51 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Individual mounting Series
D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s
SERIES FEATURES
36
32
3738
3334
5267
46
44
47
42
400
48
92
93
ISO 1ISO 2 ISO 3
69
48P
ISO 01ISO 02
Sub-base non “plug-in”
Sub-base“plug-in”
Sub-base/manifold basenon “plug-in” with latching
solenoid
Sub-base/manifold base
“plug-in” with latching
solenoid
Series 38
• High force MACSOLENOID®.• Integral 4-way pilot design.• Internal or external pilot.• Normally open or normally closed function.• Universal function (external pilot).• Rectified AC voltage.• Latching solenoid technology.
1 2 3
Solenoid
Manual operator
Integral 4-way pilot
Air returnBonded spool
Manifold base“plug-in”
Sub-base/manifold basenon “plug-in” with latching
solenoid
Sub-base/manifold base
“plug-in” with latching
solenoid
Manifold mounting
Function Port size Flow (Max) Individual mounting Series
OPERATIONAL BENEFITS
D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s
H O W T O O R D E R
53 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
3738
3334
5267
46
44
47
42
400
48
92
93
ISO 1ISO 2 ISO 3
69
48P
ISO 01ISO 02
Series 38
3/2 NO-NC 1/8” 1.2 Cv Sub-basenon “plug-in”
1. 3-way valve with 4-way integral pilot.2. 10 mm valve (stacks on 16.5 mm centers).3. High flow (up to 1.2 Cv).4. Fast, repeatable response times.5. Maximum shifting forces in both directions.
38B-XMX-XAX-GXXX-XXX
O P T I O N S
A Individual base – Side portB Individual base – Bottom port
M Pilot exhaust muffledP Pilot exhaust piped (# 10-32)U Pilot exhaust to main exhaust
NO valve
38B-BMA-000-GXXX-XXX
38B-BMB-000-GXXX-XXX
38B-BMA-AAL-GXXX-XXX
38B-BMB-AAM-GXXX-XXX
NC valve
38B-AMA-000-GXXX-XXX
38B-AMB-000-GXXX-XXX
38B-AMA-AAL-GXXX-XXX
38B-AMB-AAM-GXXX-XXX
Universal valve
38B-GMB-000-GXXX-XXX
38B-GMB-AAM-GXXX-XXX
Port size
Valve less base
1/8” NPTF
Pilot air
Internal
External
Internal
External
Note : Above codes are for side port.
G XXX-XXX *STANDARD SOLENOID OPERATOR �
Pilot/Base Configuration :
Voltage
AA 120 VAC (2.5W)DA 24 VDC (1.0W)DC 24 VDC (1.8W)DD 24 VDC (2.5W)DF 24 VDC (4.0W)
Wire length
A 18”B 24”C 36”
Manual operator
1 Non-locking recessed2 Locking recessed
Electrical connection
BA Flying leadsBT Flying leads with lightGA MAC JAC Solenoid plug-inGB MAC JAC Solenoid plug-in
w/DiodeGC MAC JAC Solenoid plug-in
w/MOVGD MAC JAC Solenoid plug-in
w/LEDGE MAC JAC Solenoid plug-in
w/Diode & LEDGF MAC JAC Solenoid plug-in
w/MOV & LEDGG MAC JAC Solenoid plug-in
w/RectifierGH MAC JAC Solenoid plug-in
w/Rectifier & LEDKA Plug-in wire assemblyKT Plug-in wire assembly with
lightKD Plug-in wire assembly with
rectifier & light & ground
XX X X XX
Note : AC voltage requires connector with rectifier.* Other options available, see page 311.Latching solenoid also available, see page 59.With MAC JAC electrical connector washdown capability is possible.Consult factory for modification number.
2 1210
13
21210
13
21210
13
23.3
8.0
116.9
97.6
Ø 5.3
19.0
31.5
44.3
28.4
4.3
46.4
83.0
9.7
4.34.8
16.6
12.0
86.0
MO
DEL
AU
CKLA
ND
, N.Z.
