Development Management Department1 of 49
ENERGY EFFICIENCYNATIONAL BUILDING REGULATIONS
Development Management Department2 of 49
BACKGROUND
EE
- N
BR
Development Management Department3 of 49
National Energy Efficiency Strategyof the Republic of South Africa
March 2005( Reviewed 2008 / 2011 )
EE
- N
BR
Development Management Department4 of 49
OBJECTIVES
● Develop and implement energy efficiency practices in SA
● Contribute to affordable energy for all
● Minimise the negative effects of energy usage upon● human health and the environment
● Set a national target for energy efficiency improvement● [ 12% by 2015 ]
● Cover all energy-using sectors
EE
- N
BR
Development Management Department5 of 49
ACHIEVED THROUGH
● Economic and legislative means
● Efficiency labelling
● Performance standards
● Energy management
● Energy auditing
● Promote efficiency practices
National Building Regulationsand
Building Standards Act(Act No. 103 of 1977)
SANS 10400-XASANS 204
SANS 10252EE
- N
BR
Development Management Department6 of 49
ENERGY USAGE SECTORS
● Industry and Mining
● Commercial and Public Buildings
● Residential
● TransportEE
- N
BR
Development Management Department7 of 49
EE
- N
BR
Development Management Department8 of 49
National Building Regulationsand
Building Standards ActNo. 103 of 1977
EE
- N
BR
Development Management Department9 of 49
09 November 2011
EE
- N
BR
Development Management Department10 of 49
Part X: Environmental sustainability
XA: Energy usage in buildings
EE
- N
BR
Development Management Department11 of 49
XA: Energy usage in buildings
XA1 ● To contribute to the reduction of greenhouse gases
– buildings, and– extensions to buildings
of occupancy classifications...EE
- N
BR
Development Management Department12 of 49
● A1 - Entertainment and public assembly● A2 - Theatrical and indoor sport● A3 - Places of instruction● A4 - Worship● C1 - Exhibition hall● C2 - Museum● E1 - Place of detention● E2 - Hospital● E3 - Other institutional (residential)● E4 - Health care● F1 - Large shop● F2 - Small shop● F3 - Wholesaler's store● G1 - Offices● H1 - Hotel● H2 - Dormitory● H3 - Domestic residence● H4 - Dwelling house● H5 - Hospitality
excluding:garage and storage areas containedwithin such occupancies
Not covered by NBR Part XA5 - Outdoor sportB1 - High risk commercial serviceB2 - Moderate risk commercial serviceB3 - Low risk commercial serviceD1 - High risk industrialD2 - Moderate risk industrialD3 - Low risk industrialD4 - Plant room
EE
- N
BR
Development Management Department13 of 49
shall be designed and constructed so that they...
EE
- N
BR
Development Management Department14 of 49
(a)● use energy efficiently in relation to:
– vertical transport;– thermal comfort;– lighting; and– hot water; or...E
E -
NB
R
Development Management Department15 of 49
(b) ● have:
– building envelope; and– services
which facilitate efficient use of energy appropriate to their:
● function and use,● internal environment; and● geographical location.
EE
- N
BR
Development Management Department16 of 49
EE
- N
BR
Development Management Department17 of 49
EE
- N
BR
13 Climatic Zones
Development Management Department18 of 49
EE
- N
BR
8 Climatic Zones
Development Management Department19 of 49
Equipment and plant for conducting business – excluded.
EE
- N
BR
Development Management Department20 of 49
XA2 ● At least 50% annual average hot water heating shall be:
– by means other than electrical resistance heating● including but not limited to:
– solar heating;– heat pumps;– heat recovery systems / processes; and– renewable combustible fuel.
(volume fraction)calculated in accordance with SANS 10252-1
EE
- N
BR
Development Management Department21 of 49
XA3 ● XA1 shall be deemed satisfied when:
– building is:● designed; and● constructed
in accordance with -EE
- N
BR
Development Management Department22 of 49
(a) ● SANS 10400-XA requirements for:
– orientation;– shading;– services; and– building envelope; or...
