12
CABLE High temperature resistant up to 120ºC, the cable is built with double insulation. Its halogen-free outer sheath is flame resistant and protect against aging and UV. Standards: TUV certification 2pfG 1169/08.07 Comply with UTE C15-712 and UTE C32-502 guide Life Span: 25 years Construction: Inner conductor: Tinned copper class 5 according to IEC60228 Insulator: XL-HFFR White or Black Outer sheath: XL-HFFR, thermoplastic, halogen free. Electrical characteristics Operating voltage: 09/1.8Kv DC – 06/1Kv AC Operating temperature: 40ºC to 90ºC Max Temperature: 120ºC Fire, UV and ozone resistant Minimum radius: 5x ext. Diameter CONNECTORS AND ACCESSORIES Cable connectors allow to realize a reliable interface between the panels and the inverter. IP67, connectors meet all the requirement related to safety (class II) and the market standards. Cable section: 4, 6, 10 mm 2 Advantages: Secured connectors for user’s safety Excellent electrical conductivity Electrical characteristics: Tension: 1Kv DC Resistance <5Ω Sealing: IP 67 according to IEC60529 Operating temperature: -40ºC to +85ºC CABLE, CONNECTOR, & ACCESSORIES SOL2.5BK SOL4BK SOL6BK SOL10BK SOL16BK SOL25BK Black* 1x2.5mm 2 Black* 1x4mm 2 Black* 1x6mm 2 Black* 1x10mm 2 Black* 1x16mm 2 Black* 1x25mm 2 DIAMETER *: Red and Blue available upon request SOLAR 25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com 5.2 mm 6 mm 6.6 mm 8.2 mm 9.7 mm 10.9 mm DESCRIPTION REFERENCES

DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

  • Upload
    trannhi

  • View
    215

  • Download
    2

Embed Size (px)

Citation preview

Page 1: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

CABLE

High temperature resistant up to 120ºC, the cable is built with double insulation. Its halogen-free outer sheath is flame resistant and protect against aging and UV.

Standards:• TUV certification 2pfG 1169/08.07• Comply with UTE C15-712 and UTE C32-502 guide• Life Span: 25 years

Construction:• Inner conductor: Tinned copper class 5 according to IEC60228• Insulator: XL-HFFR White or Black• Outer sheath: XL-HFFR, thermoplastic, halogen free.

Electrical characteristics• Operating voltage: 09/1.8Kv DC – 06/1Kv AC• Operating temperature: 40ºC to 90ºC• Max Temperature: 120ºC• Fire, UV and ozone resistant• Minimum radius: 5x ext. Diameter

CONNECTORS AND ACCESSORIES

Cable connectors allow to realize a reliable interface between the panels and the inverter. IP67, connectors meet all the requirement related to safety (class II) and the market standards.

Cable section: 4, 6, 10 mm2

Advantages:• Secured connectors for user’s safety• Excellent electrical conductivity

Electrical characteristics:• Tension: 1Kv DC• Resistance <5Ω• Sealing: IP 67 according to IEC60529• Operating temperature: -40ºC to +85ºC

CABLE, CONNECTOR, & ACCESSORIES

SOL2.5BK

SOL4BK

SOL6BK

SOL10BK

SOL16BK

SOL25BK

Black* 1x2.5mm2

Black* 1x4mm2

Black* 1x6mm2

Black* 1x10mm2

Black* 1x16mm2

Black* 1x25mm2

DIAMETER

*: Red and Blue available upon request

SOLAR

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

5.2 mm

6 mm

6.6 mm

8.2 mm

9.7 mm

10.9 mm

DESCRIPTION REFERENCES

Page 2: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

G 100 G 125 G 165Inner conductor 1.00mm CU 1.25 mm CU 1.65 mm CUInsulation Physical Foam PE Physical Foam PE Physical Foam PEDiameter over insulation 4.6mm 5.5mm 7.25mmOuter conductor CU foil CU foil CU foilBraid CU 45% CU 45% CU 50%Sheath material PVC/LSZH PVC/LSZH PVC/LSZHOver sheath Ø 6.7 mm 7.9mm 10.1 mmSheath color** Black Black Black

••

20ft container

100m, 305m, 500m, 1000m Drum

CAI TYPE

TECHNICAL DATA

PACKING AND MOQ

In order to meet our customer needs; we developed a range of high quality coaxial cable, required for TV and satellite installation. Those coaxial cables have been manufactured according to CAI Benchmark Scheme* and are RoHS compliant.Our CAI range’s copper foil and braiding construction gives our cables a higher degree of screen-ing. The physical Foam PE insulation protects the conductor and creates a watertight dielectric. It gives our cable a better durability, a better resistance to bending and other mechanical stress.

JacketBraidingCu-FoilConductorInsulation

G100, G125 and G165 are used by professional installation companies for cabling multi-point system.

3 TYPES OF GAUGES:

INTRODUCTION

s* * Our cable are also available in Brown and White.* Our coax range is not meant to be registered in our own trademark.

