16
The next-generation Thermo Scientific HyPerforma Single- Use Mixer (S.U.M.) provides you with enhanced functionality, ease of use and efficiency. The complete HyPerforma S.U.M. system consists of a mixer tank with a motor controller, available in sizes of 50, 100, 200, 500, 1,000 and 2,000L with a 5:1 turndown mixing ratio. The redesigned HyPerforma S.U.M. maintains traditional stirred- tank mixer design principles with a directly-coupled motor impeller drive assembly and a cylindrical tank with a specific height-to- diameter ratio, allowing for quick turnaround time for liquid-to- liquid mixing and powder-to-liquid mixing. Critical upstream application steps • Media preparation. • Final formulation steps. • Buffer preparation. • Harvest vessels. • Large-volume mixing (up to 2,000L). Critical downstream application steps • Pooling and liquid transfer. • Product suspension. • Mixing and storing multiple batches. • Buffer preparation. • Viral inactivation. Thermo Scientific HyPerforma Single-Use Mixer The next generation of efficiency and performance DATA SHEET 200L HyPerforma Single-Use Mixer

DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

The next-generation Thermo Scientific™ HyPerforma™ Single-Use Mixer (S.U.M.) provides you with enhanced functionality, ease of use and efficiency. The complete HyPerforma S.U.M. system consists of a mixer tank with a motor controller, available in sizes of 50, 100, 200, 500, 1,000 and 2,000L with a 5:1 turndown mixing ratio. The redesigned HyPerforma S.U.M. maintains traditional stirred-tank mixer design principles with a directly-coupled motor impeller drive assembly and a cylindrical tank with a specific height-to-diameter ratio, allowing for quick turnaround time for liquid-to-liquid mixing and powder-to-liquid mixing.

Critical upstream application steps

• Media preparation.

• Final formulation steps.

• Buffer preparation.

• Harvest vessels.

• Large-volume mixing(up to 2,000L).

Critical downstream application steps

• Pooling and liquid transfer.

• Product suspension.

• Mixing and storingmultiple batches.

• Buffer preparation.

• Viral inactivation.

Thermo Scientific HyPerforma Single-Use MixerThe next generation of efficiency and performance

DATA SHEET 200L HyPerforma Single-Use Mixer

Page 2: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

HyPerforma S.U.M. options

• Powder hanger for 1kg, 5kg and25kg powder bags.

• AC and DC motor options;electrical box only available onAC option.

• 3x load cell weighing systemwith summing box (options fordisplaying signal output).

• Cable management system toorganize process tubing lines.

• Available in either water- jacketed or non-jacketed(no heat transfer) design.

• pH and conductivity probesand display.

• Open-top or closed-top Thermo Scientific™ BioProcess Container™ (BPC)design.

• BPC available in ThermoScientific™ CX5-14 Film andAegis™5-14 Film options.

Options outside of the above list may be reviewed with a Thermo Fisher Scientific sales representative and considered for customizations to the standard mixer design.

Ordering information

Standard S.U.M. hardware units Size Cat. No.

Non-jacketed, DC motor, without load cell 200L SUM0200.9001

Jacketed, DC motor, without load cell 200L SUM0200.9002

Non-jacketed, 120VAC, AC motor, without load cell 200L SUM0200.9003

Jacketed, 120VAC, AC motor, without load cell 200L SUM0200.9004

Non-jacketed, 240VAC, AC motor, without load cell 200L SUM0200.9005

Jacketed, 240VAC, AC motor, without load cell 200L SUM0200.9006

Note: Models without water jackets may have slightly different dimensions than the water-jacketed model shown here. See the drawings provided with your unit for exact dimensions for non-jacketed models. Non-jacketed models do not have the capability to heat or cool the liquid inside the tank.

Page 3: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

32

4

68

9

11

13

16

15

17

7

1019

18

14

1

Design features of the 50L, 100L and 200L S.U.M.

Front view of 50L, 100L and 200L water-jacketed S.U.M.

Back view of 50L, 100L and 200L water-jacketed S.U.M.

