Distribution Category: LMFBR Safety (UC-79p) ANL-78-105 ARGONNE NATIONAL LABORATORY 9700 South Cass Avenue Argonne, Illinois 60439 ICEPEL ANALYSIS OF AND COMPARISON WIIH SIMPLE ELASTIC -PLASTIC PIPING EXPERIMENTS by M. T. A-Moneim Reactor Analysis and Safety Division NOTICE Ti supon wans vpouwd a cco-at of -ork sponued by dhe Uneid Stae Goen.iernt. enPhe r he Ummid Stain nor the Umeed Sates i patmni of Emer. mna say of her Onioysm. nor say of then coal-iscis. abcorctors, 4 thuemploy , ma kes any wraty. raeor yed. or a .an y kpl tlssbitsiy o r mpsnodity foe the ccr"cy. co npkheeawr aufwoofmy infoewmatoen. apphratui. psdsst or proessdincbrd. or mpwnrn that ts in would notl niru n.yoweud nmils December 1978

Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

Distribution Category:LMFBR Safety (UC-79p)

ANL-78-105

ARGONNE NATIONAL LABORATORY9700 South Cass AvenueArgonne, Illinois 60439

ICEPEL ANALYSIS OF AND COMPARISON WIIHSIMPLE ELASTIC -PLASTIC PIPING EXPERIMENTS

by

M. T. A-Moneim

Reactor Analysis and Safety Division

NOTICETi supon wans vpouwd a cco-at of -ork

sponued by dhe Uneid Stae Goen.iernt. enPhe r heUmmid Stain nor the Umeed Sates i patmni ofEmer. mna say of her Onioysm. nor say of thencoal-iscis. abcorctors, 4 thuemploy , ma kesany wraty. raeor yed. or a .an y kpl

tlssbitsiy o r mpsnodity foe the ccr"cy. co npkheeawraufwoofmy infoewmatoen. apphratui. psdsst or

proessdincbrd. or mpwnrn that ts in would notlniru n.yoweud nmils

December 1978

Page 2: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in
Page 3: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

3

TABLE OF CONTENTS

Page

NOMENCLATURE . .. . . . . .... . . .. . ............... . . . . .. 8

ABSTRACT.... ............ .......... .................. 9

I. INTRODUCTION................................ .. 9

II. DESCRIPTION OF EXPERIMENTS . . . . . ... . . .. .... . . . . 10

A. Straight-flexible-pipe Tests . . . . . .... . . ...... . . . . 10

B. Single-elbow Loop Tests . . . . . . . . . . . . ... . . .. . . .. . . 11

III. DISCUSSION OF EXPERIMENTAL RESULTS.. .. . . ... . .... 13

A. Straight-flexible-pipe Tests . . .. . . . . . . .. . ... .. . . . . 13

B. Single-elbow Loop Tests . . . . . . . . . . . . . . . . . . . . ... . . 15

IV. ICEPEL ANALYTICAL MODELS.. .. . . . . . . .. ........... 18

V. PIPE-WALL MATERIAL PROPERTIES . ... ... . . .. .. .... 21

VI. COMPARISON OF ANALYTICAL AND EXPERIMENTALRESULTS....................................... 22

A. Straight-flexible-pipe Tests . . ... . .... ................ 22

B. Single-elbow Loop Tests . . ... .. . .. ..... . ........... 31

VII. MODIFICATION OF ICEPEL ELBOW MODEL . .. .......... 41

VIII. CONCLUSIONS AND RECOMMENDATIONS . . .... . . .... .. 48

APPENDICES

A. Effect of Pipe-wall Thickness on Circumferential Strains. . . . 50

B. Effect of Pipe Material-properties Representation onICEPEL Calculations . . .. . . . . . . . . . . . . . . . . . . . . . . . . 54

C. Effect of Zone Size and Time Step on ICEPEL Calculations. . . 55

ACKNOWLEDGMENTS . ...... . . . . . ....... . . . . . . . . . .. . 59

REFERENCES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Page 4: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

4

LIST OF FIGURES

No. Title Page

1. Layout for Straight-flexible-pipe Tests.. . ... ... ............ 10

2. Layout for Single-elbow Loop Tests . ...... ... ...... .. . .... 12

3. Peak Pressure and Pipe-wall Deformed Shape for

Straight-flexible-pipe Tests... .. . . .... ................. 13

4. Peak Pressure and Pipe-wall Deformed Shape for

Single-elbow Loop Tests .. . ... . . . ..... .... .. . .... ...... 16

5. ICEPEL Model of Straight-flexible-pipe Tests. . .. . . ... . . .. 18

6. ICEPEL Model of Single-elbow Loop Tests.............. ..... 19

7. Stress-Strain Curves for Nickel-200 . . . . . . . . . . . . .. .. . . . . 21

8. Input Pressure Pulses for Tests FP-SP-101 and -102. ........ . 23

9. Comparison of Analytical and Experimental Pressure Historiesat Location P2 in Thick-walled Pipe...... . .................. 23

10. Comparison of Analytical and Experimental Pressure Histories

at Location P3 of Thick-walled Pipe . . . . . . . . . . . . . . .. . . . . 24

11. Comparison of Analytical and Experimental Pressure Histories

at Location P4 of Flexible Pipe.. ...... ... ......... ....... 25

12. Comparison of Analytical and Experimental Pressure Histories

at Location P5 of Flexible Pipe............. . . . . . . . . . ... 25

13. Comparison of Analytical and Experimental Pressure Historiesat Location P6 of Flexible Pipe................ ..... ... 26

14. Comparison of Analytical and Experimental Pressure Historiesat Location P7 of Flexible Pipe. . ...... ..... .......... . . 26

15. Comparison of Analytical and Experimental Pressure Historiesat Location P8 of Flexible Pipe......................... 27

16. Comparison of Analytical and Experimental Pressure Historiesat Location P9 of Flexible Pipe.. . . . . . . ........ . . . . . . .. 27

17. Comparison of Analytical and Experimental Pressure Historiesat Location P10 of Flexible Pipe. . . .. . . . . . . .......... 28

18. Comparison of Analytical and Experimental Pressure Historiesat Location P11 at Blind Flange .......... . . . . . . . . . . . . . . . 28

19. Comparison of Analytical and Experimental Strain Histories atLocation SG,-SG 5 . . . . . . . . . . . . . . . . . . . ......... . . . . . 29

20. Comparison of Analytical and Experimental Strain Histories atLocation SG6 -SGiO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Page 5: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

5

LIST OF FIGURES

No. Title Page

21. Comparison of Analytical and Experimental Strain Historiesat Location SG11-SG 1 5 . . . . . . . . . . . .. . . . . . .9 . . . . . . . . . . . . . . . . . 3 0

22. Comparison of Analytical and Experimental Strain Historiesat Location SG1 6 -SG-2 0 . . . . . . . . . . . . . . . . . . . .- . . . . . . . . . . . . . . . . . . .-30

23. Input Pressure Pulses for Analytical Models of Tests FP-E-101and -103................. .............................. 31

24. Comparison of Analytical and Experimental Pressure Historiesat Location P2 of Thick-walled Pipe of Single-elbow Loop Tests. . 32

25. Comparison of Analytical and Experimental Pressure Historiesat Location P3 of Thick-walled Pipe of Single-elbow Loop Tests. . 33

26. Comparison of Analytical and Experimental Pressure Historiesat Location P4 of First Flexible Pipe of Single-elbow Loop Tests. 33

27. Comparison of Analytical and Experimental Pressure Historiesat Location P5 of First Flexible Pipe of Single-elbow Loop Tests. 34

28. Comparison of Analytical and Experimental Pressure Historiesat Location P6 of First Flexible Pipe of Single-elbow Loop Tests. 34

29. Comparison of Analytical and Experimental Pressure Historiesat Location P7 of First Flexible Pipe of Single-elbow Loop Tests. 35

30. Comparison of Analytical and Experimental Pressure Historiesat Locations P8-P10 of First Flexible Pipe of Single-elbowLoop Tests ... . ... . . .. . . .. .. . . ... . ...... .. .. .. .. 35

31. Comparison of Analytical and Experimental Pressure Historiesat Locations P14-P16 of Second Flexible Pipe of Single-elbowLoop Te sts ....... .. .f............. ..... ...... 36

32. Comparison of Analytical and Experimental Pressure Historiesat Locations P17 and P18 of Second Flexible Pipe ofSingle-elbow Loop Tests............. ...... .......... 37

33. Comparison of Analytical and Experimental Strain Historiesat Location SG,-SG 5 of First Flexible Pipe of Single-elbowLoop Tests ..... ................. .... ..... ....... 38

34. Comparison of Analytical and Experimental Strain Historiesat Location SG6 -SGIO of First Flexible Pipe of Single-elbowLoop Tests .. .. .. . .. ... .. .. .. .. .. .. .. .. .. .. . .. .. 38

35. Comparison of Analytical and Experimental Strain Historiesat Location SGI1 -SGIS of First Flexible Pipe of Single-elbowLoop Te sts . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Page 6: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

6

LIST OF FIGURES

No. Title Page

36. Comparison of Analytical and Experimental Strain Historiesat Location SG1 6-SG2 O of First Flexible Pipe ofSingle-elbow Loop Tests . . . . . .. . . ... ........... .....-.. 39

37. Elbow Cross Section.. .... . . . . .... . . .. ........ . . .. 41

38. Pipe and Elbow Hydrodynamic Coupling.......................45

39. Comparison of Analytical and Experimental Pressure Historiesat Locations P11-P 13 inside Elbow for Test FP-E-103...... . 47

A.l. Analytical Strain Histories at Locaticn SG-SG5 ,Test FP-SP-102.. . . . . . . ... . . . .. . ... . . . . . . . . . ... 50

A.2. Analytical Pressure Histories at Location P8,Test FP-SP-102. .. . .... ................... . ...... 51

A.3. Analytical Strain Histories at Location SG1 6-SGo,Test FP-SP-102................ ............... ... 51

A.4. STRAW Model of Variable-thickness Pipe............... 52

B.1. Stress-Strain Approximations for Nickel-200 . ...... . . . . .. 54

B.2. Pipe-wall Configuration at 4 ms.. . . .. .. . . .. . . .. . . . . . . 54

C.1. Wall Configuration of Flexible Pipe at 8 ms. .. .......... . .. 57

Page 7: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

7

LIST OF TABLES

No. Title Page

I. Summary of Strain Results for Straight-flexible-pipe Tests . . . . 15

II. Stress-Strain Values of Nickel-200 Used in ICEPELCalculations .............................. 22

A.l. Heights of Beam Elements of STRAW Model ofPipe Circumference .. .. . . .. .. ... . .. . . .. . ... .. .. .. 52

A.2. Calculated Strains of Thinnest and Thickest Elements atVarious Times........................... ....... 53

A.3. Summary of Measured Thicknesses and Variations inRecorded Maximum Dynamic Strain in SRI Piping Tests.. ... . 53

C.1. Summary of Input Parameters for the Five Models. . .... .. .. 55

C.2. Stress-Strain Approximation for Nickel-200 .. ..... .. . ..... 55

C.3. Peak Preseures for Models 4 and 5 . .. ......... 0... . . . . .. 58

C.4. Summary of Some Performance Parameters for ICEPEL Code.. 5858

Page 8: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

8

NOMENCLATURE

A Area

C Quantity related to the speed of sound and defined by Eq. 9

CG Quantity defined by Eq. 11

CR Quantity defined by Eq. 7

CS Quantity defined by Eq. 8

IE Number of radial zones in the elbow

IP Number of radial zones in the pipe

M Quantity defined by Eqs. 17-20

P Pressure

q Quantity defined by Eq. 4

r Radial coordinate

S Source term in difference form of z-momentum equation of the pipe

t Time

u Radial velocity component

v Axial or tangential velocity component

0 Time-centering coefficient of the mass equation

Lr Radial zone size

ot Time interval

Az Axial zone size

00 Tangential zone size

X First coefficient of viscosity

Second coefficient of viscosity

Time-centering coefficients for momentum equations

p Density

9 Ocoordinate

Subscripts

e Refers to elbow

i Counting zones in radial direction

j Counting zones in axial or tangential direction

p Refers to pipe

Superscripts

n Counting time cycles

Page 9: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

9

ICEPEL ANALYSIS OF AND COMPARISON WITHSIMPLE ELASTIC-PLASTIC PIPING EXPERIMENTS

by

M. T. A-Moneim

ABSTRACT

The results of simple elastic-plastic piping experimentsfor straight pipes and single-elbow loop systems are inter-preted and evaluated. The experiments are also analyzed by theICEPEL piping code, and the analytical results are comparedagainst the experimental data.

Good agreement is obtained in predicting both pressureand circumferential strain histories along the pipe systems.

