DATA CENTER HUMIDIFICATION & COOLING

Humidification and Evaporative Cooling

i0522-66 Condair Data Centers brochure Danish AW.qxp_Layout 1 19/02/2014 08:55 Page 1

Page 2: DATA CENTER HUMIDIFICATION & COOLING · matter where they or their projects are located. Condair’s experience in many major global data center projects is brought to bear from initial

1Facebook, Sweden

Microsoft, US

Ebay, US Digital Reality, US

Hewlett Packard, USAT&T Mobile, US

RBC Royal Bank, CanadaHewlett Packard, Canada

Magnit, RussiaBarclays Bank, UK

Leibnitz Rechenzentrum , Germany

Deutsche Flugsicherung, Germany

Citi Group, UKMicrosoft, Ireland

NHN, South Korea

Metronode, Australia

China Construction Bank, China

Tianjin Sai De Data Center, China

Condair humidifiers are used in datacenters around the world to providehumidity control, prevent electrostaticdischarge (ESD) or offer high capacity,low cost cooling.

Some of the World’s largest brands puttheir trust in Condair humidificationsystems to help them fulfil their datacenters’ environmental controlstrategies.

TRUSTED TECHNOLOGY

Condair has manufacturing facilities in Canada, UK, Denmark, Germany, Switzerland and China as well aswholly-owned sales operations in 13countries and distributors in over 40 more.

The company has been serving theglobal data center industry for morethan 25 years. It has a dedicated Data

Centre Business Development Teamthat draws expertise from all corners ofthe organisation benefiting clients nomatter where they or their projects arelocated. Condair’s experience in manymajor global data center projects isbrought to bear from initial conceptdiscussions through to installation,commissioning and beyond.

GLOBAL EXPERTISE, LOCAL SOLUTIONS

i0522-66 Condair Data Centers brochure Danish AW.qxp_Layout 1 19/02/2014 08:55 Page 2

Page 3: DATA CENTER HUMIDIFICATION & COOLING · matter where they or their projects are located. Condair’s experience in many major global data center projects is brought to bear from initial

EVAPORATIVE COOLINGReducing PUE with low energy cooling

0 (32)0 (32)

0 (32)

5 (41)5 (41)

5 (41)

10 (50)10 (50)

10 (50)

15 (59)15 (59)

15 (59)

90% 80% 70% 60% 50% 40% 30%

20 (68)20 (68)

20 (68) 25 (77) 30 (86) 35 (95) 40 (104) 45 (113)

25 (77)

Recommended

A1

A2

A3 A4

25 (77)

Dry Bulb Temperature - ˚C (˚F)

© ASHREA graphic reformatted by Condair

Relative Humidity

Dew Point Tem

perature - ˚C (˚F)

Wet Bulb Temperature

˚C (˚F)

HUMIDIFICATIONMaintaining ASHRAE standards & combating ESD

Humidity control in data centers isrequired to prevent ESD fromdamaging electrical equipment.

For existing data centers ASHRAErecommends a humidity level of 5.5°Cdew point to 60%RH and an allowablerange of between 20-80%RH (see fig 1).

Condair has a comprehensive range of humidifiers to help data centeroperators meet ASHRAE’s standards,including innovative low energyadiabatic systems that can utilise heatfrom the data halls to minimisehumidifier energy consumption.

A single Condair adiabatic humidifiercan deliver up to 630kW of evaporativecooling while operating on less than0.3kW of electricity. This technologyincreases the cooling capacity of a datacenter’s ventilation system and extendsthe use of free air cooling into periodswhen the outside air alone is too warmto meet the required internal conditions.

Condair humidifiers are used to deliver low energy evaporative coolingdirectly to incoming fresh air as well asbeing incorporated into in-directevaporative cooling systems. Thesereduce the temperature of incoming airwithout raising its humidity byhumidifying exhaust air andtransferring its resultant cool thermal

energy into the incoming air via a heatrecovery system.

These low energy cooling techniquescan significantly reduce or eveneliminate the need for mechanicalcooling in data centers with a resultantdrop in PUE.

Fig 1

i0522-66 Condair Data Centers brochure Danish AW.qxp_Layout 1 19/02/2014 08:55 Page 3

Page 4: DATA CENTER HUMIDIFICATION & COOLING · matter where they or their projects are located. Condair’s experience in many major global data center projects is brought to bear from initial

Condair A/SMember of the Walter Meier GroupParallelvej 2, DK-8680 Ry, Tel: +45 8788 2100Gl. Holbækvej 6-8, DK-4200 Slagelse, Tel: +45 5850 1213www.condairsystems.com

Evaporative humidification Spray humidification

Steam humidification Hybrid humidification

Condair has a comprehensive range ofhumidification and evaporative coolingproducts to suit any data center’senvironmental control system.

SOLUTIONS FOR DATA CENTERS