LIEGE, BELG
IUM
WIXO
M, M
I. USA
MO
DIF.
VAC
TO 150 PSI
31
EP
P
2
10
1818100%100%
100%100% M O N T H S
WARRANTY
O FP R O D U C T I O N
T E S T E D
D I M E N S I O N S
T E C H N I C A L D A T A
Dimensions shown are metric (mm)
54 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series 38
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv)
Class A wire (#22 AWG x 18), continuous duty
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :
Function Port size Flow (Max) Individual mounting Series
OPERATIONAL BENEFITS
D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s
H O W T O O R D E R
55 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
3738
3334
5267
46
44
47
42
400
48
92
93
ISO 1ISO 2 ISO 3
69
48P
ISO 01ISO 02
Series 38
3/2 NO-NC 1/8” - 1.2 Cv1/4” O.D. tube receptacle
Sub-base“plug-in”
1. 3-way valve with 4-way integral pilot.2. 10 mm valve (stacks on 16.5 mm centers).3. High flow (up to 1.2 Cv).4. Fast, repeatable response times.5. Maximum shifting forces in both directions.
38B-XMX-XAX-GXX P-XXX
O P T I O N S
A Individual base – Side portB Individual base – Bottom port
M Pilot exhaust muffledP Pilot exhaust piped (# 10-32)U Pilot exhaust to main exhaust
NO valve
38B-BMA-000-GXXP-XXX
38B-BMB-000-GXXP-XXX
38B-BMA-AAA-GXXP-XXX
38B-BMB-AAB-GXXP-XXX
38B-BMA-EAA-GXXP-XXX
38B-BMB-EAB-GXXP-XXX
NC valve
38B-AMA-000-GXXP-XXX
38B-AMB-000-GXXP-XXX
38B-AMA-AAA-GXXP-XXX
38B-AMB-AAB-GXXP-XXX
38B-AMA-EAA-GXXP-XXX
38B-AMB-EAB-GXXP-XXX
Universal valve
38B-GMB-000-GXXP-XXX
38B-GMB-BAB-GXXP-XXX
38B-GMB-EAB-GXXP-XXX
Port size
Valve less base
1/8” NPTF
1/4” O.D.
Tube receptacle
Pilot air
Internal
External
Internal
External
Internal
External
Note : Above codes are for side port.
Voltage
AA 120 VAC (2.5W)DA 24 VDC (1.0W)DC 24 VDC (1.8W)DD 24 VDC (2.5W)DF 24 VDC (4.0W)
Manual operator
1 Non-locking recessed2 Locking recessed
Electrical connection
SA Base plug-inSJ Base plug-in with lightSS Base plug-in with rectifier & light & ground
G XX P-XXX *STANDARD SOLENOID OPERATOR �
XX X XX
Note : AC voltage requires connector with rectifier.* Other options available, see page 311.Latching solenoid also available, see page 61.
Pilot/Base Configuration :
2 1210
13
21210
13
21210
13
Washdown capability is possible, consult factory for modification number.
131.0
9.7
4.0
115.8
6.4
50.4
VAC
TO 150 PSI
MO
DIF.
AU
CKLA
ND
, N.Z.
LIEGE, BELG
IUM
WIXO
M, M
I. USA
MO
DEL
23.3
8.0
2
76.0
31.5
1818100%100%
100%100% M O N T H S
WARRANTY
O FP R O D U C T I O N
T E S T E D
D I M E N S I O N S
T E C H N I C A L D A T A
Dimensions shown are metric (mm)
56 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series 38
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :
Function Port size Flow (Max) Manifold mounting Series
OPERATIONAL BENEFITS
D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s
H O W T O O R D E R
57 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
3738
3334
5267
46
44
47
42
400
48
92
93
ISO 1ISO 2 ISO 3
69
48P
ISO 01ISO 02
Series 38
3/2 NO-NC 1/8” - 1.2 Cv1/4” O.D. tube receptacle
Manifold base“plug-in”
1. 3-way valve with 4-way integral pilot.2. 10 mm valve (stacks on 16.5 mm centers).3. High flow (up to 1.2 Cv).4. Fast, repeatable response times.5. Maximum shifting forces in both directions.
