signage support system; do not exceed specified performance requirements under full design loading. Calculations shall be prepared and sealed by the engineer responsible for their preparation.

9. Connections: Fasteners, anchorages and metal support systems shown on the signage Drawings are suggestive only, and are intended as a guideline to clarify intent of the specification, functional and design requirements and coordination requirements. Provide additional anchorage, support framing and bracing as necessary to meet loading requirements and building conditions. No additional connections shall be visible in finished construction.

10. Markings and Labels: Locate markings, labels, manufacturer names and other identifications so as to be concealed from public view and as acceptable to MOODY NOLAN INC. and the Owner.

PROJECT PERFORMANCE SPECIFICATIONS

Page 3: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 3 ENVIRONMENTAL GRAPHICS

11. Evacuation Map Art: NOT REQUIRED 12. Sign Schedule

a. The Sign Schedule is the only document that should be used to determine sign messages. It is the responsibility of the Fabricator to create and manage the message schedule with the owner. Since signs often change between the award of bid and the fabrication process, Fabricator should coordinate with General Contractor and MOODY NOLAN INC. to ensure that modifications to the sign system, or plan information is current. Fabricator should submit a Sign Schedule to the Owner to confirm the accuracy of the messages, for final approval. 1) Text Verification: Provide a list of all text to be included on

signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final wording on signage is subject to confirmation and possible revision by the Owner, after award of the Contract, prior to fabrication.

13. Final Location of Signs: The location of signs as shown on the Sign Location Plans is for general reference only and in some cases is not representative of the exact final location. Final locations of signs shall be field located in coordination with MOODY NOLAN INC., Owner, General Contractor and Engineer at the site. Fabricator shall arrange for meetings at the site to accommodate direction of final locations according to project schedule.

14. Dimensions: Written dimensions on Drawings shall have precedence over scaled dimensions. Fabricator shall verify and be responsible for all dimensions and conditions shown by these Drawings. Fabricator-produced Shop Drawings, and details therein must be approved by MOODY NOLAN INC. prior to fabrication.

15. Discrepancies: Fabricator must notify MOODY NOLAN INC. , Owner, and General Contractor immediately if any discrepancies exist in the Drawings, Sign Schedule, Location Plans, or in field conditions that would necessitate changes in construction details or dimensions. Fabricator must cross-reference all parts of Contract Documents. Fabricator must notify MOODY NOLAN INC., Owner, and General Contractor immediately if any discrepancies, or inconsistencies exist between or within the parts of the Contract Documents (Drawings, Sign Schedule, Location Plans or Specifications).

16. Rights to Designs: Fabricator may not manufacture, reproduce, or exhibit these designs, or modify them for any other purpose outside of this current contract without written approval of MOODY NOLAN INC. and the Owner.

1.04 SUBMITTALS

A. Product Data: Submit for information. Furnish within seven (7) days of request, manufacturer's literature describing the general properties of each product to be used in the Work.

B. Shop Drawings

10 14 00 - 4 ENVIRONMENTAL GRAPHICS

1. Provided by Fabricator, signed and stamped by licensed Structural Engineer, to be submitted for review and approval by MOODY NOLAN INC.

2. Submit elevations, details of fabrication and erection, including all materials, shapes, dimensions, finishes, wind load calculations, anchorage, and method of connections. Show proper letter spacing and dimensions of letter heights.

C. Samples and Patterns

1. Color and Material Samples: Provide two (2) sets of 12” x 12” non-returnable samples of all materials, color, and finish as specified.

2. Full Size Patterns and Lettering: Provide full-size patterns of each sign (or scaled layouts for signs with lettering over 3” in height) with solid black letter forms and graphic elements on a white background with sign perimeter outlined. Typography must be represented in exact typeface and letter spacing specified and/or shown in Drawings. Sign layouts and lettering patterns shall be submitted as film positives, ink-jet plots, or laser copies, produced from digital camera-ready artwork.

D. Mock-Ups and Prototypes: Provide two (2) mock-ups of each sign type noted, delivered to designer for review. MOODY NOLAN INC. will return mock-ups for use in the facility.

1. The required sign types are: a. Sign Type EX2 (1 letter) b. Sign Type EX3 (Partial size, showing full size details) c. Sign Type EX7 (Partial size, showing full size details) d. Sign Type EX1 (Partial size, showing full size details) g. Color Samples ( 4” x 4” color control samples of all painted colors)

2. Utilize the same materials and installation methods in the mock-up(s) as intended for the final Work. Schedule the installation so that the mock-up(s) may be examined, and any necessary adjustments made, prior to commencing fabrication of the final Work. Replace unsatisfactory items as directed. When accepted, mock-up(s) shall serve as the standard for materials, workmanship, and appearance for such Work throughout the project.

E. Maintenance Data and Materials

1. Maintenance and Operating Manuals: Submit two (2) copies to General Contractor for Owner's documentation and one (1) copy for MOODY NOLAN INC.'s documentation. Furnish complete manuals describing the materials, devices and procedures to be followed in operating, cleaning and maintaining the Work. Include manufacturers' brochures and parts lists describing the actual materials used in the Work, including metal alloys, finishes, electrical components and other major components. Assemble manuals for component parts into single binders identified for each system.

2. Instruction: Prior to acceptance, establish with the Owner an instruction and training program for Owner's personnel. Notify the Owner in writing

PROJECT PERFORMANCE SPECIFICATIONS

Page 4: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 5 ENVIRONMENTAL GRAPHICS

at least seven (7) days prior to commencement of the program providing an outline of topics indexed to the Maintenance and Operating Manual. Provide a trained instructor. Provide one (1) 4-hour period of training scheduled during the normal 8-hour working day. Instruction and training shall include, but are not limited to, procedures to be followed in the normal day-to-day maintenance and operation of the Work.

3. Maintenance Materials: Deliver to the Owner the following, in manufacturer's original packaging, and store at the project site where directed. a. One (1) gallon of each finish paint color for touch-up purposes b. Six (6) lamps of each type and size used in the signage c. Extra name strips and sign inserts for changeable signs in a

quantity that is 20% of the total count per relevant sign type, minimum five (5).

