25
RESIDENTIAL ROOFING Metdek 500 0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] RRMD500 00 / 24 COVER SHEET 01 / 24 ROOF RIDGE 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH INTERNAL GUTTER BRACKET 08 / 24 EAVE WITH SNOW STRAP 09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET 10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET 11 / 24 BARGE WITH PROFILED CLADDING 12 / 24 BARGE OVERHANG 13 / 24 PARAPET WITH TRANSVERSE APRON 14 / 24 TRANSVERSE APRON 15 / 24 PARALLEL APRON 16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION 17 / 24 OVER 85mm DIAMETER PIPE PENETRATION 18 / 24 3D RIDGE TO BARGE JUCTION 19 / 24 3D DUTCH GABLE 20 / 24 3D APRON 21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION 22 / 24 3D CHIMNEY PENETRATION 23 / 24 3D RIDGE/BARGE FLASHINGS 24 / 24 3D DUTCH GABLE FLASHINGS DETAIL LIST

C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

RESIDENTIAL ROOFING

Metdek 500

0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

00 / 24 COVER SHEET01 / 24 ROOF RIDGE02 / 24 SAWTOOTH RIDGE03 / 24 SAWTOOTH EAVE04 / 24 ROOF VALLEY05 / 24 ROOF - CHANGE PITCH06 / 24 EAVE WITH METALLINE FASCIA07 / 24 EAVE WITH INTERNAL GUTTER BRACKET08 / 24 EAVE WITH SNOW STRAP09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET11 / 24 BARGE WITH PROFILED CLADDING12 / 24 BARGE OVERHANG13 / 24 PARAPET WITH TRANSVERSE APRON14 / 24 TRANSVERSE APRON15 / 24 PARALLEL APRON16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION17 / 24 OVER 85mm DIAMETER PIPE PENETRATION18 / 24 3D RIDGE TO BARGE JUCTION19 / 24 3D DUTCH GABLE20 / 24 3D APRON21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION22 / 24 3D CHIMNEY PENETRATION23 / 24 3D RIDGE/BARGE FLASHINGS24 / 24 3D DUTCH GABLE FLASHINGS

DETAIL LIST

Page 2: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

PRE-FINISHED RIDGE CAP FLASHING

STOPENDS TO ROOF CLADDING

ROOF FRAMING

PURLIN

METALCRAFT METDEK 500 ROOFING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

BUILDING PAPER SHOWN DASHED

15.0

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

X

NOTCHED EDGE DRESSED OVER METDEK 500 RIBS

5mm

GAP

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

ROOF RIDGE

01 / 242014

Page 3: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

NOTCHED EDGE DRESSED OVER METDEK 500 RIBS

STOPENDS TO ROOF CLADDING

BUILDING PAPER SHOWN DASHED

PURLIN

PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE METALCRAFT METDEK 500 CLIP

SYSTEM WITH SPIRAL SHANK NAILS

ROOF OR WALL FRAMING

TIMBER PACKER

FASCIA BOARD

TIMBER PACKER

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

METALCRAFT METDEK 500 ROOFING

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

15.0

Z

X

HEMMED EDGE

PRE-FINISHED SAWTOOTH RIDGE CAP FLASHING

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE -PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

SAWTOOTH RIDGE

02 / 242014

Page 4: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

TIMBER FASCIA

SOFFIT LINING

PRE-FINISHED SAWTOOTH RIDGE CAP FLASHING

ROOF FRAMING

15.0

X

Z

PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

HEMMED EDGE

NOTCHED EDGE DRESSED OVER METDEK 500 RIBS

STOPENDS TO ROOF CLADDING

BUILDING PAPER SHOWN DASHED

PURLIN

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

METALCRAFT METDEK 500 ROOFING

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE -PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

SAWTOOTH EAVE

03 / 242014

Page 5: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

ROOF FRAMING

PURLIN

METALCRAFT METDEK 500 ROOFING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

BUILDING PAPER CONTINUOUS UNDER GUTTER IF COPPER BASED TREATMENTS ARE USED. SHOWN DASHED

VALLEY BOARD

PREFINISHED VALLEY GUTTER

MIN

. 50m

m

CC

B : CLEARANCE BETWEEN ROOFING

A : OVERALL VALLEY GUTTER WIDTH

MIN

. 20mm

SITUATION 1

MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°

MIN. 250mm

MIN. 50mm

MIN. 80mm

SITUATION 2

MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°

160mm - 249mm

MIN. 40mm

MIN. 60mm

A

B

C

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND E2 FOR FURTHER INFORMATION.

