20
Digital Multimeters Tektronix DMM4050 and DMM4040 Data Sheet DMM4050 Features & Benets Key Performance Specications 6.5 Digit Resolution Basic VDC Accuracy of up to 0.0024% (1 yr.) 100 mV to 1000 V Voltage Range, with up to 100 nV Resolution 100 μA to 10 A Current Range, with up to 100 pA Resolution 10 to 1 GRange, with up to 10 μΩ Resolution CAT I 1000 V, CAT II 600 V Available Functions and Features Volts, Ohms, and Amps Measurements Diode and Continuity Testing Frequency and Period Measurements Temperature and Capacitance Measurements (DMM4050) 2×4 Ohms 4-wire Measurement Technique TrendPlot™ Paperless Data Recorder Mode Measurement Statistics Histogram Mode Connectivity Front and Rear 2×4 Measurement Inputs USB Host Port on Front Panel for Easy Storage of Measurement Data and Instrument Settings RS-232, LAN, and GPIB Ports on Rear Panel for Quick PC Connectivity Includes USB to RS-232 Interface Adapter Cable Includes National Instrument’s LabVIEW SignalExpress™ TE Limited Edition for Connecting Your Bench 3-year Warranty

Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

  • Upload
    others

  • View
    31

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital MultimetersTektronix DMM4050 and DMM4040 Data Sheet

DMM4050

Features & BenefitsKey Performance Specifications

6.5 Digit ResolutionBasic VDC Accuracy of up to 0.0024% (1 yr.)100 mV to 1000 V Voltage Range, with up to 100 nV Resolution100 μA to 10 A Current Range, with up to 100 pA Resolution10 Ω to 1 GΩ Range, with up to 10 μΩ ResolutionCAT I 1000 V, CAT II 600 V

Available Functions and Features

Volts, Ohms, and Amps Measurements

Diode and Continuity Testing

Frequency and Period Measurements

Temperature and Capacitance Measurements (DMM4050)

2×4 Ohms 4-wire Measurement Technique

TrendPlot™ Paperless Data Recorder Mode

Measurement Statistics

Histogram Mode

Connectivity

Front and Rear 2×4 Measurement Inputs

USB Host Port on Front Panel for Easy Storage of Measurement Dataand Instrument Settings

RS-232, LAN, and GPIB Ports on Rear Panel for Quick PC Connectivity

Includes USB to RS-232 Interface Adapter Cable

Includes National Instrument’s LabVIEW SignalExpress™ TE LimitedEdition for Connecting Your Bench

3-year Warranty

Page 2: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

TrendPlot display.

Feature-Rich Tools for PrecisionMeasurementsAs the circuits in embedded system designs become more sophisticatedwith tighter tolerances, you must measure a multitude of differentparameters with a high degree of accuracy to validate your design. TheTektronix DMM4050 and DMM4040 6.5 digit bench multimeters pack manydifferent functions and analysis into one instrument, all with exceptionalprecision and performance.Typical multimeter measurements – volts, ohms, and amps – are made witha basic VDC accuracy of up to 0.0024%, and resolution of 100 pA and 10μΩ, ensuring you have the performance you need for today’s demandingdesigns. You can also use the DMM4050/4040 to measure frequency andperiod, and to perform continuity and diode tests. For additional flexibility,the DMM4050 offers temperature and capacitance measurements. Thisallows you to replace your temperature meter, capacitance meter, counter,continuity tester, and traditional DMM with one versatile instrument, savingbench space and cost.

Analyze Your Device with Graphical DisplayModesWith the unique dual display of the DMM4050/4040, you can measuretwo different parameters of the same signal from one test connection. Toreveal signal quality issues like drift, intermittent transients, and stability,you can view the data as a real-time trend plot or a histogram with theDMM4050/4040’s graphical display mode, or you can use measurementstatistics to track how signal parameters are changing over time.

TrendPlot™ Paperless Recorder ModeDepending on your test case, your signal parameters may changefrom instant to instant. By taking multiple measurements over minutes,hours, or days, you can quantify those changes. With TrendPlot™,you can graphically plot the trend of a measured value over time, fromshort time spans to extended periods of time. TrendPlot can be usedwith measurements like DC voltage, DC current, frequency, resistance,and temperature. AC voltage and current can be plotted as RMSmeasurements.

A sample of a Min/Max/Avg/SD Statistics Report.

Histogram display.

Measurement StatisticsWith integrated statistics processing, you can calculate both the averageand standard deviation of a measurement, as well as track the minimumand maximum measured values, with the push of a button. Statistics canbe performed on DC voltage, AC voltage, AC voltage in dB, DC current,AC current, resistance, capacitance, frequency, period, and temperaturemeasurements.

Histogram PlotsTo graphically see the average and standard deviation of a set ofmeasurements, you can use the histogram function to see the distribution ofmeasurement results.

Designed to Make YourWork EasierThe DMM4050/4040 multimeter is designed with the ease of use andfamiliar operation you expect from Tektronix.

Intuitive OperationDedicated front-panel buttons provide fast access to frequently usedfunctions and parameters, reducing setup time. You no longer need tosearch through software menus to find the function you need.