1.05 QUALITY ASSURANCE

A. Fabricator Qualifications: Provide the following documentation to the Owner, General Contractor, and MOODY NOLAN INC.:

1. Direct fabricating experience in producing signs similar to those indicated for the Work, with a record of successful in-service performance, proven craftsmanship, and sufficient production capacity to produce sign units required without causing delay in the Work.

2. Minimum of five (5) years documented, successful experience in the manufacture, installation and maintenance of similar sign types. References required upon request.

3. Manufacture majority of sign components in their own fabrication facility, and furnish remaining components manufactured by reputable and reliable suppliers.

4. Furnish qualified, competent, experienced, on-staff installers and supervisory personnel.

5. Maintain a service capacity, which is capable of satisfactorily furnishing parts and labor for maintenance and repair service, for the duration of the warranty.

B. Work-In-Progress Approvals: Provide work-in-progress sign elements for review. Scheduled or unscheduled viewing at the shop or factory may be initiated as deemed necessary to ensure continued quality control and to make any adjustments required during fabrication. Unsatisfactory items are to be corrected by the Fabricator as directed at no additional cost to the Owner.

C. Regulatory Requirements: Comply with applicable requirements of the laws, codes, ordinances and regulations of Federal, State and Municipal authorities having jurisdiction. Obtain necessary approvals and permits from all such authorities as required.

10 14 00 - 6 ENVIRONMENTAL GRAPHICS

D. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use.

E. Lettering

1. Fabricator shall be responsible for the quality control of all lettering. All letterforms shall be crisp, sharp, and free of nicks, ragged edges and discontinuous curves. All lettering shall conform to approved typeface, weight and letter spacing.

2. Typeface: No substitutions of typeface foundry, brand or version or implementation technique will be accepted without prior approval. Unapproved letterforms shall be replaced at Fabricator's expense. Fabricator is responsible for purchasing all electronic font products for the specified typefaces in the project. MOODY NOLAN INC. will not supply copyrighted font software to the Fabricator.

3. Vinyl Die-Cut Graphics: All artwork shall be derived from computer artwork for cutting on late-generation Gerber professional sign making equipment or approved equal.

4. All cutting and routing shall be executed in such a manner that all edges and corners of finished letterforms are true and clean. Letterforms with rounded positive or negative corners, nicked, cut, or ragged edges, etc., will not be accepted. All letterforms shall be so aligned as to maintain a baseline square and level with the sign format, unless otherwise specified. Margins around letters, and also in relation to sign edges must be maintained as specified on the Drawings. Fabricator to notify MOODY NOLAN INC. , if message length causes letters to fall within the specified margins.

F. Quality of Workmanship: Fabricator shall be responsible for the quality of all materials and workmanship required for the execution of this contract including materials and workmanship of any firm or individual whom act as Fabricator's subcontractor. Fabricator shall be responsible for providing up-to-date Drawings, Specifications, Sign Schedule, etc., to all subcontractors.

1.06 PROJECT CONDITIONS

A. Field Measurements: Where dimensions of surfaces on which they are installed determine sizes of signs, verify dimensions by field measurement prior to fabrication and indicate measurements on Shop Drawings.

Fabricator to notify MOODY NOLAN INC. immediately, if discrepancies exist between Drawings and field conditions.

1.07 WARRANTY

A. Fabricator and Installer agree to repair or replace Work that has failed as a result of defective material, workmanship, or installation.

Failure is defined if any of the following occurs within three (3) years of the acceptance of Work by the Owner, or other agreement period determined between the Owner and the Fabricator:

PROJECT PERFORMANCE SPECIFICATIONS

Page 5: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 7 ENVIRONMENTAL GRAPHICS

1. Electrolytic decomposition of any metal 2. Oxidation or rusting of any metal 3. Dissociation of fasteners, anchors, welds, or any other connecting

devices 4. Delaminating of graphic materials and substrates 5. Pitting or non-adhesion of finishes or coatings 6. Sign panel warping or oil canning 7. Fading and/or non-uniform fading of color 8. Malfunction of electrical components 9. Failure of structural components or systems 10. Failure or sinking/settling of sign footings

B. Fabricator shall replace/repair any defective work within thirty (30) days after notification by the Owner throughout the duration of this period.

C. Linear Polyurethane Paint Factory Finish Warranty: Submit to General Contractor for Owner's documentation. Furnish five (5) year written warranty, warranting that the factory-applied linear polyurethane finishes will not develop excessive fading or excessive non-uniformity of color or shade, and will not crack, peel, pit, corrode or otherwise fail as a result of defects in materials or workmanship within the following defined limits:

1. Excessive Fading: A change in appearance, which is perceptible and objectionable as determined when visually compared with the original color range standards.

2. Excessive Non-Uniformity: Non-uniform fading to the extent that adjacent panels have a color difference greater than the original acceptable range of color.

3. Will Not Pit or Otherwise Corrode: a. No pitting or other type of corrosion, discernible from a distance of

10'-0”, resulting from the natural elements in the atmosphere at the project site.

4. Upon notification of such defects, within the warranty period, make necessary repairs or replacement at the convenience of the Owner.

PART 2 PRODUCTS

2.01 SIGN MATERIALS

A. Acrylic Sheet Plastic: Thickness shall be as indicated on Drawings. Fabricator shall provide color and finish samples of all plastics for approval before fabrication; no substitution in color, thickness, or finish of plastics will be accepted without written approval. All plastics shall be of uniform color, translucence and illumination, as supplied by manufacturer. Any exposed edges of acrylic shall be finished so as no saw marks are visible.

B. Adhesives

1. Silicone adhesive used for installing signs shall be manufactured by Dow Corning (or equal).

10 14 00 - 8 ENVIRONMENTAL GRAPHICS

2. Polyfoam contact adhesive tape manufactured by 3M shall be used in conjunction with silicone adhesives for installation of wall signs.

C. Anchors and Inserts: Use nonferrous metal or hot-dipped galvanized anchors and inserts for exterior installations and elsewhere as required for corrosion resistance. Use toothed steel or lead expansion bolt devices for drilled-in-place anchors. Furnish inserts, as required, to be set into concrete or masonry work.

D. Brackets: Fabricate brackets and fittings for bracket-mounted signs to suit sign panel construction and mounting conditions indicated. Factory-paint brackets as indicated.

