68
Dental Laboratory Procera ® ready to use Tooth- and implant supported solutions procedures & products

Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

Dental LaboratoryProcera® ready to use™

Tooth- and implantsupported solutions

procedures & products

Page 2: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

Nobel Biocare is in compliance withISO 13485:2003 and Council Directive 93/42/EEC

Canadian Medical Devices Regulation

0086

For USA only: Federal law restricts this device to sale by or on the order of a licensed dentist or physician.All products are subject to change without notice.

Nobel Biocare AB and all production units are certified according to the Environmental Management System ISO 14001.

The procedures described herein must only be performed using components and instrumentsprovided by Nobel Biocare.

Nobel Biocare reserves the right to make any necessary alterations to the methods and procedures stated in this manual.

The devices advertised in this manual may not have been licensed in accordance with Canadian law

Some products may not be available in all markets. Please contact your local Nobel Biocare officefor current product assortment and availability.

Page 3: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

3

table of contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Provisional Solutions

Temporary Abutments and Copings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Immediate Provisional Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Solutions for Existing Teeth

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Procera® Crown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Procera® Laminate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Procera® Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Permanent Implant Solutions

Type of restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Procera® Esthetic Abutment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Procera® Abutment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Platform Shift/Procera® Abutment Zirconia PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Snappy Abutment™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Esthetic Abutment/Curvy™ Esthetic Abutment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Multi-unit Abutment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Abutment NobelPerfect®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Procera® Implant Bridge Zirconia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Procera® Implant Bridge Titanium. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Single Tooth Abutment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Narrow Profile Abutment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Easy Abutment™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

GoldAdapt Engaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

GoldAdapt Non-Engaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Overdenture Solutions

Gold Abutment Bar/Gold Coping Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Ball Abutment Titanium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Appendices

Terms you need to know. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Implant/Abutment Interface Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Abutment Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Model Techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Prosthetic Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Torque Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Page 4: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

The focus of this manual is the laboratory procedures. For information on laboratory procedures for NobelPerfect®

Groovy™, NobelDirect® Groovy, NobelDirect® Oval and NobelActive™, please see the relevant manual for eachsystem. For information on the clinical procedures, please see the Procedures & Products NobelEsthetics™ Procera®

ready to use™. Additional information on our prosthetic products can be found in the NobelEsthetics™ ProductCatalog.

4 Product illustrations are not to scale

introduction

Intro

ductio

n

Product News

New Procera® Crown Zirconia: now available in 0.4 mm thickness, for the esthetic zone and in fourdifferent shades.

New NobelActive™: internal connection usingconical seating and hexagon interlocking.

New Procera® Software 2.0: compatible with Vista,includes colored zirconia crowns and automaticallyset of finish line.

Platform Shifting™: use of narrower abutments onwider platforms.

Procera® Bridge Zirconia: bridge design within ∅ 60mm × H 20 mm. Precision milled with provenstrength.

Procera® Esthetic Abutment Selection Kit: the pre-designed Procera® Esthetic Abutment Zirconia areavailable for the anterior, pre-molar or molar region ineither straight or angled designs and high or lowemergence profiles. The Procera® Esthetic Abutmentsare now delivered without chimneys.

Procera® Implant Bridge: available for full arch inzirconia.

Curvy™ Esthetic Abutment: designed to stabilizethe soft tissue during implant treatment.

Welcome to Nobel BiocareNobel Biocare products are clinically proven dental solutions with documented, successful long-term results.

The implant-supported reconstruction is fabricated using specially developed and designed instruments and components of high precision and compatibility.

Also offered by Nobel Biocare are Procera® Personalized Esthetics, a highly esthetic product line designed for both implant and natural tooth preparation.

Page 5: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

5Product illustrations are not to scale

Temporary Abutments and CopingsThe Nobel Biocare Temporary Abutments and Copings used for the fabrication of provisionalrestorations are made of titanium or plastic.

Temporary Abutments Non-Engaging and TemporaryCopings Multi-unit are used to fabricate splintedmultiple-unit screw-retained restorations. TemporaryAbutments Engaging are used to fabricate eithersingle screw-retained restorations, or single orsplinted cement-retained temporary restorations.

Laboratory Procedure• Pour and fabricate a master model using

appropriate replicas. Articulate the master modelto the opposing jaw.

• Using a lab screw or guide pin, place and tightenthe appropriate Temporary Abutment or Copingto the replica.

• Check for occlusal clearance for veneering material and mark the length of any posts thatneed to be reduced. When fabricating a splintedcement-retained temporary restoration somereduction in axial wall alignment may be requiredfor bridge draw.

• Remove abutments or copings from the modeland attach suitable protection analogs. Makeadjustments using disks and/or burs.

• If you are producing a cement-retained restoration,you have to block out any undercut grooves withsuitable block-out material.

• If a metal framework is required to strengthen atemporary cement-retained bridge, a conventionalcrown and bridge technique can be processed onwhich temporary material is applied.

• Process the temporary restoration using conventional laboratory technique.

Clinical information:• Temporary Abutments titanium are torqued to 35

Ncm, Temporary Copings titanium are torqued to15 Ncm and Temporary Abutments and Copingsplastic are manually torqued.

• The temporary titanium abutments are deliveredwith definitive abutment screws, that can be usedwith Procera® Implant Bridges titanium.

Protection Analogs – Implant

Level and Multi-unit

Temporary Abutments and Copings

Handle for Protection Analogs

Temp

orary A

butm

ents an

d C

op

ing

s

provisional solutions

Page 6: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

6 Product illustrations are not to scale

Imm

ediate Pro

vision

al Imp

lants

Immediate Provisional ImplantThe Immediate Provisional Implant is placed betweenthe permanent implants at the time of surgery. Theprovisional restoration is then cemented directly onthese one-piece implants.

An implant level impression is made by “picking up”an Immediate Provisional Implant Coping.

• Snap an Immediate Provisional Implant Analoginto each coping and pour the impression in hard stone.

• Transfer the copings from the impression to theanalogs on the model.

• Mount the case in an articulator.

• Create a full contour wax-up or use denture teethin the area that needs to be restored. The dentistwill sometimes use the existing denture as atemporary prosthesis. This method is similar to areline, but the flanges will have to be removedfrom the denture since the denture is to becemented to the implants.

• Make a matrix and process the provisional bridgein acrylic.

For more detailed information on Immediate Provisional Implants, see the Immediate ProvisionalImplant Clinical Procedure & Product Catalog. Attaching analogs to impression

Immediate ProvisionalImplant Analog

Immediate ProvisionalImplant Coping

Final restoration

provisional solutions

Page 7: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

7Product illustrations are not to scale

Intro

ductio

n

The objective of Nobel Biocare Procera® PersonalizedEsthetics is to provide customized prostheticcomponents for case selections demanding highesthetics and excellent fit.

Procera® Personalized Esthetics include:

• Procera® Crown: alumina or zirconia coping,customized but still industrially produced,ensuring predictable results. Procera® CrownAlumina is available in two thicknesses; 0.4 and0.6 mm and in two colors; white and translucent.Procera® Crown Zirconia is available in twothicknesses; 0.4 and 0.7 mm and in four colors;white, light, medium and intense.

• Procera® Laminate: alumina, the core is only 0.25 mm thick, yet able to mask discolored teeth.

• Procera® Bridge Zirconia: designed to fit into adisc of ∅ 60 mm × height 20 mm, 2–14 units,precision milled, with proven strength.

• Procera® Bridge Alumina: two to four unitbridges, especially appropriate as an estheticsolution in the anterior.

It is essential to accurately document the color of the adjacent teeth according to the Vita shade guide,as this will provide the optimum match for theveneering porcelain that is best-suited to Procera®

restorations.

Thereafter, the NobelRondo™ procedure is an ideal alternative that offers unlimited possibilities for achieving customized esthetics, e.g. in terms of the hue, chroma and value of the teeth.

6 steps of shade selection with NobelRondo™:

1. Selection of the NobelRondo™ shade group2. Selection of the basic hue3. Variations of color intensity4. Inner structures of the tooth5. Variations of lightness (value) and contrasts6. Texture and shine of the tooth surface

For more information see the NobelRondo™ Manual.

solutions for existing teeth

Page 8: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

solutions for existing teeth

8 Product illustrations are not to scale

Procera

®C

row

n

1. Model• A standard C&B impression is received.

• Pour the model in hard die stone or epoxy.

2. Create the Die• Pin and die the model using standard laboratory techniques.

• Ensure the model height is sufficient (approximately 10 mmbelow the margin) so that scannable dies can be produced.

• Create an undercut no deeper than 0.5 mm under the margin.The length of the undercut should be a minimum of 1.5 mmto allow the scanner stylus tip to travel easily on the die.

• Make sure that no undercuts are present above the finish line.

Note: If you see undesirable elements (divots, cavities, sharp edges,etc.), block them out with wax to avoid damaging the stylus.

• Use die hardener, but not die spacer, since the Procera®

process already compensates for the cement space.

Procera® CrownZirconia

Indications • Any position of the mouth – including the posterior

• Natural teeth and implant restorations.

• Procera® Crown Zirconia, 0.4 mm, is indicated foruse in the esthetic region, premolar to premolar.

For use in the esthetic region, Procera® CrownZirconia is now available in four different shades

For situations where you need to build up the copingfor extra porcelain support, you should use theProcera® Crown CAD or Wax-up techniques.

When using the wax-up technique to create your

Procera® Crown, build up a wax outer layer with:

• Minimum thickness of 0.7 mm.

• Maximum dimensions of 15 mm × 14 mm.

Alumina

Indications• Any position of the mouth – including the posterior.

• Natural teeth and implant restorations.

• Procera® Crown Alumina, 0.4 mm, is indicated foruse in the esthetic region, premolar to premolar.

For situations where you need to build up the copingfor extra porcelain support, you should use theProcera® Crown CAD or Wax-up techniques.

When using the wax-up technique to create yourProcera® Crown, build up a wax outer layer with:

• Minimum thickness of 0.6 mm.

• Maximum dimensions of 16 mm × 14 mm.

Page 9: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

9Product illustrations are not to scale

Procera

®C

row

n

4. Concluding ProcedureAfter delivery of the Procera® Crown from the Nobel Biocare production facility:

• If necessary, make minor adjustments withdiamond impregnated finishing tools with fine grit size under low pressure and using copiuswater irrigation.

• If necessary, sandblast using maximum 1 bar of pressure utilizing aluminum oxide at anapproximate distance of 10 mm.

• 110 µm for zirconia crowns.

• 50 µm–110 µm for alumina crowns.

• Apply appropriate NobelRondo™ dental ceramic(see the NobelRondo™ Ceramic Concept andProcedures CD or manual or the NobelRondo™

Press manual).

• Clean in an ultrasonic bath before sending the finished product to the clinic.

solutions for existing teeth

3. Scan the die• Open the Procera® Software and follow the instructions

in the tutorial.

• Scan the die using the Procera® Scanner according to thetutorial found within the software.

• Follow the instructions in the tutorial for:– Using the Procera® Software CAD Design Application– Dispatching an order

Page 10: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

10 Product illustrations are not to scale

Procera

®Lam

inate

1. Model• A standard C&B impression is received.

• Pour the model in hard die stone or epoxy.

2. Create the Die• Pin and die the model using standard laboratory

techniques.

• Ensure the model height is sufficient (approximately 10 mm below the margin) so that scannable dies can be produced.

• Create an undercut no deeper than 0.5 mmunder the margin. The length of the undercutshould be a minimum of 1.5 mm to allow thescanner stylus tip to travel more easily on the die.

• Make sure that no undercuts are present abovethe finish line.

• Wax should be used to build up the die on thelingual side to allow the scanner probe tip to travel easier on the die.

Note: If you see undesirable elements (divots, cavities,sharp edges, etc.), block them out with wax to avoiddamaging the stylus.

• Use die hardener, but not die spacer, since theProcera® process already compensates for thecement space.

Procera® LaminateAlumina

Indications • Any position of the mouth where the preparation

requirements can be respected

solutions for existing teeth

Page 11: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

solutions for existing teeth

11Product illustrations are not to scale

Procera

®Lam

inate

3. Scan the die• Open the Procera® Software and follow the

instructions in the tutorial.

• Scan the die using the Procera® Scanner according to the tutorial found within the software.

• Follow the instructions in the tutorial for:– Using the Procera® Software CAD Design

Application– Dispatching an order

4. Concluding ProcedureAfter delivery of the Procera® Laminate from theNobel Biocare production facility:

• Apply NobelRondo™ Alumina dental ceramic (see the NobelRondo™ Ceramic Concept andProcedures CD or manual).

• The optimal surface for bonding is the originallydelivered surface from Procera® production.

If contaminated or modified, the surface can bereconditioned by sandblasting for a maximum of15 seconds at max. 1 bar of pressure with 50–110micron grit alumina sand at an approximatedistance of 10 mm.

• Clean in an ultrasonic bath before sending thefinished product to the clinic.

Page 12: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

20 mm

∅ 60 mm min. height 3 mmmin. area 6 mm2

min. height 3 mmmin. area 8 mm2

12 Product illustrations are not to scale

Procera

®B

ridg

e

1. Model• A standard impression is received.

• Pour the model in hard die stone or epoxy.

2. Create the Die• Pin and die the model using standard laboratory

techniques.

• Ensure the model height is sufficient(approximately 10 mm below the margin) so thatscannable dies can be produced.

• Create an undercut no deeper than 0.5 mm underthe margin. The length of the undercut should be aminimum of 1.5 mm to allow the scanner stylus tipto travel easily on the die.

Continued on the next page.

Procera® BridgeZirconia

Indications • Indicated for all positions in the mouth.

• A bridge designed to fit into a disc of ∅ 60 mm × H 20 mm.

• The connector in the anterior region must have aminimum cross-sectional area of 6.0 mm2. In posterior a min. area of 8mm2 is required.

• Natural teeth and implant restorations.

Contraindications• Cases where the anterior/posterior cantilevers have

a length of more than one unit.

• Cases with more than two pontics betweensupporting teeth/abutments.

• Bruxism.

Alumina

Indications• Indicated for use in the esthetic region, premolar

to premolar.

• Two-to-four unit bridges.

• The connector in the anterior region must have aminimum area of 6.0 mm2.

Contraindications• No cantilevers and maximum one pontic between

supporting teeth/abutments.

• Bruxism.

solutions for existing teeth

Page 13: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

13Product illustrations are not to scale

Procera

®B

ridg

e

2. Create the Die – cont.• Make sure that no undercuts are present above the

finish line.

Note: If you see undesirable elements (divots, cavities,sharp edges, etc.), block them out with wax to avoiddamaging the stylus.

• Use die hardener, but not die spacer, since the Procera® process already compensates for thecement space.

• If you decide to use a bite index, make this of ahard material, e.g. light-cured resin.

3. Scan the Dies• Open the Procera® Software and follow the instructions

in the tutorial.

• Scan the die using the Procera® Forte Scanneraccording to the tutorial found within the software.

• Follow the instructions in the tutorial for:– Using the Procera® Software CAD Design Application– Dispatching an order

• Always keep in mind to design a proper build up forsupport of the veneering material.

4. Concluding ProcedureAfter delivery of the Procera® Bridge from the NobelBiocare production facility:

• If necessary, make minor adjustments with diamondimpregnated finishing tools with fine grit size underlow pressure and using copious water irrigation.

• Sandblast using max. one bar of pressure utilizingaluminum oxide at an approximate distance of 10 mm:110 µm for zirconia bridges.50–110 µm for alumina bridges.

• Apply appropriate NobelRondo™ dental ceramic (seethe NobelRondo™ Ceramic Concept and Procedures CD or manual or the NobelRondo™ Press manual).

solutions for existing teeth

Page 14: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

14 Product illustrations are not to scale

Type o

f Resto

ration

Cement-Retained

Procera® EstheticAbutment

Procera® Abutment

Snappy Abutment™

Esthetic Abutment/Curvy™ EstheticAbutment

Single Tooth Abutment

Page 16

Page 17

Page 22

Page 24

Page 35

Single Multiple

permanent implant restorations

NobelPerfect®

Abutment Page 28

Overdenture

Permanent Implant Restorations

With simple and predictable clinical procedures as outlined in the following pages, excellent esthetic resultsand improved long-term performance can be achieved.

The Procera® System provides completely individualized prosthetics with unbeatably precise fit for abutments and bridges. By combining the Procera® manufacturing technique with Alumina and Zirconiaceramics, an unrivaled combination of biocompatibility, beauty and strength is guaranteed. Both Aluminaand Zirconia refract and transmit light in much the same way as a natural tooth, thereby giving therestoration a natural looking appearance. In fact, the end result is often an improvement on nature.

Our vast range of preproduced prosthetics offers easy and beautiful esthetics for all indications whether it is single tooth, several teeth or overdenture solutions, cement-retained or screw-retained.

Narrow ProfileAbutment Page 36

Page 15: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

Overdenture

Cement-Retained

Page 45

Page 45

Page 47

Page 26

Page 29

Page 39

Page 43

15Product illustrations are not to scale

Type o

f Resto

ration

permanent implant restorations

Single Multiple Overdenture

Ball AbutmentTitanium

Multi-unitAbutments Titanium

Multi-unit AngledAbutments Titanium

Gold Coping BarMulti-unit

GoldAdaptNon-Engaging

GoldAdaptEngaging

Gold Abutment Bar

Procera® ImplantBridge

Multi-unit Abutment

Screw-Retained

GoldAdapt Engaging

Easy Abutment™

Page 39

Page 37

Page 16: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

Note: If modifying a Procera® Esthetic Abutment, make sure that thethickness of the ceramic material is at least 1.0 mm. This thickness limit is applicable up to a height of 3 mm above implant level.

NobelActive™

16 Product illustrations are not to scale

permanent implant restorations

Procera

®Esth

etic Ab

utmen

t 1. Model• A standard C&B impression is received.

• Pour the model in hard die stone or epoxy.

• Pin and die the model using standard laboratorytechniques.

Prosthetic AlternativesProcera® Crown (see page 8)Procera® Bridge (see page 12)Standard C&B restoration (see below)

2. Restoration• Fabricate the restoration framework using standard

C&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

• The abutments can be stored in the Procera® Esthetic Abutment Selection Kit which includes: Screwdriver Manual Unigrip™ 36 mmHandle for Protection AnalogProtection Analog NP

Protection Analog RP

Protection Analog WP

Procera® Esthetic AbutmentZirconia

Indications • Single tooth or multiple unit implant restorations• Single use only• Cement-retained

Procera® Esthetic Abutments are available for the anterior, pre-molar or molarregion in either straight or angled designs and high or low emergence profiles.

Internal Connection

External Connection

Page 17: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

17Product illustrations are not to scale

Procera

®A

butm

ent1. Model

• An implant level impression is received with an implantreplica.

• Confirm the position of the implant level impression copingand implant replica assembly in the impression.