Inside the elbow, however, the analysis showed radial pressurevariation while the experiments showed no radial pressure vari-ation. Consequently, the ICEPEL elbow model was modified toresolve this discrepancy. The new model agreed with the ex-periments in showing no radial pressure variations.

I. INTRODUCTION

Recent advances in computer technology have led to the wide use ofcomputer codes in the safety assessment of Liquid Metal Fast BreederReactors (LMFBR's) under postulated accident conditions. However, becauseof the complexity of the physical phenomena involved in the analysis, assump-tions and simplifications are usually made to calculate the consequences ofaccidental events. Such assumptions are thought of as being insignificant orleading to more conservative estimates.

To increase confidence in the use of computer codes in the safetyevaluation of reactors, and to reduce the conservatism introduced in theanalysis to reasonable limits, experimental programs designed to help verifythe analytical model and to understand the physical phenomena for betteranalytical representation must parallel the development of the analytical tools.Interpretation of the experimental data and analysis of the experiments by thecomputer codes can also help design and instrument future experiments.

The ICEPEL code is being developed at Argonne National Laboratoryfor the safety analysis of piping systems.' The code performs a coupledhydrodynamic-structural response analysis of piping systems. A two-dimensional Implicit Continuous-Fluid Eulerian finite-difference technique is

Page 10: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

10

used in the hydrodynamics.? The structural analysis treats the walls as

axisymmetric thin shells with both the membrane and bending strengths

considered. A convected-coordinates finite-element scheme is used in the

structural response calculations. 3

Two-dimensional hydrodynamic models for the different piping com-

ponents such as pipes, elbows, valves, expansions, reducers, heat exchangers,

surge tanks, and tees are included and coupled together hydrodynamically, so

that a general piping system can be modeled and analyzed both hydrodynamically

and structurally.

A piping experimental program designed at Argonne National Labo-ratory and performed by SRI International to validate the different aspectsof the ICEPEL code was undertaken. The first phase of this program con-sists of five experiments designed for the validation of the pipe and elbowmodels. 4

Two straight-flexible-pipe tests FP-SP-101 and -102 are designed to

validate the pipe model and the coupling between the hydrodynamic and struc-

tural calculations. Three single-elbow loop tests (FP-E-101, -102, and -103)

are designed to check the adequacy of the elbow model and its coupling with

the pipe model. Also, some of the basic assumptions in the elbow model are

to be evaluated from these tests.

In this report, the experimental data, as reported by SRI, are interpreted

and evaluated, the experiments are analyzed by the ICEPEL code, the analyticalresults are compared against the experimental data, the elbow model of the ICEPELcode is modified accordingly, and conclusions and recommendations for futureexperiments are discussed.

II. DESCRIPTION OF EXPERIMENTS

A. Straight-flexible-pipe Tests

Figure 1 shows the experimental layout and the locations of instru-

mentation for the straight-flexible-pipe tests, FP-SP-101 and -102. The

P, P2 31 NI 200 PIPE

Pn I P.P d P P P a P150 12 61

-0 0' s ' 24

S::Os oG0orob r$01 1GwG5 so,10 1 t G, SG 1Gt 4

Fig. 1. ,ayout for Straight-flexible-pipe Tests. Conversionfactors: 1 in. = 2.54 cm; 1 ft = 30.48 cm.

Page 11: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

11

layout consisted of a calibrated pulse gun directly flanged to a thick-walledstainless steel pipe, whichwas flanged to a flexible test pipe that ended witha heavy blind flange.

The calibrated pulse gun was developed by SRI International toproduce well-controlled and -tailored pressure pulses for testing reactorcomponents under postulated accident conditions. 5 A mixture of explosivesdetonated by PETN is used to produce pulses of sharp peaks. The pressure-peak magnitude is controlled by the mass of the explosives used. The ri'etime of the pressure peaks and the duration of the pressure pulses are con-trolled, respectively, by the clearances between the stack of washers sur-rounding the charge and the area available for venting of the explosive gases.

A mixture of 3.5 g of explosives detonated by 0.15 g of PETN consis-tently produced pressure peaks of about 16 MPa in the thick-walled stainlesssteel pipe. The rise time was about 200 ps, and the duration was about 3 ms.

The thick-walled stainless p >ct jipe was 304.8 cm (10 ft) long and of8.26-cm (3.25-in.) outside diameter. 4, wall thickness was 0.46 cm (0.188 in.).The pipe was intended to behave or 1 y iel s.;ically, so that a well-defined pres-sure pulse could be stabilized and established before entering the flexible testpipe.

The flexible test pipe was 152.4 cm (5 ft) long and of 7.62-cm (3-in.)outside diameter. Its wall thickness was 0.165 cm (0.065 in.). The pipe wasmade of nickel-200 whose stress-strain properties resemble those of Type 304stainless steel at reactor operating temperatures.

Reactor coolant was simulated by water, which filled the pipe systemat the moment of charge detonation.

All pipe flanges were heavy, well sealed, and bolted to heavy brackets,which were anchored to the ground to limit both the lateral and axial motionsof the flanges. This is a requirement of the ICEPEL code which cannot treatpipe centerline motions.

The pipe system was instrumented with 11 pressure transducersaxially distributed along the pipe system, as shown by gauges P1-P11 in Fig. 1,to monitor the pressure-pulse propagation along the system. Twenty straingauges, shown by SGi-SG2 O in Fig. 1, were used at four axial locations of theflexible test pipe to monitor the pipe dynamic response to the traveling pulses.Five strain gauges circumferentially spaced at uniform intervals of 600 wereused at each axial strain location to check the uniformity of strains aroundthe pipe circumference.

B. Single-elbow Loop Tests

Figure 2 shows the layout and the location of instrumentation for thesingle-elbow loop tests, FP-E-101, -102, and -10 3. Upstream from the elbow,

Page 12: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

12

the pipe system is identical in dimensions and material to that used in thestraight-flexible-pipe tests. A second flexible test pipe, identical in sizeand material to the first one, was connected to the other end of the elbow.

P P2 3 Ni 200 PIPE Ps

IID PIPE 13IIJ130*A 1526 311 r.:

76.2-I -16.25712 1762 1 176.2 - - 15.24 30.46

504.6 152.4 -

Pt

L4 P6152.4~S( SG, SG,0 SG6 SG,6 SG ,S ~ SG,* N 200SG6 S) 52 S~O SG, SO 14 1 )SG 13 SG II .ASG ,,PIPE I

SG3 SGe S13 SGI7.62 cm .11cm RIGID I

FROM ELBOW FROM ELBOW FLANGE PLAN VIEW

ALL DIMENSIONS IN cm

Fig. 2. Layout for Single-elbow Loop Tests

This second flexible pipe ended with a heavy blind flange in testsFP-E- 102 and -10 3. In test FP-E-101, however, the second flexible pipeended with a membrane representing a simple open-end boundary.

The 900 elbow was made of stainless steel, which was welded to shorttransition pieces that terminated in connecting flanges. The elbow radius ofcurvature was 11.43 cm (4.5 in.), and the nominal wall thickness was 0.76 cm(0.3 in.).

The short transition pieces gradually increased the inside diameterof the elbow from 7.06 to 7.24 cm (2.78 to 2.85 in.), which is less than theinside diameter of the connected pipes, 7.29 cm (2.87 in.). Measurements ofthe elbow cross section at the different locations showed a slightly eggshapedcross section, with the inside diameter varying from one end to the other.

All flanges were connected to heavy brackets, which were anchored tothe ground to limit the lateral and axial motion of the flanges.

Eighteen pressure transducers, shown by P1-P18 in Fig. 2, were usedto monitor the pressure-pulse propagation along the system. Up to threepressure transducers circumferentially distributed around the pipe were usedat one axial location to check the effects of the elbow on the axisymmetry ofthe flow in the pipes upstream and downstream from the elbow. Also, threepressure gauges, P11-P13, were used at the midsection of the elbow to recordany radial pressure distribution inside the elbow.

Twenty strain gauges, shown by SGI-SGzo in Fig. 2, were used at fouraxial locations in the first flexible pipe to monitor its response to the traveling

Page 13: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

13

pressure pulses. Similar to the straight-flexible-pipe tests, they were dis-tributed in groups of five at each axial location to check the uniformity ofstrains around the circumference of the pipe. The second flexible pipe wasnot instrumented with strain gauges.

III. DISCUSSION OF EXPERIMENTAL RESULTS

A. Straight-flexible-pipe Tests

The experimental results of the two straight-flexible-pipe tests FP-SP-101 and -102 are summarized in Fig. 3, which shows the peak pressuresalong the pipe system and their relation to the deformation of the flexiblepipe walls.

Pt P2 P3 P4PS P 7PP P9 PP

FP-SP-102 30

2200 - WALL DEFORMEDCONFIGURATION 10 '

1600 -FP-SP-01 -30

20

1400 10

1000

VIELD PRESSURE OF

600 o TEST FP-SP-101

+ TEST FP-SP-102

200-

0 20 40 60 60 00 0 2 40 60LDIGTH ALONG THICK-WALLED PIPE, U. LENGT ALONG FLEXIBLE

PIPE, I.

Fig. 3. Peak Pressure and Pipe-wall Deformed Shape for Straight-flexible-pipe Tests. Conversion factors: 1 psi = 6.895 kPa;

1 in. = 2.54 cm; 1 mil = 2.54 x 10-2 mm.

Plastic wall deformation at the beginning of the flexible test piperapidly reduces the pressure peak from about 13.8 MPa (2000 psi) in the thick-walled pipe to about 6.9 MPa (1000 psi) in only 3.81 cm (1.5 in.) of the flexiblepipe. The pressure peaks drop further as they propagate along the flexiblepipe to a value of about 3.8 MPa (550 psi), which is slightly higher than theyield pressure of the pipe of about 3.5 MPa (510 psi) in 45.7 cm (18 in.) of theflexible test pipe. The difference is due to the inertia of the pipe walls.

Beyond the region of plastic wall deformation the peak pressure remainsat the same level until the incident pulse hits the blind flange. A pressurepulse of larger magnitude reflects back to the pipe moving from right to left.

Page 14: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

14

This reflected pulse causes plastic wall deformation to occur in the

vicinity of the blind flange, reducing the pressure peaks of the reflected pulseto a value slightly higher than the yield pressure of the pipe in about 30 cm(12 in.). Thus, the middle part of the test pipe shows no plastic wall de-formation, and the level of the pressure peaks there remains constant at aslightly higher value than the yield pressure of the pipe.

Besides physically describing the phenomena, Fig. 3 also helps inevaluating and interpreting the records of the different pressure gauges. Forexample, the pressure peak at P1, the first gauge in the thick-walled pipe, isshown to differ between the two tests, and both are lower than expected. Inthe pulse-gun calibration tests, the pressure peak at the same location wasrecorded consistently at about 15.9 MPa (2300 psi). The same explosivecharge (3.65 g) used in the calibration tests was used in tests FP-SP-101

and -102. The fact that the pressure peaks at location P2 in test FP-SP-101and at location P3 in test FP-SP- 102 were higher than that at P1 also indicatesthat the pressure peak at P1 was on the low side. The pressure pulse at P1is to be used in the analysis as an input se '.rce to the ICEPEL model.

Another example is the pressure records at gauges P7 and P9, whichare shown to have peak pressures lower than the yield pressure of the pipeand also lower than the peak pressures at gauges P6 and P8. Intuitively, asexplained before, plastic pipe wall deformation cannot reduce the peak pres-sure of the traveling pulses below the yield pressure of the pipe.

Furthermore, the fact that the pipe wall has been deformed plasticallyat location P9, as shown by the deformed configuration of the pipe, indicatesthat the pressure peak at this location must have been above the yield pres-sure of the pipe. Thus, it can be concluded that both gauges P7 and P9, whichrecorded lower pressures were in error in both tests.

Table I summarizes the strain results for the straight-flexible-pipetests. The table indicates variations in the strain records at the same axiallocation. SRI attributed this variation to variations in pipe-wall thicknessesaround the circumference, which were measured before and after the testsand are also shown in Table I.

Although the records of tests FP-SP-101 almost indicate that higheststrains were recorded at locations of smallest thickness, and vice versa, therecords of test FP-SP- 102 was not consistent with that. This indicates thatthe variation in strains around the pipe circumference was not totally due topipe-wall-thickness variation, which was within 5%. Another source of suchvariations is the pipe bending resulting from imperfections in the test pipe,which was a commercial off-the-shelf pipe. Appendix A presents an analyticalstudy of the effect of thickness variations on strain predictions.