38B-XXX-XJX-GXX P-XXX
O P T I O N S
J Manifold base – Side portK Manifold base – Bottom portL Left end manifold base – Side portM Left end manifold base – Bottom portN Right end manifold base – Side portP Right end manifold base – Bottom port
Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold and middle station manifolds (options "J" or "K").
NO valve
38B-BMA-000-GXXP-XXX
38B-BMB-000-GXXP-XXX
38B-BMA-AJA-GXXP-XXX
38B-BMB-AJB-GXXP-XXX
38B-BMA-EJA-GXXP-XXX
38B-BMB-EJB-GXXP-XXX
NC valve
38B-AMA-000-GXXP-XXX
38B-AMB-000-GXXP-XXX
38B-AMA-AJA-GXXP-XXX
38B-AMB-AJB-GXXP-XXX
38B-AMA-EJA-GXXP-XXX
38B-AMB-EJB-GXXP-XXX
Universal valve
38B-GMB-000-GXXP-XXX
38B-GMB-BJB-GXXP-XXX
38B-GMB-EJB-GXXP-XXX
Port size
Valve less base
1/8” NPTF
1/4” O.D.
Tube receptacle
Pilot air
Internal
External
Internal
External
Internal
External
Note : Above codes are for side port.
Voltage
AA 120 VAC (2.5W)DA 24 VDC (1.0W)DC 24 VDC (1.8W)DD 24 VDC (2.5W)DF 24 VDC (4.0W)
Manual operator
1 Non-locking recessed2 Locking recessed
Electrical connection
SA Base plug-inSJ Base plug-in with lightSS Base plug-in with rectifier & light & ground
G XX P-XXX *STANDARD SOLENOID OPERATOR �
XX X XX
Note : AC voltage requires connector with rectifier.* Other options available, see page 311.Latching solenoid also available, see page 61.Washdown capability is possible, consult factory for modification number.
Base Configuration :
38B-000-XXX(i.e. 38B-000-AJA)
Base only :
2 1210
13
21210
13
21210
13
1818100%100%
100%100% M O N T H S
WARRANTY
O FP R O D U C T I O N
T E S T E D
D I M E N S I O N S
T E C H N I C A L D A T A
Dimensions shown are metric (mm)
58 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series 38
CONDUIT3/4"-14
51.5
16.523.3
2222
47.5
55.5
33.529.5
12.016.7
107.1
82.372.7
28.4
TYP.
TYP.
TYP.4.0
9.7
TYP.TYP.
TYP.23.3
16.531.5
8.0
VA
C T
O 150 P
SI
MO
DIF
.
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DE
L
2
Ø 5.3TYP.
1/4" O.D. TUBE FITTING1/8" TAPPED OR
3/8" IN & EXH
EXT. PILOT1/8" COMMON
1/4" O.D. TUBE FITTING1/8" TAPPED OR
131.0115.8
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
VA
C T
O 150 P
SI
MO
DIF
.
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DE
L
2
1
3
EP
CO
ND
22
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
76.0
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :
OPERATIONAL BENEFITS
D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s
H O W T O O R D E R
59 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
3738
3334
5267
46
44
47
42
400
48
92
93
ISO 1ISO 2 ISO 3
69
48P
ISO 01ISO 02
Series 38
Function Port size Flow (Max) Individual/Manifold mounting Series
3/2 NO-NC 1/8” - 1.2 Cv1/4” O.D. tube receptacle
Sub-base/manifold basenon “plug-in” with latching
solenoid
1. 3-way valve with 4-way integral pilot.2. 10 mm valve (stacks on 16.5 mm centers).3. High flow (up to 1.2 Cv).4. Fast, repeatable response times.5. Maximum shifting forces in both directions.