• Pour and fabricate a soft tissue master model.

2b. Regarding Procera® Abutment CADTo facilitate correct abutment angulation and measurements,insert a Guide Pin and T-bar into the replica. These arecontained in the Procera® Abutment 3D CAD Kit and will help you to feed correct data into the Procera® Software 3D CAD Design application.

2a. Regarding Procera® Abutment Wax-up• Create the abutment in a pattern resin or a hard wax. Use

a temporary component (engaging) as a foundation for theabutment pattern. For NobelActive™, use a Procera® wax-upsleeve engaging NobelActive™ Internal.

• You must respect certain dimensions in the waxedframework depending on which Procera® product you wish to fabricate:– For ceramic abutments NP – maximum dimensions are

4 mm × 12 mm radius × height (r × h)– For ceramic abutments RP/WP – maximum dimensions

are 5 mm × 15 mm (r × h)– For titanium abutments NP – maximum dimensions

are 5 mm × 12 mm (r × h)– For titanium abutments RP/WP – maximum dimensions

are 7.5 mm × 15 mm (r × h)

Procera® AbutmentZirconia, Titanium

Indications • Single tooth or multiple unit

implant restorations• Cement-retained

Internal ConnectionExternal Connection

permanent implant restorations

NobelActive™

Page 18: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

18 Product illustrations are not to scale

Procera

®A

butm

ent

3. ScanningNote that the scanning procedure is only necessaryfor Procera® Abutment Wax-up.

• Open the Procera® Software and follow theinstructions in the tutorial.

• Scan the die using the Procera® Scanner accordingto the tutorial found within the software.

• Follow instructions in the tutorial for:– Using the Procera® Software CAD Design

Application– Dispatching an order

4. Concluding ProcedureAfter delivery of the Procera® Abutment from theNobel Biocare production facility:

Ceramic Abutments• If necessary, make minor adjustments with diamond

bur or flex disc with fine grit size under low pressureand with copious water irrigation.

• When designing/preparing Procera® AbutmentZirconia, make sure that the thickness of theceramic material is at least 1.0 mm. This thicknesslimit is applicable up to a height of 3 mm aboveimplant level. For Procera Esthetic abutmentNobelActive; never modify the area of theabutment marked in red. Do not modify theabutment below the dimensions shown.

• Sandblast using max. one bar of pressure utilizing110 µm aluminum oxide, at an approximatedistance of 10 mm.

• Clean in an ultrasonic unit.

Titanium Abutments• If necessary, make minor adjustments, with a carbide

bur. Rubber wheels are used for the collar part.

• Clean in an ultrasonic unit.

permanent implant restorations

Page 19: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

19Product illustrations are not to scale

Procera

®A

butm

ent

permanent implant restorations

Procera® Abutments for other implant systemsProcera® Abutments are available in both zirconia and titanium for;

• Straumann® Regular Neck 4.8 mm implants.

• Camlog® Implant Systems 3.3, 3.8, 4.3, 5.0, 6.0 mm.

Procera® Abutments are available in titanium for;

• Astra Tech® Implant System 4.5ST, 5.0ST mm.

• Follow the laboratory procedures for Procera® Abutment andthe clinical procedures for each respective implant system.

Page 20: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

permanent implant restorations

Procera

®A

butm

ent Z

ircon

ia PS

2a. Regarding Procera® Abutment Wax-up• Create the abutment in a pattern resin or a hard wax. Use a

temporary component as a foundation for the abutmentpattern.– For Implant Replica PS WP–RP, use Temporary Abutment

Plastic Engaging Bmk RP with Abutment Screw PS WP–RP

– For Implant Replica PS RP–NP, use Procera® Wax-up Sleeve PS RP–NP with Abutment Screw PS RP–NP

• You must respect certain dimensions in the waxed frameworkdepending on which Procera® product you wish to fabricate: – For ceramic abutments NP, maximum dimensions are 4 mm

∅ 12 mm radius ∅ height (r × h)– For ceramic abutments RP/WP, maximum dimensions are

5 mm ∅ 15 mm (r × h)

1. Model• An implant level impression is received with an Impression

Coping PS.

• Confirm the position of the implant level impression copingand Implant Replica PS assembly in the impression.

• Pour and fabricate a soft tissue master model.

Platform shiftPlatform Shifting™ is the concept of “stepping down” the size of an implantplatform to increase the volume of soft tissue around the implant platform duringimplant treatment.

In practice, Platform Shifting™ adapters convert regular (RP) and wide (WP)platform implants to narrow (NP) and regular (RP) platform implants, respectively.

Platform Shifting™ also results in shifting from an Internal platform, a tri-lobe, onthe implant interface to an External platform, a hexagon, on the abutmentinterface, i.e. shifting from a NobelReplace™ fitting to a Brånemark System® fitting.Procera® Abutment Zirconia and Procera® Esthetic Abutment Zirconia PS are all theavailable abutments within the concept. They are used together with special screwsthat have the length and design to go into implants with internal connections.

Implant interface:RP Replace® fitting(Tri-lobe)

Abutment Screw:RP Replace® design

Abutmentinterface:NP Brånemarkfitting (Hexagon)

Procera® Abutment Zirconia PS

20 Product illustrations are not to scale

Page 21: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

permanent implant restorations

4. Concluding ProcedureAfter delivery of the Procera® Abutment from the Nobel Biocare production facility:

• If necessary, make minor adjustments with diamond bur or flex disc with fine grit size under low pressure and withcopious water irrigation.

• When designing/preparing Procera® Abutment Zirconia,make sure that the thickness of the ceramic material is at least 1.0 mm. This thickness limit is applicable up to a height of 3 mm above implant level.

• Sandblast using max. one bar of pressure utilizing 110 µm aluminum oxide, at an approximate distance of 10 mm.

• Clean in an ultrasonic unit.

3. ScanningNote that the scanning procedure is only necessary forProcera® Abutment Wax-up. • Open the Procera® Software and follow the instructions in the

tutorial.

• Scan the die using the Procera® Scanner according to thetutorial found within the software.

Note: Use the ordinary BmkSyst® Lab Screw to attach the wax-uppattern in the implant platform replica.

• Follow instructions in the tutorial for:– Using the Procera® Software CAD Design Application– Dispatching an order

2b. Regarding Procera® Abutment CADTo facilitate correct abutment angulations and measurements,insert a T-bar into the replica. It is contained in the Procera®

Abutment 3D CAD Kit and will help you to feed correct datainto the Procera® Software 3D CAD Design application.

Procera

®A

butm

ent Z

ircon

ia PS

21Product illustrations are not to scale

Page 22: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

22 Product illustrations are not to scale

Snap

py A

butm

ent

permanent implant restorations

1. Model• The impression is received with the embedded

Snappy Abutment™ Impression Coping and anAbutment Replica Snappy Abutment™.

• Confirm the placement of the replica in theimpression coping, ensuring correct alignment ofthe three grooves.

• Pour and fabricate a soft tissue master model.

Prosthetic AlternativesProcera® Crown (see page 8)Procera® Bridge (see page 12)Plastic/Temporary Coping Snappy Abutment™ (see below)

Snappy Abutment™

Titanium

Indications • Single tooth or multiple unit implant restorations ideal for posterior

restorations• Cement-retained

The NobelDirect® Posterior Implant has an integrated abutmentportion, which is identical to the Snappy Abutment™ and thus uses the same prosthetic products.

Internal ConnectionExternal Connection

NobelActive™

Page 23: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

23Product illustrations are not to scale

Snap

py A

butm

ent

2. Restoration• Place the plastic/temporary coping on the abutment.

For single tooth restorations, use the engagingplastic/ temporary coping. For multiple unitrestorations, use the non-engaging plastic/temporary coping.

permanent implant restorations

• Fabricate the restoration framework using standardC&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

• Wax the framework around the plastic coping.

Page 24: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

24 Product illustrations are not to scale

Esthetic A

butm

ent/C

urvy™

Esthetic A

butm

ent

permanent implant restorations

1. Model• A standard C&B impression is received• Pour the model in hard die stone or epoxy• Pin and die the model using standard laboratory

techniques

Prosthetic AlternativesProcera® Crown (see page 8)Procera® Bridge (see page 12) Plastic/Temporary Coping Esthetic Abutment (see below) Not applicable for Curvy™ Esthetic Abutment and NobelActive™.

Standard C&B restoration

Esthetic Abutment/Curvy™ Esthetic AbutmentTitanium

Indications • Single tooth or multiple unit implant restoration• Cement-retained

The Esthetic Abutment is designed with a scalloped collar that profiles natural soft tissue contours with various collar heights available depending on the implant platform and system. The Curvy™ Esthetic Abutment is designed with 1) a scalloped margin that profiles soft tissue contours and 2) a concave collar that is designed to stabilize soft tissue and prevent recession, which is desirable for soft tissue seal and an esthetic outcome.The following description is based on straight Esthetic Abutments.The same procedures are used for the 15° Esthetic Abutments and the Curvy™ Esthetic Abutments, straight and 15°.

Internal ConnectionExternal ConnectionEsthetic Abutment

Curvy™ Esthetic Abutment

Esthetic Abutment for NobelActive™

Page 25: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

25Product illustrations are not to scale

Esthetic A

butm

ent/C

urvy™

Esthetic A

butm

ent

permanent implant restorations

2. Restoration• Place the plastic/temporary coping on

the abutment. Not applicable for Curvy™ EstheticAbutment and NobelActive™.

• Wax the framework around the plastic/temporarycoping. Regarding Curvy™ Esthetic Abutment andNobelActive™, wax around the dies.

• Fabricate the restoration framework using standardC&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Page 26: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

26 Product illustrations are not to scale

Multi-un

it Ab

utmen

t

permanent implant restorations

Straight Multi-unit AbutmentThe Multi-unit Abutment extends straight up from the implantwhen no angulations correction is necessary. Straight Zygoma Multi-unit Abutments are available forBrånemark System® Zygoma Implants.

17° or 30° Multi-unit AbutmentThe angled Multi-Unit Abutment is intended for use when theaxial alignment of the implant is unfavorable in relation to thedesired position of the screw channel.

Available for the NP and RP implants are 17° angled Multi-unitAbutments and additional 30° angled Multi-unit Abutments areavailable for RP implants. 17° Zygoma Multi-unit Abutments areavailable for Brånemark System® Zygoma Implants.

Note: Use the same laboratory components for Zygoma Multi-unit Abutments as for ordinary Multi-unit Abutments.

1. Model• An abutment level impression is received with

Abutment Replicas Multi-unit.

Note: The abutments must be placed before theimpression is taken. The torque and screws aredescribed in the table on page 61.

• Confirm the placement of the abutment replicas in the impression copings.

• Pour and fabricate a soft tissue master model.

Multi-unit AbutmentTitanium

Indications • Multiple unit restorations• Desire for greater ease of retrievability• Screw-retained

Internal Connection External Connection

Straight 17°/30°

17°/30°Straight

Prosthetic AlternativesProcera® Implant Bridge Titanium (see page 32)Gold Coping Multi-unit (see below)

NobelActive™

Page 27: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

27Product illustrations are not to scale

Multi-un

it Ab

utmen

t

permanent implant restorations

Alloy Recommendations Gold Coping:

Melting range: 1400–1490°C/2550–2720°F.Coefficient of thermal expansion: 12 µm/m*°K.

Recommended casting alloys:Conventional gold alloys: High gold content (min 75% Au + Pt metal) alloys, standard ISO 1562 type 4.Ceramic bonding alloys: High gold content (min 75% Au) alloys,standard ISO/DIS 9693, NIOM type A.Soldering in the range of 800–890°C/1472–1634°F.

2. Restoration• Attach the gold copings to the abutment replicas

using guide pins or lab screws.

• Reduce the height or axial wall of the plastic sleevesas desired. They can be shortened all the way downto the gold copings if needed.

• Wax the framework around the gold copings.

Note: The gold coping is made from a non-oxidizingalloy. Cracking of porcelain may occur if it is applieddirectly to the gold coping. Make sure the wax coversthe gold coping with a minimum wax thickness or 0.5 mm. A reduction to 0.3 mm can be made aftercasting.

• If needed, remove the framework from themodel, attach protection analogs using labscrews, and carefully wax around base of goldcopings for adequate coverage.

• Fabricate the restoration framework using standard C&B techniques.

• Complete the framework with ceramic and returnto dentist for final delivery.

Page 28: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

28 Product illustrations are not to scale

Ab

utmen

t No

belPerfect

®

permanent implant restorations

1. Model• An implant level impression is received with an

implant replica.

• Confirm the position of the implant levelimpression coping and implant replica assembly inthe impression.

• Pour and fabricate a soft tissue model.

• Attach a straight Abutment NobelPerfect® or a 10°Abutment NobelPerfect® to the implant replica andsecure it with a lab screw.

Prosthetic AlternativesProcera® Crown (see page 8)Ceramic Coping NobelPerfect® (see below)Plastic Coping NobelPerfect® (see below)

2a. Restoration with Ceramic Coping NobelPerfect®

• Complete the restoration with NobelRondo™ ceramicand return to the dentist for final delivery.

Abutment NobelPerfect®

Titanium

Indications • The Abutment NobelPerfect® is used in esthetically demanding areas

from premolar to premolar• Single tooth or multiple unit implant restorations• Cement-retained

2b. Restoration with Plastic Coping NobelPerfect®

• Wax the framework around the plastic coping.

• Fabricate the restoration framework using standardC&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Internal Connection NobelPerfect®

Straight 10º

Page 29: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

20 mm

∅ 60 mm

29Product illustrations are not to scale

Procera

®Im

plan

t Brid

ge Z

ircon

ia

permanent implant restorations

2. Create the Framework and Index• Make a tooth set-up.

• Make a silicone index of the tooth set-up.

• Make an acrylic framework using non-engagingtemporary abutments. Wax should not be used.

• Reduce the acrylic framework to the desired shape.

1. Model• An implant level impression with implant replicas

is received.

• Confirm the position of the implant impressioncopings and replicas assemblies in the impression.

• Pour and fabricate a master model with soft tissue.

• The soft tissue must be at least 2 mm thick so thatthe implant replicas will stick up at least 2 mmfrom the plaster model.

Procera® Implant Bridge ZirconiaIndications • Implant level only• Multiple unit restorations• Indicated for all positions in the mouth• Screw-retained• A bridge designed to fit into a disc of ∅ 60 mm × H 20 mm• Requires a minimum of 4 × 2.5 mm connector between units

(Height × Width) with a minimum cross-sectional area of 8 mm2

Contraindications• Cases where the mesial/distal cantilevers have a length of more

than one unit• Cases with more than two pontics between supporting implants• Bruxism

Platform Options• NobelReplace™ (NP, RP, WP, 6.0)• Brånemark System® (NP, RP, WP)• NobelActive™ Internal (NP, RP)• 3i® 3.75• Lifecore® Biomedical Restore 3.75• Zimmer® Dental Taper-Lock 4.0• Sterngold® Implamed 3.75

Prosthetic Options• NobelRondo™ Zirconia dental ceramic.

Page 30: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

30 Product illustrations are not to scale

Procera

®Im

plan

t Brid

ge Z

ircon

ia

permanent implant restorations

3. Scan the Model and FrameworkThe following instructions mimic the Design Tabflow in the Procera® Software:

• Tighten the Position Locators Model firmly on thesteamcleaned master model and attach the modelfirmly to the bridge holder. Make sure that theimplant replicas and locators are free from wax or dust, since the precision will otherwise becompromised. For example, one hair is about 70 µm, +/- 30 µm, thick, and even this smalldistance can compromise the result.

• Scan the position of the Position Locators on themodel.

• In the Procera® Software, define what interfacesshould be used for each implant position.

• Mount the acrylic framework into the Procera®

Implant Bridge holder.

a. Drill holes in the end points of the framework.b. Attach 20 mm guide pins, in the Holder

Procera® Implant Bridge. The guide pins needto protrude from the holder enough, so theycan be scanned by the stylus.

c. Adjust the holder so that the guide pins will fit into the holes in the framework.

d. Attach the guide pins to the framework withself-curing acrylic. Make sure that theframework lies as flat as possible. Don’t movethe framework and pins until the acrylic is hard.

Continued on next page.

Design limitations in the Procera® Software• To ensure that the implant interface is not too thin,

a safety-zone in the shape of a cylinder of 1.0 mmmaterial thickness and 3 mm in height will overridecustomer design, if necessary.

• The minimum space between two position locatorsis 2 mm.

3 mm

1.0 mm

Page 31: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

31Product illustrations are not to scale

Procera

®Im

plan

t Brid

ge Z

ircon

ia

permanent implant restorations

4. Concluding ProcedureAfter delivery of the Procera® Implant Bridge from the Nobel Biocare production facility:

• If necessary, make minor adjustments usingdiamond impregnated finishing tools with fine gritsize, under low pressure and using copious waterirrigation.

• Sandblast using one bar of pressure utilizing 110 µm aluminum oxide, at a distance ofapproximately 10 mm.

• Apply NobelRondo™ Zirconia and Gingiva dentalceramic (see the NobelRondo™ Ceramic Conceptand Procedures CD or manual).

Note: Abutment screws are not included.Note: Only the original ceramic abutment screw must be used!

Note: Narrow spaces and small irregularities that the2.5 mm stylus can’t reach will not be defined in themilled bridge, but have to be adjusted after deliveryfrom the Nobel Biocare production facility.

3. Scan the Model and Framework – cont.• Install Position Locators Bridge into the framework

and scan their position. Make sure that theframework and the locators are free from wax ordust, since the precision will otherwise becompromised.

• Remove the Position Locators from the frameworkand fill out the screw holes with wax.

• Scan the underside of the framework.

• Flip the framework holder to expose the topside ofthe framework.

• Scan the topside of the framework.

• The scans are fused together in the Procera®

Software and the resulting scanned Procera®

Implant Bridge is viewed.

• View, approve and send the Procera® ImplantBridge file to the Procera® production facility.

Page 32: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

2. Create the Framework and Index• Make a tooth set-up.

• Make a silicone index of the tooth set-up.

• Make an acrylic framework using non-engagingtemporary abutments/cylinder. Wax should not beused.

• Reduce the acrylic framework to the desired shape.

1. Model• An implant or abutment level impression with

replicas is received.

• Confirm that the impression copings and thereplicas are put together and positioned correctlyin the impression.

• Pour and fabricate a master model with soft tissue.

• The soft tissue must be at least 2 mm thick so thatthe replicas stick up at least 2 mm from the plastermodel.

Prosthetic Options• Wrap-around.• Traditional acrylic.• Ti-dental ceramic.

