16
Introduction CTi-mem Components User Guide CTi-mem Selection 152 155 159 163 Contents

Cti mem catalog (20120831)

  • Upload
    kei-lim

  • View
    226

  • Download
    3

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Cti mem catalog (20120831)

Introduction

CTi-mem Components

User Guide

CTi-mem Selection

152

155

159

163

Contents

Page 2: Cti mem catalog (20120831)

Customized Titanium Membrane

152

Custom

ized Titanium

Mem

brane

Introduction

has developed independently by Neobiotech Co., Ltd., Which is the customized

titanium membrane with minimum cutting and bending of it for attaching on the location of part used. This

product, customized titanium membrane, solved the existed rectangle membrane's own inconvenience of

cutting problem.

Page 3: Cti mem catalog (20120831)

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

153

Introduction

1. Biocompatibility

Cp. Ti material has an excellent biological stability, and it is beneficial to bone formation.

2. Strong

Compare to absorbable membrane, it has a superior strength and excellent retention of BMP space.

3. Flexibility

Has an excellent flexibility due to the thinness, and it can easily produce a desired shape.

4. Customized shape

Depending on the location, it provides variety sizes of membrane that are suitable for treatment use.

Membrane with a minimum of trimming can be made into the shape you want.

5. Implant fixation

Even without the use of membrane fixing screw, it can be fixed directly to Implant.

6. Vertical Augmentation

Vertical Augmentation is adjustable with using 1mm, 1.5mm, 2mm of CTi Spacer.

7. 1-stage Surgery

After completing GBR, the CTi-Mem can be easily removed without having 2-stage surgery.

Advantage of CTi-Mem

Page 4: Cti mem catalog (20120831)

Customized Titanium Membrane

154

Custom

ized Titanium

Mem

brane

Introduction

CTi-mem Characteristic

1

2

3

4

5

C

6

Lingual fingerMain function is to maintain the efficient space by covering the 2~3mm of lingual defect with easy bending. Simple

cutting if necessary.

Proximal fingerNecessary when vertical augmentation of Misial&distal defect, shape formation available with easy bending. Cut

the unnecessary part After measure the width of proximal.

Lateral augmentation part- Put the C part as the centre and bending of a curved for 2~3mm thick side bone formation.

- Bending the side extrusion inwards in order to protect bone transplant and form the space. Porous exists to

minimize the soft tissue exposure.

Lateral cover- Cover part of side transplant bone materials. Choose the size depends on defect length.

- Three dimensional bending available, no porous exists to be able to remove the CTi-mem with simple 2nd surgery.

FootProtect the transplant material as bending inwards, have membrane fixation by contacting the existing bone.

Fixing holeThe hole formed to fix the CTi-mem to fixture. Firstly connect the CTi Spacer to fixture, lift up the CTi-mem and

then fix with the CTi Healing Abutment or CTi Cover Cap. Vertical bone formation can be decided depends on CTi

Spacer height.

1

2

3

4

5

6

Page 5: Cti mem catalog (20120831)

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

155

CTi-mem has three A types, nine B and C types and three E types. Total of30 kinds of membranes are customized.

A-Type 1 Wall

Augmentation (Buccal or Lingual)

B-Type 2 Wall

Augmentation (Buccal - Proximal)

C-Type 3 Wall

Augmentation (Buccal-Lingual-Proximal)

P(mm) W(mm) L(mm)(Proximal Width) (Buccal Width) (Buccal Length) Code Product Name

4 8 6 A1 ATMBN 0810S

4 10 8 A2 ATMBN 0912S

4 10 10 A3 ATMBN 0915S

P(mm) W(mm) L(mm)((Proximal Width) (Buccal Width) (Buccal Length) Code Product Name

6 B1 ATMBN 0910L

7 9 8 B2 ATMBN 0912L

10 B3 ATMBN 0915L

6 B4 PTMBN 1210S

10 12 8 B5 PTMBN 1212S

10 B6 PTMBN 1215S

6 B7 PTMBN 1210L

12 12 8 B8 PTMBN 1212L

10 B9 PTMBN 1215L

P(mm) W(mm) L(mm)(Proximal Width) (Buccal Width) (Buccal Length) Code Product Name

