7
DataSheet SIGLENT Series Probe

DataSheet SIGLENT Series Probe - Batronix€¦ · Offset Setting function Yes (Set in test mode) Null Terminate Load 1MΩ Null Power Supply USB 5V/1A Adapter 9V DC Power Probe …

Embed Size (px)

Citation preview

DataSheetSIGLENT Series Probe

Parameter PB470 PP510 PP215 PP430

Attenuation Rate 1X/10X 1X/10X 1X/10X 1X/10X

Bandwidth 1X: DC-6MHz10X: DC-70MHz

1X: DC-6MHz10X: DC-100MHz

1X: DC-6MHz10X: DC-150MHz

1X: DC-6MHz10X: DC-300MHz

Input Impedance 1MΩ/10MΩ 1MΩ/10MΩ 1MΩ/10MΩ 1MΩ/10MΩ

Input Capacitance 1X: 85pF-120pF10X: 18pF-22pF

1X: 85pF-120pF10X: 18pF-22pF

1X: 85pF-120pF10X: 16pF-20pF

1X: 46pF10X: 12pF

Compensation Range 15pF-45pF 10pF-30pF 10pF-35pF 10pF-35pF

Input Voltage 1X: <300Vpp10X: <600Vpp

1X: <300Vpp10X: <600Vpp

1X: <300Vpp10X: <600Vpp

1X: <300Vpp10X: <600Vpp

Operation Temp -15℃ -75℃ -15℃ -75℃ -15℃ -75℃ -15℃ -40℃

Cable Length 120 cm 120 cm 120 cm 120 cm

Weight 50 g 50 g 50 g 50 g

Parameter PB925 SP2030A SP3025A SP3050A

Attenuation Rate 10X 10X 10X 10X

Bandwidth DC-250MHz DC-300MHz DC-250MHz DC-500MHz

Input Impedance 10MΩ 10MΩ±2% 10MΩ 10MΩ

Input Capacitance 16pF 12pF 12pF 11pF

Compensation Range 10pF-35pF 9pF-25pF 10pF-30pF 8pF-20pF

Input Voltage < 600V CAT III<1000V CAT II < 600V DC+Peak AC < 400V rms CAT II < 400V rms CAT II

Operation Temp 0℃ -50℃ 0℃ -50℃ 0℃ -50℃ 0℃ -50℃

Cable Length 120 cm 130 cm 120 cm 120 cm

Weight 55g 55g 55g 55g

Parameter ZS1500 ZS1000

Bandwidth 1.5GHz 1GHz

Input Impedance 1MΩ 1MΩ

Input Capacitance 0.9pF 0.9pFInput Dynamic State ±8V ±8V

Offset Range ±12V ±12VNon-destructiveVoltage Range 20V 20V

Interface ProBus ProBus

Cable Length 130 cm 130 cm

Weight 50 g 50 g

Model

Model

Model

Passive Probe

Active Probe

Parameter CP5030 CP5030A CP5150 CP5500

Bandwidth DC-50MHz DC-100MHz DC-12MHz DC-5MHz

Rise time ≤7nS ≤3.5nS ≤29nS ≤70nS

Max.effective value of AC 30 Arms 30 Arms 150 Arms 500 Arms

Peak-Peak Value 50 A 50 A 300 A 750 A

Range 5A(1X)/30A(10X) 5A(1X)/30A(10X) 30A(1X)/150A(10X) 75A(1X)/500A(10X)

Overload Value5A(≥5A) 5A(≥5A) 30A(≥30A) 75A(≥50A)

30A(≥50A) 30A(≥50A) 150A(≥300A) 500A(≥500A)

Current Transfer Ratio5A(1V/A) 5A(1V/A) 30A(0.1V/A) 75A(0.1V/A)

30A(0.1V/A) 30A(0.1V/A) 150A(0.01V/A) 500A(0.01V/A)

MeasurementResolution

5A(1mA) 5A(1mA) 30A(5mA) 75A(5mA)

30A(10mA) 30A(10mA) 150A(50mA) 500A(50mA)

DC Accuracy5A(±1%±1mA) 5A(±1%±1mA) 30A(±1%±10mA) 75A(±1%±10mA)

30A(±1%±10mA) 30A(±1%±10mA) 150A(±1%±100mA) 500A(±1%±100mA)

Power Supply DC 12V/1.2AMax. rated voltageto earth 300V CAT III 300V CAT III 600V CAT II

