3
1 2 3 4 5 6 7 Feature 20000 IP66 IEC60947-3 4P 32A 1000V DC 32A 1000V DC 8KV -5℃~+852000 BYH-32 BYH-32 1 2 4 5 6 3 Ue In Ui Uimp Application Parameter Appearance Introduction BYH Series DC Isolator Switch in plastic enclosure is applied 1~20KW Residential or Commercial Photovoltaic system, placed between photovoltage modules and inverters. Arcing time less than 3ms, that keep solar system more safe. To ensure its stability and long service life, our products are made by components with optimum quality. Max voltage up to 1000V DC It holds a safe lead among similar products. BYH DC Isolator Switches Series IP66 , UV Resistance Arcing Time < 3ms Earth Terminal IEC/EN60947-3 2 Pole, 4 Poles Available(Single | Double String) DC-21B: 16A,25A,32A up to 1000VDC Waterproof Plug IP66 Ingress Protection Sealed Plug Knob Brand ON OFF Comply with Electrical Characteristics Function Pole Max Rated Current Rated Working Voltage Rated Current Rated Insulated Voltage Rated Impulsed Voltage Service Life/Cycle Operation Mechanical Electrical Installation Environment Ingress Protection Storage Temperature Type Isolator, Control Accessories 7

DC Isolator Switches - Sol Distribution Beny/Datasheet/BYH-32 V.1.1.pdf · BYH Series DC Isolator Switch in plastic enclosure is applied 1~20KW Residential or Commercial Photovoltaic

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

1

2

3

4

5

6

7

Feature

20000

IP66

IEC60947-3

4P

32A

1000V DC

32A

1000V DC

8KV

-5℃~+85℃

2000

BYH-32

BYH-32

1

2

4

5

6

3

Ue

In

Ui

Uimp

Application

Parameter

Appearance Introduction

BYH Series DC Isolator Switch in plast ic enclosure is

applied 1~20KW Residential or Commercial Photovoltaic system, placed between

photovoltage modules and inverters. Arcing time less than 3ms, that keep solar

system more safe. To ensure its stability and long service life, our products are

made by components with optimum quality. Max voltage up to 1000V DC It holds a

safe lead among similar products.

BYHDC Isolator Switches

Series

IP66 , UV Resistance

Arcing Time < 3ms

Earth Terminal

IEC/EN60947-3

2 Pole, 4 Poles Available(Single | Double String)

DC-21B: 16A,25A,32A up to 1000VDC

Waterproof Plug

IP66 Ingress Protection

Sealed Plug

Knob

Brand

ON

OFF

Comply with

Electrical Characteristics

Function

Pole

Max Rated Current

Rated Working Voltage

Rated Current

Rated Insulated Voltage

Rated Impulsed Voltage

Service Life/Cycle Operation

Mechanical

Electrical

Installation Environment

Ingress Protection

Storage Temperature

Type

Isolator, Control

Accessories

7

500V 600V 800V 1000V

32A 13A 2 1

50A 13A 2 1

2 2H 4 4S 4B 4T

32A 13A 2 2

32A 32A 4 1

32A 32A 4 1

32A 32A 4 1

32A

50A

32A

32A

32A

32A

23A

23A

23A

32A

32A

32A

1 3

2 4

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4 6 8

1 3 5 7

2 4

1 3

0.70

0.70

0.70

0.70

0.70

0.70

BYH-32PE2H

BYH-32PE4

BYH-32PE4S

BYH-32PE4B

BYH-32PE4T

BYH-32PE2

BYH-32

BYHPV DC Isolator Switches

Dimensions(mm)

Switching Configurations

Wiring Diagram

Contacts wiring diagram

Poles in series

Number of Strings

Type Number Weight kg/PCS

Contacts

Wiring graph

Switching

example

2-pole4-pole with Input

on top

Output bottom4 Paralleled

Poles

2-pole4-poleType

4-pole with Input

and

Output bottom

4-pole with Input

and

Output on top

Series

M25X1.547.0

78

.5 10

8.5

Ø4.3

10

0.0

17

8.5

75.0

99.0

17

0.5

18

8.0

Non-polarity DC Isolator SwitchBYH-32 Technical Data

DC-PV2Data according to IEC 60947-3 DC-PV2 AS5033:2014

Main Contacts Type BYH-32 Appendix B5Rated thermal current Ithe A 32 Making &Rated insulation voltage Ui V 1000 BreakingDistance of contacts (per pole) mm 8 5x

operationsRated operational current Ie 300V A 25 40.5DC21A 1 pole 400V A 16 24& DC21B 1 500V A 13 19.5

600V A 10 15800V A 5 7.5

L/R = 1ms 1000V A 2.5 3.75

DC21B 2 poles in series 500V A 32 482 600V A 32 48

700V A 27 40.5800V A 23 34.5900V A 20 30

1000V A 13 19.5

2 poles in series 500V A 58 87+ 2 poles parallel 600V A 50 752+2 700V A 27 40.5

800V A 23 34.5900V A 20 30

1000V A 13 19.5

3 poles in series 500V A 32 483 600V A 32 48

700V A 32 48800V A 32 48900V A 32 48

BYH-32 with IP66NW Enclosure 1000V A 32 48

3 poles in series 500V A 58 87+ 2 poles parallel 600V A 50 753+2 700V A 45 67.5

800V A 45 67.5900V A 45 67.5

1000V A 45 67.5

4 poles in series 500V A 32 484 600V A 32 48

700V A 32 48800V A 32 48900V A 32 48

1000V A 32 48

4 poles in series 500V A 58 87+ 2 poles parallel 600V A 58 874+2 700V A 58 87

800V A 58 87900V A 58 87