Upload
karim-senhaji
View
19
Download
1
Embed Size (px)
Citation preview
Camille Bauer
Cam
ille
Bau
er A
G
Heavy currentengineering
Angular positionengineering
Process controlengineering
Rely on us.
Rely on us.
Camille Bauer Ltd
Aargauerstrasse 7
CH-5610 Wohlen / Switzerland
Phone: +41 56 618 21 11
Fax: +41 56 618 35 35
www.camillebauer.com
Heavy CurrentEngineering
Sub
ject
to c
hang
e w
ithou
t not
ice
SM
-10
21-
00
0-0
2-E
N-0
9.1
0
Rely on us.
Camille BauerHeavy Current Engineering at a glance
Camille BauerOur Sales Partners
Only the best have always been working for
us, i.e. our customers and the market with
all of its changing and new challenges. This
implies a permanent learning aptitude which
is consistently implemented in our products
- particularly in customised solutions. And
this world-wide, always considering local
requirements, conditions and regulations.
We launch new products as announced. We
adhere strictly to confirmed delivery dates.
And: Our responsibility in relation to customers
does not end upon the conclusion of a sale.
Systematic and innovative thinking determines
our actions. The concept of all product groups is
comprehensive and integrative.
In this respect, high priority is given to the
interaction of hardware and software.
Our program may be subdivided as follows:
• Heavy current engineering
• Angular position engineering
• Process control engineering
Camille Bauer offers two options for orders:
The versatile products of Camille Bauer have
different product features. You can obtain
products via Order Code or as stock versions.
The Order Code is stated on the data sheets on
our homepage:
www.camillebauer.com.
For standard applications, use the 6-digit
Article Number stated in this catalogue. These
products are on stock and can be supplied
within 3 days.
It is a matter of course that our competent sales
partners in your country will support you in
ordering (please see the inside of the rear cover
or visit our homepage).
Our in-house area sales manager will support
you in countries which are not listed.
Rely on us:
We provide a
3-year warranty for all
Camille Bauer products.
Unifunctional transducers
Multifunctional transducers
Displaying power meters
Energy management
Software, accessories, basics
Indices
Heavy currentengineering
Angular positionengineering
Process controlengineering
Germany
GMC-I Messtechnik GmbH
Südwestpark 15
D-90449 Nürnberg
Phone +49 911 8602 - 111
Fax +49 911 8602 - 777
www.gossenmetrawatt.com
France
GMC-Instruments France SAS
3 rue René Cassin
F-91349 MASSY Cedex
Phone +33-1-6920 8949
Fax +33-1-6920 5492
www.gmc-instruments.fr
Italy
GMC-Instruments Italia S.r.l.
Via Romagna, 4
I-20046 Biassono MB
Phone +39 039 248051
Fax +39 039 2480588
www.gmc-instruments.it
Netherlands
GMC-Instruments Nederland B.V.
Postbus 323, NL-3440 AH Woerden
Daggeldersweg 18, NL-3449 JD Woerden
Phone +31 348 421155
Fax +31 348 422528
www.gmc-instruments.nl
Switzerland
GMC-Instruments Schweiz AG
Glattalstrasse 63
CH-8052 Zürich
Phone +41-44-308 80 80
Fax +41-44-308 80 88
www.gmc-instruments.ch
Spain
Electromediciones Kainos, S.A.U.
Energía 56, Nave 5
E-08940 Cornellà -Barcelona
Phone +34 934 742 333
Fax +34 934 743 447
www.kainos.com.es
Czech Republic
GMC-měřicí technika s.r.o
Fügnerova 1a
CZ-678 01 Blansko
Phone +420 516 482 611-617
Fax +420 516 410 907
www.gmc.cz
USA
Dranetz
1000 New Durham Road
Edison, New Jersey 08818-4019, USA
Phone +1 732 287 3680
Fax +1 732 248 1834
www.dranetz.com
Electrotek Concepts Inc.
9040 Executive Park Drive, Suite 222
Knoxville, TN 37923-4671, USA
Phone +1 865 470 9222
+1 865 531 9230
Fax +1 865 470 9223
+1 865 531 9231
www.electrotek.com
Daytronic Corporation
2566 Kohnle Drive
Miamisburg, Ohio 45342, USA
Phone +1 937 866 3300
Fax +1 937 866 3327
www.daytronic.com
China
GMC-Instruments (Tianjin) Co., Ltd
www.gmci-china.cn
Beijing
Rm.710, Jin Ji Ye BLD. No.2,
Sheng Gu Zhong Rd.
P.C.: 100022, Chao Yang District
Phone +86 10 84798255
Fax +86 10 84799133
Tianjin
BLD. M8-3-101, Green Industry Base,
No.6, Hai Tai Fa Zhan 6th Rd.
P.C.: 300384, Nan Kai District
Phone +86 22 83726250/51/52
Fax +86 22 83726253
Shanghai
Rm. 506 Enterprise Square BLD. No.228,
Mei Yuan Rd.
P.C.: 200070, Zha Bei District
Phone +86 21 63801098
Fax +86 21 63801098
3
17
29
41
59
70
Current transducers
Voltage transducers
High-voltage isolation amplifiers for DC variables
Power transducers
Frequency and phase angle
Introduction
Overview
Multi-transducer M56x
Multi-transducer line DME4
Universal measuring unit CAM
Accessories for multi-transducer line DME4
Overview Displaying power meters, extendable by modules
Displaying power meters,
„All in one“
Accessories for A210, A220, A230s, A230
Energy meters
Energy Control System (ECS)
Summators
Additional components for summators
Load optimisation
Power quality
Software for heavy current transducers and power meters
Software for energy management
Accessories for heavy current transducers and power meters
Electromagnetic compatibility
Environmental testing
Products of angular position engineering
Products of process control engineering
Index Our sales partners
2
3Current transducersCommon features ....................................................................................................................... 4
I542 ........................................................................................................................................... 5
I538 ........................................................................................................................................... 5
I552 ........................................................................................................................................... 6
Voltage transducersCommon features ....................................................................................................................... 7
U543 ......................................................................................................................................... 8
U539 ......................................................................................................................................... 8
U553 ......................................................................................................................................... 9
U554 ......................................................................................................................................... 9
U700, AC voltage difference ...................................................................................................... 10
High-voltage isolation amplifiers for DC variablesTV829 ...................................................................................................................................... 10
Power transducersCommon features ..................................................................................................................... 11
P530/Q531, Active or reactive power ......................................................................................... 11
P200, Active or reactive power................................................................................................... 12
P600, Mixed current power ....................................................................................................... 12
Frequency and phase angleF534, Frequency ....................................................................................................................... 13
F535, Frequency difference ....................................................................................................... 14
G536, Phase angle or power factor ............................................................................................ 15
G537, Phase angle difference .................................................................................................... 16
Content Unifunctional Transducers
Camille BauerUnifunctional Transducers
4For the conversion of a sinusoidal alternating current into a proportional DC signal.
Customer benefit• Determinationofthevariableloadoflinesandequipment• Identificationoftheutilisationratiobyacomparisonwiththenominalcurrent• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationThetransducersforalternatingcurrentoftheP-linearetypicallyconnectedviacurrenttransformers,butcanalsobeusedfordirectmeasurement.Themeasurementiseffectedwithintheinstrumentviacurrent transformers which ensure galvanic isolation. The instruments are designed for sinusoidal alternatingcurrentsignals.Possiblyexistingdirectcurrentportionsarenotconcurrentlymeasured.They provide an output signal in form of a direct current signal which is proportional to the measured current.Theinstrumentscanbeeasilysnappedontoatop-hatrail(35x15mmor35x7.5mm).
Overview of instruments O=optional,S=standard
Special features I542 I538 I552
Input Measurement of distorted alternating currents •
RMSvaluemeasurement(standard) •
2measuringranges(standard) • •
Adjustablemaximumvalueofthemeasuringrange O O S
Withoutpowersupply(standard) •
Nominalfrequency400Hz(option) •
Output Settingtime300ms • • •
Settingtime50ms(option) •
Adjustableoutputsignal(option) • •
Live-zerooutputsignal(option) • •
Power supply
2-wiretechnologywith4…20mAoutput(option) •
ForcurrentmeasurementwithsignprogrammabletransducersoftheDME4orM56xlinesmaybeused.
Live-zero output signalIncaseofinputsignalzerothepertainingoutputsignalisnon-zero,bydefinition,e.g.4mAwitha4…20mAoutputsignal.Thispermitsmonitoringtheinstrumentoperationinaveryeasymannersinceanoutputvalueof0mAclearlyindicatesanerror.Thismightbethefailureofthepowersupplyoranabsentinputsignalcausedbyaninterruptionofasignalline.
2-wire technologyTransducersin2-wiretechnologydonotrequireaseparatepowersupplyconnection.Theyaresupplied via the output circuit. Instruments designed in this way must operate with less than 4 mA supplycurrentbutdonotneedseparateelectronicsforthepowersupply.
Short-circuiting of current transformersConventional current transformers have a ferrite core. If the secondary winding of the transformer is open, it might carry high voltages, which will drive the current transformer to saturation. This might leadtoflashoversandheatlossesbyeddy-currentsandmagnetichysteresislosseswhichcouldcause a permanent loss in transformer accuracy. In extreme cases it is even destroyed. Therefore, thecurrentinputofthecurrenttransducer(andallothertransducerswithcurrentinputs)shouldalwaysbeconnectedviashort-circuitingterminals.
Transducers for alternating current: Common features
Camille BauerCurrent Transducers
5SINEAX I542
SINEAX I538
To measure sinusoidal alternating currents, without power supply connection.
Customer benefit• Withoutpowersupplyconnection,lowwiringexpenditure• StandardasGL(GermanischerLloyd),suitableforships
Technical dataMeas.input: 0…1A/5A,0…1.2A/6Aorcustomised(0…0.5Ato0…7.5A,
onlyonemeasuringrange),nominalfrequency50/60HzMeas.output: 0…1mA,0…5mA,0…10mA,0…20mAor0…10Vor customised(0…1Vto0…<10V)Accuracy: Class0.5at15…30°CH x W x D: 69.1 x 35 x 112.5 mm
Stock variants
Article No. Measuring range, switchable Output signal
129 595 0…1A/5A 0…5mA
129 602 0…1A/5A 0…10mA
129 610 0…1A/5A 0…20mA
136 417 0…1.2A/6A 0…5mA
136 425 0…1.2A/6A 0…10mA
136 433 0…1.2A/6A 0…20mA
TomeasurecurrentswithhighharmoniccontentordistortedsinusoidalformSINEAXI552shouldbeused.
Camille BauerCurrent Transducers
To measure sinusoidal alternating currents, with power supply connection.
Customer benefit• Alsoavailableincost-effective2-wiretechnology• StandardasGL(GermanischerLloyd),suitableforships
Technical dataMeas.input: 0…1A,0…5Aorcustomised0…0.8Ato0…1.2Aor0…4Ato0…6A,
nominal frequency 50/60 HzMeas.output:: 0…20mA,4…20mA,4…20mA2-wiretechnology,0…10VorcustomisedAccuracy: Class0.5at15…30°CPower supply: 24 – 60 V AC/DC, 85 – 230 V AC/DC or 24 V, 110 V, 115 V, 120 V, 230 V, 400 V AC 50/60 Hz or 24VDCor24VDCviaoutputcircuitin2-wiretechnologyH x W x D: 69.1 x 35 x 112.5 mm
Stock variants
Article No. Measuring range Output signal Power supply
137 431 0…1A 4…20mA 230VAC,4-wireconnection
137 449 0…5A 4…20mA 230VAC,4-wireconnection
146 979 0…1A 4…20mA 24VDC,4-wireconnection
136 590 0…1A 4…20mA 24VDC,2-wiretechnology
146 987 0…5A 4…20mA 24VDC,4-wireconnection
136 607 0…5A 4…20mA 24VDC,2-wiretechnology
TomeasurecurrentswithhighharmoniccontentordistortedsinusoidalformSINEAXI552shouldbeused.