32 Product illustrations are not to scale

Procera

®Im

plan

t Brid

ge Titan

ium

permanent implant restorations

Procera® Implant Bridge TitaniumIndications • Implant level, abutment level or mixed• Multiple unit restorations• Screw-retained

Platform Options• NobelReplace™ (NP, RP, WP, 6.0)• Brånemark System® (NP, RP, WP)• NobelActive™ Internal (NP, RP)• Straumann® Dental Implant System Regular Neck 4.8 (implant level)• Straumann® Dental Implant System Wide Neck 6.5 (implant level)• 3i® 3.75 (implant level)• Lifecore® Biomedical Restore 3.75 (implant level)• Zimmer® Dental Taper-Lock 4.0 (implant level)• Sterngold® Implamed 3.75 (implant level)• Ankylos® Implant System 3.5, 4.5, 5.5, 7.0 (abutment level)• Astra Tech® Implant System 4.5ST, 5.0ST (abutment level)• Camlog® Implant System 3.3, 3.8, 4.3, 5.0, 6.0 (abutment level)

Design limitations in the Procera® Software• The minimum space between two Position

Locators is 2 mm.

Page 33: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

33Product illustrations are not to scale

Procera

®Im

plan

t Brid

ge Titan

ium

permanent implant restorations

3. Scan the Model and FrameworkThe following instructions mimics the Design Tab flowin the Procera® Software:

• Tighten the Position Locators Model firmly on thesteamcleaned master model and attach the modelfirmly to the bridge holder. Make sure that thereplicas and locators are free from wax or dust,since the precision will otherwise be compromised.For example, one hair is about 70 µm, +/- 30 µm,thick, and even this small distance can compromisethe result.

• Scan the position of the Position Locators on themodel.

• In the Procera® Software, define what interfacesshould be used for each implant/abutment position.

• Mount the acrylic framework into the Holder Procera®

Implant Bridge.a. Drill holes in the end points of the framework.b. Attach 20 mm guide pins, in the Holder Procera®

Implant Bridge. The guide pins need to protrudefrom the holder enough, so they can be scannedby the stylus.

c. Adjust the holder so that the guide pins will fit into the holes in the framework.

d. Attach the guide pins to the framework withself-curing acrylic. Make sure that the frameworklies as flat as possible. Don’t move theframework and pins until the acrylic is hard.

• Install Position Locators Bridge into the frameworkand scan their position, make sure that theframework and the locators are free from wax ordust, since the precision will otherwise becompromised.

• Remove the Position Locators from the frameworkand fill out the screw holes with wax.

• Scan the underside of the framework.

• Flip the framework holder to expose the topside ofthe framework.

• Scan the topside of the framework.

Page 34: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

34 Product illustrations are not to scale

Procera

®Im

plan

t Brid

ge Titan

ium

permanent implant restorations

4. Concluding ProcedureAfter delivery of the Procera® Implant Bridge from the Nobel Biocare production facility:

• Grind the titanium framework with hard metal bursonly in one direction.

• Sandblast using 2.5 bars of pressure utilizing 250 µmaluminum oxide, at a 45º angle.

• Clean in an ultrasonic unit with distilled water for 5 minutes.

• Let the framework dry in room temperature 10–30 minutes before applying the bonding material.

• Apply porcelain following the instructions of theporcelain manufacturer.

Note: Abutment screws/Prosthetic screws are not included.

Note: Narrow spaces and small irregularities that the 2.5 mm stylus can’t reach will not be defined in the milledbridge, but have to be adjusted after delivery from the Nobel Biocare production facility. For the Procera® ImplantBridge Titanium, the model and framework may still be sent to the production facility for scanning.

3. Scan the Model and Framework – cont.• The scans are fused together in the Procera®

Software and the resulting scanned Procera®

Implant Bridge is viewed

• View, approve and send the Procera® ImplantBridge file to the Procera® production facility

Straumann® is a registered trademark of Straumann Group.Ankylos® is a trademark of Dentsply Friadent Group.Astra Tech® is a trademark of AstraZeneca Group.Camlog® is a trademark of Camlog Biotechnologies Group.

3i® is a registered trademark of Biomet Group. Lifecore® Biomedical Restore is a registered trademark of Lifecore Biomedical Group.Zimmer® Dental Taper-Lock is a registered trademark of Zimmer Group.Sterngold® Implamed is a registered trademark of Sterngold Group.

Procera® Implant Bridge for other implant systemsProcera® Implant Bridge is available at implant level for Straumann® Regular Neck 4.8 mm and Wide Neck 6.5 mm implants.

Procera® implant Bridge is also available at abutment level for Ankylos® Implant System 3.5, 4.5, 5.5, 7.0 mm, Astra Tech® Implant System 4.5ST, 5.0ST mm and Camlog® Implant System 3.3, 3.8, 4.3, 5.0, 6.0 mm, byusing Multi-unit Abutments designed for each implant system.

Note: Follow the normal laboratory procedure for Procera® Implant Bridge, by using Abutment Replicas Multi-Unit in the model.

Page 35: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

35Product illustrations are not to scale

permanent implant restorations

Sing

le Too

th A

butm

ent

1. Model• An implant level impression is received with an

implant replica.

• Confirm the position of the implant levelimpression coping and implant replica assemblyin the impression.

• Pour and fabricate a soft tissue master model.

• Attach the Single Tooth Abutment to the implantreplica and secure it with a lab screw.

Prosthetic AlternativesProcera® Crown (see page 8)Standard C&B restoration (see below)

Single Tooth Abutment NobelReplace™

Titanium

Indications • Single tooth implant restoration with limited interdental space• Cement-retained

2. Restoration• Use an aluminum oxide grinding instrument to

modify the Single Tooth Abutment. Use a protectionanalog to protect the margin of the abutment. Amatrix/ template can be fabricated using a patternresin to aid the restorative dentist in properly placing the modified abutment in the mouth.

• Fabricate the restoration framework using standardC&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Internal Connection

Page 36: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

36 Product illustrations are not to scale

Narro

w Pro

file Ab

utmen

t No

belA

ctive™

Intern

al

permanent implant restorations

1. Model• An implant level impression is received with an

implant replica.

• Confirm the position of the implant level impressioncoping and implant replica assembly in the impression.

• Pour and fabricate a soft tissue master model.

• Attach the Narrow Profile Abutment to the implant replica and secure it with a lab screwBrånemark System®.

Prosthetic AlternativesProcera® Crown (see page 8)Standard C&B restoration (see below)

2. Restoration• Use an aluminum oxide grinding instrument

to modify the Narrow Profile Abutment. Use aprotection analog to protect the margin of theabutment. A matrix/ template can be fabricatedusing a pattern resin to aid the restorative dentistin properly placing the modified abutment in the mouth.

• Fabricate the restoration framework using standardC&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Narrow Profile Abutment NobelActive™ InternalTitanium

Indications • For implant restorations with limited interdental space• Cement-retained

Page 37: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

1a. Model with the Abutment Replica Easy Abutment™

(Applicable if the Easy Abutment™ has not been modified.)• The impression is received with the embedded Easy

Abutment™ Impression Coping and an Abutment Replica Easy Abutment™.

• Confirm the placement of the replica in theimpression coping, ensuring correct alignment of the three grooves.

• Pour and fabricate a soft tissue master model.

1b. Model with stone dies(Applicable if the Easy Abutment™ has been modified.)• A standard C&B impression is received.

• Pour the model in hard die stone or epoxy.

• Pin and die the model using standard laboratorytechniques.

Easy Abutment™

Titanium

Indications • Single tooth or multiple unit implant restorations

ideal for posterior restorations• Cement-retained

External Connection Internal Connection

37Product illustrations are not to scale

permanent implant restorations

Easy Ab

utmen

t™

Page 38: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

38 Product illustrations are not to scale

Easy Ab

utmen

t™

permanent implant restorations

Prosthetic AlternativesProcera® Crown (see page 8)Procera® Bridge (see page 12)Ceramic Coping Easy Abutment™ (see below)Plastic Coping Easy Abutment™ (see below)

2a. Restoration with Ceramic Coping Easy Abutment™

• Complete the restoration with NobelRondo™ ceramicand return to dentist for final delivery.

Ceramic CopingEasy Abutment™

Engaging

2b. Restoration with Plastic Coping Easy Abutment™

• Place the plastic coping on the abutment. For single tooth restorations, use the engaging plasticcoping. For multiple unit restorations, use the non-engaging plastic coping.

• Wax the framework around the plastic coping or stone die.

• Fabricate the restoration framework using standard C&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Page 39: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

39Product illustrations are not to scale

permanent implant restorations

Go

ldA

dap

t Eng

agin

g

The GoldAdapt Engaging engages the implant’s antirotational feature and can be used in two ways:

• Custom abutment for cement-retained restorations, see below• Single screw-retained restoration, see page 41

1. Model• An implant level impression is received with an

implant replica

• Confirm the position of the implant levelimpression coping and implant replica assembly inthe impression

• Pour and fabricate a soft tissue master model

• Attach the GoldAdapt to the implant replica andsecure with a lab screw

GoldAdapt EngagingGold base/pre-attached waxing sleeve

Indications • Screw-retained single tooth• Cement-retained single tooth and multiple unit restorations• Screw access hole location through occlusal surface of posterior

teeth or cingulum of anterior teeth without angle correction• Limited interocclusal and/or interdental space

Internal ConnectionExternal Connection

Prosthetic AlternativesProcera® Crown (see page 8)Standard C&B restoration

Cement retained restorations

Page 40: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

40 Product illustrations are not to scale

Go

ldA

dap

t Eng

agin

g

permanent implant restorations

2. Restoration• Reduce the height of the plastic sleeve as desired.

For best result, use a double-sided diamond disk.

• Wax-up the framework around the GoldAdapt sothat it ensures optimum esthetics and retention ofthe restoration. If the restoration will be splinted,check abutments for parallelism.

• Fabricate the final abutment using standard C&Btechniques.

• Finalize abutment with finishing stones and rubberwheels, and return to the dentist. See picture forfinalized abutment.

Note: If the abutment will be scanned to fabricate aProcera® Crown, make sure the contours and finish line are smooth.

Alloy Recommendations

GoldAdapt:Melting range: 1400–1490°C/2550–2720°F.Coefficient of thermal expansion: 12 µm/m*°K.

Recommended casting alloys:

Conventional gold alloys: High gold content (min 75% Au + Pt metal) alloys, standard ISO 1562 type 4.Soldering in the range of 800–890°C/1472–1634°F.

Ceramic bonding alloys: High gold content (min 75% Au) alloys, standard ISO/DIS 9693, NIOM type A.Soldering in the range of 800–890°C/1472–1634°F.

Page 41: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

41Product illustrations are not to scale

Go

ldA

dap

t Eng

agin

g

permanent implant restorations

1. Model• An implant level impression is received with an

implant replica.

• Confirm the position of the implant impressioncoping and implant replica assembly in the impression.

• Pour and fabricate a soft tissue master model.

• Attach the GoldAdapt to the implant replica andsecure with a lab screw.

Single screw-retained restoration

2. Restoration

• Reduce the height of the plastic sleeve as desired.For best result use a double-sided diamond disk.

• Wax the framework around the GoldAdapt.

Note: The gold base is made from a non-oxidizingalloy. Cracking of porcelain may occur if it is applieddirectly to the gold base. Make sure the wax covers thegold base with a minimum wax thickness of 0.5 mm. A reduction to 0.3 mm can be made after casting.

Page 42: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

42

2. Restoration – cont.

• Fabricate the restoration framework using standardC&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Alloy Recommendations

GoldAdapt:Melting range: 1400–1490°C/2550–2720°F.Coefficient of thermal expansion: 12 µm/m*°K.

Recommended casting alloys:

Conventional gold alloys: High gold content (min 75% Au +Pt metal) alloys, standard ISO 1562 type 4.Soldering in the range of 800–890°C/1472–1634°F.

Ceramic bonding alloys: High gold content (min 75% Au) alloys, standard ISO/DIS 9693, NIOM type A.Soldering in the range of 800–890°C/1472–1634°F.

Product illustrations are not to scale

Go

ldA

dap

t Eng

agin

g

permanent implant restorations

Page 43: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

43Product illustrations are not to scale

Go

ldA

dap

t No

n-En

gag

ing

permanent implant restorations

1. Model• An implant level impression is received with

implant replicas.

• Confirm the position of the impression coping andimplant replica assembly in the impression.

• Pour and fabricate a soft tissue master model.

• Attach the GoldAdapt to the implant replica andsecure with a lab screw.

2. Restoration• Reduce the height of the plastic sleeve as desired.

For best result use a double-sided diamond disk.

• Wax the framework around the GoldAdapt.

Note: The gold base is made from a non-oxidizingalloy. Cracking of porcelain may occur if it is applieddirectly to the gold base. Make sure the wax covers thegold base with a minimum wax thickness of 0.5 mm. A reduction to 0.3 mm can be made after casting.

GoldAdapt Non-EngagingGold base/pre-attached waxing sleeve

Indications • Multiple unit implant restoration• Limited interocclusal space• Screw access hole location through occlusal surface of posterior

teeth or cingulum of anterior teeth without angle correction• Implants with less than 40° overall divergence to allow path

of insertion• Screw-retained

Internal ConnectionExternal Connection

Page 44: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

44 Product illustrations are not to scale

Go

ldA

dap

t No

n-En

gag

ing

permanent implant restorations

Restoration cont.• Fabricate the restoration framework using

standard C&B techniques.

• Complete the restoration with ceramic and returnto the dentist for final delivery.

Alloy Recommendations

GoldAdapt:Melting range: 1400–1490°C/2550–2720°F.Coefficient of thermal expansion: 12 µm/m*°K.

Recommended casting alloys:

Conventional gold alloys: High gold content (min 75% Au +Pt metal) alloys, standard ISO 1562 type 4.Soldering in the range of 800–890°C/1472–1634°F.

Ceramic bonding alloys: High gold content (min 75% Au) alloys, standard ISO/DIS 9693, NIOM type A.Soldering in the range of 800–890°C/1472–1634°F.

Page 45: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

45Product illustrations are not to scale

Go

ld A

butm

ent B

ar/Go

ld C

op

ing

Bar

overdenture restorations

2. Restoration• Attach a bar to the abutments/copings with wax

or resin material. Tighten replicas to the goldabutments/copings and embed them into solderinginvestment.

• Solder the bar to the gold abutments/copings

• Block out the bar and prepare a wax try-in of thetooth set-up. Send to the dentist for try-in.

1. Model• An implant level or abutment level impression is

received with replicas.

• Confirm the position of the impression coping andreplica assembly in the impression.

• Fabricate a master model.

• Attach the gold abutments/copings to the replicasand tighten them using lab screws or guide pins.Make an occlusal rim, incorporate the goldabutments/copings and send to the dentist for arecord of the jaw relationship.

Gold Abutment Bar/Gold Coping Bar Indications • Fully edentulous arch• Extensive bone or soft tissue loss• Compromised patient manual dexterity• Necessity for soft tissue support• Phonetic concerns

A bar-retained overdenture is a conventional acrylic denture retained byattachments to an implant-supported cast. The denture can be either tissuesupported or implant supported.

Internal ConnectionExternal Connection

Gold Abutment Bar Implant Level

Gold Coping Bar Multi-unit

Page 46: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

46 Product illustrations are not to scale

Go

ld A

butm

ent B

ar/Go

ld C

op

ing

Bar

overdenture restorations

Gold Abutment Bar/Gold Coping Bar:Soldering in the range of 800–890°C/1472–1634°F.

3. Concluding Procedure• Block underneath the bar and around the gold

abutments/copings. Process the attachments intothe overdenture.

• Complete and finish denture using standarddenture procedures. Return to the dentist for finaldelivery.

Page 47: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

47Product illustrations are not to scale

Ball A

butm

ent Titan

ium

overdenture restorations

2. Restoration• Prepare a wax try-in of the tooth set-up.

1. Model• An abutment level impression is received with

Abutment Replicas Ball Abutment.

• Confirm the placement of the replicas in theimpression.

• Pour the model in hard die stone or epoxy.

• Block the abutment replicas and prepare anocclusal rim. Send to the dentist for a record ofthe jaw relationship.

Ball Abutment TitaniumIndications • Fully edentulous arch• Extensive bone or soft tissue loss• Compromised patient manual dexterity• Necessity for soft tissue support• Phonetic concerns• Implant placed too far posterior to connect with a bar• Allows for misangulation up to 30° between implants

A Ball Abutment overdenture is a tissue supported conventional overdenture retained by abutments, which arethreaded directly into the implants.

External Connection Internal Connection

Page 48: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

48

Screwdriver/Activator for Gold Cap Ball Abutment

Product illustrations are not to scale

Ball A

butm

ent Titan

ium

overdenture restorations

• Process the denture using standard techniques.

Note: If the dentist will process a Gold Cap, use the redprocessing cap and process in the same manner.

• Complete and finish the denture using standarddenture procedures. Return to the dentist for finaldelivery.

3. Concluding Procedure• Place the Gold Caps Ball Abutment onto the replicas,

block out the inside of the gold cap with a rubberseparator or silicone to prevent acrylic from enteringduring processing. If additional retention is necessary,adjust by turning the lamellae retention insert clockwise(increasing) or counterclockwise (decreasing) usingthe Screwdriver/Activator.

Note: Do not turn more than one turn.

• Position the Gold Caps so that they are parallel toeach other in a horizontal/vertical plane. Use clearacrylic to prevent tipping of Gold Cap. Block outfrom the bottom of the cap to the ridge.

How to exchange the Gold Cap Ball Abutment Insert1. The insert is exchanged by using 29163

Screwdriver/Activator. Inserting and rotating theScrewdriver/Activator counter-clockwise removesthe lamellae insert.

2. Put the new insert on the Screwdriver/Activator.

3. Screw in and activate the insert.

Page 49: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

49

appendices

Product illustrations are not to scale

Terms yo

u need

to kn

ow

– Glo

ssary

Terms you need to know – Glossary

Abutment – A component screwed to the top of the implant thatserves as a support and retention for the temporary or finalprosthetic restoration.

Immediate Function™ – Temporary or permanent prostheticsolution delivered immediately at surgery. The procedure isclinically documented.

Immediate loading – Immediate occlusal loading.

External connection – External hexagonal implant/abutmentinterface.

Cement retained restorations – A restoration cemented over the abutment.

Abutment Screw – A screw that secures the abutment to theimplant and torqued to a final position. In laboratories a Labscrew is used to avoid damaging the abutment screw.

Abutment level impression – An impression taken on the abutment,using conventional techniques or using an abutment levelimpression coping. Used to transfer the position of the abutmentfrom the patient’s mouth to a master model.

Page 50: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

appendices

Implant level impression – An impression taken on the implant.Used to transfer the position of the implant from the patient’smouth to a master model.

Internal connection – Internal tri-channel implant/abutmentinterface.

Impression Coping – A device used to register the position ofthe implant or abutment when taking an impression. It stays inthe impression or must be removed from the oral cavity andrepositioned in the impression.

Manual Torque Wrench Prosthetic – A torque wrench used to tighten abutments and restorations to the desired torquemeasurement.