Easy Data Storage and PC ConnectivityA USB port on the front panel makes it easy to store measurement dataand instrument setups to a memory stick. Or connect to your PC with theLAN, RS-232, or GPIB port on the back panel. A USB to RS-232 interfaceadapter cable is included standard with the DMM4050/4040 to make it easyto connect to your PC’s USB port.

Simple and Accurate 4-wire MeasurementsPatented split terminal jacks for the 2×4 ohms function allow you to perform4-wire measurements using only two leads instead of four. Special test leadaccessories are available to enable you to establish the connection. You getexcellent resolution and accuracy plus the convenience and ease of using asingle pair of leads.

2 www.tektronix.com/dmm

Page 3: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

SignalExpress acquiring data from Tektronix DMM4050 and DPO3052.

Connect Your Bench for Intelligent DebugEasily capture, save, and analyze measurement results from yourmultimeter with the special Tektronix Edition of National Instrument’sLabVIEW SignalExpress™ software. Every DMM4050 and DMM4040 shipswith a free copy of the Limited Edition version of SignalExpress for basicinstrument control, data logging, and analysis. The optional ProfessionalEdition offers over 200 built-in functions that provide additional signalprocessing, advanced analysis, sweeping, limit testing, and user-definedstep capabilities.SignalExpress supports the range of Tektronix bench instruments*1,enabling you to connect your entire test bench. You can then access thefeature-rich tools packed into each instrument from one intuitive software

SignalExpress used to export DMM4050 data into Excel.

interface. This allows you to automate complex measurements requiringmultiple instruments, log data for an extended period of time, time correlatedata from multiple instruments, and easily capture and analyze your results,all from your PC. Only Tektronix offers a connected test bench of intelligentinstruments to simplify and speed debug of your complex design.

Performance You Can Count OnIn addition to industry-leading service and support, every DMM4050 andDMM4040 multimeter comes backed with a three-year standard warranty.*1 NI LabVIEW SignalExpress supports the following Tektronix instruments: MSO/DPO4000/3000/2000

Series oscilloscopes, TDS3000C/2000B/1000B Series oscilloscopes, AFG3000 Series arbitrary/functiongenerators, DMM4050/4040/4020 Series digital multimeters.

www.tektronix.com/dmm 3

Page 4: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

CharacteristicsGeneral Specifications

VoltageCharacteristic Description100 V Setting 90 V to 110 V120 V Setting 108 V to 132 V220 V Setting 198 V to 242 V240 V Setting 216 V to 264 VFrequency 47 Hz to 440 Hz. Automatically sensed at power-onPower Consumption 28 VA peak (12 Watt average)

DimensionsDimension mm in.Height 88 3.46Width 217 8.56Depth 297 11.7Weight kg lb.Net 3.6 8.0Shipping 5.0 11.0

DisplayVacuum Fluorescent Display, dot matrix

EnvironmentCharacteristic DescriptionTemperature

Operating 0 °C to 55 °CStorage –40 °C to 70 °CWarm Up 1 hour to full uncertainty specifications

Relative Humidity (noncondensing)Operating <90% (0 °C to 28 °C)

<80% (28 °C to 40 °C)<50% (40 °C to 55 °C)

Storage <95% (–40 °C to 70 °C)Altitude

Operating 2,000 metersStorage 12,000 meters

Vibration Complies with Mil-T-28800F Type III, Class 5 (Sine only)Safety Designed to comply with IEC 61010-1:2000-1, UL

61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/ CAT II 600 V

EMC Designed to comply with IEC 61326-1:2000-11 (EMC)when used with shielded communications cables. Thismeter has shown susceptibility to radiated frequenciesgreater than 1 V/m from 250 to 450 MHz

TriggeringCharacteristic DescriptionSamples per Trigger 1 to 50,000Trigger Delay 0 s to 3600 s; in 10 μs incrementsExternal Trigger Delay <1 msExternal Trigger Jitter <500 μsTrigger Input TTL LevelsTrigger Output 5 V max (open collector)

MemoryModel DescriptionDMM4050/4040 10,000 measurements, internal, and up to 2 Gigabyte

capacity with USB memory module (availableseparately) through front-panel USB port

Math FunctionsZero, dBm, dB, MX+B, Offset, DCV ratio and TrendPlot, Histogram, Statistics(min/max/average/standard deviation), and Limit Test

ElectricalCharacteristic DescriptionInput Protection 1000 V all rangesOverrange 20% on all ranges except 1000 VDC, 1000 VAC, Diode,

and 10 A ranges

Remote InterfacesRS-232C, DTE 9-pin, 1200 to 230400 baud (RS-232C to USB cable availableto connect the meter to a PC USB port) IEEE 488.2.LAN and “Ethernet 10/100Base-T with DHCP (for IP address) option”.

WarrantyThree years

4 www.tektronix.com/dmm

Page 5: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

Electrical Specifications

DC Voltage SpecificationsAccuracy specifications are valid for 6½ digit resolution mode after at least a 1 hourwarm-up with Auto Zero enabled.24-hour specifications are relative to calibration standards and assume a controlledelectromagnetic environment per EN 61326-1:2000-11.

