Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Basic Equipment:
capacitive Multi-Touch-Display in the front
defined keys for elementary functions
of the installation such as start/stop,
fixed-value/automatic operation,
interruption, light, etc.
USB -Connection to save measuring data
on USB Stick
Ethernet – Interface/RS 232 – Interface
2 Digital Out, to switch test specimen
ON/OFF
adjustable software-temperature-limiter
min./max.
shelf, stainless steel
entry port Ø 50 mm on the right side
Your benefits:
low consumption data
minimum noise level
user-friendly operation and programming
uniform operation due to identical
Multi-Touch-Display for all chamber sizes
Service-friendly construction
international standards are fulfilled
(CE-Conformity)
The latest generation with innovative technique and future-oriented design.
CTS-Temperature Test Chambers (Bench Top Version)
Test space capacity in Litres: 25 / 50
Temperature range: -40° C / +180° C
-65° C / +180° C
CTS-Temperature Test Chambers (Bench Top Version)
Type
Test space litres
Test space dimensions height mm, appr.
width mm, appr.
depth mm, appr.
Overalll dimensions height mm, appr.
width mm, appr.
depth mm, appr.
Design
Temperature tests
Temperature range °C
Temp. change rate cooling acc IEC 60068-3-5 K/min
Temp. change rate heating acc IEC 60068-3-5 K/min
max. thermal load at +20°C W
Temperature fluctuation K
Nominal voltage
Nominal power kW, appr.
Refrigeration units
Weight kg, appr.
Noise level dB(A)
T-40/25
25
300
350
240
860
510
580
bench top cabinet
-40/+180
6,5
8
400
<± 0,3
230 V +6 /-10%
1/N, 50 Hz
2,2
air cooled
90
50
T-40/50
50
400
400
320
1030
560
660
bench top cabinet
-40/+180
5
5
400
<± 0,3
230 V +6 /-10%
1/N, 50 Hz
2,2
air cooled
130
50
T-65/50
50
400
400
320
1030
560
840
bench top cabinet
-65/+180
4
6
400
<± 0,3
230 V +6 /-10%
1/N, 50 Hz
2,8
air cooled
160
<52
All figures are average values which have been obtained at a temperature of +25°C, without test specimen, without thermal load and without options.
Control: Multi-Touch-Display with integrated programm controller
Test space: Stainless steel grade 1.4301
Refrigerants: environmental friendly refrigerants
Options:
add. entry ports Ø 50 mm,
80 mm und 125 mm
Rack incl. 1 shelf
Table with height 330 or 515 mm
Window, multiple glazed
add. Pt 100 for temperature measuring
on test specimen reversible to
controller function
air dryer system
Temperature protection for test-specimen
CID software for programming and
documentation
variable air speed in the testspace
RS 232 interface changeable to USB
notch
CTS GmbH | Lotzenäcker 21 | D-72379 Hechingen | GermanyTel.: +49 (0) 74 71/98 50-0 | Fax: +49 (0) 74 71/98 [email protected] | www.cts-umweltsimulation.de
Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.
Basic Equipment:
capacitive Multi-Touch-Display in the front
defined keys for elementary functions of
the installation such as start/stop,
fixed-value/automatic operation,
interruption, light, etc.
USB-Connection to save measuring data
on USB Stick
Ethernet – Interface/RS 232 – Interface
2 Digital Out, to switch test specimen
ON/OFF
adjustable software-temperature-limiter
min./max.
shelf, stainless steel
entry port Ø 50 mm on the right side
single-hand operated door handle, lockable
Your benefits:
low consumption data
minimum noise level
user-friendly operation and programming
uniform operation due to identical
Multi-Touch-Display for all chamber sizes
temperature measuring with Pt 100 in air
inlet and air outlet
Service-friendly construction
international standards are fulfilled
(CE-Conformity)
The latest generation with innovative technique and future-oriented design.
CTS-Temperature Test Chambers
Test space capacity in Litres: 100 / 200 / 350 / 600 / 1000 / 1500 / 2000
Temperature range: -40° C / +180° C
-70° C / +180° C
CTS-Temperature Test Chambers / series T-40 and T-70
Control: Multi-Touch-Display with integrated programm controller
Test space: Stainless steel grade 1.4301
Refrigerants: environmental friendly refrigerants
CTS GmbH | Lotzenäcker 21 | D-72379 Hechingen | GermanyTel.: +49 (0) 74 71/98 50-0 | Fax: +49 (0) 74 71/98 [email protected] | www.cts-umweltsimulation.de
Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.
