9
Datasheet Control unit for Electrically Height-Adjustable Furniture Part number: LIBERTYcontrol-2M3-LAZ: 10.000086 LIBERTYcontrol-2M3-LAZ Product Rev 5 Document Rev 1 LOGIC home

Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

Datasheet

Control unit for Electrically Height-Adjustable Furniture Part number: LIBERTYcontrol-2M3-LAZ: 10.000086

LIBERTYcontrol-2M3-LAZ Product Rev 5 Document Rev 1

LOGIC home

Page 2: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

2

Contents 1 Features .............................................................................................................................................. 32 Dimensions ......................................................................................................................................... 43 Drilling template .................................................................................................................................. 44 Technical Data .................................................................................................................................... 55 Parameter Settings ............................................................................................................................. 56 Pin assignment ................................................................................................................................... 6

6.1 Interface description ................................................................................................................... 66.2 Hand wand socket ...................................................................................................................... 66.3 Actuator socket .......................................................................................................................... 76.4 Power socket + Combination outputs ......................................................................................... 7

7 Type Label .......................................................................................................................................... 88 Order Code ......................................................................................................................................... 89 Final disposal ...................................................................................................................................... 910 Manufacturer Information .................................................................................................................... 9 Changelog

Revision Change Log Date

Rev0_0 Initial Revision 27.10.2014

Rev1_0 Standby power < 0.5W ESD caps removed

24.11.2014

Rev1_1 Manufacturer information updated 17.03.2015

Rev2_0 Improved software:

- Support for other power supplies - General software improvements

18.06.2015

Rev3_0

Improved hardware: - Securely suppress ringing

Datasheet update: - 4M3 information added

18.06.2015

Rev4_0 LibertyControl-XM3-LAZ seperrated by La-Z-Boy part number Firmware update for LCPLUS System

07.09.2015

Rev4_1 Dimension update 24.09.2015

Rev4_2 M1 and M2 description swapped in 3.1.1 Updated control box dimensions

14.10.2015

Rev4_3 Replaced drawing due to insufficient resolution 14.04.2016

Rev5_0 Improved thermal characteristics of MOSFET driver 21.11.2016

Rev 5 1 Maße und Type label korrigiert

Page 3: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

3

1 Features • Control of 2 actuators (up/down) with soft start and stop (LIBERTcontrol-2M3-LAZ) • Control of 1 massage group with up to 6 massage units with 3 intensity levels (HM system only) • Control of 2 heating pads with 2 intensity levels each (HM system only) • Intelligent duty cycle management • Colour coded plugs

Attention: Do not open the device! Risk of electric shock!

WARNING Avoid damaging the plugs and cables. Never operate this unit if cables are damaged. Use only the provided cables. Connect the plug only to an electrical source matching the type label. Never operate the control box until it is mounted and fully installed. CAUTION Do not open this unit. Uninsulated parts within the products enclosure may expose you to dangerous voltage. Servicing may only be carried out by qualified personnel. Contact LOGICDATA. To prevent fire or shock hazard, do not expose this device to rain or moisture. Unplug the power cord before cleaning this unit. Only use a soft cloth, avoid abrasive cleaners. If you are not using the device for a long period of time, it is recommended to unplug the power cord. If strange smells or fume occur, unplug the power cord immediately. Contact LOGICDATA.

Page 4: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

4

2 Dimensions

3 Drilling template

184,0 ± 0,25 mm

204,2 ± 0,25 mm

40,3

± 0

,1 m

m

68,7

± 0

,1 m

m

Ø 7,0 ± 0,05 mm

Ø 13,5 ± 0,05 mm

Page 5: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

5

4 Technical Data Input (Power circuit) 29 V DC / max. 8 A Input (18V emergency circuit) (typical) (maximum)(max. continuous load) (peak load <100ms)

18 V DC 19 V DC2.5 A 4.5 A

Standby power <0.5 W Output (Motor channels M1-M4) Max. 6 A @ 29 V DC output voltage, 10 %

duty cycle (2 min on / 18 min off) Output (Combination KM1-KM3) Max. 1 A (RMS) @ 29 V DC output voltage,

