NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
This report contains data that are not covered by the NVLAP accreditation.
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 1 of 12
Report Number: PL06411-001A
Model: CPY250-A-xx-F-D-UL-40K-xxxx or
BXCCAxA17-Ux7xxxx
Date: 07/17/2015
Cree Racine Engineering Services Testing Laboratory
(RESTL) Photometric Testing and Evaluation
Report
Prepared For:
Christopher Strom
Cree, Inc.
9201 Washington Avenue
Racine, WI 53406
Prepared By: Approved By:
Cedric Duviols, Photometric Test Technician Christopher McLaurin, Photometric Specialist
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 2 of 12
Product Information
Manufacturer Cree, Inc.
Model Number (SKU) CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx
Serial Number PL06411-001
LED Type XTE DA1150
Product Description
Cast white painted finned metal housing, molded white plastic reflector, 1 white circuit board with multiple LEDs, clear flat micro-prismatic glass lens in cast white painted metal frame. Lens prisms down.
Driver Information (Where Applicable)
Philips LEDINTA0700C210D0
Length Width Height
15.0” 15.0” 3.0”
Sample
The following sample was submitted for evaluation
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 3 of 12
Key Photometric Data Sphere Output Goniophotometer
Luminous Flux 17760.8 17682.7 lm
Efficacy 118.12 117.74 lm/W
Correlated Color Temperature (CCT) 3941 K
Color Rendering Index (CRI) 71
R9 -18
Duv 0.00015268
S/P Ratio* 1.45
Sphere Goniophotometer
Electrical Measurements 120V 277V 120V 277V
Input Wattage 150.36 148.16 150.18 147.96 W
Input Current 1.25 0.55 1.26 0.55 A
Input Voltage 119.96 276.94 120.02 276.96 V
Power Factor 0.998 0.972 0.996 0.973
Off-State Power 0 0 0 0 W
Total Harmonic Distortion (Voltage) 0.05 0.06 0.10 0.10 %
Total Harmonic Distortion (Amperage) 3.95 9.45 4.01 9.55 %
Note: All photometric measurements taken at 120VAC.
Luminous Intensity Distribution Goniophotometer
Max Candela 7259.2 Cd
Angle of Max Candela (Horizontal) 0 ˚
Angle of Max Candela (Vertical) 0 ˚
Key Test Parameters Sphere Output Goniophotometer
Stabilization Time 73 48 min
Total Operating Time (Stabilization + Test) 78 68 min
Ambient Temperature 24.8 24.8 ˚C
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 4 of 12
Chromaticity Coordinates
x y u v u’ v’ Duv
0.3832 0.3788 0.2261 0.3353 0.2261 0.5029 0.00015268
Color Rendering Index Details
Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14
71 70 75 79 72 69 65 79 57 -18 41 69 40 70 88
Chromaticity Diagram
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 5 of 12
Spectral Distribution
λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm
360 0.000805 530 0.237369 700 0.041840
370 0.001030 540 0.260936 710 0.031741
380 0.000680 550 0.276705 720 0.024087
390 0.000439 560 0.289188 730 0.018056
400 0.001015 570 0.299797 740 0.013440
410 0.010058 580 0.306713 750 0.009997
420 0.055883 590 0.304858 760 0.007452
430 0.170442 600 0.293474 770 0.005487
440 0.342275 610 0.273778 780 0.004178
450 0.258223 620 0.245988 790 0.003078
460 0.090105 630 0.214258 800 0.002263
470 0.036111 640 0.180285 810 0.001650
480 0.024057 650 0.147780 820 0.001139
490 0.032501 660 0.118853 830 0.000917
500 0.071760 670 0.092916
510 0.134623 680 0.071683
520 0.196244 690 0.054999
Dominant Wavelength 579 nm
Peak Wavelength 443 nm
Spectral Power Distribution (W/nm)
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
Rad
ian
t Fl
ux
(W)
Wavelength (nm)
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 6 of 12
Zonal Lumen Summary
Zone Lumens % of Total Zone Lumens % of Total
0-5 172.9 1.0% 90-95 0.0 0.0%
5-10 512.9 2.9% 95-100 0.0 0.0%
10-15 835.8 4.7% 100-105 0.0 0.0%
15-20 1,133.9 6.4% 105-110 0.0 0.0%
20-25 1,394.0 7.9% 110-115 0.0 0.0%
25-30 1,606.4 9.1% 115-120 0.0 0.0%
30-35 1,755.3 9.9% 120-125 0.0 0.0%
35-40 1,815.5 10.3% 125-130 0.0 0.0%
40-45 1,784.1 10.1% 130-135 0.0 0.0%
45-50 1,668.6 9.4% 135-140 0.0 0.0%
50-55 1,472.9 8.3% 140-145 0.0 0.0%
55-60 1,206.4 6.8% 145-150 0.0 0.0%
60-65 904.3 5.1% 150-155 0.0 0.0%
65-70 626.1 3.5% 155-160 0.0 0.0%
70-75 402.6 2.3% 160-165 0.0 0.0%
75-80 236.8 1.3% 165-170 0.0 0.0%
80-85 119.2 0.7% 170-175 0.0 0.0%
85-90 34.9 0.2% 175-180 0.0 0.0%
Total 17682.2 lm 100%
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 7 of 12
Candela Plot Illuminance Plot
Roadway Utilization Roadway Summary Lumens % Lamp
Cutoff Classification FULL CUTOFF
Distribution Type VS
Downward Street Side 8,842.3 50%
Downward House Side 8,842.3 50%
Downward Total 17,684.6 100%
