2
xEPI 2 Ethernet HART PROFIBUS DP PROFIBUS PA PROFIBUS Diagnosis Web Clients SMTP PLC Diagnosis Repeater Configuration Applications Diagnosis Applications Page 1 Data Sheet xEPI 2 The xEPI 2 enables access to PROFIBUS via Ethernet and provides diagnosis functions for continuous monitoring of PROFIBUS networks. It supports various standards and ap- plications for central field device configuration and for diagno- sis of PROFIBUS networks. APPLICATION The xEPI 2 can be used in the PROFIBUS network both passively without its own station address and as an active station. Failures are displayed in a clear, well-arranged format via Web interface. As a passive station, the xEPI 2 operates as data collector and analyses the cyclic data exchange of the PROFIBUS net- work. As an active station, the xEPI 2 operates as class 2 master (acyclic DP master) with its bus parameters and station address being assigned by the parent application. FUNCTIONS • Status overview of the entire installation • Navigation in detailed views of the single PROFIBUS net- works down to modular level • Error list with time stamp and plaintext diagnoses including tips for troubleshooting • Saving of up to 4,000 messages per xEPI 2 • Live List • Statistics of bus load and failure frequencies (e.g. repeat telegrams) • Configurable email alert in case of failures • Time synchronization with SNTP server or PC system time • Display and analysis of Siemens Diagnostic Repeaters (bus physics) • PROFIBUS access for the PROFIBUS Scope software • Master function (MCL 2) for PC-based applications (such as FDT frame application, Emerson's AMS Suite, TH OPC Server DP)

Data Sheet Page 1 - techvalue.cl · SMTP PLC Diagnosis Repeater ... Version February 2010 ... Data Sheet Page 2 Technical Data Order Information Scope of Delivery Contact Nominal

  • Upload
    doanthu

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Data Sheet Page 1 - techvalue.cl · SMTP PLC Diagnosis Repeater ... Version February 2010 ... Data Sheet Page 2 Technical Data Order Information Scope of Delivery Contact Nominal

xEPI 2

Eth

erne

t

HART

PR

OFI

BU

S D

P

PROFIBUS PA

PROFIBUS Diagnosis

Web Clients

SMTP

PLC

DiagnosisRepeater

Configuration Applications Diagnosis Applications

Page 1Data Sheet

xEPI 2The xEPI 2 enables access to PROFIBUS via Ethernet andprovides diagnosis functions for continuous monitoring ofPROFIBUS networks. It supports various standards and ap-plications for central field device configuration and for diagno-sis of PROFIBUS networks.

APPLICATION

The xEPI 2 can be used in the PROFIBUS network bothpassively without its own station address and as an activestation. Failures are displayed in a clear, well-arranged formatvia Web interface.As a passive station, the xEPI 2 operates as data collectorand analyses the cyclic data exchange of the PROFIBUS net-work.As an active station, the xEPI 2 operates as class 2 master(acyclic DP master) with its bus parameters and stationaddress being assigned by the parent application.

FUNCTIONS

• Status overview of the entire installation• Navigation in detailed views of the single PROFIBUS net-

works down to modular level• Error list with time stamp and plaintext diagnoses including

tips for troubleshooting• Saving of up to 4,000 messages per xEPI 2• Live List• Statistics of bus load and failure frequencies

(e.g. repeat telegrams)• Configurable email alert in case of failures• Time synchronization with SNTP server or PC system time• Display and analysis of Siemens Diagnostic Repeaters

(bus physics)• PROFIBUS access for the PROFIBUS Scope software• Master function (MCL 2) for PC-based applications

(such as FDT frame application, Emerson's AMS Suite, TH OPC Server DP)

Page 2: Data Sheet Page 1 - techvalue.cl · SMTP PLC Diagnosis Repeater ... Version February 2010 ... Data Sheet Page 2 Technical Data Order Information Scope of Delivery Contact Nominal

© Trebing + HimstedtAll brand and product names used in this document are trademarks or registered trademarks and legally protected as such, even if not explicitly labeled. | Version February 2010Trebing & Himstedt Prozeßautomation GmbH & Co. KG | W.-Hennemann-Str. 13 | 19061 Schwerin | Germany | Tel.: +49 385 39572-0 | Fax: +49 385 39572-22 | [email protected] | www.t-h.de

Data Sheet Page 2

Technical Data

Order Information

Scope of Delivery

Contact

Nominal Supply Voltage

Current Consumption

Ambient Temperature Range

Transfer Rate PROFIBUS TH OPC Server DP, AMS Suite, FDT

xEPI 2 PROFIBUS Diagnosis, PROFIBUS Scope

PROFIBUS Interface

Ethernet Interface

Mounting

Dimensions W x H x D

Weight

Certificate

xEPI 2

xEPI 2 hardware

Installation Guide

Per download at www.t-h.de

Release Note

Trebing + Himstedt DTM Library (includes CommDTM PROFIBUS DP-V1)

TACC - TH AMS Devcie Manager Communication Components (includes HART Over PROFIBUS)

System requirements

see Release Note xEPI 2 (www.t-h.de)

Optional

Mobile Connection Kit (Power supply, Ethernet cabel, PROFIBUS cable)

24 V DC (19.2 … 28.8)

max. 190 mA

0 … 50°C

max. 12 MBit/s

max. 1.5 MBit/s

RS 485

RJ-45 (10Base-T/100Base-TX)

35 mm DIN Top Hat Rail

22.5 x 99 x 114.5 mm

120 g

CE | UL

10002416

10002686

Phone: +49 385 39572-25

Email: [email protected]