75 % duty cycle (90 min on / 30 min off) Operating voltage for electronics 5 V DC ± 10 % Hall sensor supply voltage 5 V DC ± 10 % Ambient temperature during operation +5 – +40 °C Storage temperature -25 – +70 °C Relative humidity (for operation) 10 – 85 % (non-condensing, max. dew point

at +27 °C) Relative humidity (for storage) 5 – 90 % (non-condensing, max. dew point at

+38 °C) Dimensions (l x w x h) Tolerances according to DIN 16742 TG3

204.2 mm × 68.7 mm × 36.5 mm

Weight (typical) 200 g

5 Parameter Settings Motor channel current thresholds:

System M1 Legrest

M2 Lift/Recline

M3 Lumbar

M4 Headrest

Massage Heating

Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A N/A 2 A 3 A

Note: If loads attached to the LIBERTYcontrol-2M3-LAZ shall operate at the same time, the maximum current must not exceed 8 A. Exceedance will be prevented by the current measurement inside the LIBERTYcontrol-2M3-LAZ. Additionally, the current is limited by the rating of the power supply attached to the LIBERTYcontrol-2M3-LAZ and this limit can be lower than 8 A.

Page 6: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

6

6 Pin assignment The LIBERTYcontrol-2M3-LAZ unit has the following sockets:

6.1 Interface description � Hand wand socket

� Power socket + combination outputs (KM1-KM3)

� M1: Legrest Actuator socket

� M2: Lift/Recline Actuator socket

6.2 Hand wand socket

� � � �

HS M1 M2 PWR+HM

LIBERTYcontrol-2M3-z

1………….Serial input RxD

2……….…Parallel input HS3

3……….…Parallel input HS1

4……….…Parallel input HS4

5……….…Parallel input HS2

6……….…Serial output TxD

7……….…+5VDC

8……….…Bat+ (18VDC)

Sa/b……...GND

LIBERTYcontrol-2M3-LAZ

Page 7: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

7

6.3 Actuator socket

1 and 7…MotorPower_A2 and 4…MotorPower_B3………...Hall supply +5V5………...GND6………...Limit switch 18………...Hall sensor lineSh……....Limit switch 2

shield

DIN41524262° angle

Caution: To prevent damage of the unit, use only motors/ motor cables suitable for LOGICDATA motor controls.

6.4 Power socket + Combination outputs

1....TEMP 6….POWER ON/OFF2....+18V 7….+35V3....GND 8….GND4....+35V 9….PWATCH5…+12V 10….KEYFront View (connector on PCB)

1 2 3 48 7 69

510

1 and 7 …MotorPower_A

2 and 4….MotorPower_B

3……….…Hall supply +5V

5…….……GND

6…….……Limit switch / Hall sensor 2

8…….……Hall sensor 1 Sh….…….Limit switch 2

1….HM 2 2….+18V 3….GND 4….POWER (+29V) 5…. HM 3

6….HM Common 7….POWER (+29V) 8….GND 9…. HM 1 10….BUTTON

Page 8: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

8

7 Type Label

The serial number contains:

• Logicdata production code (first 5 numbers) • Date code (the next 4 numbers) • Running number (last numbers)

Figure: Portion of S/N that contains date code

8 Order Code

LIBERTYcontrol – 2M3 – LAZ

Page 9: Datasheet LIBERTYcontrol-2M3-LAZ 5 1 - LOGICDATAlogicdata.net/.../uploads/2017/05/Datasheet_LIBERTYcontrol-2M3-LAZ_5_1.pdf · Basic 3.2 A 3.5 A N/A N/A N/A N/A HM 3.2 A 3.5 A N/A

9

9 Final disposal When you no longer require the system, please note the following for disposal:

Note: ensure eco-friendly disposal of all the control unit components (separate the plastic and electronic parts for collection).

Also, ensure eco-friendly disposal of all the other components (pinch protection strip, drives, cables, etc.).

10 Manufacturer Information LOGICDATA North America, Inc. 1525 Gezon Parkway SW, Suite C

Grand Rapids, MI 49509

USA

Tel: +1 (616) 328 8841

E-mail: [email protected]

http://www.logicdata.net/na

LOGICDATA Electronic & Software Entwicklungs GmbH

Wirtschaftspark 18

8530 Deutschlandsberg - Austria

Tel: +43 (0)3462 5198 0

Fax: +43 (0)3462 5198 530

E-mail: [email protected]

http://www.logicdata.net