Characteristic DescriptionMaximum Input 1000 V on any rangeCommon ModeRejection

140 dB at 50 or 60 Hz ±0.1% (1 kΩ unbalance)

Normal Mode Rejection 60 dB for NPLC of 1 or greater with analog filter off andpower line frequency ±0.1%100 dB for NPLC of 1 or greater with analog filter on andpower line frequency ±0.1%

Measurement Method Multiramp A/DA/D Linearity 0.0002% of measurement + 0.0001% of rangeInput Bias Current <30 pA at 25 °CAuto-zero Off Operation Following instrument warm-up at calibration temperature

±1 °C and less than 10 minutes, add error: 0.0002%range additional error +5 μV

Analog Filter When using the analog filter, specifications are relativeto within one hour of using the ZERO function for thatrange and NPLC setting

DC Ratio Accuracy is ±(Input accuracy + Reference accuracy),where Input accuracy = DC Voltage accuracy for the HIto LO Input (in ppm of the Input voltage), and Referenceaccuracy = DC Voltage accuracy for the HI to LO(Sense) Reference (in ppm of the Reference voltage)

Settling Considerations Measurement settling times are affected by sourceimpedance, cable dielectric characteristics, and inputsignal changes

Input CharacteristicsResolutionRange Resolution

4½ Digits 5½ Digits 6½ DigitsInput Impedance

100 mV 100.0000 mV 10 μV 1 μV 100 nV 10 MΩ or >10 GΩ*2

1 V 1.000000 V 100 μV 10 μV 1 μV 10 MΩ or >10 GΩ*2

10 V 10.00000 V 1 mV 100 μV 10 μV 10 MΩ or >10 GΩ*2

100 V 100.0000 V 10 mV 1 mV 100 μV 10 MΩ ±1%1000 V 1,000.000 V 100 mV 10 mV 1 mV 10 MΩ ±1%*2 Inputs beyond ±14 V are clamped through 200 kΩ typical. 10 MΩ is default input impedance.

www.tektronix.com/dmm 5

Page 6: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

DMM4050 AccuracyAccuracy is given as ±(% measurement + % of range)Range 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)Temperature Coefficient/°C

Outside 18 to 28 °C100 mV 0.0025 + 0.003 0.0025 + 0.0035 0.0037 + 0.0035 0.0005 + 0.00051 V 0.0018 + 0.0006 0.0018 + 0.0007 0.0025 + 0.0007 0.0005 + 0.000110 V 0.0013 + 0.0004 0.0018 + 0.0005 0.0024 + 0.0005 0.0005 + 0.0001100 V 0.0018 + 0.0006 0.0027 + 0.0006 0.0038 + 0.0006 0.0005 + 0.00011000 V 0.0018 + 0.0006 0.0031 + 0.001 0.0041 + 0.001 0.0005 + 0.0001

DMM4040 AccuracyAccuracy is given as ±(% measurement + % of range)Range 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)Temperature Coefficient/°C

Outside 18 to 28 °C100 mV 0.003 + 0.003 0.004 + 0.0035 0.005 + 0.0035 0.0005 + 0.00051 V 0.002 + 0.0006 0.003 + 0.0007 0.004 + 0.0007 0.0005 + 0.000110 V 0.0015 + 0.0004 0.002 + 0.0005 0.0035 + 0.0005 0.0005 + 0.0001100 V 0.002 + 0.0006 0.0035 + 0.0006 0.0045 + 0.0006 0.0005 + 0.00011000 V 0.002 + 0.0006 0.0035 + 0.0010 0.0045 + 0.0010 0.0005 + 0.0001

Additional ErrorsDigits NPLC Additional NPLC Noise Error6½ 100 0% of range6½ 10 0% of range5½ 1 0.001% of range5½ 0.2 0.0025% of range ±12 μV4½ 0.02 0.017% of range ±17 μV

6 www.tektronix.com/dmm

Page 7: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

AC Voltage SpecificationsAC Voltage specifications are for AC sinewave signals >5% of range. For inputs from1% to 5% of range and <50 kHz, add an additional error of 0.1% of range, and for50 kHz to 100 kHz, add 0.13% of range.

Characteristic DescriptionMaximum Input 1000 VRMS or 1414 V peak or 8 × 107 Volts-Hertz product

(whichever is less) for any rangeMeasurement Method AC-coupled true RMS. Measures the AC component of

input with up to 1000 VDC bias on any rangeAC Filter Bandwidth

Slow 3 Hz - 300 kHzMedium 20 Hz - 300 kHzFast 200 Hz - 300 kHz

Common ModeRejection

70 dB at 50 Hz or 60 Hz ±0.1% (1 kΩ unbalance)

Maximum Crest Factor 5:1 at Full ScaleAdditional Crest FactorErrors (<100 Hz)

Crest factor 1-2, 0.05% of full scaleCrest factor 2-3, 0.2% of full scaleCrest factor 3-4, 0.4% of full scaleCrest factor 4-5, 0.5% of full scaleOnly applies for non-sinusoid signals