Permanent abutments – Abutments designed to remain permanently in the patient’s mouth.

Procera® Software – A software from Nobel Biocare used to orderthe unique, on-demand and customized Procera® abutments,laminates, crowns and bridges. Used also together with theNobelGuide™ Concept.

50

Terms yo

u need

to kn

ow

– Glo

ssary

Page 51: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

51Product illustrations are not to scale

appendices

Terms yo

u need

to kn

ow

– Glo

ssary

2

3

1

Replica (abutment or implant) – A replica of the abutment or implant attached to the impression coping after taking animpression to help make an accurate model.

Prosthetic Screw (1) – A screw that secures the restoration tothe abutment and torqued to a final position. In laboratories aLab screw is used to avoid damaging the abutment screw.

Screwdriver Machine/Manual Unigrip™ (2) – A screwdriverused to retain screws for abutments and restorations.

Screw-retained restorations (3) – A restoration retained byscrews through the crown and threads into the abutment.

Temporary Abutments and copings – Abutments and copingsused for making temporary restorations. They are removed priorto securing the final restoration.

Try-in Abutments – Used to help select the proper size andshape abutment for the patient. Made of plastic, theseabutments can be reused.

Page 52: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

52

appendices

Imp

lant/A

butm

ent In

terface Diam

eter

Product illustrations are not to scale

NP ∅ 3.5 mminterface

RP ∅ 4.1 mminterface

WP ∅ 5.1 mminterface

External Connection

Internal Connection

Internal Connection NobelPerfect®

NP ∅ 3.5 mminterface

RP ∅ 4.3 mminterface

WP ∅ 5.0 mminterface

6.0 ∅ 6.0 mminterface

NP ∅ 4.3 mminterface

RP ∅ 5.0 mminterface

WP ∅ 5.75 mminterface

NobelDirect® Posterior

RP ∅ 4.3 mm

WP ∅ 5.0 mm

6.0 ∅ 6.0 mm

NP ∅ 3.5 mm

RP ∅ 3.9 mm

Interface Diameter

Implant/Abutment Interface Diameter

Our products are organized according to a “platformconcept”, which facilitates treatment planning.

Narrow Platform (NP) for situations in which thereis limited interdental space or a narrow crest.

Regular Platform (RP) for cases ranging from singleanterior tooth loss to complete edentulism.

Wide Platform (WP) where additional loading canbe expected or whenever a wider diameterimplant/abutment is considered preferable.

6.0 Platform (6.0) where additional loading can be expected or whenever an even wider diameterimplant/abutment is considered preferable.

External ConnectionBrånemark System® Mk III Groovy*NobelSpeedy™ Groovy**Brånemark System® Mk III*Brånemark System® Mk IVBrånemark System® Zygoma TiUnite®

Brånemark System® Zygoma

Internal ConnectionNobelReplace™ Tapered GroovyNobelReplace™ Straight GroovyNobelSpeedy™ ReplaceReplace® Select TaperedReplace® Select Straight

Internal ConnectionNobelPerfect®

NobelPerfect® Groovy

One-Piece ImplantsNobelDirect® Posterior***

NobelActive™

*For RP ∅ 3.75 and RP ∅ 4 implants, use RP prosthetic components.** For WP ∅ 5 and WP ∅ 6 implants, use WP prosthetic components.***Use prosthetic components for Snappy Abutment™.

NobelActive™

Page 53: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

53

appendices

Ab

utmen

t Selection

Product illustrations are not to scale

Abutment SelectionIf the final restoration is to meet the esthetic and functional demands of the dentist and patient, selecting the properabutment is crucial. In some cases, the dentist makes the abutment selection and sends an abutment levelimpression to the laboratory. However in many cases, the dentist takes an impression at implant level to facilitatethe abutment choice.

When selecting abutments, there are a few things to look at,such as:

Platform/SystemDifferent brands have different platform systems. The platform ofthe abutment must be correspondent to the implant platform.For further information see page 49.

Tissue/Cuff HeightTo determine the right cuff height, measure the soft tissue deptharound the implant replica. The cuff height can be chosen eitherdepending on the importance of esthetics or hygiene.

Vertical SpaceIn addition to the height of the selected abutment, an additional1.5 to 2 mm of space must be available over the prostheticcomponents to allow for casting and/or veneering material.

Interdental SpaceThe available interdental space and desired emergence profilealso help determine the choice of abutment and collar height.

AngulationThe angulation of each implant will determine which abutmentcan be used, straight or angled, or whether a customized abutmentis needed.

Type of RestorationSome of the abutments in the Nobel Biocare Implant System arespecifically designed for either single tooth or multiple-unitrestorations.

Page 54: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

54

Ab

utmen

t Selection

Product illustrations are not to scale

appendices

Cement-retainedCement-retained restorations on implants follow the same basicprotocol as tooth-supported crowns and fixed partial denturerestorations. While the abutments are screw-retained in to theimplants, the restoration is cemented over the abutments. The use of temporary cement is recommended for ease of retrievability.

Note: Do not use temporary cement for Procera® Crowns or Procera®

Bridge Zirconia and Alumina.

Screw-retainedA screw-retained restoration is retained by screws that enterthrough the occlusal or cingulum area of the restoration. Thescrew passes through the crown and threads into the abutment.The restoration is retrievable by the dentist.

Try-in AbutmentsIn order to facilitate the abutment selection there are now plasticTry-in Abutments available with internal or external connections.These are intended to be placed into an implant (intra-orally) orimplant replica (dental laboratory) to aid making the selection ofan appropriate shape and size abutment.

The Try-in Abutments are available for Snappy Abutments™,straight and angled Esthetic Abutments and angled Multi-unitAbutments. A soft tissue measuring tool is included along withthe Try-in Abutments.

The Try-in Abutments are reusable and indicated for partially orfully edentulous cases.

Page 55: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

55Product illustrations are not to scale

appendices

Mo

del Tech

niq

ues

Impression Coping Closed Tray Multi-unit

NobelDirect® Groovy One-Piece Implant

Impression Coping Implant Level ClosedTray, NobelReplace™

Model Techniques

Identifying Type of ImpressionSeveral impression techniques are used in ImplantDentistry; Conventional C&B impression, or a “Closed”or “Open” Tray Impression made at either implant orabutment level.

The first step is to identify the technique andimpression type sent to the lab. The second step is todetermine the required product(s) needed before theimpression can be poured.

Implant Level Impression Transfers the position of the implant from the patient’smouth to a master model so that an appropriateabutment can be selected for the case.

Abutment Level Impression An abutment is preselected by the dentist, placed andtorqued onto the implant. An appropriate abutmentlevel impression coping is used to transfer the positionof the abutment from the patient’s mouth to a model.

Conventional C&B ImpressionThis technique is used when a one-piece implant isplaced or an abutment for a cement-retained crown or bridge is chosen and modified by the dentist.

The abutment is torqued on the implant and preparedlike a natural tooth. An impression is taken of theabutment(s) capturing the abutment margin (retractioncord may be used). The impression is treated as astandard C&B impression.

Closed Tray Technique

• The laboratory receives both the impression and theimpression coping.

• Tighten a corresponding implant or abutment replicaonto the impression coping and reposition thisassembly back into the impression.

• Pour the impression with soft tissue material and harddie stone.

Page 56: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

56 Product illustrations are not to scale

Mo

del Tech

niq

ues

appendicesExternal

& InternalConnection

ExternalConnection

InternalConnection

InternalConnection

NobelPerfect®

Platformshift

Impression Coping Bar Closed Tray Multi-unit

Implant Replica

Abutment Replica Multi-unit

Impression Coping BarImplant Level

Impression Coping Closed Tray Multi-unit

Impression Coping Implant Level Closed Tray Plastic

Product List

Impression Coping Implant Level Closed Tray Low Profile

Impression Coping Implant Level Closed Tray

Product List NobelActive™

Page 57: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

3.5 4.3 5.0 6.0

57Product illustrations are not to scale

appendices

Mo

del Tech

niq

ues

Impression Copings

Abutment Replicas

Abutment Replica Ball Abutment

Ball AbutmentImpression

Impression Coping Snappy Abutment™

Impression with Impression Copings Snappy Abutment™ and

Abutment Replicas.

Snappy Abutment™ Impression

The Impression Coping Snappy Abutment™ isembedded in the impression. The impression maybe recording a Snappy Abutment™ tightened to animplant or a NobelDirect® Posterior Implant. Theimpression coping has an integrated plastic fingerthat fits into the abutment replica. The AbutmentReplica Snappy Abutment™ is needed and theimpression is poured out using soft tissue material and hard die stone.

Easy Abutment™ ImpressionThe Impression Coping Easy Abutment™ isembedded in the impression. The Abutment ReplicaEasy Abutment™ is required.

Note: If the dentist has modified the Easy Abutment™, a standard C&B impression is taken and poured outwith die stone.

Ball Abutment ImpressionA direct impression of the Ball Abutment Titanium is received. An Abutment Replica Ball Abutment isrequired.

Page 58: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

58

Mo

del Tech

niq

ues

appendices

Product illustrations are not to scale

ExternalConnection

InternalConnection

Open Tray TechniqueAlso known as the “pick-up” method this techniqueis suitable for cases with many implants where thelack of parallelism would make tray removal difficultusing the closed tray technique. A limitation may bewhere there is limited vertical space.

• The laboratory receives the impression with theimpression coping inside.

Note: Do not remove the impression coping from theimpression.

• Tighten a corresponding implant replica orabutment replica to the coping using the guide pin.

Note: Keep a firm grip on the replica while tighteningthe guide pin so that no forces are transferred to theimpression coping and dislocating it from its referencepoint. Do not over tighten the guide pin.

• Pour the impression with soft tissue material andhard die stone.

Impression Coping ImplantLevel Open Tray

Implant Replica

Impression Coping OpenTray Multi-unit

Abutment Replica Multi-unit

Product List NobelActive™

Page 59: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

59Product illustrations are not to scale

appendices

Mo

del Tech

niq

ues

Soft Tissue Application Soft tissue material is used to simulate the clinicalsoft tissue contours.

The material is a self-hardening silicone and isapplied around each coping/replica assembly beforethe impression is poured with stone.

The flexible material facilitates placement of various abutments onto a sub-gingivally placed replica. It also makes it easier to build out the emergenceprofile of the restoration without damaging thetissue contour.

The soft tissue material can also be removed fromthe stone model to confirm that the abutments arefully seated on the replicas.

Note: With full arch C&B cases the soft tissue can beapplied along the entire ridge. For tissue supported overdentures soft tissue material should only be appliedaround the implant/abutment replicas.

Model with soft tissue material roundimplant replicas

Page 60: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

Curvy™ EstheticAbutment

60

Prosth

etic Instrum

ents &

Screwd

river Selection

Guid

e

appendices

Product illustrations are not to scale

Multi-unit Implant Level

Multi-unit Multi-unit Multi-unit Angled

ImplantLevel

Procera® EstheticAbutment

Easy Abutment™

SnappyAbutment™

Gold Abutment Bar

Straight and Angled Esthetic Abutment Titanium

Procera® AbutmentTitanium, Zirconia

Procera® Abutment NobelPerfect® Titanium

Abutment NobelPerfect®

Straight, Angled Titanium

TemporaryAbutment

Angled Multi-unit

GoldAdapt™

Abutments

Guide Pins

Prosthetic Screws Lab Screws

Brånemark System®

NobelReplace™

Multi-unit NP/RP

Multi-unit NP/RP/WP

Multi-unit Abutment Screwdrivers (internal hexagon)

Manual 25 mm

Machine 21 mm

Prosthetic InstrumentsHandle for Machine Instruments

Screwdriver/Activator for Gold Cap Ball Abutment

Manual Torque Wrench Adapter Prosthetic

Handle for Protection Analog

Screwdrivers Unigrip™

Manual 20 mm

Manual 28 mm

Manual 36 mm

Machine 20 mm

Machine 25 mm

Machine 30 mm

Machine 35 mm

Recommended for lab use:

Manual 36 mm

Machine 35 mm

Screwdriver Selection Guide

Prosthetic Instruments & Screwdriver Selection Guide

Page 61: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

61Product illustrations are not to scale

Torq

ue Guid

e

appendices

Torque Guide

Plastic Temporary AbutmentPlastic Temporary CopingHealing AbutmentHealing Cap

Prosthetic Screws for final restorationsTitanium Temporary Coping

Ball Abutment17° Multi-unit Abutment30° Multi-unit Abutment

All other Abutments

Manual

Page 62: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

62

Alphabetical order

Description Article Page

A

AbutmentsBall Abutment Titanium

Ball Abutment Titanium Brånemark System® RP 1 mm . . . . . . . . 31905 . . . . . . . . . . . . . . 48Ball Abutment Titanium Brånemark System® RP 3 mm . . . . . . . . 31906 . . . . . . . . . . . . . . 48Ball Abutment Titanium Brånemark System® RP 5 mm . . . . . . . . 31907 . . . . . . . . . . . . . . 48Ball Abutment Titanium NobRpl NP 1 mm. . . . . . . . . . . . . . . . . 31908 . . . . . . . . . . . . . . 48Ball Abutment Titanium NobRpl NP 2 mm. . . . . . . . . . . . . . . . . 31909 . . . . . . . . . . . . . . 48Ball Abutment Titanium NobRpl NP 3 mm. . . . . . . . . . . . . . . . . 31910 . . . . . . . . . . . . . . 48Ball Abutment Titanium NobRpl RP 1 mm . . . . . . . . . . . . . . . . . 31911 . . . . . . . . . . . . . . 48Ball Abutment Titanium NobRpl RP 2 mm . . . . . . . . . . . . . . . . . 31912 . . . . . . . . . . . . . . 48Ball Abutment Titanium NobRpl RP 3 mm . . . . . . . . . . . . . . . . . 31913 . . . . . . . . . . . . . . 48

Curvy™ Esthetic AbutmentCurvy™ Esthetic Abutment NobRpl NP 2 mm . . . . . . . . . . . . . . . 34588 . . . . . . . . . . . . . . 26Curvy™ Esthetic Abutment NobRpl RP 2 mm . . . . . . . . . . . . . . . 34589 . . . . . . . . . . . . . . 26Curvy™ Esthetic Abutment NobRpl WP 2 mm. . . . . . . . . . . . . . . 34590 . . . . . . . . . . . . . . 2615° Curvy™ Esthetic Abut NobRpl NP 2 mm. . . . . . . . . . . . . . . . 34591 . . . . . . . . . . . . . . 2615° Curvy™ Esthetic Abut NobRpl RP 2 mm . . . . . . . . . . . . . . . . 34592 . . . . . . . . . . . . . . 2615° Curvy™ Esthetic Abut NobRpl WP 2 mm. . . . . . . . . . . . . . . . 34593 . . . . . . . . . . . . . . 26Curvy™ Esthetic Abutment Bmk Syst NP 3 mm. . . . . . . . . . . . . . 34594 . . . . . . . . . . . . . . 26Curvy™ Esthetic Abutment Bmk Syst RP 3 mm . . . . . . . . . . . . . . 34605 . . . . . . . . . . . . . . 26Curvy™ Esthetic Abutment Bmk Syst WP 3 mm . . . . . . . . . . . . . 34606 . . . . . . . . . . . . . . 2615° Curvy™ Esthetic Abut Bmk Syst NP 3 mm. . . . . . . . . . . . . . . 34607 . . . . . . . . . . . . . . 2615° Curvy™ Esthetic Abut Bmk Syst RP 3 mm . . . . . . . . . . . . . . . 34608 . . . . . . . . . . . . . . 2615° Curvy™ Esthetic Abut Bmk Syst WP 3 mm . . . . . . . . . . . . . . 34609 . . . . . . . . . . . . . . 26

Easy Abutment™

Easy Abutment™ NobRpl NP 0.75 mm . . . . . . . . . . . . . . . . . . . . 29468 . . . . . . . . . . . . . . 38Easy Abutment™ NobRpl NP 1.5 mm . . . . . . . . . . . . . . . . . . . . . 29469 . . . . . . . . . . . . . . 38Easy Abutment™ NobRpl RP 0.5 mm . . . . . . . . . . . . . . . . . . . . . 29470 . . . . . . . . . . . . . . 38Easy Abutment™ NobRpl RP 1.5 mm . . . . . . . . . . . . . . . . . . . . . 29471 . . . . . . . . . . . . . . 38Easy Abutment™ NobRpl WP 0.5 mm . . . . . . . . . . . . . . . . . . . . . 29472 . . . . . . . . . . . . . . 38Easy Abutment™ NobRpl WP 1.5 mm . . . . . . . . . . . . . . . . . . . . . 29473 . . . . . . . . . . . . . . 38Easy Abutment™ NobRpl 6.0 mm . . . . . . . . . . . . . . . . . . . . . . . 29988 . . . . . . . . . . . . . . 38Easy Abutment™ Brånemark System® NP 1 mm . . . . . . . . . . . . . 30672 . . . . . . . . . . . . . . 38Easy Abutment™ Brånemark System® NP 2 mm . . . . . . . . . . . . . 30673 . . . . . . . . . . . . . . 38Easy Abutment™ Brånemark System® RP 1 mm. . . . . . . . . . . . . . 30674 . . . . . . . . . . . . . . 38Easy Abutment™ Brånemark System® RP 2 mm. . . . . . . . . . . . . . 30705 . . . . . . . . . . . . . . 38Easy Abutment™ Brånemark System® WP 1 mm . . . . . . . . . . . . . 30706 . . . . . . . . . . . . . . 38Easy Abutment™ Brånemark System® WP 2 mm . . . . . . . . . . . . . 30707 . . . . . . . . . . . . . . 38

