20
® Table of Contents Page Description . . . . . . . . . . . . . . . . . . . . . . . 1 Specifications . . . . . . . . . . . . . . . . . . . . . 1 Introduction . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . 1 Product Features . . . . . . . . . . . . . . . . . . 2 General Safety Information . . . . . . . . 2-3 Assembly . . . . . . . . . . . . . . . . . . . . . . . 4-5 Operation . . . . . . . . . . . . . . . . . . . . . . 5-8 Fuels . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 Overview of Heater Design. . . . . . . . . 6 Fueling Your Heater . . . . . . . . . . . . . . 6 Ventilation . . . . . . . . . . . . . . . . . . . . . . 7 Long-Term Storage . . . . . . . . . . . . . 7-8 Maintenance . . . . . . . . . . . . . . . . . . . 8-12 Replacing Fuse . . . . . . . . . . . . . . . . . . . 12 Repair Parts Illustration Models 3VE48G, 3VE49G, 3VE50H, 3VE51H . . . 14 Repair Parts List Models 3VE48G, 3VE49G, 3VE50H, 3VE51H . 14-15 Repair Parts Illustration Model 3VE52I . . . . . . . . . . . . . . . . . . . . . . . . . 16 Repair Parts List Model 3VE52I . . . . . 17 Repair Parts List, Wheels and Handles . . . . . . . . . . . . . . . . . . . . . . . . . 18 Troubleshooting Chart . . . . . . . . . . . . 19 Warranty Information . . . . . . . . . . . . . 20 Introduction Please read this USER’S MANUAL carefully. It will show you how to assemble, maintain and operate this heater safely and efficiently to obtain the full benefits of its many features. Consumer: Retain these instructions for future reference. Unpacking 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check all items for shipping damage. If heater is damaged, promptly inform dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Description Dayton Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I heaters are 50,000 to 210,000 BTU/Hr heaters. These heaters use 1-K Kerosene (see Operation section for alternative fuels) for combustion, and electricity to run the fan. It is primarily intended for temporary heating of well ventilated buildings under construction, alteration, or repair. This heater may be used in agricultural, industrial and com- mercial environments. Figure 1 – Models 3VE48G and 3VE49G Figure 2 – Models 3VE50H, 3VE51H and 3VE52I Specifications ELECTRICAL SPECIFICATIONS Electrical Model Input Amperage Fuse Spark Plug Gap 3VE48G 120V, 60 Hz 1.6 125V/8 amp .140” (3.5mm) 3VE49G 120V, 60 Hz 1.6 125V/8 amp .140” (3.5mm) 3VE50H 120V, 60 Hz 2.5 125V/8 amp .140” (3.5mm) 3VE51H 120V, 60 Hz 3.2 125V/8 amp .140” (3.5mm) 120V, 60 Hz 3.7 125V/8 amp .140” (3.5mm) GENERAL SPECIFICATIONS t h g i e W e z i S l e u F k n a T l e u F p m u P f o e p y T Model Fuel Input Rating Pressure Capacity Consumption L x W x H (Inches) Lbs. (kg) 1-K Kerosene 50,000 BTU/Hr 3.8 PSI 5.0 Gallons .38 Gal/Hr 32 x 11 3 /4 x 16 3 /4 27.6 (12.5) 1-K Kerosene 75,000 BTU/Hr 3.8 PSI 5.0 Gallons .57 Gal/Hr 32 x 11 3 /4 x 16 3 /4 27.6 (12.5) 1-K Kerosene 125,000 BTU/Hr 5.5 PSI 10.0 Gallons .95 Gal/Hr 36 1 /10x 21 1 /2 x 24 6 /10 56.4 (25.6) 1-K Kerosene 170,000 BTU/Hr 6.5 PSI 13.0 Gallons 1.3 Gal/Hr 41 8 /10x 23 1 /10 x 26 1 /10 8 /10x 23 1 /10 x 26 1 /10 62.8 (28.5) 1-K Kerosene 210,000 BTU/Hr 8.5 PSI 13.0 Gallons 1.6 Gal/Hr 41 64.4 (29.2) E N G L I S H E S P A Ñ O L F R A N Ç A I S 3VE52I 3VE48G 3VE49G 3VE50H 3VE51H 3VE52I IMKFAD-HDW Printed in the U.S.A Wiring Diagrams . . . . . . . . . . . . . . . . . 13

Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

Embed Size (px)

Citation preview

Page 1: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

®

Table of Contents PageDescription . . . . . . . . . . . . . . . . . . . . . . . 1Specifications . . . . . . . . . . . . . . . . . . . . . 1Introduction . . . . . . . . . . . . . . . . . . . . . . 1Unpacking . . . . . . . . . . . . . . . . . . . . . . . 1Product Features . . . . . . . . . . . . . . . . . . 2General Safety Information . . . . . . . . 2-3Assembly . . . . . . . . . . . . . . . . . . . . . . . 4-5Operation . . . . . . . . . . . . . . . . . . . . . . 5-8

Fuels . . . . . . . . . . . . . . . . . . . . . . . . . 5-6Overview of Heater Design. . . . . . . . . 6Fueling Your Heater . . . . . . . . . . . . . . 6Ventilation . . . . . . . . . . . . . . . . . . . . . . 7Long-Term Storage . . . . . . . . . . . . . 7-8

Maintenance . . . . . . . . . . . . . . . . . . . 8-12Replacing Fuse . . . . . . . . . . . . . . . . . . . 12

Repair Parts Illustration Models 3VE48G, 3VE49G, 3VE50H, 3VE51H . . . 14Repair Parts List Models 3VE48G, 3VE49G, 3VE50H, 3VE51H . 14-15Repair Parts Illustration Model 3VE52I .. . . . . . . . . . . . . . . . . . . . . . . . 16Repair Parts List Model 3VE52I . . . . . 17Repair Parts List, Wheels and Handles . . . . . . . . . . . . . . . . . . . . . . . . . 18Troubleshooting Chart . . . . . . . . . . . . 19Warranty Information . . . . . . . . . . . . . 20

IntroductionPlease read this USER’S MANUALcarefully. It will show you how toassemble, maintain and operate thisheater safely and efficiently to obtainthe full benefits of its many features.

Consumer: Retain these instructions for future reference.

Unpacking1. Remove all packing items applied to

heater for shipment.

2. Remove all items from carton.

3. Check all items for shipping damage. Ifheater is damaged, promptly informdealer where you purchased heater.

Dayton® Portable Oil-Fired Heaters

Operating Instructions & Parts Manual 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/orproperty damage! Retain instructions for future reference.

DescriptionDayton Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I heaters are 50,000 to210,000 BTU/Hr heaters. These heaters use 1-K Kerosene (see Operation section for alternative fuels) for combustion, and electricity to run the fan. It is primarilyintended for temporary heating of well ventilated buildings under construction,alteration, or repair. This heater may be used in agricultural, industrial and com-mercial environments.

