41
1 Resi DataComm Copyright 2000 IDEAL Industries, Inc. KIMTECH DataComm Relevant Tools To order: 087-929-3178

DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

Embed Size (px)

Citation preview

Page 1: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

1Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

KIMTECH

DataComm Relevant Tools

To order: 087-929-3178

Page 2: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

2Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

DataComm ToolsUsed in the project of every field of Voice/Data/Video communication networksAlso used in the project of Security, Alarms, Sensors, Intercoms system

Page 3: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

3Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

The Physical Medium of Comm.

4-pair UTP/STP (Unshielded/Shield Twisted Pair) cable (Cat.5/5e/6 or higher )

Coax cable (75Ω, 50Ω)

Optical cable or fiber

Page 4: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

4Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Communications market pyramid

5% of job cost, 75% of the failures

NetworkHardware

Software

Cable

Termination

Passive Hardware

The use of quality tools & connectors help ensure the termination

Page 5: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

5Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

IDEAL CSTT - System Solution4 Things done to 3 kinds of cable

CutStripTerminateTest

Cable TypesTwisted PairCoaxialFiber Optic

Page 6: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

6Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Process Twisted pairs cable

Used in almost every new network installation today (except fiber)

Used in new telephone installations (Cat 3 minimum)

Page 7: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

7Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Termination types

Modular Plugs

Modular Jacks

Modular Patch Panels & Blocks

Page 8: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

8Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Modular Plugs

Least used type of terminationMost difficultMost frustratingMost time consumingUsed in:

Commercial Applications w/no Patch Panels, typically smaller installationsSome Residential Distribution Centers

Page 9: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

9Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Let’s pull out:

UTP CableRJ-45 PlugsUTP StripperData T-CutterCrimpMaster

Page F-12~14

Page 10: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

10Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Stripping UTP

45-165 UTP StripperAdjustable blade depth prevents nicks to copper conductorsReplaceable blade

Page 11: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

11Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Stripping UTP

Ring cable about 3” from end to score sheathing

Bend cable to separate at score mark,remove scrap sheathing (slug)

Pulling ripcord through sheathing assures that there will be no nicks in

center conductorCut away excess sheathing and ripcord

Page 12: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

12Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Terminating UTP

• Put all conductors in order, parallel and touching

2. Cut excess off, leaving NO MORE than ½”

3. Put connector on, seating all conductors fully

4. Crimp connector, using a ratcheting connector

Page 13: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

13Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Modular Plugs

IDC Contact Point(Insulation Displacement)

Primary Strain Relief(on sheathing)

Secondary Strain Relief(on conductors)

Conductors MUST be inserted past the

IDC point

Page 14: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

14Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Terminating UTP

Use a ratcheting-style crimper to terminate network connectionsAssures the same crimp every timeReduces failure rate tremendously

30-506 (Frame) page F-14

30-696 page F-11

Page 15: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

15Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Modular Jacks

• Place orange pair in corresponding slot with sheathing up against back of jack. DO NOT UNTWIST WIRES!

2. Push conductors into slots 3. Punch down each conductor, cutting edge out

4. Repeat procedure for other pairs separate where necessary

5. Terminated jack 6. Place dust caps over conductors

Page 16: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

16Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Modular Punchdowns

Used in telephone & data applications Cross ConnectsPatch PanelsModular Jacks

Page 17: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

17Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Modular punchdownsMost often used terminationEasiest to masterCan still be a great cause of termination failuresAdjustable high-low settingConvenient blade storageInterchangeable blades for:

11066BIXKrone

Page 18: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

18Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Process Coax cable

Page 19: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

19Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Coaxial geometry

Braiding needs to be equidistant from center conductor for signal integrity

Braiding

CenterConductorGood Bad

Page 20: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

20Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

These just won’t do…

Flattened Cable

Page 21: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

21Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

But these will

Curved cutting blades will reduce distortion of the cableData T-Cutters for Coax and UTP

Page 22: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

22Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Stripping Coax for F-style & BNC

1/4” Max 1”

Page F-12~14

For F-style

0.667”

0.24” 0.24” 0.187”

For BNC

Cut center conductor with35-060 CenterConductor Cutter

45-524 Coax Stripper

45-262 Stripmaster®

30-433 Combo Tool

Page 23: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

23Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Stripping coax with the Stripmaster®

