CS5226 2002 Hardware Tuning. Xiaofang Zhou School of Computing, NUS Office: S16-08-20 Email: [email protected] URL: www.itee.uq.edu.au/~zxf. Outline. Part 1: Tuning the storage subsystem RAID storage system Choosing a proper RAID level Part 2: Enhancing the hardware configuration. - PowerPoint PPT Presentation
Citation preview
CS5226 2002
Hardware Tuning
Xiaofang ZhouSchool of Computing, NUS
Office: S16-08-20Email: [email protected]: www.itee.uq.edu.au/~zxf
2
Outline
Part 1: Tuning the storage subsystem RAID storage system Choosing a proper RAID level
Part 2: Enhancing the hardware configuration
3
Modern Storage Subsystem
More than just a disk Disks, or disk arrays Connections between disks and
processors Software to manage and config.
devices A logical volume for multiple devices A file system to manage data layout
4
RAID Storage System Redundant Array of Inexpensive
Disks Combine multiple small, inexpensive
disk drives into a group to yield performance exceeding that of one large, more expensive drive
Appear to the computer as a single virtual drive
Support fault-tolerant by redundantly storing information in various ways
5
Data Striping
Disk 2 Disk 3 Disk 4 Disk 5 Disk 6Disk 1
1 2 3 4 5 6 7 8 9 10 11 …
File blocks (e.g., 8KB per block)
Stripe unit: blocks 1-6, 7-12, …
6
Parity Check - Classical An extra bit added to a byte to reveal
errors in storage or transmission Even (odd) parity means that the parity
bit is set so that there are an even (odd) number of one bits in the word, including the parity bit
A single parity bit can only reveal single bit errors since if an even number of bits are wrong then the parity bit will not change
It is not possible to tell which bit is wrong
7
Parity Check - Checksum A computed value based on the content
of a block of data Transmitted or stored along with the data to
detect data corruption Recomputed at the receiver end to compare with
the one received Detects all errors with old bits of errors, and most
errors with event number of bits It is computed by summing the bytes of the
data block ignoring overflow Other parity check methods, such as
Hamming Code, corrects errors
8
RAID Types Five types of array architectures, RAID 1 ~
5 Different disk fault-tolerance Different trade-offs in features and performance
A non-redundant array of disk drives if often referred to RAID 0
Only RAID 1, 3 and 5 are commonly used RAID 2 and 4 do not offer any significant
advantages over these other types Certain combination is possible (10, 35 etc)
RAID 10 = RAID 1 + RAID 0
9
RAID 0 - Striping No redundancy
No fault tolerance High I/O performance
Parallel I/O
10
RAID 1 – Mirroring Provide good fault tolerance
Works ok if one disk in a pair is down One write = a physical write on each disk One read = either read both or read the less busy one
Could double the read rate
11
RAID 3 - Parallel Array with Parity Fast read/write
12
RAID 5 – Parity Checking For error correction, rather than full
redundancy Each stripe unit has an extra parity stripe
Parity stripes are distributed
13
RAID 5 Read/Write Read: parallel stripes read from multiple
disks Good performance
Write: 2 reads + 2 writes Read old data stripe; read parity stripe (2 reads) XOR old data stripe with replacing one. Take result of XOR and XOR with parity stripe. Write new data stripe and new parity stripe (2
writes).
14
RAID 10 – Striped Mirroring RAID 10 = Striping + mirroring
An striped array of RAID 1 arrays High performance of RAID 0, and high tolerance of
RAID 1 (at the cots of doubling disks)
.. More information about RAID disks at http://www.acnc.com/04_01_05.html
15
Comparing RAID LevelsRAID 0 RAID 1 RAID 5 RADI 10
Read High 2X High High
Write High 1X Medium High
Fault tolerance
No Yes Yes Yes
Disk utilisation
High Low High Low
Key problems
All data lost when one disk fails
Use twice disk space
Lower throughput with disk failure
Very expensive, not scalable
Key advantages
High I/O performance
Very high I/O performance
A good overall balance
High reliability with good performance
16
What RAID Provides Fault tolerance
It does not prevent disk drive failures It enables real-time data recovery
High I/O performance Mass data capacity Configuration flexibility Lower protected storage costs Easy maintenance
17
Hardware vs. Software RAID Software RAID
Software RAID: run on the server’s CPU Directly dependent on server CPU performance and
load Occupies host system memory and CPU operation,
degrading server performance Hardware RAID
Hardware RAID: run on the RAID controller’s CPU Does not occupy any host system memory. Is not
operating system dependent Host CPU can execute applications while the array
adapter's processor simultaneously executes array functions: true hardware multi-tasking
18
RAID Levels - Data
Settings:accounts( number, branchnum, balance);create clustered index c on accounts(number);
100000 rows Cold Buffer Dual Xeon (550MHz,512Kb), 1Gb RAM,
Internal RAID controller from Adaptec (80Mb), 4x18Gb drives (10000RPM), Windows 2000.