Conductor Diameter Max. 5mm 20mm

Cable Length 1m 1.5m

BNC Length 100cm

Weight 240g 500g 510g

Parameter CP4020 CP4050 CP4070 CP4070A

Bandwidth DC-100kHz DC-1MHz DC-150kHz DC-300kHz

Rise time ≤3.5μS ≤0.35μS ≤2.3μS ≤1.2μS

Max.effective value of AC 20 Arms 50 Arms 70 Arms 70 Arms

Peak-Peak Value 60 A 140 A 200 A 200 A

Range Switch 50mV/A; 5mV/A 500mV/A; 50mV/A 50mV/A; 5mV/A 100mV/A; 10mV/A

DC Accuracy

±2%(0.4A-10ApK) at 50mV/A±2%(1A-60ApK) at 5mV/A

±3%±20mA(20mA-14ApK) at 500mV/A;±4%±200mA(200mA-100ApK) at 50mV/A;±15% max(100A-140ApK) at 50mV/A

±2%(0.4A-10ApK) at 50mV/A±2%(1A-200ApK) at 5mV/A

±3%±50mA(50mA-10ApK) at 100mV/A; ±4%±50mA(500mA-40ApK) at 10mV/A; ±15% max(40A-200ApK) at 10mV/A

Power Supply 9V batteryMax. rated voltageto earth 300V CAT III 600V CAT II

Conductor Size 10.3mm 10.3mm 10.3mm 11mm

Cable Length 200cm 100cm 100cm 100cm

Weight 310g 310 310g 260g

Model

Model

Current Probe

Parameter DPB5150 DPB5150A DPB5700 DPB5700A DPB4080

Bandwidth DC-70MHz DC-100MHz DC-70MHz DC-100MHz DC-50MHz

Rise time ≤5ns ≤3.5ns ≤5ns ≤3.5ns ≤7ns

DC Accuracy ±2% ±2% ±2% ±2% ±1%

Attenuation Ratio 50X/500XMax Differential TestVoltage (DC + Peak AC)

50X: 150V500X: 1500V

100X: 700V1000X: 7000V

10X: 80V100X: 800V

Max input commonMode voltage (voltage-to-earth Vrms)

600V CATIII1000V CATII

1000V CATIII2300V CATII 800Vrms

Input Impedance

Single-ended to ground 5MΩ 5MΩ 20MΩ 20MΩ 27 MΩ

Two inputs 10MΩ 10MΩ 40MΩ 40MΩ 54MΩ

Input Capacitance

Single-ended to ground <4pF <4pF <5pF <5pF <2.3pF

Two inputs < 2pF <2pF < 2.5pF < 2.5pF < 1.2pF

CMRR

DC > 80dB >80dB > 80dB > 80dB > 80dB

100kHz > 60dB >60dB > 60dB > 60dB > 60dB

1MHz > 50dB >50dB > 50dB > 50dB > 50dB

Noise (Vrms) 50X: <50mV500X: <50mV

100X: < 200mV1000X: < 1.2V Null

Propagation Delay 18ns±1ns

Bandwidth limit ≥-3dB@5MHz NullDifferential overvoltageDetection level

50X: ≥150V500X: ≥1500V

100X: ≥700V1000X: ≥7000V Null

Overload indicator(red light) Yes Null

Overload Alarm Yes (Can shut up manually) Null

Automatic Save Yes Null

Offset Setting function Yes (Set in test mode) Null

Terminate Load 1MΩ Null

Power Supply USB 5V/1A Adapter 9V DC Power

Probe body dimensions 195*65*28 mm 165*69*26 mm

Probe body weight Approx 188 g Approx 190 g Approx 500g

Model

High Voltage Differential Probe

High Voltage Probe

Parameter HPB4010

Bandwidth DC-40MHz

Rise time ≤7nS

Max. Measurement Voltage DC: 0~10KV DC AC: pulse ≦ 20KV peak to peak; sine wave ≦ 7KV rms

Single / Noise DC≥60dB(1KHz),≥50dB(1MHz)

Attenuation Ratio 1:1000

Input Impedance 100MΩ±1%

Input Capacitance 3.0pF±0.5pF

Compensation Range 5pF~50pF

Cable length 2.0meter (±0.2M)

Temperature Coefficient ≤200PPM/℃

AccuracyDC ±2% (DC to 10KV)

±3% (Above 10KV)AC ±3% (1KHz/1KV) -3dB 50MHz

Operating Temperature 0~50℃

Storage Temperature -20~+70℃

Weight / Volume 250g/Ф75×340 mm

Model

Parameter SPL2016 Parameter SPL3016

Channels 16 Channels 16

Input Impedance 100KΩ||18PF Input Impedance 100KΩ||5PF

Working Voltage ±5V Max. Input Voltage ±3Vpp

Non-destructive Voltage ±50V Sample Rate 500MSa/sUser defined threshold range -3V~3V User defined threshold

range ±10V in 20mv steps

Threshold Selections TTL (1.5V), COMS (2.5V), 3.3V_LVCOMS (1.65V), 2.5V_LVCOS(1.25V) Threshold Selections TTL (1.4V), 5V COMS (+2.5V), ECL(-1.3V),

User definedThreshold Accuracy ±100mV Threshold Accuracy ± (3%*Threshold+100mv)

