DN
DN
UP
DN
DN
LOUNGE
165
CLASSROOM
162
CLASSROOM
161
CLASSROOM
160
CLASSROOM
158
CLASSROOM
156
CLASSROOM
154
CLASSROOM
153
CLASSROOM
152
CSCT
155
SENSORY
150
LIBRARY
148
WORK ROOM
149
BR
EA
K O
UT
157
NURSE
103
PR
INC
IPA
L
105
RECEPTION
102WORK ROOM
104
VE
ST
IBU
LE
100
COUNS.
108
SPEECH
110
CONFERENCE
111
CLASSROOM
113
CLASSROOM
114
CLASSROOM
115
CLASSROOM
116
CLASSROOM
117
CLASSROOM
118
CLASSROOM
119
JAN
122
CLASSROOM
125
FR
C
126
ST
OR
AG
E
127
ART
131
OFFICE
134
ART
136
MUSIC
140
GYM
132
STORAGE
138
KITCHEN
143
DINING
142
IB COORDINATOR
172
STORAGE
173
COMPUTER LAB
171
LEARNING
STREET
170
FIRE
109
VESTIBULE-ELEV
175
HALL
112
T002
T003
T002 T003
HALL
163
HALL
151
HALL
147
HALL
141
MECH
011
ELEC.
012
MECH
013
MECH
014MECH
015
STOR.
177
HALL
112
HALL
112
IT
120
IT
128
1 2
3 4 E.A
5
6
A
E.12
E.5
C
E
X.B
D
B
X.A
2"x6" CABLE TRAY
MUSIC
205CLASSROOM
206
CLASSROOM
207
CLASSROOM
208
CLASSROOM
209
CLASSROOM
210
CLASSROOM
211
CLASSROOM
212
CLASSROOM
218
CLASSROOM
219
BOYS
216
GIRLS
214
JAN
215VESTIBULE_ELEV
220
_______________
T004
1
ROOF BELOW
1 2
3
X.B
D
B
X.A
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
REVISIONS
2300 R
EG
EN
T S
T., S
TE
207
MIS
SO
ULA
, M
T 5
9801
PH
. 406.3
27.0
629
FA
X. 406.5
41.9
881
TELECOMM PLANS -FIBER OPTICBACKBONE
T001
LE
WIS
& C
LA
RK
AD
DIT
ION
& R
EN
OV
AT
ION
PR
OJE
CT
DE
SC
RIP
TIO
N L
INE
2
© 2018 | ALL RIGHTS RESERVED
MIS
SO
ULA
CO
UN
TY
SC
HO
OL D
IST
RIC
T
01.22.2019
CHECKED BY | PW
DRAWN BY | JG
CABLING SET
1/16" = 1'-0"1
TELECOMM PLAN - 1ST FLOOR -OVERALL BACKBONE CABLING
1/16" = 1'-0"2
TELECOMM PLAN - 2ND FLOOR -OVERALL
NORTH REF
NORTH REF
DN
129-1
106-3
108-1
107-1
111-1
132-2
175-2
175-1
128-1
131-1
112-7
118-2
119-1
122-1
125-1
126-1
127-1
114-1
113-1
124-2
121-2
106-2
115-1
116-1
117-1
112-1
135-1132-1
131-5
152-1
152-1
112-3
112-2
112-4
112-5
124-3
121-1
118-3
118-5
117-3
117-2
119-3
119-2 119-5
117-5
116-3 115-3 113-3
125-3
116-2 115-2 114-2 113-4
116-5
115-5
125-5
114-3
125-2
113-5
118-1
118-4 119-4 125-4
117-4 116-4 115-4114-4
113-6
157-1
106-1
135-1132-1
113-2
D171-3
110-1
109-1
108-2
175-2
T002
T003
T00
2
T00
3
COUNS.