Esthetic AbutmentEsthetic Abutment NobRpl NP 1 mm . . . . . . . . . . . . . . . . . . . . . 32372 . . . . . . . . . . . . . . 26Esthetic Abutment NobRpl NP 3 mm . . . . . . . . . . . . . . . . . . . . . 32376 . . . . . . . . . . . . . . 26Esthetic Abutment NobRpl RP 1 mm . . . . . . . . . . . . . . . . . . . . . 32373 . . . . . . . . . . . . . . 26Esthetic Abutment NobRpl RP 3 mm . . . . . . . . . . . . . . . . . . . . . 32377 . . . . . . . . . . . . . . 26Esthetic Abutment NobRpl WP 0.5 mm . . . . . . . . . . . . . . . . . . . 32374 . . . . . . . . . . . . . . 26Esthetic Abutment NobRpl WP 3 mm. . . . . . . . . . . . . . . . . . . . . 32378 . . . . . . . . . . . . . . 26Esthetic Abutment NobRpl 6.0/0.5 mm . . . . . . . . . . . . . . . . . . 32375 . . . . . . . . . . . . . . 26Esthetic Abutment Bmk Syst NP 2 mm. . . . . . . . . . . . . . . . . . . . 32396 . . . . . . . . . . . . . . 26Esthetic Abutment Bmk Syst RP 1 mm . . . . . . . . . . . . . . . . . . . . 32397 . . . . . . . . . . . . . . 26Esthetic Abutment Bmk Syst RP 3 mm . . . . . . . . . . . . . . . . . . . . 32399 . . . . . . . . . . . . . . 26Esthetic Abutment Bmk Syst WP 1 mm . . . . . . . . . . . . . . . . . . . 32398 . . . . . . . . . . . . . . 26Esthetic Abut NobelActive™ Int NP 1.5 mm . . . . . . . . . . . . . . . . 34194 . . . . . . . . . . . . . . 26Esthetic Abut NobelActive™ Int NP 3 mm . . . . . . . . . . . . . . . . . . 34195 . . . . . . . . . . . . . . 26Esthetic Abut NobelActive™ Int RP 1.5 mm. . . . . . . . . . . . . . . . . 34198 . . . . . . . . . . . . . . 26Esthetic Abutment NobelActive™ Int RP 3 mm . . . . . . . . . . . . . . 34199 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl NP 1 mm. . . . . . . . . . . . . . . . . . 32380 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl NP 3 mm. . . . . . . . . . . . . . . . . . 32384 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl RP 1 mm . . . . . . . . . . . . . . . . . . 32381 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl RP 3 mm . . . . . . . . . . . . . . . . . . 32385 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl WP 0.5 mm . . . . . . . . . . . . . . . . 32382 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl WP 3 mm . . . . . . . . . . . . . . . . . 32386 . . . . . . . . . . . . . . 2615° Esthetic Abutment NobRpl 6.0/0.5 mm . . . . . . . . . . . . . . . 32383 . . . . . . . . . . . . . . 2615º Esthetic Abutment Bmk Syst NP 2 mm . . . . . . . . . . . . . . . . 32400 . . . . . . . . . . . . . . 2615º Esthetic Abutment Bmk Syst RP 1 mm. . . . . . . . . . . . . . . . . 32401 . . . . . . . . . . . . . . 2615º Esthetic Abutment Bmk Syst RP 3 mm. . . . . . . . . . . . . . . . . 32403 . . . . . . . . . . . . . . 2615º Esthetic Abutment Bmk Syst WP 1 mm . . . . . . . . . . . . . . . . 32402 . . . . . . . . . . . . . . 2615° Esthetic Ab NobelActive™ Int NP 1.5 mm. . . . . . . . . . . . . . . 34196 . . . . . . . . . . . . . . 2615° Esthetic Ab NobelActive™ Int NP 3 mm . . . . . . . . . . . . . . . . 34197 . . . . . . . . . . . . . . 2615° Esth Abut NobelActive™ Int RP 1.5 mm . . . . . . . . . . . . . . . . 34200 . . . . . . . . . . . . . . 2615° Esth Abutment NobelActive™ Int RP 3 mm. . . . . . . . . . . . . . 34201 . . . . . . . . . . . . . . 26

GoldAdapt AbutmentGoldAdapt Engaging Brånemark System® NP . . . . . . . . . . . . . . . 29004 . . . . . . . . . . . 40,42GoldAdapt Engaging Brånemark System® RP . . . . . . . . . . . . . . . 29008 . . . . . . . . . . . 40,42GoldAdapt Engaging Brånemark System® WP. . . . . . . . . . . . . . . 29012 . . . . . . . . . . . 40,42GoldAdapt Non-Engaging Brånemark System® NP . . . . . . . . . . . 29005 . . . . . . . . . . . . . . 44GoldAdapt Non-Engaging Brånemark System® RP . . . . . . . . . . . 29009 . . . . . . . . . . . . . . 44GoldAdapt Non-Engaging Brånemark System® WP . . . . . . . . . . . 29013 . . . . . . . . . . . . . . 44GoldAdapt Engaging NobRpl NP . . . . . . . . . . . . . . . . . . . . . . . . 29006 . . . . . . . . . . . 40,42GoldAdapt Engaging NobRpl RP . . . . . . . . . . . . . . . . . . . . . . . . 29010 . . . . . . . . . . . 40,42GoldAdapt Engaging NobRpl WP . . . . . . . . . . . . . . . . . . . . . . . . 29014 . . . . . . . . . . . 40,42GoldAdapt Engaging NobRpl 6.0 . . . . . . . . . . . . . . . . . . . . . . . 29989 . . . . . . . . . . . 40,42GoldAdapt Non-Engaging NobRpl NP . . . . . . . . . . . . . . . . . . . . 29007 . . . . . . . . . . . . . . 44GoldAdapt Non-Engaging NobRpl RP . . . . . . . . . . . . . . . . . . . . 29011 . . . . . . . . . . . . . . 44GoldAdapt Non-Engaging NobRpl WP . . . . . . . . . . . . . . . . . . . . 29015 . . . . . . . . . . . . . . 44

GoldAdapt Non-Engaging NobRpl 6.0 . . . . . . . . . . . . . . . . . . . 29990 . . . . . . . . . . . . . . 44

Gold Abutment BarGold Abutment Bar Implant Level NobRpl NP . . . . . . . . . . . . . . 29061 . . . . . . . . . . . . . . 46Gold Abutment Bar Implant Level NobRpl RP . . . . . . . . . . . . . . 29062 . . . . . . . . . . . . . . 46Gold Abutment Bar Implant Level Bmk Syst RP . . . . . . . . . . . . . 29068 . . . . . . . . . . . . . . 46

Multi-unit AbutmentMulti-unit Abutment Brånemark System® NP 1 mm . . . . . . . . . 29176 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® NP 2 mm . . . . . . . . . 29177 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® NP 3 mm . . . . . . . . . 29178 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® RP 1 mm . . . . . . . . . . 29179 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® RP 2 mm . . . . . . . . . . 29180 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® RP 3 mm . . . . . . . . . . 29181 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® RP 4 mm . . . . . . . . . . 29182 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® RP 5 mm . . . . . . . . . . 29183 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® WP 1 mm . . . . . . . . . 29184 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® WP 2 mm . . . . . . . . . 29185 . . . . . . . . . . . . . . 28Multi-unit Abutment Brånemark System® WP 3 mm . . . . . . . . . 29186 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl NP 1 mm . . . . . . . . . . . . . . . . . . 29196 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl NP 2 mm . . . . . . . . . . . . . . . . . . . 29197 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl NP 3 mm . . . . . . . . . . . . . . . . . . . 29198 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl RP 1 mm . . . . . . . . . . . . . . . . . . . 29199 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl RP 2 mm . . . . . . . . . . . . . . . . . . . 29200 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl RP 3 mm . . . . . . . . . . . . . . . . . . . 29201 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl RP 4 mm . . . . . . . . . . . . . . . . . . . 29202 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl RP 5 mm . . . . . . . . . . . . . . . . . . . 29203 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl WP 1 mm . . . . . . . . . . . . . . . . . . 29204 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl WP 2 mm . . . . . . . . . . . . . . . . . . 29205 . . . . . . . . . . . . . . 28Multi-unit Abutment NobRpl WP 3 mm . . . . . . . . . . . . . . . . . . 29206 . . . . . . . . . . . . . . 28Multi-unit Abut NobelActive™ Int NP 1.5 mm. . . . . . . . . . . . . . . 34186 . . . . . . . . . . . . . . 28Multi-unit Abut NobelActive™ Int NP 2.5 mm. . . . . . . . . . . . . . . 34187 . . . . . . . . . . . . . . 28Multi-unit Abut NobelActive™ Int NP 3.5 mm. . . . . . . . . . . . . . . 34595 . . . . . . . . . . . . . . 28Multi-unit Abut NobelActive™ Int RP 1.5 mm . . . . . . . . . . . . . . . 34190 . . . . . . . . . . . . . . 28Multi-unit Abut NobelActive™ Int RP 2.5 mm . . . . . . . . . . . . . . . 34191 . . . . . . . . . . . . . . 28Multi-unit Abut NobelActive™ Int RP 3.5 mm . . . . . . . . . . . . . . . 34596 . . . . . . . . . . . . . . 28Multi-unit Abutment for Astra Tech® 3.5 . . . . . . . . . . . . . . . . . . 33543 . . . . . . . . . . . . . . 36Multi-unit Abutment for Astra Tech® 4.0 . . . . . . . . . . . . . . . . . . 33544 . . . . . . . . . . . . . . 36Multi-unit Abutment for Astra Tech® 4.5/5.0 . . . . . . . . . . . . . . . 33545 . . . . . . . . . . . . . . 36Multi-unit Abutment for Camlog® 3.3 . . . . . . . . . . . . . . . . . . . . 33556 . . . . . . . . . . . . . . 36Multi-unit Abutment for Camlog® 3.8 . . . . . . . . . . . . . . . . . . . . 33557 . . . . . . . . . . . . . . 36Multi-unit Abutment for Camlog® 4.3 . . . . . . . . . . . . . . . . . . . . 33558 . . . . . . . . . . . . . . 36Multi-unit Abutment for Camlog® 5.0/6.0. . . . . . . . . . . . . . . . . 33559 . . . . . . . . . . . . . . 36Multi-unit Abutment for Ankylos® . . . . . . . . . . . . . . . . . . . . . . . 33572 . . . . . . . . . . . . . . 36

Multi-unit Angled Abutment 17º Multi-unit Abutment Brånemark System® NP 2 mm. . . . . . . 29187 . . . . . . . . . . . . . . 2817º Multi-unit Abutment Brånemark System® NP 3 mm. . . . . . . 29188 . . . . . . . . . . . . . . 2817º Multi-unit Abutment Brånemark System® RP 2 mm . . . . . . . 29189 . . . . . . . . . . . . . . 2817º Multi-unit Abutment Brånemark System® RP 3 mm . . . . . . . 29190 . . . . . . . . . . . . . . 2817º Multi-unit Abutment Brånemark System® RP 4 mm . . . . . . . 29191 . . . . . . . . . . . . . . 2830º Multi-unit Abutment Brånemark System® RP 4 mm . . . . . . . 29192 . . . . . . . . . . . . . . 2830º Multi-unit Abutment Brånemark System® RP 5 mm . . . . . . . 29193 . . . . . . . . . . . . . . 2817º Multi-unit Abutment NobRpl NP 2 mm . . . . . . . . . . . . . . . . 29235 . . . . . . . . . . . . . . 2817º Multi-unit Abutment NobRpl NP 3 mm . . . . . . . . . . . . . . . . 29236 . . . . . . . . . . . . . . 2817º Multi-unit Abutment NobRpl RP 2 mm . . . . . . . . . . . . . . . . 29237 . . . . . . . . . . . . . . 2817º Multi-unit Abutment NobRpl RP 3 mm . . . . . . . . . . . . . . . . 29238 . . . . . . . . . . . . . . 2817º Multi-unit Abutment NobRpl RP 4 mm . . . . . . . . . . . . . . . . 29239 . . . . . . . . . . . . . . 2830º Multi-unit Abutment NobRpl RP 4 mm . . . . . . . . . . . . . . . . 29240 . . . . . . . . . . . . . . 2830º Multi-unit Abutment NobRpl RP 5 mm . . . . . . . . . . . . . . . . 29241 . . . . . . . . . . . . . . 2817° Multi-u Ab NobelActive™ Int NP 2.5 mm . . . . . . . . . . . . . . . 34188 . . . . . . . . . . . . . . 2817° Multi-u Ab NobelActive™ Int NP 3.5 mm . . . . . . . . . . . . . . . 34189 . . . . . . . . . . . . . . 2830° Multi-u Ab NobelActive™ Int NP 3.5 mm . . . . . . . . . . . . . . . 34367 . . . . . . . . . . . . . . 2830° Multi-u Ab NobelActive™ Int NP 4.5 mm . . . . . . . . . . . . . . . 34368 . . . . . . . . . . . . . . 2817° Multi-u Ab NobelActive™ Int RP 2.5 mm . . . . . . . . . . . . . . . 34192 . . . . . . . . . . . . . . 2817° Multi-u Ab NobelActive™ Int RP 3.5 mm . . . . . . . . . . . . . . . 34193 . . . . . . . . . . . . . . 2830° Multi-u Ab NobelActive™ Int RP 3.5 mm . . . . . . . . . . . . . . . 34369 . . . . . . . . . . . . . . 2830° Multi-u Ab NobelActive™ Int RP 4.5 mm . . . . . . . . . . . . . . . 34370 . . . . . . . . . . . . . . 28

Narrow Profile AbutmentNarrow Profile Ab NobelActive™ Int NP 7 mm . . . . . . . . . . . . . . 34371 . . . . . . . . . . . . . . 38Narrow Profile Ab NobelActive™ Int NP 9 mm . . . . . . . . . . . . . . 34372 . . . . . . . . . . . . . . 38Narrow Profile Ab NobelActive™ Int RP 7 mm. . . . . . . . . . . . . . . 34597 . . . . . . . . . . . . . . 38Narrow Profile Ab NobelActive™ Int RP 9 mm. . . . . . . . . . . . . . . 34598 . . . . . . . . . . . . . . 38Procera® Abutment

Procera® Abutment Ti Brånemark System® NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti Brånemark System® NP Wax-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti Brånemark System® RP Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti Brånemark System® WP Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ NP wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ RP wax-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ WP wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelReplace™ 6.0 wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti Octagon 4.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Astra Tech® 3.5 ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Prod

uct Referen

ce Guid

e

index

Page 63: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

63

index

Prod

uct Referen

ce Guid

e

Procera® Abutment Titanium for Astra Tech® 3.5 ST Wax-up. . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Astra Tech® 4.0 ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Astra Tech® 4.0 ST Wax-up. . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Astra Tech® 4.5/5.0 ST . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Astra Tech® 4.5/5.0 ST Wax-up . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 3.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 3.3 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 3.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 3.8 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 4.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 4.3 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Titanium for Camlog® 5.0/6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelActive™ Int NP. . . . . . . . . . . . . . . . . 18374 . . . . . . . . . . . . . . 19Procera® Abutment Ti NobelActive™ Int RP . . . . . . . . . . . . . . . . . 18376 . . . . . . . . . . . . . . 19Procera® Ab Ti NobelActive™ Int NP Wax-up . . . . . . . . . . . . . . . . 18375 . . . . . . . . . . . . . . 19Procera® Ab Ti NobelActive™ Int RP Wax-up . . . . . . . . . . . . . . . . 18377 . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Astra Tech® 3.5 ST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Astra Tech® 3.5 ST Wax-up . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Astra Tech® 4.0 ST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Astra Tech® 4.0 ST Wax-up . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Astra Tech® 4.5/5.0 ST . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Astra Tech® 4.5/5.0 ST Wax-up . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 3.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 3.3 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 3.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 3.8 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 4.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 4.3 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 5.0/6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zirconia for Camlog® 5.0/6.0 Wax-up . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Brånemark System® NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Brånemark System® NP Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Brånemark System® RP Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Brånemark System® WP Wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ NP wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ RP wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ WP wax-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelReplace™ 6.0 wax-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Octagon 4.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr Octagon 4.8 Wax-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelActive™ Int NP . . . . . . . . . . . . . . . . 18249 . . . . . . . . . . . . . . 19Procera® Ab Zr NobelActive™ Int NP Wax-up . . . . . . . . . . . . . . . 18260 . . . . . . . . . . . . . . 19Procera® Abutment Zr NobelActive™ Int RP. . . . . . . . . . . . . . . . . 18261 . . . . . . . . . . . . . . 19Procera® Ab Zr NobelActive™ Int RP Wax-up . . . . . . . . . . . . . . . . 18263 . . . . . . . . . . . . . . 19

Procera® Abutment Zirconia PSProcera® Abutment Zirconia Bmk Syst NP PS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Procera® Abutment Zirconia Bmk Syst RP PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Procera® Esthetic Abutment Selection KitProcera® Esthetic Abutment Brånemark System® NP # 1 . . . . . . . 33754 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® NP # 2 . . . . . . . 33755 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® NP # 3 . . . . . . . 33756 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® NP # 4 . . . . . . . 33757 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 5 . . . . . . . 33758 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 6 . . . . . . . 33759 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 7 . . . . . . . 33760 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 8 . . . . . . . 33761 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 9 . . . . . . . 33762 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 10 . . . . . . 33763 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 11 . . . . . . 33764 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® RP # 12 . . . . . . 33765 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 13. . . . . . 33766 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 14. . . . . . 33767 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 15. . . . . . 33768 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 16. . . . . . 33769 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 17. . . . . . 33770 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 18. . . . . . 33771 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 19. . . . . . 33772 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Brånemark System® WP # 20. . . . . . 33773 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ NP # 1 . . . . . . . . . . 33774 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ NP # 2 . . . . . . . . . . 33775 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ NP # 3 . . . . . . . . . . 33776 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ NP # 4 . . . . . . . . . . 33777 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 5. . . . . . . . . . . 33778 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 6. . . . . . . . . . . 33779 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 7. . . . . . . . . . . 33780 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 8. . . . . . . . . . . 33781 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 9. . . . . . . . . . . 33782 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 10. . . . . . . . . . 33783 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 11. . . . . . . . . . 33784 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ RP # 12. . . . . . . . . . 33785 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 13 . . . . . . . . . 33786 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 14 . . . . . . . . . 33787 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 15 . . . . . . . . . 33788 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 16 . . . . . . . . . 33789 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 17 . . . . . . . . . 33790 . . . . . . . . . . . . . . 18

Procera® Esthetic Abutment NobelReplace™ WP # 18 . . . . . . . . . 33791 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 19 . . . . . . . . . 33792 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ WP # 20 . . . . . . . . . 33793 . . . . . . . . . . . . . . 18

Procera® Esthetic Abutment Platform Shifting™Procera® Esthetic Abutment NobelReplace™ NP # 1 . . . . . . . . . . 34535 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ NP # 2 . . . . . . . . . . 34536 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ NP # 3 . . . . . . . . . . 34537 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ NP # 4 . . . . . . . . . . 34538 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 5. . . . . . . . . . . 34539 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 6. . . . . . . . . . . 34540 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 7. . . . . . . . . . . 34541 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 8. . . . . . . . . . . 34542 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 9. . . . . . . . . . . 34543 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 10. . . . . . . . . . 34544 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 11. . . . . . . . . . 34545 . . . . . . . . . . . . . . 22Procera® Esthetic Abutment NobelReplace™ RP # 12. . . . . . . . . . 34546 . . . . . . . . . . . . . . 22