38A-XMX-XAX-LXXX-XXX
O P T I O N S
A Individual base – Side portB Individual base – Bottom portJ Manifold base – Side portK Manifoldl base – Bottom port
M Pilot exhaust muffledP Pilot exhaust piped (#10-32)U Pilot exhaust to main exhaust
Note : Above codes are for individual base and side port.
L XXX-XXX *LATCHING SOLENOID OPERATOR �
* Other options available, see page 319.** Latching 38 series with non plug-in base configuration must use "B", "K" or "L" type electrical connector.
Note : Manifold assemblies require an end plate kit : M-38003-01-01 (internal pilot)M-38003-02-01 (external pilot)
Pilot/Base Configuration :
Voltage
DF 24 VDC (4.0W)HA 24 VDC (1.95W)
Wire length
A 18”B 24”C 36”
Manual operator
0 No operator
Electrical connection**
BA 2 Wire Flying leadsBJ 4 Wire Flying leads KA 2 Wire Plug-in AssemblyKE 4 Wire Plug-in AssemblyLA 3 Wire plug-in assembly
(Polarity Switching Cover)
XX X X XX
NO valve
38A-BMA-000-LXXX-XXX
38A-BMB-000-LXXX-XXX
38A-BMA-AAL-LXXX-XXX
38A-BMB-AAM-LXXX-XXX
38A-BMA-EAL-LXXX-XXX
38A-BMB-EAM-LXXX-XXX
NC valve
38A-AMA-000-LXXX-XXX
38A-AMB-000-LXXX-XXX
38A-AMA-AAL-LXXX-XXX
38A-AMB-AAM-LXXX-XXX
38A-AMA-EAL-LXXX-XXX
38A-AMB-EAM-LXXX-XXX
Universal valve
38A-GMB-000-LXXX-XXX
38A-GMB-AAM-LXXX-XXX
38A-GMB-EAM-LXXX-XXX
Port size
Valve less base
1/8” NPTF
1/4” O.D.
Tube receptacle
Pilot air
Internal
External
Internal
External
Internal
External
21210
13
21210
13
2 12
13
10
1818100%100%
100%100% M O N T H S
WARRANTY
O FP R O D U C T I O N
T E S T E D
D I M E N S I O N S
T E C H N I C A L D A T A
60 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series 38
VAC
TO 150 PSI
MO
DIF.
AU
CKLA
ND
, N.Z.
LIEGE, BELG
IUM
WIXO
M, M
I. USA
MO
DEL
86.0
12.0
16.6
4.8 4.3
9.7
83.0
46.4
4.3
28.4
44.3
31.519.0
Ø 5.3
97.6
8.0
23.3
125.5
10
2
PEP
13
125.5
51.4
27.3
19.027.3
46.3
4.34.3
EP
1
3
P
TYP.Ø 5.3
16.5
82.3
72.7
28.4
47.5
47.529.5
16.7
12.0
TYP.TYP.
TYP.
TYP. TYP.
TYP.
16.5
8.0
76.0
2222
VA
C T
O 150 P
SI
MO
DIF
.
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DE
L
2
1/4" O.D. TUBE FITTING1/8" TAPPED OR
3/8" IN & EXH
EXT. PILOT1/8" COMMON
1/4" O.D. TUBE FITTING1/8" TAPPED OR
22 2
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv)
Class A wires (#22 AWG x 18), continuous duty
-15% to +10% of nominal voltage
1.95 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :
Individual base Manifold base
OPERATIONAL BENEFITS
D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s
H O W T O O R D E R
61 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
3738
3334
5267
46
44
47
42
400
48
92
93
ISO 1ISO 2 ISO 3
69
48P
ISO 01ISO 02
Series 38
Function Port size Flow (Max) Individual/Manifold mounting Series
3/2 NO-NC 1/8” - 1.2 Cv1/4” O.D. tube receptacle
Sub-base/manifold base
“plug-in” with latching
solenoid
1. 3-way valve with 4-way integral pilot.2. 10 mm valve (stacks on 16.5 mm centers).3. High flow (up to 1.2 Cv).4. Fast, repeatable response times.5. Maximum shifting forces in both directions.