Figure 1 – Models 3VE48G and 3VE49G

Figure 2 – Models 3VE50H, 3VE51H and3VE52I

SpecificationsELECTRICAL SPECIFICATIONS

ElectricalModel Input Amperage Fuse Spark Plug Gap

3VE48G 120V, 60 Hz 1.6 125V/8 amp .140” (3.5mm)

3VE49G 120V, 60 Hz 1.6 125V/8 amp .140” (3.5mm)

3VE50H 120V, 60 Hz 2.5 125V/8 amp .140” (3.5mm)

3VE51H 120V, 60 Hz 3.2 125V/8 amp .140” (3.5mm)

120V, 60 Hz 3.7 125V/8 amp .140” (3.5mm)

GENERAL SPECIFICATIONSthgieWeziSleuFknaT leuFpmuPfo epyT

Model Fuel Input Rating Pressure Capacity Consumption L x W x H (Inches) Lbs. (kg)

1-K Kerosene 50,000 BTU/Hr 3.8 PSI 5.0 Gallons .38 Gal/Hr 32 x 113/4 x 163/4 27.6 (12.5)

1-K Kerosene 75,000 BTU/Hr 3.8 PSI 5.0 Gallons .57 Gal/Hr 32 x 113/4 x 163/4 27.6 (12.5)

1-K Kerosene 125,000 BTU/Hr 5.5 PSI 10.0 Gallons .95 Gal/Hr 36 1/10x 21 1/2 x 24 6 /10 56.4 (25.6)

1-K Kerosene 170,000 BTU/Hr 6.5 PSI 13.0 Gallons 1.3 Gal/Hr 41 8/10x 23 1 /10 x 26 1 /10

8/10x 23 1 /10 x 26 1 /10

62.8 (28.5)

1-K Kerosene 210,000 BTU/Hr 8.5 PSI 13.0 Gallons 1.6 Gal/Hr 41 64.4 (29.2)

ENGLISH

ESPAÑOL

FRANÇAIS

3VE52I

3VE48G

3VE49G

3VE50H

3VE51H

3VE52I

IMKFAD-HDW

Printed in the U.S.A

Wiring Diagrams . . . . . . . . . . . . . . . . . 13

Page 2: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

2

Dayton Operating Instructions and Parts Manual

Dayton® Portable Oil-Fired Heaters3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

3VE50H3VE51H3VE52I

H 24 6 /10” 26 1 /10”

” 41 8 /10”L 36 1/10

W 21 1/2“ 231/32”

Dimensions

Figure 3 – Heater Dimensions

Figure 4 – Models 3VE48G and 3VE49G Features Figure 5 – Models 3VE50H, 3VE51H and 3VE52I Features

Models 3VE48G and 3VE49G

Models 3VE50H, 3VE51H and 3VE52I

General Safety InformationIndicates an im -minen tly hazardous

situation which, if not avoided, WILLresult in death or serious injury.

Indicates a poten -tially hazardous

situation which, if not avoided, COULDresult in death or serious injury.

Indicates a poten -tially hazardous

situa tion which, if not avoided, MAYresult in minor or moderate injury.

Before using thisheater, please read

this USER’S MANUAL very carefully. ThisUSER’S MANUAL has been designed toinstruct you as to the proper manner inwhich to assemble, maintain, store, andmost importantly, how to operate theheater in a safe and efficient manner.

Never leave theheater unattended

while burning!

Improper use of thisheater can result in

serious injury or death from burns, fire,explosion, electrical shock, and/orcarbon monoxide poisoning.

For optimal performance of this heater,it is strongly suggested that 1-K kero senebe used. 1-K kerosene has been refinedto virtually eliminate contami nants, suchas sulfur, which can cause a rotten eggodor during the operation of the heater.

DANGER

WARNING

WARNING

CAUTION

WARNING

DANGER

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Fan Guard

Hot Air Outlet

Lower Shell

Fuel TankSide Cover

LampThermostat Knob(3VE49G model only)

Power/Reset SwitchPower Cord

Upper ShellHandle

Pressure Gauge

Cord Wrap

Fuel Gauge

Fuel Cap

Hot Air Outlet

Lower Shell

Fuel Gauge

Fuel Cap

LampSide Cover

Room Temp. Display

ThermostatKnob

Power/Reset Switch

Power Cord(Piggy back)

Cord Wrap

Pressure Gauge

Handle Rear

Handle Front

Upper Shell

Product Features

ENGLISH

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

32"

WL

H

11 3/4"

16 3/4"

Page 3: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

3

For Technical Support or Troubleshooting, Call: 1-800-Grainger ®

General Safety Information(Continued)

Risk of Indoor Air Pollution!

- Use this heater only in well ventilatedareas! Provide at least a three squarefoot (2,800 sq. cm) opening of outsideair for every 100,000 BTU/hr of heaterrating.

- People with breathing problems shouldconsult a physician before using theheater.

- Carbon Monoxide Poisoning: Earlysigns of carbon monoxide poisoningresemble flu-like symptoms such asheadaches, dizziness, and/or nausea. Ifyou have these symptoms, your heatermay not be working properly.

- Get fresh air at once! Have the heaterserviced. Some people are more affectedby carbon monoxide than others. Theseinclude pregnant women, those withheart or lung problems, anemia, orthose under the influence of alcohol, or at high altitudes.

- Never use this heater in living orsleeping areas.

Risk of Burns/Fire/Explosion!

- NEVER use fuels such as gasoline,benzene, paint thinners, or other oilcompounds in this heater (RISK OFFIRE OR EXPLOSION).

- NEVER use this heater where flam -mable vapors may be present.

- NEVER refill the heater’s fuel tankwhile heater is operating or still hot.This heater is EXTREMELY HOT whilein operation.

- Keep all combustible materials awayfrom this heater.

Minimum ClearancesOutlet 8 feet (250 cm)Sides, Top and Rear 4 feet (125 cm)

- NEVER block air inlet (rear) or air outlet(front) of heater.

- NEVER use duct work in front or atrear of heater.

- NEVER move or handle heater whilestill hot.

- NEVER transport heater with fuel in its tank.

When used with optional thermostat or if equipped with a thermostat, theheater may start at any time.

- ALWAYS locate heater on a stable andlevel surface.

- ALWAYS keep children and animalsaway from heater.

- Use 1-K kerosene in this heater. #1/#2 diesel/fuel oil, JET A or JP-8 fuels are suitable substitutes.

- Bulk fuel storage should be a minimumof 25 ft. from heaters, torches, portablegenerators, or other sources of ignition.All fuel storage should be in accordancewith federal, state, or local authoritieshaving jurisdiction.

Risk of ElectricShock!

- Use only the electrical power (voltageand frequency) specified on the modelplate of the heater. Use only a three -prong, grounded outlet and extensioncord.

- ALWAYS install the heater so that it isnot directly exposed to water spray,rain, dripping water, or wind.

- ALWAYS unplug the heater when notin use.

CALIFORNIA RESIDENTS:

This heater produces carbonmonoxide, which is listed by the Stateof California as a reproductive toxinunder Proposition 65.

MASSACHUSETTS RESIDENTS:

Massachusetts state law prohibits the use of this heater in any buildingwhich is used in whole or in part forhuman habitation. Use of this heatingdevice in Massachusetts requires local fire dept. permit (M.E.L.C. 148,Section 10A).

CANADIAN RESIDENTS:

Use of this heater shall be in accor -dance with authorities having juris -diction and CSA Standard B139.

NEW YORK CITY RESIDENTS:

For use only at construction sites inaccordance with applicable NYC codesunder NYCFD certificate of approval#5034 and 5037.

WARNING

WARNING

WARNING

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52IDayton Operating Instructions and Parts Manual

ENGLISH

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

However, #1/#2 diesel/fuel oil, JET A or JP-8 fuels may also be used if 1-K kerosene is notavailable. Be advised that these fuels do not burn as clean as 1-K kerosene, and care should be taken to provide more fresh air ventilation to accommodate any added contaminants that may be added to the heated space. Use any fuel other than 1-K kerosene may result in more periodic maintenance.

