42
Dividing Wall Columns in Petrochemical Industry “Taking Advanced Distillation into the Modern Era” Manish Bhargava - Director Advanced Distillation GTC Technology K Shreya BPCL Mumbai ADVANCED DISTILLATION

DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Embed Size (px)

Citation preview

Page 1: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Dividing Wall Columns in Petrochemical Industry

“Taking Advanced Distillation into the Modern Era”

Manish Bhargava - Director Advanced Distillation GTC Technology

K Shreya – BPCL Mumbai

ADVANCEDDISTILLATION

Page 2: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Dividing Wall Columns ( GT-DWC )

Page 2

Most of the energy consumed in refineries is related to distillation.

Advanced separation techniques make substantial reductions in

energy consumption and improvement in product specifications

• GT-TDWC: Top Dividing Wall Columns

• GT-DWC℠: Middle Dividing Wall Columns

• GT-BDWC: Bottom Dividing Wall Columns

• GTC Single Shell Absorption / Distillation Column

Page 3: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Press Announcement

Page 3

BPCL started 1st Top Dividing

Wall Column in Isom Unit at

Mumbai in March 2017

Page 4: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Heat Integrated GT-TDWC℠

Page 4

• Conventional side draw column provides limited opportunity for heat

integration

• Top dividing wall column gains the thermodynamic efficiency, plus

affords meaningful heat integration.

A

C

Feed

(A,B,C)

B

Feed

(A,B,C)

BA

C

Conventional Sidedraw Column GT-TDWC℠

From Process

Page 5: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 1: GT-TDWC℠ for Food Grade

Hexane Production (FGH) for BPCL, India

Page 5

FGH production requires a narrow cut of an intermediate

product.

Options for application

• Conventional 2 Column System : DIH + FGH column

• Advanced Distillation Option : GT-TDWC

Page 6: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Conventional Option: DIH +

New FGH Column

Page 6

FGH

Product

DIH

Co

lum

nLight

Isomerate

Stable

Isomerate

FG

H C

olu

mn

Heavy

IsomerateTotal Isomerate

Page 7: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Comparison: GT-TDWC℠ vs

Conventional 2-Column System

Page 7

DIH ColumnNew

FGH Column

52.4 17.0

Operating Cost

(MM USD/year )

Steam only

7.369.69

GT-TDWC℠

Conventional

2 Column System

MP Steam Consumption

(1000 x lb/Hr)52.90

Total = 69.4

Page 8: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Top Dividing Wall Column

Installation at BPCL, India

Page 8

Page 9: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Dividing Wall Columns ( GT-DWC )

Page 9

Most of the energy consumed in refineries is related to distillation.

Advanced separation techniques make substantial reductions in

energy consumption and improvement in product specifications

• GT-DWC℠: Middle Dividing Wall Columns

• GT-TDWC: Top Dividing Wall Columns

• GT-BDWC: Bottom Dividing Wall Columns

• GTC Single Shell Absorption / Distillation Column

Page 10: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 2:

• Three Cut FCC Naphtha Splitter revamped to GT-DWC

Page 10

Page 11: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Confidential

Existing Naphtha Splitter Configuration

Page 11

Cut Point Range

288 to 388˚F

Depentanizer Bottoms

Cut Point Range

161 to 373˚F

Cut Point range

147 to 212˚F

Cut Point Range

223 to 376˚F

Page 12: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Objectives for Revamp

• Increase Feed rate

• Reduce overlap of heavier components in side cut

• Keep LCO and HCO as the heating medium for the

column.

Page 12

Page 13: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Bottlenecks in Column Design

with Reference to New Objectives

Page 13

Intermixing of Feed with

Side Cut

Smaller Diameter puts a

restriction on Vapor/Liquid

Loading

Heavies

Product

Feed

Overhead

Product

Sidecut

Product

LCO

HCO

Page 14: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Revamp to GT-DWC℠

Page 14

Heavies Product

Feed

Overhead Product

Sidecut

Product

Sidecut separated

from feed;

Better quality

Page 15: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Dividing Wall Column Trays

Page 15

Page 16: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Installation of Dividing Wall

Page 16

Page 17: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Internal Liquid Split Distributer

Provision for external

splitting for future use

Risers for

vapor flow

Liquid split metering box

(Maintains fixed liquid ratio

on either side of wall)

Page 17

Page 18: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Product Specs after Revamp to GT-DWC℠

Page 18

Parameter UnitsNaphtha Splitter

before Revamp

Napththa Splitter

after Revamp

to GT-DWC℠

Side Draw Flow Rate lb/hr 398,000 353,000

D86 (IBP/FBP) Deg˚ F 223 to 376 231 to 356

Overlap (Heart Cut Naphtha

D86 95%-Heavy Cut

Naphtha D86 5%)

Deg˚ F99 27

Page 19: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Project Economics

Page 19

• Client was planning to install a 2nd column in sequence

with the existing Naphtha Splitter.

