DESIGN CRITERIA
Property:
Reinforced Concrete Design
Beams = 400 x 600 mm
Columns = 400 x 400 mm
Steel Design
Beams = W14 x 370
Columns = W33 x 515
Slab Thickness = 120 mm
Design Parameters:
f’c = 27 MPa
fy = 414 MPa
Load System:
I. SEISMIC LOAD
As of UBC 1997
Zone 2 = 0.20, Manila
Importance factor, I = 1.0
Rw in X Direction (RWX) = 8.5
Rw in Z Direction (RWZ) = 8.5
Soil Profile Type, (Hard Rock)= 1
Near source factor (Na) = 1.00
Near source factor (Nv) = 1.00
Ct = 0.0853 for steel moment resisting frames
Ct = 0.0731 for rc moment resisting frames
II. WIND LOAD
As of ASCE – 7, 2002
Building Classification Category = Category I
Basic Wind Speed,V = 200 kmph
Exposure Category = Exposure B
Structure Type = Building Structures
Building Height = 15.5m
Building Length along the direction of Wind(L) = 30m
Building Length Normal to the direction of wind (B)= 24m
Building Natural Frequency = 2 Hz
Building Damping Ratio = 0.01
Enclosure Classification: Partially Enclosed
III. DEAD LOAD
1. Floor Slab (Self Weight)
2. 6” Hollow Concrete Masonry Units Plastered
on Both Side (Full Grout Spacing) = 3.11 kPa
3. 4” Hollow Concrete Masonry Units Plastered
on Both Side (Full Grout Spacing) = 2.98 kPa
4. Stairs = 4.00 kPa
5. Wood Block (76 mm) on 13mm Mortar Base = 0.77 kPa
6. Solid Flat Tile on 25mm Mortar Base = 1.10 kPa
7. Ceramic Tile (20 mm) on 13mm Mortar Bed = 0.77 kPa
8. Suspended Metal Lath and Gypsum Plaster = 0.48 kPa
9. Ordinary Plywood (1/8”)
with 2x2 Ceiling Joist = 0.24 kPa
10. Wood Furring Suspension System = 0.12
kPa
11. Electromechanical = 0.10 kPa
12. Interior Partitions = 1.00 kPa
13. Waterproofing, Bituminous Smooth Surface= 0.07 kPa
IV. LIVE LOAD:
1. Stairs = 4.80 kPa
2. Restroom = 1.90 kPa
3. Hallway = 2.90 kPa
4. Residential = 1.90 kPa
Member Load:
2nd Floor
WEXT = 3.11 x 3.25 = 10.11 kN/m
WINT = 2.98 X 3.25 = 9.69 kN/m
3RD Floor, 4th Floor, 5th Floor
WEXT = 3.11 x 3.00 = 9.33 kN/m
WINT = 2.98 X 3.00 = 8.94 kN/m
Stair
W = 4.00 x 5.00 = 20 kN/m
Floor Load:
DEAD LOAD
Bedroom Unit
W = (4) + (5) + (8) + (9) + (10) = 2.32 kPa
Hallway
W = (6) + (7) + (10) = 1.35 kPa
LIVE LOAD
Restroom = 1.90 kPa
Hallway = 2.90 kPa
Residential = 1.90 kPa