108
SPEECH
110
CONFERENCE
111
CLASSROOM
113
CLASSROOM
114
CLASSROOM
115
CLASSROOM
116
CLASSROOM
117
CLASSROOM
118
CLASSROOM
119
GIRLS
121
BOYS
124
JAN
122
CLASSROOM
125
FRC
126
ST
OR
AG
E
127
STORAGE
130
OT
129
FIRE
109
VESTIBULE-ELEV
175WAITING
106HALL
112
(E) 22
(E)(E) 2
22222
2 22
2
2
(E)
PR
INC
IPA
L
105
HALL
151HALL
152
CONFERENCE
107
HALL
112
HALL
112
IT
128
2
2
2
2
22
22
2
2
2
2
2
2
2
2
2
2
1
2
3
E.5
C
E
X.B X.B
D
B
B
X.A
3
4
3
4
5
(1)-2" EMT CONDUIT SLEEVE BETWEEN CONFERENCE 107 AND PRINCIPAL 105. LOCATED @ ±10'-0" A.F.F., BY ELECTRICAL.(2)-4" EMT CONDUITS BETWEEN IT 128 AND HALL 112.
46
66
6
6
6
6
(1)-4" EMT CONDUIT BETWEEN CABLE TRAYS IN FIRST FLOOR HALL 112 AND SECOND FLOOR HALL 204, BY ELECTRICAL.
2 (E)
2
(E)
2 (E)
2"x6" CABLE TRAY,BY ELECTRICAL.
6LB 2 LB 2
CA
M
CA
M
CAM
7
7
7
8
8
8
8
8 8 8
88
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE. (E) INDICATES EXISTING.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX w/ A SINGELE GANG MUD RING AND A 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY SLEEVE OR EMT CONDUIT, BY CABLING CONTRACTOR. SEE PLANS FOR ADD'L INFO.
INDICATES CABLE PATHWAY.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F. BY CABLING CONTRACTOR.
(E)INDICATES EXISTING WALL MOUNTED WORK AREA OUTLET.
(E)
INDICATES EXISTING CEILING MOUNTED WORK AREA OUTLET.
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
3. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
4. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
5. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
6. PENETRATION INTO ROOM BY CABLING CONTRACTOR.
7. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLEINSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.
8. ALL CABLING IN NOTED ROOMS SHALL BE SURFACE MOUNTED. SEE SPECIFICATION 27 12 00 FOR ADD'L INFO. PROVIDED BY CABLING CONTRACTOR.
E010-1
E013-1
E014-1
E010-2
E015-1
E010-3
E.5
X.A
TC4
FOR TEMPERATURE CONTROL PANEL.COORDINATE LOCATION w/ MECHANICAL CONTRACTOR.
BOILER
010
MECH
011
ELEC.
012
MECH
013
MECH
014
MECH
015
2
(1)-1" EMT CONDUIT BETWEEN CEILING SPACE IN BOILER 010 AND CEILING SPACE IN ART 131, BY ELECTRICAL.
2
FOR FIRE ALARM CONTROL PANEL.COORDINATE LOCATION w/ FIRE ALARM CONTRACTOR.
REVISIONS
2300 R
EG
EN
T S
T., S
TE
207
MIS
SO
ULA
, M
T 5
9801
PH
. 406.3
27.0
629
FA
X. 406.5
41.9
881
TELECOMM PLAN - 1STFLOOR - SOUTH WING& BOILER
T002
LE
WIS
& C
LA
RK
AD
DIT
ION
& R
EN
OV
AT
ION
PR
OJE
CT
DE
SC
RIP
TIO
N L
INE
2
© 2018 | ALL RIGHTS RESERVED
MIS
SO
ULA
CO
UN
TY
SC
HO
OL D
IST
RIC
T
01.22.2019
CHECKED BY | PW
DRAWN BY | JG
CABLING SET
1/8" = 1'-0"1
TELECOMM PLAN - 1ST FLOOR - SOUTHWING NORTH REF
1/8" = 1'-0"2
TELECOMM PLAN - BOILER ROOM NORTH REF
160-1
173-1
172-1
105-2
155-1
153-4
148-1
148-2
107-1160-3
104-1
162-1
162-3
161-1
159-1158-1
156-1
154-1
153-1
152-1
147-1
144-1
150-1
101-1
142-1
171-1
141-1
106-1
161-2
105-1
143-2
103-1
142-1
143-1
166-2
168-2
101-3
164-5
100-2
154-2
145-1
106-2
169-1
167-1
