Thermo Scientific Charged Aerosol Detectors
Discover what you’re missing
The analyte detection challengeNo single liquid chromatography (LC) detector delivers ideal results. Often, one analyte responds more strongly than another, or may not respond at all. What is most desired is the ability to detect a wide range of analytes (universal detection) with a response that enables accurate quantitation. Charged aerosol detection is a reliable technology that will change the way you view every sample. The Charged Aerosol Detector (CAD) can detect all non-volatile, and many semi-volatile analytes, with uniform response.
With the flexibility and performance for analytical R&D, and the simplicity and reproducibility needed for manufacturing QA/QC, charged aerosol detection can be used for the analysis of pharmaceuticals (large and small molecule), biomolecules, foods and beverages, specialty chemicals, and polymers.
2
Unlike mass spectrometry (A) and UV (B), the CAD is able to measure all analytes in the sample. Mass spectrometry (MS) requires the analyte to form gas phase ions while response by a UV detector depends upon the nature of the chromophore.
0 2 4Time [min] Time [min]
MS TIC positive ion scanm/z 250−1250
Erucamide Stearic acid
Palmiticacid
Tinuvin234
UV at 220 nm
Charged Aerosol Detection
A B
0 0.5 1 1.5 2
Void + Cl- Propanolol
KetoprofenVerapamil
UV at 220 nm
UV at 254 nm
Charged Aerosol Detection
Hidden peaks revealed
Uniform response with charged aerosol detection• Detector response is independent of analyte structure
for all non-volatile compounds
• Excellent sensitivity coupled with wide dynamic range for unrivaled performance
• Single calibrant for quantification of multiple analytes when individual standards are not available
3
The CAD shows uniform response (<5% RSD variation) for all non-volatile analytes (0.5 µg; flow injection analysis).
0
0.5
1
1.5
2
2.5
Ace
tam
inop
hen
Rel
ativ
e R
epso
nse
Fact
or
Chl
oram
phen
icol
Cor
tison
e
D-G
luco
se
Dib
ucai
ne
Dic
lofe
nac
Diu
ron
D-P
anto
then
ic a
cid
Fluo
resc
ine
Gua
nine
Hip
puric
aci
d
Lact
ose
L-A
scor
bic
Aci
d
Mal
tose
Mefl
oqui
ne
New
coc
cine
Rho
dam
ine
800
Sacc
harin
Sucr
ose
Trip
olid
ine
Ura
cil
Urid
ine
CCAADD RReessppoonnssee ((00..55µµgg))bbyy FFllooww IInnjjeeccttiioonn AAnnaallyyssiiss
“ The LC–CAD has been shown to be effective and powerful analytical tool for the determination of synthetic cannabinoids in herbal blends without their reference standards. This method can be applied to legal highs control and for risk assessment of their presence on the market.”
Professor Zbigniew Fijalek, Department of Bioanalysis and Drug Analysis, Warsaw Medical University
Quantify your sample
FocusJetConcentricNebulizer
Gas Inlet
Inletfrom
ColumnIon Trap
Electrometer
Gas Exhaust
Micro Drain Pump
Evaporation Tube
Mixing Chamber
Corona Charger
Charged aerosol detection is a technique capable of measuring any non-volatile and many semi-volatile species. The technology provides more universal detection than UV, which requires a chromophore or mass spectrometry, which requires formation of gas phase ions.
With charged aerosol detection the eluent stream is nebulized, and the droplets are dried to produce analyte particles that are subsequently charged. This technology provides excellent response uniformity since particle charging is effectively independent of a compound’s physicochemical properties.*
Due to its exceptional response uniformity the CAD can be used to quantify multiple analytes using a single calibrant. Single calibrant quantitation is extremely useful when specific analyte standards are unavailable. For example, the response curve of an active pharmaceutical ingredient (API) can be used to determine levels of unknown impurities.
* CAD response is very similar for a given absolute mass of any nonvolatile analyte. Additional correction may be needed for analytes with ionizable functional groups.