All figures are average values which have been obtained at a temperature of +25°C , without test specimen, without thermal load and without options.
Type
Test space litres
Test space dimensions height mm, appr.
width mm, appr.
depth mm, appr.
Overall dimensions height mm, appr.
width mm, appr.
depth mm, appr.
Temperature tests
Temperature range T-40 /... °C
T-70 /... °C
Temp. change rate cooling T-40 /... K / min
acc. IEC 60068-3-5 T-70 /... K/ min
Temp. change rate heating T-40 /... K / min
acc. IEC 60068-3-5 T-70 /... K/ min
max. thermal load at +20°C T-40 /... W
T-70 /... W
Temperature fluctuation K
Nominal voltage
Nominal power T-40 /... kW, ca.
T-70 /... kW, ca.
Refrigeration unit
Weight T-40 /... kg, ca.
T-70 /... kg, ca.
Noise level dB(A)
T-40/100
T-65/100
100
500
500
400
1630
770
860
-40/+180
-65/+180
6
2,5
6
3
1400
400
230 V +6 /-10%
1/N, 50Hz
3,5
3
280
300
<55
T-40/200
T-70/200
200
750
650
400
1800
920
1345
-40/+180
-70/+180
4
4
4
4
3500
3000
6
7,2
400
450
<58
T-40/350
T-70/350
350
750
650
720
1800
920
1665
-40/+180
-70/+180
4
3,5
3,5
3,5
3500
3000
6
7,2
500
550
<58
T-40/600
T-70/600
600
850
850
830
1900
1120
1875
-40/+180
-70/+180
3,5
3
3,5
3,5
4000
4000
<± 0,3
400 V +6 /-10%
3/N, 50 Hz
7,2
8,7
550
600
<58
T-40/1000
T-70/1000
1000
900
1000
1100
1950
1270
2245
-40/+180
-70/+180
3
2,5
3
2,5
4000
4000
7,4
8,9
800
850
<58
T-40/1500
T-70/1500
1500
900
1000
1600
1950
1270
2745
-40/+180
-70/+180
2,5
2
3,5
3,5
4000
4000
9,4
10,8
950
1050
<58
air cooled
Options:
add. entry ports Ø 50 mm, 80 mm
and 125 mm
add. shelves
Panoramic window, multiple glazed sized
570 x 710 mm, > 200 ltr. incl. LED-Light
Hand-holes in the door
add. Pt 100 for temperature
measuring on test specimen reversible
to controller function
air dryer system
Mobile design
Temperature protection for test-specimen
water cooled refrigeration unit
CID software for programming
and documentation
variable air speed in the testspace
RS 232 interface changeable to USB
notch
The latest generation with innovative technique and future-oriented design.
CTS-Temperature-/Climatic-Stress-Screening-Chambers
Basic Equipment:
capacitive Multi-Touch-Display in the front
service-friendly capacitive humidity
measurement system
defined keys for elementary functions
of the installation such as start/stop,
fixed-value/automatic operation,
interruption, light, etc.
USB -Connection to save measuring data
on USB Stick
Ethernet – Interface/RS 232 – Interface
2 digital Out, to switch test specimen
ON/OFF
adjustable software-temperature-limiter
min./max.
shelf, stainless steel
entry port Ø 50 mm on the right side
single-hand operated door handle, lockable
Your benefits:
low consumption data
minimum noise level
extremely high temperature change rates
user-friendly operation and programming
uniform operation due to identical
Multi-Touch-Display for all chamber sizes
demineralized water system with level
indicator
temperature measuring with Pt 100 in air
inlet and air outlet
Service-friendly construction
international standards are fulfilled
(CE-Conformity)
Screening Chambers with 5 K/min, 10 K/min and 15 K/min
Test space capacity in Litres: 100 / 200 / 350 / 600 / 1000 / 1500 / 2000
Temperature range: -40° C / +180° C; -70° C / +180° C
Temperature-/Climatic-Stress-Screening-Chambers
Type TS -40/..., CS-40/...
