15
manufacturing access Control since 1985 Improvements and built-in features: Centaur improvements: • Automatically e-mail scheduled reports • Card Usage/Card Counter options (use a card up to 255 times on a door) • Alarm integration: arming/disarming an alarm panel on dual badge (key switch input) Visitor Management Centaur Visitor Management will allow you to se- curely control the comings and goings of all visitors. Parking Management The Centaur Parking Management allows you to quickly see how many parking places are used, by which user and how many parking spaces are available in real time. Locator Monitor the location (inside/outside) of each card holder in real-time. View/Print reports with a click of a button. Obtain detailed card holder information with a double-click of the mouse button. Excellent for muster-point applications. Print or e-mail reports of your activities Track the accesses of a specific employee, verify who accessed a specific door at a precise date and time or calculate how many hours of overtime you will pay. Centaur report wizard allows you to create your own reports easily. Live Interactive Floor Plans • Create or import up to 512 floor plans • Full library of icons (or create your own) • Event-based trigger-actions Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format. In Constant Evolution to fulfill your needs in access control New Version 5.1 New features in CeNTAUr V ersion 5.1: Guard Tour Feature Live interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports. Asset Management Feature Why buy something that you already have? Keep track of your assets and save time and money. Find quickly who is in possession of your assets. A report can be generated and sent automatically via email. Biometric Integration Centaur is a powerful solution for areas requiring enhanced security by authenticating fingerprints. Capturing, managing and transferring biometric data is now effortless with world-renowned fingerprint readers such as CDVI’s DGID/W/US, L-1 (model 4G), Sagem and more. CeNTAUr 5.1 now supports the following DVr manufacturers: • Capture • Dahua • Dedicated Micros • Digiop • Digital WatchDog • Eneo • Everfocus • HIK Vision • Infinova • Microcom • Milestone • NUUO • Samsung • Sphere • ViewGate • Vivotek IP Camera • Vivotek

CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

Programmable outPuts

reader 1 reader 2out 1(Default: Green LED)

out 3(Default: Green LED)

out 2(Default: Red LED)

out 4(Default: Red LED)

out 5(Default: Buzzer)

out 6(Default: Buzzer)

Zone inPuts

Without atZ (Zone doubling) With atZ (Zone doubling)Z1Default:Contact door 1

Z2

Z3Default:REX door 1

Z4

Z5 Z6

Z7 Z8

Z9Default:Contact door 2

Z10

Z11Default:REX door 2

Z12

Z13 Z14

Z15 Z16

relaysRelay 1(Onboard)

Relay 2(Onboard)

adding one relay expansion adding a second relay expansion

Relay 3 Relay 10

Relay 4 Relay 11

Relay 5 Relay 12

Relay 6 Relay 13

Relay 7 Relay 14

Relay 8 Relay 15

Relay 9 Relay 16

c d v i . c a

CT-V900-A Door HArDwAre

manufacturing access Control since 1985

Improvements and built-in features:Centaur improvements:• Automaticallye-mailscheduledreports

• CardUsage/CardCounteroptions (useacardupto255timesonadoor)

• Alarmintegration:arming/disarmingan alarmpanelondualbadge(keyswitchinput)

Visitor ManagementCentaurVisitorManagementwillallowyoutose-curelycontrolthecomingsandgoingsofallvisitors.

Parking ManagementTheCentaurParkingManagementallowsyoutoquicklyseehowmanyparkingplacesareused,bywhichuserandhowmanyparkingspacesareavailableinrealtime.

LocatorMonitorthelocation(inside/outside)ofeachcardholderinreal-time.View/Printreportswithaclickofabutton.Obtaindetailedcardholderinformationwithadouble-clickofthemousebutton.Excellentformuster-pointapplications.

Print or e-mail reports of your activitiesTracktheaccessesofaspecificemployee,verifywhoaccessedaspecificdoorataprecisedateandtimeorcalculatehowmanyhoursofovertimeyouwillpay.Centaurreportwizardallowsyoutocreateyourownreportseasily.

Live Interactive Floor Plans • Createorimportupto512floorplans• Fulllibraryoficons(orcreateyourown)• Event-basedtrigger-actions

Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format.

In Constant Evolution

to fulfill your needs

in access control

New Version 5.1

New features in CeNTAUr Version 5.1:Guard Tour FeatureLive interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports.

Asset Management FeatureWhybuysomethingthatyoualreadyhave?Keeptrackofyourassetsandsavetimeandmoney.Findquicklywhoisinpossessionofyourassets.Areportcanbegeneratedandsentautomaticallyviaemail.

Biometric IntegrationCentaurisapowerfulsolutionforareasrequiringenhancedsecuritybyauthenticatingfingerprints.Capturing,managingandtransferringbiometricdataisnoweffortlesswithworld-renownedfingerprintreaderssuchasCDVI’sDGID/W/US,L-1(model4G),Sagemandmore.