Page 4: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

4

Dayton Operating Instructions and Parts Manual

Dayton® Portable Oil-Fired Heaters

Assembly

I25EV3H15EV3H05EV3G94EV3 ,G84EV3ledoM

Wheel Support Frame No Yes Yes Yes

seYseYseYoNsleehW

seYseYseYoNeldnaH-tnorF

seYseYseYoNeldnaH-raeR

seYseYseYoNThreaded Axle

oNoNoNseYeldnaH

seYseYseYseYparW droC

Hardware Kit: HW-KFA1021 No Yes Yes Yes

Figure 6 – Component Identification

Front Handle

Rear Handle

Threaded Axle

Wheel Support Frame

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Handle Cord Wraps

3VE48G / 3VE49G Models

ENGLISH

Cap Nuts S

Hardware Kit : HW-KFA1021(10" Flat Free)

WheelsCord Wraps

Screws Flange Screws

Nuts Bushings Cap Nuts L

3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

3VE50H / 3VE51H / 3VE52I Models

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Page 5: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

Assembly (Continued)FOR MODELS 3VE48G AND 3VE49GONLY

FOR MODELS 3VE50H, 3VE51H AND3VE52I ONLY

TOOLS REQUIRED

- Medium Phillips Screwdriver.- 3/4 inch socket or adjustable wrenchAssembling Handle & Wheel and Cord Wrap1. Slide threaded axle through the rear section of the wheel support frame.

2. Slide one axle bushing on to each side of the axle. Slide one wheel on to each side of the axle. Attach one cap nut on to each side of the threaded axle and tighten well.3. Place heater on wheel support frame. Align the holes on fuel tank flange with holes on wheel support frame.4. Position the Handles on top of fuel tank flange. Insert screws through handles, fuel tank flange and wheel support frames as shown in Figure 8 and attach nut finger tight after each screw is inserted. 5. Align the hole on the handles with the mounting hole on the Cord Wrap. Insert Screws through Cord Wrap, handles and attach nut finger tight after each screw is inserted.6. After all screws are inserted, tighten nuts firmly.

Do not operateheater without

support frame fully assembled to tank.

FUELSFor optimal performance of this heater,it is strongly suggested that 1-K kero -sene be used. 1-K kerosene has beenrefined to virtually eliminate contami -nants, such as sulfur, which can cause arotten egg odor during the operationof the heater. However, #1/#2 diesel/fuel oil, JET A or JP-8 fuels may also be used if 1-K kerosene is not available. Be advisedthat these fuels do not burn as clean as1-k kerosene, and care should be takento provide more fresh air ventilation toaccommodate any added contaminants

CAUTION

Figure 7 – Handle and Cord WrapInstallation 3VE48G and3VE49G only

For Technical Support or Troubleshooting, Call: 1-800-Grainger ®

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52IDayton Operating Instructions and Parts Manual

Figure 8 – Models 3VE50H, 3VE51H and 3VE52I Assembly

Front Handle

Hot Air Outlet

Wheel

Cap Nut L

Cap Nut S

Fuel Tank Flange

Nut

Wheel SupportFrame

Flange Screw

Cord Wrap

Screw

Rear Handle

Air Inlet

Threaded Axle

Wheel Bushing

ENGLISH

5

TOOLS REQUIRED- Medium Phillips screwdriver.1. Lift front guard for arrow direction

and make sure that guard’s wedged portion fits into the slit hole on the upper housing.

2. Remove the pre-assembled screws on the shell upper and side cover.

3. Align the holes in upper housing withtwo mounting holes on the handle asshown in Figure 7.

4. Secure handle with the screws removed.

5. Insert cord wrap into the rectangle holes on the supporter and align the hole on the cord wrap with the mounting hole on the side cover as shown in Figure 7.

6. Secure cord wrap with the screws removed.

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

HandleScrew Front Guard

Wedged

Slit Hole

Side Cover

Cord Wrap

Screw

Shell Upper

Remove Screws

Remove Screws

Portion

Page 6: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

6

Operation (Continued)

NOTE: Kerosene should only be storedin a blue container that is clearly mark ed “kerosene”. Never store kero -sene in a red container. Red is associ -ated with gasoline.

- NEVER store kerosene in the livingspace. Kerosene should be stored in awell ventilated area outside the livingarea.

- NEVER use fuel such as gasoline,benzene, alcohol, white gas, campstove fuel, paint thinners, or other oilcompounds in this heater (THESE AREVOLATILE FUELS THAT CAN CAUSE AFIRE OR EXPLOSION).

- NEVER store kerosene in directsunlight or near a source of heat.

- NEVER use kerosene that has beenstored from one season to the next.Kerosene deteriorates over time. OLDKEROSENE WILL NOT BURN PROPERLYIN THIS HEATER.

- Use 1-K kerosene in this heater. #1/#2 diesel/fuel oil, JET A or JP-8 fuels are suitable substitutes.OVERVIEW OF HEATER DESIGN

Fuel System: This heater is equippedwith an electric air pump that forces airthrough the air line connected to thefuel intake, and then through a nozzlein the burner head. When air passes infront of the fuel intake, it causes fuel torise from the tank and into the burnernozzle.

This fuel and air mixture is then sprayedinto the combustion chamber in a fine mist.

SureFire Ignition: The electronic ignitorsends voltage to a specially designedspark plug. The spark plug ignites thefuel and air mixture described above.

The Air System: The heavy duty motorturns a fan that forces air into andaround the combustion chamber. Here,the air is heated and then forced outthe front of the heater.

THE SAFETY SYSTEM

Temperature Limit Control: This heateris equipped with a Temperature LimitControl designed to turn the heater offshould the internal temperature rise toan unsafe level. If this device activatesand turns your heater off, it may requireservice.

Once the temperature falls below thereset temperature, you will be able tostart your heater.

Electrical System Protection: Thisheater’s electrical system is protected by a fuse mounted to the PCB Assemblythat protects it and other electrical

components from damage. If yourheater fails to operate, check this fusefirst and replace as needed. Refer toSpecification chart on page 1.

Flame-Out Sensor: Utilizes a photocellto monitor the flame in burn chamberduring normal operation. It will causethe heater to shut off should the burnerflame extinguish.

FUELING YOUR HEATER

Never fill the heater fuel tank in theliving space: fill the tank outdoors.

Do not overfill your heater and be sureheater is level.

Never refill fuel tankwhen heater is

operating or still hot.

IMPORTANT: REGARDING FIRSTIGNITION OF HEATER. The first time you light the heater, it should be doneOUTDOORS. This allows the oils, etc.,used in manufacturing heater to beburned off outside.

WARNING

Dayton Operating Instructions and Parts Manual

Dayton® Portable Oil-Fired Heaters

Model

3VE50H/3VE51H

3VE48G/3VE49G

3VE52I

Internal Shut-Off Temp.+/-10 Degrees

230°F/110°C

176°F/80°C

194°F/90°C

Reset Temp. +/-10 Degrees

194°F/90°C

122°F/50°C

140°F/60°C

Figure 9 – Overview of Heater Design

For Technical Support or Troubleshooting, Call: 1-800-Grainger

ENGLISH

3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52INEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

that may be added to the heated space.#2 diesel/fuel oil heavier than 1-K kerosene in extreme cold temperatures without nontoxic anti-icer additives will not ignite properly.

Page 7: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

Electric Outlet

Cover

Operation (Continued)VENTILATION

Risk of indoor airpollution. Use heater

only in well ventilated areas.

Provide a fresh air opening of at leastthree (3) square feet (2,800 sq. cm) foreach 100,000 BTU/Hr. rating. Provideextra fresh air if more heaters are being used.

Example: A 3VE52I heater requires oneof the following :

1. A two-car garage door raised sixinches (15.24 cm).

2. A single-car garage door raised nineinches (22.86 cm).

3. Two, thirty inch (76.20 cm) windowsraised fifteen inches (38.1 cm).

TO START HEATER

4. 3VE48G model Only: Push powerswitch to “ON” position. Power Lampwill light and heater will start.

5. 3VE49G, 3VE50H, 3VE51H, and 3VE52I models: Turn thermostat control knobto desired setting and push powerswitch to “ON” position. Power lampwill light and heater will start.

NOTE: Room Temp. display indicates asfollowing:

- When room temp. is less than 0°F:“lo”.

- When room temp. is between 0°Fand 99°F: Indicates in figure.

