35
Developmen t of the Envelope Criteria Merle McBride, Ph.D., P.E Senior Research Associate Owens Corning ASHRAE Representative At Large Orlando, FL

Development of the Envelope Criteria Merle McBride, Ph.D., P.E Senior Research Associate Owens Corning ASHRAE Representative At Large Orlando, FL February

Embed Size (px)

Citation preview

Development of the

Envelope Criteria

Merle McBride, Ph.D., P.ESenior Research Associate

Owens Corning

ASHRAERepresentative At Large

Orlando, FL

February 7, 2005

Agenda- Objective- Problem Statement- Background- Approach- Analysis- Results- Conclusions- Recommendations- Q & A

Objective

Develop prescriptive criteria that will result in a 30% energy savings relative to

ANSI/ASHRAE/IESNA Standard 90.1-1999.

Problem Statement

Include in Analysis:

- Envelope

- HVAC

- O.A. Damper Controls

- SWH

- Interior Lighting

Exclude from Analysis:

- Exterior Lighting

- Plug Loads (Office Equip. & Appliances)

Background 90.1 Development

• LCC Economics

• Classes of Construction

• Base Energy Usage– Climate Zones– Constructions– Size

Classes of Construction• Roofs

– Ins. Above Deck– Metal Building– Attic and Other

• Walls, Above Grade– Mass– Metal Building– Steel Framed– Wood Framed & Other

• Floors– Mass– Steel Joist– Wood Framed & Other

• Walls, Below Grade

• Slab –On-Grade– Unheated– Heated

• Opaque Doors– Swinging– Non-Swinging

• Fenestration (U, SHGC)– 10%, 20%, 30%, 40%, 50%

• Skylights (3% max.)– Curb, Glass– Curb, Plastic– No Curb

U.S. Weather Data and 90.1 26 Climate Zones

0

900

1800

2700

3600

4500

5400

6300

7200

8100

9000

9900

10800

11700

126000

90

0

18

00

27

00

36

00

45

00

54

00

63

00

72

00

81

00

90

00

99

00

10

80

0

11

70

0

12

60

0

13

50

0

14

40

0

15

30

0

16

20

0

17

10

0

18

00

0

18

90

0

19

80

0

20

70

0

21

60

0

22

50

0

23

40

0

HDD65

CD

D50

1

2

3

4

5

7

8

9

10

12

13

15

16

18

1921

22

23 24 25 26

11

14 17

20

6

8 Climate Zones, 15 Cities

0900

1800270036004500540063007200810090009900

10800

0

1800

3600

5400

7200

9000

1080

0

1260

0

1440

0

1620

0

HDD65

CD

D50

1

2

3A,B

3C 4 5 6 7 8

15 Cities

90.1-2004 and SP102 8 Climate Zones, Counties Map

Approach

Floor Area 5,000 ft2 20,000 ft2

No. Stories One Two

Roof Wood Framed Ins. Above Deck

Walls Wood Framed Mass

Foundation Unheated Slab Unheated Slab

WWR 20% & 40% 30% & 40%

Analysis

• Couple economics and energy savings

• Design of Experiment (DOE)

• Simplified Energy Regression Models– Heating, Cooling, SWH, Fans, AUX

• Iterative Solution Technique– 30% Energy Savings by Climate Zone

• Merge 5,000 ft2 and 20,000 ft2

LCC EconomicsINCREMENTAL ENERGY SAVINGS > INCREMENTAL FIRST COSTS (1)

HEATING + COOLING > INCREMENTAL FIRST COSTS (2)

(U1–U2)*Hcoef*HDD65*Ph*SR + (U1–U2)*Ccoef1*CDD50*Pc*SR > FC2–FC1 (3)

Hcoef*HDD65*Ph*SR + Ccoef1*CDD50*Pc*SR > (FC2–FC1) (4)

(U1–U2)

(FC2–FC1) = ΔFC/ΔU (5) (U1–U2)

[Hcoef*HDD65*Ph + Ccoef1*CDD50*Pc]*SR > ΔFC/ΔU (6)

dFC/dU

Opaque Envelope Components

05

101520253035404550

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70R

dFC

/dU

1-Attic

2-Above Deck

3-Single Rafter

4-Slab-Heated

5-Slab-Unheated

6-Mass Floor

7-Wood Joist Floor

8-Metal Frame Wall

9-Wood Frame Wall

10-Metal Joist Floor

12-Mass Walls

13-Below Grade Walls

14-Perlite Overlay

15-Metal Bldg Roof

16-Metal Bldg Wall

17-Sw inginhg Door

18-Non-Sw inging Door

Design of Experiment5,000 ft2

DOE-2 Simulations

100

150

200

250

300

350

400

450

500

550

600

0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000

HDD65

DO

E-2

To

tal E

ner

gy

- (M

MB

tu)