135-1
164-1
149-1
149-1
132-1
132-3
153-2
135-1132-1
170-1
109-1
141-10
141-11
120-1
LOUNGE
165
CLASSROOM
162
CLASSROOM
161
CLASSROOM
160
CLASSROOM
158
CLASSROOM
156
CLASSROOM
154
CLASSROOM
153
CLASSROOM
152
CSCT
155
SENSORY
150
LIBRARY
148
WO
RK
RO
OM
149
BOYS
145
GIRLS
146
BR
EA
K O
UT
157
NURSE
103
PR
INC
IPA
L
105
RE
CE
PT
ION
102
WORK ROOM
104
VESTIBULE
100
ART
131
OFFICE
134
ART
136
MUSIC
140
GYM
132
STORAGE
138
KITCHEN
143
DINING
142
IB C
OO
RD
INA
TO
R
172
STORAGE
173
COMPUTER LAB
171
LEARNING
STREET
170
FOYER
101
HALL
164
T002 T003
T002
T003
2
(E)
(E)
2
(E) 2
(E) 2
2
(E) (E)
2
(E) 2
2
(E)
(E) 2
2
(E)
(E) 2
(E) 2
2
(E)
2 (E)
(E)
2 (E)
2
(E)
(E)
2 (E)
2 (E)
2
(E)
2
(E)
(E)(E)
2
(E)
2
(E)
2 (E)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
2
2
2
2
2
2
2
2
22
2
2
2
2
1
1
1
2
2
BOYS
137
GIRLS
139
HALL
163
HALL
151
HALL
147
HALL
141
VESTIBULE_GYM
135
IT
120IT
128
LOUNGE
165
2
2
1
1
1
1
1
1
2
2
2
2
2
2
2
2 2 2
12
1
1
1
12
2
3
4
E.A
5 6
A
E.12
E.5
E.5
C C
E
X.A
LB
STOR.
177
3
4
3
4
5
(1)-2" EMT CONDUIT SLEEVE BETWEEN CONFERENCE 107 AND PRINCIPAL 105. LOCATED @ ±10'-0" A.F.F, BY ELECTRICAL.
(2)-4" EMT CONDUITS BETWEEN IT 128 AND HALL 112. STUBBED 3" INTO CEILING SPACE IN IT 128 AND STUBBED TO CABLE TRAY IN HALL 112.
4
3
3
3
3
3 3
3
3
3
3
33
4
3
3
3
5
(2) EXISTING 4" FIRE RATED STI READY SLEEVES BETWEEN CEILING SPACE IN IT 120 AND HALL 163.
2
2
2
1
2
1
2
1
2
AC
1
2
AC
1
2
AC
1
2
1
AC21
2
5
2
2
2
(1)-1" EMT CONDUIT BETWEEN CEILING SPACE IN BOILER 010 AND CEILING SPACE IN ART 131, BY ELECTRICAL.2
2
2
4
3
LB
LB
LB
7
CAM
CA
M
CA
M
CA
M
CAM
2
2 (E)
7
7
7
7
8
8
EXISTING RACK LOCATION.RELOCATE FIBER OPTIC CABLE AND PATCH PANEL TO IT 120. NOTIFY DISTRICT 48 HOURS PRIOR TO RELOCATION.
PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE
PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSUREPROVIDE AND
INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE
PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE
2
2
2
2
(E) 2
2 (E)
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
3. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
4. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
5. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
6. PENETRATION INTO ROOM BY CABLING CONTRACTOR.
7. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLEINSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.
8. ALL CABLING IN NOTED ROOMS SHALL BE SURFACE MOUNTED. SEE SPECIFICATION 27 12 00 FOR ADD'L INFO. PROVIDED BY CABLING CONTRACTOR.
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE. (E) INDICATES EXISTING.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX w/ A SINGELE GANG MUD RING AND A 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY SLEEVE OR EMT CONDUIT, BY CABLING CONTRACTOR. SEE PLANS FOR ADD'L INFO.
INDICATES CABLE PATHWAY.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F. BY CABLING CONTRACTOR.
(E)INDICATES EXISTING WALL MOUNTED WORK AREA OUTLET.
