2
LED Approach Flash Lighting System Dimensions URL: http:www.nelt.co.jp/ TEL : +81-(0)3-6746-1770 E-mail : [email protected] Lighting Unit : FX-AVC-01 FX-AVC-01 LED flashing supports safe landing of aircrafts Lighting quality equivalent to Xenon (Dimmable) 20 years Maintenance free design Significant Energy Saving Controller Unit : FX-C-3 Power Unit : FX-AVC-02 Ø62 Ø70 149 228 3-M8 413 287 Ø286 53 261 45 Lighting Unit FX-AVC-02 Power Unit FX-C-3 Controller Unit Front Front Front Top Back Side Side Side 300 3496 600 800 600 100 700 650 50 530 328 413 20

Dimensions LED Approach Flash Lighting SystemNEC Approach Flash Lighting System Remarks Descriptions Lighting Unit Power Unit Controller Unit Dimensions (mm) 287 x 228 x 413 530 x

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Dimensions LED Approach Flash Lighting SystemNEC Approach Flash Lighting System Remarks Descriptions Lighting Unit Power Unit Controller Unit Dimensions (mm) 287 x 228 x 413 530 x

LED Approach Flash Lighting SystemDimensions

URL: http:www.nelt.co.jp/

TEL : +81-(0)3-6746-1770E-mail : [email protected]

Lighting Unit : FX-AVC-01

FX-AVC-01

LED flashing supports safe landing of aircraftsLighting quality equivalent

to Xenon (Dimmable)20 years

Maintenance free designSignificant Energy Saving

Controller Unit : FX-C-3

Power Unit : FX-AVC-02

Ø62

Ø70

149

228

3-M8

413

287

Ø286

53

261

45

■ Lighting Unit

FX-AVC-02■ Power Unit

FX-C-3■ Controller Unit

Front

Front

Front

Top

Back Side

Side

Side

300

(349)

6600

800

600

100

700650

50530 328

413

20

Page 2: Dimensions LED Approach Flash Lighting SystemNEC Approach Flash Lighting System Remarks Descriptions Lighting Unit Power Unit Controller Unit Dimensions (mm) 287 x 228 x 413 530 x

2A,2ms

2ms

Constant current plus emitting

Xenon 500VA Xenon Lump 500H

LED 107VA LED Module 40,000H

20 years maintenance free

■ Energy Saving (Power Consumption) ■ Less Maintenance (Life Time)

Heater ElectrodesHeater Electrodes

■ Front panel heating test data

■Center of Front Panel ………………………… 25±5K■Maximum Temp ………………………………… 40K■Time to reach 80% of Maximum Temp …… 7 minutes

Benefits Approach Flash Lighting System Applications

Brief Technical DataNEC Approach Flash Lighting System Remarks

Descriptions Lighting Unit Power Unit Controller UnitDimensions (mm) 287 x 228 x 413 530 x 328 x 413 600 x 300 x 800Weight (kg) 5.6 30 58.6Timing Signal Voltage AC100V・pulse 30mS to 40mSMonitor Signal 1KΩ Normal Condition = ∞Flash Frequency 120/minutesLight Output High 6,000cd - 20,000cd +10%

Middle 600cd - 2,000cd +10%Low 100cd - 450cd +10%

Power Consumption Heater Off High: 70.0W Middle: 22.0W Low: 18.0WHigh: 107.0VA Middle: 31.0VA Low: 24.0VA

Heater On High: 87.0W Middle: 38.0W Low: 34.0WHigh: 127.0VA Middle: 56.0VA Low: 50.0VA

Heater Power Consumption 10WAdjustable Vertical Angle 0°to 30°Operating Temperature -40℃ to 55℃IP Rating IP66Material Aluminum and Stainless SteelCompliances ICAO Annex 14 vol. 1

JCAB Lighting Spec # 356FAA L-849E/EB-67D ( Apprication process underway)

Center value of Beam

Frigid Environment Field Test @ Shin-Chitose Airport in Hokkaido

① SFL (Sequenced Flashing Lights)

③ AGL (Approach Guidance Lights)

④ RAI (Runway Alignment Indicators)

② REIL (Runway End Identifier Lights)  RWYTIL (Runway Threshold Identification Lights)

Ingress Protection Field Test @Naha Airport in Okinawa

High output Flip-chip LEDLED Module

700lm×1,184 pieces≒830,000 lumens

High density mounting

2A

2.1mm□LED

Achieved Lighting Quality equivalent to that of conventional Xenon lump

Significant Enaergy Saving and 20 years maintenance free design

Safety operation by Laminated Heater (Optional)

LED module decreases 80% of power consumption and increases significant life time compared withXenon lump*

Secure safety operation in a frigid environment

Other Key Features・Lighting-up time adjustment function for the reduction of the load on boot-up.・Luminance back-up function in case of LED circuit failures by the adjustments of flashing time. (* Middle and Low mode only. Up to 7/16(total) LED circuit failures.)・Self diagnosis function for each Lighting Unit.

Prevents the front panel from freezingby the laminated heating technology

*Conditions:Operating hour=5H/day, No heater operation, Life time:Xenon=500H. LED=40,000H

(Flashing simultaneous right and left once per 0.5sec)