Input CharacteristicsResolutionRange Resolution

4½ Digits 5½ Digits 6½ DigitsInput Impedance

100 mV 100.0000 mV 10 μV 1 μV 100 nV1 V 1.000000 V 100 μV 10 μV 1 μV10 V 10.00000 V 1 mV 100 μV 10 μV100 V 100.0000 V 10 mV 1 mV 100 μV1000 V 1,000.000 V 100 mV 10 mV 1 mV

1 MΩ ±2% shunted by<100 pf

www.tektronix.com/dmm 7

Page 8: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

DMM4050/4040 AccuracyAccuracy is given as ±(% measurement + % of range)Range Frequency 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)TemperatureCoefficient/°C

Outside 18 to 28 °C3 - 5 Hz 1.0 + 0.03 1.0 + 0.04 1.0 + 0.04 0.1 + 0.0045 - 10 Hz 0.35 + 0.03 0.35 + 0.04 0.35 + 0.04 0.035 + 0.004

10 Hz - 20 kHz 0.04 + 0.03 0.05 + 0.04 0.06 + 0.04 0.005 + 0.00420 - 50 kHz 0.1 + 0.05 0.11 + 0.05 0.12 + 0.05 0.011 + 0.00550 - 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008

100 mV

100 - 300 kHz*3 4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.20 + 0.023 - 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.0035 - 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003

10 Hz - 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.00320 - 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.00550 - 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008

1 V

100 - 300 kHz*3 4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.023 - 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.0035 - 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003

10 Hz - 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.00320 - 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.00550 - 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008

10 V

100 - 300 kHz*3 4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.023 - 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.0035 - 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003

10 Hz - 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.00320 - 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.00550 - 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008

100 V

100 - 300 kHz*3 4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.023 - 5 Hz 1.0 + 0.015 1.0 + 0.0225 1.0 + 0.0225 0.1 + 0.002255 - 10 Hz 0.35 + 0.015 0.35 + 0.0225 0.35 + 0.0225 0.035 + 0.00225

10 Hz - 20 kHz 0.04 + 0.015 0.05 + 0.0225 0.06 + 0.0225 0.005 + 0.0022520 - 50 kHz 0.1 + 0.03 0.11 + 0.0375 0.12 + 0.0375 0.011 + 0.00375

50 - 100 kHz*4 0.55 + 0.06 0.6 + 0.06 0.6 + 0.06 0.06 + 0.006

1000 V

100 - 300 kHz*3, 4 4.0 + 0.375 4.0 + 0.375 4.0 + 0.375 0.2 + 0.015*3 Typically 30% reading error at 1 MHz.*4 1000 V range is limited to 8 × 107 Volt-Hertz.

Additional Low Frequency ErrorsError is stated as % of reading.

AC FilterFrequency3 Hz (Slow) 20 Hz (Medium) 200 Hz (Fast)

10 - 20 Hz 0 0.25 —20 - 40 Hz 0 0.02 —40 - 100 Hz 0 0.01 0.55100 - 200 Hz 0 0 0.2200 Hz - 1 kHz 0 0 0.02>1 kHz 0 0 0

8 www.tektronix.com/dmm

Page 9: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

ResistanceSpecifications are for 4-wire resistance function, 2 × 4-wire resistance, or 2-wireresistance with zero. If zero is not used, add 0.2 Ω for 2-wire resistance plus leadresistance, and add 20 mΩ for 2 × 4-wire resistance function.

Characteristic DescriptionMeasurement Method Current source referenced to LO inputMax Lead Resistance(4-wire ohms)

10% of range per lead for 10 Ω, 100 Ω, 1 kΩ ranges.1 kΩ per lead on all other ranges

Input Protection 1000 V on all rangesCommon ModeRejection

140 dB at 50 or 60 Hz ±0.1% (1 kΩ unbalance)

Normal Mode Rejection 60 dB for NPLC of 1 or greater with analog filter off andpower line frequency ±0.1%100 dB for NPLC of 1 or greater with analog filter on andpower line frequency ±0.1%

Analog Filter When using the analog filter, specifications are relativeto within one hour of using the ZERO function for thatrange and NPLC setting

Input CharacteristicsResolutionRange Resolution

4½ Digits 5½ Digits 6½ DigitsSource Current

10 Ω 10.00000 Ω 1 mΩ 100 μΩ 10 μΩ 5 mA / 13 V100 Ω 100.0000 Ω 10 mΩ 1 mΩ 100 μΩ 1 mA / 6 V1 kΩ 1.000000 kΩ 100 mΩ 10 mΩ 1 mΩ 1 mA / 6 V10 kΩ 10.00000 kΩ 1 Ω 100 mΩ 10 mΩ 100 μA / 6 V100 kΩ 100.0000 kΩ 10 Ω 1 Ω 100 mΩ 100 μA / 13 V1 MΩ 1.000000 MΩ 100 Ω 10 Ω 1 Ω 10 μA / 13 V10 MΩ 10.00000 MΩ 1 kΩ 100 Ω 10 Ω 1 μA / 13 V100 MΩ 100.0000 MΩ 10 kΩ 1 kΩ 100 Ω 1 μA || 10 MΩ / 10 V1.0 GΩ 1.000000 GΩ 100 kΩ 10 kΩ 1 kΩ 1 μA || 10 MΩ / 10 V