Transducer for alternating current
Transducer for alternating current
6 SINEAX I552
To measure sinusoidal or distorted alternating currents, with power supply connection.
Customer benefit• RMSvaluemeasurementuptocrestfactor6• 2measuringranges• Possibilityofadjustingthemaximumvalueofthemeasuringrangeonsite• StandardasGL(GermanischerLloyd),suitableforships• Canalsobeusedfor400Hzsystems
Technical dataMeas.input: 0…1A/5A,0…1.2A/6Aor
customised(0…0.1/0.5Ato0…<1.2/6A) Nominal frequency 50/60 Hz or 400 HzMeas.output: 0…20mA,4…20mA,0…10Vorcustomised Settingtime50msor300msAccuracy: Class0.5at15…30°CPower supply: 24 – 60 V AC/DC, 85 – 230 V AC/DC or 24VAC/24–60VDC,connectiononthelow-voltagesideH x W x D: 69.1 x 70 x 112.5 mm
Stock variants
Article No. Measuring range, switchable
Output signal Power supply Setting time
133 760 0…1/5A,50/60Hz 4…20mA 85 – 230 V,DC or 40 – 400 Hz
300 ms
Camille BauerCurrent Transducers
Transducer for alternating current
7For the conversion of a sinusoidal alternating voltage into a proportional DC signal.
Customer benefit• Determinationofthepresentvoltagelevel• Determinationoftheloadoftheequipmentbyacomparisonwiththeratedvoltage• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationThetransducersforalternatingvoltageoftheP-linemaybeconnectedviavoltagetransformers,butcanalsobeusedfordirectmeasurement.Theyhavebeendesignedforthemeasurementofsinusoidalalternatingvoltagesignals.Possiblyexistingdirectvoltageportionsarenotconcurrentlymeasured. They provide an output signal in form of a direct current signal which is proportional to the measured voltage level. Instrumentswithlive-zerosignalcanbeusedforimprovedfailurerecognition.Ifonlycertainareasofthe whole measuring range are of interest, U554 with main value magnification or step point.
Theinstrumentscanbeeasilysnappedontoatop-hatrail(35x15mmor35x7.5mm).
Overview of instruments
Special features U543 U539 U553 U554
Input Measurement of distorted alternating voltages • •
RMSvaluemeasurement(standard) • •
Nominalfrequency400Hz(option) • •
Adjustablemaximumvalueofthemeasuringrange(option)
• • •
Output Live-zerooutputsignal(option) • • •
Settingtime300ms • • • •
Settingtime50ms(option) • •
Different characteristics (primaryvaluescale,step)
•
Power supply
Withoutpowersupply(standard) •
2-wiretechnologywith4…20mAoutput(option)
•
Camille BauerVoltage Transducers
Transducers for alternating voltage: Common features
8 SINEAX U543
SINEAX U539
Camille BauerVoltage Transducers
To measure sinusoidal alternating voltages, without power supply connection.
Customer benefit• Cost-effectivemeasurementofvoltageswithlowharmoniccontent• Withoutpowersupplyconnection,lowwiringexpenditure
Technical dataMeas.input: Differentrangesfrom0…100/√3to0…500Vorcustomized 0…20Vto0…600V,maximum300Vnominalvalueofthesystemagainstearth Nominal frequency 50/60 Hz Maximumvalueofthemeasuringrangeisfixedorcanbesetviapotentiometer
(approx.±10%)Meas.output: 0…1mA,0…5mA,0…10mA,0…20mAor 0…10Vorcustomised(0…1Vto0…<10V)Accuracy: Class0.5at15…30°CH x W x D: 69.1 x 35 x 112.5 mm
Stock variants
Article No. Description Output signal
129 785 0…100V,50/60Hz
0…20mA137 142 0…120V,50/60Hz
129 842 0…250V,50/60Hz
136 459 0…500V,50/60Hz
TomeasurevoltageswithhighharmoniccontentordistortedsinusoidalformSINEAXU553orU554shouldbeused.
To measure sinusoidal alternating voltages, with power supply connection.
Customer benefit• Cost-effectivemeasurementofvoltageswithlowharmoniccontent• Possibilityofadjustingthemaximumvalueofthemeasuringrangeonsite
Technical dataMeas.input: 0…100V,0…250V,0…500Vorcustomised0…50Vto0…600V Nominal frequency 50/60 HzMeas.output: 0…20mA,4…20mA,4…20mA2-wiretechnology,0…10VorcustomisedAccuracy: Class0.5at15…30°C,Class1ifUn>500VPower supply: 24 – 60 V AC/DC, 85 – 230 V AC/DC or 24 V, 110 V, 115 V, 120 V, 230 V, 400 V AC 50/60 Hz or 24VDCor24VDCviaoutputcircuitin2-wiretechnologyH x W x D: 69.1 x 35 x 112.5 mm
Stock variants
Article No. Measuring range Output signal Power supply
146 995 0…100V,50/60Hz 4…20mA
230VAC,4-wireconnection147 000 0…250V,50/60Hz 4…20mA
147 018 0…500V,50/60Hz 4…20mA
136 699 0…100V,50/60Hz 4…20mA24VDC,2-wireconnection
126 971 0…500V,50/60Hz 4…20mA
TomeasurevoltageswithhighharmoniccontentordistortedsinusoidalformSINEAXU553orU554shouldbeused.
Transducer for alternating voltage
Transducer for alternating voltage
9SINEAX U553
SINEAX U554
Transducer for alternating voltage
To measure sinusoidal or distorted alternating voltages, with power supply connection.
Customer benefit• RMSvaluemeasurementuptocrestfactor6• Possibilityofadjustingthemaximumvalueofthemeasuringrangeonsite• StandardasGL(GermanischerLloyd),suitableforships• Canalsobeusedfor400Hzsystems
Technical dataMeas.input: Differentrangesfrom0…100/√3to0…500Vorcustomized 0…20Vto0…690V,maximum400Vnominalvalueofthesystemagainstearth Nominal frequency 50/60 Hz or 400 Hz Maximumvalueofthemeasuringrangecanbesetviapotentiometer
(approx.±15%)Meas.output: 0…20mA,4…20mA,0…10Vorcustomized 0…1to0…20mAor0.2…1to4…20mAor 0…1to0…10mAor0.2…1to2…10V Settingtime50msor300msAccuracy: Class0.5at15…30°CPowersupply: 24–60VAC/DCor85–230VAC/DC(alsofrommeasurementinput)or 24VAC/24–60VDC,connectiononthelow-voltagesideH x W x D: 69.1 x 70 x 112.5 mm
Transducer for alternating voltage
To measure sinusoidal or distorted alternating voltages, with power supply connection.
Customer benefit• RMSvaluemeasurementuptocrestfactor6• Themeasuringrangewhichisofinterestcanbehighlighted
Technical dataMeas.input: Minimumvalue0V,maximumvalueofthemeasuringrangeE3=20…690V,
Steppoint0.1·E3…0.9·E3 Nominal frequency 50/60 Hz or 400 HzMeas.output: MaximumvalueA3=1mA,5mA,10mA,20mA,10Vorcustomised1…20mA
or1…10V
E1 E3
A1
A3
E
A
E2
A2
E1 E3
A1
A3
E
A
E2
A2
E1 = 0 E1 = 0 0,1 · E3 ≤ E2 ≤ 0.9 · E3 0.1 · E3 ≤ E2 ≤ 0.9 · E3 A1 = 0 A1 = 0.2 · A3 A1 ≤ A2 ≤ 0.9 · A3 A1 ≤ A2 ≤ 0.9 · A3
Accuracy: Class0.5at15…30°CPowersupply: 24–60VAC/DCor85–230VAC/DC(alsofrommeasurementinput) 24 V, 110 V, 115 V, 120 V, 230 V, 400 V AC 50/60 Hz or 24VAC/24–60VDC,connectiononthelow-voltagesideH x W x D: 69.1 x 70 x 112.5 mm
Camille BauerVoltage Transducers
10 SINEAX U700
EURAX U700
SINEAX TV829
Transducer for alternating voltage difference
High-voltage isolation amplifier for up to 3.6 kV DC
Measures the alternating voltage difference of 2 galvanicly isolated systems.
Customer benefit• Auxiliaryvariabletosynchronisetwosystems• Themeasuringrangewhichisofinterestcanbehighlighted
Technical dataMeas.input: VoltagesofUn=10…500V,measuringrange±20%Un Nominal frequency 50 or 60 HzMeas.output: 0…1mAto0…20mAor1…5mAto4…20mA unipolar,bipolar,live-zeroAccuracy: Class 0.5 Powersupply:AC:115Vor230V±20%,42–70Hz DC:24–110V,-15%…+33%H x W x D: 125 x 70 x 126 mm or plug-incardinEuropeanformat,faceplatewidth7TE(EURAX)
For19”assemblyrackforEURAXplug-incardsseePage28
for shunt and voltage measurement on high potential.
Customer benefit• SafegalvanicisolationaccordingtoDINEN61010-1andDINEN50124(Cat.III)• Hightestvoltage:10kV• Calibratedrangeshift• Highcommon-moderejectionratio:150dB
Technical dataInput(switch-over):: ±60mV,±90mV,±150mV,±300mV,±500mV,±10V 1
±400V,±600V,±800V,±1000V,±1200V ±1400V,±1600V,±1800V,±2000V,±2200V,±3600V 2
Output(switch-over):: 4…20mA,±20mA,±10VPower supply: 24 – 253 AC/DCHxWxD: 90x22.5x118mm(ArticleNo.158312) 90x67.5x118mm(ArticleNos.158320to164004)
Stock variants
Article No. Description
158 312 Shuntmeasurement:±60mV,±90mV,±150mV,±300mV,±500mV,±10V 1
158 320 Voltagemeasurement:±400V,±600V,±800V,±1000V,±1200V
158 338 Voltagemeasurement:±1400V,±1600V,±1800V,±2000V,±2200V,±3600V
159 807 Voltagemeasurement:0…1500V
163 981 Voltagemeasurement:±3600V,Measuringoutput:±10V
163 999 Voltagemeasurement:±3600V,Measuringoutput:±20mA
164 004 Voltagemeasurement:±3600V,Measuringoutput:4…20mA 1 Onlyoutput±10V
Camille BauerVoltage Transducers
11
SINEAX P530/Q531
Power transducers: Common features
To convert active or reactive power into a proportional DC signal.
Customer benefit• Determinationofthechronologicalprogressionofthepowerinput• Avoidanceofunderandoverloadsituations,loadcontrol• Monitoringofrotatingmachines• Monitoringforblockages,e.g.inconveyorfacilities• Monitoringofenergydistribution• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationThetransducersforactiveorreactivepowermaybeconnectedviacurrentandvoltagetransformers,butcanalsobeusedfordirectmeasurement.Theyprovideanoutputsignalinformofadirectcurrent signal which is proportional to the measured power. Depending on the application, versions formeasurementinsingle-phaseorthree-phasesystemswithbalancedorunbalancedloadsareavailable.Theinstrumentscanbeeasilysnappedontoatop-hatrail(35x15mmor35x7.5mm).
Stock variants
Special features P530 Q531 P200 P600
Measuredvariableactivepower • •
Measuredvariablereactivepower • •
Measuredvariablemixedcurrentpower •
Measuredvariabledirectcurrentpower •
Camille BauerPower Transducers
Transducer for active or reactive power
Tomeasuretheactivepower/reactivepowerofasingle-phase alternatingcurrentorathree-phasecurrent.