CeNTAUr 5.1 now supports the followingDVr manufacturers:

• Capture• Dahua• Dedicated Micros• Digiop• Digital WatchDog• Eneo• Everfocus• HIK Vision• Infinova• Microcom• Milestone• NUUO• Samsung• Sphere• ViewGate• Vivotek IP Camera• Vivotek

Page 2: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

Access level 1: __________________________

Schedule 1*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

Access level 2: __________________________

Schedule 2*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

Access level 3: __________________________

Schedule 3*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

Access level 4: __________________________

Schedule 4*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

aCCess leVels and sChedules deFinition

Card user name Card numberFamily : Number aCCess leVel

1: : 2: : 3: : 4: : 5: : 6: : 7: : 8: : 9: : 10: : 11: : 12: : 13: : 14: : 15: : 16: : 17: : 18: : 19: : 20: :

* HH:MM to HH:MM

Key FeATUres IN VersIoN 5.1• Guard Tour features: Allows check point validation using card readers, input points (Motion sensors, key

switches, or push buttons) or data collectors.• Asset Management, find quickly who is in possession of your assets and for how long.• Biometrics integration (CDVI’s DGID/W/US, L-1 model 4G, Sagem and more)• Alarm integration: Arm/disarm an alarm system with a double card swipe• Card Usage/Card Counter options (use a card up to 255 times on a door) • All reports including Time & Attendance reports can be sent automatically by e-mail• Unassign card on period of inactivity (up to 365 days)• New DVR support (see the list on the front page)• Import/export users, cards and all related objects• Manually control doors from event window• New controller standalone functionality a. Activate relay on access granted, extended access (Disabled person) b. Activate relay on door forced open status c. Activate relay on door open too long status d. Relay follow input (keep light open on movement) e. Maintain door locked/unlocked on valid card (classroom application)• Play waves on alarm from the administration console• Additional filters in Locator• Now support DNS in the controller properties• Added French support in WavePlayer• Parking group: Reset parking count• SAP import for users/cards• When User/Visitor status is changed, it is now reflected on the cards• Support TELACCESS• Support DGLM magnetic stripe reader• Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management dialog (Add, Delete, Modify and etc.). e. New usage billing report f. New access report type (access granted only) g. New option in Tracker Preferences (show valid users only)

INTEGRATED ACCESS CONTROL

sITe CoNFIgUrATIoN QUICK Form

imPortant --- imPortant Please note that Centaur 5.1 version is compatible with Centaur 5.0 Dongles.

Firmware update of CT-V900-A will be necessary to perform new 5.1 features. See details below:R2-C3-98 - Works with Centaur 5.1 and support up to 8,190 cards

R2-G3-98 - Works with Centaur 5.1 + LCD Tracker feature and support up to 4,914 cards

Page 3: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

Project: _______________________________ Door Name:_______________________

Door contact � Surface � Flush

� Electromagnet� 24V � 12V

� Door Strike � 24V � 12V� Fail Safe � Fail Secure

REQUEST-TO-EXIT (REX)� Motion Detector� Pull Station� Push Button� Push Bar/Crash Bar

READING DEVICE (ENTRY)� Reader Technology:_______________� Keypad Technology:_______________

READING DEVICE (EXIT)� Reader Technology:_______________� Keypad Technology:_______________

� Fixed Door

Electromagnet �24V � 12V �

Door contact � Surface � Flush

Fixed Door �

DOUBLE-DOOR OPTION

door typeq Access (Most common setting)q Elevatorq Entry Anti-passback (1 CT-V900-A only, 8 readers)q Exit Anti-passback (1 CT-V900-A only, 8 readers)q Global Entry Anti-passback (multiple doors)q Global Exit Anti-passback (multiple doors)q Parking Global Entry Anti-passbackq Parking Global Exit Anti-passbackq Two Card Rule

optionsq Unlock on late open (Ignore the unlock schedule until the first person arrives) q Time and attendanceq Sign-Out reader (Visitor)

unlock schedule (optional)Schedule time (HH:MM): __________________

Days: S M T W T F S qqqqqqq

interlock (man-trap)With door (input): _________________________

door Programming

CT-V900-A Door HArDwAre

liteCs-aC-lite

standardCs-aC-std

ProfessionalCs-aC-Pro*

enterpriseCs-aC-ent*

Free**

starter PaCk

sites 1 64 64 64 1

serial Ports 1 1 1 4 4

dial up connection Yes Yes Yes Yes Yes

tCP/iP connection Yes Yes Yes Yes Yes

Cards 512 2,048 per site(131,072 max.)

8,196 per site(524,544 max.)

16,384 per site(1,048,576 max.) 512

Controllers 16 32 per site(2,048 max.)

64 per site(4,096 max.)

256 per site(16,384 max.) 1

doors 16 128 per site(8,192 max.)

512 per site(32,768 max.)

2048 per site(131,072 max.) 8

elevator Control - Yes Yes Yes Yes

elevator Cabs - 64 per site(4,096 max.)

128 per site(8,192 max.)

512 per site(32,768 max.) 2

Floors per cab - 64 64 64 64

Floor groups - 128 per site(8,192 max.)

128 per site(8,192 max.)

