Data Protector Fokustag 2019 19. November Böblingen Sebastian Koehler

Data Protector Fokustag...A Windows Installation Server must be part of the Data Protector cell to allow Remote Installation and Upgrades of Windows clients Installation source available

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Data Protector Fokustag 201919. November BöblingenSebastian Koehler

Technical Background

Primary- and secondary storage, high availability, clustering and replication as well as backup & recovery solutions.

Subject matter expert

MF Data Protector

HPE StoreOnce and Dell EMC Data Domain

HPE Tape Libraries

HPE 3PAR

HPE Serviceguard

Actively involved member

MF Data Protector Technical Advisory Board

HPE Worldwide Partner Ambassador

HPE Storage Championship Germany

Data Protector Practitioners Forum and Support Customer Forum

2

About The Speaker

EMEA Presales Data ProtectionMicro Focus

Sebastian Koehler

Data Protector 10.x Releases and Upgrade Path

Upgrade Options and Preparation

License Upgrade and Validation

Log Files Before and After Upgrade

Perform the Upgrade

Push and Local Client Installation and Upgrade

Secure Socket Communication

Importing Clients (Data Protector 10.x)

Clusters with Secure Communication

Scheduler and User Migration

Centralized omnirc management

3

Agenda

4

Data Protector 10.x Releases

September 28th, 2017Data Protector A.10.01

Version A.10.01.307

Patch bundle for A.10.00DPWINBDL_01001DPLNXBDL_01001DPUXBDL_01001

June 30th, 2017Data Protector A.10.00Version A.10.00.306

Full media kit

December 7th, 2017Data Protector A.10.02Version A.10.02.308

Patch bundle for 10.00:DPWINBDL_01002DPLNXBDL_01002DPUXBDL_01002

March 30th, 2018Data Protector A.10.03

Version A.10.03.181

Full media kit

May 31st, 2018Data Protector A.10.04Version A.10.03.182

Patch bundle for 10.03:DPWINBDL_01004DPLNXBDL_01004DPUXBDL_01004

September 17th, 2018Data Protector 2018.09

Version A.10.10.134

Full media kit

December 6st, 2018Data Protector 2018.11Version A.10.20.115

Full media kit

March 4th, 2019Data Protector 2019.03

Version A.10.30.105

Full media kit

2018 2019 2020

May 24th, 2019Data Protector 2019.05Version A.10.40.118

Full media kit

August 23th, 2019Data Protector 2019.08

Version A.10.50.125

Full media kit

5

Data Protector Upgrade Path

7.0x 8.0x 8.1x 9.0x 10.0x 10.10 10.20 10.30 10.40 10.50

6.2x

7.0x

8.0x

8.1x

9.0x

10.0x

10.10

10.20

10.30

10.40

Upgrade to VersionU

pgr

ade

fro

m V

ersi

on

Recommended Supported Not Supported

NOTE: This also applies to client upgrades

In-Place Upgrade

Single-step process where IDB and configuration data is retained, the Cell Manager name is not changed

Multi-step process if new hardware and/or operating system version should be used

Installation of an empty Cell Manager on a server (same platform, temporary name)

Migrate IDB and configuration files to the new system, be aware of service accounts used and file system permissions, junctions on Windows

Change hostname to old Cell Manager name

Perform the actual Upgrade in a seperate step

Migration (Green Field Installation)

Installation of a new Cell Manager on a server (physical or virtual) with a new name

Same or more recent Data Protector version

Migration of configuration data may vary

Config files (cell_info, specifications, etc.)

Clients (omnicc -update_all -force_cs)

Devices and Pools

Media (MCF export/import), DP 10.30 and later will retain Media Condition Factors

Only supported option for changing the Cell Manager platform (e.g. HP-UX to Linux)

6

Upgrade Options

Upgrade Licenses to 10.x

Data Protector 9.x will accept 10.x licenses

90 days Instant-On password after upgrade from 8.1x or 9.x to 10.x

Upgrade Planning, Review Documentation

Release Log Page

Support Matrix

Deprecation and Obsolescence list

Support Statement on Earlier Agent Versions

CM hardware requirements (min. 4x CPU and 16 GB RAM, Disk identical to DP 8.1x and 9.x)

Preparation Steps

Upgrade not longer supported clients to the latest possible agent version

Disable Encrypted Control Communication (ECC) in GUI or omnicc -encryption -disable -all

Remove the references to HP Fonts on Windows Cell Managers, requires reboot

Prepare changes in network firewalls

Clean-up logs before the upgrade

IDB consistency check using the command omnidbcheck -extended. Correct any errors before proceeding.