Customer benefit•Monitoringofpowerconsumptioninenergydistributionsystemsandprocessengineering•StandardasGL(GermanischerLloyd),suitableforships
Technical dataMeas.input: Single-phasealternatingcurrent,3-wirethree-phasecurrentwithbalanced/
unbalancedloadsor4-wirethree-phasecurrentwithbalanced(onlyP530)/unbalancedloads
NominalvoltageUn100…115V,200…230V,380…440V,600…690Vor100…690V
NominalcurrentIn1A,5Aorcustomised(1…6A) Maximumvalueofthemeasuringrange≥0.75to1.3·nominaloutput,unipolaror
bipolar Nominal frequency 50/60 Hz, sinusoidalMeas.range: P530:Maximumvalue≤0.75to1.3·nominaloutput,unipolarorbipolar Q531:Maximumvalue≤0.5to1.0·nominaloutput,unipolarorbipolarMeas. output: Maximum output value 1 mA, 2.5 mA, 5 mA, 10 mA, 20 mA, 10 V or customised1…20mAor1…10V Outputsignalunipolar,bipolarorlive-zero Settingtime<300msMeas. principle: TDM methodAccuracy: Class0.5at15…30°CPower supply: 24 – 60 V AC/DC, 85 – 230 V AC/DC, ≥85 – 230 V AC from measurement input or 24VAC/24–60VDC,connectiononthelow-voltagesideHxWxD: 69.1x70x112.5mm(single-phase) 69.1x105x112.5mm(3/4wirethree-phasecurrent)
Forsingle-phasesystem
For3/4-wirethree-phasesystem
12 SINEAX P200
SINEAX P600
Transducer for active or reactive power
Transducer for mixed current power
Camille BauerPower Transducers
Tomeasurethepowerofasingle-phasealternatingcurrentorathree-phasecurrent.
Customer benefit• Veryfastpowermeasurement,suitedtocontrolandprotect• Possibilityofadjustingthemaximumvalueofthemeasuringrangeonsite(viahyperterminal)• Canalsobeusedfor162⁄3-Hzsystems
Technical dataMeas.input: Inputvoltage5…300VAC(phase-neutral) Inputcurrent0.5…6A Nominal frequency 162⁄3, 50, 60 Hz Maximumvalueofthemeasuringrange0.3…2.0xPn,unipolarorbipolarSystemconfigurations: Single-phasealternatingcurrent 3/4-wirethree-phasecurrentwithbalanced/unbalancedloadMeas.output: Maximumoutputvalue0…1to0…20mAor0…1to0…10V Outputsignalunipolar,bipolarorlive-zeroSettingtime: T99(blockmodefilter):½,1,2,4,8orupto64systemcycles T63(exponentialmode):3…200ms T99(exponentialmode):4.6xT63Meas. principle: TDM methodAccuracy: Class 0.5 Powersupply: AC:115Vor230V±15%,45–65Hz DC: 20 – 135 VH x W x D: 125 x 70 x 126 mm
Acquisitionofpowercomponentsofamixedcurrent(currentwithDCandACportions).
Customer benefit• RMSvaluemeasurementuptocrestfactor2• Possibilityofadjustingthemaximumvalueofthemeasuringrangeonsite• Canalsobeusedfor400Hzsystems
Technical dataMeas.input: Inputvoltagebetween0…300mVand800Vor±150mVand±800V Inputcurrentdirect0…1mAand0…50mAor±1and±500mAor fromshunt0…300mVand0…3Vor±150mVand±3V NominalfrequencyDC/10…70…400Hz Maximumvaluesofthemeasuringrange0.75…1.5·Un·In,bipolarrangesalso
possibleMeas.output: Maximumoutputvalueselectable1…20mAor1…15V Outputsignalunipolar,bipolarorlive-zero Settingtime300ms Alsoavailablewith2galvaniclyisolatedoutputsMeas.method: Onlydirectcurrentpowermeasurement(ACfiltered)ormixedcurrentpower
measurement unfiltered or with an eliminated DC portion or AC measurement, pulse groups
Meas. principle: TDM methodAccuracy: Class 0.5Power supply: AC: 115 V or 230 V 50/60 Hz or DC: Un 24 – 110 VH x W x D: 130 x 70 x 126 mm
13SINEAX F534 Transducer for frequency
Camille BauerFrequency and Phase Angle
For the conversion of the frequency of a system into a proportional DC signal.
Customer benefit• Determinationoftheprogressionandstabilityofthefundamentalfrequencyofanelectricsystem• StandardasGL(GermanischerLloyd),suitableforships(onlySINEAXdesign)• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationFrequencyisanimportantcommandvariableofelectricsystemsorpowerdistributionsystems.Variations of the system frequency particularly occur in system overload or underload situations. They mustbeimmediatelyrecognisedinordertotakecountermeasuresintime.Frequencyfluctuationsimpairtheperformanceofconnectedmachinesdisproportionately.However,thiscanalsobeutilisedin drive engineering to improve start and speed characteristics e.g. in frequency converters where thefrequencyisemployedasacontrolvariable.Thefrequencyismeasuredviaazero-phasevoltageorvoltagebetweenphaseswhichcanbedirectly connected via a converter. The instrument is also suited to distorted voltages with dominant fundamentalwaves.Adirectcurrentsignalproportionaltothemeasuredfrequencyisavailableattheoutput.
Technical dataMeas.input: Inputnominalvoltage10…230Vor230…690VMeas.range: 45…50…55Hz,47…49…51Hz,47.5…50…52.5Hz,48…50…52Hz,
58…60…62Hz orcustomisedbetween10and1500HzMeas.output: Maximumoutputvalue0…20mA,4…20mA,0…10Vor
customisedinthe1…20mAor1…10Vrange Outputsignalunipolar,symmetricallybipolarorlive-zero Settingtimeselectable2,4,8or16cyclesoftheinputfrequencyAccuracy: Class0.2at15…30°CPowersupply: 24–60VAC/DCor85–230VAC/DC(alsointernallyfrommeasurementinput) 24VAC/24–60VDC,connectiononthelow-voltagesideHxWxD: 69.1x70x112.5mm(SINEAX),
assemblyontop-hatrail(35x15mmor35x7.5mm)
14 SINEAX F535
Camille BauerFrequency and Phase Angle
Transducer for frequency difference
Acquisitionofthefrequencydifferenceoftwosystemstobesynchronised.
Customer benefit• Determinationofthefrequencydifferenceasasynchronisationcontrolvariable• StandardasGL(GermanischerLloyd),suitableforships• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationVoltage,phaseandfrequencybalancearethebasicpreconditionstoenabletheparallelconnectionofgeneratorsononebusbar.Thefrequencydifferenceisdeterminedbythesimultaneousmeasurementofthevoltagesofthebusbarandthegeneratorunittobeenergised.Theinstrumentisalsosuitedtodistortedvoltageswith dominant fundamental waves. A direct current signal proportional to the measured frequency differenceisavailableattheoutput.
Technical dataMeas.input: Inputnominalvoltage10…230Vor230…690VMeas. range: fS=50Hz:fG=49.5…50…50.5Hz,fG=47.5…50…52.5Hz,
fG=47.5…50…52.5Hz,fG=40…50…60Hz,fS=60Hz: fG=57.5…60…62.5Hzorcustomisedbetween10and1500Hz
[fS=frequencybusbar,fG=frequencygenerator]Meas.output: Maximumoutputvalue0…20mA,4…20mA,0…10Vor
customisedinthe1…20mAor1…10V Outputsignalunipolar,symmetricallybipolarorlive-zero Settingtimeselectable2,4,8or16cyclesoftheinputfrequencyAccuracy: Class0.2at15…30°CPowersupply: 24–60VAC/DCor85–230VAC/DC(alsointernallyfrommeasurementinput) 24VAC/24–60VDC,connectiononthelow-voltagesideHxWxD: 69.1x70x112.5mm(SINEAX),
assemblyontop-hatrail(35x15mmor35x7.5mm)
15SINEAX G536
Camille BauerFrequency and Phase Angle
Transducer for phase angle or power factor
Acquisitionofthephaseangleorpowerfactorbetweenthecurrentand voltageofasingle-phasesystemorasymmetricallyloadedthree-phasesystem.
Customer benefit• Monitoringofthereactivepowerrequirementinenergydistributionsystemsandprocess
engineering• Determinationofcharacteristicvalueforreactivepowercompensation• StandardasGL(GermanischerLloyd),suitableforships• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationTheinstrumentservestheacquisitionoflosseswhicharecausedbynon-linearloadsorreactiveimpedances. During a day, these might strongly fluctuate which impedes static reactive power compensation since overcompensation is not permitted.Thetransducerforphaseangleorpowerfactorcanbeconnectedviacurrentandvoltagetransformerordirectly.Theinstrumentisalsosuitedtodistortedinputvariableswithdominantfundamental waves. At the output, a direct current signal proportional to the measured phase angle orpowerfactorbetweencurrentandvoltageisavailable.
Technical dataMeas.input: Single-phasealternatingcurrentsystemor3/4-wirethree-phasesystemofthesame
load Nominalvoltage100V,230V,400Vorcustomised10…690V Nominalcurrent1A,5Aorcustomised0.5…6A Nominalfrequency50/60Hzor10…400HzMeas.range: Phaseangle–60°…0°…+60°elorwithin–180°…0°…+180°elor powerfactor0.5…cap…0…ind…0.5or
within–1…ind…0…cap…1…ind…0…cap…–1 Measuringspan≥20°el,unambiguousindicationonlyupto–175°…0…+175°elMeas.output: Maximumoutputvalue0…20mA,4…20mA,0…10Vor
customisedinthe1…20mAor1…10Vrange Outputsignalunipolar,symmetricallybipolarorlive-zero Settingtimeselectable2,4,8or16cyclesoftheinputfrequencyAccuracy: Class0.5at15…30°CPowersupply: 24–60VAC/DCor85–230VAC/DC(alsointernallyfrommeasurementinput) 24VAC/24–60VDC,connectiononthelow-voltagesideHxWxD: 69.1x70x112.5mm(SINEAX),
assemblyontop-hatrail(35x15mmor35x7.5mm)
16 SINEAX G537
Camille BauerFrequency and Phase Angle
Transducer for phase angle difference
Acquisitionofthephaseangledifferenceoftwosystemstobesynchronised.
Customer benefit• Determinationofthephaseangledifferenceasasynchronisationcontrolvariable• StandardasGL(GermanischerLloyd),suitableforships• Outputsignaluseableforindication,registration,monitoringandcontrol• Safetybygalvanicisolationandshock-proofterminals(IP20)
ApplicationVoltage,phaseandfrequencybalancearethebasicpreconditionstoenabletheparallelconnectionofgeneratorsononebusbar.Thephaseangledifferenceisdeterminedbythesimultaneousmeasurementofthevoltageofthebusbarandthegeneratorunittobeenergised.Theinstrumentisalsosuitedtodistortedvoltageswith dominant fundamental waves. A direct current signal proportional to the measured phase angle differenceisavailableattheoutput.
