14
DELL Force10 Interoperability Guide Interoperability Guide on Key Features Dell Force10 Force10 Marketing Team July 2012

Dell Force10 Interoperability Guide

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Dell Force10 Interoperability Guide

DELL Force10 Interoperability Guide

Interoperability Guide on Key Features

Dell │ Force10

Force10 Marketing Team

July 2012

Page 2: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page ii

THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS

OR IMPLIED WARRANTIES OF ANY KIND.

© 2010 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without

the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell.

Dell, the DELL logo, and the DELL badge, PowerConnect, and PowerVault are trademarks of Dell Inc. Symantec and the SYMANTEC logo are trademarks or registered trademarks of Symantec Corporation

or its affiliates in the US and other countries. Microsoft, Windows, Windows Server, and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States

and/or other countries. Other trademarks and trade names may be used in this document to refer to

either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary

interest in trademarks and trade names other than its own.

July 2012

Page 3: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 1

Contents Introduction ................................................................................................................ 2 Purpose of This Document ............................................................................................. 2 VTP........................................................................................................................... 3

Spanning Tree Protocols ................................................................................................ 4

PVST (FTOS) and PVST+ (IOS) ..................................................................................... 5

Switch Configuration ............................................................................................... 5

Convergence Test: .................................................................................................. 7

Results: ................................................................................................................ 7

RSTP and RPVST+ ................................................................................................... 8

Switch Configuration ............................................................................................... 8

Convergence Test: ................................................................................................ 10

Results: .............................................................................................................. 10

MSTP ................................................................................................................. 11

Implementation Note .................................................................................................. 11 Miscellaneous ...................................................................................................... 12

Port Channels ............................................................................................................ 12

Figures

Figure 1 : VTP Basic Test Setup .......................................................................... 3 Figure 2: Port Channel FTOS Screenshot .............................................................. 4 Figure 3 : Dell Force 10 and Cisco Catalyst 6509 PVST+ Test Setup .............................. 5 Figure 4 : RSTP and PVST+ Setup ................................... Error! Bookmark not defined. Figure 5 : S4810_1 Configuration ........................................................................ 8 Figure 6 : S4810_2 Configuration ....................................................................... 9 Figure 7 : Catalyst 6509 Configuration ................................................................. 9 Figure 8 : Port Channel Setup ........................................................................... 12 Figure 9 : Port Channel Configuration ................................................................. 12

Tables

Table 1 : Dell Force 10 vs. Cisco Features

Page 4: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 2

Introduction Vendors influence network architectures through features and functionality found in the equipment

they manufacture, leading to the overall look and feel of the network. For example, some vendor-

driven networks require a 3-tier model with core, distribution and access. Although this has been the

prevalent design in the past 10 years or so, the overall increase in capex and opex expenses due to the

number of switches at network layer has remained on par. Such design deserves another look.

The proprietary nature of the protocols and features locked customers to one particular vendor, with

some forced interdependencies of some features. Customers were forced to use proprietary features

by the vendor-created dependencies between protocols. For example, early Cisco IP phones rely on

CDP to collect network information and use a Cisco-proprietary PoE standard, not the IEEE standard.

The Dell Force10 philosophy always has bucked this approach. Instead, buy less and build best-of-

breed open and converged networks has been the model. Force10 allows for a 2-tier model of

core/distribution and access. Less equipment means lower capex and opex expenses as well as a

lower number of networking points of failure. Customers can design their networks with standards-

based protocols and features without the need to worry about whether features will be disabled /

unsupported. We have the confidence to allow our customers to build interoperable, multi-vendor

networks based on standards. Inter-dependent features are based on standards. Customers can

change features/products without worrying about changing their network design or architecture.

Purpose of This Document The purpose of this document is to help Dell Force10 SEs and customers integrate Dell Force10

equipment into legacy Cisco networks.

Table 1 : Dell Force 10 vs. Cisco Features

Cisco Proprietary

Feature

Dell Force10

Feature

Standard

Available? Notes

PVST+, RPVST PVST No Full interoperability

CDP LLDP IEEE

802.1AB Higher scalability & extensibility with LLDP

VTP GVRP IEEE

802.1p Extensible - built on top of GARP

ISL 802.1Q IEEE

802.1D ISL has greater header overhead

VMPS 802.1X + Mac-

Auth Bypass**

Extension

of IEEE

802.1X

Cisco supports 802.1X + Mac-Auth-Bypass

extension

CGMP IGMP RFC 1112,

2236 Cisco supports IGMP on all platforms

Page 5: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 3

EIGRP OSPF Yes Force10 recommends OSPF

Cisco also supports OSPF

PAgP LACP IEEE

802.3ad Cisco supports LACP

HSRP VRRP RFC 2238 Cisco supports VRRP

Netflow sFlow RFC 3176 More scalable

Cisco POE IEEE 802.3af IEEE

802.3af

Cisco switches and new IP phones support

the IEEE standard

VTP Force10 systems can operate in VTP transparent mode, passing traffic on untagged VLANs. Thus,

Force10 systems can co-exist with VTP-enabled networks. Force10 recommends deploying the

standards-based GVRP protocol.