Three simple stepsNebulization Charged aerosol detection begins by nebulizing the eluent into droplets, which are subsequently dried into particles. The particle size increases with the amount of analyte.
Charging A stream of charged nitrogen gas collides with the analyte particles. The charge is then transferred to the particles—the larger the particle, the greater the charge.
Detection The charged particles are transferred to a collector where the aggregate charge is measured by a highly sensitive electrometer. This generates a signal directly proportional to the quantity of analyte present.
4
1
1
2
3
2
Schematic of CAD technology
Signal is directly proportional to the
analyte quantity
3
SEE TN72806 FOR ADDITIONAL DETAILS
LEARN MORE ABOUT CAD
Understanding charged aerosol detection
The Thermo Scientific™ Vanquish™ Charged Aerosol Detectors and Thermo Scientific™ Corona™ Veo™ Charged Aerosol Detectors provide:
• Simple, intuitive operation
• Wide linear and dynamic range
• Sub-nanogram sensitivity
• Method flexibility covering micro-flow HPLC and UHPLC applications with a single nebulizer
• Adjustable evaporation temperature to optimize signal-to-noise ratio
5
Vanquish Charged Aerosol Detector
Adjust the evaporation temperature to optimize method performance. The effects of evaporation temperature on the signal-to-noise ratio of metoprolol and and impurities are presented here.
Metoprolol impurity testing using United States Pharmacopoeia method USP 41(3)
Corona Veo Charged Aerosol Detector
14
12
10
8
6
4
2
0Metoprolol
35 °C
Evaporation temperature
50 °C
70 °C
ImpurityA
ImpurityC
Sign
al-to
-Noi
se R
atio
SEE AN72763 FOR GREATER DETAIL
B
Metoprolol AC
Succinate
IH
Impurity of H
0 2 4 6 8 10 12
Time [min]
-1
10
20
30
40
Cur
rent
[pA
]
Introducing the modules
6
UHPLC-CAD is a powerful tool used throughout drug discovery and development
• Simultaneously measure anionic and cationic counterions, APIs and impurities
• Determine purity, mass balance, and the stoichiometry of drug formulations
• Speed selection of final product formulations
Many proteins and active biopharmaceutical ingredients possess a chromophore allowing for conventional HPLC with UV/Vis detection. However, there are many instances where the biotherapeutic agent is UV active, but the UV-transparent excipients and critical non-chromophoric natural or chemical modifications to the compound must be detected and measured.
Simultaneous measurement of organic and inorganic counter-cations and counter-anions
Profiling surfactants is made possible with charged aerosol detection. Quantification methods are also available.
Label-free analysis of N-linked Glycans by UHPLC-CAD in PNGase F Digests
PHARMACEUTICAL
BIOPHARMACEUTICAL
Cleaning Validation
Compendial Methods
Compound Management
Excipients
Extractables/Leachables
Formulation
Adjuvants
Biosimilars
Conjugation
Drug delivery
Excipients
Extractables/Leachables
Formulation
Lot-to-Lot Variability
Liposomes
N-linked Glycans
O-Linked Glycans
PEGylation
Product Characterization
Sialic Acid
siRNA Delivery Vehicles
Surfactant Quantitation and Profiling
Tryptic Digests
Library QC
Mass Balance
Method Development
Method Transfer
Method Validation
NIST
Purity Testing
QA/QC
Quality by Design
Safety Testing
Stability Testing
Surfactants
0 5 10 15 20 25 30 35-5.4
0
5
Mon
osia
lylat
ed
Dis
ialyl
ated
Dig
est R
eage
nts
Tris
ialyl
ated
Tetr
asia
lylat
ed
Alditols Standard
Fetuin
α1-Acid Glycoprotein
Cur
rent
[pA
]
Time [min]
0 5 10 15 20 24.2
Time [min]
–2.2
10
20
30
40
49.5
Cur
rent
[p
A]
pA
Lact
ate
Pro
cain
e
Cho
line
Trom
etha
min
eS
odiu
mP
otas
sium
Meg
lum
ine
Mes
ylat
e
Glu
cona
te
Mal
eate
Nitr
ate
Chl
orid
eB
rom
ide
Bes
ylat
eS
ucci
nate
Tosy
late
Pho
spha
te
Mal
ate
Zin
c
Mag
nesi
umFu
mar
ate
Tart
rate
Citr
ate
Cal
cium
Sul
fate
1612 20
PEG (MW~300)
PEG (MW~400)
PEG (MW~600)
PEG (MW~1000)
0 84
0
80
Cur
rent
[pA
]
Time [min]
LEARN MORE ABOUT THE VARIOUS APPLICATION AREAS OF CHARGED AEROSOL DETECTORS
LEARN MORE ABOUT BIOPHARMA
See what you’ve been missing
LipidsLipids, including fats and oils, contain molecules with a wide variety of structural properties and are found throughout many products and industries. These compounds are traditionally difficult to characterize with conventional detection technologies. Charged aerosol detection is a powerful tool for lipid analysis due to its structure-independent response.
