DIAL GmbH 2012 Energy Efficiency Innovation Seminars

Embed Size (px)

Citation preview

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    1/17

    Energy Efficiency Calculations with DIALux

    October 26th, 2012

    Afra Lucas

    International BusinessDevelopment

    U.S. Representative Office

    DIAL GmbH

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    2/17

    Chicago

    Headquarters,Ldenscheid

    Mirano

    Istanbul Seoul

    Taiwan

    Center for Building Technology and Lighting Design Light planning

    Building technology

    Software

    Seminars

    DIAL GmbH

    www.dial.de

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    3/17

    Software development

    PlugIns

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    4/17

    DIALux serves asan advanced marketing tool

    for lighting manufacturers

    Individual catalogs and products presentation DIALuxis available free of charge

    More than half a Million users

    The DIALux Concept

    www.dial.de

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    5/17

    Advantages for manufacturers

    Constantly connects their products with their target audience

    Integration of products into the digital workflow of the lighting designprocess

    Provide customers with energy efficiency calculations that DIALuxenables you to do

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    6/17

    DIALuxFeatures

    DIALux is free of charge

    DIALux enables Architects and Engineers to make a lighting designbased on real product data

    Lighting calculation, energy optimization and presentation

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    7/17

    DIALuxFeatures

    DIALux offers an import and export to DXF, DWG or gbXML (BIM)

    Direct interface (STF) e.g. to Autodesk MEP, Revit, DDS, Allplan...

    Drag & Drop of required drawings, texts, diagrams or further information intoCAD application or any other programs like Word, Power Point, ... .

    DIALux works with PlugIns or simple IES files

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    8/17

    Lighting design process

    Required illuminance level and other normative factors (foot-candles,uniformity,)

    Minimum number of fittings

    Appealing luminaire arrangement

    Maximum maintenance cycles

    Minimum maintenance effort

    Using Design Software

    An interative process until the

    optimum products

    the correct number of products and

    maintenance values are found

    Checkingthe values

    Selectinglamps

    Selectingluminaires

    Placingluminaires

    Calculatingthe results

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    9/17

    Energetic optimization

    Estimation of energy demands in the lighting design phase

    Energetic optimization, finding the best product

    Software aided design and optimization

    Consideration of all parameters including daylight and control

    systems

    Calculating the energy costs

    Detection of the best solution

    Calculating the ROI

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    10/17

    Automatic calculation of LENI

    Proven method to calculate the energy demands for lighting isLENI LENI stands for Lighting Energy Numeric Indicator

    Most of the parameters needed for LENI calculation are already

    given in a 3D lighting design

    Some parameters have to be determined by the user, of course withthe help of software:

    Daylight time usage / non daylight time usage

    Availability of presence detection Availability of daylight control

    The calculation is done by software, the user just defines theparameters

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    11/17

    Location (lat., long.) ; Exterior obstruction, Building

    Rooms, Stories, Windows, Roof lights

    Luminaires, Total Power, Illuminance level

    Data available in the 3D design

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    12/17

    Daylit Zones

    On the right hand side the software displays the calculated daylit area

    Due to visual feedback, the designer selects a daylight control system forthis area and the lighting system therein

    In real time the new LENI value is calculated and it decreases from21.84 kWh/(m x a) to 18.06kWh/(m x a) = - 4%in this simple example

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    13/17

    Energetic optimization

    Shop lighting example:

    Attract people, draw the attention to products, invite to stay, highlight the

    productsgood color rendering, emphasize important products

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    14/17

    LED Spot10Beam25W 1600lm

    Tungsten Halogen10Beam95W 1150lm

    Identical light appearance

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    15/17

    Different power consumption

    LED

    LENI: 111kWh/(a x m)Energy: 7277 kWh/aCosts (7ct/kWh): $510

    TungstenLENI: 262kWh/(a x m)Energy: 17,576kWh/aCosts (7ct/kWh): $1230

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    16/17

    >69,000>101,000>329,000

    DIALux for you?

    Helpful insights and tips as well asinformation on the latest DIALuxupdates:

    DIALuxForum has over 11.000active members

    Networking forums related to

    DIALux:

    DIALuxe- newsletter frequentlydistributed

    new DIALuxPartner

    PlugIn & Update information

    DIALux is free of charge

    DIALuxhas open interfaces DIALuxsupports 26 languages

    Interface to Autodesk- Revit

  • 8/10/2019 DIAL GmbH 2012 Energy Efficiency Innovation Seminars

    17/17

    Thank you for your attention!

    For any question please contact:

    Afra Lucas

    Mail: [email protected].: 312 377 6126

    Web: www.dialux.com

    mailto:[email protected]://www.dialux.com/http://www.dialux.com/mailto:[email protected]