- When room temp is less than 99°F:“Hi”.

If heater does not start, the thermostatsetting may be too low. TurnTHERMOSTAT CONTROL KNOB tohigher position to start heater. If heaterstill does not start, turn power switch to“OFF” and then to “ON” position (SeeFigure 10). If heater still does not start,see Troubleshooting on page 18.

NOTE: The major electrical componentsof this heater are protected by a safetyfuse mounted to the PCB board. If yourheater fails to start, check this fuse firstand replace as necessary. You shouldalso check your power source to insurethat proper voltage and frequency arebeing supplied to the heater.

TO SHUT DOWN HEATER

Turn switch to “OFF” and unplug powercord.

TO RESTART HEATER

1. Wait 10 seconds after stoppingheater.

2. Repeat steps under, “TO STARTHEATER.”

PIGGYBACK POWER CORD

Shock Hazard!Always cover electric

outlet when not in use. Don’t plug anduse an appliance of more than 5Acurrent in this outlet.

LONG-TERM STORAGE OF YOURHEATER

FUEL TANK DRAIN

1. Drain fuel tank through fuel cap opening. (For Models 3VE48G, 3VE49G Only)2. Remove fuel drain bolt from rear bottom side of fuel tank using 3/4” socket or adjustable wrench and drain. (For Models 3VE50H 3VE51H, 3VE52I only)3. Using a small amount of kerosene, swirl and rinse the inside of the tank. NEVER mix water with the keroseneas it will cause rust inside the tank.Pour the kerosene out making sure that you remove it all.

WARNING

CAUTION

7

For Technical Support or Troubleshooting, Call: 1-800-Grainger ®

Dayton Operating Instructions and Parts Manual

Model 3VE48G Model 3VE49GModel 3VE50H, 3VE51H, 3VE52I

Lamp

Power/ResetSwitch

Power/ResetSwitch

Power/ResetSwitch

Lamp Lamp

ThermostatControl Knob

ThermostatControl Knob

Room Temp. Display

Figure 10 – Controls for All Models

Figure 11 - Piggyback Power Cord

ENGLISH

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

1. Fill fuel tank with fuel.

NOTE : Kerosene is recommended when the temperature drops below 0� � ) to prevent ignition delay or failure.2. Attach fuel cap.3. Plug power cord into three

prong,grounded extension cord. Extensioncord must be at least six feet long.- Extension Cord Wire SizeRequire-

ments:- 6 to 100 feet (1.8 to 30.53 meters)

long, use 16 AWG conductor. - 101 to 200 feet (30.8 to 61 meters)

long, use 14 AWG conductor.

NOTE : In cold weather, ignition may be improved by holding a finger over the end of the relief valve or block fanguard in half with newspaper etc. until the heater ignites.

Page 8: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

IMPORTANT : Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

4. Reinstall fuel cap. Properly dispose of old and dirty fuel. (For Models 3VE48G, 3VE49G Only)

5. Reinstall Fuel Drain Bolt to Fuel tank and tighten firmly using 3/4” socket or adjustable wrench. (For Models 3VE50H, 3VE51H, 3VE52I only. See Figure 12)

6. Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.

7. Store the heater in the original box with the original packing material and keep the USER’S MANUAL with the heater.

- Make sure storage place is free of dust and corrosive fumes.

- Store the heater in the original box with the original packing material and keep USER’S MANUAL with heater.

8

MaintenanceNever service heaterwhile it is plugged in

or while hot!

USE ORIGINAL EQUIPMENT REPLACE -MENT PARTS. Use of third-party orother alternate components will voidwarranty and may cause unsafeoperating conditions.

FUEL TANK

Flush every 200 hours of operation or asneeded (See Long-term Storage, page 7).

AIR INTAKE FILTER

WASH AND DRY WITH SOAP ANDWATER EVERY 500 HOURS OFOPERATION, OR AS NEEDED.

- Remove screws along each side ofheater using medium Phillipsscrewdriver.

- Lift off upper shell.

- Remove fan guard.

- Wash or replace air intake filter.

- Reinstall fan guard and upper shell.

AIR OUTPUT FILTER, LINT FILTER

REPLACE EVERY 500 HOURS OFOPERATION OR ONCE A YEAR

- Remove upper shell and fan guard(See Air Intake Filter Figure 14).

- Turn air pressure gauge counter-clockwise and remove.

- Remove end filter cover screws usingmedium Phillips screwdriver.

- Remove end filter cover.- Replace air output and lint filter.- Reinstall end filter cover and air

pressure gauge.- Reinstall fan guard and upper shell.

FAN BLADES

CLEAN EVERY SEASON OR AS NEEDED

- Remove upper shell (See Air IntakeFilter).

- Use M6 Allen wrench to loosen setscrew which holds fan blade to motorshaft.

- Slip fan blade off motor shaft.- Clean fan blade using soft cloth

moistened with kerosene or solvent.- Dry fan blade thoroughly.- Reinstall fan blade to motor shaft.- Place fan blade hub flush with end of

motor shaft.

WARNING

Dayton Operating Instructions and Parts Manual

Dayton® Portable Oil-Fired Heaters

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Figure 13 – Air Filter Access

Figure 12 - Drain Bolt

Fuel Drain Bolt

Seal

Screw

Upper Shell

Air Intake Filter

Fan Guard

Air Output Filter

CoverEnd Filter

Air IntakeFilter

Screw

Air Pressure GaugeLint Filter

Figure 14 – Filter Assembly

ENGLISH

3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

Page 9: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

Maintenance (Continued)- Place set screw on flat of shaft.- Tighten screw firmly (40-50 inch-

pounds/4.5-5.6 N-m). Reinstall upper shell.

NOZZLE

CLEAN NOZZLE AS NEEDED SPARK PLUG

CLEAN AND REGAP EVERY 600 HOURSOF OPERATION OR REPLACE ASNEEDED.

9

For Technical Support or Troubleshooting, Call: 1-800-Grainger ®

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I Dayton Operating Instructions and Parts Manual

Figure 15 – Fan Assembly Figure 16 – Nozzle Replacement Figure 17 – Nozzle Replacement

ENGLISH(For Models 3VE48G, 3VE49G, 3VE50H

and 3VE51H only)- Remove upper shell (See Air Intake Filter, page 8).- Remove fan blade (See Fan Blades).- Remove fuel and air line hoses from nozzle adaptor.- Remove ignitor wire from spark plug. - Remove spark plug from nozzle adaptor using medium phillips screwdriver.- Turn nozzle adaptor 1/9 turn(40°) to counter clock wise and pull toward motor to remove. (See Figure 14)- Place plastic hex-body into vise and lightlry tighten.- Carefully remove nozzle from nozzle adaptor using 5/8” socket wrench.- Blow compressed air through face of nozzle. (this will remove any dirt in nozzle) - Reinstall nozzle into nozzle adaptor until nozzle seats. Tighten 1/3 turn more using 5/8” socket wrench. (40~45 inch-pounds)- Reinstall nozzle adaptor to bracket adaptor.- Reinstall spark plug to nozzle adaptor.- Attach ignitor wire to spark plug.- Attach fuel and air line hoses to nozzle adaptor.- Reinstall fan blade and upper shell.

(For Model 3VE52I only)- Remove upper shell (See Air Intake Filter, page 8).- Remove fan blade (See Fan Blades).- Remove fuel and air line hoses from nozzle adaptor.- Remove ignitor wire from spark plug.- Remove spark plug from nozzle adaptor using medium phillips screwdriver.- Turn nozzle adaptor 1/8 turn (45°) to counter clock wise and pull toward motor to remove. (See Figure 15)- Place plastic hex-body into vise and lightly tighten.- Carefully remove nozzle from nozzle adaptor using 5/8”socket wrench.- Blow compressed air through face of nozzle. (this will remove any dirt in nozzle)- Reinstall nozzle into nozzle adaptor until nozzle seats Tighten 1/3 turn more using 5/8” socket wrench (40~45 inch-pounds)

- Reinstall nozzle adaptor to burner bracket- Reinstall spark plug to nozzle adaptor.- Attach ignitor wire to spark plug.- Attach fuel and air line hoses to nozzle adaptor.- Reinstall fan blade and upper shell.