CarbohydratesTraditional approaches for studying sugar fingerprints in foods can be limiting, often utilizing dedicated equipment. The CAD offers the flexibility to use gradient HILIC modes of separation with the simplicity of dilute-and-shoot on any LC system.
Industrial water treatment Polyacrylic acid, a biodegradable water soluble polymer and environmentally toxic agent, is used as an anti-scaling inhibitor in circulating water systems. The low levels present in water samples are difficult to characterize using standard methods. This example shows detection by a CAD at low ppb levels.
Targeted approach: triacylglycerol measurement in pomace Metabolomic approach: differences in triacylglycerol patterns measured by Principal Component Analysis can be used to determine product authenticity and adulteration. Figure shows ability to detect extra virgin olive oil (EVOO) adulteration.
0.3 5 10 15 20 25 30 35 38.2
Time [min]
Cur
rent
[pA
]
-50
0
50
100
150
200
250
300314
ECN42 ECN44 ECN46 ECN48 ECN50
ECN = Equivalent Carbon Number
L = Linoleic Acid
O = Oleic Acid
P = Palmitic Acid
S = Stearic Acid
OLL OO
Ln+
OLP
oLL
P OLn
P+
PLP
oO
OL+
PLn
P
OO
Po
OLP
+S
LLP
OP
o
OO
O+
PP
oP
OO
P PO
P SO
O
SO
P
AO
O
LLP
oLL
nP
LLL
Pomace Oil Triacylglycerol Separation
FOOD AND BEVER AGE
ENVIRONMENTAL / INDUSTRIAL
Adulteration
Antifoaming Agents
Antioxidants
Artificial Sweeteners
Authentication
Botanicals
Carbohydrates
Electrolytes
Emulsifiers
Lipids
Natural Products
Stabilizers
Supplements
Surfactants
Traditional Medicines
Vitamins
Algal oil
Biodiesel
Biomass analysis
Composting
Descaling agents
Fracking
Gas well additives
Industrial polymers
Ionic liquids
Light stabilizers
Metal working oils
Oil well additives
Pesticides
PFCAs
Plating bath additives
Silicone oils
Surfactants
Total dissolved solids
Xenoestrogens
UHPLC characterization of sugars in apple juice
Polyacrylic acid in cooling water
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.50-2
20
40
60
80
100
130
Cur
rent
(pA
)
Time (min)
Fructose
Sorbitol
Glucose
Sucrose
-10 -5 0 5 10
Factor 1
-8
-4
0
4
8
Fact
or 2 50% P
50% H
EVOO-1
75% P
75% H
100% Pomace
100% Hazelnut Oil
EVOO-2
25% C
50% C
75% C
100%Corn Oil
25% P
25% H
Printed with permission from Dr. Paolo Lucci and Prof. Lanfranco Conte; University of Udine, Italy
0 1 2 3 4 5 6 7 8 9 10 11
-0.100
0.125
0.250
0.375
0.500
0.625
0.800
Cur
rent
(pA
)
Time (min)
6
5
4
3
2
1
Polyacrylic acid
Cou
nter
-ion
salts
2500–50 pg on-column
Counter-ion
7
88
The Vanquish solution A Vanquish charged aerosol detector opens new opportunities for discovery and routine analysis. Utilize the charged aerosol detector with the increased separation speed and resolution of the Vanquish UHPLC systems for a worry-free, perfectly integrated chromatographic system.