Technical dataMeas.input: Inputnominalvoltage10…230Vor230…690V Nominalfrequency50Hz,60Hzorcustomised10…400HzMeas.range: –120°…0…120°elorcustomisedwithin–180°…0…180°el,
inwhichmeasuringspan≥20°el,unambiguousindicationonly upto–175°…0…+175°el
Meas.output: Maximumoutputvalue0…20mA,4…20mA,0…10Vor customisedinthe1…20mAor1…10Vrange
Outputsignalunipolar,symmetricallybipolarorlive-zero Settingtimeselectable2,4,8or16cyclesoftheinputfrequencyAccuracy: Class0.2at15…30°CPowersupply: 24–60VAC/DCor85–230VAC/DC(alsointernallyfrommeasurementinput) 24VAC/24–60VDC,connectiononthelow-voltagesideHxWxD: 69.1x70x112.5mm(SINEAX),
assemblyontop-hatrail(35x15mmor35x7.5mm)
17
Camille BauerMultifunctional Transducers
Content Multifunctional Transducers
Introduction ........................................................................................................................... 18
Overview ................................................................................................................................ 19
Multi-transducer M56xM561 / M562 / M563 .............................................................................................................. 20
Multi-transducer line DME4Overview ................................................................................................................................. 21
DME424/442 .......................................................................................................................... 22
DME401/DME440Modbus ....................................................................................................... 23
DME406ProfibusDP ............................................................................................................... 24
DME400LON .......................................................................................................................... 24
Universal measuring unit CAMCAM ....................................................................................................................................... 25
EDS-CAM ................................................................................................................................ 26
Accessories for transducer line DME4A200,displayunitfortransducerlineDME4 .............................................................................. 28
For19”assemblyrackEURAXBT901 ....................................................................................... 28
18
L1 L2 L3 N
P
Q
U
4…20 mA
4…20 mA
4…20 mA
P: 4…20 mA
Q: 4…20 mA
U: 4…20 mA
L1 L2 L3 N
IntroductionConventional transducers for heavy current variablesareanexcellentaidtoacquireindividualelectricvariablesinenergydistribu-tion, automation or process engineering and to process them in accordance with requirements. However,ifseveralvariablesaretobeacquired,microcontroller-basedmultifunctionalinstru-ments constitute the more effective and more cost-effectivesolution:
Less assembly and wire expenditure• Lesscopper• Lessinstallationtime• Reducedsusceptibilitytofailures
Flexibility • Severalmeasuredvariablesperinstrument• Lowerplanningcostsduetofewer
components• Adaptabletoapplicationbysoftware• Analysisandmonitoringoptions• Nofixedmeasuringranges• Hardlyanyhardwarevariants• Reducedstocks
Risk• Alloftheinformationislostinaninstrument
failure
Operating principle of sampling systems1. Measurement of the fundamental frequency of thesystem.Simplerinstrumentspresupposea constant system frequency which can lead to larger errors.
2.Samplingoftheinputvariablesofvoltageandcurrentofallphasesbasedonthemeasuredfundamental frequency. Quality criteria are the numberofsamplingoperationspersystemcycleandthereproducibleresolutionofthemeasuring system. The correct timing of the sampling process is also very important so thatunbalancesandphaseshiftingscanbe
Introduction
Camille BauerMultifunctional Transducers, Introduction
properly analysed.3. Calculation of the required measured variables,basedonthesamplingvalues.
4.Measuredvaluesaremadeavailabletotheprocess.TheymaybeanaloguevaluesforaPLC or an analogue indicator, states of a limit value monitoring system or digital measured valuesviaabusinterface.
5.Moreextensiveanalyses.ThepossibilitiesarelimitedbythecapacityoftheuCsystemused.CamilleBauermakesavailablesystemswithdifferent capacities.
ApplicationTheoppositetablehelpsintheselectionoftheinstrument family. This is an overview, details concerning individual instrument variants are containedinsubsequentpages.Multifunctionaltransducerscanbeconnectedvia current and voltage transformers or directly. AllCamilleBauerlinescanbeuseduniversally.Theapplication(systemconfiguration)aswellasnominal values of current and voltage are freely programmablewithoutanyhardwarevariants.Theallocationofmeasuredvariablestotheoutputs and the determination of the limits of the measuring ranges is also realised using the res-
Conventional transducers
Multifunctional transducers
pectivePCsoftwarewhichismadeavailablefreeofchargebyus.Servicefunctionssupport users during commissioning. In this way, e.g. values of analogue or digital outputs canbesimulatedtotestsubsequentcircuitswithoutthemeasurementinputhavingtobeconnected or activated.Instrumentvariantswithabusconnectionprovide all acquired measured values via the corresponding digital interface. The respective documentation is attached to the instrument orcanbedownloadedfromourhomepagehttp://www.camillebauer.com
AccessoriesFor configuration software see Page 60
19SINEAX M56x SINEAX DME4 SINEAX CAM
Camille BauerMultifunctional Transducers, Overview
Overview
Overview of the instrument families
Measuring system
Samplingvaluespersystemperiod 24 32 128(continuously)
Accuracy class0.5
Analogue outputs: 0.25Measuredvariablesofbus:0.2
Basicinstrument:0.2I/Omodules:0.1
Settingtime(at50Hz) ≥ 1.0s, depending on the system configuration and the selected
measuredvariables
≥ 0.3s, depending on the system configuration and the selected
measuredvariables≥ 0.06s
Nominal frequency 50/60 Hz 16.7 Hz, 50/60 Hz 45…65Hz,10…70Hz,10…140Hz
Nominal current 1…6A 1…6A 1…5A,Overridingupto10A
Nominal voltage 57.7…400V(Ph–N)100…693V(Ph–Ph)
57.7…400V(Ph–N)100…693V(Ph–Ph)
57…400V(Ph–N)100..693V(P–P)
Measured variables
Basicvariablesofthesystem1 • • •
Neutral wire current measurement •
Meters • •
Tariff switching for meters •
Unbalance •
THD, TDD, harmonics Up to the 50th harmonic
Maximum and minimum value with time stamp
•
Mean value acquisition •
Logger for measured value progression
Option
Alarm / event / operator lists Option
Display of measured values and lists,acknowledgementofalarms
Measuredvalues+meterswithaccessorySINEAXA200
Option(internalorexternal)
I/O interface fixed fixed modular(upto4modules)
Analogue outputs 1, 2 or 3 2 or 4 2 per module
Analogue inputs 2 per module
Digital outputs 4 or 2 3 per module
Digital inputs 3 per module
HV input 110/230 VAC 1 per module
Possiblebusconnections RS485(Modbus),Profibus,LON As a standard: RS485(Modbus)+USB
Option:EthernetIEC61850orModbus/TCP
Special software functions
Systemcheck • •
Checkofconnection •
Logic module •
1 Thebasicvariablesofthesystemareallsingleandsystemvariablesofvoltage,current,bimetalcurrent,active,reactiveandapparentpower,reactive and power factor as well as frequency
20
SINEAX M561/M562/M563
Tomeasureupto3selectablevariablesinaheavycurrentsystem.
Customer benefit• Onemeasurementunitforuptothreeheavycurrentvariables• Fullyprogrammable,thereforehardlyanyproductvariance.Reducedstocks• Ideallysuitedtomodernisingexistingplants• EMCresistancefarabovelegallystipulatedlimits• PCsoftwarewithpasswordprotectionforconfigurationandcommissioning• Outputsignal(s)useablefordisplay,registrationandmonitoring• Safetythroughgalvanicisolationofallcircuitsandshock-proofterminals
ApplicationTheinstrumentsoftheprogrammableM56xtransducerlinearedesignedformeasurementinelectricdistributionsystemsorindustrialplants.User-definedmeasuredvariablescanbeissuedviaupto3bipolar,galvaniclyisolatedanalogueoutputsandusedforon-sitedisplayortheconnectiontoasupervisorysystem(e.g.PLC).Theareaofinterestmaybehighlightedbythescalefunction.Themeasuringsystemofthetransducershasbeendesignedfortheacquisitionofsinusoidalalternatingcurrentsignalswithlowharmoniccontent.Contentsuptothe11thharmonicaretakenintoconsideration.Theseinstrumentsaresuitedtomeasureafterphase-anglecontrolsorfrequencyconvertersonlyinalimitedfashion.Forverydistortedsignalsorafterfull-wavecontrolstheuseofSINEAXCAMisrecommended.ThetransducerisconnectedviathePRKAB560programmingcabletotheRS232interfaceofthePC for programming. During commissioning, the output signals are simulated via PC software and measured values are retrieved and recorded.
Overview of instruments
Features M561 M562 M563
Numberofanalogueoutputs 1 2 3
Technical dataMeas.input: Nominalvoltage57.7…400V(Ph-N)or100…693V(Ph-Ph) Nominalcurrent1…6A,nominalfrequency50or60HzSystemconfiguration: Single-phasealternatingcurrent,3/4-wirethree-phasecurrentwithabalanced/
unbalancedload,alsoinreducedphase-shiftconnection(2voltages,1current)Meas.output: Maximumoutputvalue20mAorcustomised1…20mAor5…10V Outputsignalunipolar,bipolar,live-zero Transfercharacteristics:Invertible,with/withoutstep(scalefunction) Measuringcycletime0.6…1.6s,dependingonmeasuredvariable(s)and
programmingAccuracy: Class0.2(voltageandcurrent),Class0.5(othervariables) Applicationsinreducedphase-shiftconnection:doubleclassPowersupply: 24–60VAC/DCor85–230VAC/DC(alsointernallyfrommeasurementinput)HxWxD: 69.1x105x112.5mm,top-hatrailassembly
Stock variants
Article No. Type Power supply (external) Output signal
158 411 M561 with1 analogue output
24 – 60 V AC/DC
±20mA
158 429 85 – 230 V AC/DC
158 437 M562 with2 analogue output
24 – 60 V AC/DC
158 445 85 – 230 V AC/DC
146 458 M563 with3 analogue output
24 – 60 V AC/DC
146 440 85 – 230 V AC/DC AccessoriesForM560configurationsoftwareseePage60,forPRKAB560programmingcableseePage66
Programmable multi-transducers
Camille BauerMulti-Transducer M56x
21
Programmable multi-transducer line DME4
Toacquireseveralvariablesofanyheavycurrentsystemsimultaneously.
Customer benefit• Onlyonemeasuringunitforseveralheavycurrentvariables,Class0.2• Fullyprogrammable,thereforehardlyanyproductvariance.Reducedstocks• Upto693Vnominalvoltage(betweenphases)inCATIII• Integratedenergymeterswithprogrammablemeasuredvariable• PCsoftwarewithpasswordprotectionforconfigurationandcommissioning• Outputsignal(s)useablefordisplay,registration,meteringandmonitoring• Safetythroughgalvanicisolationofallcircuitsandshock-proofterminals(SINEAX)
Overview of instruments
Type DME442 DME424 DME406 DME400 DME401 DME440
Input 100…693V(Ph–Ph),1…6A,16.7/50/60Hz
Accuracy Analogueoutputs:0.25%,measuredvariablesofbus:0.2%
Analogue outputs 4bipolar [mAorV]
2bipolar [mAorV]
–– –– ––4bipolar [mAorV]
Digital outputs 2 4 –– –– –– ––
Meter up to 2 up to 4 4 4 4 4
Bus –– –– ProfibusDP LON Modbus Modbus
Camille BauerMulti-Transducer Line DME4
General applicationTheinstrumentsoftheprogrammableDME4transducerlinearedesignedformeasurementinelectricdistributionsystemsor industrial plants. They are used where ahighdegreeofaccuracyandflexibilityisdemanded. Depending on the instrument type,user-definedmeasuredvariablesareissued at analogue or digital outputs or all acquiredvariablesmaybepolledviathebus.
The measuring system of the transducers hasbeendesignedfortheacquisitionofsinusoidal alternating current signals with low harmonic content. Portions up to the 15thharmonicaretakenintoconsideration.These instruments are suited to measure afterphase-anglecontrols,forapplicationsafterfrequencyconverterstheycanonlybeused in a limited fashion . For very distorted signals or after zero crossing controls the use ofSINEAXCAMisrecommended.