Procera® Esthetic Abutment NobelActive™ InternalProcera® Esth Abut NobelActive™ Int NP #1 . . . . . . . . . . . . . . . . 34118 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int NP #2 . . . . . . . . . . . . . . . . 34119 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int NP #3 . . . . . . . . . . . . . . . . 34120 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int NP #4 . . . . . . . . . . . . . . . . 34121 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int RP #5. . . . . . . . . . . . . . . . . 34122 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int RP #6. . . . . . . . . . . . . . . . . 34123 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int RP #7. . . . . . . . . . . . . . . . . 34124 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int RP #8. . . . . . . . . . . . . . . . . 34175 . . . . . . . . . . . . . . 18Procera® Esth Abut NobelActive™ Int RP #9. . . . . . . . . . . . . . . . . 34176 . . . . . . . . . . . . . . 18Procera® Est Abut NobelActive™ Int RP #10. . . . . . . . . . . . . . . . . 34177 . . . . . . . . . . . . . . 18Procera® Est Abut NobelActive™ Int RP #11. . . . . . . . . . . . . . . . . 34178 . . . . . . . . . . . . . . 18Procera® Est Abut NobelActive™ Int RP #12. . . . . . . . . . . . . . . . . 34179 . . . . . . . . . . . . . . 18

Single Tooth AbutmentSingle Tooth Abutment NobRpl NP . . . . . . . . . . . . . . . . . . . . . . 29476 . . . . . . . . . . . . . . 37

Snappy Abutment™

Snappy Abutment™ NobRpl NP 0.75 mm . . . . . . . . . . . . . . . . . 32334 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl RP 0.5 mm . . . . . . . . . . . . . . . . . . 32335 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl WP 0.5 mm. . . . . . . . . . . . . . . . . . 32336 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl 6.0/0.5 mm . . . . . . . . . . . . . . . . . 32337 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl NP 1.5 mm . . . . . . . . . . . . . . . . . . 32338 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl RP 1.5 mm . . . . . . . . . . . . . . . . . . 32339 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl WP 1.5 mm. . . . . . . . . . . . . . . . . . 32340 . . . . . . . . . . . . . . 24Snappy Abutment™ NobRpl 6.0/1.5 mm . . . . . . . . . . . . . . . . . 32341 . . . . . . . . . . . . . . 24Snappy Abutment™ Bmk Syst NP 1 mm . . . . . . . . . . . . . . . . . . 32342 . . . . . . . . . . . . . . 24Snappy Abutment™ Bmk Syst RP 1 mm . . . . . . . . . . . . . . . . . . 32343 . . . . . . . . . . . . . . 24Snappy Abutment™ Bmk Syst WP 1 mm . . . . . . . . . . . . . . . . . . 32344 . . . . . . . . . . . . . . 24Snappy Abutment™ Bmk Syst NP 2 mm . . . . . . . . . . . . . . . . . . 32345 . . . . . . . . . . . . . . 24Snappy Abutment™ Bmk Syst RP 2 mm . . . . . . . . . . . . . . . . . . 32346 . . . . . . . . . . . . . . 24Snappy Abutment™ Bmk Syst WP 2 mm . . . . . . . . . . . . . . . . . . 32347 . . . . . . . . . . . . . . 24Snappy Abutment™ NobelActive™ Int RP 1.5 mm . . . . . . . . . . . 34206 . . . . . . . . . . . . . . 24Snappy Abutment™ NobelActive™ Int RP 3 mm. . . . . . . . . . . . . 34207 . . . . . . . . . . . . . . 24

Abutment ScrewScrew Ceramic Abutment Brånemark System® NP . . . . . . . . . . . 31171. . . . . . . . . . . . 18,19Screw Ceramic Abutment Brånemark System® RP. . . . . . . . . . . . 28815. . . . . . . . . . . . 18,19Screw Ceramic Abutment NobRpl RP/WP 6.0 . . . . . . . . . . . . . . . 28816. . . . . . . . . . . . 18,19Screw Ceramic Abutment NobRpl NP . . . . . . . . . . . . . . . . . . . . 28837. . . . . . . . . . . . 18,19Screw Ceramic Abutment Brånemark System® WP . . . . . . . . . . . 28844. . . . . . . . . . . . 18,19Screw Multi-unit Angled Abutment Brånemark System® NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29194 . . . . . . . . . . . . . . 28Screw Multi-unit Angled Abutment Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29195 . . . . . . . . . . . . . . 28Screw Multi-unit Angled Abutment NobRpl NP . . . . . . . . . . . . . 29242 . . . . . . . . . . . . . . 28Screw Multi-unit Angled Abutment NobRpl RP . . . . . . . . . . . . . 29243 . . . . . . . . . . . . . . 28Abutment Screw Brånemark System® NP . . . . . . . . . . . . . . . . . . 29282. . . . . . . . . . . . 19,26Abutment Screw Brånemark System® RP . . . . . . . . . . . . . . . . . . 29283. . . . . . . . . . . . 19,26Abutment Screw Brånemark System® WP . . . . . . . . . . . . . . . . . . 29284. . . . . . . . . . . . 19,26Abutment Screw NobRpl NP . . . . . . . . . . . . . . . . . . . . . . . . . . . 29474. . . . . . . . . . . . 19,26Abutment Screw NobRpl RP/WP/6.0 . . . . . . . . . . . . . . . . . . . . . . 29475. . . . . . . . . . . . 19,26Abutment Screw Octagon Ti . . . . . . . . . . . . . . . . . . . . . . . . . . 31984 . . . . . . . . . . . . . . 19Abutment Screw Zirconia for Astra Tech® 3.5 . . . . . . . . . . . . . . 33546 . . . . . . . . . . . . . . 19Abutment Screw Zirconia for Astra Tech® 4.0/4.5/5.0 . . . . . . . . 33547 . . . . . . . . . . . . . . 19Abutment Screw Titanium for Astra Tech® 3.5. . . . . . . . . . . . . . 33548 . . . . . . . . . . . . . . 19Abutment Screw Titanium for Astra Tech® 4.0/4.5/5.0 . . . . . . . 33549 . . . . . . . . . . . . . . 19Abutment Screw Zirconia for Camlog® 3.3/3.8 . . . . . . . . . . . . . 33561 . . . . . . . . . . . . . . 19Abutment Screw Zirconia for Camlog® 5.0/6.0 . . . . . . . . . . . . . 33562 . . . . . . . . . . . . . . 19Abutment Screw Titanium for Camlog® 3.3/3.8/4.3 . . . . . . . . . 33563 . . . . . . . . . . . . . . 19Abutment Screw Titanium for Camlog® 5.0/6.0 . . . . . . . . . . . . 33564 . . . . . . . . . . . . . . 19Abutment Screw PS RP/NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34553 . . . . . . . . . . . . . . 22Abutment Screw PS WP/RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34554 . . . . . . . . . . . . . . 22

Easy Abutment™ ScrewScrew Easy Abutment™ NobRpl NP 0.75 mm . . . . . . . . . . . . . . 29839 . . . . . . . . . . . . . . 38Screw Easy Abutment™ NobRpl NP 1.5 mm . . . . . . . . . . . . . . . 29840 . . . . . . . . . . . . . . 38Screw Easy Abutment™ NobRpl RP/WP 6.0/0.5 mm . . . . . . . . . . 29841 . . . . . . . . . . . . . . 38Screw Easy Abutment™ NobRpl RP/WP 1.5 mm. . . . . . . . . . . . . . 28786 . . . . . . . . . . . . . . 38Screw Easy Abutment™ Brånemark System® NP 1 mm . . . . . . . . 30663 . . . . . . . . . . . . . . 38Screw Easy Abutment™ Brånemark System® NP 2 mm . . . . . . . . 30664 . . . . . . . . . . . . . . 38Screw Easy Abutment™ Brånemark System® RP 1 mm. . . . . . . . . 30725 . . . . . . . . . . . . . . 38Screw Easy Abutment™ Brånemark System® RP 2 mm. . . . . . . . . 30726 . . . . . . . . . . . . . . 38Screw Easy Abutment™ Brånemark System® WP 1 mm . . . . . . . . 30727 . . . . . . . . . . . . . . 38Screw Easy Abutment™ Brånemark System® WP 2 mm . . . . . . . . 30728 . . . . . . . . . . . . . . 38

Page 64: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

64

index

Prod

uct Referen

ce Guid

e

Abutment Replica Ball Abutment

Abutment Replica Ball Abutment NP/RP . . . . . . . . . . . . . . . . . . . 29114 . . . . . . . . . . . 48,58

Easy Abutment™

Abutment Replica Easy Abutment™ NP . . . . . . . . . . . . . . . . . . . . 30042 . . . . . . . . . . . 38,58Abutment Replica Easy Abutment™ RP . . . . . . . . . . . . . . . . . . . . 29504 . . . . . . . . . . . 38,58Abutment Replica Easy Abutment™ WP. . . . . . . . . . . . . . . . . . . . 29505 . . . . . . . . . . . 38,58Abutment Replica Easy Abutment™

∅ 6 mm/Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . 29996 . . . . . . . . . . . 38,58

Multi-unit AbutmentAbutment Replica Multi-unit 5/pkg . . . . . . . . . . . . . . . . . . . . . . 29110 . . . . . . . . . . . 28,59Abutment Replica Multi-unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 31161 . . . . . . . . . . . 28,59Abutment Replica Multi-unit Brånemark System® WP . . . . . . . . . 31162 . . . . . . . . . . . 28,59

Snappy Abutment™

Abutment Replica Snappy Abutment™ NP . . . . . . . . . . . . . . . . . 32368 . . . . . . . . . . . 24,58Abutment Replica Snappy Abutment™ RP. . . . . . . . . . . . . . . . . . 32369 . . . . . . . . . . . 24,58Abutment Replica Snappy Abutment™ NobRpl WP . . . . . . . . . . . 32370 . . . . . . . . . . . 24,58Abutment Replica Snappy Abutment™

NobRpl 6.0/Bmk Syst WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32371 . . . . . . . . . . . 24,58

CCeramic Coping Easy Abutment™

Ceramic Coping Easy Abutment™ Engaging NP . . . . . . . . . . . . . 30037 . . . . . . . . . . . . . . 38Ceramic Coping Easy Abutment™ Engaging RP . . . . . . . . . . . . . 29481 . . . . . . . . . . . . . . 38Ceramic Coping Easy Abutment™ Engaging WP . . . . . . . . . . . . . 29482 . . . . . . . . . . . . . . 38Ceramic Coping Easy Abutment™ Engaging ∅ 6 mm/Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . 30671 . . . . . . . . . . . . . . 38Ceramic Coping NobelPerfect® NP, alumina. . . . . . . . . . . . . . . . 30749 . . . . . . . . . . . . . . 30Ceramic Coping NobelPerfect® RP, alumina . . . . . . . . . . . . . . . . 30750 . . . . . . . . . . . . . . 30Ceramic Coping NobelPerfect® WP, alumina . . . . . . . . . . . . . . . 30751 . . . . . . . . . . . . . . 3010° Ceramic Coping NobelPerfect® NP, alumina . . . . . . . . . . . . 31275 . . . . . . . . . . . . . . 3010° Ceramic Coping NobelPerfect® RP, alumina. . . . . . . . . . . . . 31276 . . . . . . . . . . . . . . 3010° Ceramic Coping NobelPerfect® WP, alumina . . . . . . . . . . . . 31277 . . . . . . . . . . . . . . 30

GGold Cap

Ball AbutmentGold Cap Ball Abutment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29025 . . . . . . . . . . . . . . 48Gold Cap Ball Abutment Insert . . . . . . . . . . . . . . . . . . . . . . . . . 33855 . . . . . . . . . . . . . . 48

Gold CopingMulti-unit Abutment

Gold Coping Multi-unit 5/pkg. . . . . . . . . . . . . . . . . . . . . . . . . . 29042 . . . . . . . . . . . . . . 28Gold Coping Multi-unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29043 . . . . . . . . . . . . . . 28Gold Coping Multi-unit Bmk Syst WP. . . . . . . . . . . . . . . . . . . . . 29044 . . . . . . . . . . . . . . 28Gold Coping Bar Multi-unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . 29045 . . . . . . . . . . . . . . 46

Guide PinImplant level

Guide Pin Implant Level Brånemark System® NP 20 mm . . . . . . 31147 . . . . 19,29,32,35,46Guide Pin Implant Level Brånemark System® RP 20 mm. . . . . . . 31148 . . . . 19,29,32,35,46Guide Pin Implant Level Brånemark System® RP 30 mm. . . . . . . 31149 . . . . 19,29,32,35,46Guide Pin Implant Level Brånemark System® WP 20 mm . . . . . . 31150 . . . . 19,29,32,35,46Guide Pin Implant Level NobRpl NP 20 mm. . . . . . . . . . . . . . . . 31151 . . . . 19,29,32,35,46Guide Pin Implant Level NobRpl RP/WP 20 mm . . . . . . . . . . . . . 31152 . . . . 19,29,32,35,46Guide Pin Implant Level NobRpl RP/WP 30 mm . . . . . . . . . . . . . 31153 . . . . 19,29,32,35,46

Multi-unit AbutmentGuide Pin Multi-unit 10 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . 31154 . . . . . . . . . . . . . . 29Guide Pin Multi-unit 10 mm 5/pkg . . . . . . . . . . . . . . . . . . . . . . 29102 . . . . . . . . . . . . . . 29Guide Pin Multi-unit Brånemark System® WP 10 mm . . . . . . . . . 31156 . . . . . . . . . . . . . . 29Guide Pin Multi-unit 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . 31155 . . . . . . . . . . . . . . 29Guide Pin Multi-unit 20 mm 5/pkg . . . . . . . . . . . . . . . . . . . . . . 29103 . . . . . . . . . . . . . . 29

HHandle for Protection Analogs . . . . . . . . . . . . . . . . . . . . . . . . . . . 29122 . . . . . . . . . . . . . . 61

IImplant Replica

Implant Replica Brånemark System® RP 5/pkg . . . . . . . . . . . . . . 29108. . . . . . . . . . . . 57,59Implant Replica NobRpl NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29498. . . . . . . . . . . . 57,59Implant Replica NobRpl NP 20/pkg . . . . . . . . . . . . . . . . . . . . . . 29499. . . . . . . . . . . . 57,59Implant Replica NobRpl RP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29500. . . . . . . . . . . . 57,59Implant Replica NobRpl RP 20/pkg . . . . . . . . . . . . . . . . . . . . . . 29501. . . . . . . . . . . . 57,59Implant Replica NobRpl WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29502. . . . . . . . . . . . 57,59Implant Replica NobRpl WP 20/pkg . . . . . . . . . . . . . . . . . . . . . . 29503. . . . . . . . . . . . 57,59Implant Replica NobRpl 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . 29995. . . . . . . . . . . . 57,59Implant Replica Brånemark System® NP . . . . . . . . . . . . . . . . . . . 31158. . . . . . . . . . . . 57,59Implant Replica Brånemark System® RP . . . . . . . . . . . . . . . . . . . 31159. . . . . . . . . . . . 57,59Implant Replica Brånemark System® WP . . . . . . . . . . . . . . . . . . . 31160. . . . . . . . . . . . 57,59Implant Replica PS RP/NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34556. . . . . . . . . . . . 22,57Implant Replica PS WP/RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34557. . . . . . . . . . . . 22,57Implant Replica NobelPerfect® NP . . . . . . . . . . . . . . . . . . . . . . . 29606. . . . . . . . . . . . 30,57Implant Replica NobelPerfect® RP. . . . . . . . . . . . . . . . . . . . . . . . 30997. . . . . . . . . . . . 30,57Implant Replica NobelPerfect® WP . . . . . . . . . . . . . . . . . . . . . . . 29608. . . . . . . . . . . . 30,57Implant replica NobelActive™ Internal NP . . . . . . . . . . . . . . . . . . . . . 34243. . . . . . . . . . . . . 57,59Implant replica NobelActive™ Internal RP. . . . . . . . . . . . . . . . . . . . . . 34244. . . . . . . . . . . . . 57,59

Impression Coping Easy Abutment™

Impression Cap Easy Abutment™ NobRpl 6.0 . . . . . . . . . . . . . . 28812. . . . . . . . . . . . 38,58Impression Cap Easy Abutment™ RP . . . . . . . . . . . . . . . . . . . . . . 29496. . . . . . . . . . . . 38,58Impression Cap Easy Abutment™ WP . . . . . . . . . . . . . . . . . . . . . 29497. . . . . . . . . . . . 38,58Impression Cap Easy Abutment™ NP. . . . . . . . . . . . . . . . . . . . . . 30041. . . . . . . . . . . . 38,58Impression Cap Easy Abutment™

Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30713. . . . . . . . . . . . 38,58

Multi-unit AbutmentImpression Coping Closed Tray Multi-unit . . . . . . . . . . . . . . . . . . . 29090 . . . . . . . . . . . . 28,57Impression Coping Closed Tray Multi-unit Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . 29092 . . . . . . . . . . . . 28,57Impression Coping Open Tray Multi-unit . . . . . . . . . . . . . . . . . . . . 29089 . . . . . . . . . . . . 28,57Impression Coping Open Tray Multi-unit Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . 29091 . . . . . . . . . . . . 28,57Impression Coping Bar Closed Tray Multi-unit . . . . . . . . . . . . . . . . 29093 . . . . . . . . . . . . 46,57

Snappy Abutment™

Impression Coping Snappy Abutment™ NP . . . . . . . . . . . . . . . . . . . 32352 . . . . . . . . . . . . 24,58Impression Coping Snappy Abutment™ RP . . . . . . . . . . . . . . . . . . . 32353 . . . . . . . . . . . . 24,58Impression Coping Snappy Abutment™ NobRpl WP . . . . . . . . . . . . 32354 . . . . . . . . . . . . 24,58Impression Coping Snappy Abutment™

NobRpl 6.0/Bmk Syst WP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32355 . . . . . . . . . . . . 24,58

Bar Implant LevelImpression Coping Bar Brånemark System® RP . . . . . . . . . . . . . . . . 29076 . . . . . . . . . . . . 46,57Impression Coping Bar NobRpl NP . . . . . . . . . . . . . . . . . . . . . . . . . 29087 . . . . . . . . . . . . 46,57Impression Coping Bar NobRpl RP . . . . . . . . . . . . . . . . . . . . . . . . . 29088 . . . . . . . . . . . . 46,57