E. Concrete Foundation: Provide structurally engineered concrete footings/foundations and non-structural (mow-strip) pads at grade (in landscaped areas only) to meet local building code requirements.

F. Decal or Transfer: Provide special printed-paper or vinyl suitable for reproducing the design onto material indicated, as required. Submit samples for approval.

G. Fasteners

1. Provide bolts, nuts, screws, washers, anchors and other devices required to complete the Work.

2. Use same basic metal or alloy as the metal fastened and finished to match in color and texture. Stainless steel 300 series alloy where used to join dissimilar materials.

3. Use stainless steel, counter-sunk socket head fasteners where not specified in Drawings.

H. Foam Tape: Provide concealed polyurethane foam tape as manufactured by 3M, applied to sign elements as required.

I. Glass Fiber-Reinforced Pre-Cast Concrete Base Design: GFRC bases by registered professional engineer employed or retained by panel manufacturer licensed to practice in the State the sign is being installed in, using property generated from manufacturer's actual production.

Comply with procedures in Pre-stressed Concrete Institute (PCI) MNL-128-97 "Recommended Practice for Glass Fiber-reinforced Concrete".

1. Forms: Construct of rigid materials that will result in finished products conforming to profiles dimensions, and tolerances indicated. Use form release agent compatible with architectural finish and joint sealants.

2. Mixes: Combine Portland cement, glass fibers, sand and selected admixtures, in proper proportions to meet design requirements.

J. Hardware/Hinges

1. Provide and install all incidental hardware necessary for the proper functioning of the signs, including but not restricted to materials and products covered in this section.

PROJECT PERFORMANCE SPECIFICATIONS

Page 6: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 9 ENVIRONMENTAL GRAPHICS

2. Provide concealed stainless steel hinges for all hinged access panels. Provide concealed pin tumbler locks for all access panels requiring locks. Provide stainless steel fasteners for assembling ferrous and nonferrous metals. Where specific metal finishes need to be matched, exposed stainless steel hinges must be plated or dipped.

K. Metals

1. Aluminum shall be suitable for ornamental, architectural work. Surface finish shall be smooth, free of extrusion marks or imperfections. Alloy shall be selected to meet the structural requirements of the specific application.

2. Stainless steel shall be suitable for ornamental and architectural work. Provide stainless steel plate, sheet or strip AISI Type 302, complying with requirements of ASTM A 167. Surface finish shall be smooth, free of all extrusion marks or imperfections. Alloy shall be selected to meet the structural requirements of specific application.

3. Structural metal for concealed framing shall be of galvanized rolled steel (or equal), as required, satisfying structural requirements.

4. Aluminum Sheet: Provide aluminum sheet of alloy and temper recommended by the sign manufacturer for the type of use and finish indicated, and with not less than the strength and durability properties specified in ASTM B 209 for 5005-H15.

5. Aluminum Extrusions: Provide aluminum extrusions of alloy and temper recommended by the sign manufacturer for the type of use and finish indicated, and with no less than the strength and durability properties specified in ASTM B 221 for 6063-T5.

6. Dissimilar Metals Isolation: Separate all ferrous and nonferrous metals with nonconductive gaskets to prevent electrolysis. In addition to gaskets, provide stainless steel fasteners as required.

L. Polycarbonate Plastic Sheet: Tuffak or Lexan polycarbonate sheet as manufactured by Atohaas, or GE Plastics. Provide polycarbonate sheets that are abrasion and high-impact resistant, and durable against weather conditions. Thickness shall be as indicated on Drawings. Fabricator shall provide color and finish samples of all plastics for approval before fabrication; no substitution in color, thickness, or finish of plastics will be accepted without written approval.

All plastics shall be of uniform color, translucence and illumination, as supplied by manufacturer. Any exposed edges of acrylic shall be finished so as no saw marks are visible.

M. Rigid Rod or Flexible Steel Cable Supports: High quality steel or aluminum per load and seismic requirements. Provide metal swivel connectors to allow signs to give or swing as required per code. Prime and paint all parts as specified (bronze sleeves and escutcheon plates to be US10B finish).

N. Tactile / Braille: Tactile copy shall comply with ADA Accessibility Guidelines. Raised copy thickness not less than 1/32 inch (0.8mm). Grade 2 Braille shall accompany tactile copy. Produce precisely formed characters with square cut

10 14 00 - 10 ENVIRONMENTAL GRAPHICS

edges free from burrs and cut marks. Fabricator is responsible for proper and accurate Grade 2 Braille translation.

O. Welding Electrodes and Filler Metal: Provide the alloy and type required for strength, workability, compatibility and color match after grinding smooth and finishing the fabricated product as required.

P. Wood Materials: Provide premium grade of wood materials specified when the finish is transparent. Custom grade of wood material may be used for opaque finishes. High quality of workmanship is required for all woodworking.

2.02 ELECTRICAL COMPONENTS

A. Power Supplies: As required for internally illuminated cabinet signs, in quantity and arrangement as recommended by power supply manufacturer. Accessible for maintenance.

B. Conduit and Devices: Provide rigid steel conduit, junction boxes and associated devices in accordance with applicable codes as required.

C. Disconnect Switch: All signs or sign components with electrical service shall be equipped with an approved external disconnect switch, flush mounted on the cabinet/sign, with circuits and capacity to control all primary wiring within the sign. Location of switch must be shown on Shop Drawings and is subject to approval. Lock-out to be provided when sign is accessed from either side of an wall.

D. Electrical Wiring and Equipment: Provide and install electrical materials such as Power supplies, transformers, lamps, sockets, neon units, connectors, and all other equipment which shall be new and UL approved. The assembly of all components within the illuminated signs shall conform to all standards of UL as published in the latest edition of "Standards for Sign Safety", and all illuminated signs shall bear the UL label. All wiring and equipment shall be concealed within the sign structure.

E. Illumination: All signs with LED illumination to provide even illumination without light leaks. The Fabricator shall provide all LED modules and power supplies. Provide waterproof flush access panel(s), concealed wherever possible.

Fabricator shall provide conduit wiring and electrical equipment from the field electrical connection to any part of the sign and within the sign.