Base Advanced Ltg+Fan+SWH 30% Savings Target Ltg+Fan+SWH+OA Damper Controls Sensitivity Runs

Heating Regression Equation

HEATING = UoAo*24*HDD65/(AFUE*CF)

+ 1.08*ACH*VOLUME*24*HDD65/(AFUE*CF)

- WALLg*WWR*(N.Area-%)*SHGCn*PFn*SOLARn*%HEAT/CF

- WALLg*WWR*(E.Area-%)*SHGCe*PFe*SOLARe*%HEAT/CF

- WALLg*WWR*(S.Area-%)*SHGCs*PFs*SOLARs*%HEAT/CF

- WALLg*WWR*(W.Area-%)*SHGCw*PFw*SOLARw*%HEAT/CF

- (Lighting + Plugs + Fans)*%HEAT

- People*Sensible*55hr.wk*52wk/yr*%HEAT/CF

%HEAT = HDD65/(HDD65+CDD50)

where:

Heating5,000 ft2

-20

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

DOE-2 Heating (MMBtu)

Re

g.

Mo

de

l H

ea

tin

g (

MM

BT

U)

Cooling Regression Equation

COOLING = UoAo*24*CDD50/(EFF*CF)

+ 1.08*ACH*VOLUME*24*CDD50/(EFF*CF)

+ WALLg*WWR*(N.Area-%)*SHGCn*PFn*SOLARn*(1 - %HEAT)/CF

+ WALLg*WWR*(E.Area-%)*SHGCe*PFe*SOLARe*(1 - %HEAT)/CF

+ WALLg*WWR*(S.Area-%)*SHGCs*PFs*SOLARs*(1 – %HEAT)/CF

+ WALLg*WWR*(W.Area-%)*SHGCw*PFw*SOLARw*(1 – %HEAT)/CF

+ (Lighting + Plugs + Fans)*(1 – %HEAT)

+ People*Sensible*55hr.wk*52wk/yr*(1 – %HEAT)/CF

Cooling5,000 ft2

0.0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

0 10 20 30 40 50 60 70 80

Actual (MM btu)

Reg

ress

ion

(M

M b

tu)

Fans

FANS = INTERCEPT + (HDD65 + CDD50) + WWR + Ufen + PF + Ufen*WWR + Ufen*PF + (HDD65 + CDD50)*Ufen*PF*WWR

Fans5,000 ft2

0

10

20

30

40

50

60

70

0 10 20 30 40 50 60 70

DOE-2

Re

gre

ss

ion

Mo

de

l

O.A. Damper Energy Savings5,000 ft2 and 20,000 ft2

0

50

100

150

200

250

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

1000

0

1100

0

1200

0

1300

0

1400

0

1500

0

1600

0

HDD65

OA

Dam

per

En

erg

y S

avin

gs

- M

MB

tu

5000 ft2 5000 ft2 20,000 ft2

20,000 ft2 Linear (20,000 ft2) Linear (5000 ft2)

AUX5,000 ft2

y = -0.0235x + 1.8657

R2 = 0.9328

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 10 20 30 40 50 60 70 80

Tannual

AU

X

SWH5,000 ft2

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0

Actual (MM btu)

Reg

ress

ion

(M

M B

tu)

Figure 6 Total Energy

0

100

200

300

400

500

0 100 200 300 400 500

Actual (MM btu)

Regr

essi

on (M

M b

tu)

Regression Model Statistics

Scalar Ratio for 30% Savings

Bin City 5,000ft2 20,000ft2 Criteria1 Miami 10 8 102 Houston 12 8 123 Memphis 12-20-22 12-18-22 144 Albuquerque 10 14-18 145 Boise 10-14 8 146 Helena 12-16 8 127 Duluth 14 10 148 Fairbanks 12-20-26 10 20

Results

- Tables of Prescriptive Criteria for 8 Climate Zones- Same Format as 90.1- Roof – Surface reflectance/emittance (0.65 initial/0.86)- WWR – 20% to 40% max.- SHGC – North has separate criteria- Window Orientation – (Zones 1-5)- (An*SHGCn + As*SHGCs) > (Ae*SHGCe + Aw*SHGCw) - Exterior Sun Control – Projection Factors (Zones 1-5)- How-To-Use (EN1- to EN-42)- Appendix A (R-values and U-factors)

Conclusions

- Collaborative Effort

- Multiple Organizations

- Many Individuals

- Challenging

- Rewarding

Recommendations

• Encourage Participation in Future Projects

• Accept the Challenge

Acknowledgements

SP102 Members

Bing Liu - PNNL

Leonard Suharli - OC

Doug Walden - OC