CSA.31L LTE Device Active Mode Testing – TISOCT 2018 / WP-18-10-20
Taoglas makes no warranties based on the accuracy or completeness of the contents of this document and
reserves the right to make changes to specifi cations and product descriptions at any time without notice.
Taoglas reserves all rights to this document and the information contained herein. Reproduction, use or
disclosure to third parties without express permission is strictly prohibited. Copyright © Taoglas Ltd
Service Name CSA.31L LTE Device Active Mode Testing – TIS
Deliverables TRP Performance Report
Duration 2 Days
Items A Test in 3D anechoic chamber – Full TRP analysis
B If fail consult with Noise Control Division
Variant CSA.31L.1 LTE Device Active Mode Testing – TIS (North America)
CSA.31L.2 LTE With Fall Back Device Active Mode Testing – TIS (North America)
CSA.31L.3 LTE Device Active Mode Testing – TIS (Global)
WP-18-10-20 02
What is the problem or concern we are addressing? Post-integration verification of device Total Isotropic Sensitivity (TIS) performance. TIS is dependent on both antenna
performance and system design, in particular device emissions control. Many of the network operators in North America
have specific tests and metrics for radiated performance on transmit (TRP) and receive (TIS). These tests enforce a
minimum level of performance on the wireless product. This is done to ensure end customer use-experience expectations
are met, thus protecting the carrier’s network brand.
Testing these performance parameters early in the design cycle can reduce risk of certification failure and costly design
and tooling changes late in the design cycle. The best way to test these parameters is through completing the real testing
in a real chamber. The roll-out of LTE networks has introduced a number of new frequency bands dedicated to LTE, and
the re-use of other spectrum for LTE. Several operators own exclusive frequency bands—thus heightening the need to
select a network operator during the design phase. Taoglas will test for a particular carrier, according to the table below.
LTE-only devices will undergo testing in the carrier’s LTE bands. LTE devices which support fallback to another technology
(e.g., CDMA or UMTS) will undergo testing in the carrier’s LTE bands plus the identified fallback bands.
Sensitive cellular radio receivers can be subject to inband interference, commonly called self-jamming, self-interference,
or self-quieting. This type of performance degradation occurs when low-level emissions, usually unrelated to the cellular
radio, fall onto the same frequency on which the radio is receiving data. These emissions compete with the received signal
to be heard, requiring the received signal to be much more powerful to be heard than for a “quiet” design. Even devices
which pass FCC or CE-mark testing can fall victim to this type of performance failure, making early testing a necessity.
Carrier LTE Bands Fallback Bands Fallback TechnologyAT&T E-UTRA Bands 2, 4, 5, & 17 UTRA Bands 2, 5 WCDMA (3G)
Verizon E-UTRA Bands 4 and 13 Cellular 850 and PCS1900 CDMA 1xRTT
T-Mobile E-UTRA Bands 2 and 4 UTRA Bands 2, 4 WCDMA (3G)
03WP-18-10-20
The Processes
Part 1 • Taoglas will setup your device in our chamber and power the device as per your instructions.
If the device is intended to be used on a person, a phantom will be used.
• A base station emulator will be used to establish a call or test-mode connection with the device.
• Taoglas’ automated test system will perform the TRP tests at the high, middle,
and low channels of the appropriate bands.
• Taoglas will complete the test report detailing the setup and results.
What does Taoglas need? In all cases Taoglas will require the following:
• Two (2) complete devices, with all the bits and pieces. The devices need to be functional enough
to enable the cellular modem and enable AT command access to the modem. The devices should
be built-up as much as possible, the closer to the final assembly the more accurate the results.
Batteries, displays, and metallic sub-assemblies will impact the test results and should be included.
• One complete set of any support devices such as spare battery packs, battery charger,
interface cables, etc.
• Instructions on how to connect the device, power on the device, and connect to the AT
command interface. If the battery will need to be charged or replaced, include instructions on how
to do so. Taoglas will need access to the SIM card, or for an embedded SIM, a 3GPP test profile
configured on the SIM.
Taoglas will need a method to configure the modem’s LTE receive antenna selection. This could be AT command access
and documenting the appropriate AT commands, or a selection through the device’s user interface. Taoglas cannot start TIS
testing without these details.
Part 2 Taoglas engineering in consultation with the customer on the final report will determine if the
measured performance factors are sufficient for the product to meet it’s performance and certification
requirements. If the TIS performance is not acceptable, Taoglas sales and Noise Control Division
engineering can engage in a design certification readiness review, an ISA.20.
Deliverables Taoglas will compile a report on the TIS measurements, including:
• Device test setup picture.
• Primary and Secondary TIS values for low, middle, and high channels in the designated bands.
04WP-18-10-20
Any unauthorized use, reproduction, dissemination, distribution or other disclosure of the contents is strictly prohibited.
All copyrights, trademarks and any other intellectual property rights related are owned by Taoglas Group Holding Limited.
Enniscorthy, Ireland (HQ) Unit 5, Kilcannon Business Park, Old Dublin Road
Enniscorthy, Co. Wexford, Y21 XW56, Ireland +353 53 9169500 | [email protected]
San Diego, USA 8525 Camino Santa Fe, Suite A & B, San Diego, CA 92121, United States
+1 858 450 0888 | [email protected]
Taoyuan, Taiwan No.2-2 Ln. 66, ZhongShan 1st Rd.,
Bade City, Taoyuan City 33454, Taiwan (R.O.C.) +886 3 3681223 | [email protected]
Shenzhen, China Unit 509, Neptune Building, Lanxiang 1st Street,
Nanshan District, Shenzhen 518067, China +86 755 86538292 | [email protected]
Dublin, Ireland DCU Alpha, Innovation Campus,
Old Finglas Road, Glasnevin, Dublin 11, Ireland [email protected]
Minneapolis, USA 15 S. 5th St. Suite 150,
Minneapolis, MN 55402, United States +1 858 450 0888 | [email protected]
Tainan, Taiwan 4F.-2, No.15, Guoji Road, Xinshi District,
Tainan City 744, Taiwan (R.O.C.) +886 3 3681223 | [email protected]
Munich, Germany Erika-Mann-Straße 25, Second Floor
80636 München, Germany +49 89 3803 7426 | [email protected]
www.taoglas.com