TS -70/..., CS-70/...
Test space litres
Test space dimensions height mm, approx.
width mm, approx.
depth mm, approx.
Overall dimensions height mm, approx.
width mm, approx.
depth mm, approx.
Temperature Tests
Temperature range TS-40 /... CS-40 /... °C
TS-70 /... CS-70 /... °C
Temp. Change rate cooling TS-40 /... CS-40 /... K / min
acc. IEC 60068-3-5 TS-70 /... CS-70 /... K / min
Temp. Chang rate heating TS-40 /... CS-40 /... K / min
acc. IEC 60068-3-5 TS-70 /... CS-70 /... K / min
max. thermal load TS-40 /... CS-40 /... W
at +20°C TS-70 /... CS-70 /... W
Temperature fluctuation K
Climatic Test
Temperature range CS-40 /... CS-70 /... °C
Humidity range CS-40 /... CS-70 /... % r. F.
Dew point range I CS-40 /... CS-70 /... °C
Dew point range II CS-40 /... CS-70 /... °C
Humidity fluctuation I CS-40 /... CS-70 /... % r. F.
Humidity fluctuation II CS-40 /... CS-70 /... % r. F.
Temperature fluctuation CS-40 /... CS-70 /... K
Nominal voltage
Nominal power TS-40 /... kW, approx.
CS-40 /... kW, approx.
TS-70 /... kW, approx.
CS-70 /... kW, approx.
Refrigeration unit
Weight TS-40 /... CS-40 /... kg, approx.
TS-70 /... CS-70 /... kg, approx.
Noise level dB(A)
-70/100-5
100
500
500
400
1630
770
860
-70/+180
8
6
1200
6,5
300<60
-70/100-10
100
500
500
400
1630
770
860
-70/+180
10
10
2000
7,5
air cooled
350<60
-70/200-15
200
750
650
400
1800
920
1345
-70/+180
15
15
5000
10 bis 98
17
650<62
-40/200-5
-70/200-5
200
750
650
400
1800
920
1345
-40/+180
-70/+180
5
6
8
8
3500
3500
9,3
10,4
12
12
air cooled
500
550<58
-40/200-10
-70/200-10
200
750
650
400
1800
920
1345
-40/+180
-70/+180
10
11
12
12
5000
4000
13,4
14,5
16,6
16,6
600
650<62
-40/280-15
280
720
650
615
2080
920
2165
-40/+180
19
16
5000
10 bis 95
15,1
15,1
800
<63
-40/350-5
-70/350-5
350
750
650
720
1800
920
1665
-40/+180
-70/+180
5
5
8
8
3500
3500
9,3
10,4
11,8
11,8
600
650<58
-40/350-10
-70/350-10
350
750
650
720
1800
920
1665
-40/+180
-70/+180
10
10
10
10
5000
5000
13,4
13,4
16,6
16,6
700
750<62
-70/350-15
350
750
650
720
1800
920
1665
-70/+180
15
15
6000
10 bis 98
20,4
18,3
750<62
-40/600-5
-70/600-5
600
850
850
830
1900
1120
1875
-40/+180
-70/+180
6
7
6
6
4500
5000
11
12,1
14,2
14,2
700750
<62
-40/600-10
-70/600-10
600
850
850
830
1900
1120
1875
-40/+180
-70/+180
10
10
10
10
7000
5000
15,5
15,5
13
13
water cooled
800900
<62
-40/500-15
-70/500-15
500
820
850
725
2170
1120
2375
-40/+180
-70/+180
15
15
15
15
7000
8000
24,4
24,4
25,6
25,6
8001000
<68
-40/1000-5
-70/1000-5
1000
900
1000
1100
1950
1270
2245
-40/+180
-70/+180
5
5
6
6
5200
5500
13,3
13,2
16,4
16,4
water cooled
850
900<62
-40/1000-10
-70/1000-10
1000
900
1000
1100
1950
1270
2245
-40/+180
-70/+180
10
10
10
10
8000
7500
20,9
20,9
15,4
15,4
1000
1000<65
-40/810-15
-70/810-15
810
870
1000
900
2230
1270
2645
-40/+180
-70/+180
15
15
15
15
8000
8000
23,7
23,7
27,3
27,3
1100
1800<73
-40/1500-5
-70/1500-5
1500
900
1000
1600
1950
1270
2745
-40/+180
-70/+180
5
5
5
5
5000
5500
13,2
13,2
16,1
16,1
1000
1100<64
-40/1500-10
-70/1500-10
1500
900
1000
1600
1950
1270
2745
-40/+180
-70/+180
10
10
10
10
8000
8000
20,9
20,9
20,2
20,2
1150
1300<70
-40/1250-15
-70/1250-15
1250
870
1000
1400
2230
1270
3142
-40/+180
-70/+180
15
15
15
15
8000
8000
30,8
30,8
38,1
38,1
1350
1500<73
All figures are average values which have been obtained at a temperature of +25°C, without test specimen, without thermal load and without options.
Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.
Options:
add. Entry ports Ø 50 mm,
80 mm und 125 mm
add. Shleves
panoramic window, multiple glazed, sized
570 x 710 mm, < 200 ltr., incl. LED-light
hand-holes in the door
add. Pt 100 for temperature measuring
on test specimen reversible to controller
function
air dryer system
mobile design
air/water cooled refrigeration unit
temperature protection for test specimen
CID software for programming and
documentation
variable air speed in the test space
RS 232 interface changeable to USB
notch
Control: Multi-Touch-Display with
integrated program controller
Test Space:: Stainless steel grade 1.4301
Refrigerants: environmental friendly refrigerants
Humidity system: (only type CS) capacitive measuring
5 K/min. 10 K/min. 15 K/min.
<± 0,3 <± 0,3 <± 0,3
400 V +6% –10%, 3/N, 50 Hz 400 V +6% –10%, 3/N, 50 Hz 400 V +6% –10%, 3/N, 50 Hz
water cooled
+10 bis +95
10 bis 98
+7 bis +94
–10 bis +7
<± 1,5
<± 3
<± 0,3
+10 bis +95
10 bis 98
+7 bis +94
–10 bis +7
<± 1,5
<± 3
<± 0,3
+10 bis +95
10 bis 95
+7 bis +94
–10 bis +7
<± 1,5
<± 3
<± 0,3
CTS GmbH | Lotzenäcker 21 | D-72379 Hechingen | GermanyTel.: +49 (0) 74 71/98 50-0 | Fax: +49 (0) 74 71/98 [email protected] | www.cts-umweltsimulation.de
How to find us:
Exit
Exit
Basic Equipment:
capacitive Multi-Touch-Display in the front
service-friendly capacitive humidity
measurement system
defined keys for elementary functions of
the installation such as start/stop,
fixed-value/automatic operation,
interruption, light, etc.
USB-Connection to save measuring data
on USB Stick
Ethernet – Interface/RS 232 – Interface
2 digital Out, to switch test specimen
ON/OFF
adjustable software-temperature-limiter
min./max.
shelf, stainless steel
entry port Ø 50 mm on the right side
single-hand operated door handle, lockable
Your benefits:
low consumption data
minimum noise level
user-friendly operation and programming
uniform operation due to identical
Multi-Touch-Display for all chamber sizes
demineralized water system with
level indicator
temperature measuring with Pt 100 in
air inlet and air outlet
Service-friendly construction
international standards are fulfilled
(CE-Conformity)
The latest generation with innovative technique and future-oriented design.
