Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
■ SpecificationsDisplaySupply voltage
Input resolutionSampling periodFunctions
7-segment LCD with backlight
Refer to the E5 R datasheet (H122) for more information.
Display colors: Red, green, and orange Number of digits per display line: 5 Number of display lines: 3100 to 240 VAC, 24 VAC/VDC
50 ms per loop
Control typeControl methodTuningSetting relatedControl related
Communications
Standard, heating/cooling, position proportionalON/OFF, 2-PIDAutotuningSV limits, parameter protection, 8 banks
MV rate-of-change limit, MV when stopped, MV for error, SV tracking, special control (cascade, proportional)
RS-485 (CompoWay/F or MODBUS)
° ± ° ±1 digit max.±
:::::
::
Digital Controller for Control Applications Requiring Rapid Response and High Resolution.
The E5 R samples at 50 ms per loop for use with high-speed
response equipment, such as ceramic heaters. Measurements,
fluctuation detection, and logging for environmental testing equipment
are performed at a high resolution of 0.01°C.
The R in E5 R represents the two areas where this Digital Controller
excels - Rapid response and high Resolution.
Advanced & Sophisticated Digital Controller
E5AR96 x 96 x 95mm(W x H x D)
E5ER48 x 96 x 95mm(W x H x D)
Cat. No. H121-E1-01
Authorized Distributor:
Note: Specifications subject to change without notice.
OMRON CorporationIndustrial Automation CompanyMeasuring and Control DivisionShiokoji Horikawa, Shimogyo-ku,Kyoto, 600-8530 JapanTel: (81)75-344-7080/Fax: (81)75-344-7189
Regional Headquarters
OMRON EUROPE B.V.Wegalaan 67-69, NL-2132 JD HoofddorpThe NetherlandsTel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC1 East Commerce Drive, Schaumburg, IL 60173U.S.A.Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.83 Clemenceau Avenue, #11-01, UE Square,239920 SingaporeTel: (65)6835-3011/Fax: (65)6835-2711
OMRON CHINA CO., LTD. BEIJING OFFICERoom 1028, Office Building,Beijing Capital Times Square, No. 88 West Chang'an Road, Beijing, 100031 ChinaTel: (86)10-8391-3005/Fax: (86)10-8391-3688
Printed in Japan0403-1.5M (0403) (O)
Advanced Digital ControllerR a p i d R e s p o n s e & H i g h R e s o l u t i o n
E5 R Digital Controllers
Basic models1 loop for standardcontrol/1 loop forheating and cooling control
2 loops for standardcontrol/2 loops forheating and cooling control
1 loop for cascadecontrol
1 loop for standardcontrol with remote SP
1 loop for proportional control
1 loop for position-proportional control
4 alarm outputs, 2 event inputs, 2outputs (control/transfer)
4 alarm outputs, 6 event inputs,RS-485 communications, 4 out-puts (control/transfer)
Basic models1 loop for standard control/1 loop for heating and coolingcontrol
4 alarm outputs, 2 event inputs, 2 out-puts (control/transfer)
4 alarm outputs, 2 event inputs, RS-485 communications, 4 out-puts (control/transfer)
4 alarm ouputs, 4 event inputs,2 relay ouputs (open, closed)
4 alarm outputs, 4 event inputs,2 relay outputs (open, closed)RS-485 communications, 1 out-put (transfer)
4 alarm outputs, 4 event inputs,RS-485 communications, 4 out-puts (control/transfer)
2-loopmodels
2 loops for standard control/1 loop for heating and coolingcontrol
1 loop for cascadecontrol
1 loop for standard control with remote SP
1 loop for proportionalcontrol
4 alarm outputs, 4 event inputs, RS-485 communications, 2 out-puts (control/transfer)
2-loopmodels
4 loops for standardcontrol
2 loops for standardcontrol
2 loops for heating andcooling control
4 alarm outputs, 4 event inputs,RS-485 communications, 4 out-puts (control/transfer)
4-loopmodels
Position-proportionalcontrol models
1 loop for position-proportional control
4 alarm outputs, 4 event inputs, 2 relay outputs (open, closed)
4 alarm outputs, no event input, 2 relay outputs (open, closed)RS-485 communications, 1 out-put (transfer)
Position-proportionalcontrol models
E5AR
High-speed Sampling at 50 ms Resolution of 0.01°C with Platinum Resistance Thermometers
Stable control in high-speed response applications.
SV
High-speed sampling50 ms
Time
High-speed response:Only a few seconds are required to reach the set value.
sfer output
Analog input
Highresolutio0.01°C
ansfer/controlutput
der)
gh solution:43,000
.01°C
4 Loops in a Single Controller A Variety of I/O to Control with PLCs
PV1
PV1
MV1 MV2
MV2
MV3 MV4
PV2PV2
PV3 PV4
MV
PV
PID
PID
PIDPID PID PID
PID
Control 4 Loops with a Single Controller Cascade Control with a Single Controller
Proportional Control with a Single Controller
E5AR only
MV1=RSPSP
E5ARE5ER
E5ARE5ER
Proportional setting
Sim
RSP
PV
RS-485(CompoWay/F)
PV and SV datacan be shared easily.
CS/CJ Series, CQM1, or CPM2A
Event inputs
Multipoint analog inputs(4 inputs: IN1 to IN4) er
ts
Multipoint analog outputs(4 outputs: OUT1 to OUT 4)
Auxiliary output (alarms, etc.)
RapidResponse
HighResolution
Multi-loop
Applications
• Bonding equipment
• Evaporation equipment
• Coil winding equipment
Applications
• Sterilization equipment
• Food processing equipment
Applications
•manufacturing equipment(exposure and air conditioning)
• testing equipment••• Food processing equipment
Problem Solution
Problem Solution
Problem Solution
LCD with 3 Lines of 5 DigitsEasy Setting with Thermo Tools Support Software
Parameters
Easy Initial
Setup