Delay Window 600mV Input Dynamic Range ±20 V

Min. Input Voltage Swing 800mV Min. Input Voltage Swing 800mVpp

Input level Limit

TTL (0V≤VL≤0.8V;2.4V≤VH≤5V)CMOS(0V≤VL≤1.5V;3.5V≤VH≤5V)3.3V_LVCOMS(0V≤VL≤0.7V;2V≤VH≤3.3V)2.5V_LVCOMS(0V≤VL≤0.7V;1.7V≤VH≤2.5V)

Threshold Groupings Pod 2: D15-D8Pod 1: D7-D0

Cable length 100CM±2CM Max. Input Frequency 125 MHz

Line length 18CM±1CM (data line) , 12CM±1CM (ground lead) Record length 10M

Max. Data rate

Probe 300 Mbps Min. Detectable Pulse Width 4ns

Line 100 Mbps Channel Skew ±(1digital sample interval)

Parameter SPL1008

Channels 8

Input Impedance 100KΩ||18PF

Working Voltage ±5Vpp

Non-destructive Voltage ±40VppUser defined threshold range -3V~3V

Threshold Selections TTL (1.5V), COMS (1.65V), 3.3V_LVCOMS(1.65V), 2.5V_LVCOS(1.25V)

Threshold Accuracy ±400mV

Delay Window 600mVpp

Min. Input Voltage Swing 800mVpp

Input level Limit

TTL (0V≤VL≤0.8V;2.4V≤VH≤5V)CMOS(0V≤VL≤1.5V;3.5V≤VH≤5V)3.3V_LVCOMS(0V≤VL≤0.7V;2V≤VH≤3.3V)2.5V_LVCOMS(0V≤VL≤0.7V;1.7V≤VH≤2.5V)

Cable length 80CM±2CM

Max. Data rate 120 Mbps

Timing sampling rate 500 Mbps

Status sampling rate 60 Mbps

Minimum input slew rate 75mV/μS

Plus Width Resolution

TTL: 15 nS

CMOS: 15 nS

LVCMOS 3.3V: 15 nS

Logic Probe

Model Model

Model

Parameter SRF5030-1 SRF5030-2 SRF5030-3 SRF5030-4

Frequency Range 30MHz to 3 GHz 30MHz to 3 GHz 30MHz to 2 GHz 30MHz to 3 GHz

Resolution 25mm 10mm 5mm 2mm

Application

It can be used at a distance of up to 10 cm from the units. The probe detects the spat ia l distr ibut ion of HF magnetic fields in devices and assemblies and allows the user to draw conclusions with regard to disturbance emissions.Frequency range:30MHz to 3GHz

It is suitable for measurements up to 3 cm. Interference sources can belocalized by detecting the distribution and orientation of the field, thereforeenabling a more exact use of higherresolution probes. Frequency range: 30MHz to 3GHz

It is suitable for measurements up to 3 cm. Interference sources can belocalized by detecting the distribution and orientation of the field, thereforeenabling a more exact use of higherresolution probes. Frequency range: 30MHz to 3GHz

It is designed for the detection of magnetic fields which are emitted vertically from the surface of PCBs and is thus ideal for investigating current loops. The probe allows the measurement in conf ined board areas (between large controller components, for example - resolution approx. 2 mm).Frequency range: 30MHz to 3GHz

Near Field Probe

Model

Headquarter:SIGLENT TECHNOLOGIES CO., LTD.Add: Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China. Tel: + 86 755 3661 5186Fax: + 86 755 3359 1582Email: [email protected]; Website: http://www.siglent.com/ens/

USA:SIGLENT Technologies America, Inc6557 Cochran Rd Solon, Ohio 44139Tel: 440-398-5800Toll Free: 877-515-5551Fax: 440-399-1211Email: [email protected]: www.siglentamerica.com

Europe:SIGLENT TECHNOLOGIES EUROPE GmbH ADD: Liebigstrasse 2-20, Gebaeude 14, 22113 Hamburg Germany Tel: +49(0)-819-95946Fax: +49(0)-819-95947Email: [email protected]: www.siglenteu.com

About SIGLENT

SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of test &measurement Instruments.

SIGLENT began to research and develop the Digital Oscilloscope independently in 2002. After a decade of development products have included digital oscilloscopes, isolated handheld oscilloscopes, function/arbitrary waveform generators, digital multimeters, DC power supplies, spectrum analyzers, and other general purpose test instrumentation. Since SIGLENTs first oscilloscope, the ADS 7000 series produced in 2005, SIGLENT has maintained the highest annual growth rate and has been the fastest developing DSO manufacturer over the past 10 years. Nowadays, SIGLENT Technologies is the leading manufacturer of oscilloscopes by shipments in China.

Follow us on Facebook: SiglentTech

DataSheetSIGLENT Series Probe