For a comprehensive measured value display onsite,theSINEAXA200displayunitcanbeconnectedtotheserialRS232interfaceofthe converter in all instrument types of the DME4line.Inthisway,allinstantaneousormetervaluescanbedisplayed.
Thetransducerisconnectedviaa1:1cabletotheRS232interfaceofthePCforprogramming.Duringcommissioning,possibleoutputsignalscanbesimulatedviaPCsoftware.Thecomplete
Common technical dataMeas.input: Nominalvoltage57.7…400V(Ph-N)or100…693V(Ph-Ph),nominalcurrent
1…6A,nominalfrequency50,60or162⁄3 HzSystemconfiguration: Single-phasealternatingcurrent,3/4-wirethree-phasecurrentwithbalanced/
unbalancedloador3-wirethree-phasecurrentwithbalancedloadinreducedphase-shiftconnection(2voltages,1current)
Measurement output: Dependingoninstrumenttype,measuringcycletime0.13…0.99s,dependingon
instrument type and programmingAccuracy: Statevariablesviabusinterface:Class0.2,measuredvariablesatanalogueoutputs:
Class 0.25 Active power meters: Class 1, reactive power meters: Class 2 Applicationswithreducedphase-shiftconnection:doubleclassPower supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC or AC supply 100, 110, 230, 400, 500,
693VAC(onlyDME400,424,442),alsointernallyfrommeasuringinputHxWxD: 69.1x105x112.5mm,top-hatrailassembly(35x15mmor35x7.5mm)or plug-incardEuropeanformat,faceplatewidth14TE
(EURAXDME442,440)
AccessoriesForDME4configurationsoftwareseePage60ForRS232programmingcable(1:1connectioncable)seePage66For19”assemblyrackforEURAXplug-incardsseePage28ForSINEAXA200,displayunitfortheDME4lineseePage28
imageofthesystemmayberetrievedviatheRS232orapossiblebusinterfaceoftheinstrument,e.g.tocheckthecorrectconnection.
22
SINEAX DME424
SINEAX DME442
EURAX DME442
Camille BauerMulti-Transducer Line DME4
Programmable multi-transducer
Toacquireseveralvariablesofanyheavycurrentsystemsimultaneously.
For general data see„ProgrammabletransducerlineDME4“,Page21
Overview of instruments
Features DME424 DME442
Numberofanalogueoutputs 2 4
Numberofdigitaloutputs 4 2
ApplicationTheprogrammablemulti-transducersDME424/442canimageseveral,freelyprogrammablemeasuredvariablesatanalogueanddigitaloutputs.ThemeasuredvariablesareallocatedtotheoutputsbyDME4PCsoftware.Analogueoutputsmaybeusedforon-sitedisplayortheconnectiontoasupervisorysystem(e.g.PLC).Theareaofinterestmaybehighlightedbythescalefunction(step).Completesuppressionofthelowerorupperrangeisalsopossible.Digitaloutputsmaybeusedforthepulseoutputtoexternalmeters.Simultaneously,aninternalmeterreadingisbuiltwhichcanbereadviatheRS232interface.Digitaloutputsmayalsobeusedtomonitoroverrunsorshortfallsoflimitvalues.Inaddition,twooutputspermitlinking(AND/OR)ofupto3limitvalues.Duringcommissioning,theoutputsignalscanbesimulatedviaPCsoftwareinordertotestsubsequentcircuitsalsowithoutanactivatedinput.Ifdigitaloutputsareusedaslimitvalues,thestatecanbespecified,ifusedasapulseoutput,apercentageofthesetpulserate.
Technical dataAnalogue outputs• Maximumvalueoftheoutput20mAor customised1…20mAor1…10V
• Outputsignalunipolar,bipolar,live-zero• Transfercharacteristics:with/withoutstep(scalefunction)• Measuringcycletime0.13…0.47s,dependingonmeasured variable(s)andsystemconfiguration, settingtime1…2·measuringcycletime
• Accuracy0.25c.Factorc>1,ifcharacteristicwithastep or only parts of the input or output range are used.
If the maximum values of the output of the instruments do not agree with the desired application, theycanbereducedbysoftware(possibleadditionalerror).Themaximumvaluesmayalsobeadaptedbyhardwaretothedesiredvalueorrearrangedfromcurrenttovoltageoutput(orviceversa).Thisrequiresthatresistancesintheinstrumentarechangedandthatoutputsarerecalibratedusing the PC software.
Digital outputs• Opencollectoroutputs,8…40Vexternallysupplied• Outputcurrent10…27mA(ON)and2mA(OFF)• Ifusedaspulseoutput:Pulsedurationandinterpulse period≥100ms,suitabletoenergisemechanicalmeters. Thepulsedurationcannotbeprogrammed.Theaccuracyofthepulseoutputcorrespondstotheclassoftheinternalmeters(seegeneraldata).
Stock variants
Article No. Type Power supply (external) Output signals129 206
DME442230 V AC
±20mA129 214 85 – 230 V AC/DC142 175 24 – 60 V AC/DC
Variantsfornominalfrequency50/60Hz,withouttestprotocolwithbasicconfiguration
AccessoriesForaccessoriesoftheDME4transducerlineseePage21
Limit of the output range
OnlySINEAX
23
SINEAX DME401
SINEAX DME440
EURAX DME440
Camille BauerMulti-Transducer Line DME4
Programmable multi-transducer
AcquisitionofallvariablesofanyheavycurrentsystemwithModbusconnection.
For general datasee„ProgrammabletransducerlineDME4“,Page21
Overview of instruments
Features DME401 DME440
Numberofanalogueoutputs 0 4
Modbusconnection yes yes
Availablein19”rackversion no yes
Customer benefitTheprogrammableDME401/440multi-transducerscanacquireallmeasuredvariablesofanyheavycurrentsystem.Inaddition,fouruser-determinedmeasuredvariablescanbeoutputviaanalogueoutputsinDME440.DME4PCsoftwareisusedtoallocatethemeasuredvariablestotheanalogueoutputsofDME440aswellassettinginputparameters.Analogueoutputsmaybeusedforon-sitedisplayortheconnectiontoasupervisorysystem(e.g.PLC).Duringcommissioning,theoutputsignalscanbesimulatedviaPCsoftwarewhichfacilitatesacompletetestofsubsequentcircuits.
Technical dataAnalogue outputsSeeDME442,howevermeasuringcycletimesupto0.99sifallmeasuredvariablesofa4-wiresystemwithanunbalancedloadshallbepolledviaModbus
ModbusFunctions: Measured value acquisition and configuration of the converter, resetting of meters and slave pointersProtocol: ModbusRTUPhysics: RS-485,max.linelength1200m(4000ft)Baudrate: 1200,2400,9600BdNumberofparticipants: max.32(includingmaster)
ModbusModbusis‚only‘aprotocol,i.e.instructionswhichstatethesequenceofcharacterswhichmustbesentforadesiredfunctionandhowtherespectivereplyisstructured.Itcanthusbeusedforanytransmissionmedium,onprinciple.However,normallyanRS-485interfaceisemployedsinceitisprice-effectiveandpermitstheformationofabusstructurewithseveralparticipants.TheModbusprotocolisasinglemasterprotocol.Thismaster(usuallyaPCorPLC)controlsthecompletetransmissionandmonitorspossiblyoccurringtimeouts(noreplyfromtheaddresseddevice).Theconnecteddevicesmaysendtelegramsonlyifrequestedbythemaster.
Stock variants
Article No. Type Power supply (external) Output signals
138 372 DME440with4 analogue outputs
85 – 230 V AC/DC±20mA
142 183 24 – 60 V AC/DC
146 515 DME401withoutanalogue outputs
85 – 230 V AC/DC––
146 523 24 – 60 V AC/DC
Variantsfornominalfrequency50/60Hz,withouttestprotocolwithbasicconfiguration
AccessoriesForaccessoriesoftheDME4transducerlineseePage21
OnlySINEAX
24
SINEAX DME406
SINEAX DME400
Camille BauerMulti-Transducer Line DME4
Programmable multi-transducer
Acquisitionofallvariablesofanyheavycurrentsystemwith ProfibusDPconnection.
For general data see„ProgrammabletransducerlineDME4“,Page21
ApplicationSINEAXDME406isafreelyprogrammabletransducerwithaPROFIBUS-DPinterface.ProfibusDP-V0usedinDME406hasbeenoptimisedforfastdataexchangeonthefieldlevel.AlldataandinformationrequiredfortheinstallationofthedeviceisincludedintheProfibusCDwhichaccompa-nies each instrument.
Technical data (Profibus DP-V0)Busconnection: Screwconnectiononterminals15to21Transmissionrate: 9.6kBaud…12MBaudorautomaticrecognitionofthebaudrateMax.buslength: 100…1200m,dependingonthebaudrateandthecableusedInterface: RS485,galvaniclyisolated(500V)Configuration: ViaPConsiteorviabusmaster
Stock variants
Article No. Type Power supply (external)
146 911DME406
85 – 230 V AC/DC
146 896 24 – 60 V AC/DC
Variantsfornominalfrequency50/60Hz,withouttestprotocolwithbasicconfiguration
AccessoriesForaccessoriesoftheDME4transducerlineseePage21
Programmable transducer
AcquisitionofallvariablesofanyheavycurrentsystemwithLONconnection. For general data see„ProgrammabletransducerlineDME4“,Page21
ApplicationSINEAXDME400isafreelyprogrammabletransducerwithaLONWORKS® interface. Instruments withaLONinterfaceareprimarilyusedinbuildingautomation.
Technical data LONWORKS® interfaceNetworkprotocol: LONTALK®
Transmissionmedium: EchelonFTT-10Atransceiver,transformer-coupled, reversepolarityprotected,twistedtwo-wirecableTransmissionspeed: 78kBit/s
LON (Local Operating Network)LONisafieldbusdevelopedbyEchelonCorporationoftheUSaround1990.LONtechnologyfacili-tatestheneutralexchangeofinformationbetweenplantsanddevicesofdifferentmanufacturers.
Further instruments with a LON interfaceEMMOD205,extensionmoduleAline,seePage39A2000, multifunctional power transducer, see Page 33
AccessoriesForaccessoriesoftheDME4transducerlineseePage21
25
USB
Modbus
Rel 1 Rel 2 I1 I2 I3 IN U1 U2 U3 N
1 2 3 4
Camille BauerUniversal Measuring Unit CAM
Universal measuring unit for heavy current variables
For the comprehensive analysis of any heavy current system.
Customer benefit• Consistentmeasurement(withoutinterruption)• Suitedtostronglydistortedsystems,zerocrossingorphase-anglecontrols• I/Ointerfaceadaptabletoindividualrequirements• ConfigurationandmeasuredvalueacquisitionviaUSBandModbusinterface• Acquisitionofminimumandmaximumvalueswithtimestamp• Systemanalysis(harmonicsandunbalance)• Synchronisablereal-timeclockasatimebasisandoperatinghourcounter• Graphicdisplaywithfreelyarrangedmeasuredvaluedisplayandalarmhandling(option)• Loggerforlong-termrecordingofmeasuredvalueprogressions(option)• Protocollistsforevents,alarmsandsystemmessages(option)
ApplicationSINEAXCAMisdesignedformeasurementinelectricaldistributionsystemsorindustrialplants. Apart from the current system state, thepollutionbynon-linearloadsaswellasthe overall load of the power system can bedetermined.Consistentmeasurementguaranteesthatanysystemchangeisreliablyacquired and included in the measured data.
Theoptional7-languagegraphicdisplay(internal,externalorboth)isprovidedtovisualise measured data and list entries on site. Users can adapt the display of measured data almost freely to their requirements. If required, a preferred display or an automatic
Thehigh-performancemeasuringsystemmakesthedevicealsosuitableforstronglydistortedsystems,zerocrossingorphase-anglecontrols.