(For Models 3VE48G, 3VE49G, 3VE50Hand 3VE51H only)- Remove upper shell (See Air Intake Filter, page 8).- Remove fan (See Fan Blades).- Remove ignitor wire from spark plug.- Remove spark plug from nozzle adaptor using mediumphillips screwdriver.- Clean and regap spark plug electrodes to 3.5mm gap.(0.138”)

Set Screw

Motor Shaft

Fan Blade

Flush

Motor

Fuel Line

Air Line

Nozzle Adaptor

Combustion Chamber

ScrewIgnitor Wire

Spark Plug

Bracket-Burner

Nozzle Adaptor

Nozzle Face

Nozzle

Nozzle Adaptor

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Nozzle Adaptor

Bracket-Adaptor

Air Line

Fuel Line

Ignitor WireScrew

Nozzle Face

Nozzle Adaptor

Nozzle

Combustion Chamber

Page 10: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

Maintenance (Continued) PHOTOCELL

CLEAN PHOTOCELL ANNUALLY OR ASNEEDED.

FUEL FILTER

CLEAN OR REPLACE TWICE PERHEATING SEASON OR AS NEEDED.

10

Dayton Operating Instructions and Parts Manual

Dayton® Portable Oil-Fired Heaters

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Figure 18 – Spark Plug Replacement

Figure 19 – Spark Plug Replacement

Figure 20 – Photocell Replacement for 3VE48G

Figure 21 – Photocell Replacement for3VE49G, 3VE50H, 3VE51H,3VE52I

ENGLISH

- Reinstall spark plug to nozzle adaptor.- Attach ignitor wire to spark plug.- Reinstall fan and upper shell.

(For Model 3VE52I only)- Remove upper shell (See Air Intake Filter, page 8).- Remove fan (See Fan Blades).- Remove ignitor wire from nozzle adaptor.- Remove spark plug from nozzle adaptor using mediumphillips screwdriver.- Clean and regap spark plug electrodes to 3.5mm gap.(0.138”)- ReInstall spark plug to nozzle adaptor.- Attach ignitor wire to spark plug.- Reinstall fan and upper shell.

(For Model 3VE48G only)- Remove upper shell (See Air Intake Filter, page 8).- Remove fan (See Fan Blades).- Remove photocell from its mounting bracket.- Clean photocell lens with cotton swab.

TO REPLACE: Remove side cover near power switch.- Disconnect wires from circuit board and remove photocell.- Install new photocell and attach wires to circuit board.- Reinstall fan and upper shell.

(For Model 3VE49G, 3VE50H, 3VE51H and 3VE52I only)- Remove upper shell (See Air Intake Filter, page 8).- Remove fan (See Fan Blades).- Remove photocell from its mounting bracket.- Clean photocell lens with cotton swab.

TO REPLACE: Remove side cover near power switch.- Disconnect wires from power switch and remove side cover.- Disconnect wires from circuit board and remove photocell.- Install new photocell and attach wiresto circuit board.- Replace switch wires to power switchand side cover.- Replace fan and upper shell.

(For Models 3VE48G, 3VE49G only)- Remove side cover screws using medium Phillips screwdriver.- Disconnect switch wires from power switch (3VE49G only).

Photocell

Incorrect CorrectInstall Photocell

Lens

Switch

Photocell WireBracket

ScrewWiresSwitch

Side CoverPower

Nozzle Adaptor

Ignitor Wire

Spark PlugScrew

GA

P Spark Plug

Side Cover

Screw

CircuitBoard

WirePhotocell

3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52INEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Ignitor Wire

Spark PlugNozzle Adaptor

Spark Plug

GA

P

Screw

Page 11: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

11

®

Maintenance (Continued)- Remove side cover.

- Pull fuel line off fuel filter neck.

- Turn fuel filter counterclockwise 90 degrees, pull, and remove.

- Wash fuel filter with clean fuel andreplace in tank.

- Attach fuel line to fuel filter neck.

- Reinstall side cover.

(For Models 3VE50H, 3VE51H, 3VE52I only)- Remove side cover screws using

medium Phillips screwdriver.

- Disconnect switch wires from powerswitch and remove side cover.

- Pull fuel line off fuel filter neck.

- Turn fuel filter clockwise 90 degreesand pull to remove.

- Wash fuel filter with clean fuel andreplace in tank.

- Attach fuel line to fuel filter neck.

- Reinstall side cover.

PUMP PRESSURE ADJUSTMENT

- Start heater (See “Operation”, page 7).

- Allow motor to reach full speed.

- Adjust pressure (using flat bladescrewdriver).

- Turn relief valve clockwise to increasepressure.

- Turn relief valve counterclockwise todecrease pressure.

- Set pump pressure to correct pressurefor each model.

- Stop heater (see “Operation”, page 7).

NOTE: USE ONLY ORIGINALEQUIPMENT REPLACEMENT PARTS. Useof alternate or third party componentswill void warranty and may cause anunsafe operating condition.

Dayton Operating Instructions and Parts Manual

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Figure 22 – Fuel Filter Replacement

Figure 23 – Fuel Filter Replacement

Figure 24 – Adjusting Pump Pressure

Model Pump Pressure

3VE48G 3.8 PSI

3VE49G 3.8 PSI

3VE50H 5.5 PSI

3VE51H 6.5 PSI

3VE52I 8.5 PSI

Fuel Filter

Fuel Line

Switch Wires

Power Switch

Side CoverScrew

ENGLISH

Fuel FilterFuel Line

Switch Wires

Side Cover

Power Switch

Screw

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

Flat bladeScrewdriver

Pressure Gauge

Relief Valve

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Page 12: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

Screw

Side Cover

Power SwitchSwitch Wire

12

Maintenance (Continued)REPLACING FUSE

NOTE: The heater is fuse protected. Ifyour heater fails to ignite, DO NOTRETURN YOUR HEATER TO THE STORE.

Please follow the simple instructionsbelow to inspect and change the fuse.

SHOCK HAZARD. Toprevent personal

injury, unplug the power cord beforereplacing fuse.

- Unplug heater.

- Remove side cover screws usingmedium Phillips screwdriver.

- Disconnect switch wires from powerswitch (3VE49G, 3VE50H, 3VE51H and3VE52I Models Only) .

- Remove fuse from fuse holder (SeeFigure 25).

- Replace fuse. FIRE HAZARD. Toavoid fire, Do not

substitute with a higher or lowercurrent rating.

- Replace switch wires to power switch(3VE49G, 3VE50H, 3VE51H and 3VE52IModels Only).

- Replace side cover.

