Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
RESIDENTIAL ROOFING
Metdek 500
0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: [email protected]
00 / 24 COVER SHEET01 / 24 ROOF RIDGE02 / 24 SAWTOOTH RIDGE03 / 24 SAWTOOTH EAVE04 / 24 ROOF VALLEY05 / 24 ROOF - CHANGE PITCH06 / 24 EAVE WITH METALLINE FASCIA07 / 24 EAVE WITH INTERNAL GUTTER BRACKET08 / 24 EAVE WITH SNOW STRAP09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET11 / 24 BARGE WITH PROFILED CLADDING12 / 24 BARGE OVERHANG13 / 24 PARAPET WITH TRANSVERSE APRON14 / 24 TRANSVERSE APRON15 / 24 PARALLEL APRON16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION17 / 24 OVER 85mm DIAMETER PIPE PENETRATION18 / 24 3D RIDGE TO BARGE JUCTION19 / 24 3D DUTCH GABLE20 / 24 3D APRON21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION22 / 24 3D CHIMNEY PENETRATION23 / 24 3D RIDGE/BARGE FLASHINGS24 / 24 3D DUTCH GABLE FLASHINGS
DETAIL LIST
* METDEK 500 MIN. ROOF PITCH = 3°
PRE-FINISHED RIDGE CAP FLASHING
STOPENDS TO ROOF CLADDING
ROOF FRAMING
PURLIN
METALCRAFT METDEK 500 ROOFING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
BUILDING PAPER SHOWN DASHED
15.0
0°
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
X
NOTCHED EDGE DRESSED OVER METDEK 500 RIBS
5mm
GAP
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mmX
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
ROOF RIDGE
01 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
NOTCHED EDGE DRESSED OVER METDEK 500 RIBS
STOPENDS TO ROOF CLADDING
BUILDING PAPER SHOWN DASHED
PURLIN
PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE METALCRAFT METDEK 500 CLIP
SYSTEM WITH SPIRAL SHANK NAILS
ROOF OR WALL FRAMING
TIMBER PACKER
FASCIA BOARD
TIMBER PACKER
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
METALCRAFT METDEK 500 ROOFING
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
15.0
0°
Z
X
HEMMED EDGE
PRE-FINISHED SAWTOOTH RIDGE CAP FLASHING
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
MIN. 70mm
X
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE -PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mm
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
X
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
SAWTOOTH RIDGE
02 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
TIMBER FASCIA
SOFFIT LINING
PRE-FINISHED SAWTOOTH RIDGE CAP FLASHING
ROOF FRAMING
15.0
0°
X
Z
PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
HEMMED EDGE
NOTCHED EDGE DRESSED OVER METDEK 500 RIBS
STOPENDS TO ROOF CLADDING
BUILDING PAPER SHOWN DASHED
PURLIN
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
METALCRAFT METDEK 500 ROOFING
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
MIN. 70mm
X
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE -PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mm
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
X
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
SAWTOOTH EAVE
03 / 242014
ROOF FRAMING
PURLIN
METALCRAFT METDEK 500 ROOFING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
BUILDING PAPER CONTINUOUS UNDER GUTTER IF COPPER BASED TREATMENTS ARE USED. SHOWN DASHED
VALLEY BOARD
PREFINISHED VALLEY GUTTER
MIN
. 50m
m
CC
B : CLEARANCE BETWEEN ROOFING
A : OVERALL VALLEY GUTTER WIDTH
MIN
. 20mm
SITUATION 1
MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°
MIN. 250mm
MIN. 50mm
MIN. 80mm
SITUATION 2
MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°
160mm - 249mm
MIN. 40mm
MIN. 60mm
A
B
C
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND E2 FOR FURTHER INFORMATION.