CTS-Climatic Test Chambers
Test space capacity in Litres: 100 / 200 / 350 / 600 / 1000 / 1500 / 2000
Temperature range: +10° C / +180° C; -20° C / +180° C
-40° C / +180° C; -70° C / +180° C
CTS-Climatic Test Chambers / series C-40 and C-70
Type
Test space litres Test space dimensions height mm, appr. width mm, appr. depth mm, appr.Overall dimensions height mm, appr. width mm, appr. depth mm, appr.Temperature testsTemperature range C-40 /... °C C-70 /... °CTemp. change rate cooling C-40 /... K / minacc. IEC 60068-3-5 C-70 /... K / minTemp. change rate heating C-40 /... K / minacc. IEC 60068-3-5 C-70 /... K / minmax. thermal load at +20°C C-40 /... W C-70 /... WTemperature fluctuation KClimatic testsTermperature range °CHumidity range % r. F.Dew point range I °CDew point range II °CHumidity fluctuation I, temporally % r. F.Humidity fluctuation II, temporally % r. F.Temperature fluctuation, temporally KNominal voltage
Nominal power C-40 /... kW, appr. C-70 /... kW, appr.Refrigeration unit Weight C-40 /... kg, appr. C-70 /... kg, appr.Noise level dB(A)
C-40/100C-65/100
100500500400
1630770860
-40/+180-65/+180
5233
1200400
-7 bis +7
230 V +6 /-10%1/N, 50 Hz
3,43,4
35038055
C-40/200C-70/200
200750650400
1800920
1345
-40/+180-70/+180
4444
35003000
7,17,1
45050055
C-40/350C-70/350
350750650720
1800920
1665Stangeräte-40/+180-70/+180
43,53,53,5
35003000
7,17,1
500550<58
C-40/600C-70/600
600850850830
190011201875
-40/+180-70/+180
3,53
3,53,5
40004000
400 V +6 /-10%3/N, 50 Hz
8,28,7
550600<58
C-40/1000C-70/1000
1000900
10001100195012702245
-40/+180-70/+180
32,53
2,540004000
8,58,9
800850<58
C-40/1500C-70/1500
1500900
10001600195012702745
-40/+180-70/+180
2,52
3,53,5
40004000
9,210,8
9501050<58
All figures are average values which have been obtained at a temperature of +25°C, without test specimen, without thermal load and without options. Technical data for types +10/–20°C on request.
Options:
add. entry ports Ø 50 mm, 80 mm
and 125 mm
add. shelves
Panoramic window, multiple glazed sized
570 x 710 mm, > 200 ltr. incl. LED-Light
Hand-holes in the door
add. Pt 100 for temperature
measuring on test specimen reversible
to controller function
air dryer system
Mobile design
Temperature protection for test-specimen
water cooled refrigeration unit
CID software for programming
and documentation
variable air speed in the testspace
RS 232 interface changeable to USB
notch
Control: Multi-Touch-Display with
integrated programm controller
Test space: Stainless steel grade 1.4301
Refrigerants: environmental friendly refrigerants
Humidity system: capacitive measuring
Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.
CTS GmbH | Lotzenäcker 21 | D-72379 Hechingen | GermanyTel.: +49 (0) 74 71/98 50-0 | Fax: +49 (0) 74 71/98 [email protected] | www.cts-umweltsimulation.de
air cooled
<± 0,3
+10 bis +95+10 bis +98+7 bis +94-10 bis +7
<± 1,5<± 3
<± 0,3
Basic Equipment:
capacitive Multi-Touch-Display in the front
defined keys for elementary functions
of the installation such as start/stop,
fixed-value/automatic operation,
interruption, light, etc.
USB-Connection to save measuring data
on USB Stick
Ethernet – Interface/RS 232 – Interface
Door with window, incl. LED-light
2 digital Out, to switch test sepcimen
ON/OFF
shelf, stainless steel
entry port, size depending on
chamber type
single-hand operated door handle,
lockable
temperature cycling in cold chamber
(32, 66, 130 Litre)
eco-mode to save energy costs
air dryer system to avoid freezing
in long-time testing
Your benefits:
low consumption data
minimum noise level
user-friendly operation and programming
uniform operation due to identical
Multi-Touch-Display for all chamber sizes
temperature measuring with Pt 100
in air inlet and air outlet
Service-friendly construction
international standards are fulfilled
(CE-Conformity)
compact design with small installation area
The latest generation with innovative technique and future-oriented design. Extreme temperature
changes up to 100 K/min. CTS Thermal-Shock-Test-Chambers comply with current national and
international standards (DIN, BS, MIL). Long term testing up to 3000 cycles.
CTS-Termal-Shock-Test Chambers
Test space capacity in Litres: 32 / 66 / 130 / 350
Temperature range: Hot chamber +50° C / +220° C
Cold chamber -80° C / +100° C
CTS-Thermal-Shock-Test Chambers
Type
Test space litres
Test space dimensions height mm, appr.
width mm, appr.
depth mm, appr.
Overall dimensions height mm, appr.
width mm, appr.
depth mm, appr.