• A spare column was available for this retrofit.

• Cost of Revamp to GT-DWC℠ was 1/4 of the alternate

two-column design being explored by the client.

Page 20: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 3 :

Page 20

Existing Two Column FCC Naphtha Splitter Sequence

revamped to GT-DWC℠

Page 21: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 3: Two Columns Modified to

Single Column

Feed

C5 Naphtha

HCO /

HP Steam

LCO

Heart Cut

Naphtha

HCO

Heavy

Naphtha 1

Heavy

Naphtha 2

LP Steam

Generator

BFW

Page 21

Page 22: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Confidential

Design Features in Original Configuration

• Use of low temperature heat duty via LCO in NS1. This

requires a side reboiler in NS1 Column

• Minimize duty in NS1 by taking a side cut stream to NS2

column

• Elevate pressure of NS2 Column to generate LP steam

Page 22

Page 23: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Confidential

Design Features in Original Configuration - Use of Low

Temperature Heat Duty via LCO in NS1

Page 23

NS1 Column has a side reboiler

which allows use of low

temperature heat duty

The side reboiler forces a higher

loss of C8s in the top product as

the bottom section trays remain

under utilized.

Feed from

Depentanizer

Light Naphtha

LCO

44 MMBtul/hr

Heavy Oil

54 MMBtu/hr

Heavy Naphtha

C8/C9

Page 24: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Confidential

Design Features in Original Configuration - Minimize Duty

in NS1 by Taking a Sidecut to NS2 Column

Page 24

A Side stream as feed to NS2

Column lowers the energy

consumption in NS1

A Sidecut from NS1 forces

higher C9 loss in Heavy

Naphtha bottoms product

Feed from

Depentanizer

Light Naphtha

LCO

44 MMBtu/hr

Heavy Oil

54 MMBtu/hr

Heavy Naphtha

C8/C9

Page 25: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Confidential

Page 25

LP Steam

generator

Heavy Naphtha

Heavy Oil /

HP Steam

Heart Cut

Naphtha

NS2 Column pressure is elevated

to generate LP steam from the

overhead vapors

Higher operating pressure

decreases the relative volatility

between different components

LP steam is generated at the

expense of higher HP steam and

hot oil consumption

Design Features in Original Configuration - Elevate

Pressure of NS2 Column to Generate LP Steam

Page 26: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Revamp to GT-DWC℠

Heavy

Naphtha

Feed

Light

Naphtha

LCO

HCO

Heart Cut

Naphtha

Naphtha Splitter-1 Revamped to GT-DWCSM Naphtha Splitter II Idled

Heavy

Naphtha 2

HCO /

HP Steam

Heart Cut

Naphtha

LP Steam

Generator

Page 26

Page 27: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Benefits of Revamp to GT-DWC℠

• Reduce utility consumption for the separation.

• Produce heart cut naphtha in Naphtha Splitter-1 column,

while removing Naphtha Splitter-2 from service.

Parameter UnitsOriginal Design

(NS-I and NS-II)

Naphtha Splitter-I

after Revamp to

GT-DWC℠

Feed lb/hr 679,000 679,000

Side Draw Flow Rate lb/hr 363,700 363,500

D86 (IBP-FBP) ˚ F 231-338 231-337

Overlap (Side Cut D86 95%-

Heavy Cut Naphtha D86 5%)˚ F 8.1 7.0

Total Heating Duty MMBtu/hr 151 111

Page 27

Page 28: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Parameter UnitsOriginal Design

(NS-I and NS-II)

Naphtha Splitter-I

after Revamp to

GT-DWC℠

Feed lb/hr 679,000 679,000

C8/C9 (Naphthenes & Aromatics) lb/hr 243,900 243,900

Mid Cut lb/hr 363,700 363,500

C8/C9 (Naphthenes & Aromatics)