* ROOF PITCH FOR VALLEYS AS PER E2.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
ROOF VALLEY
04 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
PURLIN
METALCRAFT METDEK 500 ROOFING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
PURLIN
ROOF FRAMING
STOPENDS TO ROOF CLADDING
PRE-FINISHED CHANGE OF ROOF PITCH FLASHING
BUILDING PAPER CONTINUOUS OVER FLASHING SHOWN DASHED
BUILDING PAPER CONTINUOUS UNDER FLASHING SHOWN DASHED
45.0
0°10
.00°
MIN. 250mm
CLEARANCE
MIN. 10mm
X
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
NOTCHED EDGE DRESSED OVER METDEK 500 RIBSMETALCRAFT METDEK 500 ROOFING
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mmX
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
ROOF - CHANGE PITCH
05 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
METALCRAFT METDEK 500 ROOFING
PRE-FINISHED EAVE FLASHING
BUILDING PAPER SHOWN DASHED
METALLINE™ FASCIA
FASCIA BRACKET
SOFFIT LINING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
METALLINE™ QUAD GUTTER
METALLINE™ QUAD GUTTER OVERSTRAP
TIMBER ROOF FRAMING
15.00°
OVE
RLA
P
MIN
. 35m
m
OR AS REQUIREDMIN. 50mm
MIN. 125 mm
SPRING CLIP
TIMBER PURLIN
EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE WITH METALLINE FASCIA
06 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
TIMBER FASCIA
METALLINE™ QUAD GUTTER
METALLINE™ QUAD GUTTER INTERNAL BRACKET
15.00°
SOFFIT LINING
TIMBER ROOF FRAMING
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
OR AS REQUIREDMIN. 50mm
MIN. 125 mm
OVE
RLA
P
MIN
. 35m
mTIMBER PURLIN
PRE-FINISHED EAVE FLASHING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
STST OR GALV. FLAT HEAD NAIL OR FLASHING
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE WITH INTERNAL GUTTER BRACKET
07 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
TIMBER FASCIA
METALLINE™ QUAD GUTTER
METALLINE™ QUAD GUTTER INTERNAL BRACKET
15.00°
SOFFIT LINING
TIMBER ROOF FRAMING
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
OVE
RLA
P
MIN
. 35m
m
TIMBER PURLIN
PRE-FINISHED EAVE FLASHING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
OR AS REQUIREDMIN. 50mm
MIN. 125 mm
SNOW STRAP AS REQUIRED
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
EAVE WITH SNOW STRAP
08 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
TIMBER PACKER
FASCIA BOARD TIMBER PACKER
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
ROOF FRAMING
15.00°
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
OVE
RLA
P
MIN
. 35m
mTIMBER PURLIN
PRE-FINISHED EAVE FLASHING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
OR AS REQUIREDMIN. 50mm
MIN. 125 mm
QUARTER ROUND GUTTER
QUARTER ROUND GUTTER INTERNAL BRACKET
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
FLUSH EAVE WITH INTERNAL GUTTER BRACKET
09 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
TIMBER PURLIN
PRE-FINISHED EAVE FLASHING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
15.00°
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
TIMBER PACKER
FASCIA BOARD TIMBER PACKER
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
ROOF FRAMING
OVE
RLA
P
MIN
. 35m
m
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
OR AS REQUIREDMIN. 50mm
MIN. 125 mm
QUARTER ROUND GUTTER
QUARTER ROUND GUTTER EXTERNAL BRACKET
PRE-FINISHED 8g WAFER-TEK SCREW
EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
FLUSH EAVE WITH EXTERNAL GUTTER BRACKET
10 / 242014
TIMBER PACKER
BARGE BOARD
PRE-FINISHED BARGE FLASHING
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
PURLIN
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE
ROOF FRAMING
TIMBER PACKER
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGEHEMMED EDGE
ZPRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
Y
5mm
GAP
PRE-FINISHED SELF DRILLING/TAPPING SCREW WITH RUBBER WASHER
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
AT LEAST TWO CRESTS
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 70mm
Y
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METDEK 500)
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METDEK 500)
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Y
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 2
BARGE WITH PROFILED CLADDING
11 / 242014