* ROOF PITCH FOR VALLEYS AS PER E2.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

ROOF VALLEY

04 / 242014

Page 6: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

PURLIN

METALCRAFT METDEK 500 ROOFING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

PURLIN

ROOF FRAMING

STOPENDS TO ROOF CLADDING

PRE-FINISHED CHANGE OF ROOF PITCH FLASHING

BUILDING PAPER CONTINUOUS OVER FLASHING SHOWN DASHED

BUILDING PAPER CONTINUOUS UNDER FLASHING SHOWN DASHED

45.0

0°10

.00°

MIN. 250mm

CLEARANCE

MIN. 10mm

X

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

NOTCHED EDGE DRESSED OVER METDEK 500 RIBSMETALCRAFT METDEK 500 ROOFING

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

ROOF - CHANGE PITCH

05 / 242014

Page 7: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

METALCRAFT METDEK 500 ROOFING

PRE-FINISHED EAVE FLASHING

BUILDING PAPER SHOWN DASHED

METALLINE™ FASCIA

FASCIA BRACKET

SOFFIT LINING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

METALLINE™ QUAD GUTTER

METALLINE™ QUAD GUTTER OVERSTRAP

TIMBER ROOF FRAMING

15.00°

OVE

RLA

P

MIN

. 35m

m

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

SPRING CLIP

TIMBER PURLIN

EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

EAVE WITH METALLINE FASCIA

06 / 242014

Page 8: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

TIMBER FASCIA

METALLINE™ QUAD GUTTER

METALLINE™ QUAD GUTTER INTERNAL BRACKET

15.00°

SOFFIT LINING

TIMBER ROOF FRAMING

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

OVE

RLA

P

MIN

. 35m

mTIMBER PURLIN

PRE-FINISHED EAVE FLASHING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

STST OR GALV. FLAT HEAD NAIL OR FLASHING

PRE-FINISHED 8g WAFER-TEK SCREW

EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

EAVE WITH INTERNAL GUTTER BRACKET

07 / 242014

Page 9: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

TIMBER FASCIA

METALLINE™ QUAD GUTTER

METALLINE™ QUAD GUTTER INTERNAL BRACKET

15.00°

SOFFIT LINING

TIMBER ROOF FRAMING

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

OVE

RLA

P

MIN

. 35m

m

TIMBER PURLIN

PRE-FINISHED EAVE FLASHING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

SNOW STRAP AS REQUIRED

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

PRE-FINISHED 8g WAFER-TEK SCREW

EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

EAVE WITH SNOW STRAP

08 / 242014

Page 10: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

TIMBER PACKER

FASCIA BOARD TIMBER PACKER

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

15.00°

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

OVE

RLA

P

MIN

. 35m

mTIMBER PURLIN

PRE-FINISHED EAVE FLASHING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

QUARTER ROUND GUTTER

QUARTER ROUND GUTTER INTERNAL BRACKET

PRE-FINISHED 8g WAFER-TEK SCREW

EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

FLUSH EAVE WITH INTERNAL GUTTER BRACKET

09 / 242014

Page 11: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

TIMBER PURLIN

PRE-FINISHED EAVE FLASHING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

15.00°

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

TIMBER PACKER

FASCIA BOARD TIMBER PACKER

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

OVE

RLA

P

MIN

. 35m

m

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

QUARTER ROUND GUTTER

QUARTER ROUND GUTTER EXTERNAL BRACKET

PRE-FINISHED 8g WAFER-TEK SCREW

EAVE FLASHING REQUIRED WHEN ALL OF THE FOLLOWING CONDITIONS ARE MET- ROOF PITCH 10°, OR- SOFFIT WIDTH 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

FLUSH EAVE WITH EXTERNAL GUTTER BRACKET

10 / 242014

Page 12: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

TIMBER PACKER

BARGE BOARD

PRE-FINISHED BARGE FLASHING

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

PURLIN

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE

ROOF FRAMING

TIMBER PACKER

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGEHEMMED EDGE

ZPRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

Y

5mm

GAP

PRE-FINISHED SELF DRILLING/TAPPING SCREW WITH RUBBER WASHER

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METDEK 500)

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METDEK 500)