Page 15: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

15

TABLE I. Summary of Strain Resultsfor Straight-flexible-pipe Tests

Test FP-SP-101 Test FP-SP-102

Wall Dynamic Posttest Wall Dynamic PosttestStrain Thickness, Strain, Strain, Thickness, Strain, Strain,Gauge in. ain. a

SG1 0.064 1.18 1.07 0.062 1.14 1.09SG= 0.063 1.21 1.12 0.066 1.22 1.18SG 3 0.064 1.04 1.03 0.068 0.90 0.89SG4 0.065 0.97 0.90 0.065 1.23 1.14SGs 0.066 0.78 0.71 0.063 1.14 1.08SG6 0.065 0.20 0.15 0.062 0.33 0.27SG 7 0.063 0.43 0.38 0.068 0.45 0.42SGs 0.065 0.37 0.34 0.069 0.36 0.34SG, 0.066 0.32 0.29 0.068 0 41 0.36SG, 0 0.067 0.15 0.11 0.066 0.40 0.34SG,1 0.065 0.04-0.08 0.06 0.062 0.05-0.17 0.14SG 12 0.063 0.03-0.22 0.19 0.067 0.04-0.24 0.22SG1, 0.062 0.03-0.19 0.19 0.067 0.03-0.08 0.05SG 4 0.063 0.04-0.25 0.19 0.066 0.05-0.20 0.19SGS 0.065 0.04-0.05 0.02 0.063 0.03-0.06 0.03SGe 0.068 0.19 0.18 0.062 0.31 0.25SG, 7 0.065 0.37 0.37 0.069 0.44 0.39SG, 0.065 0.29 0.27 0.069 0.28 0.23SG1, 0.066 0.30 0.27 0.068 0.33 0.31SGzo 0.067 0.16 0.14 0.064 0.13 0.11

aConversion factor: I in = 2.54 cm.

The pressure-transducer mountingstrain variation around the circumference.

bosses may also contribute to theThe mounting bosses are likely

to stiffen the pipe walls in their vicinity. Test FP-SP-101 records showedthat, except for the first axial location, the strain records at gauges closestto thb mounting bosses were the lowest. However, test FP-SP-102 did notshow the same consistent trend.

B. Singie-elbow Loop Tests

The experimental results for three single-elbow loop tests, FP-E-101,-102, and -103, are summarized in Fig. 4, which shows the pressure peaksalong the system and the posttest deformed-pipe configuration for the twoflexible pipes. Similar to the straight-flexible-pipe tests, the plastic walldeformation at the beginning of the flexible pipe reduced the pressure peaksrapidly to less than half its value in the thick-walled pipe in only 3.81 cm(1.5 in.). The pressure peaks reached a level slightly higher than the yieldpressure in 45.7 cm (18 in.).

The pressure peaks are shown to remain at that level until it suffersa reduction of around 18% as it moves around the elbow. However, both testsFP-E-101 and -103 showed the pressure peaks to increase slightly in thesecond flexible pipe as the distance increased from the elbow. The reasoncould be the blind flange at the end of the second flexible pipe in test FP-E-10 3.But test FP-E-101, in which the second flexible pipe ended with a simple openend, also showed the same trend. In the elastic test, FP-E-102, all recordsin the second flexible pipe were lost.

Page 16: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

P2 P2 P P5 +P6 P7 PBPIO" V 1

1 1 1 U I I i I U

THICK-WALLED PIPE +

I TI

0

0

TEST FP-E-101 (G-Eei END)TEST FP-E-103 (CLOSED END)TEST FP-E-102 (ELASTIC)

0 .

r A

FIRST FLEXIBLE PIPE

FP-E-103

I-'

w1

30 30

20

10

] 2t FP-E-101

' 10

I %

0 + YIELD PRESSURE OFFLEXIBLE PIPES

-Q+

0 0 0 0

I I " " I . II ....I jl p i 1 I I

0 a 20 30 40 50 60 70 80 90 100 110LENGTH ALONG THICK-WALLED PIPE, in.

00

20

10

020

10

0

-T

T

0 10 20 30 40 50 60 ELBOWLENGTH ALONG 1st FLEXIBLE PIPE, In.

P14-P16 PI7-PI8

I I I I

SECOND FLEXIBLE PIPE

FP-E-103-- '

-0- - --

FPE-0

o 10 20 30 40 50LENGTH ALONG 2rd FLEXIBLE PIPE

60

Fig. 4. Peak Pressure and Pipe-wall Deformed Shape for Single-elbow Loop Tests. Conversion

factors: 1 psi = 6.895 kPa; 1 in. = 2.54 cm; 1 mil = 2.54 x 10-2 mm.

P1

20001-

16001-0

"

S1200

A.

800

0

+"

4001-

0

0

)

Page 17: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

17

In test FP-E-103, the incident pressure pulse hit the blind flange andreflected a pressure pul a of larger peaks, which caused plastic wall de-formation to occur in the vicinity of the blind flange. This, in turn, reducedthe pressure peaks to a level slightly higher than the yield pressure of thepipe. The only dynamic-strain or pressure measurements taken in the secondflexible pipe were pressures near the elbow.

The posttest measurements of the deformed configuration of the twoflexible pipes for tests FP-E-101 and -103 showthatplastic wall deformationoccurred at the beginning of the first flexible pipe, around the elbow, andnear the blind flange for ;est FP--E-103. For test FP-E-101, no measurablechange in the dimensions of the second flexible pipe was recorded.

The bulges in the two flexible-pipe ends near the elbow may suggesta reflected pressure pulse from the elbow due to the heavy (rigid) wall of theelbow. However, such measurements are not reliable enough to make such aconclusion, particularly because the pipes were commercial pipes with im-perfections in their dimensions, and because insufficient dynamic-strainmeasurements were taken in the two flexible pipes near the elbow.

Comparing the records of the different gauges in each test, one canconclude that gauge P3 recorded higher pressures in tests FP-E-101 and -103.Gauges P5-P7 in tests FP-E-101 are believed to be recording slightly lowerpressures, in'particular, gauge P6, which is recording pressure peaks evenlower than the yield pressure of the pipe. Also, gauges P4 and P6 in theelastic test FP-E- 102 are bi lieved to record lower pressures.

As ir the straight-flexible-pipe .ests, using the same explosive charge(3.65 g) in tests FP-E-101 and -103 as that used in the pulse-gun calibrationtests produced lower pressure peaks at gauge P1, especially in test FP-E-101.However, the posttest deformed configuration of the first flexible pipe is com-patible with the low pressure peaks, when compared with the posttest deformedconfiguration of the first flexible pipe of test FP-E-103. In test FP-E- 103,the deformed pipe configuration slows the largest change in diameter 2.03 cm(0.8 in.) from the flange; in test FP-E-101, the largest change in diameter wasmeasured 3.81 cm (1.5 in.) from the flange. In other words, the difference indeformation of the first flexible pipe, shown in Fig. 4, cannot be relied on toindicate that the pressure peak in the thick-walled pipe was in fact low intest FP-E- 101.

The dynamic-strain measurement at one axial location showed an evenwider scatter than that of the straight-flexible-pipe tests. Again, this cannotbe totally attributed to variations in the wall thickness around the circumferenceof the pipe. Bending of the pipes is more likely in the single-elbow loop testsbecause of the changes in the direction of the flow due to the elbow.

Page 18: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

18

IV. ICEPEL ANALYTICAL MODELS

Since only pressure histories of the form P(t) can be used as an inputto an ICEPEL model of a piping system, the pressure history recorded bygauge P1 is used as an input pulse to the pipe system downstream from thegauge. The duration of the pressure history as recorded by gauge P1 is 3 ms,and a pressure pulse requires more than 3 ms to travel from gauge P1 to theentrance to the thin-walled flexible nickel-200 pipe and back to gauge P1. Thepressure record at P1 therefore does not include any interactions between the

incident pulse and any possible reflections from the flexible pipe. Hence, the

pressure pulse at P1 can be safely used as an input to the analytical model.

Thus, Fig. 5 shows that the ICEPEL model of the straight-flexible-pipetests considers only 228.6 cm (90 in.) of the thick-walled pipe directly flangedto 152.4 cm (60 in.) of flexible test pipe, which ends with a rigid dead end.Both the thick-walled pipe and the test pipes are divided into equal-size zonesof 1.82-cm (0.72-in.) radial zone size and 2.54-cm (1-in.) axial zone size.

56 520

THICK -lAll PIPE S ', - SG, 0S6-010 0$611 0SG

PI P2 P3 P4 PS P6 PT PS P9 PV

226.6 cm (90a., 90 ZONES) 152.4 c 160 is.. 60 ZONES -

Fig. 5. ICEPEL Model of Straight-flexible-pipe Tests

The walls of the thick-walled stainless steel pipe are considered inthe model as made of nickel-200, the same material as the flexible test pipe,but with a 1-cm-thick wall, because the material properties of thick-walledstainless steel pipes were not measured by SRI. Since elastic-pipe-wallresponse does not significantly alter the shape or magnitude of travelingpressure pulses, the substitution of the thick-walled stainless steel pipe bya thick-walled nickel-200 pipe is not expected to affect the results in the regionof interest, the flexible nickel-200 pipe system, as long as the response of thethick-walled pipe remains elastic in the analysis and in the experiment. Thewalls of the flexible test pipe are 0.165 cm (0.065 in.). The heavy blind flangeat the end of the flexible pipe is further represented by a fixed boundary con-dition for the pipe walls; i.e., neither translation nor rotation is permittedat the last wall nodal point.

The system is considered full of stagnant water at the moment ofapplication of the input pressure pulse.

Similarly, for the single-elbow loop tests, the ICEPEL model, shownin Fig. 6, consists of three pipes divided into uniform zones of the same sizeas those of the straight-flexible-pipe test model. The thick-walled elbow isrepresented by a rigid elbow connecting the two flexible pipes in series.

Page 19: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

In

Rigid Pipe

0 O

N1Coc6

Flexible Pipe 11 11 1 11 1, 1t 11 1 11 11 r1 11 1 1l l tl .l 1 11 1 1tj11 l II g 1in i1luuuuuuuuuuu1I1111111uiuiiuuuhhuu ui l111111111

P1 Input Pulse P2

228.6 cm (90 in. 90 Zones)

P3 P4 P59 9P6 P7 P8-10

152.4 cm (60 in.60 Zones)

Rigid El

P14-16

PI7-18

C

c

.1

Rigid Dead End

Fig. 6. ICEPEL Model of Single-elbow Loop Tests

~0

Ibow

eVnN

NO~

0

O

in

v

W

0.

I1

I

Page 20: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

The elbow itself has a radius of curvature of 11.43 cm (4.5 in.) and isdivided into four radial zones and five tangential zones. The rigidity of theelbow is represented by fixing the fictitious nodes between the two flexiblepipes.

For tests FP-E-102 and -103, the end of the second flexible pipe ismodeled arj a rigid dead end, allowing neither translation nor rotation at thelast wall node. For test FP-E-101, the end of the second flexible pipe is con-sidered open to zero pressure at all times, representing the open-end boundarycondition there.

The walls of the thick-walled stainless steel pipe and the flexiblenickel-20 pipes are modeled in exactly the same way as in the straight-flexible-pipe test model described above. Again, the system is consideredfull of stagnant water at the moment of input-pulse application.

Page 21: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

21

V. PIPE-WALL MATERIAL PROPERTIES

Stress-strain properties of nickel-ZOO were measured by SRI onspecimens cut from a scrap section of the nickel-Z00 pipes. The specimenswere flattened, then annealed i.i exactly the same way a. the test pipes.

Stress-strain properties were measured at two strain rates to deter-mine if nickel-Z00 is strain-rate-dependent. The results are shown in Fig. 7at two different strain rates. No significant effect was found for a three-order-

of-magnitude increase in strain rate.200 - Hence, SRI concluded that nickel-Z00

-2 0- is nearly free of strain-rate effects.

1502.3 x102s-- More tests at higher strain rates would

.-- ' .7 k s-1 have been more desirable to closelydefine the material properties at test

100 -conditions.

0 SPECIFIC VALUES USED IN Since the actual strain rate in50 - ICEPEL ~ the pipe tests is about three orders of

magnitudes higher than the highest

0 0.5 1.0 1.5 2.0 2.5 3.0 strain rate of the material-property

STRAIN,% tests, the stress-strain properties atthe higher strain rate is considered

Fig. 7. Stress-Strain Curves for Nickel-200 to approximate those of the test pipes.

In the ICEPEL code, stress-strain relationships are approximated bya piecewise stress-strain curve. Attempts to closely approximate such abehavior with a bilinear relationship usually end with an artificially higheryield stress than the true yield stress of the material in order to approximatethe plastic part of the curve. Such an approximation is acceptable if the strainsare known to be well in the plastic region.

However, in a piping system, the magnitude of the pressure peaks trans-mitted beyond the region of plastic wall deformation depends on the yield pres-sure of the pipe. A higher yield stress for the pipe-wall material permitstransmission of higher pressure peaks.

Consequently, the pressure pulses that result from the interaction ofthe transmitted pressure pulse with piping components or with flow-areachanges in the system, as well as the plastic wall deformation resulting fromthese pulses, are bound to be overestimated as a result of the artificiallyhigher yield stress for the wall material.