128 per site(8,192 max.) 128

dVr module - Yes Yes Yes Yes

Visitor management - Yes Yes Yes Yes

Parking management - Yes Yes Yes Yes

guard tour - Yes Yes Yes Yes

asset management - Yes Yes Yes Yes

* Comes with a workstation license New ** Free from our web site, www.cdvi.ca Security dongle not required

INTEGRATED ACCESS CONTROL Version 5.1

Workstation license (Cs-WsliC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules.

enhanced security dongle. Previous dongle not supported by Centaur V5.0 and 5.1

every Centaur edition includes a Centaur server with an administration console plusall these software modules:Pro-report with tracker: On demand, scheduled or customized reportsFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cards, include Photo-IDlocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event

Page 4: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

E-bus Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 E-bus network. (Furthest modules can be up to 1220m (4000ft) from start point)

END POINTof the RS-485 E-bus network

CT-V900-A2-Door Controller

CT-V900-A

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

CA-A480-A

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

E-bus Network Jumper settingsEOL= ON

Bias High/LowA+= HighB-= High

CA-A480-A

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

CA-A470-A

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

E-bus Network Jumper settingsEOL= ON

Bias High/LowA+= LowB-= Low

CA-A470-A

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE WITH THE CT-V900-A NO LONGER THE START POINT

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

This example depicts an existing RS-485 E-bus network with 1 CA-A470-A and 2 CA-A480-A to which we are adding a CA-A470-A after the initial installation.

In our example the END POINT, the CA-A480-A, is at 914m (3000ft) from the CT-V900-A and the new CA-A470-A module you would like to add is 30m (100ft) from the CT-V900-A.

The flexibility of the RS-485 E-bus network jumpers permits you to locate the new CA-A470-A close to the CT-V900-A by simply re-configuring jumper settings of the new START POINT and what was the start point before.

This permits you to have a 30m (100ft) cable run instead of914m (3000ft).

Addressable dipswitch

Addressable dipswitch Addressable dipswitch Addressable dipswitch

Centaur System Architecture

LCD DisplayCK-TRAK-L

(Max. 8 per CT-V900-A)

Elevator ControllerCA-A480-A

(Max. 8 per CT-V900-A)

Relay Expansion ModuleCA-A460-P

(Max. 2 per CT-V900-A)

2-Door Expansion ModuleCA-A470-A

(Max. 3 per CT-V900-A)

to other Ct-V900-a controllers

E-bus NEtwork ModulE CapaCity

to PC Centaur serverSee diagram above Furthest modules

can be up to 1220m (4000ft) away from the

CT-V900-A

Digital Video Recorder (DVR)

IP Camera

OptionalWorkstation(s)

Printer(Also direct connection can be use)

TCP/IPConnection(LAN/WAN)

CentaurDoor Controller

Director

dial-up (modem)connections

also supported

Burglar AlarmIntegration

Centaur built-in modules:Pro-report: Print detailed reportFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cardslocator: Monitor card holder location in real-timeWavePlayer: Play a sound on any system event

Page 5: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

sITe CoNFIgUrATIoN QUICK FormCompany name: ___________________________

Address: _________________________________

City: _____________________________________

State: ____________________________________

Zip Code: _________________________________

Contact 1: ________________________________

Tel: ______________________________________

Contact 2: ________________________________

Tel: ______________________________________

Contact 3: ________________________________

Tel: ______________________________________

qDirect serial port qRS-232 NULL modem cable qConverter (25’ and more)

qDial Up (modem) Modem number: ____________________________________

qTCP/IP IP Address: ________________________________________

PC (Centaur server) to controller communication type

doors name reader door Contact

requestto exit

door strike maglock Pull

station

1: q Entry q Exit q q q q q

2: q Entry q Exit q q q q q

3: q Entry q Exit q q q q q

4: q Entry q Exit q q q q q

5: q Entry q Exit q q q q q

6: q Entry q Exit q q q q q

7: q Entry q Exit q q q q q

8: q Entry q Exit q q q q q

Dealer: ________________________________

Tel: ___________________________________

installation diagram2 Reader/Keypads per CT-V900-A or CA-A470-A

Ct-V900-a (1)

Door: ____________

Door: ____________

Ct-a470-a (1)

Door: ____________

Door: ____________

Ct-a470-a (2)

Door: ____________

Door: ____________

Ct-a470-a (3)

Door: ____________

Door: ____________

CT-V900-A2-Door Controller

RS-232 7.6m (25ft) max.

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= LowB-= Low

Controller Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 controller network. (Furthest module can be up to 1220m(4000ft) from start point)

END POINTof the RS-485 controller network

CT-V900-A

CT-V900-A

CT-V900-A2-Door Controller

CT-V900-A

CT-V900-A2-Door Controller

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING

DIRECT CONNECT CONFIGURATION

Example of Jumper Settings

HIGH

HIGH

EOL

EOL

LOW

LOW

Jumper set to LOW

Jumper set to HIGH

Jumper set to EOL ON

Jumper set to EOL OFF

CONTROLLER NETWORK JUMPERS

ADDRESSABLE DIPSWITCH

E-BUSNETWORK JUMPERS

CT-V900-A CUT VIEW

At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF

At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

Addressable dipswitch

Addressable dipswitch

Addressable dipswitch

Page 6: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

ProduCts Quantity 26-bits Wiegand keyPads

galeo/W: 26-bit Wiegand keypad, integrated Piezo/Buzzer, 12Vdc, potted electronics, polished heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper)