NOTE: Specified fuse rating: AC 125/8A

WARNING

WARNING

Dayton Operating Instructions and Parts Manual

Dayton® Portable Oil-Fired Heaters3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Figure 25 – Replacing Fuse

Models: 3VE49G, 3VE50H, 3VE51Hand 3VE52I

Model 3VE48G

Fuse Holder

Fuse

ENGLISH

Fuse HolderFuse

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Page 13: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

13

®

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I Dayton Operating Instructions and Parts Manual

Wiring Diagrams

Figure 26 – Wiring Diagram Model 3VE48G

Figure 27 – Wiring Diagram Models 3VE49G, 3VE50H, 3VE51H and 3VE52I

For Technical Support or Troubleshooting, Call: 1-800-Grainger

ENGLISH

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

MODEL CAPACITOR

3VE49G

3VE50H 20uF/350VAC

15uF/230VAC

20uF/350VAC

20uF/350VAC

3VE51H

3VE52I

Wiring Diagrams

CN7

RED

CONTROLSWITCH

EARTH

GREEN60Hz

BLACKPLUG

AC120V

8A/125VAC

WHITE

BLACK

ORANGE

POWER

BLACK

POWER

BLACKPHOTO CELL

LIMIT FUSE

BLAC

K

PW-W/H

PW-BLK

RED

CN2

2P(LED)CN1 CN1

POWER LAMP CN3 RED

DISPLAY PCB CONTROL PCB

WH

ITE

15uF/230VACEARTH

GREEN

MOTOR WHITECAPACITOR

IGNITOR

BLACK

BLACK

BLACK

PUMP

SPARK PLUG

CN3

RED

RED

SWITCH CONTROLBLACK

GREEN

EARTH

60Hz

PLUG 8A/125VACBLACK

WHITE

SPARK PLUG

(TEMP. CONTROL)

BLACK

BLACK

THERMOSTAT

CELLPHOTO

POWER FUSE

SENSORROOM

POWER LIMIT

BLAC

K

WH

ITE

CN2(AC2)/

CN1(AC1)/CN6CN5

WHT

BLKEARTH

GREENCAPACITOR

RED WHITEMOTOR

POWER LAMP(LED)

IGNITOR

ORANGE

CN4

BLACK

BLACK

PUMP

BLACK

CONTROL PCB

AC120V

Page 14: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

1234567891011121314151617

Fuel Tank AssmeblyFuel Drain-BoltFuel GaugeFuel Filter AssmblyCord BushingPower CordButton SupportDisplay P.C.B AssemblyShell LowerFlange ScrewBushing-Grommet(S)Bushing-Grommet(L)Air-LineTemperature Limit AssemblyFlange-ScrewChamber AssemblyBracket Photocell

2151-0046-01-2156-0046-002155-0005-003712-0013-003980-0274-003713-0048-00215A-0013-003111-0501-014319-0015-003231-0120-003231-0121-003341-0035-002153-0022-004319-0015-002152-0234-003131-0159-00

2151-0047-01-2156-0049-002155-0005-003712-0013-003980-0274-00--3111-0501-014319-0015-003231-0120-003231-0121-003341-0035-002153-0022-004319-0015-002152-0236-003131-0159-00

2151-0048-014329-0072-002156-0050-002155-0001-003712-0013-003980-0275-00--3111-0506-014319-0015-003231-0120-003231-0121-003341-0036-002153-0023-004319-0015-002152-0238-003131-0159-00

2151-0049-014329-0072-002156-0051-002155-0001-003712-0013-003980-0275-00--3111-0508-014319-0015-003231-0120-003231-0121-003341-0038-002153-0023-004319-0015-002152-0240-003131-0159-00

11111121141211111

:sledoM rof rebmuN traPecnerefeRNumber Description 3VE48G 3VE49G 3VE50H 3VE51H Quantity

Repair Parts List for Portable Oil-Fired Heaters

14

Dayton Operating Instructions and Parts Manual 3VE48G, 3VE49G, 3VE50H, 3VE51H

For Technical Support or Troubleshooting, Call: 1-800-Grainger

Figure 28 – Repair Parts Illustration for Portable Oil-Fired Heaters Models 3VE48G, 3VE49G, 3VE50H and 3VE51H

For Repair Parts, call 1-800-Grainger24 hours a day – 365 days a yearPlease provide following information:-Model number-Serial number (if any)-Part description and number as shown in parts list

ENGLISH

212040

28

25

22-822-7

22-1

2322

1913

34

8

7

39

42

38

41

1827

26

15

17

9

16

10

15

1112

24

3631

37

1

4

3

30

29

6

5

35

233

32

14

25-1725-4

25-1425-13

25-1225-10

25-1625-15

25-11

25-7

25-525-2

25-6

25-125-3

25-825-9

25-18

25-1925-20

25-21

22-2

22-4

22-322-5

22-6

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

19Screw-BH1Photocell Assembly

4311-0068-00SP-KFA1007

4311-0068-00SP-KFA1007

4311-0068-00SP-KFA1007

4311-0068-00SP-KFA1007

21

18

Page 15: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

15

For Technical Support or Troubleshooting, Call: 1-800-Grainger ®

(*) Parts included in tune-up kit.

Models 3VE48G, 3VE49G, 3VE50H and 3VE51HDayton Operating Instructions and Parts Manual

ENGLISH

212222-122-222-322-422-522-622-722-8

2423

2525-125-225-325-425-525-625-725-825-925-1025-1125-1225-1325-1425-1525-1625-1725-1825-1925-2025-21

2726

282930313233343536373839404142

Air DeflectorFlange ScrewBurner Head AssemblyBracket AdaptorNozzle*Washer-Nozzle SealSpring-Nozzle SealO-RingNozzle AdaptorSpark Plug*Bolt-FlangeFlange ScrewFuel LineMotor and Pump AssemblyMotorCapacitorMotor SupportNut-HexHolder CapacitorPump BodyBolt-BH SpecialRotor*Blade*Insert*End Pump CoverElbowLint Filter*Bolt FlangeOutput Filter*End Filter CoverBallSpringAdjusting ScrewBolt FlangeIntake Filter*Fan AssemblyBolt Headless Hex SocketPressure GaugeMain P.C.B AssemblyScrew-TH2SIgnitorSide Cover-RightPower SwitchWindow DisplayFlange ScrewSide Cover-LeftFlange ScrewShell UpperClip NutFan GuardFlange ScrewFront GuardTune Up Kit

3131-0574-004319-0015-002152-0232-003131-0576-00SP-KFA10264349-0016-003431-0010-003311-0002-003231-0239-00SP-KFA10214329-0079-004319-0015-003341-0034-002154-0135-003970-0210-003820-0257-003111-0440-004331-0022-00-3541-0022-004321-0198-00See SP-KFA10001

See SP-KFA10001

See SP-KFA10001

3531-0027-003231-0181-00See SP-KFA10052

4329-0016-00See SP-KFA10052

3221-0029-00See SP-KFA10063

See SP-KFA10063

See SP-KFA10063

4329-0016-00See SP-KFA10052

2154-0009-004323-0004-003740-0049-00215A-0048-004312-0046-0039E0-0071-003121-0496-1539A0-0191-00-4319-0015-003121-0190-004319-0015-003111-0502-013131-0182-003221-0074-004319-0015-003561-0066-0021EX25

3131-0574-004319-0015-002152-0228-003131-0576-00SP-KFA10274349-0016-003431-0010-003311-0002-003231-0239-00SP-KFA10214329-0079-004319-0015-003341-0034-002154-0135-003970-0210-003820-0257-003111-0440-004331-0022-00-3541-0022-004321-0198-00See SP-KFA10001

See SP-KFA10001

See SP-KFA10001

3531-0027-003231-0181-00See SP-KFA10052

4329-0016-00See SP-KFA10052

3221-0029-00See SP-KFA10063

See SP-KFA10063

See SP-KFA10063

4329-0016-00See SP-KFA10052

2154-0009-004323-0004-003740-0049-00215A-0073-004312-0046-0039E0-0071-003121-0497-2939A0-0191-00-4319-0015-003121-0350-004319-0015-003111-0502-013131-0182-003221-0074-004319-0015-003561-0066-0021EX26

3131-0575-004319-0015-002152-0193-003131-0576-00SP-KFA10034349-0016-003431-0010-003311-0002-003231-0180-00SP-KFA10214329-0079-004319-0015-003341-0032-002154-0136-003970-0211-003820-0258-003111-0439-004331-0022-003231-0182-003541-0022-004321-0198-00See SP-KFA10001