This type of result was observed on a preliminary model of the straight-flexible-pipe tests in which a bilinear stress-strain relationship was used.Higher pressure peaks were transmitted beyond the region of plastic wall

Page 22: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

22

deformation. This resulted in higher pressures reflecting from the blindflange and higher strains in the flange vicinity. Reducing the yield stress ina bilinear relationship or using a multilinear stress-strain relationship reducedthe transmitted pressure peaks and, hence, reduced the strain at the right endof the pipe. The details of this preliminary study are presented in Appendix B.

Therefore, a four-segment piecewise linear stress-strain relationshipis used to approximate the stress-strain properties at the higher strain rate.This relation is shown in Fig. 7 by the circles and is listed in Table U.

TABLE II. Stress-StrainValues of Nickel-200 Usedin ICEPEL Calculations

Stress, MPa Strain, cm/cm

76 0.000393

95 0.00127

118.6 0.0058

384 0.1

VI. COMPARISON OF ANALYTICAL AND EXPERIMENTAL RESULTS

A. Straight-flexible-pipe Tests

Most of the figures of this section comparing the analytical and experi-mental results consist of two parts: part (a) for test FP-SP-101, and part (b)for test FP-SP-102. The solid line represents the experimental results andthe dashed line the analytical results from ICEPEL.

Figure 8 shows the input pressure pulses for the ICEPEL model asrecorded by gauge P1 for both tests. The input pressure pulse for test FP-SP-101 is seen to have a lesser magnitude and smaller duration than that oftest FP-SP-102, even though the same calibrated charge of 3.65 g was usedin both tests, as well as in all the pulse-gun calibration tests, where it con-sistently produced a pressure peak of about 15.8 MPa (2300 psi) at gauge P1.

Figures 9 and 10 compare the experimental and calculated pressurehistories at locations P2 and P3, respectively, of the thick-walled pipe. Ascan be seen, there is good agreement in the pulse shape and arrival time.However, the calculated peak pressure at the two locations are shown to beless than the experimental ones, particularly at location P3 of test FP-SP-102.

Page 23: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

23

This is to be expected because of the inherent feature of the implicit finite-difference methods in smearing off sharp pressure peaks such as those atP2 and P3. Decreasing the hydrodynamic time step in the calculations resultsin better resolution of sharp pressure peaks. Another reason for this differ-ence is the high experimental pressure peak at location P3 which is even higherthan the pressure peaks at location P1 and P2 upstream from P3. However,because of the consistently higher peak pressure obtained at P1 in all the pulse-calibration tests, one can argue that the pressures at locations P1 and P2 mayhave been low.

TEST FP-SP-10212.5

10.0

7.5

5.0 . l .' TEST FP -SP-101

2.5'

n0.5 1.0 1.5 2.0

TIME, ms

a .5 3. 4.5 .o t. STime, s

Fig. 8

Input Pressure Pulses forTests FP-SP-101 and -102

2.5 3.0 3.5

15.0

125

10 .0

*1

9A

75

0.0a o l3 3.0 45 160 T5

TimesmN

Fig. 9. Comparison of Analytical and Experimental Pressure Histories at Location P2in Thick-walled Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

2c

5.0

12.5

10.0

7.5

5.04

2.5:

0n

(a)

ICEPEL, R I-'" Ra 2

ICEPEL

- kRI

9.0

-1 1 4 10 -s-

)

.-

Ie

v

5.0

v EMU .

Page 24: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

24

17.5

15.015.0

12.5125

DI0.0

10.0-

5.0 0

TCEPEL

ICEPE L, Run I

2.5-'- Run 2 2.5 -

0 1.5 3.0 4.5 6.0 7.5 9.0 070.7350 45 60 75 9.0Time, ms Time, ms

Fig. 10. Comparison of Analytical and Experimental Pressure Histories at Location P3of Thick-walled Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

The figures also indicate the occurrence of cavitation at location P2,a result of the right-to-left rarefaction wave reflecting from the flexible pipe.Cavitation is indicated in the calculation by the zero cutoff pressure; i.e., pres-sures in the calculation are not allowed to go below zero. In the experiment,cavitation is indicated also by the zero record of the pressure gauge. The cal-culation also shows the last peak as the reflected pressure pulse from the blindflange at the end of the flexible pipe. The experimental records were cut offbefore the arrival of the reflected pulse.

Figures 11 and 12 compare the calculated and measured pressure his-tories at locations P4 and P5. The plastic wall deformation at the beginningof the flexible pipe is shown to attenuate the pressure peaks rapidly to about6 MPa at location P4, 3.81 cm from the flange, and further to about 5 MPa atP5, 15.24 cm from the flange. The pulse shape is also wider than the appliedpulse, indicating the dispersion of the pressure pulse caused by the plasticwall deformation.

Again, excellent agreement is indicated between the calculations andthe measurements insofar as the incident pulse is concerned. The reflectedpulse from the blind flange, however, is consistently higher in the calculationthan in the experiments. The reason for this is the modeling of the blindflange as an absolute rigid dead end in the analysis. Thus, the analysis ismore conservative than the experiment in the sense that the analysis does notallow any motion of the pipe. Experimentally, although the flanges were limitedin their motion by the heavy brackets, which were anchored to the ground, stillsome of the incident pulse energy was consumed in the axial motion of the pipeas the pulse hit the flange.

Page 25: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

25

0 1.5 3.0 4.5 6.0 7.5 9.0Timems

7.0

6.0

7

6

5

3

2-

-

30 45 60 75 90lime, as

Fig. 11. Comparison of Analytical and Experimental Pressure Histories at Location P4of Flexible Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

6

1d.

0 1.5 3.0 4.5 ETime, as

60

5.0

40

30

20

1.0

00.0 7.5 9.0 O a is 30 45

Tme, mt6o T.5 .o

Fig. 12. ComparIson of Analytical and Experimental Pressure Histories at Location P5of Flexible Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

Figures 13-16 compare the calculated and measured pressure historiesat locations P6-P9 in the middle section of the flexible pipe. The plastic walldeformation of the pipe is shown to further attenuate the incident pressure pulsepeaks until this pulse reaches a level slightly higher than the yield pressure of

(a)

' ICEPEL. Runt / - ICEPEL Run2

SR .

SRI

d. 40

:303.0

20

0

00I14

(b)

ICEPEL

SRI-'

ICEPEL, Run 2

SRIICEPEL, Ruast,

ICEPEL

- i

___l 1 1 1 1

Iq

00 1.5C

I

Page 26: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

26

the pipe (about 3.5 MPa). Thus, the transmitted pressure peal, s beyond theregion of plastic wall deformation is about 4 MPa and is in good agreement withthe experimental measurements at gauge P8.

0 1.5 3.0 4.5 6Time, s

6

5.-

a

j3-2

0

6.0

5.0

4.0

a

3.0L

29 0 .-

0.0-9.0 0.0

Fig. 13. Comparison of Analytical and Experimental Pressure Histories at Location P6of Flexible Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

0 I.5 3.0 4 1T le~s

6.0 7.5

4

3

2T

II-

U,

9.0 0

. -.. I

sm-1

I 5 30 4.5Trme, s

6.0 7.5 I.0

Fig. 14. ComparIson of Analytical and Experimental Prmure Histories at Location P7of Flexible Pipe. (a) Tat FP-4P-101 and (b) Tat P4P-6102.

D 7.5

(")

ICEPEL, Run I

2

~SRI

--- rI-V

(b)

., /-ICEPEL

-RI

j I

I' 30 45T s , s

60 75 90

(8)

ICEPEIjRiI

1-."

S'',

6

4

a

s

0

PE9-- A-

Page 27: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

(h

4 1 '. ICEPEL, Runt1

2

3 '

SRI2

0-0 I5 3.0 4.5

Time, ms60 75

6.0

50

40-

i30

20

10

0090 0.0 I5 30 45 60 75

Time, as

Fig. 15. Comparison of Analytical and Experimental Pressure Histories at Location P8of Flexible Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

0 1.5 3.0 4.5Time , "s

60

50

40ohF

30

20

10

J 0 -60 7.5 90 00 Is so 43

lurng ms

Fig. 16. Compardon of Analytical and Experimental Pressure Histories at Location P9of Flexible Pipe. (a) Test FP-SP-1O1; and (b) Test FP-Sn102.

As expected from the discussions of the experimental results, the cal-culated pressures are higher than the measured ones at gauges P7 and P9 ofFigs. 14 and 16, respectively. The reason for this is that both gauges arebelieved to be in error when recording lower pressures.

Again, the reflected pressure pulse is consistently higher in the cal-culation than in the experiment. At gauge P9, the calculation briefly shows

6

5

8

a

27

(b)

ICEPEL

-SRI

IY

-

90

6

5.

4,

2

0

(i)

ICEPEL, Run I

SRI

(b)

ICEPEL

SI 1

60 15 to__l _ I 1 m

Page 28: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

28

the incident pressure pulse indicated by the first plateau in Fig. 16, beforethe arrival of the reflected pressure pulse from the blind flange.

In the vicinity of the blind flange, Figs. 17 and 18 compare the calculatedand measured pressure histories at gauges P10 and P11, respectively. Exceptfor the calculated pressures being slightly higher than the measured ones be-cause of the conservative modeling of the blind flange in the analysis, theagreement in pulse shape and arrival time is very good.

6

5

4

8

"3

2

I -

01.5 3.0 4.5m 6.0 7.5 9.0

60

5.0

4.0

" 30

20

'0

(a)

' ICEPEL, Run 1( 2

SRI '.'

I ' K

00 IS 30 45Time, as

60 75 90

Fig. 17. Comparison of Analytical and Experimental Pressure Histories at Location P10

of Flexible Pipe. (a) Test FP-SP-101; and (b) Test FP-SP-102.

1. 30 4.5TIm' ms

6.0 7.5

E

4

2

53

090

ICEPEL

.1>1

0 1.5 3.0 4.5 6.0Time ,as

Fig. 18. Comparison of Analytical and Experimental Pressure Histories at location P11at Blind Flagge. (a) Test FPP-'101 and (b) Test FP-SP-102.

0n0

(b)ICEPEL

SRI

6

5,

j3

AL

(a)

' " ICEPEL. Run I

SRI

I-N

7.5 9o

V V

I

0

Page 29: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

29

Figures 19 and 20 compare the calculated and measured circumferentialstrain histories at the four axial locations of the flexible test pipe. As can beseen in Fig. 19, the analytical strains at the first axial strain location,gauges SG1 -SG 5 (3.81 cm from the flange with the thick-walled pipe), matchthe lower bound of the experimental strain scatter for test FP-SP-102. Butthe analytical strains are lower than the experimental strain scatter for

1.50

1.25

100

.075

0 50

0.25,

0

1 50

". 1.25

ICEPEL, Run 2 100

0.75ICEPEL, RunI

0 50

0 25

0 006.0 7.5 9.0 00 15 3o 45

Time, ms

-SRI

----- ICEPEL

60 75 90

Fig. 19. Comparison of Analytical and Experimental Strain Histories at Lo-cation SG1-SG5. (a) Test FP-SP-101; and (b) Test FP-SP-102.

0 1.5 3.0 4.5Time, ms

60 7.5

06

I-

In

04

0.3 }

0.2

0.1

090 0 1.5 5.0 4.5

Time, mo6.0 7.5 90

FIg. 20. ComparIson of Analytical and Experimental Strain Histories at Lo-

cation 8G6-SG*. (a) Test FP-6P101; and (b) Test FMPS102.

CL,)(a) n

1.5 3.0 4.5Time, ms

0

0.6

Ob

04

10.3

02

0.1

0.

c")

SRI

ICEPEL , Run 2

----...-- --- nun

rot - SRI----- ICEPEL

E

w

Arm w

- . - - - - . - - - -

CI

Page 30: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

30

test FP-SP-101. At the second axial strain location, gauges SG6 -SGio(15.24 cm from the flange with the thick-walled pipe), the analytical strainsfall within the experimental strain scatter but close to the lower bound, ascan be seen in Fig. 20. The reason for this is believed to be the relativelylow pressure peak recorded at gauge P1, which is used as an input to theanalytical model. Both the shape and arrival time are in good agreement.

At the other end of the pipe, near the blind flange, Figs. 21 and 22show the analytical strains to fall within the experimental strain scatter, but

on the contrary, closer to the upper bound. This is 'J be expected as a con-

sequence of the conservative modeling of the blind flange in the analysis,

0 i5 30 ' 45Time, ms

60 75 9

04

0.3

CLc

0.2-

1.5 3.0 4.5Time, ms

0

0p 0 60 75 90

Fig. 21. Comparison of Analytical and Experimental Strain Histories at Lo-cation SG11-SG15. (a) Test FP-SP-101; and (b) Test FP-SP-102.

