vanairsystems.com
Deliquescent Desiccants
Van Air Systems is the original and leading manufacturer of tableted deliquescent desiccants for drying compressed air and natural gas.
FE
AT
UR
ES
Energy Free
Dependable
Prevent Condensation
Low Maintenance
Inlet Temperature(saturated)
100°F90°F80°F70°F60°F50°F
OutletDew Point
80°F70°F60°F51°F42°F32°F
Dew PointSuppression
20°F20°F20°F19°F18°F18°F
Dew Point Performance
DRY-O-LITE® is the industry-leading, deliquescent desiccant. It’s a chemical drying agent specifi-cally formulated for Van Air Systems Single Tower Deliquescent Dryers and Natural Gas Pipeline Dryers (PLD Series).
DRY-O-LITE®/ GasDry™ Prime
White tablet3/4” diam x 5/8” height
72+ 3 lbs/ft3
60-100 lbs.
Color and formSizeBulk densityCrush Strength
Physical ProperitesFEATURES & BENEFITS• Low cost• Energy Free• Environmentally safe• Up to 20°F Dew Point Suppression• 55% Relative Humidity
Deliquescent DesiccantDeliquescent desiccants are a dependable, cost-effective, and energy-free tool for a wide range of drying applications.
Most Affordable Industry Leading Desiccant
SP / GasDry™ Peak is a chemical drying agent formulated primarily for the dehydration of natural gas. SP is recommended for the first stage of a multiple vessel drying system.
SP/GasDry™ Peak Peak Performance For Natural Gas Dehydration
White tablet1” diam x 3/4” height
55+ 3 lbs/ft3
60-100 lbs.
Color and formSizeBulk densityCrush Strength
Physical ProperitesFEATURES & BENEFITS• For operating temperatures 70°F and lower• Inhibits natural gas hydrate formation• Prevents gas line freeze-ups• Up to 27°F Dew Point Suppression• 33% Relative Humidity
Inlet Temperature(saturated)
70°F60°F55°F45°F
OutletDew Point
43°F36°F32°F25°F
Dew PointSuppression
27°F24°F23°F20°F
Dew Point PerformanceApplications:• High Pressure - Low Temperature Sales Gas• Fuel Gas & Biogas Dehydration• Pre Absorbing for higher grades of desiccant
With more than 65 years of experience developing desiccant formulas at its production facilities in Lake City, Pennsylvania, Van Air Systems is the original and leading manufacture of deliquescent desiccants for drying compressed air and gases. Deliquescent desiccants are a dependable, cost-effective, and energy-free tool for a wide range of drying applications.
What is Deliquescent desiccant? Deliquesce means to dissolve. A desiccant is a drying agent. So deliquescent desiccant is a drying agent that dissolves.
Choosing the right desiccant. With vapor attracting properties, deliquescent desiccants are ideal for drying compressed air and other gases and preventing the harmful effects of moisture. It’s important to choose the right grade of deliquescent desiccant. Van Air Systems offers four grades of deliquescent desiccant. Dry-O-Lite®, which is used for drying compressed air. Our other desiccants SP, 10BF. and 4UF are all typically selected for natural gas dehydration applications. Contact us for more information on which desiccant would be best for your application.
Applications:• Abrasive Blasting & Painting• Portable Air Drying• Ready-Mix & Concrete Plants• Wood Products• Fuel Gas• Low Pressure Gases
Inlet Temperature(saturated)
100°F90°F80°F70°F60°F50°F40°F
OutletDew Point
37°F30°F23°F16°F9°F2°F-5°F
Dew PointSuppression
63°F63°F57°F54°F51°F48°F45°F
Dew Point Performance
www.vanairsystems.com
Applications:• Meets Pipeline Gas Moisture Specifications• Fuel Gas & Biogas Dehydration• Instrument Gas Dehydration• Remote Outdoor Locations Without Electricity
10BF®/GasDry™ Max is the primary desiccant choice for Natural Gas applications. 10BF/Gas Dry Max has the highest moisture absorbing capacity per pound of any other deliquescent desiccant while still achieving very low moisture content.
10BF/GasDry™ Max
White tablet1” diam x 3/4” height
60+ 3 lbs/ft3
100-120 lbs.
