Upload
mehul-varshney
View
220
Download
0
Embed Size (px)
Citation preview
8/13/2019 CRE II -29
1/14
L -29 Diffusion Effects in catalyst:
effectiveness factor
Prof. K.K.Pant
Department of Chemical EngineeringIIT Delhi.
mailto:[email protected]:[email protected]8/13/2019 CRE II -29
2/14
2
The total rate of consumption Of A inside a pellet
Evaluated at the surface conditions
8/13/2019 CRE II -29
3/14
Internal Effectiveness Factor
As s
Actual overall rate of reaction =
Rate of reaction that would result if entire
interior surface were exposed to the externalpellet surface conditions C ,T
' "
A A A
' "
As As As
-r -r -r = = =
-r -r -r
8/13/2019 CRE II -29
4/14
4
For STRONG PORE DIFFUSION
8/13/2019 CRE II -29
5/14
Internal Effectiveness Factor
1 121
3
= coth -1
Internal effectivenessFactor, is: ranged 01
for a first-orderreaction in a spherical
catalyst pellet
8/13/2019 CRE II -29
6/14
6
8/13/2019 CRE II -29
7/14
7
8/13/2019 CRE II -29
8/14
Calculation of Catalytic Effectiveness FactorCatalytic Effectiveness Factor:
where
- Thiele Modulus
1storder reaction rate:
Spherical Pellet
Cylindrical Pellet
Slab Pellet
)313(1
Coth
DekSaR p/3
DekSaR
p/2
DekSaL p/
8/13/2019 CRE II -29
9/14
9
How can the rate of reaction be increased?
Decrease the radius of the pellet.
increase the temperature.
Increase the concentration
Increase the internal surface area
For large value of Thiele modulus, the effectiveness factor (for n>1
efffectiveness factor decrease with increase concentration at the
external surface of the pellet
8/13/2019 CRE II -29
10/14
10
For nthorder reaction
= ( 2/n+1 )
1/2
3/= R( k CASn-1/ De)
1/2
OR
2= R2kSap CASn-1/De
8/13/2019 CRE II -29
11/14
11
Uses the measured values of the rate of reaction to
determine if Internal diffusion controls the rate.
Weisz-Prater Parameter CWP2= 3( Coth -1)
2 = (observed rate/rate cal. at CAS) x (rate
calculated at CAS) / diffusion Rate)
= (-rA(obs)/ -rAs
2= -rASSapR2/De CAs = -rAS pR
2/De CAs
WeiszPrater Criterion for internal diffusion
8/13/2019 CRE II -29
12/14
12
CWP= (-rA(obs)/ -rAs )(-rASpR2/De CAS)
CWP = (-rA(obs) (pR2/De CAS)
These are measured or known terms.
if CWP > 1, Internal diffusion limits the rate.
8/13/2019 CRE II -29
13/14
Falsified Kinetics
Measurement of the apparentreaction orderand activation energy results primarily wheninternal diffusion limitations are present.
This becomes serious if the catalyst pelletshape and size between lab (apparent) andreal reactor (true) regime were Too different.
Smaller catalyst pelletreduces the diffusion
limitationhigher activation energy moretemperature sensitive
RUNAWAY REACTION CONDITIONS!!!!
8/13/2019 CRE II -29
14/14
Falsified Kinetics
With the same rate of production, reaction order
and activation energy to be measured