DMM4050/4040 AccuracyAccuracy is given as ±(% measurement + % of range)Range 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)Temperature Coefficient/°C

Outside 18 to 28 °C10 Ω 0.003 + 0.01 0.008 + 0.03 0.01+ 0.03 0.0006 + 0.0005100 Ω 0.003 + 0.003 0.008 + 0.004 0.01 + 0.004 0.0006 + 0.00051 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.000110 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001100 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.00011 MΩ 0.002 + 0.001 0.008 + 0.001 0.01 + 0.001 0.001 + 0.000210 MΩ 0.015 + 0.001 0.02 + 0.001 0.04 + 0.001 0.003 + 0.0004100 MΩ 0.3 + 0.01 0.8 + 0.01 0.8 + 0.01 0.15 + 0.00021 GΩ 1.0 + 0.01 1.5 + 0.01 2.0 + 0.01 0.6 + 0.0002

Additional Ohms ErrorsDigits NPLC Additional NPLC Noise Error6½ 100 0% of range6½ 10 0% of range5½ 1 0.001% of range5½ 0.2 0.003% of range ±7 mΩ4½ 0.02 0.017% of range ±15 mΩ

www.tektronix.com/dmm 9

Page 10: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

DC Current

Characteristic DescriptionInput Protection Tool-accessible 11 A / 1000 V and 440 mA / 1000 V

fuses, limits of 400 mA continuous 550 mA for 2 minuteson, 1 minute off

Common ModeRejection

140 dB at 50 or 60 Hz ±0.1% (1 kΩ unbalance)

Normal Mode Rejection 60 dB for NPLC of 1 or greater with analog filter off andpower line frequency ±0.1%100 dB for NPLC of 1 or greater with analog filter on andpower line frequency ±0.1%

Analog Filter When using the analog filter, specifications are relativeto within one hour of using the ZERO function for thatrange and NPLC setting

Input CharacteristicsResolutionRange Resolution

4½ Digits 5½ Digits 6½ DigitsShunt Resistance

(Ohms)Burden Voltage

100 μA 100.0000 μA 10 nA 1 nA 100 pA 100 Ω <0.015 V1 mA 1.000000 mA 100 nA 10 nA 1 nA 100 Ω <0.15 V10 mA 10.00000 mA 1 μA 100 nA 10 nA 1 Ω <0.025 V100 mA 100.0000 mA 10 μA 1 μA 100 nA 1 Ω <0.25 V400 mA*7 400.000 mA 100 μA 10 μA 1 μA 1 Ω <0.50 V1 A*6 1.000000 A 100 μA 10 μA 1 μA 0.01 Ω <0.05 V3 A*5 3.00000 A 1 mA 100 μA 10 μA 0.01 Ω <0.15 V10 A 10.00000 A 1 mA 100 μA 10 μA 0.01 Ω <0.5 V*5 Part of 10 A range.*6 Available on the front-panel terminal only.*7 400 mA available in software version 2.0 or greater only. 400 mA continuously; 550 mA for 2 minutes on, 1 minute off.

DMM4050/4040 AccuracyAccuracy is given as ±(% measurement + % of range)Range 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)Temperature Coefficient/°C

Outside 18 to 28 °C100 μA 0.01 + 0.02 0.04 + 0.025 0.05 + 0.025 0.002 + 0.0031 mA 0.007 + 0.005 0.030 + 0.005 0.05 + 0.005 0.002 + 0.000510 mA 0.007 + 0.02 0.03 + 0.02 0.05 + 0.02 0.002 + 0.002100 mA 0.01 + 0.004 0.03 + 0.005 0.05 + 0.005 0.002 + 0.0005400 mA*7 0.03 + 0.004 0.04 + 0.005 0.05 + 0.005 0.005 + 0.00051 A*6 0.03 + 0.02 0.04 + 0.02 0.05 + 0.02 0.005 + 0.0013 A*5, 6 0.05 + 0.02 0.08 + 0.02 0.1 + 0.02 0.005 + 0.00210 A*6 0.1 + 0.008 0.12 + 0.008 0.15 + 0.008 0.005 + 0.0008*5 Part of 10 A range.*6 Available on the front-panel terminal only.*7 400 mA available in software version 2.0 or greater only. 400 mA continuously; 550 mA for 2 minutes on, 1 minute off.

Additional Current ErrorsDigits NPLC Additional NPLC Noise Error

for 1 mA, 100 mA, 400 mA,3 A, and 10 A

Additional NPLC Noise Error for100 μA, 10 mA, 1 A

6½ 100 0% of range 0% of range6½ 10 0% of range 0% of range5½ 1 0.001% of range 0.01% of range5½ 0.2 0.11% of range ±4 μA 0.11% of range ±4 μA4½ 0.02 0.04% of range ±4 μA 0.28% of range ±4 μA

10 www.tektronix.com/dmm

Page 11: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

AC CurrentThe following AC current specifications are for sinusoidal signals with amplitudesgreater than 5% of range. For inputs from 1% to 5% of range, add an additionalerror of 0.1% of range.