1. Powdertainer arm (optional)

2. Mixing assembly with shield

3. Bearing port receiver with clamp

4. Mixer motor

5. Stainless steel (grade 304) outer support container

6. Electrical control panel (optional)

7. Drive shaft (stored)

8. 3⁄8-inch dimpled jacket (side and bottom)

9. Probe access window

10. Probe hanger bracket

11. Cart assembly

12. Liquid sight windows

13. Standard tool set: 3⁄8-inch, 150 in.-lb. square torquewrench, load cell and motor cap lockout wrench

14. Bearing hub (for open-top mixing only)

15. Handles

16. Cutout for BPC loading

17. Bottom cutouts/pins for BPC attachmentand alignment

18. 1½-inch tri-clamp connection ports for water inlet/outlet (water-jacketed models only)

19. Casters (3 swiveling and 2 fixed)

20. Bleed valve (water-jacketed models only)

Note: Models without water jackets include the same features as water-jacketed models shown here, but without the jacket and inlet/outlet ports. Optional load cells and cable management system are not shown. See the accessories section for more information about these items.

12

20

Page 4: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Standard 200L S.U.M. dimensions — water-jacketed model

Standard 200L S.U.M. hardware

 200L S.U.M. specifications

 AC motor DC motor

Non-jacketed Jacketed Non-jacketed Jacketed

Flui

d ja

cket

Jacket area: full/half volume – 1.2m2 (13 ft.2)/0.69m2 (7.4 ft.2) – 1.2m2 (13 ft.2)/0.69m2 (7.4 ft.2)

Jacket volume – 6.5L (1.7 gal) – 6.5L (1.7 gal)

Jacket flow rate at 50psi – 99.4L/min (26.3 gal/min) – 99.4L/min (26.3 gal/min)

Process connection – 1-inch sanitary tri-clamp – 1-inch sanitary tri-clamp

TCU model: Maximum heating/cooling – TF2500: 2,800/2,500W – TF2500: 2,800/2,500W

Approximate liquid heat-up time (5°–37°C) – 3.4 hr – 3.4 hr

Approximate liquid chill-down time (37°–5°C) – 6.8 hr – 6.8 hr

Mis

c.

RTD or thermocouple, 3.18mm (1⁄8 in.) OD RTD: Pt-100 (standard)

Supp

ort c

onta

iner Overall width 94.8cm (37.3 in.) with e-box 59.7cm (23.5 in.) without e-box

Overall length 87.3cm (34.4 in.) with e-box 96.9cm (31.8 in.) without e-box

Overall height 175.3cm (69.0 in.)

Dry skid weight (mass) 237kg (523 lb.) 266kg (586 lb.) 237kg (523 lb.) 266kg (586 lb.)

Wet skid weight, rated working volume (mass) 437kg (964 lb.) 466kg (1,027 lb.) 437kg (964 lb.) 466kg (1,027 lb.)

Gene

ral

Ceiling height required for standard drive shaft loading 281.9cm (111 in.)

Ceiling height required for optional, non-standard 2-piece drive shaft loading

242.3cm (95.4 in.)

Electrical power supply requirement (voltage, phase, current)

120/240V single phase, 10A Dependent on controller

pH and dissolved oxygen (DO) probe, autoclavable type (AppliSens™, Broadley James™, Mettler Toledo™)

12mm diameter x 215–235mm insertion length x 13.5 PG (pipe) thread

Reco

mm

ende

d op

er-

atin

g

para

met

ers

Operating temperature range 2°–40°C ±0.1°C (36°–104°C ±0.2°F)

Motor speed 30–350rpm

Volume range 40–200L

Maximum static BPC pressure 0.03bar (0.5psi)

Maximum BPC pressure during operation 0.007bar (0.1psi)

Continuous operating time 21 days mixing time at nominal volume only

Top view Front view

240cm (94.4 in.) Powdertainer height

175cm (68.7 in.) Motor height

145cm (57.0 in.) Tank height

29cm (11.2 in.) Tank bottom19cm (7.6 in.) Cart height

0cm (0 in.)

80 cm (31.4 in.)Overall length

94 cm (37.0 in.)Overall width

97 cm (38.2 in.) Overall width

35 cm (13.8 in.) Electrical box width

62 cm (24.4 in.) Cart width

89 cm (34.9 in.) Overall length

66 cm (26.0 in.) Cart length

65cm (25.5 in.) Cart width

65cm (25.6 in.) Cart length

100cm (39.4 in.) Overall width

104cm (40.8 in.) Overall length

35cm (13.8 in.) Electrical box width

Page 5: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Ordering information

200L BPC Size Probe ports† Film type Cat. No.