Temperature tests
Temperature range hot chamber °C
cold chamber °C
Adaption time of IC´s < 15 min kg
Changing time sec.
Test load, max. kg
Temperature fluctuation, temporally K
Nominal voltage
Nominal power kW, appr.
Refrigeration units
Weight Cabinet kg, appr.
Noise level dB(A)
entry ports ø mm
TSS-70/32
32
300
360
300
1820 (2415*)
820
1325
+50/+220
-80/+100
2,5
<10
10
±1
400 V +6 /-10%
3/N, 50 Hz
9,7
air cooled
650
58
50
TSS-70/66
66
300
420
525
1820 (2415*)
880
1550
+50/+220
-80/+100
2,5
<10
22
±1
400 V +6 /-10%
3/N, 50 Hz
9,7
air cooled
700
58
80
TSS-70/130
130
410
480
660
1820 (2525*)
940
2335
+50/+220
-80/+100
10
<10
50
±1
400 V +6 /-10%
3/N, 50 Hz
19
water cooled
950
<60
125
TSS-70/350
350
610
850
680
2450 (3200*)
2160 (2300**)
2200
+50/+220
-80/+100
25
<10
110
±1
400 V +6 /-10%
3/N, 50 Hz
33
water cooled
2500
<68
125
All figures are average values which have been obtained at a temperature of +25°C, without test specimen, without thermal load and without options. (* = height with spindle ** = width with spindle drive)
Control: Multi-Touch-Display with integrated programm controller
Test space: Stainless steel grade 1.4301
Refrigerants: environmental friendly refrigerants
Options:
add. shelves and protection for the basket
increased temperature range in hot
chamber to +250°C (for 130 ltr.)
temerature protection for test specimen
add. Pt 100 for temperature measuring on
test specimen
CID software for programming and
documentation
Water cooled refrigeration unit for
TSS -70/32 and TSS -70/66
Air cooled refrigeration unit for
TSS -70/130 and TSS -70/350
RS 232 interface changeable to USB
Add. entry ports
Higher test load
Separate machine unit, incl. control
unit (350 ltr.)
CTS GmbH | Lotzenäcker 21 | D-72379 Hechingen | GermanyTel.: +49 (0) 74 71/98 50-0 | Fax: +49 (0) 74 71/98 [email protected] | www.cts-umweltsimulation.de
Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.
CTS-Pharma-Climatic-Test-Chambers
Test Space Capacity in Litres: 600 / 1200
Temperature Range: +10° C / +50 °C
Humidity range: 10 - 90% r.H.
Dew Point Range I: +7° C to +45 °C
II:
for long-term stability test with
highest testing precision.
Type CP 10/600 & Type CP 10/1200
Your Benefits:
Use of environmentally friendly materials
and refrigerants
Simple user-friendly operation
Own CTS-controller optimized to CTS-
systems
Internal and external material in stainless
steel for easy cleaning
Standard-Version of the Productline “CP”:
Capacitive measuring system
Casing in stainless-steel
Door lockable
Interface RS 232
3 RVS shelves
Entry port ø 50 mm
Multicolour touchpanel; 32 Bit Controller
Low noise refrigerating unit
Potential-free contact for malfunction signal
Options: door with window
CTS-Pharma-Climatic-Test-ChambersSerie CP600 / 1200 Ltr.
All figures are average values which have been obtained at a temperature of +25°C, without test specimens, without thermal load and without accessories.
Design:Control: Microprocessor control and monitoring systemTest space: Stainless steel nr. 1.4301Casing: Stainless steel nr. 1.4301Refrigerants: Chloride free, hermetically sealedHumidity system: Capacitive measuring
Options: add. entry ports ø 50 mm temperature protection for test-specimen add. shelves CID software for programming and documentation add. Pt 100 for temperature measuring on test specimen alternative extended temperature range down to ± 0 °C reversible to controller function reservoir for humidification water RS 232 interface changeable to USB door with fullsize window (reduced dew-point-range < +30°C)
Other chamber sizes and options on request.
We reserve the right to make alterations due to technical development.