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet 1 : 2

BARGE WITH PROFILED CLADDING

11 / 242014

Page 13: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

PRE-FINISHED BARGE FLASHING

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

FLY RAFTER

BARGE BOARD

BUILDING PAPER SHOWN DASHED

PURLIN

SOFFIT LINING

PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE

Z

PRE-FINISHED SELF DRILLING/TAPPING SCREW WITH RUBBER WASHER

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

HEMMED EDGE

Y

5mm

GAP

METALCRAFT METDEK 500 ROOFING

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METDEK 500)

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METDEK 500)

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet 1 : 2

BARGE OVERHANG

12 / 242014

Page 14: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

15.0

MIN

. 5.0

GN

L

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

TIMBER PACKER

BARGE BOARD

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

PRE-FINISHED PARAPET CAP FLASHING

TIMBER PACKER

BUILDING PAPER TO PROVIDE SEPARATION OF METAL CAPPING AND TIMBER SHOWN DASHED

TIMBER PURLIN

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

WALL FRAMING ROOF FRAMING

PRE-FINISHED APRON FLASHING

TIMBER NOG FOR FIXING APRON FLASHING

CONTINUOUS TIMBER PACKING

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

PRE-FINISHED SELF DRILLING / TAPPING SCREW WITH RUBBER WASHER

PRE-FINISHED 8g WAFER-TEK SCREW BEDDED IN SILICONE

Z

NOTCHED EDGE DRESSED OVER METDEK 500 RIBS

STOPENDS TO ROOF CLADDING

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

MIN. 70mm

G

N

L

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm

MIN. 90mmPLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

G

N

L

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

PARAPET WITH TRANSVERSE APRON

13 / 242014

Page 15: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

* METDEK 500 MIN. ROOF PITCH = 3°

15.0

GN

L

STOPENDS ROOF CLADDING

ROOF FRAMING

WALL FRAMING

PVC CAVITY CLOSER

WEATHERBOARDS ON CAVITY

CANT STRIP PACKER

NOG FOR FIXING APRON FLASHING

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

METALCRAFT METDEK 500 ROOFING

BUILDING PAPER SHOWN DASHED

PRE-FINISHED APRON FLASHING

BUILDING PAPER OVER FLASHING SHOWN DASHED

BUILDING PAPER SHOWN DASHED

PURLIN

NOTCHED EDGE DRESSED OVER METDEK 500 RIBS

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm (EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE OR TURN-DOWN TO ROOFING)

G

N

L

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

G

N

L

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

TRANSVERSE APRON

14 / 242014

Page 16: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

PURLIN

GN

PRE-FINISHED APRON FLASHING

WEATHERBOARDS ON CAVITY

CANT STRIP PACKER

BUILDING PAPER OVER FLASHING SHOWN DASHED

STST OR GALV. FLAT HEAD NAIL FOR FIXING

NOG FOR FIXING APRON FLASHING

PVC CAVITY CLOSER

METALCRAFT METDEK 500 ROOFING

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

M

WALL FRAMING

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

5mm

GAP

PRE-FINISHED SELF DRILLING/TAPPING SCREW WITH RUBBER WASHER

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH 10°

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

G

N

M

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METDEK 500)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METDEK 500)

G

N

M

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet 1 : 2

PARALLEL APRON

15 / 242014

Page 17: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.3° and MAX. 45°- PIPE DIAMETER MAX. 85mm 15.00°

* MIN. 10° FOR PIPE PENETRATION

METALCRAFT METDEK 500 ROOFING

EPDM FLEXIBLE CONE SLEEVE MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012.

BUILDING PAPER SHOWN DASHED

METALCRAFT METDEK 500 ROOFING

PIPE (PIPE DIAMETER MIX. 85mm)

EPDM FLEXIBLE CONE SLEEVE

BUILDING PAPER SHOWN DASHED

MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012.

TIMBER PURLIN

ROOF FRAMINGMETALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

TIMBER PURLIN

ROOF FRAMING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 5

MAX. 85mm DIAMETER PIPE PENETRATION

16 / 242014

Page 18: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.3°- PIPE DIAMETER OVER 85mm AND MAX. 500mm- PIPE TO BE POSITIONED AS CLOSE TO ROOF RIDGE AS POSSIBLE

L

PRE-FINISHED SOAKER FLASHING UNDER PRE-FINISHED ROOF RIDGE CAP FLASHING

PIPE (PIPE DIAMETER OVER 85mm AND MAX. 500mm)

EPDM FLEXIBLE CONE SLEEVE

METALCRAFT METDEK 500 ROOFING

MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012. PRE-FINISHED SOAKER FLASHING WITH