PRE-FINISHED BARGE FLASHING
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
FLY RAFTER
BARGE BOARD
BUILDING PAPER SHOWN DASHED
PURLIN
SOFFIT LINING
PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE
Z
PRE-FINISHED SELF DRILLING/TAPPING SCREW WITH RUBBER WASHER
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
HEMMED EDGE
Y
5mm
GAP
METALCRAFT METDEK 500 ROOFING
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
AT LEAST TWO CRESTS
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 70mm
Y
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 90mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METDEK 500)
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METDEK 500)
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Y
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 2
BARGE OVERHANG
12 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
15.0
0°
MIN
. 5.0
0°
GN
L
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
TIMBER PACKER
BARGE BOARD
WEATHERBOARDS ON CAVITY
BUILDING PAPER SHOWN DASHED
PRE-FINISHED PARAPET CAP FLASHING
TIMBER PACKER
BUILDING PAPER TO PROVIDE SEPARATION OF METAL CAPPING AND TIMBER SHOWN DASHED
TIMBER PURLIN
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
WALL FRAMING ROOF FRAMING
PRE-FINISHED APRON FLASHING
TIMBER NOG FOR FIXING APRON FLASHING
CONTINUOUS TIMBER PACKING
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
PRE-FINISHED SELF DRILLING / TAPPING SCREW WITH RUBBER WASHER
PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE
Z
NOTCHED EDGE DRESSED OVER METDEK 500 RIBS
STOPENDS TO ROOF CLADDING
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
MIN. 70mm
G
N
L
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm
MIN. 90mmPLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
25mm
MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)
MIN. 200mm
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
G
N
L
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
PARAPET WITH TRANSVERSE APRON
13 / 242014
* METDEK 500 MIN. ROOF PITCH = 3°
15.0
0°
GN
L
STOPENDS ROOF CLADDING
ROOF FRAMING
WALL FRAMING
PVC CAVITY CLOSER
WEATHERBOARDS ON CAVITY
CANT STRIP PACKER
NOG FOR FIXING APRON FLASHING
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
METALCRAFT METDEK 500 ROOFING
BUILDING PAPER SHOWN DASHED
PRE-FINISHED APRON FLASHING
BUILDING PAPER OVER FLASHING SHOWN DASHED
BUILDING PAPER SHOWN DASHED
PURLIN
NOTCHED EDGE DRESSED OVER METDEK 500 RIBS
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)
G
N
L
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
25mm
MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)
MIN. 200mm
G
N
L
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
TRANSVERSE APRON
14 / 242014
PURLIN
GN
PRE-FINISHED APRON FLASHING
WEATHERBOARDS ON CAVITY
CANT STRIP PACKER
BUILDING PAPER OVER FLASHING SHOWN DASHED
STST OR GALV. FLAT HEAD NAIL FOR FIXING
NOG FOR FIXING APRON FLASHING
PVC CAVITY CLOSER
METALCRAFT METDEK 500 ROOFING
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
M
WALL FRAMING
BUILDING PAPER SHOWN DASHED
ROOF FRAMING
5mm
GAP
PRE-FINISHED SELF DRILLING/TAPPING SCREW WITH RUBBER WASHER
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°
MIN. 35mm
MIN. 75mm
AT LEAST TWO CRESTS
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
AT LEAST TWO CRESTS
G
N
M
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
AT LEAST TWO CRESTS
PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METDEK 500)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
25mm
MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)
TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METDEK 500)
G
N
M
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 2
PARALLEL APRON
15 / 242014
THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.3° and MAX. 45°- PIPE DIAMETER MAX. 85mm 15.00°
* MIN. 10° FOR PIPE PENETRATION
METALCRAFT METDEK 500 ROOFING
EPDM FLEXIBLE CONE SLEEVE MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012.
BUILDING PAPER SHOWN DASHED
METALCRAFT METDEK 500 ROOFING
PIPE (PIPE DIAMETER MIX. 85mm)
EPDM FLEXIBLE CONE SLEEVE
BUILDING PAPER SHOWN DASHED
MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012.