Characteristic DescriptionInput Protection Tool-accessible 11 A / 1000 V and 440 mA / 1000 V

fuses, limits of 400 mA continuous 550 mA for 2 minuteson, 1 minute off

Measurement Method AC-coupled true RMS, DC-coupled to the fuse and shunt(no blocking capacitor)

AC Filter BandwidthSlow 3 Hz to 10 kHzMedium 20 Hz to 10 kHzFast 200 Hz to 10 kHz

Maximum Crest Factor 5:1 at Full ScaleAdditional Crest FactorErrors (<100 Hz)

Crest factor 1-2, 0.05% of full scaleCrest factor 2-3, 0.2% of full scaleCrest factor 3-4, 0.4% of full scaleCrest factor 4-5, 0.5% of full scaleOnly applies to non-sinusoid signals

Input CharacteristicsResolutionRange Resolution

4½ Digits 5½ Digits 6½ DigitsShunt Resistance

(Ohms)Burden Voltage

100 μA 100.0000 μA 10 nA 1 nA 100 pA 100 Ω <0.015 V1 mA 1.000000 mA 100 nA 10 nA 1 nA 100 Ω <0.15 V10 mA 10.00000 mA 1 μA 100 nA 10 nA 1 Ω <0.025 V100 mA 100.0000 mA 10 μA 1 μA 100 nA 1 Ω <0.25 V400 mA*9 400.000 mA 100 μA 10 μA 1 μA 1 Ω <0.50 V1 A*8 1.000000 A 100 μA 10 μA 1 μA 0.01 Ω <0.05 V3 A*5, 8 3.00000 A 1 mA 100 μA 10 μA 0.01 Ω <0.05 V10 A*8 10.00000 A 1 mA 100 μA 10 μA 0.01 Ω <0.5 V*5 Part of 10 A range.*8 Available at front-panel connectors only.*9 400 mA available in software version 1.0.700.18 or greater only. 400 mA continuously; 550 mA for 2 minutes on, 1 minute off; maximum crest factor 3:1 at 400 mA.

www.tektronix.com/dmm 11

Page 12: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

DMM4050/4040 AccuracyAccuracy is given as ±(% measurement + % of range)Range Frequency 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)TemperatureCoefficient/°C

Outside 18 to 28 °C3 - 5 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.2 + 0.0065 - 10 Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.1 + 0.006

10 Hz - 5 kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006

100 μA

5 - 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.0063 - 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.0065 - 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006

10 Hz - 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006

1 mA

5 - 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.0063 - 5 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.2 + 0.0065 - 10 Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.1 + 0.006

10 Hz - 5 kHz 0.15 + 0.06 0.15 + 0.06 0.15+ 0.06 0.015 + 0.006

10 mA

5 - 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.0063 - 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.0065 - 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006

10 Hz - 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006

100 mA

5 - 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.0063 - 5 Hz 1.0 + 0.1 1.0 + 0.1 1.0 + 0.1 0.1 + 0.0065 - 10 Hz 0.3 + 0.1 0.3 + 0.1 0.3 + 0.1 0.035 + 0.006

10 Hz - 5 kHz 0.1 + 0.1 0.1 + 0.1 0.1 + 0.1 0.015 + 0.006

400 mA*7

5 - 10 kHz 0.2 + 0.7 0.2 + 0.7 0.2 + 0.7 0.03 + 0.0063 - 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.0065 - 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006

10 Hz - 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006

1 A*6

5 - 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.0063 - 5 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.1 + 0.0065 - 10 Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.035 + 0.006

10 Hz - 5 kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006

3 A*5, 6

5 - 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.0063 - 5 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.1 + 0.0065 - 10 Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.035 + 0.006

10 Hz - 5 kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006

10 A*6

5 - 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006*5 Part of 10 A range.*6 Available on the front-panel terminal only.*7 400 mA available in software version 2.0 or greater only. 400 mA continuously; 550 mA for 2 minutes on, 1 minute off.

Additional Low-frequency ErrorsError is stated as % of reading.

AC FilterFrequency3 Hz (Slow) 20 Hz (Medium) 200 Hz (Fast)

10 - 20 Hz 0 0.25 —20 - 40 Hz 0 0.02 —40 - 100 Hz 0 0.01 0.55100 - 200 Hz 0 0 0.2200 Hz - 1 kHz 0 0 0.02>1 kHz 0 0 0

12 www.tektronix.com/dmm

Page 13: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

Frequency

Characteristic Description

Gate Time Programmable to 1 s, 100 ms, and 10 msMeasurementMethod

Flexible counting technique. AC-coupled input usingthe AC voltage measurement function

SettlingConsiderations

When measuring frequency or period after a DCoffset voltage change, errors may occur. For themost accurate measurement, wait up to 1 second forthe input blocking capacitor to settle

MeasurementConsiderations

To minimize measurement errors, shield inputsfrom external noise when measuring low-voltage,low-frequency signals

DMM4050/4040 AccuracyAccuracy is given as ± % measurementRange Frequency 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)TemperatureCoefficient/°C

Outside 18 to 28 °C3 - 5 Hz 0.1 0.1 0.1 0.0055 - 10 Hz 0.05 0.05 0.05 0.00510 - 40 Hz 0.03 0.03 0.03 0.001

40 Hz - 300 kHz 0.006 0.01 0.01 0.001

100 mV to 1000 V*10, 11

300 kHz - 1 MHz 0.006 0.01 0.01 0.001*10 Limited to 8 × 107 Volt-Hertz*11 Input >100 mV. For 10 - 100 mV, multiply percent measurement error by 10.