Voltage
DF 24 VDC (4.0W)HA 24 VDC (1.95W)
Manual operator
0 No operator
Electrical connection**
DA Base/Manifold Plug-inDB Base/Manifold Plug-in w/GroundDC Base/Manifold Plug-in w/ LedDD Base/Manifold Plug-in w/ Led and GroundEA Base/Manifold Plug-in 3 Pin
(Polarity Switching Cover)
L XX P-XXX *LATCHING SOLENOID OPERATOR �
XX X XX
38A-XXX-XAX-LXXP-XXX
O P T I O N S
A Individual base – Side portB Individual base – Bottom portJ Manifold base – Side portK Manifold base – Bottom portL Left end manifold base – Side portM Left end manifold base – Bottom portN Right end manifold base – Side portP Right end manifold base – Bottom port
* Other options available, see page 319.** 2 and 4 wire bases must use "D" type electrical connector.
3 wire base must use "EA" type electrical connector.
Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (option J or K).
Manifold/Base Configuration :
38A-XXX-XXA-LXXP-XXX
A Plug-In Int. Pilot (2 Wire)**B Plug-In Ext. Pilot (2 Wire)**C Plug-In Int. Pilot (3 Wire)**D Plug-In Ext. Pilot (3 Wire)**E Plug-In Int. Pilot (4 Wire)**F Plug-In Ext. Pilot (4 Wire)**
Manifold/Base Int./Ext. Pilot : (Wire options)
Note : Above codes are for individual base and side port.
NO valve
38A-BMA-000-LXXP-XXX
38A-BMB-000-LXXP-XXX
38A-BMA-AAA-LXXP-XXX
38A-BMB-AAB-LXXP-XXX
38A-BMA-EAA-LXXP-XXX
38A-BMB-EAB-LXXP-XXX
NC valve
38A-AMA-000-LXXP-XXX
38A-AMB-000-LXXP-XXX
38A-AMA-AAA-LXXP-XXX
38A-AMB-AAB-LXXP-XXX
38A-AMA-EAA-LXXP-XXX
38A-AMB-EAB-LXXP-XXX
Universal valve
38A-GMB-000-LXXP-XXX
38A-GMB-AAB-LXXP-XXX
38A-GMB-EAB-LXXP-XXX
Port size
Valve less base
1/8” NPTF
1/4” O.D.
Tube receptacle
Pilot air
Internal
External
Internal
External
Internal
External
21210
13
21210
13
2 12
13
10
1818100%100%
100%100% M O N T H S
WARRANTY
O FP R O D U C T I O N
T E S T E D
D I M E N S I O N S
T E C H N I C A L D A T A
Dimensions shown are metric (mm)
62 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series 38
50.4
6.4
115.8
4.0
9.7
131.0
MO
DEL
AU
CKLA
ND
, N.Z.
LIEGE, BELG
IUM
WIXO
M, M
I. USA
MO
DIF.
VAC
TO 150 PSI
8.0
23.3
2
31.5
76.0
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
1.95 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :
CONDUIT3/4"-14
51.5
16.523.3
2222
47.5
55.5
33.529.5
12.016.7
107.1
82.372.7
28.4
Ø 5.3TYP.
1/4" O.D. TUBE FITTING1/8" TAPPED OR
3/8" IN & EXH
EXT. PILOT1/8" COMMON
1
3
EP
CO
ND
TYP.
TYP.
TYP.4.0
9.7
VA
C T
O 150 P
SI
MO
DIF
.
