BY SOPHIA VIJAYANANTHAN JUNIOR LECTURER COLLEGE OF NURSING,CMC,VELLORE
DISINFECTION & STERILIZATION STERILIZATION
Process of removing microbes inclusive of bacterial endospores
DISINFECTION process of removing microbes except bacterial endospores
DISINFECTIONCHEMICALS:disinfection or sterilization DISINFECTANTS: low level intermediate level high level
STERILIZATIONPhysical method
Heat
Radiation
Dry heat
Moist heat(autoclave)
Prevaccum
Gravity displacement
CHEMICAL METHOD
2% GLUTARLDEHYDE
8-10 Hrs used for :Pneumatic circuits. i.e.ventilator tubing O2 masks ventury devices nebulizer chamber
Sterilization
Disinfection15-30 Mts used for dis infecting endoscopes Respiratory tubing's
ETHYLENE OXIDE(EO)Used for polythene and plastic itemsE.g.:- Ambu bag ,Baines circuit , Domes ,
Biopsy Needle , Electric items , Rubber items
E.O. GASPre-caution: Scrupulous cleanliness and dryness Adequate aeration at least 12Hrs
VENTILATOR STERILE WATER FOR NEBULIZER & HUMIDIFIER PNEUMATIC CIRCUIT TO BE CHANGED WHEN VISIBLY SOILED USE HEAT & MOISTURE EXCHANGE FILTER CONDENSATE IN TUBING TO BE DRAINED ONLY TO THE WATER TRAPS
HUMIDIFIER DOMES (AUTO CLAVED OR STERILIZED BY 2% GLUTARALDEHYDE)
PNEUMATIC CIRCUIT WASHED UNDER RUNNING WATER IMMERSED IN 2% GLUTARALDEHYDE FOR 8 TO 10Hrs
TRACHEOSTOMY CARETO BE GIVEN EVERY FOUR HOURS SKIN AROUND TRACHEOSTOMY TUBE CLEANED WITH BETADINE INNER CANNULA OF METAL TRACHEOSTOMY -CLEANED UNDER RUNNING WATER
-IMMERSED IN HYDROGEN PEROXIDE FOR 10MTS- WASHED WITH WATER AND GAUZE WICK -BOILED FOR 10 MINTS AND REPLACED ONCE IT IS COOL
TRACHEAL SUCTIONINGUSE DISPOSABLE SUCTION CATHETER SUCTION JAR & TUBING CHANGED EVERY 24 Hrs
FILLED WITH 7% LYSOL FOR 1Hr
CLEANED WITH SOAP UNDER RUING WATER
SUCTION TRAYSo TO BE CHANGED EVERYDAY o SUCTION CUPS-CHANGED AFTER EACH USE - IMMERSED IN 7% LYSOL FOR 1Hr - WASHED WITH SOAP &WATER - SENT FOR AUTOCLAVING
ICU ISOLATION ROOMSINGLE CLOSED CUBICLECASES OPEN TB , ANTHRAX, MRSA etc UV LIGHT FOR DISINFECTION
FUMIGATION
NOT RECOMMENDED
ICU INSTRUMENTSSEPARATE:THERMOMETER, AMBU BAG,BAINS CIRCUIT, STETHOSCOPE, BIOPSY NEEDLE - EO GAS STERILIZATION DISPOSABLE SUCTION CATHETER
ALL REUSABLE ITEMS
WASHED UNDER RUNNING WATER
2% GLUTARALDEHYDE
DOUBLE AUTO CLAVING1. HIV , HBV , HCV , MRSA INFECTTION 2. FOR RE- USABLE NON SHARP MATERILE
3. PLACED IN REDBAG
PERSONNELUNIVERSAL PRECAUTION
HAND WASHING
GLOVES
MASK
SHARPS
LINENo SOAKED IN 7% LYSOL hrs
SEPARATE AREA (UTILITY ROOM) FOR EQUIPMENT DISINFECTION PNEUMATIC CIRCUITS , O2MASK etc SUCTION JAR CLEANING AND DISINFECTION CHEST DRAINAGE BOTTLES LINEN DISINFECTION
ROUTINE SURVEILLANCE IN ICU ONCE IN A MONTH