Gate Time vs. ResolutionGate Time Resolution0.01 5½0.1 6½1.0 6½

Additional Low-frequency ErrorsError stated as percent of measurement for inputs >100 mV. For 10 - 100 mV,multiply percent by 10.

NPLCFrequency6½ 5½ 4½

3 - 5 Hz 0 0.12 0.125 - 10 Hz 0 0.17 0.1710 - 40 Hz 0 0.2 0.240 - 100 Hz 0 0.06 0.21100 - 300 Hz 0 0.03 0.21300 Hz - 1 kHz 0 0.01 0.07>1 kHz 0 0 0.02

www.tektronix.com/dmm 13

Page 14: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

Capacitance (DMM4050 Only)Accuracy is stated as ±(% of measurement + % of range)Range Resolution 1 Year Accuracy*12

(23 °C ±5 °C)Temperature Coefficient/°C

Outside 18 to 28 °C1 nF 1 pF 2% ±2.5% 0.05 + 0.0510 nF 10 pF 1% ±0.5% 0.05 + 0.01100 nF 100 pF 1% ±0.5% 0.01 + 0.011 μF 1 nF 1% ±0.5% 0.01 + 0.0110 μF 10 nF 1% ±0.5% 0.01 + 0.01100 μF 100 nF 1% ±0.5% 0.01 + 0.011 mF 1 μF 1% ±0.5% 0.01 + 0.0110 mF 10 μF 1% ±0.5% 0.01 + 0.01100 mF 100 μF 4% ±0.2% 0.05 + 0.05*12 Stated accuracy is attained when Zero function is used.

Temperature (DMM4050 only)Test Current: 1 mAAccuracy is stated as ± °C and is based on a Platinum RT100 (DIN IEC 751, 385 type) RTD with less than 10 Ω lead resistance. The accuracy listed in the table below are validonly when using the 4-wire RTD measurement function. Specifications do not include probe accuracy, which must be added.

AccuracyRange Resolution90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)

Temperature Coefficient/°COutside 18 to 28 °C

–200 °C 0.001 °C 0.06 0.09 0.0025–100 °C 0.001 °C 0.05 0.08 0.0020 °C 0.001 °C 0.04 0.06 0.002100 °C 0.001 °C 0.05 0.08 0.002300 °C 0.001 °C 0.1 0.12 0.002600 °C 0.001 °C 0.18 0.22 0.002

Additional ErrorsDigits NPLC Additional NPLC Noise Error6½ 100 0 °C6½ 10 0 °C5½ 1 0.03 °C5½ 0.2 0.12 °C4½ 0.02 0.6 °C

14 www.tektronix.com/dmm

Page 15: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

Continuity

Characteristic DescriptionContinuity Threshold Selectable between 1 Ω and 1000 ΩTest Current 1 mAResponse Time 300 S/s with audible tone

Accuracy is given as ±(% measurements + % of range)Range 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)TemperatureCoefficient/°COutside 18to 28 °C

1000.0 Ω 0.002 + 0.01 0.008 + 0.02 0.01 + 0.02 0.001 + 0.002

Diode Test

Characteristic DescriptionTest Current 100 μA or 1 mAResponse Time 300 S/s with audible tone

Accuracy is given as ±(% measurements + % of range)Range 24 Hour

(23 °C ±1 °C)90 Days

(23 °C ±5 °C)1 Year

(23 °C ±5 °C)TemperatureCoefficient/°COutside 18to 28 °C

5.0000 V 0.002 + 0.002 0.008 + 0.002 0.01 + 0.002 0.001 + 0.00210.0000 V 0.002 + 0.001 0.008 + 0.002 0.01 + 0.002 0.001 + 0.002

Measurement Rates (IEEE488*16)Measurements/Second*13Function Digits Setting Integration Time

60 Hz (50 Hz) DMM4040 DMM40506½ 100 NPLC 1.67 (2) s 0.6 (0.5) 0.6 (0.5)6½ 10 NPLC 167 (200) ms 6 (5) 6 (5)5½ 1 NPLC 16.7 (20) ms 60 (50) 60 (50)5½ 0.2 NPLC 3.3 ms 270 270

DC Volts, DC Current, andResistance

4½ 0.02 NPLC 500 μs 995 9956½ 3 Hz 0.47 0.476½ 20 Hz 1.64 1.64

AC Voltage and ACCurrent*14

6½ 200 Hz*15 4.5 4.56½ 1 s 1 15½ 100 ms 9.8 9.8

Frequency and Period

4½ 10 ms 80 80Capacitance 6½ NA 2*13 Typical measurement rates with auto-zero off, delay = 0, display off, auto range off and math off.*14 Maximum measurement rates for 0.01% of AC step. When DC input varies, additional settling delay is required.*15 For remote operation or external trigger using default settling delay.*16 Speeds available in OutG SW 1.0.700.18 or higher. Note that the measurement rates for RS232 can vary depending on the baud rate chosen. If the baud rate selected is 115,200, the maximum measurement rate is