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DE
L
131.0115.8
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
VA
C T
O 150 P
SI
MO
DIF
.
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DE
L
MO
DE
L
AU
CK
LAN
D, N
.Z.
LIEG
E, B
ELG
IUM
WIX
OM
, MI. U
SA
MO
DIF
.V
AC
TO
150 PS
I
TYP.TYP.
TYP.23.3
16.531.5
8.0
2
1/4" O.D. TUBE FITTING1/8" TAPPED OR
222
76.0
Individual base Manifold base
311 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
O P T I O N S
Codification table for voltages / Manual operator / Electrical connection
- Solenoid valves 32, 34, 38, 42, 44 & 48 Series
G XX X-X XX1 2 3 4
VALVE CODE �
OPTIONS AVAILABLE FOR
312 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
O P T I O N S
1. VOLTAGE
G-XX X-X XX VOLTAGEAA 120 VAC (2.5W) Requires electrical connector with rectifierAC 24 VAC (4.0W) Requires electrical connector with rectifierDA 24 VDC (1.0W)DC 24 VDC (1.8W)DD 24 VDC (2.5W)DE 24 VDC (3.0W)DF 24 VDC (4.0W)DG 12 VDC (1.0W)DJ 12 VDC (1.8W)DK 12 VDC (2.5W)DM 12 VDC (3.0W)DN 12 VDC (4.0W)DR 6 VDC (1.8W)DS 6 VDC (3.0W)EB 48 VDC (1.8W)EC 48 VDC (3.0W)ED 120 VDC (2.5W)GD 12 VDC (0.5W) 34 series onlyGE 24 VDC (0.5W) 34 series only
2. WIRE LENGTH
G-XX X-X XX WIRE LENGTH0 No lead wires (used only with "KJ" & "KM" connectors)A 18" coil leadsB 24" coil leadsC 36" coil leadsD 48" coil leadsE 72" coil leadsF 96" coil leadsG 120" coil leadsH 144" coil leads1 18" base leads2 24" base leads3 36" base leads4 48" base leads5 72" base leads6 96" base leads7 120" base leads
3. MANUAL OPERATOR
G-XX X-X XX MANUAL OPERATOR1 Non-locking recessed2 Locking recessed3 Non-locking extended4 Locking extended
4. ELECTRICAL CONNECTION
G-XX X-X XX ELECTRICAL CONNECTIONBA Flying leadsBB BA with ground wireBC BA with lightBD BA with light and ground wireBE BA with suppression diodeBF BA with suppression diode and ground wireBG BA with suppression diode and lightBH BA with suppression diode, light and ground wireBN BA with suppression diode and blocking diodeBP BA with suppression diode, blocking diode and ground wireBR BA with suppresion diode, blocking diode and lightBS BA with suppression diode, blocking diode, light and ground
wireGA MAC JAC Solenoid plug-inGB MAC JAC Solenoid plug-in w/DiodeGC MAC JAC Solenoid plug-in w/MOV GD MAC JAC Solenoid plug-in w/LEDGE MAC JAC Solenoid plug-in w/Diode & LEDGF MAC JAC Solenoid plug-in w/MOV & LEDGG MAC JAC Solenoid plug-in w/RectifierGH MAC JAC Solenoid plug-in w/Rectifier & LEDKA Solenoid plug-in wire assemblyKB KA with groundKC KA with rectifier and lightKD KA with rectifier, light and groundKE KA with suppression diodeKF KA with suppression diode and groundKJ Solenoid plug-in housing without wire assemblyKM Solenoid plug-in housing with ground pin without wire
assemblyKN KA with suppression diode and blocking diodeKP KA with suppression diode, blocking diode and groundKT KA with lightKU KA with light and groundKV KA with suppression diode and light KW KA with suppression diode, light and groundKX KA with suppression diode, blocking diode and lightKY KA with suppression diode, blocking diode, light & ground
ELECTRICAL CONNECTION FOR PLUG-IN VALVES