Easy integration with any LC system
The Corona Veo detector is designed to integrate into any liquid chromatographic system, HPLC or UHPLC, from any manufacturer. The stackable design and rugged construction allows positioning anywhere within a system.
The UltiMate 3000 solution
Combine the Corona Veo detector with the Thermo Scientific™ UltiMate™ 3000 LC system to benefit from the extended detection capabilities for your analytical workflows and see more than before.
Complete the installation
9
Detector response for 18 reference standards for container extractables using a multi-detector set-up for comprehensive quantitative sample analysis
Combine UV/Vis detection, with CAD and MS detection for comprehensive quantitative sample analysis
Comprehensive sample analysis—more data and results in a single runThe seamless combination of complementary detectors in a single platform produces a powerful tool for the in depth characterization of complex samples. UV detection extends the range of compounds measured by the CAD to include volatile compounds. Complementary MS detection is used to confirm compound identity or for tentative identification of unknowns.
Use the multi-detector platform for:
• Thorough analysis of complex drug formulations
• Rapid evaluation of compound purity
• Quantitation and identification of impurities, degradants and contaminants
• Quantitation even when standards are unavailable using a single calibrant
All in a walk-up system with Thermo Scientific™ Chromeleon™ XPS Open Access software delivering a very streamlined interface that harnesses the full power of Chromeleon CDS.
Ana
lytic
al C
olum
n
Col
umn
Com
part
men
t
Diode Array Detector
Split Sampler
PumpPump
34
615
2
Charged AerosolDetector
InjectionValve
Flow Splitter
MS Detector
Diverter Valve
LEARN MORE DETAILS
Analyte UV CAD MS
Phthalide • •Phthaldialdehyde • •BHET • • •Dimethyl phthalate • •Bisphenol A • •Butylparaben • • •Tinuvin P • •Azobenzene • •2,4-di-t-butylphenol •BHT •Palmitic acid • •Erucamide • •Stearic acid • •Tinuvin 234 • • •Irganox 1010 • • •Irgafos 168 • • •Eicosane •Tetracosane •
Multi-detection
10
Flow Path 1 Recondi-tioning
Recondi-tioning
Single Channel LC
Analytical GradientApplication 1
Analytical GradientApplication 1
Flow Path 1Flow Path 2
Recondi-tioning
Recondi-tioning
Inverse Gradient Method — Improved quantification with CAD
Analytical GradientApplication 1
Analytical GradientApplication 1
Calibration curves for four pharmaceuticals without (left) and with (right) inverse gradient compensation (right) showing similar response curves for all compounds
An inverse gradient delivered by the left pump ensures that the composition of the mobile phase entering the detector remains constant thereby maintaining response uniformity
4
3
2
1
0
Mass on Column (ng)
● Adenine
● Tenofovir
● Emtricitabin
● Tenofovir Disoproxil
● Adenine
● Tenofovir
● Emtricitabin
● Tenofovir Disoproxil
0 10 20 30 40 50
Pea
k A
rea
(pA
*min
)
4
3
2
1
0
Mass on Column (ng)0 10 20 30 40 50
Pea
k A
rea
(pA
*min
)
4
3
2
1
0
Mass on Column (ng)
● Adenine
● Tenofovir
● Emtricitabin
● Tenofovir Disoproxil
● Adenine
● Tenofovir
● Emtricitabin
● Tenofovir Disoproxil
0 10 20 30 40 50
Pea
k A
rea
(pA
*min
)
4
3
2
1
0
Mass on Column (ng)0 10 20 30 40 50
Pea
k A
rea
(pA
*min
)
Improve your quantitation without limitation The response of the CAD is independent of an analyte’s chemical structure, but is dependent upon the organic content of the mobile phase. Uniform response of the CAD is therefore affected by changes in solvent composition during gradient elution.