VTP packets are passed untagged. Therefore, depending on the configuration, the FTOS native VLAN

or portmode hybrid capability may be required to pass such packets. The portmode hybrid command

sets a physical port or port-channel to accept both tagged and untagged frames.

FTOS Release 7.7.1.0 introduces native VLAN capability on physical interfaces, and FTOS Release

8.2.1.0 extends this to port-channel interfaces. In other words, starting with these releases, FTOS

transparently bridges VTP packets over physical and port-channel interfaces, allowing VTP to run

between devices connected to an FTOS switch/router.

Figure 1 : VTP Basic Test Setup

In this sample configuration, port-channel 1 and port-channel 2 are added to VLAN 100 as tagged,

while remaining in VLAN 1 as untagged. Untagged traffic arrives at port-channel 1 and is flooded out

Gigabit Ethernet interface 6/47 or port-channel 2.

Page 6: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 4

Figure 2: Port Channel FTOS Screenshot

FTOS Configuration

interface Port-channel 1

no ip address

portmode hybrid

switchport

channel-member GigabitEthernet 6/0

no shutdown

!

interface Port-channel 2

no ip address

portmode hybrid

switchport

channel-member GigabitEthernet 6/47

no shutdown

!

interface vlan 100

tagged port-channel 1-2

E-Series#show vlan

Codes: * - Default VLAN, G - GVRP VLANs, P - Primary, C - Community, I - Isolated Q: U - Untagged, T – Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description Q Ports * 1 Active U Po1(Gi 6/0)

U Po2(Gi 6/47) 100 Active T Po1(Gi 6/0)

T Po2(Gi 6/47)

Spanning Tree Protocols Dell Force 10 switches running FTOS support the different standard based spanning tree flavors such

as MSTP, RSTP, and PVST. These three different spanning tree variations are fully compatible with

other proprietary spanning tree extensions such as MST, PVST+, and RPVST+

The following section is divided into several scenarios:

• PVST (FTOS) and PVST+ (IOS)

• PVST (FTOS) and RPVST (IOS)

• RSTP and RPVST+

• MSTP

In our next revision, we aim to have two Catalyst 6509’s acting as root and backup root with dual

homed connections from the S4810’s. For now, the results obtained using the configuration on figure

3, are clear enough to give us an idea of how the different spanning tree modes interact with each

other.

Page 7: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 5

PVST (FTOS) and PVST+ (IOS) Dell Force 10’s PVST’s implementation is fully compatible with Cisco’s IOS implementation. The

following setup will demonstrate how PVST can be deployed in a mixed environment.

In figure 3, we have a typical deployment where all devices are connected and potentially create a

loop if spanning tree was not configured. The Cisco Catalyst 6509 is the root bridge and the Catalyst

4948 is the backup root bridge.

Figure 3 : Dell Force 10 and Cisco Catalyst 6509 PVST+ Test Setup

PVST is enabled on the Dell Force 10 switches, whereas PVST+ is enabled on the Cisco switch. PVST is

the IEEE nomenclature, and PVST+ is Cisco’s equivalent to the IEEE’s PVST version.

Switch Configuration Figure 4 : S55_1 PVST status and configuration

Page 8: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 6

Figure 5 : S4810_2 PVST status and configuration

In S4810_2, port 0/47 is blocking in an alternate role. The alternate role will switch to forwarding as

soon as the local root port fails.

All other ports are forwarding with the Cisco switch acting as the root switch for vlan 10. See figure 6.

Figure 6 : Catalyst 6509 PVST+ status and configuration

Page 9: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 7

Figure 7 : Catalyst 4948 PVST status and configuration

Convergence Test: 1. Shutdown the link between S55_1 (Gi 0/47) and Catalyst 6509 (Gi 2/47).

2. Bring back up the link between S55_1 and Catalyst 6509.

Results: IXIA traffic resumes under a second on link Gi 0/42 on S55_1. The blocking port (Gi 0/42) moves to

the forwarding state as expected. This is because no interaction is needed with another switch, i.e. no

BPDU exchanged is needed.

IXIA traffic resumes 30 seconds later. This is as expected since the link between the S55_1 and the

Cisco Catalyst 6509 go through the “listening” and “learning” states before moving onto the

“forwarding” state. Each state lasts 15 seconds and thus the 30 second traffic loss.