TheI/Ointerfacemaybearrangedasrequired.Up to 4 modules with different functionality maybeused.Theloggerpermitslong-termrecordings of measured value progressions, e.g. tomonitorthevariableloadoftransformersortofacilitate automatic meter readings. Lists record
definableevents,alarmsandsystemmessageschronologicallyforasubsequentanalysisofincidents in the power system.
sequenceofmeasuredvaluesmaybedefined.The selection of the measured value display, resettingofmetersorextremevaluesbutalsotheacknowledgementofalarmmaybearrangedviathekeypad.Theauthorisationtoexecutesuchfunctionscanbelimitedviaasafetysystem
integratedinthedevice.Ifthesystemhasbeenactivated, the user must first log in via the display.
Ethernet-communication•IEC61850•Modbus/TCP
I/O interface•analogI/Os•digitalI/Os
Logic moduleMonitoringand alarming
Lists + loggerRecording and Registration
Measuring input: 3 voltages, 4 currents•Consistentmeasuredvalueacquisition•Adjustabletomeasuringtask
Universal power supply100…230VAC/DC
or24…60VDC
2 Relay outputs•Consumptioncontrol•Alarm
Graphic displayMeasurement display,Alarm handling
Graphic display (external) Measurement display,Alarm handling
26
SINEAX CAM
LN LLN0
LN MMXU
LN MHAI
LN MMTR
LN MSTA
LN MSQI
LN GGIO
LN LPHD
LN MMXN
LN MHAN
Logical Device
Physical Device
Camille BauerUniversal Measuring Unit CAM
Universal measuring unit for heavy current variables
Flexible I/O interfaceI/Omodulescanbeassembledaccordingtoindividualneeds.Upto4moduleswithselectablefunctionalitymaybeused.Sixdifferenthardwaremodulesareavailable.
Analog outputs ±20 mA or 0/4…20 mA, 2 outputs per module• On-sitedisplayviaanalogdisplayunits• Heavy-currentmeasurementsforPLC
Analog inputs 0/4…20 mA, 2 inputs per module• Acquisitionofext.quantities,e.g.temperature• Automaticmeteringofinputquantity• Scalable,e.g.4…20mAto0…100°C,displayableongraphicdisplayandrequestableviainterface
Digital outputs S0, 12/24 VDC, 3 outputs per module (switchable to inputs)• Alarmingoutputofthelogicmodule• Statereporting• Pulseoutput(S0)toexternalcounter
Digital inputs, 3 inputs per module: 12/24 VDC (switchable to outputs)
Digital inputs, 3 inputs per module 48/125 VDC (only in position 4)•Acquisitionofexternalstateinformation•Triggerorreleasesignalforlogicmodule•Pulseinputformetering
HV-input, 110/230 VAC, 1 input per module (only in position 4)•Clocksynchronizationtosystemfrequency•Monitoringofvoltageavailability(ON/OFF)
Ethernet communication (option)Tobeabletoanalyzethehugeamountofmeasureddatainreal-time,atransmissionmediumwithhighbandwidthisnecessary.Ethernetprovidesthishighperformance.
Option 1: Ethernet, Modbus/TCP protocolModbus/TCPisacommonlyusedprotocolforaneasyaccesstoconfigurationormeasurementdata.Itissupportedbyalargenumberofvisualizationsoftwaretoolsandthusallowsafastimplementationofthedevice.NTP(NetworkTimeProtocol)issupportedfortimesynchronisationviaEthernet.
Option 2: Ethernet, IEC 61 850 protocolThecommunicationstandardIEC61850isthenewstandardforsubstationautomation.Eachpossibledeviceorsystemfunctionisstandardizedandmappedinsocalledlogicalnodes(LN’s).CAM provides the following logical nodes:
MMXU / MMXN: Instantaneous values of voltages, currents, frequency, powers and load factors as wellastheirmaximumandminimumvalues.MMXUisusedforasymmetrical3and4wiresystems,MMXNforsinglephaseandbalancedload3and4wiresystems.
MHAI / MHAN:Individualharmonicsforvoltagesandcurrents,THD(totalharmonicdistortion)andTDD(totaldemanddistortion)andtheirmaximumvalues.MHAIisusedforasymmetrical3and4wiresystems,MHANforsinglephaseandbalancedload3and4wiresystems.
MMTR:Activeandreactiveenergymetersforincomingandoutgoingpower.Oneinstanceforbothhigh and low tariff.
MSTA: Mean values of voltage, current, active, reactive and apparent power as well as their maxi-mumandminimumvaluesoninstantaneousvaluesbase.Allmeasuredwithinthesameinterval.These values are provided for each phase as well.
MSQI:Imbalanceofvoltagesandcurrents,calculatedinaccordancewithtwodifferentmethods.
GGIO:Mapstheinformationofassembledanaloganddigitalinputmodules.ForeachinputaninstanceofGGIOprocessesstateinformation,ameasuredquantityormeteringpulsesfromanexternal device.
Analog output module
27
EDS-CAM
Camille BauerUniversal Measuring Unit CAM
Universal measuring unit for heavy current variables
Data logger: Long-term recordings (option)Thedataloggerallowstoperformlong-termrecordingsofmeasurementprogressionsorloadprofi-les,e.g.tomonitorthevariableloadoftransformers,feedersortransmissionlines.Inadditiontotherecordingofmean-values,fluctuationsofinstantaneousvaluesmayberegisteredtorecognizeloadpeaksattheearliestpossiblemoment.Bymeansoftheautomaticalmeterreadingatimesynchronousreadingofthemetercontentsofalldevicesmaybeperformed,e.g.onaweekly,monthlyorthreemonthsbase.Thesevaluescanbestoredforanydesiredtime,thusallowdeterminingtheenergyconsumptionpertimeforbillingpurposes.
Lists: Logging of alarms and events(Option)Listsallowachronologicalrecordingofevents,alarmsandsystemmessages.Eachchangeofthesystemstateandeachaccesstothedevicecanthusbereproducedandanalyzedatalatertimeinacorrectsequence.Eachentryinthelistsistimestamped.
Logic module (standard):The module consists of up to 32 logic functions with 3 digital input states each. Limit values of measuredvariables,statesofdigitalinputs,statedefaultsviabusinterfaceorresultsofotherlogicfunctionscanbeusedasinputvariables.Typicalapplicationsarelimitvaluemonitoringofindividualvariables(e.g.overcurrentofaphase)orofcombinations(e.g.phasefailure).ExternalfunctionscanalsobemonitoredviatheI/Ointerface.Theresultsofthelogicfunctionswillthentriggeractions.Thismaybeanalarmviadigitaloutputsorrelaysbutalsoanentryinanalarmoreventlistortheindication of an alarm text on the graphic display.
Technical dataMeas.input: Nominalvoltageupto693V(Ph-Ph),nominalcurrentupto5A,overridings
programmable,nominalfrequency45…65Hz,10…70Hzor10…140Hz ThedeviceisalsoavailablewithcurrentinputsforRogowskicoilsSystemconfiguration: Single-phasealternatingcurrent,splitphase,3/4-wirethree-phasecurrentwith
balanced/unbalancedload,clockwiseandanti-clockwiserotatingsystemsEnergymeter: Activeenergyincoming+outgoing,reactiveenergyincoming+outgoing+inductive
+capacitiveformeasuredsystemaswellasmax.12metersforexternalvariables via digital or analogue inputs. All meters high and low tariff if tariff switching is activated
Accuracy: Voltageandcurrent0.1%,powerandvoltageunbalance0.2% Harmonics,THDandTDD0.5%,powerfactor±0.1°,frequency±0.01Hz ActiveenergyClass1(EN62053-21),reactiveenergyClass2(EN62053-23) Analogueinputs/outputs±0.1%Dimensions: 90x186x63mm,assemblyontop-hatrail(35x15mmor35x7.5mm)
Standard interfaces(forconfiguration,service,measuredvaluepolling)•Modbus/RTUconnection,max.32participants(incl.master),baudratenupto115.2kBd•USBconnection(USBmini-B,5-pole),protocolUSB2.0
Stock variants
Article No. Type Power supply (external) I/O interface
158 726SINEAXCAM 100 – 230 V AC/DC
Without
158 734 4 analogue outputs, unipolar
Variants for nominal frequency 50 Hz, without test protocol with basic configuration
Accessories
Article No. Description
157 968 GraphicdisplayEDS-CAM,forexternalcontrolpanelassembly
168 949 Connectingcable2mEDS-CAM<>CAM,otherlengthsuponrequest
163 189 InterfaceconverterUSB<>RS485(Modbus)
Part of the scope of deliveryForCB-ManagerconfigurationsoftwareseePage61ForCB-AnalyzeranalysissoftwareforloggerandlistsseePage61
28
SINEAX A200
EURAX BT901
SINEAX A200-HH
Camille BauerAccessories for Transducer Line DME4
Display unit for transducer line DME4
19” Assembly Rack
VisualisingofallmeasuredvariablesoftheDME4transducers.
Customer benefit• On-sitedisplayofallmeasurablevariablesofaDME4transducer• ResettingofmetersandslavepointerswithoutPCandsoftware• Replacementfornumerousanaloguedisplays• Typeofloadingas4quadrantdisplay• Alsoavailablewithtop-hatrailadapter• High-contrast,14mmLEDdisplay,goodreadabilityalsofromlargerdistances
ApplicationThedisplayunitpermitstheindicationofallmeasureddataofaDME4multi-transduceronsite.Thisisparticularlyinterestingforpurebusdevices(Modbus,Profibus,LON,Ethernet)sincethemeasuredvaluescanbecheckedinthiswayswithoutrequiringaspecialbusvisualisingtool.Inversionswithanalogue and digital outputs, this unit can also display all of those values which are not imaged at the outputs.
AssoonasanA200isconnectedtotheserialinterfaceofaDME4,thedisplaybeginsreadingoutmeasured values. The direct connection of the devices and the purely digital data transmission achievethehighdisplayaccuracyof0.1%(U,I)or0.2%(P,Q,S).
Twoversionsareavailabledependingonwhetherthedisplayunitisonlytobeusedduringinstallationorwhetheritissupposedtobefirmlyinstalledasacost-effectiveon-sitedisplay:TheSINEAXA200controlpanelinstallationdeviceandtheportableA200-HHversion.
Technical dataPowersupply: SINEAXA200:Widerangepowerunit20–265VAC/DC A200-HH:RechargeableLi-Ionbattery,
24…90hoperatingtimedependingondisplayintensityDimensions: SINEAXA200:96x96x46mm,assemblyontop-hatrailviaadapterispossible A200-HH:260x120x65mm
Stock variants
Article No. Type Power supply (external)
154 063 SINEAXA200 20 – 265 V AC/DC
154 972 A200-HHcomplete –
AccessoriesConnectingcableSub9-pinmale/male,ArticleNo.154071(inA200-HHincludedinthescopeofdelivery),seePage66Top-hatrailadapterforSINEAXA200,ArticleNo.154055
forplug-incardsinEuropeanformat.