7

Upgrade Preparation (1/2)

Create a recent IDB full backup to a known media

Keep media.log and device configuration (omnidownload -library | -device)

Create an (offline) backup of the Cell Manager, e.g.

Windows Server Backup or tarball of /etc/opt/omni, /opt/omni and /var/opt/omni

VMware or HyperV snapshot if Cell Manager is a Virtual Machine

LVM Snapshot on Linux/UNIX or Windows VSS snapshot1

Storage snapshot if the IDB is stored on an external disk array

Prevent sessions from being executed during or after the upgrade

Cell Manager services must be up and running (see omnisv status) during the upgrade (required in 10.40 and later)

Place Cell Manager in maintenance mode using omnisv -maintenance 1

8

Upgrade Preparation (2/2)

1 Be careful with junctions in %DP_SDATA_DIR%\server\db80\pg\pg_tblspc

Keep omnicc -check_license -detail and omnicc -password_info output (old version)

Check products/quantity in support contract

Service Request (Licensing), please include:

http://mysupport.microfocus.com

Target Name (Cell Manager)

Target Cell Manager IPv4/IPv6 address

Content of lic.dat and omnicc output (above)

Micro Focus License Portal

https://entitlement.microfocus.com

Directly update products under support

9

License Upgrade and Validation

Validation:• Replace lic.dat on Cell Manager (old version)• Remove lic.ctx (tmp directory) if required• Run omnicc and compare results

Clean-up before the upgrade

Run omnisv stop to stop the services

Run omnisv start to start the services

Collect logs after (a failed) upgrade

Data Protector 10.40 and later will create installation/upgrade debugs (OB2DBG*.txt) in %DP_DATA_DIR\tmp or /tmp by default

On Windows also collect files from %TEMP%

NOTE: Only required in case if something goes wrong and support is needed.

10

Log Files Before and After Upgrade

%DP_DATA_DIR%\tmp/var/opt/omni/tmp

All

%DP_SDATA_DIR%\server\db80\pg\pg_log/var/opt/omni/server/db80/pg/pg_log

All

%DP_DATA_DIR%\log/var/opt/omni/log

LargeFiles

%DP_DATA_DIR%\log\server /var/opt/omni/log/server

LargeFiles

%DP_DATA_DIR%\log\AppServer/var/opt/omni/log/AppServer

All

Upgrade the Cell Manager and at least one GUI client

setup.exe or omnisetup.sh from corresponding Media Kit

Perform basic sanity checks using omnidbcheck -extended and in GUI (Devices & Media and IDB)

At this stage backups and restores should be possible

Upgrade the Installation Servers

setup.exe or omnisetup.sh from corresponding Media Kit

Upgrade the remaining GUI clients (locally or remote)

Upgrade the Media Agents and clients with StoreOnceSoftware installed

Use storeoncesoftware --stop_store --name=<StoreName> --force to stop stores before the upgrade

NOTE: Hotfix QCIM2A84565 to resolve an issue in StoreOnceSoftware in DP A.10.50 on Windows

11

Perform the Upgrade (1/2)

Upgrade clients with Online Integration Modules (Oracle, SAP, MSSQL, PostgreSQL, etc.)

