4
Engine Make & Model: Circuit Breaker Type: Fuel Tank Capacity: litres (US gal) Frequency: 50 Hz 60 Hz Fuel Consumption, Prime: l/hr (US gal/hr) Engine Speed: RPM Base Frame Type: Fuel Consumption, Standby : l/hr (US gal/hr) Heavy Duty Fabricated Steel Generator Model: Control Panel: EMCP 4.1 Output Ratings Generator Set Model - 3 Phase Standby* Prime* * Refer to ratings definitions on page 4. Ratings at power factor. Technical Data EU stage II emissions compliant. Image shown may not reflect actual package 250 (66.0) ) 8 . 6 ( 7 . 5 2 ) 7 . 5 ( 7 . 1 2 0 0 8 1 0 0 5 1 ) 5 . 7 ( 5 . 8 2 ) 3 . 6 ( 8 . 3 2 LC3114F 110.0 kVA 88.0 kW 100.0 kW 125.0 kVA 100.0 kVA 80.0 kW 90.4 kW 113.0 kVA 480/277 V, 60 Hz 400/230 V, 50 Hz 0.8 DE110E2 DIESEL GENERATOR SET Caterpillar Diesel Generator Range

DIESEL GENERATOR SET - Advanced Diesel … Item 50 Hz 60 Hz Motor Starting Capability* kVA Reactances: Per Unit Xd X'd X''d Reactances shown are applicable to prime ratings. *Based

  • Upload
    ngonhi

  • View
    223

  • Download
    4

Embed Size (px)

Citation preview

Engine Make & Model:

Circuit Breaker Type:

Fuel Tank Capacity: litres (US gal)

Frequency: 50 Hz 60 Hz

Fuel Consumption, Prime: l/hr (US gal/hr)

Engine Speed: RPM

Base Frame Type:

Fuel Consumption, Standby : l/hr (US gal/hr)

Heavy Duty Fabricated Steel

Generator Model:

Control Panel: EMCP 4.1

Output Ratings

Generator Set Model - 3 Phase Standby*Prime*

* Refer to ratings definitions on page 4.Ratings at power factor.

Technical Data

EU stage II emissions compliant.

Image shown may not reflect actual package

250 (66.0)

)8.6(7.52)7.5(7.12

00810051

)5.7(5.82)3.6(8.32

LC3114F

110.0 kVA

88.0 kW

100.0 kW

125.0 kVA

100.0 kVA

80.0 kW

90.4 kW

113.0 kVA480/277 V, 60 Hz

400/230 V, 50 Hz

0.8

DE110E2

DIESEL GENERATOR SETCaterpillar Diesel Generator Range

Air Filter Type:

Combustion Air Flow:

m³/min (cfm) -Standby:

-Prime:

Max. Combustion Air Intake

Restriction: kPa (in H2O)

Radiator Cooling Air Flow:

m³/min (cfm)

External Restriction to

Cooling Air Flow: Pa (in H2O)

Air System 60 Hz50 Hz

Moment of Inertia: kg m² (lb. in²)

Governing Type:

Governing Class:

Compression Ratio:

Displacement: l (cu.in)

Engine Electrical System:

-Voltage/Ground:

-Battery Charger Amps:

Weight: kg (lb) - Dry:

- Wet:

Cooling Method:

Bore/Stroke: mm (in)

Induction:

Manufacturer:

Model:

No. of Cylinders/Alignment:

Cycle:

Regenerative Power: kW-Prime:

-Standby:

BMEP: kPa (psi)

-Prime:

-Standby:

Gross Engine Power: kW (hp)Engine Speed: RPM

Oil Pan l (US gal):

Total Oil Capacity l (US gal):

Oil Filter Type:

Oil Type:

Cooling Method:

Prime

50 Hz

60 Hz

(based on diesel fuel with a speci�c gravity of 0.85 and conforming to BS2869, Class A2)

Recommended Fuel:

Fuel Consumption: l/hr (US gal/hr)

110%Load

75%Load

50%Load

100%Load

Fuel Filter Type:

Standby

50 Hz

60 Hz

Level: dB

Silencer System: kPa (in Hg)

Pressure Drop Across

Silencer Noise Reduction

Silencer Type:

Pressure: kPa (in. Hg)

Max. Allowable Back

-Prime:

m³/min (cfm) -Standby:

Exhaust Gas Flow:

-Prime:

-Standby:

Exhaust Gas Temperature: °C (°F)

Silencer Model & Quantity:Cooling System Capacity:

l (US gal)

Water Pump Type:

Heat Rejected to Water &

Lube Oil: kW (Btu/min)

-Standby:

-Prime:

-Prime:

kW (Btu/min) -Standby:

Heat Radiation to Room: Heat radiated from engine and alternator

Radiator Fan Load: kW (hp)

Cooling System 60 Hz50 Hz

Performance 60 Hz50 Hz

Fuel System

Exhaust System

Lubrication SystemPhysical Data

Engine Technical Data

60 Hz50 Hz

Class A2 Diesel or BSEN590

Cooling system designed to operate in ambient conditions up to 50°C(122 °F). Contact ADVANCED for power ratings at specific siteconditions

DIESEL GENERATOR SETCaterpillar Diesel Generator Range

8.0 (32.1)

187.8 (6632)

Replaceable Element

7.8 (275)6.3 (221)

7.8 (274)6.0 (212)

8.0 (32.1)

125 (0.5)125 (0.5)

244.2 (8624)

1.51 (5160)

Water

Electronic�

ISO�8528�G2

18.3:1

4.4 (268.5)

105.0 (4.1)/127.0 (5.0)