Color and formSizeBulk densityCrush Strength
Physical ProperitesFEATURES & BENEFITS• For operating temperatures 100°F and lower• Replaces TEG systems• Prevents air and gas line freeze-ups• 45-63°F dewpoint suppression• 13% Equilibrium RH
Maximum Performance For Drying Compressed Air & Natural Gas
Natural gas or process gas dehydration at low pressures, low flow rates, and / or low temperatures can be very difficult. For these unique applications Gas DryTM Ultimate/4UF was developed to meet low dew point requirements when other desiccants or glycols are ineffective.
4UF/GasDry™ Ultimate Ultimate Dewpoint Suppression
White bullet shaped tablet3/8” diam x 1/2” height
80-85 lbs./cu. ft.
Color and formSizeBulk density
Physical ProperitesFEATURES & BENEFITS• 7 lbs H2O/MMSCF gas is attainable @ 50 psig & 60°F.• 20 lbs H2O/MMSCF gas is attainable @ 25 psig & 80°F.• Gas temperatures below freezing can be dried and still obtain a low equilibrium RH.• 4% Equilibrium RH• Can dry gas for a lower cost than glycol systems, in some applications.
Applications:• Meets Pipeline Gas Moisture Specifications• Fuel Gas & Biogas Dehydration • Instrument Gas Dehydration• Lowers moisture content of Biogas• Remote Outdoor Locations Without Electricity
How to use it?Gas DryTM Ultimate/4UF can be used by itself or in combination with other grades of deliquescent desiccant, such as Gas DryTM Peak/SP or Gas DryTM Max/10BF Desiccant. Consumption is reduced when the process gas flows through the lower grade desiccant prior to the highly absorbent Gas Dry Ultimate/4UF, resulting in lower operating cost.
Dense tablet, no dust. Deliquescent desiccants are environmentally safe and we guarantee performance!
Inlet Temperature(saturated)
100°F90°F80°F70°F60°F50°F40°F30°F
OutletDew Point
14°F8°F2°F-4°F-11°F-17°F-24°F-31°F
Dew PointSuppression
86°F82°F78°F74°F71°F67°F64°F61°F
Dew Point Performance
Please contact Van Air Systems’ Technical Applications
Department to determine the best desiccant for your application.
Dry-O-Lite® SP
2950 Mechanic Street, Lake City, PA 16423, USA | Toll Free Phone 800-840-9906 | Corporate Fax 814-774-0778 | Order Entry Fax 814-774-3482
Distributed By:
vanairsystems.com
Instructional Video
Deliquescent drying technology
Safety Data Sheet
10BF
Literature Downloads
Desiccant-VAS-6/2016
Download at www.vanairsystems.com
4UF
P a g e | 1
Section 1 – Product and Company Information Date: June 22, 2016 Rev. A Product Name: 4UF / Gas Dry ULTIMATE Chemical Desiccant Chemical Family: Mixture Catalog Numbers: 33-0416 Product Use: Industrial: Deliquescent desiccant to reduce moisture content
of Compressed Natural Gas, Compressed Air and other Compressed Gasses
Company Identification: Van Air Systems / Van Gas Technologies 2950 Mechanic Street, Lake City, PA USA 16423-2095
E-mail: [email protected] www.vanairsystems.com / www.vangastech.com Telephone: (814) 774-2631
Emergency Telephone Number call Chemtel: US, Canada, Puerto Rico 1-800-255-3924 (Van Air)
International +01-813-248-0585 (Van Air) Customer Service Telephone Number: 814-774-2631
Section 2 – Hazard Identification Color: White to gray-white Physical state: Solid bullet shaped tablet Odor: Odorless Classification of substance or mixture: GHS Classification [EC Regulation No 1272/2008 and US OSHA regulations] Acute Toxicity, Category 4 Serious Eye Damage, Category 1 Skin Corrosion Irritant, Category 2 Skin sensitizer, Category 1 Emergency Overview: Prevention: P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P264: Wash hands thoroughly after handling. P270: Do not eat, drink or smoke when using this product. P272: Contaminated work clothing should not be allowed out of the workplace. P280: Wear protective gloves/eye protection/face protection.
Response: P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor/ if you feel unwell. P330: Rinse mouth. P302+P352: IF ON SKIN: Wash with plenty of water. P333+P313: If skin irritation or rash occurs: Get medical advice/attention. P362+P364: Take off contaminated clothing and wash it before reuse. P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310: Immediately call a POISON CENTER/doctor.
Disposal: P501: Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
Other hazards which do not result in GHS classification: None Identified.
Safety Data Sheet 4UF
GAS DRY ULTIMATE Chemical Desiccant