On-site calibration maximizes
power plant availabilityEndesa Generacin saves time and money with Endress+Hauser
calibration services
Endesa Generacin is the leading
power generation company in Spain,
with an output of 35,230 GWh and
a Spanish market share of 33.4%
in total ordinary regime generation
(generation of electricity through
traditional non-renewable sources
and large hydro-electric plants -
data from the rst half of 2011) .
Endesa Generacin owns 25 power
plants in Spain (nine in the Iberian
Peninsula, ve in the Balearics, nine
in the Canary Islands and another
two in Ceuta and Melilla).
Endesa Generacins
requirements:
Ensure the accurate
and reliable fuel
consumption
measurementin
power generation
engines.
Proposeasolutionto
perform calibration
as quickly as
possible.
Endesa Generacins main objective is to optimizethe companys competitive position by producingelectricity at minimum cost. They achieve thisby maximizing the availability of equipment andfacilities, and ensuring the safety of people andassets, while respecting the natural environment.
To measure the fuel (diesel and fuel oil) consumption of
the engines that generate power, Endesa Generacin putsits trust in the quality and accuracy of Endress+HauserPromass flowmeters. This measurement is the basis forthe calculation of greenhouse gases emissions.
To ensure optimum operation, flowmeter calibration has to beperformed as quickly as possible, and only when gensets arestopped. Endress+Hauser allows Endesa Generacin to meetthis requirement by providing on-site calibration services.
8/22/2019 CS01299H Endesa en OK WEB - Endress Hausser
2/2
CS01299H/29/EN/01.12
PF/INDD CS5.5
Mobile rig enables quick owmeter calibration on site
Our solution
Calibration of a flowmeterinvolves disassembling it,
packaging the device andsending it to a specialistlaboratory. During the time
the device is unavailable, asubstitute flowmeter needs tobe mounted into the process.
With 58 Coriolis flowmeterssited in different diesel plantsin Ceuta and Melilla, and alsoacross the Balearic and Canary
islands (Menorca, Tenerife,Lanzarote and el Hierro),
periodical calibration couldrapidly turn into a nightmare
for Endesa Generacin.
Endress+Hauser proposed aflexible, mobile solution thatenables flowmeter calibrationto be performed on-site.This not only simplifies but alsoshortens the calibration process.
The mobile calibration setis shipped to the requiredlocation. On site, theEndress+Hauser servicetechnician performs
calibration according to theEndress+Hauser qualitystandards as written in theStandard Operating Procedures(SOPs) and delivers the
appropriate certicates.
1
Scheduling If needed, we visit the facility to dene the scope of the service
and specic details. Our service coordinator gets in touch in good
time to schedule a date according to the customers needs andplant availability.
2 Flexible, mobile calibration All the hi-tech equipment is mounted and packaged in three ightcases. The mobile calibration set is ready for shipment by air orsea to the required location.
3 Execution On site, our qualied service technicians perform the calibrationof owmeters according to our Standard Operating Procedures. In
Ceuta, 11 Promass Coriolis owmeters were calibrated within three
working days.
4 Completion For each calibrated device, we deliver a Certicate of Calibration ofUUT (Unit Under Test) as well as the master meters SCS certicate.
Typical action plan when a calibration contract is signed
Instruments International
Endress+Hauser
Instruments International AG
Kgenstrasse 2
4153 Reinach
Switzerland
Tel. +41 61 715 81 00
Fax +41 61 715 25 00
http://www.endress.com
Other locations
Please visit:
www.endress.com/worldwide
At Endesa Central Diesel de Ceuta,, we need to periodicallycalibrate11 fowmeters.We thought that we would haveto disassemble them and send them for calibration to theEndress+Hauser laboratory with consequent loss of time. As we hadonly one substitute owmeter, the calibration process would have
lasted several months. Thanks to the new mobile calibration ow
rig, the work was executed on site in just three days.
Germn Canosa Murcia
Electrical Maintenance
Technician, I&C
Endesa Central Diesel
de Ceuta