    Computation of lc.s.

    Outflow through outlet openings (scurgerea prin orificii)

    A small outlet opening is considered two tanks having different manometric pressure (presiuni

    manometrice diferite) as it can be seen in the figure:

    The section 1 of the Bernoullis equation is at free level of the first tank while section 2 is at the

    exit from the outlet, the Bernoullis equation has the form:

    from which the speed v2 can be computed:

    If (V=speed coefficient), the speed is given by general form:

    In the case of free exit from outlets (iesire libera din rezervor) we have 2=0;H2=0 and:

    If further on the free surface of the first tank only the a.p. (atmospheric pressure) acts we have:

    If we want to compute the flow (debitul) of the exit, we have to introduce first the notion of

    shrinkage coefficient (coefficient de contractie)=wc/w, where:

  • 8/3/2019 curs6-eng

    2/5

    w=cross section of the outlet

    wc=cross section of the liquid jet (see figure)

    The flow (debitul) is given by:

    The parameter =v is called coefficient of discharge (coefficient de debit) and:

    Where, usual values of the above coefficients are:

    v= 0,960,99

    = 0,620,64

    = 0,600,62Computation of sh.s.

    Water supply networks (w.s.n.) (de distributie a apei)

    The w.s.n. are system that bring the water (drinking and industrial) to each individual consumer

    (residential buildings, schools, factories, agricultural units, etc.). There are two types w.n.s.

    which differ from each other by their operational system, economical and hydraulic computation:

    - ring network (retea inelara)

  • 8/3/2019 curs6-eng

    3/5

    - open network (retea ramificata,retea deschisa sau retea arborescenta)

    Comparison

    1. For the same number of consumers, the total length of pipes is much smaller in the caseof open network than in the case of ring networks;

    2. The hydraulic computation is simpler in the case of open networks than in the case ringnetwork;

    3. From the point of view of their functionality the ring network are superior to opennetworks. For instance in the case of ring network each consumer is supplied from at

    least two parts while in the case of open networks one consumer gets its flow from one

    part only.

    As it can be seen from above drawing, if in section A damage (avarie, defectiune) is produced, inthe case of open networks all the consumers located downstream ( in aval) are not supplied. In

    the same situation, in the case of ring networks, only the consumers located in the immediate

    neighboring of the damage pint A will not be supplied, while the rest of consumers are normally

    supplied. This situation leads to specific legislation concerning the water supply networks: the

    open networks are used only for non-important places, agricultural consumers, etc. In the case of

    towns and etc. the ring networks are compulsory.

    Computation of open Networks

    Take a simple open network with two pitchers (doua ramificatii) and three consumers. In the

    case of more elaborated open network only the computation volume increases, the computation

    principles are the same.

  • 8/3/2019 curs6-eng

    4/5

    The hydraulic computation from the above open networks is presented.

    Given:

    - The network geometry (lengths, coordinates).- The necessary flows (debite necesare) for each consumer. It is a specific value depending

    on the number of people and the required level of comfort (comfort tehnic-edilitar)

    - The height of equipment inside the buildings. It imposes the necessary pressure (p/)Required:

    - the diameters of the pipes for each pitches (tronson, ramificatie);-

    the pressure in the supplying tank (rezervor de alimentare)The practical solving of this typical dimensioning problem depends on the local relief:

    - a mountain type relief;- a flat plane relief.

    In the case of a mountain type relief (as in Cluj for instance) we can build the water tank at the

    required level using the local relief (on the top of a hill for instance). It is the case of an efficient

    network (small diameters). The procedure is as follows:

    - the terminal points of the network are considered and their pressure line ( liniapiezometrica sau presiunea de serviciu) is computed (see laboratory classes);

    - using the criteria of efficient speed ve (viteza economica), the pipe diameter near theterminal point is computed using the relation:

    - a commercial (industrially manufactured) diameter immediately smaller than thecomputed on is chosen;

    - the pressure line (linia piezometrica) can now be computed and therefore the necessarypressure in section i. In the following drawing the variation of pressure along the

    branches up to the tank is presented.

    In this way, using the most efficient diameter each consumer us supplied with the necessary flow

    and under at least the required pressure.

  • 8/3/2019 curs6-eng

    5/5

    In the case of flat plane relief, the water tank has to be artificially located at the required level.

    But due to specific construction problems this level can not be at big heights. Starting with the

    necessity of assuring the required pressure at the terminal points (critical points), and following

    the way up to the water tank, the distributed head losses are found to be smaller than the

    precedent case. Using Sevelevs formula for head losses, the parameters0 (coefficient de

    rezistenta hidraulica = exchange coefficient) is computed

    With =1 and knowing lij, Qijand hd, from given tables (see laboratory classes) the commercial

    neighboring diameters can be found. To ensure the required pressure the bigger will be chosen

    from the table.

    Concluding remarks: in the second case (flat plane) the diameters are bigger than in the case of

    mountain type relief.