Standard powder–liquid BPC 200L 0 CX5-14 SH30750.01

Standard powder–liquid BPC 200L 0 Aegis5-14 SH30973.02

Standard liquid–liquid BPC 200L 0 CX5-14 SH30753.01

Standard liquid–liquid BPC 200L 0 Aegis5-14 SH30983.02

Standard powder–liquid BPC† 200L 3 CX5-14 SH31054.02

Standard powder–liquid BPC† 200L 3 Aegis5-14 SH31053.02

Standard liquid–liquid BPC† 200L 3 CX5-14 SH31054.04

Standard liquid–liquid BPC† 200L 3 Aegis5-14 SH31053.04

†All 200L BPCs with probe ports are designed to allow probes to work properly at 5:1 turndown levels. These BPCs are only compatible with the HyPerforma hardware shown in this document. If you are using an older version of the S.U.M. hardware, do not use these items, but refer to the legacy S.U.M. user manual or data sheets.

Standard 200L BPC for powder–liquid applications without probe ports

3. Bottom drain

4. Powder addition port

 Line Description Tubing set (inner diameter x outer diameter x length) End treatment

1 Addition line 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) Plugged 12.7mm (½ in.) MPX body

2 Recirculation/sample line 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 137cm (54 in.) splits to12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 61cm (24 in.) and 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 30cm (12 in.)

Capped 12.7mm (½ in.) MPX insertPlugged 12.7mm (½ in.) MPX body

3 Bottom drain 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) Capped 12.7mm (½ in.) MPX body

4 Powder addition port 7.6mm (3 in.) sanitary fitting, tri-clamp Capped with gasket

Back face

1. Addition line

Impeller

2. Recirculation/sample lineFront face

Page 6: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Standard 200L BPC for liquid–liquid applications without probe ports

Front face

Back face

 Line Description Tubing set (inner diameter x outer diameter x length) End treatment

1 Bottom drain 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) Plugged 12.7mm (½ in.) MPX insert

2 Recirculation/sample line 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 137cm (54 in.) splits to12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 61cm (24 in.) and 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 30cm (12 in.)

Capped 12.7mm (½ in.) MPX insertPlugged 12.7mm (½ in.) MPX body

3 Fill line 19.1mm (3⁄4 in.) x 25.4mm (1 in.) C-Flex x 122cm (8 in.) 38.1mm (1½ in.) tri-clamp (SterilEnz™)

4 Vent filter 6.4mm (1⁄4 in.) x 12.7mm (1⁄2 in.) C-Flex x 10.2cm (4 in.) Sterile hydrophobic vent filter (0.2μm PVDF, Acro™ 50)

5 Addition line 9.5mm (3⁄8 in.) x 19.1mm (¾ in.) C-Flex x 61cm (24 in.) Plugged 9.5mm (3⁄8 in.) MPX insert

Impeller

5. Addition line4. Vent filter

3. Fill line

2. Recirculation/sample line

1. Bottom drain

Page 7: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Standard 200L BPC for powder–liquid applications with probe ports

Front face

Back face

 Line Description Tubing set (inner diameter x outer diameter x length) End treatment

1 Recirculation line 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 137cm (54 in.) splits to12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 61cm (24 in.) and 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 30cm (12 in.)

Capped 12.7mm (½ in.) MPX insertPlugged 12.7mm (½ in.) MPX body

2 Addition line 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) Plugged 12.7mm (½ in.) MPX insert

3–4 Probe ports (2) None Kleenpak™ aseptic connector KPCHT series (female)

5 Thermowell/ small-volume sample line

Thermowell adapter for 3.2mm (1⁄8 in.) diameter 3.2mm (1⁄8 in.) x 6.4mm (¼ in.) x 30cm (12 in.)