Proximity Card and badges qBP: leather key ring badge qCS: Clamshell card qISO: Printable card

qBTAG: Blue polycarbonate key ring badge

qPP: Stylish black polycarbonate tear drop badge

rs-485 to rs-232 ConVerter - Ca-a360-a rs-485 to usb/rs-232 ConVerter - Ca-a360-usb rs-232 tCP/iP ConVerter - Ca-ethr-a modem door strike Strike ANSI fail secure: qAR (12VAC/CC) qAR24 (24VCC) Strike ANSI fail safe: qARI (12VCC) qARI24 (24VCC) Strike ANSI continous fail secure: qARCC (12VCC) Strike EFF-EFF fail secure: qAG (12VAC/CC) qAG24 (24VCC) Strike EFF-EFF fail safe: qAGI (12VCC) qAGI24 (24VCC) Strike EFF-EFF continous fail secure: qAGCC (12VCC)

eleCtromagnets V5S: 1100lbs (500kg) holding force, surface mount, 12/24Vdc

V5EI: 1100lbs (500kg) holding force, sliding door applications, flush mount, 12/24Vdc

VSI5R: 1100lbs (500kg) holding force, exterior applications & High-traffic areas, 12/24Vdc

CZ3000: 3000lbs (1500kg) holding force, self-Aligning, 12/24Vdc

Pull station loCk Control module - Ca-a110-P door ContaCt qFlush mount qSurface mount

reQuest to exit Motion detector

BPEST: Touch-to-Exit button

BEI: Stainless steel touch-sensitive handle

POI: Touch-sensitive electronics built-in in the handle, 14” x 2” (39.5cm x 5cm)

EST: Transforms any metallic surface into a request-to-exit device

rs-485 netWork hub - Ca-a370-P qPieZo: q sirene: biometriC Finger Print reader (dgid/W) other:

CT-V900-A2-Door Controller

PO

SIT

ION

GNDTX

B-

+12V

RXGND

A+GND

RE

CE

IVE

TRA

NS

MIT

PO

WE

R

CA

-A36

0-A

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= LowB-= Low

Controller Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

Controller Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)

END POINTof the RS-485 controller network

CT-V900-A

CT-V900-A

CT-V900-A2-Door Controller

CT-V900-A

CT-V900-A2-Door Controller

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING A

CA-A360-A CONVERTER

RS-2327.6m (25ft) max.

Since the converter is now the closest to the server, it is the START POINT.

The converter’s EOL jumper is ON by default and its HIGH/LOW bias jumpers are LOW by default.

Addressable dipswitch

Addressable dipswitch

Addressable dipswitch

7.6m (25ft) max.

HArDwAre LIsT

Page 7: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

HArDwAre LIsT

Company Name: ________________________

Address: ______________________________

City: __________________________________

State: _________________________________

Zip Code: ______________________________

Name: ________________________________

Title: __________________________________

Tel: ___________________________________

Cell: __________________________________

E-mail: ________________________________

door tyPe

Controlled entry with Free exit Controlled entry and exit

FrontDoor

Employees Door

To next controller

Requestto exit

Requestto exit

To access control server

Entryreader

Doorstrike*

Entryreader

CT-V900Controller

#1

AC

Doorstrike*

* Can be replace by electromagnet

To access control server To next controller

AC

CT-V900-AController

#1

Door contact

Protected Door

Entry reader

Exit readerDoorstrike*

RS-485 Communication bus

* Can be replace by electromagnet

ProduCts Qty

2-door Controller - Ct-V900-a 2-door exPansion module - Ca-a470-a (3 max. per CT-V900-A controller) 12V-7Ah battery (You need 2 per CT-V900-A and 1 per CA-A470-A or CA-A480-A) CdVi150 transformer: 16VAC and 24VAC,150VA (One CDVI150 transformer can supply one CT-V900-A and tree CA-A470-A)

Proximity reader With multiPle ProtoColes built-in

DGLP FN WLC: Multi-Technology Polycarbonate proximity reader

DGLP WLC: Multi-Technology Polycarbonate proximity reader

DGLI F WLC: Multi-Technology Stainless steel proximity reader

DGLI WLC: Multi-Technology Stainless steel proximity reader

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

+S

P+1

2VR

1/K

PD

R1/

KP

CR

1/K

PB

R1/

KPA

OU

T2O

UT1

R1/

D1

R1/

D0

R1/

0VR

1/+5

V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= ON

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= LowB-= Low

START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)

END POINTof the RS-485E-bus network

CT-V900-A2-Door Controller

CT-V900-A

CA-A480-A CA-A480-A

CA-A470-A CA-A470-A

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 E-BUS NETWORK

At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF

At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

Addressabledipswitch

Addressabledipswitch

Addressabledipswitch

Addressabledipswitch

Page 8: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

E-bus Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 E-bus network. (Furthest modules can be up to 1220m (4000ft) from start point)

END POINTof the RS-485 E-bus network

CT-V900-A2-Door Controller

CT-V900-A

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

CA-A480-A

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

E-bus Network Jumper settingsEOL= ON

Bias High/LowA+= HighB-= High

CA-A480-A

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

CA-A470-A

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

E-bus Network Jumper settingsEOL= ON

Bias High/LowA+= LowB-= Low

CA-A470-A

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE WITH THE CT-V900-A NO LONGER THE START POINT

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

This example depicts an existing RS-485 E-bus network with 1 CA-A470-A and 2 CA-A480-A to which we are adding a CA-A470-A after the initial installation.