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

Coaxial Cable

Page 3: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

UHF Aerials : Yagi & Lambda series

17 VATC19 VATC21 VATC

VHF AerialsLOG Antennas

Dish: Composite, Aluminum & SteelLNB: Single / Duo

DISEqC Switches Indoor & Outdoor Waterproof box available

Amplifiers, Mixers, DISEqC Switches, Power SupplyIndoor Amplifier TV / SAT

SAT / TV / FM

SPLITTERS: Satellite & Terrestrial TAPS: Satellite & Terrestrial

TV & SAT ACCESSORIES

WALL SOCKETS

TERRESTRIAL ANTENNAS SATELLITE DISHES & LNB

TOOLS & CONNECTORS

F Connectors Compression, Screw, Crimping types

COAXIAL CABLES(CATV / SMATV)

ANTENNA & ACCESSORIES

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

Page 4: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

SPEAKER CABLES

MICROPHONE CABLES

CONNECTORS

AUDIO & VIDEO CORDS

Black & Red/White/Black/Marron/TransparentFrom 0.5mm2 to 4.0 mm2

Different Composition are availableStandard PVC & Extra flexible

BNCConnectors RCA

Audio Jack- RCAS-VHS BNCRCA AVXLR Male / FemaleCS-VGAHDMI

Coaxial cable: RG 59 RG 6 HD 59 HD 6 Green Video Coax Composite cable (Video coax + Power cords)

AUDIO / VIDEOCOAXIAL CABLES TYPES

Page 5: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an
Page 6: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

Those cables have different construction (from 1 to12 pairs) and can be used for different application, such as General electrical equipment, internal wiring audio, control and instrumentation.

> 305m, 500m and 1000m Drum> 10km/ item> 1x20ft container

UL style

Hook-Up wire:

Control cables

Packing and MOQ

All our UL style cables are built in accordance with the UL & CSA specifications and have been tested according to established procedures.Our range is divided in two main categories; all the cables are available with different copper conductor sizes (AWG12 to 30).

> UL1581, horizontal tray> UL1685, vertical tray

This category has very simple construction and a lot of different application, Such as household appliance, illumination and lighting; Motor, cars and ships electrical installation; or internal appli-ances wiring or electrical equipment.

> PVC basic (up to 105°C) > LSZH (up to 90°C) > PVC flame retardant (up to 105°C) > XLPE (up to 150°C)> PE (up to 80°C) > FEP (up to 200°C)> PP (up to 80°C)

Flame test:

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

UL type Insulation1007(TR-64) 1015(TEW) 1028 1061 1283 1330 1332 3173 3266 3271 3321 10138 PE10152 PP

Insulation/Jacket material:

UL style Insulation Jacket2092 PE 2095 PP/PVC 2464 PVC 2493 Foam PE 2598 PVC 2919 PP/PE/Foam PE

InsulationConductor

InsulationConductor

InsulationConductor

JacketAl PetInsulationConductorDrain wire

JacketInsulationConductor

JacketAl PetInsulationConductorDrain wire

XLPE

PVC

PVC

Page 7: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

W Sticker

High end range of splitterCable pass under splitter from 7 to 9 mm height Terrestrial and satellite splitter with power pass from input to outputScrew type female F-connector

TSpXX range

Item

TSp02: 1 input, 2 outputs

TSp03: 1 input, 3 outputs

TSp04: 1 input, 3 outputs

TSp06: 1 input, 6 outputs

52x60x26 / 9

52x60x26 / 9

75x60x26 / 9

120x60x26 / 7

Dimension LxWxH/Cable pass (mm)

Cost efficient housingCable pass under splitter from 7 to 9 mm height Terrestrial and satellite splitter with power pass from input to outputScrew type female F-connector

SpX range

Item Dimension LxWxH/Cable pass (mm)Sp2 - 1 input, 2 outputs

Sp3 - 1 input, 3 outputs

Sp4 - 1 input, 4 outputs

Sp6 - 1 input, 6 outputs

40x54x25 / 9

40x54x25 / 9

40x54x25 / 9

105x58x25 / 7

Electrical DataInsertion loss (dB):

1 input, 2 outputs:

1 input, 3 outputs:

5 to 1000MHZ: 4.01000 to 1700MHz: 4.51700 to 2400MHz: 5.5

5 to 1000MHZ: 6.01000 to 1700MHz: 7.01700 to 2400MHz: 8.5

Splitters :Divide signal from 1 input to XXoutputs*

Mechanical Data

*From 1 output to 6 outputs

Taps,Splitters and Couplers Range

L

H

Cable pass

5 to 1000MHZ: 8.01000 to 1700MHz: 9.01700 to 2400MHz: 10.5

5 to 1000MHZ: 11.51000 to 1700MHz: 12.51700 to 2400MHz: 15.5

1 input, 4 outputs:

1 input, 6 outputs:

Screening efficency:5 to 470 MHz >75dB

470 to 1000 MHz >65dB

1000 to 2300 MHz >60dB

Page 8: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

W Sticker

TAPXX-XX rangeInsertion loss from 1 to 4 dB depending on frequencyTypical insulation 25dB between outputsPower pass from input to outputScrew type female F-connectorWith or without Cable pass under taps ( 9mm height)