Luer and SmartSite™ valve port

6 Bottom drain 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) Capped 12.7mm (½ in.) MPX body

7 Powder addition port 7.6mm (3 in.) sanitary fitting, tri-clamp Cap with gasket

1. Recirculation line

2. Addition line

Impeller

5. Thermowell/small-volume sample line

3–4. Probe ports (2)

7. Powder addition port

6. Bottom drain

Page 8: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Standard 200L BPC for liquid–liquid applications with probe ports

Front face

Back face

Impeller

3. Thermowell/small-volume sample line

1–2. Probe ports (2)

8. Bottom drain

7. Addition line

6. Vent filter

5. Fill line4. Recirculation line

 Line Description Tubing set (inner diameter x outer diameter x length) End treatment

1-2 Probe ports (2) None Kleenpak aseptic connector KPCHT series (female)

3 Thermowell/small-volume sample line

Thermowell adapter for 3.2mm (1⁄8 in.) diameter 3.2mm (1⁄8 in.) x 6.4cm (1⁄4 in.) C-Flex x 30cm (1⁄2 in.)

Luer and SmartSite valve port

4 Recirculation line 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) splits to12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 61cm (24 in.) and 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 30cm (12 in.)

Capped 12.7mm (½ in.) MPX insertPlugged 12.7mm (½ in.) MPX body

5 Fill line 19.1mm (3⁄4 in.) x 25.4mm (1 in.) C-Flex x 122cm (8 in.) 38.1mm (1½ in.) tri-clamp (SterilEnz)

6 Vent filter 6.4mm (1⁄4 in.) x 12.7mm (1⁄2 in.) C-Flex x 10.2cm (4 in.) Sterile hydrophobic vent filter (0.2μm PVDF, Acro 50)

7 Addition line 9.5mm ( 3⁄8 in.) x 19.1mm (¾ in.) C-Flex x 61cm (24 in.) Plugged 12.7mm (½ in.) MPX insert

8 Bottom drain 12.7mm (½ in.) x 19.1mm (¾ in.) C-Flex x 122cm (48 in.) Plugged 9.5mm ( 3⁄8 in.) MPX insert

Page 9: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Standard open-top liners and impeller sleevesBottom drain

Ordering information

Description Size Cat. No.

Impeller sleeve for open-top mixing† 200L SH30749.08

†The bearing hub needed for open-top mixing is automatically supplied with the tank hardware.

Quick-connect fitting

Sleeve (¾ in. inner diameter tubing)

Impeller

Ordering information

Description Size Probe ports Film type Cat. No.

Standard open-top liner 200L 0 CX3-9 SH30762.01

Page 10: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Custom BPC products

BPC packaging

Category Options/capability Notes

Tubing type C-Flex, platinum-cured silicone, PVC, PharMed™, PharmaPure™. More information is available in the tubing selection guide.

Tubing size Ranges from 3.18mm (1⁄8 in.) to 25.4mm (1 in.) inner diameter in various lengths.

More information is available in the tubing selection guide.

Connectors Luer, Colder Products Company™ (CPC) quick connects, SIP connectors, tri-clamp, Kleenpak, SmartSite, Clave™, Lynx™ steam-thru, CPC steam-thru, Gore™ steam valve, Gore™ Mini TC, BioQuate™, SterilEnz end plug.

More information is available in the connection system selection guide. Note: the only option for probe port connections is Kleenpak.

Probe ports/line addition ports

Ports may be added if they are compatible with the hardware. The reusable probe port connection uses a Kleenpak connector.

Disposable sensors Pressure sensor: PendoTECH™ and Finesse Solutions™ (PendoTECH comes standard on 500L and 1,000L S.U.M.); DO and pH sensor: Finesse Solutions and PreSens™; pH sensor: Mettler Toledo.

Choice of qualified vendors available.

Port sizes Limited engineer-to-order customization only. Dependent on location in bag and fit with hardware (e.g., 1-inch ID port on harvest line).

Rearrangement of lines on existing ports

Limited customization possible, such as moving sample/thermo-well port to a probe tube port, or swapping exhaust outlet line with liquid lines.

Dependent on location in bag and fit with hardware.

Dip tube lines Limited customization possible. Length cannot interfere with impeller and shaft.

Filters on media and supplement inlets

Limited engineer-to-order customization only. Choice of filters used to sterilize incoming media or supplements are available.

Note: Not all options are available for all ports. It is not possible to customize port type, port location, chamber dimensions, or mixing assembly. For additional information, please see the selection guides in the BPC Catalog.