Customer benefit• Solder,wire-wraporscrewterminals• Customisedcompletelyorpartlyassembledrack
Technical dataPower supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC
29
Content Displaying Power Meters
Overview ................................................................................................................................ 30
Displaying power meters, extendable by modulesA210/A220 ............................................................................................................................. 31
A230/A230s ............................................................................................................................ 32
Displaying power meters, „All in one“A2000 .................................................................................................................................... 33
APLUS ...................................................................................................................................... 34
Accessories for A210, A220, A230s, A230Overview ................................................................................................................................. 36
EMMOD201:RS232/RS485interface+datalogger .................................................................. 37
EMMOD202:2analogueoutputs .............................................................................................. 37
EMMOD203:Ethernetinterface+datalogger ........................................................................... 38
EMMOD204:Profibusinterface ................................................................................................. 39
EMMOD205:LONinterface ...................................................................................................... 39
EMMOD206:M-Businterface ................................................................................................... 40
Camille BauerDisplaying Power Meters
30
Overview
Camille BauerDisplaying Power Meters, Overview
The displaying power meters for heavy current variablesarecompletelyprogrammable,universal measuring units. They provide numerous measured values and permit the
A210/A220 A230s/A230Displayunit+optionalextensionmodule
A2000 APLUS
„Allinone“Measuring systemVoltage, current ±0.5% ±0.2% ±0.25% ±0.1%Apparent, active, reactive power ±1% ±0.5% ±0.5% ±0.2%Active/reactiveenergy(IEC62053) Class0.5S/2Measuring interval 200 ms 200 ms 200 ms 2…1024periodsUninterrupted measurement ✓
Nominalvoltage(max.)L-L 500(600)V 500(600)V 500(550)V 690(832)VNominalcurrent(max.) 1or5A(6A) 1or5A(6A) 1and5A(6A) 1and5A(7.5A)Measured variablesBasicvariablesofthesystem1) ✓ ✓ ✓ ✓
Mean values 1…60min 1…60min 1…60min 1s…60minMin/max values with time reference withEMMOD…203 withEMMOD…203 ✓ ✓
Harmonic analysis 2. to 15. 2. to 15. 2. to 50.Extendedreactivepoweranalysis ✓
Voltage phase angle ✓
Systemasymmetry U(4L) U+l(3L+4L)EnergymeterP/Q(HT/LT) System System System,phaseorHT/NT System,phase(reference)UniversalmeterviaI/Os ✓(max.7)Operatinghourcounter 3+1Monitoring functionsLimit values 2 2 2 up to 16Booleanlogic(logicmodule) 4 functionsRecording functions withEMMOD… withEMMOD… (option) (option)Loadprofile(meanvalues) 201/203 201/203 ✓ ✓
Min/max values per interval 203 max ✓
Events/alarm ✓
Accidentrecording(RMS) ✓(≥300msvalues) ✓(≥2periodvalues)Autom. meter readings ✓
Interfaces withEMMOD… withEMMOD…
Ethernet 203 203 COMServer ✓(option)ProfibusDP 204 204 ✓
Modbus 1.2…19.2kBd 1.2…19.2kBd 1.2…19.2kBd 2.4…115.2kBdLON 205 205 ✓
M-Bus 206 206 ✓
Inputs/outputs withEMMOD… withEMMOD…
Digital inputs 0, 1, 2 0, 1, 2 0, 1 1…7Digital outputs 2 2 0, 2 1…7Analogue outputs 0, 2 0, 2 2, 4 0, 4Relay 2 1, 3DisplayUser-definabledisplay ✓ ✓
Limit value status display 4LED’s+plaintextFrontWxH[mm] 96 x 96 / 144 x 144 96 x 96 / 144 x 144 144 x 144 96 x 96Installationdepth(withmodule) 46(65) 46(65) 59 105
1) All phase and system variables of voltage, current, active, reactive and apparent power, power factor as well as frequency
complete acquisition of the state of a heavy currentsystem.Asisthecaseinmulti-transducers, a sampling measuring principle isused(seeoverviewofmultifunctional
transducers).Thetableshownbelowisaselection guide for the right instrument.
31
SINEAX A210
SINEAX A220
SINEAX A210-HH
Multifunctional power meter with display
Forthecompleteacquisitionofthesystemstateofathree-phaseheavycurrentsystem.
Customer benefit• Allrelevantvariablesofaheavycurrentsystemwithonlyonedevice• Replacementfornumerousanaloguedisplays• LargeLEDdisplaywhichcanbereadfromadistance• 2digitaloutputsforalarmsoroutputtoexternalcountermechanism• Integratedactiveandreactivepowermeters,5intervaltimeseachforP,QandS• Functionalityextendablewithplug-inmodules(busconnection,logger,analogueoutputs)
ApplicationTheinstrumentsaredesignedformeasurementsinelectricaldistributionsystemorindustrialplants.Allparametersmaybesetviathedisplay.ConfigurationcanalsobeperformedusingA200plussoftwareifanEMMOD201(Modbus)orEMMOD203(Ethernet)extensionmodulehasbeentemporarilyorpermanentlypluggedintothebasicdevice.Thedigitaloutputscannotonlybeusedtodriveexternalcountersbutalsoforalarmingincaseoflimitviolations.If,forexample,themeasuredvariableofcurrentistestedforexceedingalimitvalue,the same is triggered as soon as at least one of the phase currents exceed the limit value. A limit valueontheneutralwirehelpstominimisetheriskthatanundersizedneutralwirecausesinsulationdamageorevenfires.AnextensionmodulemaybepluggedintoconnectsupervisorysystemsortonetworkdevicesviaModbus,Profibus,LONorEthernet.Formobileuse,A210isalsoavailableinahandheldversion.A210-HHwithdataloggerisprovidedinacaseincludingvoltagemeasuringcables,software,batteryandsystemadaptor.Alsoclip-oncurrenttransformersareavailable,ifrequired.
Technical dataMeas.input: Nominalvoltage500V(Ph–Ph),nominalcurrent1/5A,nominalfrequency50/60HzSystemconfiguration: Single-phasealternatingcurrent,3/4-wirethree-phasecurrentwithbalanced/
unbalancedloadDisplay: 3digits+sign,frequency4-digit,meter8-digitAccuracy: Voltageandcurrent±0.5%,power,powerfactor,energy±1.0% frequency±0.02Hz(absolute).AlldetailsrefertonominalvaluesPower supply: 100 – 230 V AC/DC or 24 – 60 V AC/DCDimensions: A210: 96 x 96 x 46 mm, A220: 144 x 144 x 46 mm Assemblyontop-hatrailwithadaptor(ArticleNo.154055)ispossible
Stock variants
Article No.A210
Article No.A220
Input Power supply Test protocol
Mounted extension module
149 783 152 546500 V / 5 A
100 – 230 V AC/DC without
without
150 300 152 554 24 – 60 V AC/DC
150 318 152 562500 V / 5 A
100 – 230 V AC/DCwith
150 326 152 570 24 – 60 V AC/DC
152 447 152 588500 V / 1 A
100 – 230 V AC/DCwithout
152 702 152 736 24 – 60 V AC/DC
152 710 152 752500 V / 1 A
100 – 230 V AC/DCwith
152 728 152 744 24 – 60 V AC/DC
159 451
500 V / 5 A 100 – 230 V AC/DC without
EMMOD201(Modbus)
159 469 EMMOD203(Ethernet)
158 635 158 643 EMMOD204(Profibus)
AccessoriesForextensionmoduleEMMOD20xseePages36-40For configuration software A200plus see Page 60ForinterfaceadaptercableRS232seePage66
Camille BauerDisplaying Power Meters, Extendable by Modules
32
SINEAX A230s
SINEAX A230
SINEAX A230-HH SINEAX A230E-HH
Multifunctional power meter with display
Completeacquisitionandanalysisofthesystemstateofathree-phaseheavycurrentsystem.
Customer benefit (inadditiontoA210/A220)• Systemcanbeanalysedinrelationtounbalanceofvoltages• DeterminationofindividualharmoniccontentsandTHD• 3differentmodesforspecificmeasuredvaluedisplay• Additionalmeanvaluesalsofornon-powervariablesincludingtrendanalysis
Application (seealsoA210/A220)Electricaldistributionsystemsandindustrialplantsareincreasinglysubjectedtonon-linearloadslikecomputersorelectronicallycontrolledmotors.Thismightleadtoprematurefuseblow-outs,overloadoftheneutralwireormalfunctionsofdevices.A230s/A230isabletodeterminethisadditionalload.The harmonics analysis assesses whether an active correction to improve the system quality is required.Specialconsiderationshouldbegiventothecurrentharmonicsofthe3rd,9thand15thorder which add up in the neutral wire. Usingthesystemunbalancetheloadofatransformermaybeanalysed.Ifthesameisunbalancedloaded under nominal load this will lead to compensating current and thus to additional heating. The consequencemaybedamagetotheinsulationoreventhedestructionofthetransformer.Formobileuse,A230sisavailableinahandheldversion.A230-HH(Modbus)orA230E-HH(Ethernet)isprovidedinacaseincludingavoltagemeasuringcable,software,batteryandsystemadaptor.
Technical dataMeas.input: Nominalvoltage500V(Ph–Ph),nominalcurrent1/5A,nominalfrequency50/60HzSystemconfiguration: Single-phasealternatingcurrent,3/4-wirethree-phasecurrentwithbalanced/
unbalancedload,alsoinAronoropen-YmeasuringcircuitavailableDisplay: 4digits+sign,meter8digit,displaymodeprogrammableAccuracy: Voltageandcurrent±0.2%,power,powerfactor,energy±0.5%,
frequency±0.02Hz(absolute).AlldetailsrefertonominalvaluesPower supply: 100 – 230 V AC/DC or 24 – 60 V AC/DCDimensions: A230s: 96 x 96 x 46 mm, A230: 144 x 144 x 46 mm
Assemblyontop-hatrailwithadaptor(ArticleNo.154055)ispossible
Stock variants
Article No.A230s
Article No.A230
Input Power supply Test protocol
Mounted extension module
154 782 152 942500 V / 5 A
100 – 230 V AC/DCwithout
without
154 766 152 926 24 – 60 V AC/DC
154 790 152 950500 V / 5 A
100 – 230 V AC/DCwith
154 774 152 934 24 – 60 V AC/DC
154 740 152 900500 V / 1 A
100 – 230 V AC/DCwithout
154 724 152 885 24 – 60 V AC/DC
154 758 152 918500 V / 1 A
100 – 230 V AC/DCwith
154 732 152 893 24 – 60 V AC/DC
161 472earth fault monitoring in unearthed 500 V IT system
24–60 V AC/DC without
159 477 152 968
500 V / 5 A 100 – 230 V AC/DC without
EMMOD201(Modbus)
158 657 155 649 EMMOD203(Ethernet)
158 669 158 651 EMMOD204(Profibus)
161 480 161472withEMMOD205(156647) without EMMOD205(LON)
AccessoriesForextensionmoduleEMMOD20xseePages36-40For configuration software A200plus see Page 60ForinterfaceadaptercableRS232seePage66
Camille BauerDisplaying Power Meters, Extendable by Modules
33A2000 Mobil-Set
SINEAX A2000 Multifunctional power transducer with display
Completeacquisitionandanalysisofthestateofathree-phaseheavycurrentsystem.
Customer benefit• Allrelevantvariablesofaheavycurrentsystemwithonlyonedevice• Measurementofharmonicsandharmonicdistortion• Determinationoftheneutralwirecurrent• Continuousmeasuredvaluerecordingforloadprofilesandstatisticalpurposes(option)• Faultrecorderwithfastrecordingofeventswithaprefaultevent(option)
ApplicationThe instrument serves the analysis of alternating current systems and is used where conventional instrumentscannotmeetthegrowingrequirementsindistributionsystems.Thisisparticularlythecase where apart from current, voltage and power also the harmonic distortion and harmonics are of importance.Furtherusagecomprisesapplicationsinwhichinstrumentsaretobereplacedsimultaneouslywithconventionalrecordersandfaultindicators.Combinedwithcurrentandvoltageconverters,thedevice measures the most important low and medium voltage facilities.Analogueoutputs,limitvaluesandinterfacesareavailabletomonitorandprocessthemeasuredvalues. The data storage variant records the chronological progression of up to 12 measured valuessimultaneouslyandsafeinrelationtoasystemfailure.Importantmeasuredvaluesmaybecontinuallyrecordedforlongperiodsoftimeor,alternatively,recordingistriggeredbyaneventforadetermined period of time.Inevent-controlledrecording,theprefaulteventleadingtotheeventcanalsoberecordedwiththesamespeed.Youthusgetaverygoodoverviewoftheprefaulteventleadingtotheevent.Theinstrumentthusmeetstherequirementsofafaultindicatorconsiderablybetterthanconventionalpaperrecorderswereeverabletodo.A2000isalsoavailableinamobile variant. The A2000 power instrumentisinstalledinastablecase,incl.alligatorclipsforvoltagemeasurementinputs,RS232interfaceandparameterisingandanalysingsoftwareMETRAwin10forA2000.Thereisalsospaceinthecasefortheoptionalclip-oncurrenttransformer.