NOTE: Upgrading clients where Exchange GRE is installed will cause an IISReset

The VMware GRE plug-in needs to be re-registered

Performed automatically during the Cell Manager upgrade or manually in GUI

Now uses a "Web User" and Secure Communication (no exception, automatically configured)

Upgrade the remaining clients

Clients that support an upgrade to the latest version

Upgrade the Backup Navigator or Reporting Server, if used

12

Perform the Upgrade (2/2)

A Windows Installation Server must be part of the Data Protector cell to allow Remote Installation and Upgrades of Windows clients

Installation source available via the OmniBack share on the installation server

Push installation is now using SMB signing when deploying new clients or during upgrade of 8.1x or 9.x clients

Data Protector 10.20 and later is using INET for upgrades (OB2UPGRADEOVERINET=1)

To allow the initial connect to the OmniBack share a user account must be configured on the Installation Server (omniinetpasswd)

omnirc option (Installation Server, 10.20 and later)

OB2UPGRADEOVERINET=0|1

OB2FWPASSTHRU=1

User Configuration (Installation Server)

omniinetpasswd -add DOMAIN\User

omniinetpasswd -inst_srv_user DOMAIN\User

omniinetpasswd -list

13

Push Installation and Upgrade (Windows)

A Linux/UNIX Installation Server1 must be part of the Data Protector cell to allow Remote Installation and Upgrades of Linux/UNIX clients

Installation source available in the directory /opt/omni/databases on the IS

Push installation is now using SSH by default

Operation can be performed by root or a sudo-enabled user account

Data Protector 10.20 and later is using INET for upgrades (OB2UPGRADEOVERINET=1)

If SSH keys are not pre-configured between the IS and the clients, then a password is required (e.g. ssh-copy-id) per client.

omnirc option (Installation Server, 10.20 and later)

OB2UPGRADEOVERINET=0|1

1 IS on HP-UX not available in Data Protector 10.50+

14

Push Installation and Upgrade (Linux/UNIX)

A local client installation/upgrade can be used if the remote installation is not working

Can be started from Windows Media Kit or directly from the OmniBack share

Make sure to specify Cell Manager name and confirm fingerprint (last step)

Use the INET port for your cell (e.g. 5555)

Client is automatically registered with Windows Firewall

Import the client after installation or run omnicc -update_host <Client> after an upgrade from 8.1x or 9.x

15

Local Client Installation and Upgrade (Windows)

A local client installation/upgrade can be used if the remote installation is not working

Can be started from Linux/HP-UX Media Kit

Make sure to specify Cell Manager name (-server) and confirm fingerprint (last step)

Use the INET port (-inetport) for your cell (e.g. 5555)

Firewall ports are not automatically opened

Import the client after installation or run omnicc -update_host <Client> after an upgrade from 8.1x or 9.x

linux:/tmp/LOCAL_INSTALL # ./omnisetup.sh -install da -server CM.domain.tld -inetport 5565

[...]

Certificate information:

- Hostname:CM.domain.tld

- Valid: from Jul 16 13:07:18 2019 GMT until Jul 13 13:07:18 2029 GMT

- Fingerprint: 12:b3:1a:a1:6e:96:64:30:bf:2f:74:33:21:d5:f1:37:ca:a5:bb:13:26:bf:52:fa:a2:67:b8:e0:7c:56:7e:d9

Do you want to continue (y/n)?y

Host 'CM.domain.com' configured for secure configuration successfully.

16

Local Client Installation and Upgrade (Linux/UNIX)

Secure communication (AES-256 bit, TLS 1.2) between client and Cell Manger

A self-signed client certificate is generated for each client (including the Cell Manager)

Fingerprints of all known clients are stored in the ssconfig file on the Cell Manager

The ssconfig file on each client only has the Cell Manager fingerprint

Client communication via the Data Protector INET port (e.g. 5565/TCP) only

The INET port must be open (IN and OUT) in the firewall

Ports previously used in OB2PORTRANGE may be closed after the client upgrade

omnicc -update_local_port <INET> can be used to quickly change the INET port on a client

17

Secure Socket Communication (1/2)

Cell Manager Client

Permitted

Rogue Client

Rejected

Secure communication between members

How to set it up?