Outer packaging Supplied “flat-packed” with two polyethylene outer layers

Label Description, product code, lot number, expiry date on outer packaging and shipping container

Sterilization Irradiation (25 to 38kGy) inside outer packaging

Shipping container Durable cardboard carton

Documentation Certificate of analysis provided with each lot for each delivery

Page 11: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Channels for addition lines

Adjustable arm

Harvest line hook

Cable management system

HyPerforma S.U.M. options

Ordering information

Description Size Cat. No.

Cable management system 200L SV50992.02

Page 12: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Load cell optionsLoad cells are typically radially mounted in sets of three. The mounting location varies slightly for each size in order to allow easy access to the bottom drain or sparging mechanisms and tubing.

Mettler Toledo MTB load cell for 50L–1,000L S.U.M. units.

Load cell displaysHarsh mount load cell displays are available as an option for all HyPerforma S.U.M. systems. They are normally mounted on the electrical box or a wall and are available with four different interfaces.

Mettler Toledo IND331 harsh mount load cell display for all S.U.M. systems.

Ordering information

Description Interface Cat. No.

Mettler Toledo IND331 display, harsh mount style with 120VAC US line cord/plug

Analog (STD) SV50177.306

Mettler Toledo IND331 display, harsh mount style with 120VAC US line cord/plug

Allen-Bradley™ RIO SV50177.307

Mettler Toledo IND331 display, harsh mount style with 120VAC US line cord/plug

Device net SV50177.308

Mettler Toledo IND331 display, harsh mount style with 120VAC US line cord/plug

Ethernet/IP and Modbus TCP SV50177.309

Mettler Toledo IND331 display, harsh mount style with 120VAC US line cord/plug

Profibus SV50177.310

Ordering information

Description Size Cat. No.

3x load cell with summing box without display 200L SV50988.02

Page 13: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Powdertainer arm

pH and conductivity monitoring devices

Powdertainer hook

Powdertainer-to-BPC port clamp

Tank attachment mechanism

A Powdertainer arm is available as an option for powder–liquid applications. It holds the container of powder above the mixer and attaches it to the BPC with a clamp. The arm adjusts vertically and swivels to enable convenient lifting of the powdertainer onto the hanger.

Mettler Toledo pH and conductivity sensors with a display monitor are available in single pH, dual pH, and pH and conductivity configurations. The monitor is mounted on the post behind the electrical box and includes a color touch screen and control and alarm management features.

Ordering information

Description Size Cat. No.

Powdertainer arm for 50L–1,000L mixers 50L–1,000L SV51002.01

Ordering information

Description Cat. No.

Mettler Toledo pH monitoring device, single channel SV51004.01

Mettler Toledo pH monitoring device, dual channel SV51004.02

Mettler Toledo pH and conductivity monitoring device, dual channel SV51004.07

Page 14: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Autoclave tray and probe assemblyThe autoclave tray holds the electrochemical probes and bellows in place during the autoclave sterilization process. Design elements include the following:

• Fabricated from stainless steel.

• Plastic handle provides for easy transport right out of the autoclave.

• Positions probes on 15% incline for greater probe and membrane longevity.

• Restrains probe bellows from collapsing during sterilization.

• Probe holder accommodates two probes.

Probe assembly

Handle

Threaded probe attachment

Cable tie

Molded bellows cover

Probe clipsStainless steel probe clips are used to hold the probes in place on the S.U.M. tank. The independently moveable probe clips hang on a thin brace above the probe port tank cutout and are held in place by an adjustable spring plunger. The probes are inserted into the clip mechansim and held in place by a half-spring clip.

Ordering information

Description Cat. No.

Autoclave tray SV50177.01

4 probe clips SV50177.23

Ordering information

Description Cat. No.

Heavy-duty tubing clamp (single) SV20664.01

Heavy-duty tubing clamps (10-pack) SV20664.04

Heavy-duty tubing clampsHeavy-duty clamps are used for pinching off line sets that are not in use in order to prevent process fluids from escaping. Prior to sterile probe insertion, tubing clamps must be in place to close off probe ports.

