Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
1
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
2
Size 8 cavity CA08A3C (3/4-16UNF2A)
Size 20 cavity CA203C3 (1’-5/8-12UN2A)
Preferred cavity UNFCavity is “FACTORY”
Size 78: max flow 40lpm, max. pressure setting 350bar
Size 42: max flow 350lpm, max pressure setting 410bar
320lpm
420bar
30lpm
350bar
DC_DK Tech Day October 24th
Full range of counterbalance valve in PIB (Parts in Body) style Full range of counterbalance valve in Cartridge style
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
3
VBSO-SE-30 Parts in BodyVBSN Mechanical Cartridge
UNF cavity
SUN cavity Line mounted
Flangeable
PARTS-IN-BODY SOLUTIONS
READY TO BE INSTALLED
COST EFFECTIVE
MAXIMUM FLEXIBILITY
MACHINE FINE TUNING
HIGH PERFORMANCE
CARTRIDGE SOLUTIONS
CAVITY NEEDED
EASY TO INSTALL AND SERVICE
STANDARD PERFORMANCE
One hydraulic symbol but many solution. Which the best for customer’s application?
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
4
Counterbalance Valves, DIFFERENTIAL AREA
Standard: Cartridge VBSNPib VBSO
Relief CompensatedCartridge VBSPPib VBSO „CC“
Air Vented - 3 PortsCartridge VBSTPib VBSO „CCAP“
Tank Vented - 4 PortsCartridge VBSY Pib VBSO „CCAP”
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
6
TECHNICAL FEATURES: configurations – standard counterbalance
Open center Close center Tandem center
P load effected by back pressure
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
7
TECHNICAL FEATURES: configurations – standard counterbalance effect of back pressure
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
8
TECHNICAL FEATURES: configurations – relief compensated counterbalance
Relief function not effected by back pressure Pback
Close center Tandem center Open center
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
9
TECHNICAL FEATURES: configurations – relief compensated counterbalance
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
10
TECHNICAL FEATURES: configurations – fully compensated counterbalance
Close center Tandem center Open center
Setting and working pressure not effected by back pressure Pback Dangerous
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
11
TECHNICAL FEATURES: configurations – fully compensated counterbalance
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
13
Main application for PiB Load control
TCM:Boom, Arm, Extension
THL:Boom, Extension, Tilt
AWP:Boom, Arm, Extension, Jib, outriggers
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
14
Main application for Cartridge Hold load
Drilling:All cylinders thathold the Mast
Sweeper:Hold Tank
BHL:Front loader cylinder
Paver:Hopper cylinder
DC_DK Tech Day October 24th
Internal | DC-CH/SAL12 | 29/06/2018© Bosch Rexroth Oil Control S.p.A. 2018. All rights reserved.
15
Tank you