04

C03{

02

01

J 016.0 7.5 90 0 1.5 3.0 4.5

Times60 75 9.0

Fig. 22. Compaison of Analytical and Experimental Strain Histories at Lo-cation SG 16-SG 2 0. (a) Test FP-SP-101; and (b) Test FP-SP-102.

0.4

0.3

0 2

01

0

(a )

SRI

ICEPEL,Run 2

" wRun \

(b)

SRI------- ICEPEL

-7

-

0.5 r

04

0.3

02

0.1I,

(a) SRI

ICEPEL.,RUN IRUN 2

-_ I

(b)

- SRI

---- ICEPEL

I-1

0

.ni l

0 3.0 4.5Tietms

Page 31: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

31

resulting in higher reflected pressure pulses, which in turn led to higherstrains in this vicinity. The plastic strain at this end of the pipe is caused bythe reflected pulse, not the incident one.

All the comparisons of test FP-SP-101 are similar to those oftest FP-SP-102, except for the analytical strains for test FP-SP-101 beinglower than the experimental strains only at the first axial strain location.

The reason for this is believed to be the relatively lower and narrower pres-sure peak at gauge P1 (shown in Fig. 8). Therefore the effect of increasingthe peak input pressure on the ICEPEL calculation is examined by only in-creasing the peak portion of the pulse at P1 by 25%. The results of thecomparison of this run with the experimental results of test FP-SP-101 areshown by the chain-dashed line of part (a) of Figs. 9-22.

Inside the thick-walled pipe, at locations P2 and P3 of Figs. 9 and 10,better agreement with the experimental measurements was obtained. However,

the calculated peaks remained below the experimental ones. Also, the effectof the rarefaction wave reflecting from the flexible pipe on the pressure historyat location P3 was in better agreement with the experiment.

Insignificant effects were obtained on the analytical pressure historiesinside the flexible pipe. Also, the reflected pressure pulse from the blindflange was unaffected, indicating the dependence of the transmitted pressurepeaks beyond the region of plastic wall deformation on the yield pressure ofthe pipe.

The analytical strains were raised by about 45% at the first axiallocation, 3.81 cm into the flexible pipe, thus falling within the experimentaldata as shown by the chain-dashed line of Fig. 23. At the other axial locations,the strains were slightly higher, but remained within the experimental scatter,as can be seen in Figs. 19-22.

5 0

12.5 1

5.0 E-103

s...

2.5

TEST E 11lW"

00 0 .5 10 5.5 2.0 2.5 3D

Fig. 23. Input Preasute Pulses for AnalyticalModels of TestsFP-E-101 and -103

B. Single-elbow Loop Tests

The two plastic single-elbow looptests, FP-E-101 and -103, are analyzed bythe ICEPEL code and the results are comparedwith the experimental results. Part (a) ofeach comparison figures is for test FP-E-101,in which the end of the second flexible pipewas a simple open end. Part (b) is fortest FP-E- 10 3, in which the second flexiblepipe ended with a blind flange.

Figure 23 shows the input pulses forthe analytical models of the two tests, asrecorded experimentally by gauge P1. Thepulse for test FP-E-101 is much weaker than

Page 32: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

32

that of test FP-E- 103, even though the same explosive charge of 3.65 g wasused in both tests. The same charge consistently produced pressure peaks ofthe order of 15.8 MPa at location P1 in all the pulse-gun calibration tests.

Figures 24 and 25 compare the analytical and experimental pressurehistories at locations P2 and P3 inside the thick-walled pipe. Similar to thestraight-flexible-pipe tests, very good agreement is shown with respect tothe pulse shape, pulse arrival time, and prediction of cavitation at location P2.Also, the analytical pressure peaks are less than the experimental ones,particularly at location P3. However, the pressure peak at location P3 ishigher than that at P1 and P2 upstream from P3 for the same reasons discussedin the straight-flexible-pipe tests.

In test FP-E-103, the reflected pressure pulse from the blind flangeat the end of the second flexible pipe is shown by the analysis. No experimentalrecords were obtained at P2 and P3 beyond 3 ms. Also, the analytical resultsdemonstrate the smearing off of the sharp pressure peaks by the implicitfinite- difference methods.

Figures 26 and 27 compare the analytical and experimental pressurehistories at locations P4 and P5 at the beginning of the first flexible pipe.Plastic pipe wall deformation is shown to reduce the pressure peak rapidly toabout half its value at P3 in only 3.81 cm (1.5 in.) and to further reduce thepressure peak at location P5. The analytical pressures are slightly higherthan the experimental pressures at gauge P4, especially for the tail part ofthe incident pulse. The noise in the experimental data at gauge P4 may beattributed to the proximity of the gauge to the heavy flange with thick-walledpipe. At location P5, however, the agreement between the experiment andanalysis is better.

12.5

17.5

10.0-15.0- SRI - Experiment

0

i 7.5 12.5

5.0 SRI 7.5ICEPEL, RUN I

ICEPL RN 25.0-2.5 -ICEPEL ,RUN 2 5ICEPEL-Analysis

2.5

0 0/0 1.5 3.0 4.5 6.0 0 1.5 3.0 4.5 6.0 7.5 9.0 10.5

Times Time,ms

Fig. 24. Comparison of Analytical and Experimental Pressure Histories at Location P2 of Thick-walled Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

Page 33: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

15.)(a)

12.5

.SRI 17-5 -

00SO1 5SRI - Experiment

15.0I

7. 12.5

ICEPEL, RUNI1a. It.10.0-

5D - ICEPELRUN2 7.5

5.0- ICEPEL - Analysis2.5 -

2.5-%%

01.5 3.0 4.5 6.0 0 1.5 3.0 4.5 6.0 7.5 9.0 10.5Time, ms Time,ms

Fig. 25. Comparison of Analytical and Experimental Pressure Histories at Location P3 of Thick-walled Pipe of Single-elbow Loop Tests. (a) Test FP-E-1)1; and (b) Test FP-E-103.

6

I7 -5I6

3 SRI .4 -ICEPEL-Anlysis

\SRI-Experiment2 -,

ICEPEL, RUN 12

l ; -

ICEPEL , RUN 2

o O

0 -'-0 - - - - --

0 1.5 3.0 4.5 6.0 7.5 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0Time, mas Time, mas

Fig. 26. Comparison of Analytical and Experimental Pressure Histories at Location P4 of First Flex-ible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP--103.

33

(b)

Page 34: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

65

4

a3

2z

4.5 6.0 7.5 1.5 3.0 4.5 6.0

Time, ms7.5 9.0 10.5 12.0

Fig. 27. Comparison of Analytical and Experimental Pressure Histories at Location P5 of First Flex-

ible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

Again, for test FP-E- 103, the reflected pressure pulse from the blindflange at the end of the second flexible pipe is slightly higher in the analysisthan in the experiment because of the conservative modeling of the blind flangein the analysis.

Figures 28-30 compare the analytical and experimental pressurehistories at locations P6, P7, and P8-PlO of the first flexible pipe. Plasticwall deformation has reduced the pressure peaks to a value of about 4 MPa,which is slightly higher than the yield pressure of the pipe (3.5 MPa). Goodagreement of all aspects of the pressure pulse is shown.

0 1.5 3.0 4.5Time, ms

6

4a2~

21

n6.0 7-5 0 1.5 3.0 4.5 6.0

Time,ms

Fig. 28. Comparison of Analytical and Experimental Pressure Histories at Location P6 of First Flex-ible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

34

(a)

ICEPEL, RUN I- ICEPEL, RUN 2

SRI

0l I

.a-

a-

rb)

-

ICEPEL- Analysis

3 - i\SRl- Experiment

/ -

I II

n0 1.5 3.0

Time ,o

0a-

a.

5(a)

4SRI

3

ICEPEL , RUN I

ICEPEL , RUN 2

- - ---

(b)

I~, CEPEL -Analysis

I'- SRI -Experiment

t

7.5 9.0 10.5 12.0

7

1

4

5}

i

.. V

Page 35: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

0 1.5 3.0 4Time, ms

6

5

5

4

d3

X2

.5 6.0 7.5 1.5 3.0 4.5 6.0Time,ms

7.5 9.0 10.5 12.0

Fig. 29. Comparison of Analytical and Experimental Pressure Histories at Location P7 of First Flex-ible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

5

4

03"

e

a.2

II

03.0 1.5 3.0mTlme,mas

7

0.

a-

4.5 6.0 1.5 3.0 4.5 6.0 7.5Time, ms

Fig. 30. Comparison of Analytical and Experimental Pressure Histories at Locations P8-P10 of First Flex-ible Pipe of Single-elbow Loop Tests. (a) Test FD'-E-101; and (b) Test FP-E-103.

As expected, at gauge P6, the analytical pressures are slightly higherthan the experimental pressures because P6 is believed to have been recordinglower pressures when comparing its records with the yield pressure of thopipe and with the pressure peaks at locations P7 and P8-PLO downstreamfrom it.

4

2

35

(a)

SRI

CEPEL, RUN 2

ICEPEL, RUN 2

_ I I 1

(b)

- oICEPEL Analysis

SRI-Experimen

I' /-%-%I

1 g1 I

1I I

(a)

ICEPELRUN 2

SRI ICEPEL,RUN I

- S

(b)

P8---------- "" P 9 SRI - Experiment

- - ICEPEL -Analysis

4 -

2

-

0 I I I I \;1lF

9.0 10.5 12A

0. .

_TI.

i

0J

-1

6

S

|

Page 36: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

36

Figure 30 indicates that the experimental records of gauges P8-PlOshowed no variation of pressure around the circumference of the pipe. Thisconfirms the axisymmetry of the flow in the pipe upstream from the elbow, anassumption used in the ICEPEL hydrodynamic coupling of the pipe and elbowmodels.

Figures 31 and 32 compare the analytical and experimental pressurehistories downstream from the elbow, at gauges P14-P16 and P17-P18. Again,the experimental records there affirm the axisymmetry of the flow in the pipedownstream from the elbow, showing no effect of the elbow. At both locations,the analysis has consistently overestimated the pressures. The reason isthat experimentally the elbow attenuated the pressure peaks by as much as18%, while the analysis did not show that much attenuation.

In fact, in test FP-E-103, the analysis showed no drop in peak pres-sures in its absolute sense. However, a careful investigation of the analyticalpressure histories before and after the elbow reveals some kind of loss insidethe elbow. Figure 30b shows that the pressure histories before the elbow havean almost flat pressure peak of about 4 MPa that lasted for about 0.75 ms.Figure 31b shows that the pressure history after the elbow rose at the samerate as that at locations P8-P10, before the elbow, until a pressure of about

3.5 MPa was reached; then the pressure continued to increase but at a reducedrate until it reached a peak of 4 MPa, which lasted only for a brief time com-pared with the peak time before the elbow.

In test FP-E-101, the comparison between the analytical pressurehistories before and after the elbow shows a drop in the peak pressure from 4to 3.75 MPa, a loss of about 6.75% compared to an 18% drop experimentally.

5(a) (b)

7-

4 --- -- PI4

6 - "-----------P15} SRI-ExperimentICEPEL,RUN 2 ICEPEL,RUN I -

5 -- - ICEPEL- Analysis

0 - S R I aI4

I -

0 1 0

0 0

1.5 3.0 4.5 6.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0Time, ms Time, ms

Fig. 31. Comparison of Analytical and Experimental Pressure Histories at Locations P14-P16 of Second

Flexible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

Page 37: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

37

5 6(a) (b)

54

ICEPEL, RUN 2ICEPEL, ICEPELRUNI 4 -

* -SRI

12 .'

0 01.5 3.0 4.5 6.0 1.5 3.0 4.5 6.0 7.5 9.0 IG5 12.0Time,ms Time, ms

Fig. 32. Comparison Fi Analytical and Experimental Pressure Histories at Locations P17 and P18 of SecondFlexible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

However, the experimental records of Figs. 31 and 32 show higher peaks atlocations P17 and P18 further away from the elbow, even though the pipe endwas open in this test. The experimental drop is only 10.8% if pressure peaksbefore the elbow are compared with those at locations P17 and P18.

As far as the pressure-peak attenuation along the elbow is concerned,the difference in the analytical results of tests FP-E-101 and -103 can onlybe attributed to the different boundary conditions of the second flexible pipe,being open in FP-E-101 and closed in FP-E-103.

Another source of the experimental pressure-peak attenuation along theelbow is the geometry of the elbow, which had a slight ovality in section. Also,the elbow had a nominal inside diameter of 7.06 cm and was connected toshore transition pieces that increased the diameter to 7.24 cm, which is lessthan the inside diameter (7.29 cm) of the connected pipes. This geometrycannot be included in the analytical model.

In the elastic test FP-E-102, all records in the second pipe were lost.Thus, no conclusion could be made about pressure-peak attenuation along theelbow in elastic systems.