F. LED Lighting: Provide LED lighting with high optical performance for each beam spread, UV stability, and excellent longevity, with low profile housing.

G. Neon Sign Lighting

1. Neon Tubing (Concealed Neon and/or Exposed Neon): Form neon tubing in the shape of each letter, using tubes individually filled at optimum pressure required for uniform lighting.

2. Electrodes: "Type 8C", Engineering Glass Laboratories, Newark, NJ.

PROJECT PERFORMANCE SPECIFICATIONS

Page 7: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 11 ENVIRONMENTAL GRAPHICS

3. Tube Supports: Buttress threaded glass posts, not less than 3/8" (9.5 mm) diameter adjustable type. Securely attach tubes to supports with pure annealed copper wire ties, without strain on tubing.

4. Transformers: 4030 low power factor types, loaded not in excess of 85% of manufacturer's maximum recommended footage of neon tubing.

5. Power Distribution a. Not less than 12 Ga. THW rubber covered copper wire for all

primary circuit wiring. 15 kV type-high tension cable, insulated from metal by nonporous ceramic supports and/or tubes.

b. Provide raceways of 16 Ga. (1.6 mm) Zinc-Grip A metal with enamel finish, and 1-1/2" x1-1/2" (38 x 12.5 mm) by 1/4" (6 mm) galvanized steel angles.

H. Ventilation: While maintaining a proper weather seal, provide for sufficient ventilation of sign components to prevent overheating or warping. In providing for ventilation, protect sign from elements (rain, wind, debris, etc.) that might cause operational or cleaning problems. Signs/cabinets with light leaks will not be accepted.

I. Wiring: Minimum #12 AWG copper. High-tension wiring shall not be less than GTO 15 wire as manufactured by Carol Cable Company or approved equal. All wiring shall be AWM 90 0 centigrade 1000-volt TW/MTW UL file no. 18971. Wiring connectors for wire splicing shall be UL-approved 1000-volt capacity. They shall be Scotch Lock type Y or R, (or equal). All splices shall be placed as to easily access for inspection.

2.03 FINISHING MATERIALS

A. Anodized Aluminum Components/Panels: If required, provide anodized (application of aluminum oxide film coating in clear or colored dye finish) aluminum panels or parts to match MOODY NOLAN INC. ’s color, grain, finish and Specifications.

B. Linear Polyurethane Coatings: Provide the following, or other products as acceptable:

1. Acrylic Linear Polyurethane enamel: Two components, acrylic aliphatic isocyanate/acrylic polyurethane having ultraviolet (UV) inhibitors and engineered for exterior application by Matthews Paint Company or approved equal.

2. Primer for Aluminum: Two part component primer: One-coat Matthews 74-734 and 74-735 Metal Pre-treat at 0.25 mils dry film thickness or one-coat Matthews 74-793 Spray Bond at 0.15 to 0.25 mils dry film thickness or Wyandotte/AKZO Grip-Guard Wash Primer (2Afy-31284) with Grip-Guard Wash Primer Hardener (10AFK-31285) combined and applied per manufacturer's specifications or approved equal (primer) for the application of the pre-approved and pre-formulated paint system.

3. Primer for Steel: Two-part component primer: One-coat Matthews 74-734 and 74-735 Metal Pre-treat at 0.25 mils dry film thickness or

10 14 00 - 12 ENVIRONMENTAL GRAPHICS

Wyandotte/AKZO Grip-Guard Wash Primer (2Afy-31284) with Grip-Guard Wash Primer Hardener (10AFK-31285) combined and applied per manufacturer's specifications or approved equal for the application of the pre-approved and pre-formulated paint system.

4. Clear Sealers: Crystal-clear satin polyurethane sealers by Matthews Paint Company or approved equal. Sealers are to resist rust and corrosion associated with exposure to salt air as required, and of highest quality available, applied per manufacturer's specifications.

C. Vinyl Die-Cut and Pattern Cut-Out Graphics: Use 3M Scotchcal Opaque, Translucent or Scotchlite Reflective sheeting where specified. Use pressure-sensitive, non-yellowing, non-peeling and weather resistant vinyl as specified. Use approved fonts and equipment as specified.

2.04 FABRICATION OF SIGNS AND SUPPORTS

A. General: Provide custom-manufactured sign assemblies, components completely fabricated and finished at factory before delivery to site. Construct to accurate detail and dimensions as shown on Shop Drawings and as reviewed. Fit and assemble the Work at the shop to the greatest extent possible, and mark the components as required to facilitate assembly during installation. No site application or finishing will be permitted except for touch up. Exposed fasteners on finished faces will not be allowed, unless specifically indicated. Waviness and oil canning of surfaces are not acceptable. Minimum material thickness is to be 0.090 inches. Conceal wiring, conduct and other electrical items within sign enclosures.

B. Castings: Exposed surfaces uniformly free from porosity and roughness. Edges filled and ground smooth. Faces chemically etched and mechanically polished for specified finish.

C. Galvanizing: Provide for steel components in exterior construction, and where noted to be galvanized. Complete the shop fabrication prior to application of the zinc coating. Remove mill scale and rust, clean and pickle the units as required for proper pre-treatment of the surfaces.

D. Hardware: Provide all incidental hardware necessary for the proper functioning of signs. External hardware shall conform to the external appearance of the sign. Where accessible to the public, provide vandal-resistant hardware.

E. Illuminated Signage: Provide with UL labels and in accordance with UL Publication 48.

1. Electrical Service: Coordinate electrical components and demands with building power supplies. Where three (3) phase signs occur, arrange ballast’s to evenly distribute the load over all phases.

2. Power Distribution: Provide all internal wiring for ballasts and lamps. Connect to load side of disconnect switch.

3. Voltage Regulation: Provide adequate space within sign enclosure to accommodate transformers for voltage regulation should excessive voltage drop occurs.

PROJECT PERFORMANCE SPECIFICATIONS

Page 8: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 13 ENVIRONMENTAL GRAPHICS

4. Disconnect Switches: Install within sign enclosure. When not possible to install within sign enclosures, locate where concealed from public view and as acceptable to MOODY NOLAN INC. .