1. Place cable in smaller hole ½” protruding 2. Squeeze handles together firmly & quickly

3. Place cable in larger hole ¼” protruding, squeeze 4. Stripped cable

Page 24: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

24Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

45-520 Coax Stripper

Quick and accurateReplaceable cassette bladesFully adjustableFor popular crimp BNC connectorsCan be used as F-style stripper by backing one blade out

Page 25: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

25Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Adjusting & Replacing Blade

3. Check by re-stripping cable.1. Remove hex wrench from handle

2. Insert wrench into adjusting grommets.Adjust by rotating 1/3 of way around at a time

Adjusting blade

•Pull front door open•Lift cassette up & out•Insert new cassette & close door

Replacing blade

Page 26: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

26Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Stripping for F-style

1. Set sliding windowto cable size

2. Place cable in stripper with 1/8” protruding 3. Rotate stripper in

direction of lettering

4. Remove cable from stripper 5. Remove slugs 6. Stripped cable for F- style

Page 27: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

27Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Stripping for BNC

1. Set sliding window to cable size

2. Place cable in stripper with1/4” protruding

3. Rotate stripper indirection of lettering

4. Remove cable from stripper 5. Remove 1st two slugs 6. Remove 3rd slug by bending cable

3 segments

Page 28: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

28Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Center Conductor Cutter 35-060

1. Stripped cable

2. Lay side of cutter against white dielectric, ensure center conductor length is

0.187”(about 4.8mm)

3. Finished cable

Cut center conductor with35-060 CenterConductor Cutter

Page 29: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

29Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

About “F” Connectors

IDEAL has these connectors, see page F-22

One-pieceMost preferred, easiest installation

Two-pieceMore pullout strength

Twist-onWhat twists on will twist off…

The number one cause of video distribution problemsis tightening F connectors finger tight. Tighten them with an F connector tool.

Page 30: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

30Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

F-Connector installation Tool

Using leverage to install an F connector will seat every connector properlyMost video signal problems are caused by loose connections. Tighten all connectors with an F-Connector tool.

35-046

Page 31: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

31Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Coax Strip & Crimp Tool

Cuts, Strips & Crimps RG-6 & RG-59No need to carry separate toolsGood for occasional contractor use30-433

Page 32: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

32Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Terminating coax - CrimpMaster™

Consistency & repeatabilityMore leverage, less installer fatigueThe same crimp every time28 interchangeable diesFor the installer with more than an occasional crimp to do

The best Crimp tool

Page F-14

Page 33: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

33Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Terminating BNC Connectors

1. Close CrimpMaster to 1/8” open

2. Place center contactpin point down intosmallest crimp nest

Wrong side up

3. Place center conductor all the wayinto center contact pin and crimp

4. Rotate dielectric to bend backbraiding

Page 34: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

34Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Terminating BNC Connectors

1. Seat connector body onto dielectric, underneath the braiding, listen for click of captive contact pin

2. Seat the ferrule against theconnector body with equal, opposing force

3. Squeeze handles together completely 4. Finished Connector

Page 35: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

35Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

The newest connector and tools

•Compression F&BNC connectors

•Fast and reliable solution to Coax projects

•Different types for different cables

•Permanent connection, connector never loose

Page F-15

30-603 30-703 30-633

Page 36: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

36Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Yes, they’re used…

No, they shouldn’t

Page 37: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

37Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Best tools, work best!IDEAL offers various “System Solution” kits

Page F-16~19

Page 38: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

38Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

It’s time to talk about Optical

And God said, Let there be light: and there was light.

--Genesis The Old Testament

Page 39: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

39Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

Processing Optical Fiber

Cut - Strip - Clean - Scribe - Polish - Terminate - Inspect - Test

Watch the Video

Page 40: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

40Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

TEST & TESTERSThe last step of CSTT system solution

VerificationCertification

See DataComm Tester Presentation

Page 41: DataComm KIMTECH DataCommRelevant Tools Datacom Tools.pdf · 41 Resi DataComm Copyright 2000 IDEAL Industries, Inc. Questions Questions More detailed information, PLS look at Catalog

41Resi

DataComm

Copyright 2000 IDEAL Industries, Inc.

QuestionsQuestions

More detailed information, PLS look at Catalog part F