G-XX X-X XX PLUG-IN OPTIONSSB Base plug-in with groundSC Base plug-in with suppression and blocking diodeSD Base plug-in with suppression and blocking diode and groundSE Base plug-in with MOVSF Base plug-in with MOV and groundSG Base plug-in with rectifierSH Base plug-in with rectifier and groundSK Base plug-in with light and groundSL Base plug-in with suppression and blocking diode and lightSM Base plug-in with suppression and blocking diode with light
and groundSN Base plug-in with MOV and lightSP Base plug-in with MOV and light with groundSR Base plug-in with rectifier and light
319 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
O P T I O N S
Codification table for voltages / Manual operators / Electrical connections
- Solenoid valves 32, 38, 42, 44, 47 & 48 Series
OPTIONS AVAILABLE FOR
L XX X-X XX1 2 3 4
VALVE CODE �
320 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
2. WIRE LENGTH (all series)
L- XX X-X XX WIRE LENGTH
0 No lead wire
A 18"
B 24"
C 36"
D 48"
E 72"
F 96"
G 120"
H 144"
3. MANUAL OPERATOR (all series)
L- XX X-X XX MANUAL OPERATOR
0 No operator
O P T I O N S
1. VOLTAGE (32, 38, 42, 44, 48 SERIES)
L- XX X-X XX VOLTAGE
DF 24VDC (4.0W)
DN 12VDC (4.0W)
HA 24VDC (1.95W)
HE 12VDC (1.95W)
1. VOLTAGE (47 SERIES)
L- XX X-X XX VOLTAGE
DA 24VDC (5.2W)
DF 12VDC (5.2W)
4. ELECTRICAL CONNECTOR (32, 38, 42, 44 & 48 series)
L-XX X-X XX NON PLUG-INBA 2 wire flying leadsBB 2 wire flying leads with ground wireBC 2 wire flying leads with lightBD 2 wire flying leads with light & ground wireBJ 4 wire flying leadsBK 4 wire flying leads with groundBL 4 wire flying leads with lightBM 4 wire flying leads with light & ground wireKA 2 wire plug-in assemblyKB 2 wire plug-in assembly with ground wireKC 2 wire plug-in assembly with lightKD 2 wire plug-in assembly with light and ground wireKE 4 wire plug-in assemblyKF 4 wire plug-in assembly with ground wireKG 4 wire plug-in assembly with lightKH 4 wire plug-in assembly and ground wireLA 3 wire plug-in assembly (polarity switching cover)
L-XX X-X XX PLUG-IN*DA Base plug-in*DB Base plug-in with ground pin*DC Base plug-in with light*DD Base plug-in with light & ground pin
**EA Base plug-in 3 pin (Plarity switching cover)* Use these options for plug-in base with 2 or 4 wire assemblies** Use this option for plug-in bases with 3 wire assemblies
4. ELECTRICAL CONNECTOR (47 series)
L- XX X-X XX NON PLUG-INBA 2 wire flying leadsBB 2 wire flying leads with ground wireBC 2 wire flying leads with lightBD 2 wire flying leads with light & ground wireBJ 4 wire flying leadsBK 4 wire flying leads with groundBL 4 wire flying leads with lightBM 4 wire flying leads with light & ground wireLA 3 wire plug-in assembly (Plarity switching cover)MA 2 wire plug-in assemblyMB 2 wire plug-in assembly with ground wireMC 2 wire plug-in assembly with lightMD 2 wire plug-in assembly with light and ground wireME 4 wire plug-in assemblyMF 4 wire plug-in assembly with ground wireMG 4 wire plug-in assembly with lightMH 4 wire plug-in assembly with light and ground wire
L- XX X-X XX PLUG-INEA Base plug-in 3 pin (Polarity switching cover)FA Base plug-in with groundFB Base plug-in with ground & lightFC Base plug-in 4 wire with groundFD Base plug-in 4 wire with light & ground