6 C1 ATMLN 0910L

7 9 8 C2 ATMLN 0912L

10 C3 ATMLN 0915L

6 C4 PTMLN 1210S

10 12 8 C5 PTMLN 1212S

10 C6 PTMLN 1215S

6 C7 PTMLN 1210L

12 12 8 C8 PTMLN 1212L

10 C9 PTMLN 1215L

W

L

P

W

L

P

W

L

P

1. CTi-mem

CTi-mem Component

Page 6: Cti mem catalog (20120831)

Customized Titanium Membrane

156

Custom

ized Titanium

Mem

brane

CTi-mem Component

D-Type ITI Type (Non-fixed)

1 Wall Augmentation

D-Type ITI Type (Non-fixed)

2 Wall Augmentation

E-TypeUniversal Type (Submerged & Non-fixed)

P(mm) W(mm) L(mm)(Proximal Width) (Buccal Width) (Buccal Length) Code Product Name

6 D1 ATUBN 0910L

7 9 8 D2 ATUBN 0912L

10 D3 ATUBN 0915L

P(mm) W(mm) L(mm)((Proximal Width) (Buccal Width) (Buccal Length) Code Product Name

6 D4 PTUBN 1210S

10 12 8 D5 PTUBN 1212S

10 D6 PTUBN 1215S

P L(Proximal Width) (Buccal Length)

Code Product Name

12 15 E1 CTM 1215

12 20 E2 CTM 1220

15 20 E3 CTM 1520

W

L

P

W

L

P

L

P

Page 7: Cti mem catalog (20120831)

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

157

CTi-mem Component

- By connecting CTi spacer to the implant platform of the head, GBR can becontroled.

- After mounting the Cti-mem (A, B, C type) in upper part of being enteredand placed implant. Fix the CTi-mem with CTi Cover cap or CTi healingabutment.

- Available to control the vertical augmentation amount by using optionalthree types of CTi Spacer that are 1mm, 1.5mm, 2mm.

Diameter(�) Height(mm) Product Name

0.5 ISCTS 4005

1 ISCTS 40104.0

1.5 ISCTS 4015

2 ISCTS 4020

Type Diameter(�) Height(mm) Product Name

1 ENCTS 3710

Narrow 3.5 1.5 ENCTS 3715

2 ENCTS 3720

1 ERCTS 4010

Regular 4.0 1.5 ERCTS 4015

2 ERCTS 4020

1 EICTS 5010

Wide(3i) 5.0 1.5 EICTS 5015

2 EICTS 5020

1 EBCTS 5010Wide

5.0 1.5 EBCTS 5015(Branemark)

2 EBCTS 5020

EB CTi Spacer

IS CTi Spacer

2. CTi Spacer

Diameter

Height

Diameter

Height

Used for fixing the CTi-mem that has been mounting with CTi Spacer, andSubmerged purpose.

Diameter(�) Heightter(mm) Product Name

4.0 1.5 CTC 40

3. CTi Cover Cap

Diameter

Height

Page 8: Cti mem catalog (20120831)

Customized Titanium Membrane

158

Custom

ized Titanium

Mem

brane

CTi-mem Component

Used for fixing the CTi-mem that has been mounting with CTi Spacer, andNon-Submerged purpose.

4. CTi Healing Abutment

Diameter 1(�) Diameter 2(�) Height(mm) Product Name

3.0 CHAG 4040304.0

4.0 CHAG 4040404.0

3.0 CHAG 4050305.0

4.0 CHAG 405040

Product Name

MCCD

Used for picking-up the CTi Cover cap, enter in or lossen the CTi cover capfrom the CTi Spacer.

5. CTi Cover Cap Driver

Product Name

MCCP

CTi-mem contouring Plier is for bending CTi-mem in right form.

6. CTi-mem Contouring Plier

Product Name

MG 00

CTi-guage is for measuring oral proximal width, buccal width and buccallength.

7. CTi Guage

Diameter 1

Diameter 2

Height

� CTi Spacer / CTi Healing Abutment can be close or released by 1.2 Hex Driver.

Page 9: Cti mem catalog (20120831)

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

159

User Guide

1. Finish the implantation of the Fixture.

2. Choose CTi-Mem by using the measurement from CTi gauge and length space of bone graft.

3. Combine the membrane healing post with the fixture. By selecting the post, you need to know the

system of the implant, volume of the bone graft and EB and IS implant have two types of height(1mm,

1.5mm, 2mm) which this information can give good selection.