In our example the END POINT, the CA-A480-A, is at 914m (3000ft) from the CT-V900-A and the new CA-A470-A module you would like to add is 30m (100ft) from the CT-V900-A.

The flexibility of the RS-485 E-bus network jumpers permits you to locate the new CA-A470-A close to the CT-V900-A by simply re-configuring jumper settings of the new START POINT and what was the start point before.

This permits you to have a 30m (100ft) cable run instead of914m (3000ft).

Addressable dipswitch

Addressable dipswitch Addressable dipswitch Addressable dipswitch

Centaur System Architecture

LCD DisplayCK-TRAK-L

(Max. 8 per CT-V900-A)

Elevator ControllerCA-A480-A

(Max. 8 per CT-V900-A)

Relay Expansion ModuleCA-A460-P

(Max. 2 per CT-V900-A)

2-Door Expansion ModuleCA-A470-A

(Max. 3 per CT-V900-A)

to other Ct-V900-a controllers

E-bus NEtwork ModulE CapaCity

to PC Centaur serverSee diagram above Furthest modules

can be up to 1220m (4000ft) away from the

CT-V900-A

Digital Video Recorder (DVR)

IP Camera

OptionalWorkstation(s)

Printer(Also direct connection can be use)

TCP/IPConnection(LAN/WAN)

CentaurDoor Controller

Director

dial-up (modem)connections

also supported

Burglar AlarmIntegration

Centaur built-in modules:Pro-report: Print detailed reportFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cardslocator: Monitor card holder location in real-timeWavePlayer: Play a sound on any system event

Page 9: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

sITe CoNFIgUrATIoN QUICK FormCompany name: ___________________________

Address: _________________________________

City: _____________________________________

State: ____________________________________

Zip Code: _________________________________

Contact 1: ________________________________

Tel: ______________________________________

Contact 2: ________________________________

Tel: ______________________________________

Contact 3: ________________________________

Tel: ______________________________________

qDirect serial port qRS-232 NULL modem cable qConverter (25’ and more)

qDial Up (modem) Modem number: ____________________________________

qTCP/IP IP Address: ________________________________________

PC (Centaur server) to controller communication type

doors name reader door Contact

requestto exit

door strike maglock Pull

station

1: q Entry q Exit q q q q q

2: q Entry q Exit q q q q q

3: q Entry q Exit q q q q q

4: q Entry q Exit q q q q q

5: q Entry q Exit q q q q q

6: q Entry q Exit q q q q q

7: q Entry q Exit q q q q q

8: q Entry q Exit q q q q q

Dealer: ________________________________

Tel: ___________________________________

installation diagram2 Reader/Keypads per CT-V900-A or CA-A470-A

Ct-V900-a (1)

Door: ____________

Door: ____________

Ct-a470-a (1)

Door: ____________

Door: ____________

Ct-a470-a (2)

Door: ____________

Door: ____________

Ct-a470-a (3)

Door: ____________

Door: ____________

CT-V900-A2-Door Controller

RS-232 7.6m (25ft) max.

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= LowB-= Low

Controller Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 controller network. (Furthest module can be up to 1220m(4000ft) from start point)

END POINTof the RS-485 controller network

CT-V900-A

CT-V900-A

CT-V900-A2-Door Controller

CT-V900-A

CT-V900-A2-Door Controller

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING

DIRECT CONNECT CONFIGURATION

Example of Jumper Settings

HIGH

HIGH

EOL

EOL

LOW

LOW

Jumper set to LOW

Jumper set to HIGH

Jumper set to EOL ON

Jumper set to EOL OFF

CONTROLLER NETWORK JUMPERS

ADDRESSABLE DIPSWITCH

E-BUSNETWORK JUMPERS

CT-V900-A CUT VIEW

At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF

At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

Addressable dipswitch

Addressable dipswitch

Addressable dipswitch

Page 10: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

Access level 1: __________________________

Schedule 1*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

Access level 2: __________________________

Schedule 2*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

Access level 3: __________________________

Schedule 3*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

Access level 4: __________________________

Schedule 4*: ___________________________

Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq

Door: 1 2 3 4 5 6 7 8 qqqqqqqq

aCCess leVels and sChedules deFinition

Card user name Card numberFamily : Number aCCess leVel

1: : 2: : 3: : 4: : 5: : 6: : 7: : 8: : 9: : 10: : 11: : 12: : 13: : 14: : 15: : 16: : 17: : 18: : 19: : 20: :

* HH:MM to HH:MM

Key FeATUres IN VersIoN 5.1• Guard Tour features: Allows check point validation using card readers, input points (Motion sensors, key

switches, or push buttons) or data collectors.• Asset Management, find quickly who is in possession of your assets and for how long.• Biometrics integration (CDVI’s DGID/W/US, L-1 model 4G, Sagem and more)• Alarm integration: Arm/disarm an alarm system with a double card swipe• Card Usage/Card Counter options (use a card up to 255 times on a door) • All reports including Time & Attendance reports can be sent automatically by e-mail• Unassign card on period of inactivity (up to 365 days)• New DVR support (see the list on the front page)• Import/export users, cards and all related objects• Manually control doors from event window• New controller standalone functionality a. Activate relay on access granted, extended access (Disabled person) b. Activate relay on door forced open status c. Activate relay on door open too long status d. Relay follow input (keep light open on movement) e. Maintain door locked/unlocked on valid card (classroom application)• Play waves on alarm from the administration console• Additional filters in Locator• Now support DNS in the controller properties• Added French support in WavePlayer• Parking group: Reset parking count• SAP import for users/cards• When User/Visitor status is changed, it is now reflected on the cards• Support TELACCESS• Support DGLM magnetic stripe reader• Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management dialog (Add, Delete, Modify and etc.). e. New usage billing report f. New access report type (access granted only) g. New option in Tracker Preferences (show valid users only)

INTEGRATED ACCESS CONTROL

sITe CoNFIgUrATIoN QUICK Form

imPortant --- imPortant Please note that Centaur 5.1 version is compatible with Centaur 5.0 Dongles.