Inside the elbow, the analysis showed that the pressures near the outerwalls of the elbow are higher than the pressures near the inner walls, whereasthe experimental data of tests FP-E-101 and -103 showed no special trend;i.e., there was no significant difference in the pressure inside the elbow.Only in the elastic test FP-E- 102, the experimental data showed higher pres-sures near the outer walls of the elbow than those near the inner walls, agreeingwith the analysis. But all pressure records downstream from the elbow werelost in this test.

Page 38: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

38

Figures 33 and 34 compare the analytical and experimental strainhistories at the beginning of the first flexible pipe, locations SG1 -SG 5 andSG 6-SGIO. For test FP-E-103, the analytical strains are within the ratherwide scatter of the experimental strains. For test FP-E- 101, the analyticalstrains at these two locations are well below the experimental strain scatter.The reason is believed to be the rather weak input pulse shown in Fig. 23.

1.50

i.251-

0 1.5 3.0 4Time, ms

9r 0.'.VV

1.75-

1.50

1.25OnC.r

a4n

0.50

0.25

(a)

SRI

ICEPEL,RUN 2

ZICEPEL, RUN I

1 1I1I

.5 6.0 7.5 0 1.5 3.0 4.5- Time, ms

Fig. 33. Comparison of Analytical and Experimental Strain Histories at Location SG1 -SG5 of FirstFlexible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

(a)

Solid Line - SR

ICEPEL,RUN 2

t,

"

rICEPE

L ,RUN I

1.5 3.0 4.5Time , ms

6.0 7.5 9.0

0.6

0.5

0.4

I$

~0.3

0.2

0.

Uw0I.3.0 4.5 6D

Time ,Ias

Fig. 34. Comparison of Analytical and Experimental Strain Histories at Location SG5-5G 0o of FirstFlexible Pipe of Single-elbow Loop Tests. (a) Test FP-4-101; and (b) Test FPE-103.

40C.W

u.

C.O

0

0.75

0.50

0.25

- SRI Experiment(SGI-SGS)- --- ICEPEL - Analytical

(b)

06.0 7.5

SRI EupeIiment (S66- SG10)ICEPEL -Analytical

Pal

0.4}-

J2.1

0O0 7.5 8.

A 1 11

K

rAW26M - - - Ir

1.00

0.T5

v

.1

I

Page 39: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

39

Figures 35 and 36 compare the analytical and experimental strainsat the other end of the pipe, near the elbow. The analytical strains fall withinthe range of experimental strains. The negative strain before the arrival ofthe pulse is a result of the precursor effects because the wave speed in thepipe wall is faster than in the fluid.

(a)

Solid Line - SRI

ICEPEL, RUN I

700ICEPEL, RUN 2

S I I I

1.5 3.0 4.5 6.0Time, ms

0.150-

0.125-

0.100

U

E 0075

U

Q050.

0.025

07.5 1.5 3.0 4.5 6.0

Time, ms

Fig. 35. Comparison of Analytical and Experimental Strain Histories at Location SG 1 1-SG 1 5 of FirstFlexible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

Solid Line -SRI (a)

ICEPF.L, RUN I

ICEPEL, RUN 2

.nIMpL 1 I I 1 1" 1.5 3.0 4.5 6.0 7.5

Time,ms

0.100

0.075

0.050*

0.025

0

9.0-f025' .. .--

0 1.5 3.0 4.5 6.0Time, mas

7.5 9.0 I5 D

Fig. 38. Comparison of Analytical and Experimental Strain Histories at Location SG16-5G20 of FirstFlexible Pipe of Single-elbow Loop Tests. (a) Test FP-E-101; and (b) Test FP-E-103.

0.100

0.075

- UA1n

it

SRI Experiment (SGII-SG 15)-- -ICEPEL - Analytical

(b)

-01-0.50

0025

0.000

-nnp0

01 f--

7.5 9.0

0.150

0.125

0.100

G050 f

Io

0.025E

0

(b)

AnoyticoI(ICEPEL)

$1..1II1 I I 1I 1

l l l

- -a

Page 40: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

40

Careful examination of the analytical strains at this end of the pipereveals more strains closer to the elbow than farther away from it. Thismay indicate a pressure pulse reflecting from the rigid elbow back to thepipe. Or it may indicate that the fixing of the pipe ends at their junctionswith the elbow led to bulging of the pipe wall in this vicinity, a phenomenaobserved in a statically pressurized cylinder with fixed ends. Because ofthe scatter in the experimental strain data, such a phenomenon cannot beascertained experimentally. This shows the importance of pretest analysisin locating the instrumentations in the experiment.

Similar to the straight-flexible-pipe tests, to investigate the effect ofincreasing the peak pressure of the input pulse on the ICEPEL predictions,only the peak portion of the input pulse of test FP-E-101 was increased by 25%.The results of this run are shown by the chain-dashed lines of part (a) ofFigs 24-36.

Similar results are obtained here, briefly, higher pressure peaksinside the thick-walled pipe, better agreement with experiment on the effectof the rarefaction wave reflecting back from the first flexible pipe on thepressure history at location P3, and insignificant effects on the pressurehistories inside the flexible pipes. The strains at the beginning of the firstflexible pipe are increased and now fall within the experimental strains, asseen in Figs. 33a and 34a. Also, very insignificant changes in strains werepredicted near the elbow.

Page 41: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

41

VII. MODIFICATION OF ICEPEL ELBOW MODEL

The comparison of the analytical and experimental results for thesingle-elbow loop tests has indicated a discrepancy insofar as the radialpressure distribution inside the elbow is concerned. The experiments showedno significant radial pressure variation inside the elbow; the analysis showedpressures near the outer walls of the elbow to be higher than those near theinner walls. The reason for the radial pressure difference is believed to bethe centrifugal-forces effects.

As a consequence, the elbow model is being reinvestigated to resolvethe discrepancy and to demonstrate whether or not a radial pressure varia-

tion of this magnitude is artificiallyRectangular Strip introduced by the assumptions and

approximations made in developingthe model. Hence, it was decided totry a simple elbow model that con-

Circular Strip siders a two-dimensional (r and 9)configuration in which the circularcross section of the elbow is replacedby a stack of equivalent strips each of

a rectangular cross section as shownin Fig. 37. The width of each rectan-gular strip is obtained from the areaof the corresponding circular strip.

The flow inside each rectan-gular strip can be described by the

Fig. 37. Elbow Crop Section standard continuity and Navier-Stokesequations in cylindrical coordinates.

The equations in conservative form, and neglecting gravity forces similar tothose used in the ICE technique, 2 '8 are as follows:

Conservation of Mass

bp1 6i ) 1 b(pv) ., (1)bt r br r e

Conservation of Momentum

Radial Momentum Equation

apu) 1r(u r+ r 6 r br br(P+q) + [bu- J'rv (bt r b 8 rbr ?bee br

Page 42: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

42

Tangential Momentum Equation

b(pv) + 1-b(puvr) + 1 e) +.= 1_ a(P + q) () .bu(3)bt r br r ae r r e + r r lbr e]

In Eqs. 2 and 3,

q = - (x+ Ls)1 + . (4)

In the above equations, p is the mass density, u and v are the radial andtangential velocity components, respectively, P is the pressure, X and pare the first and second coefficients of viscosity of the fluid, respectively,t is the time, and r and e are the radial and tangential coordinates,respectively.

Following the ICE finite-difference scheme, which assigns the densityand pressure to the center of the zones and the velocity components to thecenter of the zone boundaries normal to their directions, the difference formsof Eqs. 2 and 3, the radial and tangential momentum equations, are

(Pu)P.I/l2),j- (Pu) +(1/2 ).j-= Pn+i nl l *n pflat Pi j P+1,j +Ar it j i+, j)

+ CRi+(/z), j (5)

and

(Pv)P,+j+(1/Z) - (PV)i, j+(1/2) . (p+;pn+1) + _ pn )of rp j , # isj+1 riA6 s +

+ CSi, j+(1/z)' (6)

whore

CRi+/ j 7/2 ) = r r rip i, jui-(l/2), j - ri+lpi+1, jui+(s/z), ji+(l/z)

+ rl+(lPl) AO[(Puv)+(lZ),j_(1/z)- (Puv)l+/,)j+(/)]

+ ' [PI+(a/z), jVi+(l/z).j-.(/a)Vi+I/a), j+(l z)] + 1(qi,j - qi+1 , j) (7)i+IZ) (Contd.)

Page 43: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

43

u_+(1/2),_j+1 - 2ui+(1/2), j + ui+(1/z), j-1 ,(Contd.)

ri vj j+(1/2) - vi, j-(1/2) - ri+jvi+1, j+(i/2) - vi+1 , j-(1/2)]+ p r

and

CSL j+(1/2) = 1[ri-/Z)(puv)i-(/2), j+(1/2) - ri+(l)(puv)+(1/2), j+(1/Z)'

Vi,j+(1/) r(p uv)i, j+(1/2)+ Vri j+(i/ LZvi, j(1/2) - p i, j+ivi, J+(3/2) - ri

+ -rie(qi, J "- qi, j+1)

r1 ivhi u ,j+(12)-rivi, j+(1/2)+ i-lvi-1j+(1/2 - rivi, j+(1/2+ e )

+ rri+(/2) +i-(I/2)

+ l [ui+(1/2), j - Ui+(/2), j+1 + ui+(/2), j+1 - .i-((/Z), (8)Arpe ri+1/)ri-(1/2)

In the above equations, i and j are subscripts counting zones in the radialand tangential directions, respectively, n is a superscript counting timecycles, and cp is a time-centering coefficient for the equations of momentum,taking the value between 0 (explicit) and 1 (implicit).

The equation of state in the ICE technique is

P+ = P j + Ci(pi+ -pi(9)

The use of Eqs. 5, 6, and 9 into the difference form of the mass equationresults in

P,+1 + 290 t= + )= CG

[r, + P ,) + r1 - ( P/Z)Fi+,j r'i;j+1 + P+,+ a LtL t + ra6a2 (10)

rior r(60

Page 44: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

44

where

P L 0( - )r+ 1/Z t2

CGicj = '+ rr.+

1, 1

(1 - cP)ri..(Z)tt2 (riArZ ( i J t-P1tjz

+ r -( 1 /Z)CRi- (/2), j - ri+/z>CRi+(/2), j

+ r ri-(1 /2 )(Pu)-( 1 /Z), j - ri+(lZ)(Pu)P+(lZ), j

16+ r?162 P \ 1 P1' J/ rZ g2(P1, 3 Pi,-

+ r A CSi, j_(12 - CSi, j+(1/Z)

+ 11 [(pv )j, j-(1/2) - (Pv) j+(1,2)]j (11)

Equation 10 is a five-point Poisson's equation with only the pressure as anunknown. An iterative solution of Eq. 10 results in the new pressures, whichwhen substituted in Eqs. 9, 5, and 6 result in the new densities and velocities.

The hydrodynamic coupling between the elbow model and the axisym-metric pipe model is achieved by supplying the elbow and the pipe with ficti-tious zones to represent, respectively, the pipe and the elbow. Since theexperimental results confirmed the axisymmetry of the flow in the pipes in

the neighborhood of the elbow, the pressures in the fictitious zones of theelbow are simply considered to be one pressure to be obtained from the con-nected pipe. Such pressure is considered to be an average pressure at apipe section coincident with the center of the elbow fictitious zones and themidplane of the elbow. Axial linear interpolation between two average pres-sures in the pipe is performed whenever the center of elbow fictitious zonesat the midplane of the elbow does not coincide with the center of a pipe zonewhere the pressures are defined in the ICE technique.

The coupling problem now reduces to finding a pressure in the ficti-

tious zones of the pipe from the elbow. This is obtained in such a way thatguarantees the continuity of the mass flow rate between the pipe and th elbow.

In other words, the mass flow rate that leaves the pipe should enter the elbow,and vice versa.

Page 45: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

45

JJUN) Ik)KJUN (a) Figure 38 shows thePIPE KJUIN (k) JJUN{s) junction between a pipe k and

----- ~r'" , an elbow m in a pipe system.Let JJUN(k) refer to the jth in-

AR . Pp p, . dex of the zones inside pipe kJ---m--- and next to the elbow junction,

e 0 and KJUN(k) refer to the jth in-

dex of the pipe junction with theAR .. elbow. Similarly, let JJUN(m)

ELBOW 1.) refer to the jth index of thezones inside elbow m and next

Fig. 38. Pipe and Elbow Hydrodynamic Coupling to its junction with pipe k,

and KJUN(m) refer to the jthindex of the elbow junction with the pipe. Pe is the pressure in the fictitiouszones of the elbow as obtained from the pressures inside the pipe k. Pp isthe pressure in the fictitious zones of the pipe, which is to be determined bysatisfying the mass flow continuity between the pipe and the elbow.

The mass flow rate into the elbow can be expressed as

IEmasse = Aei(peve)9+iiJUN(m), (12)

i=1

where Ae is the area of the ith strip of the elbow cross section, and IE is the

number of radial zones in the elbow.

