Tempcon Instrumentation Ltd. Unit 19, Ford Lane Business Park, Ford Lane Ford, Nr. Arundel, West Sussex. BN18 0UZ Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288 Email: [email protected] Web site: www.tempcon.co.uk Digitron VAP Series of Panel Indicators B324 Digitron’s VAP Series offer a range of high accuracy performance panel meters designed for use with pressure transducers, high voltage transducers and current loop sensors. Features include: Highly accurate performance Large LED display Easy to use Controller model Superb value Compact design All models incorporate a decimal point position selection and continuous scaling of gain, from full scale > 250 to < 1999, using jumper links, zero and gain adjustment control The VAP Series are supplied with a set of standard engineering units for customer use. The appropriate symbol should be fixed to the front panel. A440 SERIES CURRENT LOOP INDICATORS Digitron’s A440 Series current loop indicators are designed for use with any current loop sensor, which gives out a dc current in the range 0-20mA, or 4- 20mA. 0mA or 4mA ‘zero’ inputs are selectable, with further offset adjustment for sensor calibration (using jumper links). Both instruments give out a nominal excitation voltage of 24V dc and can also be used as repeaters on loops, which are already powered. Two models are available: The model A445 indicator and the model A448 indicator with single set point.

Digitron VAP

Embed Size (px)

DESCRIPTION

degitron

Citation preview

Page 1: Digitron VAP

Tempcon Instrumentation Ltd. Unit 19, Ford Lane Business Park, Ford Lane Ford, Nr. Arundel, West Sussex. BN18 0UZ Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

Email: [email protected] Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators

B324

Digitron’s VAP Series offer a range of high accuracy performance panel meters designed for use with pressure transducers, high voltage transducers and current loop sensors.

Features include:

Highly accurate performance

Large LED display

Easy to use

Controller model

Superb value

Compact design

All models incorporate a decimal point position selection and continuous scaling of gain, from full scale > 250 to < 1999, using jumper links, zero and gain adjustment control

The VAP Series are supplied with a set of standard engineering units for customer use. The appropriate symbol should be fixed to the front panel.

A440 SERIES CURRENT LOOP INDICATORS

Digitron’s A440 Series current loop indicators are designed for use with any current loop sensor, which gives out a dc current in the range 0-20mA, or 4-20mA.

0mA or 4mA ‘zero’ inputs are selectable, with further offset adjustment for sensor calibration (using jumper links). Both instruments give out a nominal excitation voltage of 24V dc and can also be used as repeaters on loops, which are already powered.

Two models are available:

The model A445 indicator and the model A448 indicator with single set point.

Page 2: Digitron VAP

Tempcon Instrumentation Ltd. Unit 19, Ford Lane Business Park, Ford Lane Ford, Nr. Arundel, West Sussex. BN18 0UZ Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

Email: [email protected] Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators

B324

P440 SERIES PRESSURE INDICATORS

Digitron’s P440 Series pressure indicators are designed for use with pressure transducers with a full-scale output 100mV or other strain gauge device.

Two models are available:

Model P445 indicator and model P448 indicator with single set point.

The instruments give a 10V dc excitation voltage and can be adjusted to give full-scale indication for other than 100mV using jumper links, zero and gain adjustment control.

V440 SERIES BRIDGE TRANSDUCER INDICATOR

The V440 series transducer Indicators are designed for use with any 3 terminal transducer which requires a nominal + 24V dc excitation voltage and gives out a signal in the range 0-5V or 0-10V dc (1-6V, 1-11V dc with offset).

Two models are available:

Model V445 indicator, and model V448 indicator with single set point each with 2 ranges, 0-5V (1-6Vdc with offset). or 0-10V (1-11V dc with offset). Both instruments give out a nominal excitation voltage of 24V dc.

Reliability

All models are subjected to detailed inspection and a rigorous testing programme before being calibrated. All models are also supplied with a 12 month warranty on parts and labour

Page 3: Digitron VAP

Tempcon Instrumentation Ltd. Unit 19, Ford Lane Business Park, Ford Lane Ford, Nr. Arundel, West Sussex. BN18 0UZ Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

Email: [email protected] Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators

B324

Applications

Application A440 P440 V440

Air X Amps/Volts/Power X X

Compressors X Displacement X X

Engines X Flow X X

Frequency X X

Gas X

Heating & Ventilating X

Industrial Hydraulics X Oil X pH X X

Pressure X X

Refrigeration X Speed X X

Strain X X

Temperature X X

Water X

Page 4: Digitron VAP

Tempcon Instrumentation Ltd. Unit 19, Ford Lane Business Park, Ford Lane Ford, Nr. Arundel, West Sussex. BN18 0UZ Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

Email: [email protected] Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators

B324

Specification

A440 P440 V440

Input 0-20mA full scale or 4-20mA full scale selectable

with jumper link

100mV full scale output 0-5, 1-6V dc pre-set by manufacturer or 0-10, 1-11V

dc (please specify)

Transducer/Excitation Voltage

24V dc nominal 10Vdc 24dc nominal

Display 31/2 digit, 13.5mm LED 31/2 digit, 13.5mm LED 31/2 digit, 13.5mm LED

Range-Full Scale Adjustable from. 250 to 1999 Counts

Adjustable from. 250 to 1999 Counts

Adjustable from. 250 to 1999 Counts

Decimal Point Position Selectable using jumper link Selectable using jumper link Selectable using jumper link

Indicator Accuracy Linearity ±1 digit Stability typically 100ppm/°C

0.2% of reading ±1 count Linearity ±1 digit Stability typically 100ppm/°C

Power Supply 230/115V ac ±15% (selectable), 50/60 Hz

230/115V ac ±15% (selectable) 50/60 Hz

230/115V ac ±15% (selectable), 50/60 Hz

Zero Offset Control Adjustable pots and jumper links access from behind

front panel

Adjustable pots and jumper links access from behind

front panel

Adjustable pots and jumper links access from behind front panel

Operational Temperature Range

0-40°C 0-40°C 0-40°C

Dimensions Cut Out

96x48x68.1mm (after DIN 43700) 92x45mm + 1.0mm –

0.0mm

96x48x68.1mm (after DIN 43700) 92x45mm + 1.0mm-

0.0mm

96 x 48 x 68.1mm (After DIN 43700) 92 x 45mm + 1.0mm –0.0mm

Changeover Relay Heavy duty silver Cadmium Oxide 5 amps resistive load

@240V ac

Heavy duty Silver Cadmium Oxide 5 amps resistive load

@240V ac

Heavy duty Silver Cadmium Oxide 5 amps resistive load @ 240V ac

Setpoint Hysteresis Adjustable pot (±1 count up to ±10 counts), access through vents on right

(Model A448 only)

Adjustable pot (±1 count up to ±10 counts) access through

vents on right hand side of case.

(Model P448 only)

Adjustable pot (± 1 count up to ±10 counts) access through vents

on right hand side of case. (Model V448 only)