19
RAID Levels - Transactions
No Concurrent Transactions: Read Intensive: select avg(balance) from accounts;
Write Intensive, e.g. typical insert:insert into accounts values (690466,6840,2272.76);
Writes are uniformly distributed.
20
RAID Levels SQL Server7 on
Windows 2000 (SoftRAID means striping/parity at host)
Read-Intensive: Using multiple disks
(RAID0, RAID 10, RAID5) increases throughput significantly.
Write-Intensive: Without cache, RAID 5
suffers. With cache, it is ok.
Write-Intensive
0
40
80
120
160
Soft-RAID5
RAID5 RAID0 RAID10 RAID1 SingleDisk
Th
rou
gh
pu
t (t
up
les/
sec)
Read-Intensive
0
20000
40000
60000
80000
Soft-RAID5
RAID5 RAID0 RAID10 RAID1 SingleDisk
Th
rou
gh
pu
t (t
up
les/
sec)
21
Which RAID Level to Use? Log File
RAID 1 is appropriate Fault tolerance with high write throughput. Writes are
synchronous and sequential. No benefits in striping. Temporary Files
RAID 0 is appropriate. No fault tolerance. High throughput.
Data and Index Files RAID 5 is best suited for read intensive apps or
if the RAID controller cache is effective enough. RAID 10 is best suited for write intensive apps.
22
Controller Prefecthing No, Write-back Yes Read-ahead:
Prefetching at the disk controller level. No information on access pattern. Better to let database management system
do it. Write-back vs. write through:
Write back: transfer terminated as soon as data is written to cache.
Batteries to guarantee write back in case of power failure
Write through: transfer terminated as soon as data is written to disk.
23
SCSI Controller Cache - Data
Settings:employees(ssnum, name, lat, long, hundreds1,hundreds2);
create clustered index c on employees(hundreds2);
Employees table partitioned over two disks; Log on a separate disk; same controller (same channel).
200 000 rows per table Database buffer size limited to 400 Mb. Dual Xeon (550MHz,512Kb), 1Gb RAM, Internal RAID
controller from Adaptec (80Mb), 4x18Gb drives (10000RPM), Windows 2000.
24
SCSI (not disk) Controller Cache - Transactions
No Concurrent Transactions:update employees set lat = long, long = lat where hundreds2 = ?;
cache friendly: update of 20,000 rows (~90Mb) cache unfriendly: update of 200,000 rows (~900Mb)
25
SCSI Controller Cache SQL Server 7 on Windows
2000. Adaptec ServerRaid
controller: 80 Mb RAM Write-back mode
Updates Controller cache
increases throughput whether operation is cache friendly or not.
Efficient replacement policy!
2 Disks - Cache Size 80Mb
0
500
1000
1500
2000
cache friendly (90Mb) cache unfriendly (900Mb)
Th
rou
gh
pu
t (t
up
les
/se
c)
no cache
cache
26
Enhancing Hardware Config. Add memory
Cheapest option to get a better performance
Can be used to enlarge DB buffer pool Better hit ratio If used for enlarge OS buffer (as disk
cache), it benefits but to other apps as well Add disks Add processors
27
Add Disks Larger disk ≠better performance
Bottleneck is disk bandwidth Add disks for
A dedicated disk for the log Switch RAID5 to RAID10 for update-intensive
apps Move secondary indexes to another disk for
write-intensive apps Partition read-intensive tables across many
disks Consider intelligent disk systems
Automatics replication and load balancing
28
Add Processors Function parallelism
Use different processors for different tasks GUI, Query Optimisation, TT&CC, different types
of apps, different users Operation pipelines:
E.g., scan, sort, select, join…
Easy for RO apps, hard for update apps Data partition parallelism
Partition data, thus the operation on the data
29
Parallel Join Processing Algorithm: decompose and processing in
parallel T = R S Let f: A (1..n) (a hash function) R = i=1..n Ri, Ri = {r R | f(r.A) = i} S = i=1..n Si, Si = {s S | f(s.A) = i} T = i=1..n Ri Si
Issues However, data distribution, task decomposition
and load balancing are non-trivial
A
A
30
Parallelism
Some tasks are easier to be parallelised E.g., scan, join, sum, min
Some tasks are not so easy E.g., sorting, avg, nested-queries
31
Parallel DB Architectures Shared memory
Tightly coupled, easy-to-use, but not scalable (bottlenecks when accessing shared memory and disks)
Shared nothing A distributed with message-passing as the
only communication mechanism Highly scalable Difficult for load distribution and balancing
Shared disk A trade-off, but towards the shared-memory
end
32
Summary
In this module, we have covered: The storage subsystem
RAID: what are they and which one to use?
Memory, disks and processors When to add what?