4. Proceed Bone graft.

5. Make model of the selected CTI- Mem. Do not bend rapidly in the same area or it will fracture the

CTI- Mem.

6. Stable the CTI-Mem and combine the membrane healing cap or membrane cover cap with below 10 Ncm. - With the gum height use suitable healing cap.

- Use cover cap for 2nd stage surgery.

7. Suture the Soft tissue.

1. A type : 1 wall augmentation

Placement for buccal in bone defect area

Implant at the area of bonedefect

Combine CTi Spacer withimplant

Image of CTi Spacer withimplant

Bone graft at Bone defect area

Bend Cti-mem with Con-touring plier

Bend Suitable Form byBending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem

Page 10: Cti mem catalog (20120831)

Customized Titanium Membrane

160

Custom

ized Titanium

Mem

brane

User Guide

2. B type : 2 wall augmentation

Placement for buccal, proximal in bone defect area

3. C type : 3 wall augmentaion

Placement for buccal, proximal and lingual in bone defect area

Implant at the area of bonedefect

Combine CTi Spacer withimplant

Image of CTi Spacer withimplant

Bone graft at Bone defect area

Bend Cti-mem with Con-touring plier

Bend Suitable Form byBending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem

Implant at the area of bonedefect

Combine CTi Spacer withimplant

Image of CTi Spacer withimplant

Bone graft at Bone defect area

Bend Cti-mem with Con-touring plier

Bend Suitable Form byBending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem

Page 11: Cti mem catalog (20120831)

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

161

User Guide

4. D type : 1 wall agumentation for ITI type

Placement for buccal in bone defect area

5. D type : 2 wall agumentation for ITI type

Placement for buccal and proximal in bone defect area

Detect the area of bone defect Combine cover screw orhealing abutment

Bone graft at Bone defect area Bend Cti-mem with Contouringplier

Bend Suitable Form by BendingCTi-mem

Before suture, place CTi -memat bone defect area

Detect the area of bone defect Combine cover screw orhealing abutment

Bone graft at Bone defectarea

Bend Cti-mem with Contouringplier

Bend Suitable Form by BendingCTi-mem

Before suture, place CTi -memat bone defect area

Page 12: Cti mem catalog (20120831)

Customized Titanium Membrane

162

Custom

ized Titanium

Mem

brane

User Guide

6. E type : Non-fixed Submerged

Placement for large bone defect area

1. Practitioners should use after fully understand the handling and precautions of the product.

2. Since the product is supplied as sterile, CTi-mem should be used immediately after it is opened from

the package.

3. In the case of package is damaged, the condition of sterilization is likely to be damaged. Therefore, it

needs to be discarded.

4. Inadvertent exposure by a carelessness of suture can cause a redness, swelling and tissue to be

eliminated. Therefore, it needs to be removed.

5. Improper selection of patients or procedures can lead to a failure of treatment.

6. CTi-mem is a disposable single- use product. Do not reuse.

�Warning

Detect the area of bone defect Combine cover screw orhealing abutment

Bone graft at Bone defect area Bend Cti-mem with Contouringplier

Bend Suitable Form by BendingCTi-mem

Before suture, place CTi -memat bone defect area

Page 13: Cti mem catalog (20120831)

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

163

CTi-mem Selection

1. Depends on the wall situation, choose A, B, C type from the CTi-men.

2. Proximal width (p) of Occlusal part that needs to be covered by Membrane is measured in oral with

determination of the 'p' size. If Proximal defect is not existed, amputate the proximal when it's 1wall

choose A, and when it's b-l defect choose C for the amputation.

3. W (Buccal Width) can be decided by P (Proximal Width) and P can be measured From B and C.

Page 14: Cti mem catalog (20120831)
Page 15: Cti mem catalog (20120831)

Introduction

Type of Ti-mesh

166

166

Contents

Page 16: Cti mem catalog (20120831)

Neo Titanium Mesh

166

Neo Titanium

Mesh

Introduction

Type of Ti-mesh

Neo titanium mesh can be trimmed by customer’s need (Thickness 0.085mm hole

size �0.8)

20mm 25mm

35mm 50mm

20mm

12mm

35mm

25mm

Size Code Product Name

20 x 12 T1 TMN 122008

25 x 20 T2 TMN 202508

35 x 25 T3 TMN 253508

50 x 35 T4 TMN 355008