Page 15: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Configuration table for made-to-order S.U.M. hardware

Single-Use Mixer SUM ####. X X X X X X X X X X X X

Vessel size

0050, 0100, 0200, 0500, 1000 or 2000 (4 digits in liters, followed by a dot)

1. Vessel type/material

A = Non-jacketed (304 SST) (standard) tank and cart are 304 SST

B = Jacketed (304 SST) (standard) tank and cart are 304 SST

C = Non-jacketed (316 SST) tank and cart are 316 SST

D = Jacketed (316 SST) tank and cart are 316 SST

2. Motor/electrical enclosure/mount

A = DC motor/no electrical enclosure

B = AC motor/no electrical enclosure

C = AC motor/120VAC electrical enclosure, right-hand configuration (standard)

D = AC motor/240VAC electrical enclosure, right-hand configuration (standard)

E = AC motor/120VAC electrical enclosure, left-hand configuration

F = AC motor/240VAC electrical enclosure, left-hand configuration

3. Drive shaft

A = 1-piece drive shaft (SST)

B = 2-piece drive shaft (SST)

C = 3-piece drive shaft (SST)

4. RTD

0 = No RTD

A = Single RTD, Pt-100, 60 in. Bulgin connector (standard)

B = Dual RTD, Pt-100, 120 in. DB9 connector x 120 in. open lead wires

C = Dual RTD, Pt-100, 120 in. Bulgin x 120 in. Bulgin connectors

D = Dual RTD, Pt-100, 120 in. DB9 x 60 in. Bulgin connectors

E = Dual RTD, Pt-100, 120 in. Bulgin x 120 in. LEMO connectors

F = Single RTD, Pt-100, 120 in. Bulgin connector

G = Dual RTD, Pt-100, 120 in. DB9 x 120 in. Bulgin connectors

H = Single RTD, Pt-100, 60 in. LEMO connector

5. Load cells and display

0 = No load cells

A = Loads cells, no display

B = Loads cells, wall mount display, analog output communication

C = Loads cells, wall mount display, Allen-Bradley communication

D = Load cells, wall mount display, device net communication

E = Loads cells, wall mount display, Modbus communication

F = Loads cells, wall mount display, Profibus communication

6. Powder arm assembly

0 = No powder arm assembly

A = Powder arm assembly

7. Cable management tree

0 = No cable management tree

A = Cable management tree, left-hand configuration

B = Cable management tree, right-hand configuration

8. Communication cable

0 = No communication cable

A = Communication cable

9. Monitoring device

0 = No monitoring device

A = pH monitoring device, single channel with display

B = pH monitoring device, dual channel with display

C = pH and conductivity monitoring device with display

10. Probe clip

0 = No probe clip

A = Probe clip (quantity of 4)

11. P&ID tags (predefined tags and locations, not custom)

0 = No P&ID tags

A = Standard P&ID tag option (predefined, not custom)

12. Pressure relief valve

0 = No pressure relief valve

A = Pressure relief valve (max. pressure set at 75psi)

B = Pressure relief valve with pressure indicator (max. pressure set at 75psi)

Page 16: DATA SHEET 200L HyPerforma Single-Use Mixer Thermo ...assets.thermofisher.com/TFS-Assets/BID/...(BPC) design. • BPC available in Thermo Scientific ™ CX5-14 Film and Aegis ™ 5-14

Find out more at thermofisher.com/sum

© 2015 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Allen Bradley is a trademark of Allen-Bradley Company. AppliSens is a trademark of Applikon B.V. Corporation. BioQuate and PreSens are trademarks of General Electric Company. Broadley James is a trademark of Broadley-James Corporation. Clave is a trademark of ICU Medical, Inc. Colder Products Company is a trademark of Dover Corporation. Finesse Solutions is a trademark of Finesse Solutions. Gore is a trademark of W. L. Gore & Associates. Kleenpak and Acro are trademarks of Pall Corporation. Lynx is a trademark of Merck KgAA. Mettler Toledo is a trademark of Mettler-Toledo AG. PendoTECH is a trademark of PendoTECH. PharMed and PharmaPure are trademarks of Saint-Gobain Performance Plastics Corporation. SmartSite is a trademark of Carefusion 303, Inc. SterilEnz is a trademark of PAW BioScience Products, Inc. CO210096 0715

In the United States:For customer service, call 1-800-766-7000To fax an order, use 1-800-926-1166To order online: lifetechnologies.com

In Canada:For customer service, call 1-800-234-7437To fax an order, use 1-800-463-2996To order online: lifetechnologies.ca