Using the e-momentum equation (Eq. 6) in the above equation yields

IE

masse = [Aei((Peve), KJUN(m) + rt6Pe+ - PJJUN(m)

1=13

+ - i, JJUN(m) + CSi, KJUN(m))]. (13)

The mass flow rate leaving pipe k can be expressed as

IPmass = (Ap1(ppvp)4UN(k)4)

i=1

where Api is the area of the ith ring in the pipe cross section and IP is the

number of axisymmetric zones in the pipe cross section.

Page 46: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

46

Using the z-momentum equation for the axisymmetric pipe model inEq. 14 results in

IP

masse = [Ap(Ppvp) , KJUN(k) + ktPP,JJUN(k)-PP+]1=1k

+ k PPi JJUN(k) - P + Si, KJUN(k)}. (15)

Equating Eqs. 13 and 15 and solving for p+1 results in

Z IP IE

pn+1 = Y Mp-Z Mei, (16)P i=1 i=1

where Ap is the cross-sectional area of the pipe,

Mp = Api((Ppvp,KJUN(k) + 6t{AZkPPiJJUN(k)

+ j LP~i, JJUN(k) - Pj + Si, KJUN(k)JJ (17)

and

Me = Ae.(peve)i, KJUN(m) + 6t{ e[P+ - Pei,JJUN(m)]

1 - cpF n (18+ r8 e- nNi, JJUN(m) + CSi, (m)1) (18)

For cp = 0, the explicit scheme, the pressure in the fictitious zones ofthe pipe is

Zk IP IE

P + 6tA P1 - Mei) 19__l Mei(19)p=1 1=1

where

Mp Ap{(ppvp), KJUN(k) + 6t [jP~pi, JJUN(k) + Si, KJUN(k) (20)

Page 47: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

47

and

Mei = Aei(p e5e)i KJUN(m) + 6 tPr60 _Pi', JJUN(m)J.

(21)

Equations 13 and 15 are written with respect to the junction local co-

ordinates which assume the positive direction of the flow to be from the pipeto the elbow. Hence for the other junction, where the flow goes from the el-

bow to the pipe, the signs of vPi, KJUN(k)' Si, KJUN(k)' vei, KJUN(m)' and

CSi, KJUN(m) should be reversed.

Equations 16 and 19 indicate that the pressure in the fictitious zonesof the pipe can be obtained explicitly from the values of the field variable in-side the pipe and the elbow. This is done in each iteration with the new pres-

sure calculation.

This modified elbow model has been incorporated in a modified version

of ICEPEL, which was then used to analyze test FP-E-103 for a single-elbowloop. The same 1-in. zone model was used to analyze the test.

The results of the new analysis showed insignificant quantitativechanges in the pressure and strain histories inside the two pipes connectedto the elbow. Consequently, the comparison between the analytical and ex-perimental results of pressures and strains in the straight pipes is practi-

cally the same as in the earlier analysis.

However, inside the elbow, the new model showed no radial variationin the pressure. This agrees with the experimental results, as can be seenin Fig. 39, which compares the analytical results of the pressure history and

the experimental results of gauges P11,

P12, and P13 at the midsection of the

DshLi Line-CEPELP12,nd P13 elbow. The results of the new model4.. -also showed a radial variation in the

tangential velocity inside the elbow,being higher near the inner walls of

". -the elbow than near the outer walls.This tangential velocity distributionis similar to that of a free vortex inwhich yr is approximately equal to a

0 -.5 constant.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0

Time, ms Thus, the new elbow model,

Fig. 39. Comparison of Analytical and Experimental which uses the standard governingPressure Histories at Locations P11-P13 equations in cylindrical coordinates,inside Elbow for Test FP-E-103 shows that, in an elbow connecting

two pipes, in which the flow axisym-

metry is maintained, radial pressure variation due to centrifugal forces isnot dominant during the short time of the fluid transient.

Page 48: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

48

VIII. CONCLUSIONS AND RECOMMENDATIONS

The physical phenomenon of pressure-pulse propagation along pipesis well understood. Plastic pipe wall deformation attenuates pressure peaks

until only peaks of slightly higher magnitudes than the yield pressure of thepipe are transmitted beyond the region of plastic wail deformation. However,the subsequent interaction of the transmitted pulse with the different pipingcomponents and with other pulses in the system can produce pressure pulses.>f higher magnitudes that cause plastic wall deformation to occur anywhere

in the pipe system. Cavitation is also a possible result of the interactionbetween the different pulses in the pipe system.

The sensitivity of the calculated results to the material-properties

representation was demonstrated in the dependence of the transmitted pres-

sur' peaks beyond the region of plastic wall deformation on the yield pressureof the pipe. Higher yield stress results in higher transmitted pressure peaks.The subsequent interaction of these transmitted pressures is thus bound to beoverestimated.

Through the ICEPEL analysis of the five piping tests, it can be con-cluded that, considering the accuracy of the experimental measurements, theICEPEL calculations have agreed generally well with the experimental mea-surements of pressures and strains. Of particular importance here is theaccuracy of the pressure records at P1 which were used as an input to theanalytical models. The pressure records at P2 are not recommended for useas an input source to the analytical models because of the proximity of P2 tothe junction with the flexible test pipe. The pressure record there involvedboth the incident pulse and its interaction with the reflected pulses from the

flexible pipe. It is to be recommended in this respect that for future experi-ments, records to be used as input to the analytical model should be rnea-sured by at least two different gauges.

The modified ICEPEL elbow model, which used the standard Navier-

Stokes equations in r and e coordinates, has shown no radial pressure dis-tribution inside the elbow, in agreement with the experimental results. Thisindicates that the centrifugal-forces effects are not dominant within the shorttransients of the tests. It also indicates that the assumptions and simplifica-tions in the original ICEPEL elbow model hav' artificially introduced the ra-dial pressure distribution inside the elbow. Both models have shown, however,that the flow inside the elbow is localized and has no noticeable effect on theresults in the rest of the piping system.

One discrepancy that remains to be resolved is the attenuation of thepressure-pulse peaks as the pulses propagate along the elbow. The experi-mental results showed much more attenuation than the analysis. The geom-etry of the elbow and the short transition pieces at the ends of the elbow mayhave contributed to the bigger attenuation in the experiments. For this, aprecision elbow test is recommended.

Page 49: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

49

The analysis has shown some indications of pressure pulses reflectingfrom the rigid elbow back to the first flexible pipe. Experimentally, becauseof insufficient dynamic strain measurement close to the elbow, such a con-clusion cannot be made. This indicates the importance of pretest analysis inlocating the instrumentation.

The variation of strain measurements around the circumference of the

pipe cannot be totally due to the nonuniformity of the pipe-wall thicknessaround the circumference. Because of imperfections in the commercial off-the-shelf pipe used and because of the existence of the elbow, bending of the

pipes cannot be ruled out. Thus, it is important to include the flexural stresses

in the structural analysis of piping systems. Also, the preexisting stresses dueto normal operation pressurization, creep, and thermal phenomena need to beincluded in the analysis so that the integrity of reactor piping systems can beensured.

Page 50: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

50

APPENDIX A

Effect of Pipe-wall Thickness on Circumferential Strains

The experimental strain measurements at one axial location of a pipeshowed a wide scatter around the circumference of the pipe. The scatter wasattributed to the variation of pipe-wall thickness around the circumference.The wall thickness was measured before and after the tests at the strain-gaugelocations and varied within 5%. However, the scatter in the strain measure-ments was nowhere close to that. In some instances, a whole order-of-magnitude difference between the largest and smallest strains was recorded.

An analytical investigation on the effect of pipe-wall-thickness variationon the calculated strains is reported here. The ICEPEL code, however, cannothandle thickness variations around the pipe circumference since it uses anaxisymmetric thin-shell model of the pipe walls.

Therefore, the code can only be run twice, once using the smallestmeasured thickness of the pipe walls (0.1575 cm, 0.062 in.) as a uniform thick-ness of the flexible pipe of test FP-SP-102 (as an example), and once usingthe largest measured thickness (0.1727 cm, 0.068 in.). The calculated strainsfor both cases are then compared. The layout and the ICEPEL model oftest FP-SP-102 were described earlier.

1.25 Figure A.1 compares the calculatedstrains for both cases at the beginning ofthe flexible pipe (3.81 cm into flexible pipe,

Thin Pipe location SG-SG). The figure indicates1.00 that the variation in strains is only 15% as

a result of thickness variation of 9.25%.As expected, the thinner walls have predicted

0.15-higher strains than the thicker-wall case.

Thick Pipe Because of the higher yield pressure

of the thicker pipe, the effect on the pres-* 0.50 sure histories in the deformable pipe was

found to have the expected trend, higherpressure peaks for the thicker pipe.

0.25 _Figure A.2 shows that the increase in thetransmitted peak pressure has about thesame ratio, 9.25%, as that of the thickness

variation.

0 1.5 3.0 4.5 At the other end of the flexible pipe,Time, ms near the blind flange, the effect of the thick..

ness variation on the calculated strains isFig. A.1. Analytical Strain Histories at Loca- opposite that at the beginning of the pipe, i.e.,

tion SG1-SG 5, Test FP-SP-1G2 higher strains for the thicker pipe than for

Page 51: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

51

the thinner pipe, as shown in Fig. A.3, which shows the calculated strains atlocation SG 16-SG20 (3.81 cm from the blind flange). This is due to higher re-flected pressure pulse in the thicker-pipe case, a result of the higher yieldpressure of the pipe.

6

5 --

41

CL

2

0 1.5 3.0Time, ms

0.5

0.4 1

0.3 1C

a

0

an

0.2 t

0.I

0

Thick Pipe

- I

Thin Pipe

4.5 0 1.5 3.0Time, ms

4.5

Fig. A.2. Analytical Pressure Histories atLocation P8, Test FP-SP-102

Fig. A.3. Analytical Strain Historiesat Location SG1 6 -SG20,Test FP-SP-102

As shown in Fig. A.2, the transmitted pressure peak beyond the plastic-wall-deformation region is about 9.25% higher in the thicker-pipe case thanin the thinner-pipe case. Consequently, the reflected pressure pulse from theblind flange is about 18.5% higher in the thicker-pipe case. This resulted inonly about 5% more strain near the flange in the thicker-pipe case, as shownin Fig. A.3.

This study, however, does not show the effect of the thickness variationaround the circumference of the pipe on the calculated strains. To analyticallyinvestigate this effect, a pipe section in which the wall thickness varies gradu-ally between the smallest and the largest measured thickness is analyzed by'the STRAW7 structural code, which uses a similar finite-element structuralanalysis to that used in the structural part of the ICEPEL code.

-0.i

Thick Pipe

Thin Pipe

-I

v I

ONE

Page 52: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

52

Because of symmetry, only half the pipe section is modeled, as shownin Fig. A.4. Thirty-six beam elements are used to model the circumferenceof the pipe. The heights of the beam element (representing the pipe-wallthickness) are varied in seven equal steps between 0.1575 and 0.1727 cm(0.062 and 0.068 in.), according to Table A.1. The pipe whose radius is 3.65 cmwas uniformly subjected to a simple triangular pulse of 9.0-MPa peak pressureand 50-ps rise and fall times.

16 4

P .. MPa

0 50 100t, 215

Fig. A.4. STRAW Model of Variable-thickness Pipe

TABLE A.l. Heights of Beam Elements ofSTRAW Model of Pipe Circumference

Element Height of Beam Element,No. cm(in.)

1-5 0.1575 (0.062)6-10 0.1600 (0.063)

11-15 0.1626 (0.064)16-20 0.1651 (0.065)21-25 0.1676 (0.066)26-30 0.1702 (0.067)31-36 0.1727 (0.068)

Table A. 2 shows the variation in the calculated strains between thethinnest and the thickest elements at different times. The results indicatethat variation in strains did not exceed 45% for a thickness variation of 9.257o.

Page 53: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

TABLE A.2.2 Calculated Strains of Thinnest and Thickestat Various Times

Elements

Smallest Strain, Largest Strain, PercentageTime, pis % TVariation

15 0.0147 0.0162 9.130 0.0644 0.0749 15.145 0.147 0.197 29.160 0.339 0.459 30.175 0.579 0.784 30.190 0.739 1.06 35.7

105 0.704 1.11 44.8120 0.69 0.972 33.9135 0.695 1.06 41.6150 0.719 1.08 40.1

Table A.3 summarizes the SRI strain and thickness measurementsfor the four plastic piping tests performed. The strain variation is seen tobe mostly more than those resulted analytically. Also, no consistency is ob-served between the thickness variation and the strain variation. Widelydifferent strain variations were recorded for the same thickness variation.