EE
- N
BR
Development Management Department23 of 49
(b) ● rational design prepared by competent person:
– which demonstrates that energy usage of building is:● equivalent to; or● better than;
that which would be achieved by compliance with
SANS 10400 XA, or...
EE
- N
BR
Development Management Department24 of 49
(c) ● theoretical energy usage performance,
– less than; or– equal to;
a reference building in compliance with SANS 10400-XA :( using certified thermal calculation software )
certified thermal calculation softwaresoftware certified by Agrément SA,in terms of Agrément SA Energy Software Protocols
EE
- N
BR
- BSIMAC (Version 9) Building Energy Analysis Software- DesignBuilder (Version 3.1) Building Energy Analysis Software- IES Virtual Environment Software (Version VE 2013)- StarFront Software for designing compliant aluminium windows and doors
Development Management Department25 of 49
SANS 10400-XA
EE
- N
BR
Development Management Department26 of 49
(a) Functional regulations of part XA of NBR satisfied where:
● competent person certifies building as having:
– theoretical annual energy consumption; and– theoretical annual energy demand
less than or equal to collected data tabled
● A1, A2, A3, A4, F1, G1, or H1,
● (excluding garage and storage areas), or...
A1 - Entertainment and public assemblyA2 - Theatrical and indoor sportA3 - Places of instructionA4 – WorshipF1 - Large shopG1 – OfficesH1 - Hotel
EE
- N
BR
Development Management Department27 of 49
EE
- N
BR
Development Management Department28 of 49
(b) Functional regulations of part XA of NBR satisfied where:
● building:
– orientation;– shading;– external walls;– fenestration;– roof assembly construction;– in-slab heating installation;– services that use energy or control the use of energy:
● heating, air conditioning and mechanical ventilation;– hot water system
is in accordance with requirements of SANS XA & 204
EE
- N
BR
Development Management Department29 of 49
● A1 - Entertainment and public assembly● A2 - Theatrical and indoor sport● A3 - Places of instruction● A4 - Worship● C1 - Exhibition hall● C2 - Museum● E1 - Place of detention● E2 - Hospital● E3 - Other institutional (residential)● E4 - Health care● F1 - Large shop● F2 - Small shop● F3 - Wholesaler's store● G1 - Offices● H1 - Hotel● H2 - Dormitory● H3 - Domestic residence● H4 - Dwelling house● H5 - Hospitality
EE
- N
BR
Development Management Department30 of 49
(c) Functional regulations of part XA of NBR satisfied where:
● competent person certifies building as having:
– theoretical annual energy consumption; and– theoretical annual energy demand
less than or equal to reference building complying with (b)EE
- N
BR
Development Management Department31 of 49
RESPONSIBILITYfor
DESIGN ACHIEVING COMPLIANCE ?
EE
- N
BR
LOCAL AUTHORITY
WHY ??
Development Management Department32 of 49
AZ4 Complying with the requirements of the National Building Regulations
(1) National Building Regulations shall be complied with by:
(a) adhering to all prescriptive regulations; and
(b) satisfying all functional regulations by:
(i) adopting solutions that comply with SANS 10400; or
(ii) rational design / assessment having equivalent / superior performance to solution complying with
SANS 10400.
EE
- N
BR
Development Management Department33 of 49
PART A - ADMINISTRATION
A1 APPLICATION
(1) Designing, planning and the supervision of the erection of any
building or structure...
...is subject to the provisions of any law in terms of which the
person undertaking such work...
...is required to be registered in terms of the Architectural Profession Act, 2000, Engineering Profession Act, 2000,…, or any other relevant Act.