Type CP 10/600 CP 10/1200 Test space Litres, appr. 600 1200 Test space dimensions hight mm, appr. 1369 1369 width mm, appr. 594 2 x 540 depth mm, appr. 673 673 Overall dimensions hight mm, appr. 2090 2090 width mm, appr. 733 1466 depth mm, appr. 803 803
Temperature testTemperature range °C +10 / +50 +10/+50 Temperature fluctuation K ±0,5 temporally ±0,5 temporally
Cliamtic testTemperature range °C +10 / +50 +10 / +50Humidity range % RH 10 / 90 ±10 / 90Dew point range °C +7 / +45 and -5 / +7 +7 / +45 and -5 / +7 Humidity fluctuation % RH ±1 / 3 ±1 / 3Temperature fluctuation K ±0,5 temporally ±0,5 temporallyNominal voltage 230 V +6 / -10%, 1/N, 50 Hz 230 V +6 / -10%, 1/N, 50 HzNominal power kW, appr. 1,6 2,0Refrigeration unit aircooled aircooledWeight kg, appr. 150 200
CTS GmbH Lotzenäcker 21 72379 Hechingen Germany
Tel: 0 74 71/98 50-0 Fax: 0 74 71/98 50-23
E-Mail: [email protected] www.cts-umweltsimulation.de
CTS Nederland BV ▲ Amperestraat 8-06 ▲ 4004 KB Tiel ▲ The Netherlands
Tel.: +31(0)344-607917 ▲ Fax: +31(0)344-607908
E-mail: [email protected] ▲ www.ctsnederland.nl
Citrotek EMC-Temperature Test Chambers (bench top version)
Multicolour touch panel / 32 Bit Controller Minimum noise level RS 232 interface / Ethernet interface Potential free contact for malfunction signal Single-hand operated door handle, lockable Entry module on the right side EMC damping up to 82dB, better that 55dB on averaged in the range from 0,5 to 6 GHz
Your benefits: Test space capacity in litres: 25 / 50
Temperature range: -40° C / +105° C; -65° C / +105° C
Complies with current CE and EMC regulation Use of environmentally friendly materials and refrigerants Service-friendly construction simple user-friendly operation Optimized parameters for highest testing precision
Based on CTS latest chamber generation with innovative technique and future-oriented design. Standard-Version of the product line “T-XX/XXX-EMC”:
EMC-Temperature Test Chambers (bench top version) series T-40 and T-65 25 and 50 Ltr.
Type T -40/25 T-40/50 T -65/50
Test space litres appr. 25 50 50 Test space dimensions height mm, appr. 300 400 400
width mm, appr. 350 400 400 depth mm, appr. 240 320 320
Overall dimensions height mm, appr. 860 980 980 width mm, appr. 510 560 560 depth mm, appr. 580 660 840
Design bench top cabinet
Temperature tests Temperature range °C -40/+105 -40/+105 -65/+105 Temp. change rate cooling T-40/... K/min 6,5 5 acc IEC 60068-3-5 T-70/... K/min 4 Temp. change rate heating K/min 8 5 5 acc IEC 60068-3-5 max. thermal load at +20° C W 400 400 400 Temperature fluctuation K ± 0,5 / ± 1 temporally Nominal voltage 230 V +6% -10%, 1/N, 50 Hz Nominal power kW, appr. 1,9 1,9 2,3 Refrigeration units air cooled Weight kg, appr. 90 130 160
All figures are average values which have been obtained at a temperature of +25°C, without test specimens, without thermal load and without accessories. The max. thermal load and the cooling/heating gradients are listed with a blank entry module without any lead through. The maximum test temperature can been limited to 85°C, as some lead through will be damaged above this temperature.
Design: Control: Microprocessor control and monitoring system Test space: Stainless steel grade 1.4301 Refrigerants: Chloride free, hermetically sealed
Options:
Entry module in left side too air dryer system Rack incl. 1 shelf Temperature protection for test-specimen Table with height 330 or 515 mm CID software for programming and documentation Sub-zero module heater variable air speed in the test space USB, D-sub, DC and SMA lead through RS 232 interface changeable to USB add. Pt 100 for temperature measuring USB - interface on test specimen alternative reversible to controller function
Other chamber sizes and Options on request.