F. Metal Signs and Supports: Fabricate exposed surfaces uniformly flat and smooth, without distortion, pitting, or other blemishes. Form exposed metal edges to a smooth radius. Permanently bond laminated metal components and honeycomb core with adhesive or sealant in accordance with product manufacturer's recommendations. Grind exposed welds and rough areas to make flush with adjacent smooth surfaces.

1. Welding: Make welds continuous. Comply with American Welding Society, Aluminum Association, and Copper Development Association standards for the type of metal.

2. Fasteners: Use exposed fasteners only where indicated. Perform drilling and tapping at the shop.

3. Dissimilar Materials: Where metal surfaces will be in contact with dissimilar metals or materials, coat the surfaces with epoxy paint or plate with zinc chromate and provide non-conductive isolating material or other means of dielectric separation as recommended by manufacturer to prevent galvanic corrosion.

G. Seams and Joints: Added joints shall be ground filled and finished flush and smooth with adjacent work. Such seams shall be invisible after final finish has been applied. Spot welded joints shall not be visible on exterior of signs after final finish has been applied. No visible gaps, light leaks, waves, welds, or oil canning will be permitted in the Work.

H. Supports and Backing in Walls: Fabricator shall provide engineered sign supports anchored to building structure where required and to meet requirements of applicable building codes. Support or backing requiring installation within the building wall construction shall be immediately relayed to the General Contractor for field coordination.

2.05 SHOP APPLICATION OF SIGN FINISHES

A. Linear Polyurethane Finishes: Clean the surfaces as required for proper adhesion of coatings. Use 3M “Scotch Brite” pads with cleanser and water, and/or chemically treat as recommended by paint manufacturer to remove deleterious film or residue.

1. Linear Polyurethane Paint: Provide pretreatment and primer in accordance with manufacturer's recommendation. Add ultra violet inhibitors to paint subject to sunlight exposure.

2. Clear Linear Polyurethane Finish: Provide pretreatment, primer, and matte or semi-gloss finish coatings in accordance with manufacturer's recommendations. Actual gloss level to be determined by MOODY NOLAN INC. , based on samples. Apply 1.5 to 2.0 mils dry film thickness.

10 14 00 - 14 ENVIRONMENTAL GRAPHICS

B. Metal Finishes: Remove scratches, abrasions, dents and other blemishes before applying finish. Apply the finish to the fabricated Work, with texture and reflectivity as required to match MOODY NOLAN INC. 's sample or Specifications. Where no finish is specified for metal, provide random orbital satin finish, with a protective clear coat.

C. Sign Graphics: Provide the letters, numerals, symbols, and other graphics markings, using the finish materials as indicated on Drawings. Apply the graphics neatly, uniformly proportioned and spaced, and accurate within the dimensions indicated. Prepare the substrate surfaces and apply finish materials in accordance with manufacturers' instructions.

2.06 SHOP APPLICATION OF GRAPHICS

A. Preparation: Surfaces to receive the graphic markings shall be clean, dry, and otherwise made ready for application of the materials. Accurately measure and lay out the required marking configurations as indicated on Drawings.

1. Painted or Screen-Printed Graphics: All graphics to be applied using photo processed screens from camera ready digital art, arranged to furnish sharp and solid images without edge buildup or bleeding of the coating. Comply with coating manufacturer's application instructions. Provide proper type of primer to suit each substrate and obtain a permanent bond. Verify compatibility of each substrate with the coatings to be used in the Work. Apply the markings with neat edges, minimum 3 mils (0.075 mm) dry film thickness and as required to obtain solid markings without voids or fading.

2. Vinyl Die-Cut and Pattern-Cut Graphics: Pressure sensitive, non-yellowing, non-peeling and weather resistant vinyl adhesive letters or images, custom flood coated as required, die-cut from Scotchcal or Scotchlite manufactured by 3M, as specified. Apply in strict accordance with manufacturer's instructions. Make uniformly smooth and free from bubbles, wrinkles, stretching and blemishes.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verification of Conditions: Examine the areas to receive the Work and the conditions under which the Work would be performed. Fabricator shall remedy conditions detrimental to the proper and timely completion of the Work, coordinating with the General Contractor. Do not proceed until unsatisfactory conditions have been corrected.

3.02 INSTALLATION

A. General: Complete installation shall be in accordance with manufacturers' printed instructions and accepted Shop Drawings, to produce Work complying with the Contract Documents. Fabricator will be responsible for daily cleanup of signs and their areas of work.

PROJECT PERFORMANCE SPECIFICATIONS

Page 9: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

10 14 00 - 15 ENVIRONMENTAL GRAPHICS

B. Erection of Signs: Set and attach the Work accurately in location, alignment and elevation, plumb, level and true, as measured from established reference points and from other Work already in place. Fit components accurately together to form tight joints and secure connections. Coordinate, through the General Contractor with other trades and make connections of illuminated signs to electrical service. Exterior wall penetrations and blocking are to be coordinated immediately upon award of contract. Test illuminated sign components in shop and adjust operation for proper performance prior to installation.

C. Interior Wall Signs: Install signs on walls indicated, or adjacent to latch side of door where applicable. Where not indicated or possible, such as double doors, install signs on nearest adjacent wall. Locate to allow approach within 3 inches (75mm) of sign without encountering protruding objects or standing within swing of door.

3.03 ADJUSTING

A. Neatly repair minor blemishes or marring on finished surfaces so that repairs are imperceptible. Completely replace components having permanent non-removable scratches, stains, or other defacement.

3.04 PROTECTION

A. Protect the Work during the construction period so that it will be without any indication of use or damage. Leave the Work clean and free from defects at the time of acceptance. Protect Work from weather, and protect exterior walls from weather where signage installation requires penetration of walls.

B. Ensure bystander safety during installation by using barricades, barriers, and personnel as required by all applicable codes.

3.05 CLEANING

A. Upon completion of the Work, remove unused materials, debris, containers and equipment from the project site.

Remove protective coverings and clean the exposed surfaces of the Work to remove dirt, stains and other substances, by methods as recommended by manufacturer.