12/Negative

65500 (1102)

520 (1146)

Caterpillar

C4.44 / In Line

4 Stroke

Turbocharged Air To AirCharge Cooled

13.88.21702.0 (246.9) 1619.0 (234.8)

1781.0 (258.3)1873.0 (271.7)

106.8 (143.0)93.6 (126.0)103.0 (138.0) 117.5 (158.0)

18001500

Spin-On, Full Flow

8.0 (2.1)7.0 (1.8)

API CC/SE

Water

11.7 (3.1)14.1 (3.7)19.6 (5.2)25.7 (6.8)28.5 (7.5)

16.5 (4.4)21.7 (5.7)23.8 (6.3)

Replaceable Element

12.6 (3.3)18.0 (4.8)23.8 (6.3)15.2 (4.0)21.5 (5.7)28.5 (7.5)

EXSY1 (1)

3.56 (1.051)2.10 (0.620)

1722

15.0 (4.4)18.0 (5.3)

20.4 (720)16.3 (576)

18.4 (650)15.2 (537)

574 (1065)543 (1009)

517 (963)514 (957)

Industrial

50.7 (2883)

4.8 (6.4)

17.5 (4.6)17.5 (4.6)Centrifugal

64.0 (3640)

57.7 (3281)46.1 (2622)

17.7 (1007)15.3 (870)

15.7 (893)13.7 (779)

2.8 (3.8)

Data Item

50 Hz 60 Hz

Motor Starting Capability* kVA

Reactances: Per Unit

Xd

X'd

X''d

Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor and SHUNT excitation system.

Short Circuit Capacity** %

Generator Performance Data

��������

Model:

No. of Bearings:

Insulation Class:

Winding Pitch - Code:

Wires:

Ingress Protection Rating:

Excitation System:

AVR Model:

Overspeed: RPM

Voltage Regulation: (steady state)

Wave Form NEMA = TIF:

Wave Form IEC = THF:

Total Harmonic Content LL/LN:

Radio Interference:

Radiant Heat: kW (Btu/min)

-50 Hz:

-60 Hz:

Suppression is in line with European Standard EN61000-6

Physical Data Operating Data

** With optional Permanent Magnet generator.�

Generator Technical Data

DIESEL GENERATOR SETCaterpillar Diesel Generator Range

�����������

256 240 220 282 280 187 219 205 242

2.666 2.870 3.180 2.372 2.702 4.312 3.598 3.891 3.216

0.120 0.129 0.143 0.107 0.121 0.194 0.162 0.175 0.145

0.072 0.077 0.086 0.064 0.073 0.116 0.097 0.105 0.087

415/240V 400/230V230/115V200/115V

380/220V220/110V

220/127V 480/277V240/139V

380/220V220/110V

240/120V208/120V

230/115V 440/254V220/127V

300 300 300 300 300 300 300 300 300

LC3114F

1

H

2/3 - 6

12

IP23

SHUNT

R250 8.3 (472)

7.8 (444)

2.0%

2.0%

50

+/- 0.5%

2250

��

kWkVAkWkVA

Technical Data

Voltage50 Hz

Prime Standby

Standby Rating

������� ������� ����� ������� ���� ���� ���� �������� ��� �������������������� �������!�� "���#�������$�&������������������� �"���'���� ���� "������ ������ �����$� +���#�� ��������� �"� ��� ����"��������;������!<�!�!��<��#�����"������=�������"��������$

Prime Rating

Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload opeation cannot exceed 25 hours per year.

.Standard Reference Conditions

Note: Standard reference conditions 25°C (77°F) air inlet temp,100m (328ft) A.S.L. 30% relative humidity. Fuel consumption dataat full load with diesel fuel with specific gravity of 0.85 andconforming to BS2869: 1998, Class A2.

Definitions

kWkVAkWkVA

Voltage60 Hz

Prime Standby

Weights & Dimensions

Weights: kg (lb)

Net (+ lube oil)

Wet (+ lube oil & coolant)

Fuel, lube oil & coolant

Dimensions: mm (in)

Height

Width

Length

Documents

A full set of operation and maintenance manuals and circuit wiring diagrams.

Quality Standards

The equipment meets the following standards: IEC60034-1,IEC60034-22, ISO3046, ISO8528, NEMA MG 1-32, NEMA MG 1-33, 2004/108/EC, 2006/42/EC, 2006/95/EC.

General Data

Note: General con�guration not to be usedfor installation. See general dimensiondrawings for detail.

© 2015 ADVANCEDAll rights reserved.

14 Langthwaite Business Park, South Kirkby, Pontefract, West Yorkshire WF9 3AP, UK

www.adeltd.com

DIESEL GENERATOR SET

88.0110.0

88.0110.0

88.0110.0

88.0110.0

88.0110.0

88.0110.0

88.0110.0

80.0

80.0

80.0

80.0100.0

100.0

100.0

100.0

80.0100.0

100.0 80.0

200/115V

220/110V

220/127V

230/115V

380/220V

415/240V

400/230V

80.0100.0

100.0

100.0125.090.4113.0208/120V

100.0125.090.4113.0220/110V

100.0

100.0

100.0

100.0125.090.4113.0380/220V

100.0

100.0125.090.4113.0480/277V

125.0

125.0

125.0

125.0

125.090.4

90.4

90.4

90.4

90.4113.0

113.0

113.0

113.0

240/139V

440/254V

230/115V

240/120V

220/127V

113.0

1358 (2994)

1147 (2529)

1129 (2490)

1375 (54.1)

1120 (44.1)

2089 (82.2)

Caterpillar Diesel Generator Range