TABLE A.3. Summary of Measured Thicknesses and Variations in Recorded MaximumDynamic Strain in SRI Piping Tests

SG -SG 5 SG6-SGIo SG-SG1 SG -SGao

Thickness Strain Thickness Strain Thickness Strain Thickness StrainVariation, Variation, Variation, Variation, Variation, Variation, Variation, Variation,

Test % % % % % % % %

SP-101 4.7 43.2 6.2 96.6 4.7 133.3 4.5 79.2SP-102 9.2 31.0 10.7 30.8 7.8 120.0 10.7 108.8E-101 6.3 42.6 4.6 57.8 7.6 76.9 9.2 123.8E-103 ".6 140.6 3.0 176.0 7.6 169.2 6.2 200.0

Thus, it can be concluded that the thickness variation is not the onlymajor source of strain variations around the circumference. Another sourceis the bending effects that are superimposed on the stresses due to internalpressurization and that result from possible imperfections in the test pipesand changes in flow direction due to the elbow. Such effects are not includedin the ICEPEL code analysis of piping systems. However, such effects areplanned in the near future.

53

Page 54: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

54

APPENDIX B

Effect of Pipe Material-properties Representation on ICEPEL Calculations

As discussed in Sec. V of this report, it is important to represent thestress-strain relationship for the pipe-wall material by the correct yieldstress in order to correctly predict the consequences of the interaction ofthe transmitted pressure pulses with the different piping component and withother pulses. The study that led to this conclusion is presented here.

1.5 3.0 4.5 6.0

Stroln,%

7.5 9.0

Fig. 8.1. Stress-Strain Approximationsfor Nickel-200

If we use the straight-flexible-pipe test FP-SP-102 asan example and its model as de-scribed in Sec. IV of this report,the stress-strain relationship fornickel-200 is described by the re-lations shown in Fig. B.1. Thesolid line represents a bilinearrelation with a high yield stressof 96.5 MPa (14,000 psi), thedashed line is a bilinear relation

10.s with a lower yield stress of86.2 MPa (12,500 psi), and thedotted line is a trilinear rela-tion with an even lower yield stressof 75.8 MPa (11,000 psi).

The results of the three different runs are summarized in Fig. B.2,which shows the deformed pipe configuration of the three runs. The transmittedpressure beyond the region of plastic deformation is reduced by reducing theyield stress. Consequently, the strains at the blind flange of the pipe are alsoreduced, since they result from the reflected pressure pulse. However, thestrains at the beginning of the pipe are not significantly affected by the changesin the yield stress of the material.

Fig. B.?

PLpe-wall Configuration at 4 ms

0 10 40 60 0 100 10 140Length alga, flalble Plpem

500

400

300

200

100

(0

sol-d-High-yield Bilineardash-Low-yield Bilinear -

- dot-Multllinearf

- "

of0.0

0.05

0.04

I 0.03

"S

w0w.

- High-yield B""n'--- Low-yield Slines

.------ M1ltIllnger

- .uuu$ r

01w

Ll

,rL-

Page 55: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

55

APPENDIX C

Effect of Zone Size and Time Step on ICEPEL Calculations

The straight-flexible-pipe test FP-SP-102 is used here to investigatethe effects of different analytical models on the performance of the ICEPELcode. The changes among models involve the axial zone size and the time .step.

In all different models to be discussed, the pressure pulse as recordedby the pressure transducer at location P1, 76.2 cm (30 in.) from the pulse gun,is considered as an input pulse applied to the pipe downstream from location Pl.Table C.1 summarizes the different input parameters of the five models.

TABLE C.l. Summary of Input Parameters for the Five Models

Model

1 2 3 4 5

Number of Radial Zones 2 2 2 2 2

Number of Axial Zones 200 150 100 100 50

Total Number of Zones 808 608 408 408 208

Axial Zone Size, cm 1.905 2.54 3.81 3.81 7.62(in.) (0.75! (1) (1.5) (1.5) (3.0)

Hydrodynamical TimeStep, s 4 5 8 4 4

Structural TimeStep, Ps 2 2.5 4 4 4

Number of HydrodynamicCycles 2000 1604 1000 2000 2000

Number of StructuralCycles 4000 3208 2000 2000 2000

Table C.1 indicates that, in the first three models, the hydrodynamicand structural time steps were chosen so that two structural calculationalcycles are performed within each hydrodynamic calculational cycle. In thelast two models, one structural calculational cycle is performed within eachhydrodynamic calculational cycle.

The stress-strain relationship for Nickel-ZOO In approximated by athree-straight-line segmented curve described in Table C.2.

TABLE C.Z. Stress-Strain Approximation for Nickel-200

Stress at End of Strain at End ofSegment, MPa Segment, cm/cm

Segment 1 75.84 0.000393

Segment 2 96.5 0.001675

Segment 3 472.5 0.1

Page 56: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

56

Figure C.1 shows the configuration of the flexible pipe wall at about8 ms as obtained by all models. At this time, the pressure pulse had almostdied in the system; thus, it represents the final wall configuration of theflexible pipe.

The figure reveals that the first four models have generally predictedthe same results. At the beginning of the flexible pipe, however, comparisonof the results of the first three models shows that the longer the length of thewall segment, the stiffer the structure becomes, which is to be expected. Thisgenerally leads to slightly higher pressures transmitted downstream, which inturn results in higher deformation.

This is more clearly shown in Table C.3, which compares the pressurepeaks at three locations in the flexible pipe for models 4 and 5. The differencediminishes as the distance along the pipe increases.

A comparison of models 3 and 4 shows that decreasing the hydro-dynamic time step led to higher pressure peaks in the rigid pipe: 10.8 MPafor model 4, compared to 9.45 MPa for model 3. This confirms that in finite-difference solutions, increasing the time step reduces the resolutions ofpressure pulses.

The reflected pressure pulse from the blind rigid flange caused moreplastic deformations to occur in this vicinity. However, the first four modelsconsistently showed that the point of maximum wall deformation is somewhatbetween 2.54 and 5.08 cm (1 and 2 in.) from the flange. This bulge is causedby the fixed-end condition used at the flange. The same behavior was observedin a statically loaded cylinder with fixed ends.6

Unfortunately, strain gauges SG16 -SG2 0 were located in the same regionwith no other gauges nearby. This signals the importance of pretest analysisfor the experimentalist in locating instrumentation.

Table C.4 summarizes some of the code performance parameters forall models. For models 1-3, in which two structural calculational cycles wereperformed within each hydrodynamic calculational cycle, the CPU (centralprocessing unit) times per cycle per zone were almost equal. Thus, the totalCPU time is directly proportional to the total number of zones (includingfictitious zones) and the number of hydrodynamic cycles.

Thus, it is in the best interest of economy to use a smaller number ofzones and larger time steps, as long as there is no significant effect on theaccuracy of the results. As regards numerical stability for the structuralcalculations, the smaller the zones the smaller the time step needed.

Page 57: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

0.04

0.03EUI

0P

0

zhiz

WOA

LOCATION, CM

O " I6 24 32 40 48 56 64 72 80 86 96 104 112 120 128 136 144 152

0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 SI 54 57 60LOCATION, in.

Fig. C.1. Wall Configuration of Flexible Pipe at 8 ms. ANL Neg. No. 900-77-744.

U

i

I I I I I I I I I I 1

*"

o MODEL I

" MODEL 20 0 MODEL 3

A MODEL 4

0 MODEL0

0vp

-So-

moR?Qft aoo

Aft.L

Page 58: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

58

TABLE C.3. Peak Pressures for Models 4 and 5

Distance into Flexible Model 4 Model 5Pipe, cm (in.) Pressure, MPa Pressure, MPa

3.81 (1.5) 5.51 6.27

15.24 (6) 4.93 5.15

121.9 (48) 5.0 5.05

TABLE C.4. Summary of Some Performance Parameters for ICEPEL Code

Model

1 2 3 4 5

Total Number of HydrodynamicIterations 19,106 15,042 11,686 16,328 16,652

Average Number of Iterationsper Hydrodynamic Cycle 9.55 9.37 11.69 8.16 7.826

Total CPU Time, s 1626 966 417 517 247

CPU Time per Cycle per Zone, ms 1.006 0.997 1.022 0.633 0.593

A comparison of results for models 3 and 4, in which the total numbersof zones were the same, shows that the reduction of the hydrodynamic timestep led to better results, insofar as the pressure-peak resolution and strainare concerned, and reduced the CPU time per cycle per zone by about 37%,while increasing the total CPU time only by about 24%.

Code economy can be further improved by increasing the safety factorused in calculating the maximum structural time step from 50 to 80%. Thiswas tried on model 2 and resulted in about 25% savings in the total CPU time.

Although the ICEPEL code is two-dimensional, it can be used for one-dimensional modeling of pipes by using only one radial zone in the pipe.

The conventional one-dimensional methods, which consider the walldeformation only from the fluid viewpoint by adjusting the compressibilityaccordingly, do not perform a fluid-structure-interaction coupling calculationor structural calculation for the walls. Thus, the bending effects between wallsegments are not accounted for, and the precursor effect due to the differentwave speeds in the wall and in the fluid is ignored; i.e., the stress wave travel-ing through the wall is ignored. However, the above phenomena are automati-cally included in the ICEPEL one-dimensional calculation without undue penaltyin running time.

Page 59: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

59

ACKNOW LEDGMENTS

The experiments were designed and portions of the analysis oftest FP-SP-102 were performed by G. Nagumo. Thanks are due toDr. S. H. Fistedis for his encouragement and support and to Dr. Y. W. Changfor his valuable discussions during this study.

REFERENCES

1. M. T. A-Moneim, Coupled Hydrodynamic-Structural Response Analysis of PipingSystems, ANL-77-91 (Feb 1978).

2. F. H. Harlow and A. A. Amsden, A Numerical Fluid Dynamics CalculationMethod for All Flow Speeds, J. Comput. Phys. 8, 197-213 (1971).

3. T. Belytschko and B. J. Hseih, Nonlinear Transient Finite Element AnalysiswithConvected Coordinates, Int. J. Numer. Methods Eng. 7, 255-271 (1973).

4. C. M. Romander and D. J. Cagliostro, Experiments on the Response ofFlexible Piping Systems to Internal Pressure Pulses, SRI Fourth InterimReport (Apr 1976).

5. D. J. Cagliostro and T. J. Marciniak, "A Pressure Source for Loading Sub-assembly Ducts," Trans. Third SMiRT Con f., Vol. 2, Part E, Paper E 1/2(Sept 1975).

6. J. S. Dean, Approximate Calculations for the Radial Expansion of ThinTubes Used in Pressure Transducers, J. Strain Anal. 8(4), 264-266 (1973)'.

7. J. M. Kennedy, Nonlinear Dynamic Response of Reactor-core Subassemblies,ANL-8065 (Jan 1974).

8. M. T. A-Moneim, ICEPEL, A Two-Dimensional Computer Program for theTransient Analysis of a Pipe-Elbow Loop, ANL-75-35 (July 1975).

Page 60: Distribution Category: (UC-79p) ANL-78-105 NATIONAL …/67531/metadc303854/m2/1/high_res... · Recent advances in computer technology have led to the wide use of computer codes in

60

Distribution for ANL-78-105

Internal:

J. A. KygerL. BurrisD. W. CisselS. A. DavisB. R. T. Frost

D. C. RardinR. J. TeunisC. E. TillR. S. ZenoH. O. MonsonR. Avery

J. F. Marchaterre

A. J. GoldmanH. K. FauskeI. Bornstein

B. A. Korelc (3)D. Rose

T. C. ChawlaR. A. Valentin

L. BakerP. A. LottesR. H. SevyW. C. LipinskiD. H. ChoL. W. DeitrichS. H. FistedisD. R. FergusonD. Myers (5)R . A. NolandC. E. DickermanA. E. KlickmanJ. B. HeinemanJ. E. AshY. W. ChangH. Y. ChuC. FialaJ. L. GlazikJ. GvildysC. K. Youngdahl

C. A. KotJ. M. KennedyR. F. KulakA. H. MarchertasM. T. A-Moneim (28)H. J. PetroskiH. L. SchreyerC. Y. WangW. ZeuchA. B. RothmanA. DeVolpiR. E. HenryD. H. LennoxJ. H. TessierD. R. PedersenA. B. KrisciunasANL Contract FileANL Libraries (5)TIS Files (6)

External:

DOE-TIC, for distribution per UC-79p (251)Manager, Chicago Operations OfficeChief, Office of Patent Counsel, CHDirector, Reactor Programs, CHDirector, CH-INELDirector, DOE-RR T (2)President, Argonne Universities AssociationReactor Analysis and Safety Division Review Committee:

S. Baron, Burns and Roe, Inc.J. R. Dietrich, Combustion Engineering, Inc.W. Kerr, U. MichiganM. Levenson, Flectric Power Research Inst.S. Levy, S. Levy, Inc.D. Okrent, U. California, Los AngelesN. C. Rasmussen, Massachusetts Inst. Technology