3.06 FINAL WALK-THROUGH AND PUNCH-LIST

A. Final walk-through will be held with MOODY NOLAN INC. , the Owner and General Contractor to review the finished installation. Fabricator will prepare a punch-list of all items requiring modification. Owner, General Contractor and MOODY NOLAN INC. reserve the right to reject all or part of signs that do not correspond to the Design Intent Drawings and Specifications or the approved Shop Drawings, lettering patterns, color and material samples or prototypes, etc.

3.07 FABRICATION ERRORS

A. If the Fabricator has made an error in copy (message), color, material, quality, etc. these items must be corrected within thirty (30) days of observation of error

10 14 00 - 16 ENVIRONMENTAL GRAPHICS

(at no additional cost). Fabricator will be notified with a written punch-list as errors are discovered.

3.08 REPAIRS AND REPLACEMENTS

A. Clean up, repair, or replace at no cost to Owner all property damaged by reason of the required Work, including restoring all disturbed areas, surfaced and un-surfaced, to the original condition on completion of the Work as approved. Work potentially impacted includes pre-cast, brick, ornamental metal, gypsum board, millwork, windows, fixtures, landscape, etc. All patchwork or replacement shall match existing as to be imperceptible. Painted surfaces shall be painted to match the adjacent areas. Painting shall extend to include the entire plane of the surface subjected to a line where an inconspicuous break can occur, as directed by the Owner's Representative. Avoid damaging existing conditions and protect existing surfaces from impacts due to installation of the Work.

END OF SECTION

PROJECT PERFORMANCE SPECIFICATIONS

Page 10: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 10

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

SITE SIGNAGE LOCATION PLAN

COTA logo signage

Building name signage

Glass graphic / lighting

No Smoking...

Hours of operation

No Guns...

No public Restroom

No Food or Drink Inside

Employees Only, Visitors please..,

CODE GRAPHIC TYPE

Exterior Signage

EX1

EX2

EX3

EX4

EX5

EX6

EX7

EX8

EX9

EX3

EX6

EX4

EX5EX1

EX2EX7EX8

EX9

Page 11: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 11

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

Exterior -Night view

EX3

EX1

EX2

EX5

EX4

EX7 EX8

EX6

Page 12: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 12

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

Exterior -Day view

EX3

EX1

EX2

EX5

EX4

EX7 EX8

EX6

Page 13: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 13

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

WilliamJ. LhotaBuilding

• SHORT NORTH • HIGH ST • ARENA DISTRICT •EASTON • POLARIS • OHIO STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • GAHANNA • GERMAN VILLAGE • SCHILLERCOSI • VETERAN'S MEMORIAL • FRANKLIN PARK CONSERVATORY • NATIONWIDE ARENA • ZOO •BREWERY DISTRICT • DUBLIN • WORTHINGTON • WHITEHALL •JOHN GLENN AIRPORT • CMH • SCIOTA MILE • AUDOBON • NORTH MARKET • BEXLEY •CAPITOL BUILDING • LINDEN • UPPER ARLINGTON • NOBO •OLD TOWN EAST • COTA • ITALIAN VILLAGE • MARION • SHORT NORTH • HIGH ST • ARENA DISTRICT •EASTON • POLARIS • OHIO STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • • SHORT NORTH • HIGH ST • ARENA DISTRICT •EASTON • POLARIS • OHIO STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • GAHANNA • GERMAN VILLAGE • SCHILLERCOSI • VETERAN’S MEMORIAL • FRANKLIN PARK CONSERVATORY • NATIONWIDE ARENA • ZOO •BREWERY DISTRICT • DUBLIN • WORTHINGTON • WHITEHALL •JOHN GLENN AIRPORT • CMH • SCIOTA MILE • AUDOBON • NORTH MARKET • BEXLEY •CAPITOL BUILDING • LINDEN • UPPER ARLINGTON • NOBO •OLD TOWN EAST • COTA • ITALIAN VILLAGE BREWERY DISTRICT • DUBLIN • WORTHINGTON • WHITEHALL •JOHN GLENN AIRPORT • CMH • SCIOTA MILE • AUDOBON • NORTH MARKET • BEXLEY •CAPITOL BUILDING • LINDEN • UPPER ARLINGTON • NOBO •OLD TOWN EAST • COTA • ITALIAN VILLAGE • MARION • SHORT NORTH • HIGH ST • ARENA DISTRICT •EASTON • POLARIS • OHIO STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • • SHORT NORTH • HIGH ST • ARENA DISTRICT •EASTON • POLARIS • OHIO STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • GAHANNA • GERMAN VILLAGE • SCHILLERCOSI • VETERAN’S MEMORIAL • FRANKLIN PARK CONSERVATORY • NATIONWIDE ARENA • ZOO •BREWERY DISTRICT • DUBLIN • WORTHINGTON • WHITEHALL •JOHN GLENN AIRPORT • CMH • SCIOTA MILE • AUDOBON • NORTH MARKET • BEXLEY •CAPITOL BUILDING • LINDEN • UPPER ARLINGTON • NOBO •OLD TOWN EAST • COTA • ITALIAN VILLAGE STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • GAHANNA • GERMAN VILLAGE • SCHILLERCOSI • VETERAN’S MEMORIAL • FRANKLIN PARK CONSERVATORY • NATIONWIDE ARENA • ZOO •BREWERY DISTRICT • DUBLIN • WORTHINGTON • WHITEHALL •JOHN GLENN AIRPORT • CMH • SCIOTA MILE • AUDOBON • NORTH MARKET • BEXLEY •CAPITOL BUILDING • LINDEN • UPPER ARLINGTON • NOBO •OLD TOWN EAST • COTASTATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • GAHANNA • GERMAN VILLAGE • SCHILLERCOSI • VETERAN’S MEMORIAL • FRANKLIN PARK CONSERVATORY • NATIONWIDE ARENA • ZOO •BREWERY DISTRICT • DUBLIN • WORTHINGTON • WHITEHALL •JOHN GLENN AIRPORT • CMH • SCIOTA MILE • AUDOBON • NORTH MARKET • BEXLEY •CAPITOL BUILDING • LINDEN • UPPER ARLINGTON • NOBO •OLD TOWN EAST • COTA STATE • CMA FRANKLINTON • GRANDVIEW • GOODALE PARK • GAHANNA • GERMAN VILLAGE • SCHILLER