PRE-FINISHED POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

METALCRAFT METDEK 500 ROOFING

PURLINROOF FRAMING

PRE-FINISHED ROOF RIDGE CAP FLASHING

METALCRAFT METDEK 500 CLIP SYSTEM WITH SPIRAL SHANK NAILS

EPDM FLEXIBLE CONE SLEEVE

NOGS BETWEEN PURLINS FOR PENETRATION

5mm

GAP

5mm

GAP

PURLIN

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

X

M

15.00°

* MIN. 10° FOR PIPE PENETRATION

REFER TO SHEET NO. 14/24 TRANSVERSE APRON

REFER TO SHEET NO. 16/24 PARALLEL APRON

REFER TO SHEET NO. 01/24 ROOF RIDGE

L

M

X

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 AND MRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 5

OVER 85mm DIAMETER PIPE PENETRATION

17 / 242014

Page 19: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

PRE-FINISHED RIDGE CAP FLASHING

METALCRAFT METDEK 500 ROOFING

PRE-FINISHED BARGE FLASHING

PURLIN

ROOF FRAMING

FASCIA BOARD

WALL CLADDING ON CAVITY

WALL FRAMING

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D RIDGE TO BARGE JUCTION

18 / 242014

Page 20: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

PRE-FINISHED RIDGE FLASHING

METALCRAFT METDEK 500 ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FOR MINIMUM ROOF OVERHANG

PRE-FINISHED BARGE FLASHING

PRE-FINISHED APRON FLASHING

PRE-FINISHED HIP FLASHING

GUTTER

FASCIA BOARD

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

WALL CLADDING ON CAVITY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D DUTCH GABLE

19 / 242014

Page 21: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

GUTTER

METALCRAFT METDEK 500 ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FOR MINIMUM ROOF OVERHANG

WALL CLADDING ON CAVITY

PRE-FINISHED APRON FLASHING WITH HEMMED EDGE

PRE-FINISHED APRON DIVERTER

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

WALL CLADDING ON CAVITY

FASCIA BOARD

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D APRON

20 / 242014

Page 22: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

PRE-FINISHED SOAKER FLASHING

EPDM FLEXIBLE CONE SLEEVE

MALLEABLE FLANGE, SCREW OR RIVET FIXED, AND SEALED TO ROOFING PROFILE. FIT NEOPRENE WASHERS TO ALL SCREW FIXINGS. FITTED ON 45° ANGLE IN PLAN. REFER TO MRM CODE OF PRACTICE VERSION 2 2/2012.

PRE-FINISHED ROOF RIDGE FLASHING

PIPE (DIAMETER OVER 85mm DIAMETER)

METALCRAFT METDEK 500 ROOFING

PRE-FINISHED ROOF BARGE FLASHING

PRE-FINISHED SOAKER FLASHING LINE UNDER PRE-FINISHED ROOF RIDGE FLASHING

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D OVER 85mm DIAMETER PIPE PENETRATION

21 / 242014

Page 23: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

METALCRAFT METDEK 500 ROOFING TURN DOWN INTO GUTTER

PRE-FINISHED APRON FLASHING

WALL CLADDING ON CAVITY

PREFINISHED VALLEY GUTTER

PURLIN

PRE-FINISHED SOAKER FLASHING

VALLEY BOARD

ROOF FRAMING

MIN

. 110

mm

UPS

TAN

D

MIN. 110mm UPSTAND PRE-FINISHED 1.6mm ALUMINIUM WELDED SOAKER FLASHING

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

DIVERTER FLASHING ON UPPER SIDE OF CHIMNEY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D CHIMNEY PENETRATION

22 / 242014

Page 24: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D RIDGE/BARGE FLASHINGS

23 / 242014

OPTION 1

RIDGE CAP FLASHING

ADDITIONAL SADDLE FLASHING

BARGE FLASHING

RIDGE CAP FLASHING

ADDITIONAL SADDLE FLASHING

BARGE FLASHING

OPTION 2

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Page 25: C:UsersFrancesDesktopRRMD500 Residential Roof Metdek 5002017

(3) PRE-FINISHED 3D SADDLE FLASHING

(2) PRE-FINISHED APRON FLASHING

(1) PRE-FINISHED HIP FLASHING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code of practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is the responsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as a single line for simplicity and is indicative only. Building paper type and method of installation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetdek 500

RRMD500 ScaleDate Sheet

3D DUTCH GABLE FLASHINGS

24 / 242014

* PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.