Closed Tray Implant LevelImpression Coping Closed Tray Brånemark System® RP. . . . . . . . . . 29073 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Bmk Syst NP ∅ 3.5 mm . . . . . . . . 33462 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Bmk Syst NP ∅ 4.5 mm . . . . . . . . 33463 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Bmk Syst RP ∅ 4 mm . . . . . . . . . . 33464 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Bmk Syst RP ∅ 5 mm . . . . . . . . . . 29073 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Bmk Syst WP ∅ 5 mm . . . . . . . . . . 33465 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Bmk Syst WP ∅ 6 mm . . . . . . . . . . 29075 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl NP ∅ 3.5 mm. . . . . . . . . . 33537 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl NP ∅ 4.5 mm. . . . . . . . . . 33470 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl RP ∅ 4.3 mm . . . . . . . . . . 33540 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl RP ∅ 5.3 mm . . . . . . . . . . 33471 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl WP ∅ 5 mm . . . . . . . . . . . 33472 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl WP ∅ 6 mm . . . . . . . . . . . 29494 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl 6.0 ∅ 6 mm . . . . . . . . . . 30040 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray NobRpl 6.0 ∅ 7 mm . . . . . . . . . . 33473 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl NP ∅ 3.5 mm . 33538 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl NP ∅ 4.5 mm . 33474 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl RP ∅ 4.3 mm . 33541 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl RP ∅ 5.3 mm . 33475 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl WP ∅ 5 mm. . 33476 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl WP ∅ 6 mm. . 32178 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl 6.0 ∅ 6 mm . 32179 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Low Profile NobRpl 6.0 ∅ 7 mm . 33477 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl NP ∅ 3.5 mm . . . . 32425 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl NP ∅ 4.5 mm . . . . 33478 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl RP ∅ 4.3 mm. . . . . 33542 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl RP ∅ 5.3 mm. . . . . 33479 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl WP ∅ 5 mm. . . . . . 33480 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl WP ∅ 6 mm. . . . . . 32427 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl 6.0 ∅ 6 mm . . . . . 32428 . . . . . . . . . . . . . . . 57Impression Coping Closed Tray Plastic NobRpl 6.0 ∅ 7 mm . . . . . 33481 . . . . . . . . . . . . . . . 57Impression Coping PS RP/NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34547 . . . . . . . . . . . . 22,57Impression Coping PS WP/RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34548 . . . . . . . . . . . . 22,57Impression Coping NobelPerfect® NP, Closed Tray. . . . . . . . . . . . . 29603 . . . . . . . . . . . . 30,57Impression Coping NobelPerfect® RP, Closed Tray . . . . . . . . . . . . . 30999 . . . . . . . . . . . . 30,57Impression Coping NobelPerfect® WP, Closed Tray . . . . . . . . . . . . 29605 . . . . . . . . . . . . 30,57Im Cop Cl Tr NobelActive™ Int NP ∅ 3.6 × 13 mm . . . . . . . . . . . . . 34230 . . . . . . . . . . . . . . . 57Im Cop Cl Tr NobelActive™ Int NP ∅ 5 × 13 mm . . . . . . . . . . . . . . 34231 . . . . . . . . . . . . . . . 57 Im Cop Cl Tr NobelActive™ Int RP ∅ 3.6 × 13 mm . . . . . . . . . . . . . 34232 . . . . . . . . . . . . . . . 57Im Cop Cl Tr NobelActive™ Int RP ∅ 3.6 × 9 mm . . . . . . . . . . . . . . 34233 . . . . . . . . . . . . . . . 57Im Cop Cl Tr NobelActive™ Int RP ∅ 5 × 13 mm. . . . . . . . . . . . . . . 34234 . . . . . . . . . . . . . . . 57Im Cop Cl Tr NobelActive™ Int RP ∅ 5 × 9 mm. . . . . . . . . . . . . . . . 34235 . . . . . . . . . . . . . . . 57Im Cop Cl Tr NobelActive™ Int RP ∅ 6 × 13 mm. . . . . . . . . . . . . . . 34236 . . . . . . . . . . . . . . . 57Im Cop Cl Tr NobelActive™ Int RP ∅ 6 × 9 mm. . . . . . . . . . . . . . . . 34237 . . . . . . . . . . . . . . . 57Impr Cop Bridge Cl Tr NobelActive™ Int NP. . . . . . . . . . . . . . . . . . . 34679 . . . . . . . . . . . . . . . 57Impr Cop Bridge Cl Tr NobelActive™ Int RP . . . . . . . . . . . . . . . . . . . 34680 . . . . . . . . . . . . . . . 57

Page 65: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

65

index

Prod

uct Referen

ce Guid

e

Open Tray Implant LevelImpression Coping Open Tray Bmk Syst NP ∅ 3.5 mm . . . . . . . . . 33458 . . . . . . . . . . . . . . . 59Impression Coping Open Tray Bmk Syst NP ∅ 4.5 mm . . . . . . . . . 33459 . . . . . . . . . . . . . . . 59Impression Coping Open Tray Bmk Syst RP ∅ 4 mm . . . . . . . . . . . 33460 . . . . . . . . . . . . . . . 59Impression Coping Open Tray Bmk Syst RP ∅ 5 mm . . . . . . . . . . . 29072 . . . . . . . . . . . . . . . 59Impression Coping Open Tray Bmk Syst WP ∅ 5 mm. . . . . . . . . . . 33461 . . . . . . . . . . . . . . . 59Impression Coping Open Tray Bmk Syst WP ∅ 6 mm. . . . . . . . . . . 29074 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl NP ∅ 3.5 mm . . . . . . . . . . 29485 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl NP ∅ 4.5 mm . . . . . . . . . . 33466 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl RP ∅ 4.3 mm. . . . . . . . . . . 33539 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl RP ∅ 5.3 mm. . . . . . . . . . . 33467 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl WP ∅ 5 mm. . . . . . . . . . . . 33468 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl WP ∅ 6 mm. . . . . . . . . . . . 29493 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl 6.0 ∅ 6 mm . . . . . . . . . . . 30039 . . . . . . . . . . . . . . . 59Impression Coping Open Tray NobRpl 6.0 ∅ 7 mm . . . . . . . . . . . 33469 . . . . . . . . . . . . . . . 59Impr Cop Open Tr NobelActive™ Int NP ∅ 3.6 mm . . . . . . . . . . . . 34238 . . . . . . . . . . . . . . . 59Impr Cop Open Tray NobelActive™ Int NP ∅ 5 mm . . . . . . . . . . . . 34239 . . . . . . . . . . . . . . . 59Impr Cop Open Tr NobelActive™ Int RP ∅ 3.6 mm. . . . . . . . . . . . . 34240 . . . . . . . . . . . . . . . 59Impr Cop Open Tray NobelActive™ Int RP ∅ 5 mm. . . . . . . . . . . . . 34241 . . . . . . . . . . . . . . . 59Impr Cop Open Tray NobelActive™ Int RP ∅ 6 mm. . . . . . . . . . . . . 34242 . . . . . . . . . . . . . . . 59

KKit

Procera®

Procera® Abutment 3D CADD Kit . . . . . . . . . . . . . . . . . . . . . . . 31967 . . . . . . . . . . . . . . 19Procera® Abutment Wax-up Kit . . . . . . . . . . . . . . . . . . . . . . . . . 31217 . . . . . . . . . . . . . . 19Procera® Abutment Wax-up Kit for Astra Tech® . . . . . . . . . . . . . 33550 . . . . . . . . . . . . . . 19Procera® Abutment 3D CADD Kit for Astra Tech® . . . . . . . . . . . 33552 . . . . . . . . . . . . . . 19Procera® Abutment Wax-up Kit for Camlog® . . . . . . . . . . . . . . . 33565 . . . . . . . . . . . . . . 19Procera® Abutment 3D CADD Kit for Camlog® . . . . . . . . . . . . . 33566 . . . . . . . . . . . . . . 19Procera® Abutment 3D CADD kit Octagon . . . . . . . . . . . . . . . . 31567 . . . . . . . . . . . . . . 19Procera® Esthetic Abutment Brånemark System® Selection Kit . . 33435 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment Bmk Syst Selection Kit Box. . . . . . . 33483 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ Selection Kit. . . . . . 33316 . . . . . . . . . . . . . . 18Procera® Esthetic Abutment NobelReplace™ Selection Kit Box . . 33484 . . . . . . . . . . . . . . 18Procera® Est Ab NobelActive™ Int Sel Kit . . . . . . . . . . . . . . . . . . . . . . . 34184. . . . . . . . . . . . . . . . 18Procera® E Ab NobelActive™ Int Sel KitBox . . . . . . . . . . . . . . . . . . . . . 34185. . . . . . . . . . . . . . . . 18Procera® Abutment Wax-up Kit NobelActive™ . . . . . . . . . . . . . . . . . . 34991. . . . . . . . . . . . . . . . 19Procera® Abutment 3D CADD Kit NobelActive™. . . . . . . . . . . . . . . . . 34992. . . . . . . . . . . . . . . . 19

Try-in AbutmentsNobelReplace™ Try-in Abutment Kit. . . . . . . . . . . . . . . . . . . . . . 32414 . . . . . . . . . . . . . . 55Brånemark System® Try-in Abutment Kit . . . . . . . . . . . . . . . . . . 32415 . . . . . . . . . . . . . . 55Try-in Abutment Kit Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32429 . . . . . . . . . . . . . . 55

LLab Screw

Implant LevelLab Screw Implant Level Brånemark System® NP . . . . . . . . . . . . 31168 . . . . . . . 23,40,44,46Lab Screw Implant Level Brånemark System® RP 5/pkg . . . . . . . 29290 . . . . . . . 23,40,44,46Lab Screw Implant Level Brånemark System® WP . . . . . . . . . . . . 31169 . . . . . . . 23,40,44,46Lab Screw Implant Level NobRpl NP . . . . . . . . . . . . . . . . . . . . . 31170 . . . . . . . 37,40,44,46Lab Screw Implant Level NobRpl RP/WP 6.0 5/pkg . . . . . . . . . . . 29293 . . . . . . . 37,40,44,46

Multi-unit AbutmentLab Screw Multi-unit 5/pkg. . . . . . . . . . . . . . . . . . . . . . . . . . . . 29287 . . . . . . . . . . . . . . 28Lab Screw Multi-unit Brånemark System® WP . . . . . . . . . . . . . . . 31163 . . . . . . . . . . . . . . 28

Multi-unit Angled AbutmentLab Screw Multi-unit Angled Brånemark System® NP . . . . . . . . . 31164 . . . . . . . . . . . . . . 28Lab Screw Multi-unit Angled Brånemark System® RP . . . . . . . . . 31165 . . . . . . . . . . . . . . 28Lab Screw Multi-unit Angled NobRpl NP . . . . . . . . . . . . . . . . . . 31166 . . . . . . . . . . . . . . 28Lab Screw Multi-unit Angled NobRpl RP . . . . . . . . . . . . . . . . . . 31167 . . . . . . . . . . . . . . 28

MManual Torque Wrench Adapter Prosthetic . . . . . . . . . . . . . . . . . 29167 . . . . . . . . . . . . . . 61

PPlastic Coping

Easy Abutment™

Plastic Coping Easy Abutment™ Engaging NP . . . . . . . . . . . . . . . 30000 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™ Engaging RP . . . . . . . . . . . . . . . 29477 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™ Engaging WP. . . . . . . . . . . . . . . 29478 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™

Engaging ∅ 6 mm/Brånemark System® WP . . . . . . . . . . . . . . . . 29993 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™

Non-Engaging NP 2/pkg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30036 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™

Non-Engaging RP 2/pkg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29479 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™

Non-Engaging WP 2/pkg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29480 . . . . . . . . . . . . . . 38Plastic Coping Easy Abutment™

Non-Engaging ∅ 6 mm/Brånemark System® WP 2/pkg . . . . . . . 29994 . . . . . . . . . . . . . . 38Plastic Coping NobelPerfect® NP . . . . . . . . . . . . . . . . . . . . . . . . 30752 . . . . . . . . . . . . . . 30Plastic Coping NobelPerfect® RP. . . . . . . . . . . . . . . . . . . . . . . . . 30753 . . . . . . . . . . . . . . 30Plastic Coping NobelPerfect® WP . . . . . . . . . . . . . . . . . . . . . . . . 30754 . . . . . . . . . . . . . . 3010° Plastic Coping NobelPerfect® NP . . . . . . . . . . . . . . . . . . . . . 31237 . . . . . . . . . . . . . . 3010° Plastic Coping NobelPerfect® RP . . . . . . . . . . . . . . . . . . . . . 31238 . . . . . . . . . . . . . . 3010° Plastic Coping NobelPerfect® WP . . . . . . . . . . . . . . . . . . . . . 31239 . . . . . . . . . . . . . . 30

Plastic/Temporary CopingEsthetic Abutment

Plastic/Temp Coping Esthetic Abutment NP . . . . . . . . . . . . . . . . 32408 . . . . . . . . . . . . . . 26Plastic/Temp Coping Esthetic Abutment RP . . . . . . . . . . . . . . . . 32409 . . . . . . . . . . . . . . 26Plastic/Temp Coping Esthetic Abutment NobRpl WP . . . . . . . . . 32410 . . . . . . . . . . . . . . 26Plastic/Temp Coping Esthetic Abutment NobRpl 6.0/Bmk WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32172 . . . . . . . . . . . . . . 26Plastic/Temp Coping 15° Esthetic Abutment NP. . . . . . . . . . . . . 32787 . . . . . . . . . . . . . . 26Plastic/Temp Coping 15° Esthetic Abutment RP . . . . . . . . . . . . . 32788 . . . . . . . . . . . . . . 26Plastic/Temp Coping 15°Esthetic Abutment NobRpl WP . . . . . . . . . . . . . . . . . . . . . . . . . . 32789 . . . . . . . . . . . . . . 26Plastic/Temp Coping 15°Esthetic Abutment NobRpl 6.0/Bmk WP. . . . . . . . . . . . . . . . . . . 32790 . . . . . . . . . . . . . . 26

Snappy Abutment™

Plastic/Temp Coping Eng Snappy Abutment™ NP/RP. . . . . . . . . . 32356 . . . . . . . . . . . . . . 24Plastic/Temp Coping EngSnappy Abutment™ NobRpl WP . . . . . . . . . . . . . . . . . . . . . . . . . 32358 . . . . . . . . . . . . . . 24Plastic/Temp Coping Eng Snappy Abutment™ NobRpl 6.0/Bmk WP . . . . . . . . . . . . . . . . . . 32359 . . . . . . . . . . . . . . 24Plastic/Temp Coping Non-Eng Snappy Abutment™ NP/RP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32360 . . . . . . . . . . . . . . 24Plastic/Temp Coping Non-Eng Snappy Abutment™ NobRpl WP . . . . . . . . . . . . . . . . . . . . . . . . . 32362 . . . . . . . . . . . . . . 24Plastic/Temp Coping Non-Eng Snappy Abutment™ NobRpl 6.0/Bmk WP . . . . . . . . . . . . . . . . . 32363 . . . . . . . . . . . . . . 24

Position LocatorsPosition Locator Model Bmk Syst NP . . . . . . . . . . . . . . . . . . . . . 33413 . . . . . . . . . . . 31,34Position Locator Model Bmk Syst RP . . . . . . . . . . . . . . . . . . . . . 33414 . . . . . . . . . . . 31,34Position Locator Model Bmk Syst WP . . . . . . . . . . . . . . . . . . . . . 33415 . . . . . . . . . . . 31,34Position Locator Model NobRpl NP . . . . . . . . . . . . . . . . . . . . . . 33416 . . . . . . . . . . . 31,34Position Locator Model NobRpl RP. . . . . . . . . . . . . . . . . . . . . . . 33417 . . . . . . . . . . . 31,34Position Locator Model NobRpl WP . . . . . . . . . . . . . . . . . . . . . . 33418 . . . . . . . . . . . 31,34Position Locator Model NobRpl 6.0. . . . . . . . . . . . . . . . . . . . . . 33419 . . . . . . . . . . . 31,34Position Locator Model Multi-unit . . . . . . . . . . . . . . . . . . . . . . . 33422 . . . . . . . . . . . 31,34Position Locator Model Multi-unit WP . . . . . . . . . . . . . . . . . . . . 33423 . . . . . . . . . . . 31,34Position Locator Bridge Bmk Syst NP . . . . . . . . . . . . . . . . . . . . . 33424 . . . . . . . . . . . 31,34Position Locator Bridge Bmk Syst RP . . . . . . . . . . . . . . . . . . . . . 33425 . . . . . . . . . . . 31,34Position Locator Bridge Bmk Syst WP . . . . . . . . . . . . . . . . . . . . . 33426 . . . . . . . . . . . 31,34Position Locator Bridge NobRpl NP . . . . . . . . . . . . . . . . . . . . . . 33427 . . . . . . . . . . . 31,34Position Locator Bridge NobRpl RP. . . . . . . . . . . . . . . . . . . . . . . 33428 . . . . . . . . . . . 31,34Position Locator Bridge NobRpl WP . . . . . . . . . . . . . . . . . . . . . . 33429 . . . . . . . . . . . 31,34Position Locator Bridge NobRpl 6.0. . . . . . . . . . . . . . . . . . . . . . 33430 . . . . . . . . . . . 31,34Position Locator Bridge Multi-unit . . . . . . . . . . . . . . . . . . . . . . . 33433 . . . . . . . . . . . 31,34Position Locator Bridge Multi-unit WP . . . . . . . . . . . . . . . . . . . . 33434 . . . . . . . . . . . 31,34Pos Locator Model NobelActive™ Int NP . . . . . . . . . . . . . . . . . . . 34673 . . . . . . . . . . . 31,34Pos Locator Model NobelActive™ Int RP . . . . . . . . . . . . . . . . . . . 34674 . . . . . . . . . . . 31,34Pos Locator Bridge NobelActive™ Int NP . . . . . . . . . . . . . . . . . . . 34676 . . . . . . . . . . . 31,34Pos Locator Bridge NobelActive™ Int RP . . . . . . . . . . . . . . . . . . . 34678 . . . . . . . . . . . 31,34

Procera® Forte partsHolder Procera® Implant Bridge . . . . . . . . . . . . . . . . . . . A-5288-0043 . . . . . . . . . . . 31,342.5 mm Stylus Procera® Forte . . . . . . . . . . . . . . . . . . . . . A-5288-0044 . . . . . . . . . . . 31,34

Procera® ProductsProcera® Bridge Alumina . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Procera® Bridge Zirconia. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Procera® Crown Alumina . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Procera® Crown Zirconia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Procera® Laminate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Procera® Implant BridgeProcera® Implant Bridge Multi-unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Procera® Implant Bridge Multi-uni WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Procera® Implant Bridge Brånemark System® NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge NobelReplace™ NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge NobelReplace™ RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge NobelReplace™ WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge NobelReplace™ 6.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge Octagon 4.8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34Procera® Implant Bridge Octagon 6.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,34

Prosthetic ScrewProsthetic Screw Multi-unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29285 . . . . . . . . . . . 28,34Prosthetic Screw Multi-unit Brånemark System® WP . . . . . . . . . . 29286 . . . . . . . . . . . 28,34

