DESCRIPTION
This booklet is prepared in accordance with SOLAS II-1 Reg. 19 requirements and IMO MSC/Circ.1245 (Guidelines for Damage Control Plans and Information to the Master) and intends to provide the ship's officers with clear information on the ship's watertight compartmentation and equipment related to maintaining the effectiveness of ship’s boundaries Applicability: passenger ships, regardless of size, since 1974 dry cargo ships over 100m in length, constructed on or after 1 February 1992 dry cargo ships over 80m in length, constructed on or after 1 July 1998 all ships, regardless size, constructed on or after 1 January 2009 Approval requirements: Approval by the Administration is mandatory
Citation preview
M/V “VSLNAME” IMO No: 9999999
DAMAGE CONTROL
BOOKLET
ALPHA MARINE CONSULTING LTD. MARINE CONSULTANTS & SURVEYORS T: +30 210 4518717 (5 LINES), F: +30 210 4283253
[email protected] | www.alphamrn.com
SAMPLE
No. Revision Date
TOTAL THIRTY (30) SHEETS WITH COVER
VESSEL: M/V “VSLNAME” IMO NO.: 9999999
TITLE: DAMAGE CONTROL BOOKLET
DWG. NO.: xxxx-DCB
REVISION NO.: 1
ALPHA MARINE CONSULTING LTD.MARINE CONSULTANTS & SURVEYORS T: +30 210 4518717 (5 LINES), F: +30 210 4283253
[email protected] | www.alphamrn.com DATE: DD/MM/YY
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 3 OF 32
ALPHA MARINE CONSULTING LTD.
TABLE OF CONTENTS
PAGE 1. SCOPE..................................................................................................................... 4 2. GENERAL PARTICULARS ..................................................................................... 5 2.1. GENERAL ................................................................................................................ 5 2.2. PRINCIPAL DIMENSIONS....................................................................................... 5 2.3. FRAME SPACING.................................................................................................... 5 3. GENERAL INSTRUCTIONS.................................................................................... 6 4. DAMAGE CONTROL PLAN INFORMATION ......................................................... 7 4.1. GENERAL ................................................................................................................ 7 4.2. INTERNAL WATERTIGHT CLOSING APPLIANCES .............................................. 9 4.3. EXTERNAL WATERTIGHT CLOSING APPLIANCES........................................... 11 4.4. WEATHERTIGHT CLOSING APPLIANCES.......................................................... 12 4.5. NON-WATERTIGHT OPENINGS .......................................................................... 16 4.6. NON-WEATHERTIGHT OPENINGS ..................................................................... 16 5. ADDITIONAL INFORMATION............................................................................... 17 5.1. SOUNDING DEVICES, TANK VENTS & OVERFLOWS ....................................... 17 5.2. BILGE & BALLAST PUMPS................................................................................... 17 5.3. INSTRUCTIONS FOR OPERATING CROSS-FLOODING SYSTEMS.................. 18 5.4. MEANS OF ACCESSING AND ESCAPING FROM WATERTIGHT
COMPARTMENTS BELOW BHD DECK (UPPER DECK) .................................... 18 5.5. SOUNDING PIPES ................................................................................................ 21 5.6. TANK VENTS & OVERFLOWS WHICH DO NOT EXTEND ABOVE THE
WEATHER DECK .................................................................................................. 21 5.7. DE-WATERING SYSTEM FOR FORE SPACES................................................... 21 5.8. WATER INGRESS DETECTION SYSTEM............................................................ 22 5.9. DAMAGE STABILITY CALCULATIONS SUMMARY............................................. 23 5.10. CONTACT PROCEDURES AND DETAILS IN THE EVENT OF DAMAGE........... 26 APPENDIX 1. Damage Control & Watertight Integrity Plan 2. Bilge & Ballast Piping Diagram 3. Bilge & Ballast Piping Arrangement in Cargo Area 4. Venting & Sounding Piping Diagram
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 4 OF 32
ALPHA MARINE CONSULTING LTD.
1. SCOPE
This Booklet has been prepared in accordance with MSC / Circ. 919 (Guidelines for Damage Control Plans). It is intended to provide the ship's officers with clear information on the ship's watertight compartmentation and equipment related to maintaining the boundaries and effectiveness of the compartmentation so that, in the event of damage to the ship causing flooding, proper precautions can be taken to prevent progressive flooding through openings therein and effective action can be taken quickly to mitigate and, where possible, recover the ship's loss of stability.
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 5 OF 32
ALPHA MARINE CONSULTING LTD.
2. GENERAL PARTICULARS
2.1. GENERAL
Ship’s Name: VSLNAME Ship’s Type:
Flag:
Port of Registry:
Call Sign:
IMO Number: 9999999
Classification:
Built by:
Year Built:
Complement: 2.2. PRINCIPAL DIMENSIONS
Length O.A.:
Length B.P.:
Breadth (mld.):
Depth to Main Deck (mld.):
Summer Load Draught (extr.):
Freeboard Type: 2.3. FRAME SPACING
A.E. – Frame 16:
Frame 16 – 61:
Frame 61 – 107:
Frame 107 – A.E.:
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 6 OF 32
ALPHA MARINE CONSULTING LTD.
3. GENERAL INSTRUCTIONS
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 7 OF 32
ALPHA MARINE CONSULTING LTD.
4. DAMAGE CONTROL PLAN INFORMATION
4.1. GENERAL
COMPARTMENT BOUNDARIES
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 8 OF 32
ALPHA MARINE CONSULTING LTD.
COMPARTMENT BOUNDARIES
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 9 OF 32
ALPHA MARINE CONSULTING LTD.