TIMBER PURLIN
ROOF FRAMINGMETALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
TIMBER PURLIN
ROOF FRAMING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 5
MAX. 85mm DIAMETER PIPE PENETRATION
16 / 242014
THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.3°- PIPE DIAMETER OVER 85mm AND MAX. 500mm- PIPE TO BE POSITIONED AS CLOSE TO ROOF RIDGE AS POSSIBLE
L
PRE-FINISHED SOAKER FLASHING UNDER PRE-FINISHED ROOF RIDGE CAP FLASHING
PIPE (PIPE DIAMETER OVER 85mm AND MAX. 500mm)
EPDM FLEXIBLE CONE SLEEVE
METALCRAFT METDEK 500 ROOFING
MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012. PRE-FINISHED SOAKER FLASHING WITH
PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT METDEK 500 ROOFING
PURLINROOF FRAMING
PRE-FINISHED ROOF RIDGE CAP FLASHING
METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS
EPDM FLEXIBLE CONE SLEEVE
NOGS BETWEEN PURLINS FOR PENETRATION
5mm
GAP
5mm
GAP
PURLIN
BUILDING PAPER SHOWN DASHED
ROOF FRAMING
X
M
15.00°
* MIN. 10° FOR PIPE PENETRATION
REFER TO SHEET NO. 14/24 TRANSVERSE APRON
REFER TO SHEET NO. 16/24 PARALLEL APRON
REFER TO SHEET NO. 01/24 ROOF RIDGE
L
M
X
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 5
OVER 85mm DIAMETER PIPE PENETRATION
17 / 242014
PRE-FINISHED RIDGE CAP FLASHING
METALCRAFT METDEK 500 ROOFING
PRE-FINISHED BARGE FLASHING
PURLIN
ROOF FRAMING
FASCIA BOARD
WALL CLADDING ON CAVITY
WALL FRAMING
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D RIDGE TO BARGE JUCTION
18 / 242014
PRE-FINISHED RIDGE FLASHING
METALCRAFT METDEK 500 ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FOR MINIMUM ROOF OVERHANG
PRE-FINISHED BARGE FLASHING
PRE-FINISHED APRON FLASHING
PRE-FINISHED HIP FLASHING
GUTTER
FASCIA BOARD
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
WALL CLADDING ON CAVITY
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D DUTCH GABLE
19 / 242014
GUTTER
METALCRAFT METDEK 500 ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FOR MINIMUM ROOF OVERHANG
WALL CLADDING ON CAVITY
PRE-FINISHED APRON FLASHING WITH HEMMED EDGE
PRE-FINISHED APRON DIVERTER
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
WALL CLADDING ON CAVITY
FASCIA BOARD
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D APRON
20 / 242014
PRE-FINISHED SOAKER FLASHING
EPDM FLEXIBLE CONE SLEEVE
MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012.
PRE-FINISHED ROOF RIDGE FLASHING
PIPE (DIAMETER OVER 85mm DIAMETER)
METALCRAFT METDEK 500 ROOFING
PRE-FINISHED ROOF BARGE FLASHING
PRE-FINISHED SOAKER FLASHING LINE UNDER PRE-FINISHED ROOF RIDGE FLASHING
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D OVER 85mm DIAMETER PIPE PENETRATION
21 / 242014
METALCRAFT METDEK 500 ROOFING TURN DOWN INTO GUTTER
PRE-FINISHED APRON FLASHING
WALL CLADDING ON CAVITY
PREFINISHED VALLEY GUTTER
PURLIN
PRE-FINISHED SOAKER FLASHING
VALLEY BOARD
ROOF FRAMING
MIN
. 110
mm
UPS
TAN
D
MIN. 110mm UPSTAND PRE-FINISHED 1.6mm ALUMINIUM WELDED SOAKER FLASHING
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
DIVERTER FLASHING ON UPPER SIDE OF CHIMNEY
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D CHIMNEY PENETRATION
22 / 242014
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D RIDGE/BARGE FLASHINGS
23 / 242014
OPTION 1
RIDGE CAP FLASHING
ADDITIONAL SADDLE FLASHING
BARGE FLASHING
RIDGE CAP FLASHING
ADDITIONAL SADDLE FLASHING
BARGE FLASHING
OPTION 2
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.
(3) PRE-FINISHED 3D SADDLE FLASHING
(2) PRE-FINISHED APRON FLASHING
(1) PRE-FINISHED HIP FLASHING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL ROOFINGMetdek 500
RRMD500 ScaleDate Sheet
3D DUTCH GABLE FLASHINGS
24 / 242014
* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.