Page 10: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 8

Note: PVST (FTOS) and RPVST+ (IOS) configuration was also tested and the results were identical to

that of PVST (FTOS) and PVST+ (IOS).

RSTP and RPVST+ Using the same test setup (See Figure 3), RSTP and RPVST+ were enabled on the respective switches.

For this particular configuration, port Gi 0/42 on S55_1 assumes the alternate role and discarding

status after spanning tree settles down.

The same set of tests was performed and the results were as expected.

Switch Configuration Figure 8 : S55_1 RSTP configuration and status

Page 11: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 9

Figure 9 : S4810_2 RSTP configuration and status

Figure 10 : Catalyst 6509 RPVST+ configuration and status

Page 12: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 10

Figure 11 : Catalyst 4948 RPVST+ configuration and status

Convergence Test: 1. Shutdown Gi 0/47 on S55_1 and measure length of time required for traffic to resume.

2. Recover Gi 0/47 on S55_1 and measure length of time required for traffic to resume.

Results: Shutting down Gi 0/47 on S55_1 caused very little traffic interruption. Less than a second for traffic to

resume with Gi 0/42 taking over as the root port towards the Catalyst 6509.

However, reverting the process caused a 30 second traffic interruption. This is attributed to the fact

that the Cisco switches are running per-vlan spanning tree instances a proprietary implementation of

RSTP and the Dell Force 10 devices are running a single spanning tree instance. For more details on

the protocol exchanges please see the “Miscellaneous “ section of the document.

Page 13: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 11

MSTP MSTP was enabled on all the switches and allowed to converge. Port Gi 0/42 on S55_1 is blocking

while Gi 0/47 on the same switch is forwarding. The same set of tests was performed where port Gi

0/47 is shutdown and Gi 0/42 becomes active and traffic resumes under a second.

Gi 0/47 is brought back online and traffic and traffic resumes in under a second. Having all switches

be part of the same spanning tree instance improves the reconvergence times dramatically.

Implementation Note Some non-Dell Force10 systems which have hybrid ports participating in PVST+ transmit two kinds of

BPDUs: an 802.1D BPDU and an untagged PVST+ BPDU (Cisco proprietary BPDU packet). The PVST+

BPDU is sent to perform consistency checking and to inform all other potential Cisco switches about

the native VLAN configuration. Receiving switches consider only IEEE BPDUs (802.1D) for the native

VLAN computations and ignore the SSTP (Shared Spanning Tree Protocol) BPDUs.

Force10 systems do not expect either tagged or untagged PVST+ BPDUs on an untagged VLAN so

FTOS places the port in error-disable state by default when it receives this type of frame. This behavior,

while consistent with other vendors, might result in the network not converging.

To resolve this issue, which is documented in PR 84608, FTOS Release 8.2.1.0 introduces a CLI option

to set the error-disable state for receiving PVST BPDUs received on an untagged VLAN.

Force10 (conf-if-gi-4/0)# no spanning-tree pvst err-disable cause invalid-pvst-bpdu

The FTOS default remains placing the port in an error-disable state if a tagged or untagged PVST

BPDU is received on an untagged VLAN.

Note: If VLAN 10 is untagged and an FTOS system receives a PVST BPDU with VLAN tag 20, the BPDU

is simply dropped.

Page 14: Dell Force10 Interoperability Guide

Dell Networking Confidential Internal use only

Page 12

Miscellaneous Additional documentation on spanning tree interoperability can be found at the following link.

http://salesedge/browse under “Networking Dell Force 10 Dell Force 10 Whitepapers &

Technical Docs”

Port Channels Both FTOS and Cisco IOS support the Link Aggregation Control Protocol (LACP) for exchanging

information required to create a port-channel interface.

Figure 12 : Port Channel Setup

Figure 13 : Static Port Channel Configuration

6509 Configuration C300 Configuration

interface TenGigabitEthernet1/3 switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 10-15,97-99 switchport mode trunk no ip address load-interval 30 spanning-tree portfast disable channel-group 2 mode on ! interface TenGigabitEthernet1/4 switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 10-15,97-99 switchport mode trunk no ip address load-interval 30 spanning-tree portfast disable channel-group 2 mode on

interface TenGigabitEthernet 0/1 no ip address no shutdown ! interface TenGigabitEthernet 1/1 no ip address no shutdown ! interface Port-channel 2 description to-6509-Right no ip address switchport spanning-tree pvst vlan 11 cost 200000 channel-member TenGigabitEthernet 0/1 channel-member TenGigabitEthernet 1/1 rate-interval 30 no shutdown