EE
- N
BR
Development Management Department34 of 49
A2 PLANS AND PARTICULARS TO BE FURNISHED
(1) Any person intending to erect any building shall submit to the
local authority the following plans and particulars, together with the application:...
(g) a declaration by a person registered in a professional
category of registration...
...in Form 1 contained in SANS 10400-A as to how the applicable functional regulations shall be satisfied;
EE
- N
BR
Development Management Department35 of 49
DECLARATION FORM
EE
- N
BR
Development Management Department36 of 49
Identify the applicability of theRegulation i.t.o the proposal.Do NOT leave blank or tick both.
FORM 1
EE
- N
BR
Development Management Department37 of 49
FORM 1
Competent person is as defined in the relatedSANS 10400 code and are function specific.
Name of person to be appointed to be identified,not name of business representing
EE
- N
BR
Development Management Department38 of 49
FORM 2
Owner and competent person both initial confirmingthe work the competent person is responsible for andfor which certification will be required on completionof the building.Such being necessary prior to applyingfor a Certificate of Occupation from the local authority.
The applicable duty is determined by thatidentified in Schedule B of Form 1.
EE
- N
BR
Development Management Department39 of 49
The acceptance of a competent person by a localauthority is application specific and forms part of theapproval of an application.
FORM 2
Aspects the local authority must considerwhen considering the acceptability of acompetent person i.t.o the work for whichappointed
Acceptability or Not of competent personto be endorsed by the local authority onconsideration of the application
EE
- N
BR
Development Management Department40 of 49
EE
- N
BR
Development Management Department41 of 49
Competent person to identify the aspect/sfor which the “Certificate of Completion” is
being issued
Certificate of Completion is issued i.t.o an “APPROVAL”granted by the local authority.Certificate of Completion cannot be issued i.t.o work forwhich no approval has been granted or which deviatesfrom an approval granted (unauthorised work ?)
EE
- N
BR
Development Management Department42 of 49
RESPONSIBILITYfor
DESIGN ACHIEVING COMPLIANCE ?
EE
- N
BR
APPOINTEDREGISTERED PROFESSIONAL
ORCOMPETENT PERSON
Development Management Department43 of 49
VARIANCE FROM APPROVAL
IMPLICATIONS
EE
- N
BR
Development Management Department44 of 49
BUILDING APPLICATION APPROVAL
● Based on:
– Application & supporting documentation;– Declaration by Appointed Registered Professional;– Building Plans – NBR complianceE
E -
NB
R
Development Management Department45 of 49
DEVIATION FROM APPROVAL
● Results in:
– Building Plan approval no longer being valid;– Declaration by Registered Professional being voided;– NBR compliance may no longer be possible.
Minor changes may have major impact onEnergy Efficiency compliance achieved byoriginal design solution
EE
- N
BR
Development Management Department46 of 49
Requirement for Water Layouts
SANS 10252-1
EE
- N
BR
Development Management Department47 of 49
Water Services ActNo. 108 of 1997
Regulations Relating to Compulsory National Standards and Measures to Conserve Water
R 509 of 8 June 2001EE
- N
BR
Development Management Department48 of 49
Consumer installations other than meters
14. Every consumer installation must comply with - SABS 0252: Water Supply and Drainage for Buildings and
- SABS 0254: The Installation of Fixed Electric Storage Water Heating Systems, or
any similar substituting re-enactment or amendment thereof if the consumer installation is of a type regulated by either standard.
EE
- N
BR
Read as:SANS 10252 – 1 & 2 and SANS 10254
Development Management Department49 of 49
SANS 10400-XA
4.1.1To comply with regulation XA2 :(a) volume of annual average hot water heating requirements shall be calculated i.t.o tables 2 and 5 of SANS 10252-1; and
(b) if solar water heating systems are used, these shall comply with SANS 1307, SANS 10106, SANS 10254 and SANS 10252-1.
EE
- N
BR
Development Management Department50 of 49
QUESTIONS ??
EE
- N
BR