In order to use single calibrant quantitation, changes in detector response during gradient elution needs to be minimized. This is easily achieved using a secondary make up flow post column. This inverse gradient ensures that the detector “sees” a constant mobile phase composition thereby ensuring uniform response.
The Thermo Scientific™ Vanquish™ Duo UHPLC system for Inverse Gradient provides:
• Confident uniform response with gradient elution using dual pump technology
• Reliable single calibrant quantitation of knowns and unknowns independent of gradient composition
• Simplified method setup with automatic inverse gradient calculation considering all system volumes
Ana
lytic
al C
olum
n
Col
umn
Com
part
men
t
Dual Pump set-up with optical detector
Optical DetectorVWD, DAD, FLD
Split Sampler
Dual PumpPump left Pump right
34
61
2
Charged AerosolDetector
15
Vanquish Duo System for Inverse Gradient
No extra work needed— automatic gradient implementation Chromeleon CDS automatically identifies the inverse gradient instrument configuration and starts the dedicated method wizard. The wizard calculates and applies the inverse gradient to the second pump in the Vanquish Duo System for Inverse Gradient taking into account all internal volumes giving highest quantitation accuracy and maximized ease-of-use.
Chromeleon CDS guides users through the implementation of an inverse gradient method with automatic system volume considerations and gradient formation
Response of the CAD is dependent upon mobile phase composition during a gradient (red bars). An inverse gradient overcomes the effect of the gradient (gray bars) on detector response.
Quantitation accuracy of unknowns using a single calibrantThis requires detector response to be independent of chemical structure:
• UV response depends on the strength of the chomophore, which in turn, is dependent on chemical structure
• CAD response for non-volatiles is independent of chemical structure but does depend upon mobile phase composition
• CAD with an inverse gradient approach results in uniform response that is ideal for single calibrant quantitation
11
0
100
200
low organiceluter
medium organiceluter
high organiceluter
low organiceluter
medium organiceluter
high organiceluter
Charged Aerosol Detector Charged Aerosol Detector withInverse Gradient
Res
pons
e
LEARN MORE ABOUT VANQUISH DUO UHPLC
Find out more at thermofisher.com/CAD
© 2013–2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. BR70735-EN 1218M
Find out more about CAD and many other applications in the Thermo Scientific™ AppsLab Library of Analytical Applications and see how the combination of Thermo Scientific HPLC and UHPLC systems using CAD with the Chromeleon Chromatography data system (CDS) is delivering productivity gains.
AppsLab Library of Analytical Application
LEARN MORE ABOUT APPSLAB LIBRARY
As a trusted chromatography provider for more than three decades, we are proud to offer unique and highly productive solutions for your future-proof and forward-looking investment. Everything you need is within easy reach to boost the overall productivity of your laboratory.
Separate your science from the status quo
Vanquish Duo Systems
Vanquish Horizon System
Vanquish Flex Systems
Thermo Scientific™
EASY-nLC™ 1200 System
UltiMate 3000 RSL Cnano System
UltiMate 3000 RS and BioRS Rapid Separation System
UltiMate 3000 Standard System
UltiMate 3000 Basic System
UHPLC/MS SolutionsChromeleon CDS
Thermo Scientific™ Viper™ Fingertight Fittings System
Thermo Scientific™
Acclaim™ Trinity Columns
LC Columns
Thermo Scientific™
Accucore™ Columns
Vanquish and Corona Veo Charged Aerosol Detectors