See SP-KFA10001

See SP-KFA10001

3531-0027-003231-0181-00See SP-KFA10052

4329-0016-00See SP-KFA10052

3221-0029-00See SP-KFA10063

See SP-KFA10063

See SP-KFA10063

4329-0016-00See SP-KFA10052

2154-0004-004323-0004-003740-0049-00215A-0074-004312-0046-0039E0-0071-003121-0498-2039A0-0191-003231-0113-004319-0015-003121-0504-004319-0015-003111-0507-01-3221-0075-004319-0015-00-21EX27

3131-0575-004319-0015-002152-0194-003131-0576-00SP-KFA10044349-0016-003431-0010-003311-0002-003231-0180-00SP-KFA10214329-0079-004319-0015-003341-0032-002154-0138-003970-0212-003820-0258-003111-0439-004331-0022-003231-0182-003541-0022-004321-0198-00See SP-KFA10001

See SP-KFA10001

See SP-KFA10001

3531-0027-003231-0181-00See SP-KFA10052

4329-0081-00See SP-KFA10052

3221-0029-00See SP-KFA10063

See SP-KFA10063

See SP-KFA10063

4329-0016-00See SP-KFA10052

2154-0007-004323-0004-003740-0049-00215A-0074-004312-0046-0039E0-0071-003121-0499-3939A0-0191-003231-0113-004319-0015-003121-0506-004319-0015-003111-0509-01

3221-0075-004319-0015-00-21EX28

2211121111131111121121411116111114111112111141412181

:sledoM rof rebmuN traPecnerefeRNumber Description 3VE48G 3VE49G 3VE50H 3VE51H Quantity

Repair Parts List for Portable Oil-Fired Heaters (Continued)

123

Rotor kitFilter kitPlug/Pump adjuster kit

SP-KFA1000SP-KFA1005SP-KFA1006

SP-KFA1000SP-KFA1005SP-KFA1006

SP-KFA1000SP-KFA1005SP-KFA1006

SP-KFA1000SP-KFA1005SP-KFA1006

111

:sledoM rof rebmuN traPecnerefeRNumber Description Quantity

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

20

3VE48G 3VE49G 3VE50H 3VE51H

Page 16: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

21

35

1716

1120

6

18-818-7

18-6

18-5

18-4

18-3

18-2

18-1

34

36

1819

2223

13

15

7

14

24

8

11

9

1022

3227

33

1

4

3

26

25

5

31

229

2830

12

21-1721-4

21-1421-13

21-12

21-10

21-1621-15

21-11

21-7

21-5

21-2

21-6

21-1

21-3

21-821-9

21-18

21-19

21-20

21-21

16

Dayton Operating Instructions and Parts Manual 3VE52I

Figure 29 – Repair Parts Illustration for Portable Oil-Fired Heater (Model 3VE52I)

For Technical Support or Troubleshooting, Call: 1-800-Grainger

For Repair Parts, call 1-800-Grainger24 hours a day – 365 days a yearPlease provide following information:-Model number-Serial number (if any)-Part description and number as shown in parts list

ENGLISH

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Page 17: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

17

®

Model 3VE52IDayton Operating Instructions and Parts Manual

Repair Parts List for Portable Oil-Fir

123456789101112131415161718

1920

18-118-218-318-418-518-618-718-8

22

21

23

21-121-221-321-4

21-521-621-721-821-921-1021-1121-1221-1321-1421-1521-1621-1721-1821-1921-2021-21

2524

2627282930313233343536

traP.feRNo. Description No. Qty.

traP.feRNo. Description No. Qty.

(*) Parts included in tune-up kit.

For Technical Support or Troubleshooting, Call: 1-800-Grainger

ENGLISH

Fuel Tank AssmeblyFuel Drain-BoltFuel GaugeFuel Filter AssmblyFuel CapPower CordShell LowerFlange ScrewBushing-Grommet(S)Bushing-Grommet(L)Air-LineTemperature Limit AssemblyFlange-ScrewChamber AssemblyBracket PhotocellScrew-BH1Photocell AssemblyBurner Head AssemblyBracket BurnerNozzle*Washer-Nozzle SealSpring-Nozzle SealO-RingNozzle AdaptorSpark Plug*Bolt-FlangeFlange ScrewFuel LineMotor and Pump AssemblyMotorCapacitorSupportor MotorNut-Hex

2151-0049-014329-0072-002156-0052-002155-0001-002151-0041-003980-0275-003111-0504-014319-0015-003231-0120-003231-0121-003341-0036-002153-0024-004319-0015-002152-0050-003131-0159-004311-0068-00SP-KFA10072152-0124-003121-0477-00SP-KFA10114349-0016-003431-0010-003311-0002-003231-0180-00SP-KFA10214329-0079-004319-0015-003341-0039-002154-0139-003970-0213-003820-0258-003111-0439-004331-0022-00

111111141211111211111111114111112

123

traP.feRNo. Description No. Qty.

Rotor kitFilter kitPlug/Pump adjuster kit

SP-KFA1022SP-KFA1005SP-KFA1006

111

Holder CapacitorPump BodyBolt-BH SpecialRotor*Blade*Insert*End Pump CoverElbowLint Filter*Bolt FlangeOutput Filter*End Filter CoverBallSpringAdjusting ScrewBolt FlangeIntake Filter*Fan AssemblyBolt Headless Hex SocketPressure GaugeMain P.C.B AssemblyScrew-TH2SIgnitorSide Cover-RightPower SwitchWindow DisplayFlange ScrewSide Cover-LeftFlange ScrewShell UpperFan GuardFlange ScrewTune Up Kit

3231-0182-003541-0050-004321-0198-00See SP-KFA10221

See SP-KFA10221

See SP-KFA10221

3531-0027-003231-0181-00See SP-KFA10052

4329-0016-00See SP-KFA10052

3221-0029-00See SP-KFA10063

See SP-KFA10063

See SP-KFA10063

4329-0016-00See SP-KFA10052

2154-0007-004323-0004-003740-0049-00215A-0074-004312-0046-0039E0-0071-003121-0499-4239A0-0191-003231-0113-004319-0015-003121-0506-004319-0015-003111-0505-013221-0075-004319-0015-0021EX29

11214111161111141111121111414118

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

ed Heater (Model 3VE52I)

Page 18: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

18

For Technical Support or Troubleshooting, Call: 1-800-Grainger

ENGLISH

Dayton Operating Instructions and Parts Manual

For Repair Parts, call 1-800-Grainger24 hours a day – 365 days a yearPlease provide following information:-Model number-Serial number (if any)-Part description and number as shown in parts list

3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I

:sledoM rof .oN traP.feRNo. Description 3VE50H 3VE51H/3VE52I Qty.

Front HandleRear HandleWheel Support FrameWheelThreaded AxleCord WrapHardware KitScrew Flange ScrewCap Nut SNutBushingCap Nut L

3551-0104-003551-0105-003551-0111-003720-0017-003551-0088-003221-0088-00HW-KFA1021

INCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KIT

3551-0112-003551-0113-003551-0114-003720-0017-003551-0089-003221-0088-00HW-KFA1021

IINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KITINCLUDED IN HARDWARE KIT

1112121844822

12345677-17-27-37-47-57-6

Figure 30 – Repair Parts Illustration forModels 3VE48G, 3VE49G

1 Handle 3231-0073-00 12 Cord Wrap 3221-0041-00 2

traP.feRNo. Description No. Qty.