EXTERIOR ELEVATION - EASTSCALE: 1/4” = 1’-0”1

Dimensional building name lettering-Pin-mounted to column face at same height as adjacent address numbers-Left justified copy-Centered vertically on column face-5 1/2” Cap height-Dark bronze to match address #s-Field verify matching Dark Bronze color

Translucent “Etched” look second surface applied vinyl copy-Wording to be COTA Destinations-Final Copy TBD-Interior RGB LED wall washer down lighting to illuminate applied vinyl copy at upper glass portions of the outside facing glass vestibule surfaces

Existing items to remain-Address Numbers “33”-Ohio Manufacturing Association sign-Building directory, galvanized, (Not shown)

Existing items to be refurbished, 3 Plaques, Approximately 12” wide x 15” tall -Cast Plaques “No Sitting,....” to be removed and refurbished and re-installed at same locations-Remove plaques and chemically remove clear coat-Remove oxidation and re-grain raised metal-Repaint background to match existing and apply new clear coat-See last page for additional information

Applied Vinyl Copy and Graphics-Second surface precision cut white vinyl-Types EX4 to EX9-Test application required to ensure legibility-Final Vector artwork provided by architect

9’-0” +/- Field verify

18” +/-

Typical section on following page

8” +/- 7” +/-

Face-lit channel letters attached to angled building fascia-Internally illuminated -Red-Power penetration required for each letter/form-Mounts flush to angled fascia with screws through backs-Lower portion of letter returns below building fascia extends 8” past bottom of fascia

EX3EX1

EX2

EX4EX5

EX7

EX6

EX8

SA-25

NO FIREARMSALLOWED

NO SMOKING

A VALID CONCEALED CARRY PERMIT DOES NOT AUTHORIZE YOU TO CARRY A CONCEALED WEAPON

ONTO THESE PREMISES

TO REPORT VIOLATIONS CALL

1-866-559-OHIO (6446)IN ACCORDANCE WITH CHAPTER #3794

OF THE OHIO REVISED CODE.

PURSUANT TO THE OHIO REVISED CODE, NO PERSON SHALL POSSESS, HAVE UNDER THE PERSON’S CONTROL, CONVEY OR ATTEMPT TO CONVEY A DEADLY

WEAPON OR DANGEROUS ORDINANCE ONTO THESE PREMISES.

NO PUBLIC RESTROOMSNO FOOD OR DRINK INSIDE

Hours of operation:Open Monday - Friday8:00 a.m. to 5:00 p.m.

Closed Holidays EMPLOYEES ONLYVISITORS PLEASE USE MAIN ENTRANCE

EX9

Page 14: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 14

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

EX1

COTA Logo SCALE: 1/2” = 1’-0”

Letter -Exploded viewSCALE: 1/2” = 1’-0”

1

3

Section View, for letter mountingSCALE: 1/2” = 1’-0”2

1'-10

"1'-

2"

EXISTING STRUCTURE TO REMAIN

EXISTING FACADE

6'-5 3

/8"

CURTAIN WALL SYSTEM

EXISTING STEELInternal baffle to support LED lightingTranslucent acrylic faces, to illuminate red and appear red during daytime

LED light modules spaced to provide even face illumination

Screws through letter backs attach letter forms flush to angled fascia

Secondary power penetration into building fascia, remote mounted power supplies

White letter returns with white trim cap

White letter returns, .040 Aluminum, welded and ground smooth

White trim cap

Acrylic lens

FrontSide

9º ± Slope

Weep holes with TP to prevent light leaks

30”18”

23 3/4”6 1/4”

16”

16”

4 1/2”

12’-3 1/2” OAL

15 1/8”

15 1/8”

16”

42 3/8” OAH

30” C

ap H

eigh

t

Letter back, .125” Aluminum

Extended returns at lower section

Power penetration

Screw mounting holes

-FONT: COTA Logo vector artwork as provided by COTA, 30” cap height-Precision cut letter forms with .060” aluminum returns, white-Welded .125” thick aluminum letter backs, white-Acrylic letter faces to illuminate strong RED color w/ white trim cap-Mounting pattern required

8”

4 1/2”

6 1/4”

4 1/2”

8”

EX1

Page 15: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 15

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

EX2

WilliamJ. LhotaBuildingDimensional Plate letters, FRONTSCALE: 1” = 1’-0” Etched vinyl Copy Example Layout

SCALE: 1” = 1’-0”2 3

-FONT: Akkurat Bold, 5 1/2” cap height-Precision cut and painted letter forms from 1/2” thick plate aluminum -Paint to match existing address numbers -Dark Bronze, VIF-Attaches to column face with blind threaded studs into pre-drilled holes and silicone adhesive-Mounting pattern required-Field verify column width before fabrication to ensure proper sizing to fit-Full size vector artwork provided by architect

-FONT: Avenir Standard 95 Black, 2 1/2” cap height-Precision computer cut and masked etched/frosted 3m vinyl letter forms-Apply on site to vestibule onto second surface of glass-Clean and prep glass for vinyl installation-Applied vinyl to be free of tears, bubbles, dust particles and straight/plumb-Field verify glass VO’s before fabrication to ensure proper sizing to fit-Full size vector artwork provided by architect-Final Copy TBD-See next page for related RGB LED down lightingThreaded studs

1/2” thick aluminum

Paint Dark Bronze

Letter Iso View

Partial Vestibule view from rendering

Partial Column view from rendering

5 1/2”

29 3/4”

5 1/2”5 1/2”

3 1/2”3 1/2”

EX3

EX2

9’-0” 4’-4 3/4”+/-

9’-4 3/4”

9’-4 3/4”

2 1/2” cap height

Page 16: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 16

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

����������

����������

�������������

������������

���������

�����������

�������

����������

��������

���

���������������

�������

�������

����������������

������

�� �������������������

�������������

������������

��������������������

��������

�������

��

�� ������� �����

1 2

3

Vestibule Reflected Ceiling PlanScale: 1/4” = 1’-0”

Vestibule Axion ViewScale: 1/4” = 1’-0”

Typ. Section, Store front topScale: 3/4” = 1’-0”

2 strips at 54” long (104” Total length)-5 adjustable mounting clips each (10 total)