711 measurements. The LAN bus has a maximum measurement rate of 963 measurements.

www.tektronix.com/dmm 15

Page 16: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

Ordering Information

ModelsModel DescriptionDMM4040 6.5 Digit MultimeterDMM4050 6.5 Digit Multimeter

DMM4050/4040 Includes: Meter, TL710 test leads, line cord, spare line fuse,statement of cal practices, Warranty statement, Safety and Installation Guide,CD-ROM with user manual (English, French, Italian, German, Spanish, SimplifiedChinese, Traditional Chinese, Korean, Russian, Japanese), RS-232 to USB AdapterCable, National Instruments LabVIEW SignalExpress™ Tektronix Edition, LimitedEdition Software.

Please specify power plug when ordering.

Instrument Options

Power Plug OptionsOption DescriptionOpt. A0 North AmericaOpt. A1 Universal EuroOpt. A2 United KingdomOpt. A3 AustraliaOpt. A5 SwitzerlandOpt. A6 JapanOpt. A10 ChinaOpt. A11 IndiaOpt. E1 Euro and UK power cords

Service Options*17Option DescriptionOpt. CA1 Provides a single calibration event or coverage for the

designated calibration interval, whichever comes firstOpt. C3 Calibration Service 3 YearsOpt. C5 Calibration Service 5 YearsOpt. D1 Calibration Data ReportOpt. R5 Repair Service 5 Years (including warranty)*17 Test Leads and accessories are not covered by the DMM warranty and Service Offerings. Refer to the

datasheet of each Test Lead and accessory model for its unique warranty and calibration terms.

Recommended Accessories and SoftwareAccessory DescriptionCalibration Manual 077-0362-xxProgrammer’s Manual 077-0363-xxTP750 100 Ω RTD Temperature Probe (DMM4050 only)196-3520-xx Premium Test Leads (replacement/spare for TL710)TL705 2×4 Wire Ohm 1000 V Precision Test LeadTL725 2×4 Wire Ohm SMD Test TweezersAC4000 Soft Transit CaseHCTEK4321 Hard Carrying CaseY8846S Single Rackmount KitY8846D Dual Rackmount Kit013-0369-xx Calibration Fixture 4-terminal shortSIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software –

Full Version

Product(s) are manufactured in ISO registered facilities.

Product(s) complies with IEEE Standard 488.1-1987 and RS-232C.

16 www.tektronix.com/dmm

Page 17: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

www.tektronix.com/dmm 17

Page 18: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet

18 www.tektronix.com/dmm

Page 19: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Digital Multimeters — Tektronix DMM4050 and DMM4040

www.tektronix.com/dmm 19

Page 20: Digital Multimeters - DMM4050, DMM4040instrucamp.com.br/dropbox/6cb04a60ae8e9ce15782ccac... · Digital Multimeters TektronixDMM4050andDMM4040DataSheet DMM4050 Features &Benefits

Data Sheet Contact Tektronix:ASEAN / Australasia (65) 6356 3900

Austria +41 52 675 3777

Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777

Belgium 07 81 60166

Brazil +55 (11) 3759-7627

Canada 1 (800) 661-5625

Central East Europe, Ukraine, and the Baltics +41 52 675 3777

Central Europe & Greece +41 52 675 3777

Denmark +45 80 88 1401

Finland +41 52 675 3777

France +33 (0) 1 69 86 81 81

Germany +49 (221) 94 77 400

Hong Kong (852) 2585-6688

India (91) 80-42922600

Italy +39 (02) 25086 1

Japan 81 (3) 6714-3010

Luxembourg +44 (0) 1344 392400

Mexico, Central/South America & Caribbean 52 (55) 54247900

Middle East, Asia, and North Africa +41 52 675 3777

The Netherlands 090 02 021797

Norway 800 16098

People’s Republic of China 86 (10) 6235 1230

Poland +41 52 675 3777

Portugal 80 08 12370

Republic of Korea 82 (2) 6917-5000

Russia & CIS +7 (495) 7484900

South Africa +27 11 206 8360

Spain (+34) 901 988 054

Sweden 020 08 80371

Switzerland +41 52 675 3777

Taiwan 886 (2) 2722-9622

United Kingdom & Ireland +44 (0) 1344 392400

USA 1 (800) 426-2200

For other areas contact Tektronix, Inc at: 1 (503) 627-7111

Updated 5 August 2009

For Further Information. Tektronix maintains a comprehensive, constantly expandingcollection of application notes, technical briefs and other resources to help engineers workingon the cutting edge of technology. Please visit www.tektronix.com

Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,issued and pending. Information in this publication supersedes that in all previously published material.Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks ofTektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarksof their respective companies.

15 Oct 2009 3MW-23595-1

www.tektronix.com/dmm