2 outputs

4 outputs

6 outputs

8 outputs

TAP 02-10

TAP 02-12

TAP 02-16

TAP 02-20

TAP 04-10

TAP 04-12

TAP 04-16

TAP 04-20

TAP 06-16

TAP 06-20

TAP 08-16

TAP 08-20

From 5 to 950HMz: 16 dB

From 950 to 2400MHz : 17dB

From 5 to 950HMz: 20 dB

From 950 to 2400MHz : 21dB

From 5 to 950HMz: 10 dB

From 950 to 2400MHz : 11dB

From 5 to 950HMz: 12 dB

From 950 to 2400MHz : 13dB

From 5 to 950HMz: 16 dB

From 950 to 2400MHz : 17dB

From 5 to 950HMz: 20 dB

From 950 to 2400MHz : 21dB

From 5 to 950HMz: 10 dB

From 950 to 2400MHz : 11dB

From 5 to 950HMz: 12 dB

From 950 to 2400MHz : 13dB

From 5 to 950HMz: 16 dB

From 950 to 2400MHz : 17dB

From 5 to 950HMz: 20 dB

From 950 to 2400MHz : 21dB

From 5 to 950HMz: 16 dB

From 950 to 2400MHz : 17dB

From 5 to 950HMz: 20 dB

From 950 to 2400MHz : 21dB

Item Taps loss

2 outputs: 60x54x26

4 outputs: 60x76x26

6 outputs: 65x122x26

8 outputs: 65x122x26

Dimension LxWxH (mm)

Taps,Splitters and Couplers Range

Taps : Divert a predetermined amount of its input signal energy to XXXoutputs*,with the remaining balance of the output energy going through outlet.

*From 1 output to 8 outputs

Electrical Data

L

H

Cable pass

Mechanical Data

Page 9: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

Couplers :

L

H

W Sticker

Coupling/decoupling satellite and terrestrial signal

58x22x17

Dimension LxWxH (mm)

Taps,Splitters and Couplers Range

Electrical Data

CP-XX-ST range

High screening efficency

Screw type female F-connector

Return loss > 10dB

Terrestrial: 47 to 862MHz=1.5dBSatellite: 950 to 2400=1.5dB

Item Insertion loss

CP-02-ST

Mechanical Data

Page 10: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

RG6 Satellite Cable

RG6 Class A

CATV networks are used to transfer high frequency signals from source to household installation, they also use return path band with low frequency signal under 30MHz (e.g.: Internet connection or Pay TV).

In order to indicate the outer conductor ability to prevent the inner signal and outside distur-bance to interfere with each other, it requires 2 key features: Screening efficiency and Transfer Impedance.

According to EN50117, coaxial cables are categorized in different classes, based on shielding efficiency.

This cable has a Copper Clad Steel inner conductor and is tri-shielded. The shield is build with an Aluminum foil bonded to the foam PE insulation, an Aluminum Braiding and a second Aluminum Foil (thicker than the first).

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

Class A and Class A+

Inner conductor 1.02 mm Copper Clad Steel

ShieldFoil1BraidingFoil 2

-55% coverage

-

Al-Pet BondedAluminumAl-Pet-Al

Outer jacket 6.80 mm

Screening Efficiency 30~1000MHz 105 dB

Transfer Impedance5~30MHz <5mΩ/m -

-

PVC/LSZH

Screening efficiency test

Screening Efficiency Transfer Impedance

ACLASSE

EN 50117ACLASSE

EN 50117

+

Page 11: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

RG6 Class A+

This cable has a Bare Copper inner conductor and is tri-shielded. The shield is build with an Aluminum foil bonded to the foam PE insulation, a Copper Braiding and a second Aluminum Foil (thicker than the first).

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com

Inner conductor 1.02 mm-

50% coverage-

7.06 mm

ShieldFoil1BraidingFoil 2

Bare CopperAl-Pet Bonded

CopperAl-Pet-Al

PVC/LSZHOuter jacket

Screening Efficiency 30~1000MHz 120dB

Transfer Impedance5~30MHz <2.5 mΩ/m -

-

Screening efficiency test

Screening Efficiency Transfer Impedance

RG6 Satellite Cable Class A and Class A+A

CLASSE

EN 50117ACLASSE

EN 50117

+

Page 12: DESCRIPTION REFERENCES DIAMETER - Symeasymea-group.com/Cables-2.pdf · UHF Aerials : Yagi & Lambda series 17 VATC 19 VATC ... 1700 to 2400MHz: 8.5 ... The shield is build with an

Our cable accessories range purpose is to effectively complete our customer’s cable range.

Each item of this range comes with different dimensions and are manufactured according to

European standards

Cable Accessories

F ConnectorScrew, Crimp,

compression type

ToolsCrimping and Compression

Cable puller

Cable

Cable TiesDifferent material,

dimension and color

25, Wuxing Lu, B2 Room 702 Zip 200031 Shanghai Email : [email protected] www.symea-group.com