A Secure Socket Communication trust is automatically configured

During a remote installation of a 10.x client

During a remote upgrade of a 8.1x or 9.x client to 10.x

Exceptions are configured for all clients in the cell_info during a CM upgrade (8.1x or 9.x)

Exporting a client from the cell will remove the SSC trust on Cell Manager and the client

Secure Data Communication

Encryption of payload (backup data) available in Data Protector 10.50 and later

Enabled or disabled with global option EnableSecureDataCommunication=0|1

Slightly higher CPU load and reduced performance

18

Secure Socket Communication (2/2)

Data Protector 10.x client (CM name was used and certificate accepted during installation)

Import in the GUI or omnicc -import_host <Client> [-accept_host] on the Cell Manager

Data Protector 10.x client (removed from the CM or installed without the CM name)

omnicc -secure_comm -configure_peer <CM> [-accept_host] on client

Import in the GUI or omnicc -import_host <Client> [-accept_host] on the Cell Manager

NOTE: A failed import may remove the certificate trust from the client!

Data Protector 9.x client (removed from the CM)

Import in the GUI (as OpenVMS host) or omnicc -import_openvms_host <Client> on the CM

NOTE: This will configure a SSC exception and import the client in one step

19

Importing Clients (Data Protector 10.x)

Each client is identified by an unique certificate (localhost_cert.pem and localhost_key.pem) and the fingerprint of the certificate is used to validate the client identity.

The same fingerprint may be used for different hostnames, but different fingerprints may not be used for the same hostname. Failing over a virtual hostname may break secure communication!

Solution: Use the same client certificate on all physical nodes in a Failover Cluster, Exchange DAG, SQL Server AO, Oracle RAC or any other HA environment where clients are imported as a "Virtual Host" with the purpose to be actviated on a different system.

20

Clusters with Secure Communication

Physical and Virtual Cluster Nodes

[root@node1 ~]# omnicc -secure_comm -get_fingerprintFingerprint : 1a:a3:4s:99:fx:11:41:...:d3:77

[root@node2 ~]# omnicc -secure_comm -get_fingerprintFingerprint : 85:af:6c:5a:f4:57:20:...:95:03

[root@vip1 ~]# omnicc -secure_comm -get_fingerprintFingerprint : 85:af:6c:5a:f4:57:20:...:95:03 node2

node1

vip1

Data Protector 10.00 introduced the new Consolidatd Scheduler (now Web Scheduler)

A combination of Legacy- and Advanced Scheduler storing all configuration in the Internal Database

Migration of Legacy Scheduler (schedule files) to Internal Database (JCE) was mandatory until DP 10.10

Schedule migration can be started using omnidbutil -migrate_schedules manually

The Leagacy Scheduler was re-introduced in Data Protector 10.20 in addition to Web Scheduler

Fallback to the Legacy Scheduler:

(Re)create schedules manually in Legacy Scheduler

Run omnidbutil -reinstate_legacy_schedules -force to rename *.migrate files and delete Web Schedules

Obtain and run omnijce2schedule.pl script to migrate omnidbutil -export_schedules -all output to Legacy Schedule files and delete associated Web Schedules

21

Scheduler Migration

User configuration is stored in the KeyCloak database (AppServer) in Data Protector 10.00

Enables LDAP authentication for users/groups and stores user information and access token

User migration runs during the 10.x upgrade or manually with the userMigrate.pl script

Direct modifcation of the UserList file is no longer supported

Use the GUI or omniusers command instead

Users with <ANY> statements are no longer valid for new entries in Data Protector 10.50 and later

A user that requires GUI access needs a password in KeyCloak

A randomized password is generated for all users in UserList during a upgrade

The password only needs to be known when using VMware GRE or the Data Protector WebUI

22

User Migration

Examples:omniusers -add -type W -usergroup admin -name "User" -group "DOM" -client "client.domain.tld" -setpass

omnicc -update_omnirc allows the remote manipulation of client specific configuration options across the entire cell

Available since Data Protector 10.03

It allows to push one omnirc option (key/value pair) at a time

Operating system type, specific agent installed or a set of hosts in a comma separated list or from a input file

23

Centralized omnirc management

Examples:omnicc -update_omnirc OB2NOTREEWALK -value 1 -client_os microsoftomnicc -update_omnirc OB2SQLBLOCKSIZE -value 65536 -module mssql70omnicc -update_omnirc OB2_DNSTIMEOUT -value 2