4 strips at 51” long -10 adjustable mounting clips each run (20 total)-Total length of 104” (208” Total)

Calculations:208” + 104” = 312” total length of all strips312 ÷ 12 = 26’-0” total length of all strips26’ x 100 Lumens per foot = 2,600 Total Lumens

Adjustable mounting clips

GlassSide by side (2) LED light strips on adjustable mounts attached

to bottom of mullions with screws

0.4”

0.6”

0.7”

Red Strips indicate down pointing RGB LEDwall washer strips mounted to under side of

store front mullions

Remote mounted power supplies in wall cavityAccessible through surface mounted panel120v power routed to cavity by others

Low voltage secondary wiring from power supplies to lights to be enclosed in narrow, low profile surface mounted conduit

EX3

EX4EX6

Page 17: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 17

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

Typical Computer Cut Vinyl Details, Qty: 1 of each type shown -Precision computer reverse cut 3M white vinyl copy and logo-Clean glass surface and prep for vinyl application-Applied to second surface of glass free of tears, bubbles, dust, etc.-Font: Glober Bold, 1” capital height, and COTA Logo, sized as shown-Vector artwork on file-Test application required to ensure legibility

EX5

Partial Storefront view from rendering indicating EX5, EX7 and EX8 Locations-Type EX5, Bottom base line of copy to be 4” above cross mullion, and centered vertically on V.O. of glass-Type EX7, Top of copy to be 4” below cross mullion, and centered vertically on V.O. of glass-Type EX7, Spaced below Type EX7 2”

1”

1 3/4”

2 1/4” +/-

7 1/2” OAH

13” AOW

1 Vinyl copy /Relocated MessagingSizes as Shown

NO PUBLIC RESTROOMS

NO FOOD OR DRINK INSIDE

Hours of operation:Open Monday - Friday8:00 a.m. to 5:00 p.m.

Closed HolidaysEX5

EX7

EX8

1”EX8

1”6”

6”

EX7

2 Exterior Vinyl and Relocated SignageScale: NTS

Page 18: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 18

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

1 Exterior Regulatory VinylScale: 3” = 1”

1”

15” +/-”

3/4”

6”

3/4”1/2”1/2”3/4”

1/2”

1/2”1/2”1/4”1/2”

1 1/2”

1”

3/4”

1”

3/4”

6”

3/4”1/2”1/4”1/2”1/4”1/2”

3/8”1/4”3/8”1/4”3/8”

3/4”

2 Exterior Regulatory-LocationScale: NTS

EX4 EX6

NO FIREARMSALLOWED

NO SMOKING

A VALID CONCEALED CARRY PERMIT DOES NOT AUTHORIZE YOU TO CARRY A CONCEALED WEAPON

ONTO THESE PREMISES

TO REPORT VIOLATIONS CALL

1-866-559-OHIO (6446)IN ACCORDANCE WITH CHAPTER #3794

OF THE OHIO REVISED CODE.

PURSUANT TO THE OHIO REVISED CODE, NO PERSON SHALL POSSESS, HAVE UNDER THE PERSON’S CONTROL, CONVEY OR ATTEMPT TO CONVEY A

DEADLY WEAPON OR DANGEROUS ORDINANCE ONTO THESE PREMISES.

Partial view of glass wall adjacent to the Main entrance indicating EX4 Location-Bottom base line of copy to be 3” above cross mullion, and 6” away from the left vertical mullion on V.O. of glass

3”

6”

Typical Computer Cut Vinyl Details, -Precision computer reverse cut 3M white vinyl copy and logo-Clean glass surface and prep for vinyl application-Applied to second surface of glass free of tears, bubbles, dust, etc.-Custom copy and graphics as shown-Vector artwork on file-Test application required to ensure legibility

Page 19: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 19

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

1 Cut Vinyl layout EX9Sized as shown

1 3/4”

1/2”

2 Applied Vinyl, EX9, Rendering overlayScale: NTS

Partial view of north door from rendering indicating EX9 Location-Copy to be centered horizontally on V.O. of glass

EX9

7/8”

EMPLOYEES ONLYVISITORS PLEASE USE MAIN ENTRANCE

60”

Typical Computer Cut Vinyl Details, -Precision computer reverse cut 3M white vinyl copy and logo-Clean glass surface and prep for vinyl application-Applied to second surface of glass free of tears, bubbles, dust, etc.-Font: Glober Bold, 1 3/4” and 7/8” capital height-Vector artwork on file-Test application required to ensure legibility-Field Verify door width to ensure proper sizing

Page 20: COTA 33 HIGH ST. RENOVATION EXTERIOR SIGNAGE 100% ......signage for approval by Owner, prior to fabrication. Text shown on Drawings is provided for the purpose of pricing only. Final

300 Spruce St #300, Columbus, OH 43215 (614) 461-4664 PROJECT NAME

PROJECT ADDRESS

PROJECT NUMBER

DWG ISSUE DATE:SIGN TYPE:

SCALE:

FILE PATH:DRAWN BY: SH

EET: 20

REVISIONS: REVISIONS: ProofFinal ArtApproved as Noted

Approved by: _________________ ____/____/______

#1#2#3#4

#5#6

E X P E R I E N T I A L D E S I G N S T U D I O

2 634

1 507/12/19

As NotedTN / TH

Central Ohio Transit Authority33 N. High St. Lobby Renovation

33 N. HIGH ST. COLUMBUS, OH 43212

P:18088.03

Currently (4) of these cast metal plaques are attached to exterior building columns adjacent to the front steps-Remove all 4 signs and select the best 3-Refurbish the best 3 signs-Re-install the 3 refurbished signs at original locations-Location 2 will be concealed by new construction, hence only of these 3 signs will need to be refurbished and re-installed

Refurbishing to include:-Chemically remove clear coat and background paint-Remove oxidation and clean-Re-paint background color to match original color-Re-grain raised elements in same direction as original grain-Apply new heavy clear coat-Repair any mounting hardware as needed

S.A. ITEM #25 - No sitting on stairs Sign

1 3 2 4

Plaque Locations 1 and 3 Plaque Locations 2 and 4NOTE: Location 2 will be covered by new construction

SA-25