(E)
INDICATES EXISTING CEILING MOUNTED WORK AREA OUTLET.
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
REVISIONS
2300 R
EG
EN
T S
T., S
TE
207
MIS
SO
ULA
, M
T 5
9801
PH
. 406.3
27.0
629
FA
X. 406.5
41.9
881
TELECOMM PLAN - 1STFLOOR - NORTH WING
T003
LE
WIS
& C
LA
RK
AD
DIT
ION
& R
EN
OV
AT
ION
PR
OJE
CT
DE
SC
RIP
TIO
N L
INE
2
© 2018 | ALL RIGHTS RESERVED
MIS
SO
ULA
CO
UN
TY
SC
HO
OL D
IST
RIC
T
01.22.2019
CHECKED BY | PW
DRAWN BY | JG
CABLING SET
1/8" = 1'-0"2
TELECOMM PLAN - 1ST FLOOR - NORTHWING NORTH REF
217-1
220-1
205-1
204-2
204-2
204-1
204-1
205-5
212-1
212-3
212-2
212-4
211-2
215-1
218-1
207-1
206-1
208-1
209-1
210-1
214-1
211-3
211-5
210-3
210-2
212-5
210-5
209-3 208-3 206-3
218-3
209-2 208-2 206-2
209-5
208-5
218-5
207-5
218-2
206-5
211-1
211-4 218-4
210-4 209-4 208-4 206-4
205-6
219-1
205-4
205-3
205-2
207-3
207-2
207-4
216-2
214-2
216-1
MUSIC
205CLASSROOM
206
CLASSROOM
207
CLASSROOM
208
CLASSROOM
209CLASSROOM
210
CLASSROOM
211
CLASSROOM
212
CLASSROOM
218
CLASSROOM
219
JAN
215VESTIBULE_ELEV
220
2
2
AC
2
2
222
2
AC
2
222
2 2 2
2
2
222
2
2
2
1
PROVIDE VIKING E-1600-30A EMERGENCY PHONE.PROVIDE 4" SQUARE BOX w/ 3/4" CONDUITSTUBBED TO ACCESSIBLE CEILING SPACE.
1
2
3
3
E.5
C
E
X.B
D
B
X.A
BOYS
216
GIRLS
214
TOILET
217
HALL
204
HALL
204 HALL
204
(1)-4" EMT CONDUIT BETWEEN CABLE TRAYS IN FIRST FLOOR HALL 112 AND SECOND FLOOR HALL 204, BY ELECTRICAL.
(1)-2" EMT CONDUIT BETWEEN CEILING SPACES IN CLASSROOM 206 AND HALL 204.
6
6
6
6
6
6
36
4
6
2
FOR ELEVATOR CONTROL PANEL.COORDINATE LOCATION w/ ELECTRICALAND ELEVATOR CONTRACTOR.
1
2"x6" CABLE TRAY,BY ELECTRICAL.
2
2
8
8
8
8 8
8
8
8
8
8
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE. (E) INDICATES EXISTING.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX w/ A SINGELE GANG MUD RING AND A 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY SLEEVE OR EMT CONDUIT, BY CABLING CONTRACTOR. SEE PLANS FOR ADD'L INFO.
INDICATES CABLE PATHWAY.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F. BY CABLING CONTRACTOR.
(E)INDICATES EXISTING WALL MOUNTED WORK AREA OUTLET.
(E)
INDICATES EXISTING CEILING MOUNTED WORK AREA OUTLET.
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. SURFACE RACEWAY AND OUTLET BOX BY BY CABLING CONTRACTOR.
3. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
4. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
5. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
6. PENETRATION INTO ROOM BY CABLING CONTRACTOR.
7. NOT USED
8. ALL CABLING IN NOTED ROOMS SHALL BE SURFACE MOUNTED. SEE SPECIFICATION 27 12 00 FOR ADD'L INFO. PROVIDED BY CABLING CONTRACTOR.