Concentrationwt% 63.90 66.53

C8/C9 (Naphthenes & Aromatics) lb/hr 232,404 241,860

% Recovery C8/C9 (Napthenes & Aromatics) wt% 95 98

Loss of C8/C9 (Naphthenes & Aromatics) lb/hr 25,280 18,230

Total heating duty MMBtu/hr 151 111

Comparison : Product Recoveries

Existing Configuration vs GT-DWC

Page 28

Page 29: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Benefits of GT-DWC℠

• Heating duty reduced by ~ 26%

• HP steam usage eliminated

• Naphtha Splitter-II is idled

• 3% Higher Product recoveries

• Heart Cut Naphtha obtained in Naphtha Splitter-I

• Project Payback (Based on Energy Reduction benefits only) = 10 Months

Page 29

Page 30: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 4: Grassroots Mixed Xylenes

Recovery Unit at TonenGeneral (TG), Japan

• TG had an existing unit which produced C7+ product for gasoline

blending.

• TG wanted to separate high purity petrochemicals (Toluene,

Mixed Xylenes) from the feed.

• TG decided for a DWC solution against a two column

configuration because of lower CAPEX and lack of plot space.

Page 30

Page 31: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 4: Mixed Xylenes Recovery

Page 31

Page 32: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GT-DWC℠ for Mixed Xylenes Recovery

Reformate

Feed GT-DWC

ColumnReformate Light

Cut ColumnReformate Heavy

Cut Column

C5 rich

CutC6 Rich Cut

to Aromatics

Toluene

Mixed

Xylenes

C9+ CutClay Treaters

Page 32

Page 33: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Page 33

Toluene

Mixed

Xylenes

C9+ Cut

Feed from

Clay Treaters

#17

#103

TIC

FIC

TIC

Reformate Light

Cut Reboiler

Reformate Heavy

Cut Reboiler

TX DWC is defined by three

primary control loops

• Fixed reflux rate

• Side draw product rate

cascaded to TI on upper tray

• Heating Duty cascaded to

bottoms temperature

Primary Control Scheme

GT-DWC

Column

Page 34: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GT-DWC℠ Column Internals at TonenGeneral

Page 34

Off Center

Dividing Wall

Page 35: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

TonenGeneral Mixed Xylenes Recovery Unit

Page 35

• Installation of GT-DWC℠ Column at Chiba Refinery, Japan

Page 36: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Comparison : Two Column System vs DWC

Page 36

Product SpecificationsTwo-column

sequence

DWC

configuration

Mix-xylenes product, lb/hr 64,665 64,670

C8 aromatics, wt% 99.2 99.3

Reboiler duties, MMBtu/hr 85.6 68.2

Steam Reduction, 1000 x lb/hr - 42.0

Operating cost savings, % - 25

Capital cost, $ million 26.0 21.0

Page 37: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Case Study 5:

GT-LPG MAX℠ for LPG Recovery

Page 37

Client Objectives

• Propane recovery in LPG > 97%

• No Refrigeration

Page 38: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Page 38

Off Gas

(C1,C2, C4,

C4,Heavies)

Fuel Gas

(C1,C2)

450 psig

LPG (C3)

C4, Heavies

300 psig

• LPG Recovery - 55%

• Energy - 22 MMBtu/hr

Conventional Design of LPG Recovery Unit

Page 39: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Page 39

Off Gas

(C1,C2, C4,

C4,Heavies)

Fuel Gas

(C1,C2)

LPG (C3)

C4, Heavies

Operating pressure = 300 psig

• LPG Recovery - 97%

• Energy - 20 MMBtu/hr

Internal Circulation of Heavies

as Absorption Solvent

GT-LPG MAX℠ - Combined Absorption &

Distillation in a Single Column

Page 40: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Project Economics of GT-LPG MAX℠

Page 40

VariablesExisting

ConfigurationGT-LPG Max℠

Overall Propane

Recovery %55 % 97 %

Total Duty MM Btu/hr 22.0 20.0

Page 41: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

Summary

Page 41

• Unconventional distillation applications are an overlooked means to

reduce refinery energy consumption

– GT-DWC℠ reduces 20–30% OPEX through energy savings

– GT-DWC℠ reduces 20–30% CAPEX by requiring a single column

for multi-component separation

• Advanced Distillation schemes can offer CAPEX and OPEX reduction

of more than 40% by combining multiple unit operations and heat

integration opportunities.

Page 42: DISTILLATION Dividing Wall Columns in Petrochemical Industry · Dividing Wall Columns in Petrochemical Industry ... energy consumption and improvement in product specifications

GTC Technology