Replacement Parts List for Models 3VE48G, 3VE49G

Figure 31 – Repair Parts Illustration for Models3VE50H, 3VE51H, 3VE52I

Replacement Parts List for Models 3VE50H, 3VE51H,3VE52I

2

1

5

7-2

2

1

3

4

6

7-1

7-3

7-4

7-5

7-6

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Page 19: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

19

Models 3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52I Dayton Operating Instructions and Parts Manual

For Technical Support or Troubleshooting, Call: 1-800-Grainger

noitcA evitcerroC)s(esuaC elbissoPmotpmyS

Heater ignites but MAIN PCBassembly shuts heater offafter a short period of time.(Indicator Lamp is flickeringand room temp. displayindicates “E1”)

Heater will not ignite butmotor runs for a short periodof time. (Indicator Lamp isflickering and room temp.display indicates “E1”)

Fan does not turn whenheater is plugged in andpower switch was in the “ON”position. (Indicator Lamp is onor flickering)

(Indicator Lamp is flickeringand room temp. displayindicates “E2”)

(Indicator Lamp is flickeringand room temp. displayindicates “E3”)

Heater will not turn-on(Indicator Lamp is off)

1. Wrong pump pressure

2. Dirty Air Output, Air Intake or Lint Filter

3. Dirty Fuel Filter

4. Dirt in Nozzle

5. Dirt Photocell Lens

6. Photocell Assembly not Properly Installed(not seeing the flame)

7. Bad electrical connection between photocelland MAIN PCB Assembly

8. Defective photocell

1. No fuel in tank

2. Wrong pump pressure

3. Carbon deposits on spark plug and/orimproper gap

4. Dirty fuel filter

5. Dirt in Nozzle

6. Water in fuel tank

7. Bad electrical connection between igniterand MAIN PCB Assembly

8. Igniter wire is not attached to spark plug

1. Thermostat setting is too low

2. Bad electrical connection between motor andMAIN PCB Assembly

1. Sensor Failure

1. Thermostat switch failure

1. Temperature limit safety device is overheated

2. No electrical power

3. Blown fuse

4. Bad electrical connection betweentemperature limit safety device and PCB board

1. See Pump Pressure Adjustment, page 11

2. See Air Output, Air Intake and Lint Filters,page 8

3. See Fuel Filter, page 11

4. See Nozzle, page 9

5. Clean Photocell Lens, page 10

6. Make sure photocell boot is properly seated inbracket, Page 10

7. Check electrical components. See WiringDiagrams, page 13

8. Replace Photocell, page 10

1. Fill tank with kerosene

2. See Pump Pressure Adjustment, page 11

3. See Spark Plug, page 9

4. See Fuel Filter, page 11

5. See Nozzle, page 9

6. Flush fuel tank with clean kerosene, page 7

7. Check electrical components. See WiringDiagram, page 13

8. Attach igniter to spark plug. See Spark Plug,page 9

1. Turn thermostat control knob to a highersetting

2. Check electrical connections. See WiringDiagram, page 13

1. Replace sensor. See Wiring Diagram,page 13

1. Replace switch. See Wiring Diagram,page 13

1. Turn power switch to “OFF” and allow to cool(about 10 min.)

2. Check to insure heater cord and extensioncord are plugged in. Check power supply

3. Replace safety fuse in PCB board. SeeReplacing Fuse, page 12

4. Check electrical connections. See WiringDiagrams, page 13

Troubleshooting Chart

ENGLISH

®

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Page 20: Dayton Portable Oil-Fired Heaters - GHP Group, Inc.EN...dealer where you purchased heater. Dayton ® Portable Oil-Fired Heaters Operating Instructions & Parts Manual 3VE48G, 3VE49G,

ENGLISH

Dayton® Portable Oil-Fired HeatersDayton Operating Instructions and Parts Manual

LIMITED WARRANTY

DAYTON ONE-YEAR LIMITED WARRANTY. DAYTON® PORTABLE OIL-FIRED HEATERS, MODELS COVERED IN THIS MANUAL,ARE WARRANTED BY DAYTON ELECTRIC MFG. CO. (DAYTON) TO THE ORIGINAL USER AGAINST DEFECTS IN WORKMANSHIPOR MATERIALS UNDER NORMAL USE FOR ONE YEAR AFTER DATE OF PURCHASE. ANY PART WHICH IS DETERMINED TO BEDEFECTIVE IN MATERIAL OR WORKMANSHIP AND RETURNED TO AN AUTHORIZED SERVICE LOCATION, AS DAYTONDESIGNATES, SHIPPING COSTS PREPAID, WILL BE, AS THE EXCLUSIVE REMEDY, REPAIRED OR REPLACED AT DAYTON’SOPTION. FOR LIMITED WARRANTY CLAIM PROCEDURES, SEE “PROMPT DISPOSITION” BELOW. THIS LIMITED WARRANTYGIVES PURCHASERS SPECIFIC LEGAL RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION.

LIMITATION OF LIABILITY. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, DAYTON’S LIABILITY FOR CONSEQUENTIALAND INCIDENTAL DAMAGES IS EXPRESSLY DISCLAIMED. DAYTON’S LIABILITY IN ALL EVENTS IS LIMITED TO AND SHALL NOTEXCEED THE PURCHASE PRICE PAID.

WARRANTY DISCLAIMER. A DILIGENT EFFORT HAS BEEN MADE TO PROVIDE PRODUCT INFORMATION AND ILLUSTRATETHE PRODUCTS IN THIS LITERATURE ACCURATELY; HOWEVER, SUCH INFORMATION AND ILLUSTRATIONS ARE FOR THE SOLEPURPOSE OF IDENTIFICATION, AND DO NOT EXPRESS OR IMPLY A WARRANTY THAT THE PRODUCTS ARE MERCHANTABLE,OR FIT FOR A PARTICULAR PURPOSE, OR THAT THE PRODUCTS WILL NECESSARILY CONFORM TO THE ILLUSTRATIONS ORDESCRIPTIONS. EXCEPT AS PROVIDED BELOW, NO WARRANTY OR AFFIRMATION OF FACT, EXPRESSED OR IMPLIED, OTHERTHAN AS STATED IN THE “LIMITED WARRANTY” ABOVE IS MADE OR AUTHORIZED BY DAYTON.

Technical Advice and Recommendations, Disclaimer. Notwithstanding any past practice or dealings or trade custom,sales shall not include the furnishing of technical advice or assistance or system design. Dayton assumes no obligations orliability on account of any unauthorized recommendations, opinions or advice as to the choice, installation or use ofproducts.

Product Suitability. Many jurisdictions have codes and regulations governing sales, construction, installation, and/or use ofproducts for certain purposes, which may vary from those in neighboring areas. While attempts are made to assure thatDayton products comply with such codes, Dayton cannot guarantee compliance, and cannot be responsible for how theproduct is installed or used. Before purchase and use of a product, review the product applications, and all applicablenational and local codes and regulations, and be sure that the product, installation, and use will comply with them.

Certain aspects of disclaimers are not applicable to consumer products; e.g., (a) some jurisdictions do not allow the exclusionor limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you; (b) also,some jurisdictions do not allow a limitation on how long an implied warranty lasts, consequently the above limitation maynot apply to you; and (c) by law, during the period of this Limited Warranty, any implied warranties of impliedmerchantability or fitness for a particular purpose applicable to consumer products purchased by consumers, may not beexcluded or otherwise disclaimed.

Prompt Disposition. A good faith effort will be made for prompt correction or other adjustment with respect to anyproduct which proves to be defective within limited warranty. For any product believed to be defective within limitedwarranty, first write or call dealer from whom the product was purchased. Dealer will give additional directions. If unable toresolve satisfactorily, write to Dayton at address below, giving dealer’s name, address, date, and number of dealer’s invoice,and describing the nature of the defect. Title and risk of loss pass to buyer on delivery to common carrier. If product wasdamaged in transit to you, file claim with carrier.

Manufactured for Dayton Electric Mfg. Co.100 Grainger PKWY.Lake Forest, Illinois 60045 U.S.A.

®

3VE48G, 3VE49G, 3VE50H, 3VE51H and 3VE52INEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!