REVISIONS
2300 R
EG
EN
T S
T., S
TE
207
MIS
SO
ULA
, M
T 5
9801
PH
. 406.3
27.0
629
FA
X. 406.5
41.9
881
TELECOMM PLAN - 2NDFLOOR - SOUTH WING
T004
LE
WIS
& C
LA
RK
AD
DIT
ION
& R
EN
OV
AT
ION
PR
OJE
CT
DE
SC
RIP
TIO
N L
INE
2
© 2018 | ALL RIGHTS RESERVED
MIS
SO
ULA
CO
UN
TY
SC
HO
OL D
IST
RIC
T
01.22.2019
CHECKED BY | PW
DRAWN BY | JG
CABLING SET
1/8" = 1'-0"1
TELECOMM PLAN - 2ND FLOOR - SOUTHWING NORTH REF
RELOCATED CORNING 2U FIBER OPTIC PATCH PANELPART #CCH-02U
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
EXISTING COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
EXISTING CHATSWORTH UNIVERSAL CABLE RUNWAY (1 1/2"H x 12"W)
EXISTING CHATSWORTH GLOBAL STANDARD PACK,PART #57004-703, TYP.
(2) EXISTING 4" FIRE RATED STI READY SLEEVES BETWEEN CEILING SPACE IN IT120 AND HALL 163
APC, SMT1500RM2UNCUNINTERRUPTABLE POWER SUPPLY
E.5
EXISTING CHATSWORTH GLOBAL STANDARD PACK, PART #57004-703, TYP.
EXISTING CHATSWORTH UNIVERSAL CABLE RUNWAY ( 1 1/2"H x 12"W)
IT
120
(2) EXISTING 4" FIRE RATED STI READY SLEEVES BETWEEN CEILING SPACE IN IT120 AND HALL 163
CORNING 2U FIBER OPTIC PATCH PANELPART #CCH-02U
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
CHATSWORTH UNIVERSAL CABLE RUNWAY (1 1/2"H x 12"W)
CHATSWORTH GLOBAL STANDARD PACK,PART #57004-703, TYP.
(2)-4" EMT CONDUITS BETWEEN IT 128 AND HALL 112, BY ELECTRICAL.
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL FINGER DUCT PANELPART #1357163-1
COMMSCOPE 48-PORT CATEGORY 6 PATCH PANELPART CCP-UDDM-SL-2U-48 w/ (2) USL600-BLK-24 INSERTS
ETHERNET SWITCH, BY OWNER
APC, SMT2200RM2UNCUNINTERRUPTABLE POWER SUPPLY
IT
128
E.5
CHATSWORTH UNIVERSAL CABLE RUNWAY ( 1 1/2"H x 12"W)
CHATSWORTH GLOBAL STANDARD PACK,PART #57004-703, TYP.
(2)-4" EMT CONDUITS BETWEEN IT 128 AND HALL 112, BY ELECTRICAL.
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. IT RACKS, COMPONENTS, AND LADDER RACK BY OWNER.
PLAN NOTES:
REVISIONS
2300 R
EG
EN
T S
T., S
TE
207
MIS
SO
ULA
, M
T 5
9801
PH
. 406.3
27.0
629
FA
X. 406.5
41.9
881
TELECOMMELEVATION - IT 120 &128
T300
LE
WIS
& C
LA
RK
AD
DIT
ION
& R
EN
OV
AT
ION
PR
OJE
CT
DE
SC
RIP
TIO
N L
INE
2
© 2018 | ALL RIGHTS RESERVED
MIS
SO
ULA
CO
UN
TY
SC
HO
OL D
IST
RIC
T
01.22.2019
CHECKED BY | PW
DRAWN BY | JG
CABLING SET
1IT 120
3/4" = 1'-0"2
TELECOMM PLAN - IT 120
3IT 128
3/4" = 1'-0"4
TELECOMM PLAN - IT 128 NORTH REF NORTH REF
SheetsT001 - TELECOMM PLANS - FIBER OPTIC BACKBONET002 - TELECOMM PLAN - 1ST FLOOR - SOUTH WING & BOILERT003 - TELECOMM PLAN - 1ST FLOOR - NORTH WINGT004 - TELECOMM PLAN - 2ND FLOOR - SOUTH WINGT300 - TELECOMM ELEVATION - IT 120 & 128