Firmware update of CT-V900-A will be necessary to perform new 5.1 features. See details below:R2-C3-98 - Works with Centaur 5.1 and support up to 8,190 cards

R2-G3-98 - Works with Centaur 5.1 + LCD Tracker feature and support up to 4,914 cards

Page 11: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

HArDwAre LIsT

Company Name: ________________________

Address: ______________________________

City: __________________________________

State: _________________________________

Zip Code: ______________________________

Name: ________________________________

Title: __________________________________

Tel: ___________________________________

Cell: __________________________________

E-mail: ________________________________

door tyPe

Controlled entry with Free exit Controlled entry and exit

FrontDoor

Employees Door

To next controller

Requestto exit

Requestto exit

To access control server

Entryreader

Doorstrike*

Entryreader

CT-V900Controller

#1

AC

Doorstrike*

* Can be replace by electromagnet

To access control server To next controller

AC

CT-V900-AController

#1

Door contact

Protected Door

Entry reader

Exit readerDoorstrike*

RS-485 Communication bus

* Can be replace by electromagnet

ProduCts Qty

2-door Controller - Ct-V900-a 2-door exPansion module - Ca-a470-a (3 max. per CT-V900-A controller) 12V-7Ah battery (You need 2 per CT-V900-A and 1 per CA-A470-A or CA-A480-A) CdVi150 transformer: 16VAC and 24VAC,150VA (One CDVI150 transformer can supply one CT-V900-A and tree CA-A470-A)

Proximity reader With multiPle ProtoColes built-in

DGLP FN WLC: Multi-Technology Polycarbonate proximity reader

DGLP WLC: Multi-Technology Polycarbonate proximity reader

DGLI F WLC: Multi-Technology Stainless steel proximity reader

DGLI WLC: Multi-Technology Stainless steel proximity reader

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= OFF

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= ON

Bias High/LowA+= HighB-= High

E-bus Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= LowB-= Low

START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)

END POINTof the RS-485E-bus network

CT-V900-A2-Door Controller

CT-V900-A

CA-A480-A CA-A480-A

CA-A470-A CA-A470-A

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 E-BUS NETWORK

At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF

At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

Addressabledipswitch

Addressabledipswitch

Addressabledipswitch

Addressabledipswitch

Page 12: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

ProduCts Quantity 26-bits Wiegand keyPads

galeo/W: 26-bit Wiegand keypad, integrated Piezo/Buzzer, 12Vdc, potted electronics, polished heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper)

Proximity Card and badges qBP: leather key ring badge qCS: Clamshell card qISO: Printable card

qBTAG: Blue polycarbonate key ring badge

qPP: Stylish black polycarbonate tear drop badge

rs-485 to rs-232 ConVerter - Ca-a360-a rs-485 to usb/rs-232 ConVerter - Ca-a360-usb rs-232 tCP/iP ConVerter - Ca-ethr-a modem door strike Strike ANSI fail secure: qAR (12VAC/CC) qAR24 (24VCC) Strike ANSI fail safe: qARI (12VCC) qARI24 (24VCC) Strike ANSI continous fail secure: qARCC (12VCC) Strike EFF-EFF fail secure: qAG (12VAC/CC) qAG24 (24VCC) Strike EFF-EFF fail safe: qAGI (12VCC) qAGI24 (24VCC) Strike EFF-EFF continous fail secure: qAGCC (12VCC)

eleCtromagnets V5S: 1100lbs (500kg) holding force, surface mount, 12/24Vdc

V5EI: 1100lbs (500kg) holding force, sliding door applications, flush mount, 12/24Vdc

VSI5R: 1100lbs (500kg) holding force, exterior applications & High-traffic areas, 12/24Vdc

CZ3000: 3000lbs (1500kg) holding force, self-Aligning, 12/24Vdc

Pull station loCk Control module - Ca-a110-P door ContaCt qFlush mount qSurface mount

reQuest to exit Motion detector

BPEST: Touch-to-Exit button

BEI: Stainless steel touch-sensitive handle

POI: Touch-sensitive electronics built-in in the handle, 14” x 2” (39.5cm x 5cm)

EST: Transforms any metallic surface into a request-to-exit device

rs-485 netWork hub - Ca-a370-P qPieZo: q sirene: biometriC Finger Print reader (dgid/W) other:

CT-V900-A2-Door Controller

PO

SIT

ION

GNDTX

B-

+12V

RXGND

A+GND

RE

CE

IVE

TRA

NS

MIT

PO

WE

R

CA

-A36

0-A

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= LowB-= Low

Controller Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

Controller Network Jumper settingsEOL= OFF

Bias High/Low JumpersA+= HighB-= High

Controller Network Jumper settingsEOL= ON

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)

END POINTof the RS-485 controller network

CT-V900-A

CT-V900-A

CT-V900-A2-Door Controller

CT-V900-A

CT-V900-A2-Door Controller

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING A

CA-A360-A CONVERTER

RS-2327.6m (25ft) max.