We are producing a lot of different entry modules, based on customer unique requirements: 9 & 25 pole D-sub connector, SMA 24, single pole DC lead-troughs and a filtered USB2.0 lead-trough, fitted with a female plug type A and B. The USB including the “sub-zero heater” option, which maintains a temperature on the outside of the module, between +15° and +25°C and are preventing water and ice to build up, due to the thermal conductivity of the USB lead-trough. We reserve the right to make alterations due to technical development. Ver. 1.04/4/2015
Citrotek ApS Jespervej 50 3400 Hillerød Denmark
Tel.: +45 4824 3656 Fax: +45 4824 3628
E-Mail: [email protected] www.citrotek.dk
Standards: NT E
LEC
030
Displays all connected units (chamber
names and status).
Displays all analogue and digital channels
for any selected unit.
Displays status information for the selec-
ted unit (automatic or manual operation,
error reports).
Dynamic contextual screen set up – elimi-
nation of unnecessary or confusing
elements.
Displays all functions via symbols and
menu bars. All symbols also contain a tool
text-description.
Short but significant reports listing for all
units.
The chamber name is easily editable to
meet requirements.
Language can be changed during running
time to either German, English or Czech.
Help as PDF format.
CTS-Software CID-Pro 4.02
Operating system has never been so
simple and user-friendly!
The new CID-Pro 4.02 is impressive for its easy and self-explanatory operation. All functions are
menu driven and shown as symbols. In addition, substantial amounts of information from the
unit are displayed and can be partially edited.
Status Overview
Editor
Create your test cycle programs simply and easily. The new extended CID-Pro 4.02-Editor has
many helpful functions making its use even easier, e.g. copy and past lines or line-blocks, calcu-
late gradients exactly or save programs as template-modules.
Create, change or delete the test cycle
programs.
Define value lines, loops, conditional
jumps or subprograms in the test program.
Set the time base of a program:
Seconds, minutes or hours.
Zoom a specific area to set a value more
accurately.
Display all functions via symbols and menu
bars. All symbols contain a tool text-
description.
Detailed information of all channel values
for the selected lines.
Copy lines or whole blocks and paste
them back again.
Create or shift a point in the graphics with
double click on the new point.
Loads the last test program opened.
Zoom to 20 levels.
Save programs as templates that can be
pasted back as modules.
Define a fixed gradient for a point e.g.
-5K/min cooling or 5K/min heating.
PDF printout
Graphical measurement data evaluation
A record of the test cycle program can be created storing all analogue and digital channels. This
data can be evaluated and the results imported into Microsoft® Excel if required.
Display complete measurement results.
Hide channels which are not to be dis-
played.
Difference and duration can be calculated
(evaluation with two cursors on the graph).
Select real time displays (date and time) or
relative information (e.g. minutes).
Zoom a selected area to carry out more
accurate evaluations.
The scaling of analogue channels can
be displayed on the right or left in the
graphic zone.
Display all functions via symbols and menu
bars. All symbols contain a tool text-
description.
Also display the cursor in the digital
channels.
Standard-configuration for the display of
analogue and digital channels is selectale:
The first 4 analogue and 4 digital channels
have standard-set-actual-colours.
The last measured results opened are
loaded.
Zoom to 20 levels.
Extended search for measuring files.
Measured files for the same configurations
can be combined.
Optimized Microsoft® Excel export func-
tion with user changeable options.
PDF printout or logging
Show measurement results in a table
(complete or within cursor positions).
CTS GmbH Lotzenäcker 21 72379 Hechingen Germany
Tel.: 0 74 71/98 50-0 Fax: 0 74 71/98 50-23
e-mail: [email protected] www.cts-umweltsimulation.de
Visualising
With the new menus, there is the option to
visually display the layout of your units with
site layout background photos and pictures
of the individual setups. Units can be confi-
gured with user-defined sizes, position and
appearance.
Key information is displayed when the cursor
is moved over a chamber.
Networking
Communication to the setup is freely confi-
gurable through RS232, RS485 or a network.
Additionally, an online monitoring function is
provided for other computers on the network.
Special menus for Temperature
Shock-Test-Cabinets
A particularly clear display of the configura-
tion with the special shock-test menu. The
heating chamber, lower cold chamber or
lift cage temperature – all information at a
glance.
With the shock test editor, standard shock
test programs can be easily created.
Supporting operating systems
Microsoft Windows 8, 7, Vista, XP (32- and
64 bit), Windows 2000 + SP3