4.2. INTERNAL WATERTIGHT CLOSING APPLIANCES
NO. LOCATION CLEAR
OPENING [mmxmm]
DESCRIPTION
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 10 OF 32
ALPHA MARINE CONSULTING LTD.
NO. LOCATION CLEAR
OPENING [mmxmm]
DESCRIPTION
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 11 OF 32
ALPHA MARINE CONSULTING LTD.
4.3. EXTERNAL WATERTIGHT CLOSING APPLIANCES
NO. QUAN. CLEAR
OPENING [mmxmm]
LOCATION DESCRIPTION / TYPE / MATERIAL
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 12 OF 32
ALPHA MARINE CONSULTING LTD.
4.4. WEATHERTIGHT CLOSING APPLIANCES a) Hatches
NO. QUAN. CLEAR
OPENING [mmxmm]
LOCATION DESCRIPTION / TYPE / MATERIAL
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 13 OF 32
ALPHA MARINE CONSULTING LTD.
b) Doorways
NO. QUAN. CLEAR
OPENING [mmxmm]
LOCATION DESCRIPTION / TYPE / MATERIAL
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 14 OF 32
ALPHA MARINE CONSULTING LTD.
c) Air Pipes
NO. QUAN.NOMINAL
DIAMETER [mm]
LOCATION DESCRIPTION / TYPE / MATERIAL
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 15 OF 32
ALPHA MARINE CONSULTING LTD.
d) Ventilation Openings
NO. QUAN.NOMINAL
DIAMETER [mm]
LOCATION DESCRIPTION / TYPE / MATERIAL
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 16 OF 32
ALPHA MARINE CONSULTING LTD.
4.5. NON-WATERTIGHT OPENINGS
NO. QUAN. CLEAR
OPENING [mmxmm]
LOCATION DESCRIPTION / TYPE / MATERIAL
4.6. NON-WEATHERTIGHT OPENINGS
NO. QUAN. CLEAR
OPENING [mmxmm]
LOCATION DESCRIPTION / TYPE / MATERIAL
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 17 OF 32
ALPHA MARINE CONSULTING LTD.
5. ADDITIONAL INFORMATION
5.1. SOUNDING DEVICES, TANK VENTS & OVERFLOWS
5.2. BILGE & BALLAST PUMPS
NO. LOCATION DESCRIPTION CAPACITY
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 18 OF 32
ALPHA MARINE CONSULTING LTD.
5.3. INSTRUCTIONS FOR OPERATING CROSS-FLOODING SYSTEMS 5.4. MEANS OF ACCESSING AND ESCAPING FROM WATERTIGHT
COMPARTMENTS BELOW BHD DECK (UPPER DECK) No.1 Void Tank (C):
NO. LOCATION DESCRIPTION
01
02
03, 04
05, 06
No.2 Void Tank (C):
NO. LOCATION DESCRIPTION
01
02
03, 04
05, 06
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 19 OF 32
ALPHA MARINE CONSULTING LTD.
No.3 Void Tank (C):
NO. LOCATION DESCRIPTION
01
02
03, 04
05, 06
No.4 Void Tank (C):
NO. LOCATION DESCRIPTION
01
02
03, 04
05, 06
No.5 Void Tank (C):
NO. LOCATION DESCRIPTION
01
02
03, 04
05, 06
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 20 OF 32
ALPHA MARINE CONSULTING LTD.
No.6 Void Tank (C):
NO. LOCATION DESCRIPTION
01
02
03, 04
05, 06
Engine Room:
NO. LOCATION DESCRIPTION
01
02
03
04
05
06
07
09
10
11
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 21 OF 32
ALPHA MARINE CONSULTING LTD.
5.5. SOUNDING PIPES
5.6. TANK VENTS & OVERFLOWS WHICH DO NOT EXTEND ABOVE THE WEATHER DECK
5.7. DE-WATERING SYSTEM FOR FORE SPACES
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 22 OF 32
ALPHA MARINE CONSULTING LTD.
5.8. WATER INGRESS DETECTION SYSTEM
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 23 OF 32
ALPHA MARINE CONSULTING LTD.
5.9. DAMAGE STABILITY CALCULATIONS SUMMARY
DAMAGE CASES:
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 25 OF 32
ALPHA MARINE CONSULTING LTD.
---------------------------------------------------------------------------- INITIAL CONDITION LLCON Dmid = m Trim = m Disp = MT Trim is Positive By Stern VCG = m GM = m
----------------------------------------------------------------------------
Damage Stage Dmid Trim Heel FRB MaxGZ ARea PosRange VCG GM Critical VCGreq GMreq Range Range Case (m) (m) deg (m) (m) m*rad (deg) (m) (m) Criterio (m) (m)
INTACT CRITICAL VCGreq GMreq Draft Mid Trim Damage Case (m) (m) (m) (m)
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 26 OF 32
ALPHA MARINE CONSULTING LTD.
5.10. CONTACT PROCEDURES AND DETAILS IN THE EVENT OF DAMAGE
In the event of damage, the Master should alert the relevant parties, as appropriate, according to the lists below:
LIST OF SHIP INTEREST CONTACTS
Owners - Operators:
Address: Telephone: Facsimile:
Administration:
Address:
Telephone: Facsimile: Classification
Address: Telephone: Facsimile:
SAMPLE
M/V “VSLNAME” DAMAGE CONTROL BOOKLET PAGE 27 OF 32
ALPHA MARINE CONSULTING LTD.
LIST OF SHIP MANAGEMENT INTEREST CONTACTS
POSITION NAME TELEPHONE MOBILE
SAMPLE