Since the converter is now the closest to the server, it is the START POINT.

The converter’s EOL jumper is ON by default and its HIGH/LOW bias jumpers are LOW by default.

Addressable dipswitch

Addressable dipswitch

Addressable dipswitch

7.6m (25ft) max.

HArDwAre LIsT

Page 13: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

Project: _______________________________ Door Name:_______________________

Door contact � Surface � Flush

� Electromagnet� 24V � 12V

� Door Strike � 24V � 12V� Fail Safe � Fail Secure

REQUEST-TO-EXIT (REX)� Motion Detector� Pull Station� Push Button� Push Bar/Crash Bar

READING DEVICE (ENTRY)� Reader Technology:_______________� Keypad Technology:_______________

READING DEVICE (EXIT)� Reader Technology:_______________� Keypad Technology:_______________

� Fixed Door

Electromagnet �24V � 12V �

Door contact � Surface � Flush

Fixed Door �

DOUBLE-DOOR OPTION

door typeq Access (Most common setting)q Elevatorq Entry Anti-passback (1 CT-V900-A only, 8 readers)q Exit Anti-passback (1 CT-V900-A only, 8 readers)q Global Entry Anti-passback (multiple doors)q Global Exit Anti-passback (multiple doors)q Parking Global Entry Anti-passbackq Parking Global Exit Anti-passbackq Two Card Rule

optionsq Unlock on late open (Ignore the unlock schedule until the first person arrives) q Time and attendanceq Sign-Out reader (Visitor)

unlock schedule (optional)Schedule time (HH:MM): __________________

Days: S M T W T F S qqqqqqq

interlock (man-trap)With door (input): _________________________

door Programming

CT-V900-A Door HArDwAre

liteCs-aC-lite

standardCs-aC-std

ProfessionalCs-aC-Pro*

enterpriseCs-aC-ent*

Free**

starter PaCk

sites 1 64 64 64 1

serial Ports 1 1 1 4 4

dial up connection Yes Yes Yes Yes Yes

tCP/iP connection Yes Yes Yes Yes Yes

Cards 512 2,048 per site(131,072 max.)

8,196 per site(524,544 max.)

16,384 per site(1,048,576 max.) 512

Controllers 16 32 per site(2,048 max.)

64 per site(4,096 max.)

256 per site(16,384 max.) 1

doors 16 128 per site(8,192 max.)

512 per site(32,768 max.)

2048 per site(131,072 max.) 8

elevator Control - Yes Yes Yes Yes

elevator Cabs - 64 per site(4,096 max.)

128 per site(8,192 max.)

512 per site(32,768 max.) 2

Floors per cab - 64 64 64 64

Floor groups - 128 per site(8,192 max.)

128 per site(8,192 max.)

128 per site(8,192 max.) 128

dVr module - Yes Yes Yes Yes

Visitor management - Yes Yes Yes Yes

Parking management - Yes Yes Yes Yes

guard tour - Yes Yes Yes Yes

asset management - Yes Yes Yes Yes

* Comes with a workstation license New ** Free from our web site, www.cdvi.ca Security dongle not required

INTEGRATED ACCESS CONTROL Version 5.1

Workstation license (Cs-WsliC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules.

enhanced security dongle. Previous dongle not supported by Centaur V5.0 and 5.1

every Centaur edition includes a Centaur server with an administration console plusall these software modules:Pro-report with tracker: On demand, scheduled or customized reportsFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cards, include Photo-IDlocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event

Page 14: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

Programmable outPuts

reader 1 reader 2out 1(Default: Green LED)

out 3(Default: Green LED)

out 2(Default: Red LED)

out 4(Default: Red LED)

out 5(Default: Buzzer)

out 6(Default: Buzzer)

Zone inPuts

Without atZ (Zone doubling) With atZ (Zone doubling)Z1Default:Contact door 1

Z2

Z3Default:REX door 1

Z4

Z5 Z6

Z7 Z8

Z9Default:Contact door 2

Z10

Z11Default:REX door 2

Z12

Z13 Z14

Z15 Z16

relaysRelay 1(Onboard)

Relay 2(Onboard)

adding one relay expansion adding a second relay expansion

Relay 3 Relay 10

Relay 4 Relay 11

Relay 5 Relay 12

Relay 6 Relay 13

Relay 7 Relay 14

Relay 8 Relay 15

Relay 9 Relay 16

c d v i . c a

CT-V900-A Door HArDwAre

manufacturing access Control since 1985

Improvements and built-in features:Centaur improvements:• Automaticallye-mailscheduledreports

• CardUsage/CardCounteroptions (useacardupto255timesonadoor)

• Alarmintegration:arming/disarmingan alarmpanelondualbadge(keyswitchinput)

Visitor ManagementCentaurVisitorManagementwillallowyoutose-curelycontrolthecomingsandgoingsofallvisitors.