Protection AnalogProtection Analog Brånemark System® NP 5/pkg . . . . . . . . . . . . 29116. . . . . . . . . . . . 40,44Protection Analog Brånemark System® RP 5/pkg . . . . . . . . . . . . 29117. . . . . . . . . . . . 40,44Protection Analog Brånemark System® WP 5/pkg . . . . . . . . . . . . 29118. . . . . . . . . . . . 40,44Protection Analog NobRpl NP 5/pkg . . . . . . . . . . . . . . . . . . . . . 29119 . . . . . . . . . 37,40,44Protection Analog NobRpl RP 5/pkg. . . . . . . . . . . . . . . . . . . . . . 29120. . . . . . . . . . . . 40,44Protection Analog NobRpl WP 5/pkg . . . . . . . . . . . . . . . . . . . . . 29121. . . . . . . . . . . . 40,44Protection Analog NobRpl 6.0 5/pkg . . . . . . . . . . . . . . . . . . . . 30043. . . . . . . . . . . . 40,44Protection Analog Multi-unit 5/pkg. . . . . . . . . . . . . . . . . . . . . . 29123 . . . . . . . . . . . . . . 29Protection Analog Multi-unit Brånemark System® WP 5/pkg . . . . . . . . . . . . . . . . . . . . . . . . . . 29124 . . . . . . . . . . . . . . 29Protect Analog NobelActive™ Int NP 5/pkg . . . . . . . . . . . . . . . . . . . . 34365. . . . . . . . . . . . . 40,44Protect Analog NobelActive™ Int RP 5/pkg . . . . . . . . . . . . . . . . . . . . 34366. . . . . . . . . . . . . 40,44

Page 66: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

66

Prod

uct Referen

ce Guid

e

index

RReplica Abutment Level

Ball AbutmentAbutment Replica Ball Abutment NP/RP . . . . . . . . . . . . . . . . . . . 29114 . . . . . . . . . . . 49,58

Easy Abutment™

Abutment Replica Easy Abutment™ NP . . . . . . . . . . . . . . . . . . . . 30042 . . . . . . . . . . . 38,58Abutment Replica Easy Abutment™ RP . . . . . . . . . . . . . . . . . . . . 29504 . . . . . . . . . . . 38,58Abutment Replica Easy Abutment™ WP. . . . . . . . . . . . . . . . . . . . 29505 . . . . . . . . . . . 38,58

Abutment ReplicaEasy Abutment™ 6 mm/Brånemark System® WP . . . . . . . . . . . . . 29996 . . . . . . . . . . . 38,58

Multi-unit AbutmentAbutment Replica Multi-unit 5/pkg . . . . . . . . . . . . . . . . . . . . . . 29110 . . . . . . . . . . . 28,57Abutment Replica Multi-unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 31161 . . . . . . . . . . . 28,57Abutment Replica Multi-unit Brånemark System® WP . . . . . . . . . 31162 . . . . . . . . . . . 28,57

Snappy Abutment™

Abutment Replica Snappy Abutment™ NP . . . . . . . . . . . . . . . . . 32368 . . . . . . . . . . . 24,58Abutment Replica Snappy Abutment™ RP. . . . . . . . . . . . . . . . . . 32369 . . . . . . . . . . . 24,58Abutment Replica Snappy Abutment™ NobRpl WP . . . . . . . . . . . 32370 . . . . . . . . . . . 24,58Abutment Replica Snappy Abutment™ NobRpl 6.0/Bmk Syst WP . . . . . . . . . . . . . . 32371 . . . . . . . . . . . 24,58

Implant LevelImplant Replica NobRpl NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29498 . . . . . . . . . . . 57,59Implant Replica NobRpl NP 20/pkg . . . . . . . . . . . . . . . . . . . . . . 29499 . . . . . . . . . . . 57,59Implant Replica NobRpl RP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29500 . . . . . . . . . . . 57,59Implant Replica NobRpl RP 20/pkg . . . . . . . . . . . . . . . . . . . . . . 29501 . . . . . . . . . . . 57,59Implant Replica NobRpl WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29502 . . . . . . . . . . . 57,59Implant Replica NobRpl WP 20/pkg . . . . . . . . . . . . . . . . . . . . . . 29503 . . . . . . . . . . . 57,59Implant Replica NobRpl 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . 29995 . . . . . . . . . . . 57,59Implant Replica Brånemark System® NP . . . . . . . . . . . . . . . . . . . 31158 . . . . . . . . . . . 57,59Implant Replica Brånemark System® RP 5/pkg . . . . . . . . . . . . . . 29108 . . . . . . . . . . . 57,59Implant Replica Brånemark System® RP . . . . . . . . . . . . . . . . . . . 31159 . . . . . . . . . . . 57,59Implant Replica Brånemark System® WP . . . . . . . . . . . . . . . . . . . 31160 . . . . . . . . . . . 57,59Implant Replica PS RP/NP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34556 . . . . . . . . . . . 22,57Implant Replica PS WP/RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34557 . . . . . . . . . . . 22,57Implant Replica NobelPerfect® NP . . . . . . . . . . . . . . . . . . . . . . . 29606 . . . . . . . . . . . 30,57Implant Replica NobelPerfect® RP. . . . . . . . . . . . . . . . . . . . . . . . 30997 . . . . . . . . . . . 30,57Implant Replica NobelPerfect® WP . . . . . . . . . . . . . . . . . . . . . . . 29608 . . . . . . . . . . . 30,57Implant replica NobelActive™ Internal NP . . . . . . . . . . . . . . . . . . 34243 . . . . . . . . . . . 57,59Implant replica NobelActive™ Internal RP . . . . . . . . . . . . . . . . . . 34244 . . . . . . . . . . . 57,59

SScrewdrivers

ManualScrewdriver Manual Ball Abutment 22 mm. . . . . . . . . . . . . . . . 29026 . . . . . . . . . . . . . . 61Screwdriver Manual Unigrip™ 20 mm . . . . . . . . . . . . . . . . . . . . 29148 . . . . . . . . . . . . . . 61Screwdriver Manual Unigrip™ 28 mm . . . . . . . . . . . . . . . . . . . . 29149 . . . . . . . . . . . . . . 61Screwdriver Manual Unigrip™ 36 mm . . . . . . . . . . . . . . . . . . . . 29150 . . . . . . . . . . . . . . 61Screwdriver Manual Multi-unit 25 mm . . . . . . . . . . . . . . . . . . . 29156 . . . . . . . . . . . . . . 61Screwdriver Manual Multi-unit Brånemark System® WP 25 mm . . . . . . . . . . . . . . . . . . . . . . . . . 29157 . . . . . . . . . . . . . . 61

MachineScrewdriver Machine Ball Abutment 24 mm . . . . . . . . . . . . . . . 29027 . . . . . . . . . . . . . . 61Screwdriver Machine Unigrip™ 20 mm . . . . . . . . . . . . . . . . . . . 29151 . . . . . . . . . . . . . . 61Screwdriver Machine Unigrip™ 25 mm . . . . . . . . . . . . . . . . . . . 29152 . . . . . . . . . . . . . . 61Screwdriver Machine Unigrip™ 30 mm . . . . . . . . . . . . . . . . . . . 29153 . . . . . . . . . . . . . . 61Screwdriver Machine Unigrip™ 35 mm . . . . . . . . . . . . . . . . . . . 29154 . . . . . . . . . . . . . . 61Screwdriver Machine Multi-unit 21 mm . . . . . . . . . . . . . . . . . . 29158 . . . . . . . . . . . . . . 61Screwdriver Machine Multi-unit Brånemark System® WP 20 mm . . . . . . . . . . . . . . . . . . . . . . . . . 29159 . . . . . . . . . . . . . . 61

Screwdriver/Activator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29163 . . . . . . . . . . . . . . 61

TTemporary Component

TitaniumTemporary Abutment Engaging Brånemark System® NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29028 . . . . . . . . . . . . . . . 5Temporary Abutment Engaging Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29030 . . . . . . . . . . . . . . . 5Temporary Abutment Engaging Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29032 . . . . . . . . . . . . . . . 5Temporary Abutment Non-Engaging Brånemark System® NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29029 . . . . . . . . . . . . . . . 5Temporary Abutment Non-EngagingBrånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29031 . . . . . . . . . . . . . . . 5Temporary Abutment Non-Engaging Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29033 . . . . . . . . . . . . . . . 5Temporary Abutment Engaging NobRpl NP . . . . . . . . . . . . . . . . 29034 . . . . . . . . . . . . . . . 5Temporary Abutment Engaging NobRpl RP . . . . . . . . . . . . . . . . 29036 . . . . . . . . . . . . . . . 5Temporary Abutment Engaging NobRpl WP. . . . . . . . . . . . . . . . 29038 . . . . . . . . . . . . . . . 5Temporary Abutment Engaging NobRpl 6.0 . . . . . . . . . . . . . . . 31456 . . . . . . . . . . . . . . . 5Temporary Abutment Non-Engaging NobRpl NP . . . . . . . . . . . . 29035 . . . . . . . . . . . . . . . 5Temporary Abutment Non-Engaging NobRpl RP . . . . . . . . . . . . 29037 . . . . . . . . . . . . . . . 5Temporary Abutment Non-Engaging NobRpl WP. . . . . . . . . . . . 29039 . . . . . . . . . . . . . . . 5Temporary Abutment Non-Engaging NobRpl 6.0 . . . . . . . . . . . 31457 . . . . . . . . . . . . . . . 5

Temporary Coping Multi-unit . . . . . . . . . . . . . . . . . . . . . . . . . . 29046 . . . . . . . . . . . . . . . 5Temporary Coping Multi-unit Bmk Syst WP . . . . . . . . . . . . . . . . 29047 . . . . . . . . . . . . . . . 5

PlasticTemporary Coping Easy Abutment™ Engaging NP/RP . . . . . . . . . 28903 . . . . . . . . . . . . . . . 5Temporary Coping Easy Abutment™ Engaging WP . . . . . . . . . . . 28904 . . . . . . . . . . . . . . . 5Temporary Coping Easy Abutment™ Engaging ∅ 6 mm/Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . 28905 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging Brånemark System® NP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30256 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30257 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30258 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging Brånemark System® NP . . . . . . . . . . . . . . . . . . . . . . . . . . . DCA 1048-0 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging Brånemark System® RP . . . . . . . . . . . . . . . . . . . . . . . . . . . DCA 1050-0 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging Brånemark System® WP . . . . . . . . . . . . . . . . . . . . . . . . . . . DCA 1052-0 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging NobRpl NP . . . . . . . . . . 30259 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging NobRpl RP . . . . . . . . . . . 30260 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging NobRpl WP . . . . . . . . . . 30261 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Engaging NobRpl 6.0. . . . . . . . . . 30262 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging NobRpl NP . . . . . . 31350 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging NobRpl RP . . . . . . . 31351 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging NobRpl WP . . . . . . 31352 . . . . . . . . . . . . . . . 5Temporary Abutment Plastic Non-Engaging NobRpl 6.0 . . . . . . 31353 . . . . . . . . . . . . . . . 5Temporary Coping Plastic Multi-unit . . . . . . . . . . . . . . . . . DCA 468-0 . . . . . . . . . . . . . . . 5Temporary Coping Plastic Multi-unit Bmk Syst WP . . . . . . . DCA 705-0 . . . . . . . . . . . . . . . 5

Try-In AbutmentNobelReplace™ Try-in Abutment Kit. . . . . . . . . . . . . . . . . . . . . . 32414 . . . . . . . . . . . . . . 55Brånemark System® Try-in Abutment Kit . . . . . . . . . . . . . . . . . . 32415 . . . . . . . . . . . . . . 55Try-in Abutments NobRpl NP . . . . . . . . . . . . . . . . . . . . . . . . . . . 32416 . . . . . . . . . . . . . . 56Try-in Abutments NobRpl RP . . . . . . . . . . . . . . . . . . . . . . . . . . . 32417 . . . . . . . . . . . . . . 55Try-in Abutments NobRpl WP. . . . . . . . . . . . . . . . . . . . . . . . . . . 32418 . . . . . . . . . . . . . . 55Try-in Abutments NobRpl 6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . 32419 . . . . . . . . . . . . . . 55Try-in Abutments Bmk Syst NP . . . . . . . . . . . . . . . . . . . . . . . . . . 32420 . . . . . . . . . . . . . . 55Try-in Abutments Bmk Syst RP . . . . . . . . . . . . . . . . . . . . . . . . . . 32421 . . . . . . . . . . . . . . 55Try-in Abutments Bmk Syst WP. . . . . . . . . . . . . . . . . . . . . . . . . . 32422 . . . . . . . . . . . . . . 55Try-in Abutment Kit Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32429 . . . . . . . . . . . . . . 55

WWax-up Sleeve

Wax-up Sleeve for Astra Tech® 3.5 ST . . . . . . . . . . . . . . . . . . . . 33553 . . . . . . . . . . . . . . 34Wax-up Sleeve for Astra Tech® 4.0 ST . . . . . . . . . . . . . . . . . . . . 33554 . . . . . . . . . . . . . . 34Wax-up Sleeve for Astra Tech® 4.5/5.0 ST . . . . . . . . . . . . . . . . . 33555 . . . . . . . . . . . . . . 34Wax-up Sleeve for Camlog® 3.3. . . . . . . . . . . . . . . . . . . . . . . . . 33567 . . . . . . . . . . . . . . 34Wax-up Sleeve for Camlog® 3.8. . . . . . . . . . . . . . . . . . . . . . . . . 33568 . . . . . . . . . . . . . . 34Wax-up Sleeve for Camlog® 4.3. . . . . . . . . . . . . . . . . . . . . . . . . 33569 . . . . . . . . . . . . . . 34Wax-up Sleeve for Camlog® 5.0/6.0 . . . . . . . . . . . . . . . . . . . . . 33570 . . . . . . . . . . . . . . 34Procera® Wax-up Sleeve Non-Engaging Octagon 4.8 . . . . . . . . 32005 . . . . . . . . . . . . . . 34Procera® Wax-up Sleeve Non-Engaging Octagon 6.5 . . . . . . . . 32006 . . . . . . . . . . . . . . 34Procera® Wax-up Sleeve Engaging Octagon 4.8 . . . . . . . . . . . . 31983 . . . . . . . . . . . . . . 34Procera® Wax-up Sleeve PS RP/NP . . . . . . . . . . . . . . . . . . . . . . . . 34555 . . . . . . . . . . . . . . 22Procera® W-u Sl Eng NobelActive™ Int NP . . . . . . . . . . . . . . . . . . 34208 . . . . . . . . . . . . . . 34Procera® W-u Sl Eng NobelActive™ Int RP . . . . . . . . . . . . . . . . . . 34209 . . . . . . . . . . . . . . 34Procera® W-u Sl Non-E NobelActive™ Int NP . . . . . . . . . . . . . . . . 34671 . . . . . . . . . . . . . . 34Procera® W-u Sl Non-E NobelActive™ Int RP . . . . . . . . . . . . . . . . 34672 . . . . . . . . . . . . . . 34

Page 67: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities
Page 68: Dental Laboratorydental.edwards.ro/images/brosuri/nobel_biocare/19955_LaboratoryM… · Thereafter, the NobelRondo™ procedure is an ideal alternative thatoffers unlimited possibilities

XX

XX

X G

B X

XX

X P

rinte

d in

Sw

eden

. © N

obel

Bio

care

Ser

vice

s A

G, 2

008.

Nob

el B

ioca

re, t

he N

obel

Bio

care

logo

typ

e an

d al

l oth

er t

rade

mar

ks u

sed

in t

his

docu

men

t ar

e, if

not

hing

els

e is

sta

ted

or is

evi

dent

from

the

con

text

in a

cer

tain

cas

e, t

rade

mar

ks o

f the

Nob

el B

ioca

re g

roup

.

AUSTRIANobel Biocare ÖsterreichPhone: +43 1 892 89 90

BELGIUMNobel Biocare BeneluxPhone: +32 2 467 41 70

DENMARKNobel Biocare DanmarkPhone: +45 39 40 48 46

FINLANDNobel Biocare SuomiPhone: +358 9 343 69 70

FRANCENobel Biocare FrancePhone: +33 1 53 33 89 10

GERMANYNobel Biocare DeutschlandPhone: +49 221 500 850

GREECENobel Biocare GreecePhone: +30 21 0804 94 93

HUNGARYNobel Biocare HungaryPhone: +36 1 279 3379

IRELANDNobel Biocare UKPhone: +353 1201 6412

ITALYNobel Biocare ItalianaPhone: +39 039 683 61

LITHUANIANobel BiocarePhone: +370 5 268 3448

NETHERLANDSNobel Biocare BeneluxPhone: +31 30 635 49 49

NORTH AMERICA

CANADANobel Biocare CanadaPhone: +1 905 762 3500Toll free: +1 800 263 4017

USANobel Biocare USAPhone: +1 714 282 4800Toll free: +1 800 993 8100Cust. support: +1 800 322 5001

CENTRAL/SOUTH AMERICA

ARGENTINANobel Biocare ArgentinaPhone: +54 11 4825 9696

BRAZILNobel Biocare BrasilPhone: +55 11 5102 7000

CHILENobel Biocare ChilePhone: +56 2 201 9282

ASIA PACIFIC

AUSTRALIANobel Biocare AustraliaPhone: +61 2 8064 5100

CHINANobel Biocare ShanghaiPhone: +86 21 5206 6655

HONG KONGNobel Biocare AsiaPhone: +852 2 845 12 66

INDIANobel Biocare IndiaPhone: +91 22 5551 9999

JAPANNobel Biocare JapanPhone: +81 3 6717 6191

NEW ZEALANDNobel Biocare New ZealandPhone: +61 2 8064 5100

SINGAPORENobel Biocare SingaporePhone: +65 6737 7967

TAIWANNobel Biocare TaiwanPhone: +886 987 874 580

COLOMBIANobel Biocare ColombiaPhone: +11 571 640 0608

MEXICONobel Biocare MexicoPhone: +52 55 524 974 60

AFRICA

SOUTH AFRICANobel Biocare South AfricaPhone: +27 11 802 0112

www.nobelbiocare.com

NORWAYNobel Biocare NorgePhone: +47 23 24 98 30

POLANDNobel Biocare PolskaPhone: +48 22 874 59 44

PORTUGALNobel Biocare PortugalPhone: +351 22 374 73 50

RUSSIANobel Biocare RussiaPhone: +7 495 974 77 55Phone: +8 800 200 9339

SPAINNobel Biocare IbéricaPhone: +34 93 508 88 00

SWEDENNobel BiocarePhone: +46 31 335 49 00

SWITZERLANDNobel BiocarePhone: +41 43 211 53 20

UNITED KINGDOMNobel Biocare UKPhone: +44 1895 430 650

EUROPE, MIDDLE EAST & RUSSIA

Nobel Biocare global presence

Nobel Biocare cares about

the environment and all

production units are certifi ed

according to Environmental

Management System ISO 14001

v 8:2a

1995

5 G

B Lo

t “0

811”

Prin

ted

in S

wed

en ©

Nob

el B

ioca

re S

ervi

ces

AG

, 20

08.

Nob

el B

ioca

re,

the

Nob

el B

ioca

re lo

goty

pe

and

all o

ther

tra

dem

arks

use

d in

thi

s do

cum

ent

are,

if n

othi

ng e

lse

is s

tate

d or

is e

vide

nt f

rom

the

con

text

in a

cer

tain

cas

e, t

rade

mar

ks o

f th

e N

obel

Bio

care

gro

up.