www.nordencommunication.com Copper System D10 EXTERNAL TELEPHONE CABLE CABLE CONSTRUCTION Insulation HD PE (Polyethylene) Sheath Nylon PA-12 Sheath Colour Transparent Insulation Colour Black PHYSICAL CHARACTERISTICS Characteristic Value Wire Diameter 0.28 mm Nom. Conductor Diameter 0.84 mm Nom. Overall Insulation Diameter 1.8 mm Nom. Overall Sheath Diameter 2.15 mm Nom. Overall Cable Diameter 4.30 mm CABLE STANDARD DEF STAN 61-12 Part 12 MIL-C-13294 SWA Conductor Insulation Sheath Annealed Tinned Copper Conductor D10 External Telephone Cable from NORDEN are designed for field Communication in all types of terrain and climatic environments. This single pair cable has light weight which helps for easy insulation and maintenance. Conductor 7 Strands Consisting of 4 Annealed Tinned Copper Wire and 3 HT Galvanized Steel wire stranded together. Breaking Load 500 N Operating Temperature o o -40 C to +80 C Voltage Rateing 1 KVA, AC Cable Weight 14 Kg/Km Twisting Twisted pair with a lay of Max. 250 mm

D10 External Telephone Cable - Norden Communicationnordencommunication.com/.../8293-D10_External_Telephone_Cable.pdf · DEF STAN 61-12 Part 12 MIL-C-13294 SWA Conductor Insulation

Embed Size (px)

Citation preview

Page 1: D10 External Telephone Cable - Norden Communicationnordencommunication.com/.../8293-D10_External_Telephone_Cable.pdf · DEF STAN 61-12 Part 12 MIL-C-13294 SWA Conductor Insulation

www.nordencommunication.com

Copp

er

Sys

tem

D10 EXTERNAL TELEPHONE CABLE

CABLE CONSTRUCTION

Class 1 Solid annealed Bare Copper Conductors to BS 6360

Insulation HD PE (Polyethylene)

Sheath Nylon PA-12

Sheath Colour Transparent

Insulation Colour Black

PHYSICAL CHARACTERISTICS

Characteristic Value

Wire Diameter 0.28 mm

Nom. Conductor Diameter 0.84 mm

Nom. Overall Insulation Diameter 1.8 mm

Nom. Overall Sheath Diameter 2.15 mm

Nom. Overall Cable Diameter 4.30 mm

CABLE STANDARD

DEF STAN 61-12 Part 12

MIL-C-13294

SWA Conductor

Insulation

Sheath

Annealed Tinned Copper Conductor

D10 External Telephone Cable from NORDEN are designed for fieldCommunication in all types of terrain and climatic environments.This single pair cable has light weight which helps for easy insulation and maintenance.

Conductor7 Strands Consisting of 4 Annealed Tinned Copper Wire and 3 HT Galvanized Steel wire stranded together.

Breaking Load 500 N

Operating Temperatureo o-40 C to +80 C

Voltage Rateing 1 KVA, AC

Cable Weight 14 Kg/Km

Twisting Twisted pair with a lay of Max. 250 mm

Page 2: D10 External Telephone Cable - Norden Communicationnordencommunication.com/.../8293-D10_External_Telephone_Cable.pdf · DEF STAN 61-12 Part 12 MIL-C-13294 SWA Conductor Insulation

www.nordencommunication.com

Copper

Sys

tem

ORDERING INFORMATION

Part Number Description No. of Pair

212-22157001X D10 External Telephone Cable 1 Pair

PACKING INFORMATION

Cable Length(meter)

Packing Mode N.W(kg)

G.W(kg)

500 Plastic Spool (DIN 355) 7.00 9.00

D10 EXTERNAL TELEPHONE CABLE

ELECTRICAL CHARACTERISTICS

Characteristic Unit Value

Max. DC Loop Resistance Ω/km 151

Insulation Resistance at Room Temperature MΩ/km 3500

Min. Dielectric strength Kv 3

Attenuation @ 400 Hz dB/Km 1.2

Attenuation @ 3300 Hz dB/Km 2.3

Part Number