Parking ManagementTheCentaurParkingManagementallowsyoutoquicklyseehowmanyparkingplacesareused,bywhichuserandhowmanyparkingspacesareavailableinrealtime.

LocatorMonitorthelocation(inside/outside)ofeachcardholderinreal-time.View/Printreportswithaclickofabutton.Obtaindetailedcardholderinformationwithadouble-clickofthemousebutton.Excellentformuster-pointapplications.

Print or e-mail reports of your activitiesTracktheaccessesofaspecificemployee,verifywhoaccessedaspecificdoorataprecisedateandtimeorcalculatehowmanyhoursofovertimeyouwillpay.Centaurreportwizardallowsyoutocreateyourownreportseasily.

Live Interactive Floor Plans • Createorimportupto512floorplans• Fulllibraryoficons(orcreateyourown)• Event-basedtrigger-actions

Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format.

In Constant Evolution

to fulfill your needs

in access control

New Version 5.1

New features in CeNTAUr Version 5.1:Guard Tour FeatureLive interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports.

Asset Management FeatureWhybuysomethingthatyoualreadyhave?Keeptrackofyourassetsandsavetimeandmoney.Findquicklywhoisinpossessionofyourassets.Areportcanbegeneratedandsentautomaticallyviaemail.

Biometric IntegrationCentaurisapowerfulsolutionforareasrequiringenhancedsecuritybyauthenticatingfingerprints.Capturing,managingandtransferringbiometricdataisnoweffortlesswithworld-renownedfingerprintreaderssuchasCDVI’sDGID/W/US,L-1(model4G),Sagemandmore.

CeNTAUr 5.1 now supports the followingDVr manufacturers:

• Capture• Dahua• Dedicated Micros• Digiop• Digital WatchDog• Eneo• Everfocus• HIK Vision• Infinova• Microcom• Milestone• NUUO• Samsung• Sphere• ViewGate• Vivotek IP Camera• Vivotek

Page 15: CT-V900-A Door HArDwAre New Version 5 · • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management

c d v i . c a c d v i . c a

INTEGRATED ACCESS CONTROL

e-bus exPansion module CaPaCity 2-Door Expansion Module (CA-A470-A) 3 Relay Expansion Module (CA-A460-P) 2 Elevator Controller (CA-A480-A) 8 LCD Keypad (CK-TRAK-L) 8

eQuiPment Wire tyPe siZe max. lengthCard reader (1 LED or 1 LED & Buzzer)

and Wiegand keypad 6 conductors, stranded, shielded (foil),

drain conductor, Belden: 5304FE 18AWG 150m (500ft.)

Card reader (2 LEDs & Buzzer) 8 conductors, stranded, shielded (foil),drain conductor, Belden: 5306FE 18AWG 150m (500ft.)

Zone input 4 conductors, copper (JKT) 22AWG 600m (2000ft.)

Door strike & AC transformer for controller 2 conductors, solid copper 18AWG 150m (500ft.), AC transformer: 8m (25ft.)

RS-485 bus Ethernet CAT 5e, 4 pairs 24AWG 1220m (4000ft.)

Z1: 1K Ohm Z2: 2.2K Ohm

EOL1K Ohm

Optional Loop Supervision

MagneticDoor Contact

Request-to-Exit Button (EXIT-BLP)

+-

+-

+

-

+

-

+-

+-

+

-

!Always consult the regulatory agency in your area for existing regulations regarding doors designated as emergency exits.

!Reader wiring may differ from diagram. Please consult your documentation for details.

Lock Control Module (optional)

CA-A110-P

GND

GND

A1+

B1- GND

GND

A2+

B2-

CoNtrollEr iNputs (up to 16 pEr CoNtrollEr)

+-Power

Supply

+-Power

Supply

Connect directly to controller lock terminals

ElECtroMagNEtiC loCk or door strikE optioN

alarM souNdEr

2-door CoNtrollEr

Ct-V900-a

R1/DO

GND

R1/D112VOUT1OUT2OUT5

GREEN

BLACK

WHITEREDYELLOW (green LED)ORANGE (red LED)BROWN (buzzer)

Blue (Clock) Not applicable with Centaur System

R2/DO

GND

R2/D112VOUT3OUT4OUT6

DO

-

D1+V (green LED)R (red LED)B (buzzer)

H (Clock) Not applicable with Centaur System

Connect earth terminal toa certified earth ground

Transformater CDVI15024 Vac, 75VAAlso includes an output of16 VAC (75 VA) that can power up to 32-door expansion modules CA-A470-A

2 batteries(12V, 7AH)

connected in series for 24V backup

Tamper Switch N.C. Contact

To next controller of a site.

module netWork(e-bus rs-485)Furthest module can be installed up to 1220M (4000ft) away from the CT-V900-A controller

PolycarbonateProximityreaderdglP Fn WlC26

stainless steelProximity reader

dgli WlC26

CoNtrollEr NEtwork(rs-485)

Fire alarm contact for Lock1 & Lock2

PolycarbonateProximityreaderdgl

ISO - Thin card for printing

CS - Standard clamshell card

ISO - ISO - ISO - ISO -

CS - CS - Standard clamshell cardStandard clamshell cardCS - CS - Standard clamshell cardStandard clamshell card