Upward Street Side 0 0%
Upward House Side 0 0%
Upward Total 0 0%
Total Lumens 17,684.6 100%
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 8 of 12
Luminaire Classification System
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 9 of 12
Candela Tabulations
0 22.5 45 67.5 90 22.5 0 22.5 45 67.5 90
0 7259 7259 7259 7259 7259 92.5 0 0 0 0 0
2.5 7233 7224 7239 7244 7256 95 0 0 0 0 0
5 7220 7205 7218 7228 7236 97.5 0 0 0 0 0
7.5 7154 7159 7178 7201 7223 100 0 0 0 0 0
10 7094 7106 7099 7140 7168 102.5 0 0 0 0 0
12.5 7029 7048 7032 7063 7086 105 0 0 0 0 0
15 6968 6989 6972 6979 7005 107.5 0 0 0 0 0
17.5 6889 6908 6882 6869 6910 110 0 0 0 0 0
20 6770 6790 6777 6762 6798 112.5 0 0 0 0 0
22.5 6632 6652 6652 6654 6685 115 0 0 0 0 0
25 6484 6507 6525 6521 6546 117.5 0 0 0 0 0
27.5 6310 6341 6374 6364 6390 120 0 0 0 0 0
30 6125 6163 6199 6194 6190 122.5 0 0 0 0 0
32.5 5904 5960 6019 5986 5958 125 0 0 0 0 0
35 5649 5726 5802 5747 5687 127.5 0 0 0 0 0
37.5 5334 5442 5550 5467 5377 130 0 0 0 0 0
40 5026 5117 5263 5156 5054 132.5 0 0 0 0 0
42.5 4724 4800 4947 4826 4743 135 0 0 0 0 0
45 4398 4487 4590 4495 4422 137.5 0 0 0 0 0
47.5 4040 4151 4185 4155 4070 140 0 0 0 0 0
50 3688 3775 3794 3796 3718 142.5 0 0 0 0 0
52.5 3327 3399 3407 3426 3373 145 0 0 0 0 0
55 2930 3012 3007 3046 3002 147.5 0 0 0 0 0
57.5 2549 2614 2604 2649 2619 150 0 0 0 0 0
60 2182 2225 2205 2248 2227 152.5 0 0 0 0 0
62.5 1834 1861 1837 1875 1859 155 0 0 0 0 0
65 1509 1528 1505 1535 1523 157.5 0 0 0 0 0
67.5 1216 1234 1214 1238 1235 160 0 0 0 0 0
70 964 980 966 982 984 162.5 0 0 0 0 0
72.5 748 764 758 769 769 165 0 0 0 0 0
75 566 583 585 592 585 167.5 0 0 0 0 0
77.5 418 435 441 445 435 170 0 0 0 0 0
80 298 312 320 321 310 172.5 0 0 0 0 0
82.5 203 214 221 220 210 175 0 0 0 0 0
85 125 132 136 136 128 177.5 0 0 0 0 0
87.5 58 61 62 62 59 180 0 0 0 0 0
90 0 0 0 0 0
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 10 of 12
Integrating Sphere Equipment List
Description Manufacturer Model Serial Number
2M Sphere Everfine 2M 1004156T
CCD Array Spectrometer Labsphere MC-9801 98010360
Programmable AC Source Adaptive FC200 2280220
Power Analyzer Yokogawa WT310 C2QC04045V
Goniophotometer Equipment List
Description Manufacturer Model Serial Number
AC Power Source Chroma 61602 616020002300
Type C Goniophotometer LSI / UL 6440T 6440PN2028
Spectroradiometer Gooch & Housego 770VIS/NIR 12415212
Power Meter Yokogawa WT210 91M945458
Test Methods Used:
Title Description
ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment
CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources
CIE Pub. 15:2004 Colorimetry
IES LM-58:1994 Spectroradiometric Measurements
IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance
IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products
Reference Standard Used:
Equipment Description
2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119
Type C Goniophotometer and Spectrometer
Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 11 of 12
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.
The results contained in this report pertain only to the tested sample.
This report shall not be reproduced, except in full, without written approval of the CESTL.
Items marked with a single asterisk are not covered by the NVLAP accreditation.
In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.
** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as
“Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the
first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are
performed using a Type C goniophotometer.
The integrating sphere information in the equipment list, report items marked with **, or results specifically
identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the
subcontracted laboratory when subcontracting is indicated on the cover page.
Additional Comments:
The photos below are intended to show the orientation and fixturing/set-up of the units under test. These
are critical to understanding the results of the test given the sensitivity of many products and
measurement systems to orientation and set-up considerations, and also for reproducing the conditions of
the test.
Goniophotometer Integrating Sphere
NVLAP Lab Code 500089-0
Test Report Number: PL06411-001A RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 12 of 12
Document Revision History:
Each subsequent revision of this report replaces the preceding report.
Date Rev DCN # Change at the time of this test By Approval
07/17/15 A DMS Origination C. Duviols C. McLaurin