Technical dataMeas.input: Nominalvoltage500V(Ph–Ph),nominalcurrent1+5A,
nominalfrequency40…70HzSystemconfiguration: 3/4-wirethree-phasecurrentwithbalanced/unbalancedloadalsoinAron
measuring circuitDisplay: 4digits+sign,meter9digitAccuracy: Voltageandcurrent±0.25%,power,energy±0.5%,powerfactor±0.02,
frequency±0.02Hz(absolute).AlldetailsrefertonominalvaluesPower supply: 230/115 V AC or 20 – 69 V AC / 20 – 72 V DC or 73 – 264 V AC / 73 – 276 V DC or
20 – 27 V AC, 20 – 36 V DCDimensions: Front 144 x 144 mm, installation depth 59.1 mm
Assemblyontop-hatrailpossiblewithadaptor
Stock variants
Article No. I/Os Interface Data logger
A2000-V001 2 analogue outputs
RS232+RS485without
A2000-V002 4 analogue, 2 pulse outputs,1 synchronised inputA2000-V003 with
A2000-V004 2 analogue, 2 pulse outputs,1 synchronised input
RS232+LONwithout
A2000-V005 2 pulse outputs, 1 synchronised input RS232+ProfibusDP
Allvariantsfor500V/1+5A,powersupply230/115VAC,withsoftware,withouttestprotocol
AccessoriesConfigurationsoftwareMETRAWin10/A2000(includedinthescopeofdelivery)COMServerRS232-USBinterfaceconverterZ501L
Gossen MetrawattDisplaying Power Meters, „All in one“
34
APLUSMultifunctional power meter with display
Camille BauerDisplaying Power Meters, „All in one“
Measurement, monitoring and power quality analysis in power systems.
Fields of applicationThe APLUS is a comprehensive instrument for the universal measurement, monitoring and power qualityanalysisinpowersystems.ThefocusisonhighestSwissqualityandmaximumcustomerbenefit.Thedeviceissuitedfortheapplicationinpowerdistribution,instronglydistortedindustrialenvironmentsandinbuildingautomation.Nominalvoltagesupto690Vcandirectlybeconnected.Theconnectionoftheprocessenvironmentmaybeperformedbymeansofthecommunicationinterface,viadigitalI/Osorviaanalogoutputs.
Possible applications in power systems
• Acquisitionandcontrolofthepresentsystemstate
• Monitoringoftheoperationalbehaviour
• Analysisofthepowerquality
• Determiningloadprofilesandenergydemandvalues
• Findingthevariationsofthesystemload
• Measurementbeforeandbehindfrequencyconverters
• Recordingofoperatingprocedures
Measurement of power quantities.
The APLUScanbeadaptedfastandeasilytothemeasurementtaskbymeansoftheCB-Managersoftware.Theuniversalmeasurementsystemofthedevicemaybeuseddirectlyforanysystem,fromsinglephaseupto4-wireunbalancednetworks,withouthardwaremodifications.Independentofmeasurementtaskandouterinfluencesalwaysthesamehighperformanceisachieved.
Themeasurementisperformedinallfourquadrantsandcanbe adapted to the system to monitor in an optimal way. The measurement time as well as the expected systemloadcanbeparameterized.
Logic module: Monitoring of operating behaviour.
Toeffectivelyprotectoperatingresourcesitmustbeassuredthatmultiplesystemquantitiesarewithintheirallowedrange.Thelogicmoduleoffersacomfortablefacilitytocombinemultiplelimitvaluesandtotriggerfurtheractionssuchasalarming,eventregistrationordisturbancerecording.
To monitor the operating time of specific loads up to three operating time counters are supported, whicharecontrolledbymeansoflimitvaluesordigitaloperatingfeedbacks.
Possible applications of the logic module are:
• Functionofprotectiverelays(e.g.over-current,phasefailureorimbalance)
• Changeoverofthepresentoperatingmode,suchaslocal/remote(day/night)operation
• Controllingtherecordingofalarms,eventsandacknowledgmentprocedures
• Monitoringofexternaldevices:circuitstatesorselfmonitoringsignals
Power quality analysis instead of failure analysis.
Butwhat’sreallyneededwhenmonitoringpowerqualityisastatementiftheusedoperatingresourceswillworkundisturbedundertherealexistingconditions.
The APLUSthereforedoesnotworkwithstatistics,butexaminestherealenvironment,toallowperforming a corresponding immunity analysis.
• Variationofthesystemload
• Systemimbalance
• Additionalloadbyharmonics
• Violationsoflimitvalues
• Fundamentalanddistortionreactivepower
35
Multifunctional power meter with display
Camille BauerDisplaying Power Meters, „All in one“
The display
The APLUS offers all which is requested from a device with display:
• Excellentlegibilityfromalmostanydistanceandeachangle• Clearandexplicitdisplayofmeasureddata• Freecompositionofmeasurementdisplays• FreeallocationofalarmstostatusLED’s• Freedefinableplaintextdisplayforalarming• Preferencedisplayandrollmode
Free composition of the required functionsThe APLUSbasicunitisalreadycomprehensivelyequippedwitharelayoutputforalarming,adigitaloutput, e.g. for pulse output, and a digital input, e.g. for tariff switching.Forapplicationswherethisisnotsufficient,theoptionalI/Oextensions1or2areavailable:
•I/Oextension1:2relays,4x±20mA(galvanicallyisolated),2digitalI/O’s12/24VDC•I/Oextension2:2relays,6digitalI/O’s12/24VDC
ThedigitalI/OsoftheI/Oextensionscanbeconfiguredindividuallyasinputsoroutputs.
Parametrization, service and measurement acquisitionThesefunctionsarefacilitatedbytheincludedCB-Managersoftware.Asecuritysystemcanbeactivatedtorestricttheaccesstodevicedata.Thiswaye.g.changingalimitvalueviadisplaycanbelocked,butasettingviaconfigurationcouldstillbepossible.
AModbus/RTUinterface(RS-485)oranoptionalEthernetinterfacewithModbus/TCPprotocolareavailableforcommunication.
Data logger (option)Theoptionaldataloggercanbeusedforthenon-volatilestorageofmeasuredvalueprogressions(e.g.loadprofiles),events,alarms,meterreadingsanddisturbancerecordings.TheSDcardusedforstoragemaybereplacedon-site.ForatabularorgraphicalanalysisoftherecordeddatatheCB-Analyzersoftwareisavailable.
Technical data
Measuringinput:Nominalvoltageupto693V(PH-Ph),nominalcurrentupto5A, overrideupto7.5Aprogrammable,nominalfrequency50/60HzSystems: Single-lineAC,splitphase,3/4wirerotarycurrentbalanced/ unbalancedload,rotatingclockwiseandcounter-clockwise
Energymeter: Activeenergyincoming+outgoing,reactiveenergyincoming+ outgoing+inductive+capacitiveformeasuredsystemaswellas incoming active and reactive energy per phase, max. 7 meters forexternalvariablesviadigitalinputs.Highandlowtariffforall meters, if tariff switching is active.
Accuracy: Voltageandcurrent0.1%,powerandvoltageasymmetry0.2% harmonics,THDandTDD0.5%,powerfactor±0.1°,frequency±0.01Hz ActiveenergyClass0.5S(EN62053-22),reactiveenergyClass2(EN62053-23) Analogueoutputs±0.2%
Dimensions: 96 x 96 x 105 mm
Accessories
Article No. Description
163 189 InterfaceconverterUSB<>RS485
Part of the scope of deliveryForCB-ManagerconfigurationsoftwareseePage61ForCB-AnalyzeranalysissoftwareforloggerandlistsseePage61
36
Overview
Camille BauerAccessories for A210, A220, A230s, A230
TheextensionmodulesenlargethefunctionalityoftheA210,A220,A230sandA230powermonitors.Theycanbesimplysnapedontothebackofthebasicinstrumentandtaketheirpowersupplyfromit.
Functionality EMMOD... 201 202 203 204 205
typ A
205
typE
206
Interface
•RS232/RS485(Modbus/RTU) •
•Ethernet(Modbus/TCP) •
•ProfibusDP(RS485) •
•LON(communicationwithU160x) •
•LON(standard) •
•M-Bus •
Data logger
•Mean-values ≤ 2 ≤ 14
•Min/maxintervalvalues(A230s/A230only) ≤ 9
•TimereferenceviaPCtime •
•Timereferenceviabuilt-inRTC •
Outputs
•Analogoutputs0/4..20mA 2
•Digitaloutput125VDC 1
Digital inputs
•Synchronizationpulseformean-values 1
•TariffswitchingHT/LT 1
•SynchronizationorHT/LT 1 1 1
Parametrization of the module
•viasoftwareA200plus •
•viabasicdevice • • • •
•viaGSDinthecontrolsystem •
•viasoftwareA200plusandbrowser •
AlldevicesoftheAseries(A210,A220,A230s,A230)canbeequippedwithanadapterformountingontop-hatrail.Ifthebasicdeviceisalsoequip-pedwithanextensionmodule,inadditionasetwithlongerfixingclipsisrequired,toallowthefixingofthetop-hatrailadapter.
Accessories
Top-hatrailadapterforA210,A220,A230s,A230,ArticleNo.154055Fixingclipsasset(4pieces)fortop-hatrailadapterwithextensionmodule,ArticleNo.154394
37
EMMOD201
EMMOD202
Extension module Modbus, data logger, synchronised input
For power instruments A210, A220, A230s, A230.
Customer benefit• SwitchableinterfaceRS232/RS485(Modbus)forconfigurationandmeasuredvaluedisplay• Networkingofupto32devicesviaRS485• Digitalinputfortariffswitchingorexternalsynchronisationofbillingintervals• Loadprofilestorage:For15minmeanvalues,recordingupto166days• Dataloggerforprogressionofmeanvalues(onlywithA230andA230s)
ApplicationTheEMMOD201extensionmoduleissimplysnappedontothebackoftheA210,A220,A230orA230spowerinstrumentandissuppliedwithpowerbythesame.Parameterisingiscompletelyperformed via the A200plus PC software.
Technical dataConnections: PluggablescrewterminalsDatalogger: 16’000meanvalues,upto166days(1meanvaluewith15minintervals) A210/A220:Activepowermeanvalueinput-output,reactivepowermeanvalue
inductive+capacitive A230s/A230: Active power mean value input/output, reactive power mean value inductive/capacitive or input/output, apparent power mean value, up to 9 further meanvaluesfreelyselectable
Article No. Description
150 285 ExtensionmoduleEMMOD201
Forretrofitting.Formountedversionseetherespectivebasicinstrument.
Camille BauerAccessories for A210, A220, A230s, A230
Extension module 2 analogue outputs
For power instruments A210, A220, A230s, A230.
Customer benefit• 2analogueoutputs,e.g.fortheconnectiontoaPLC
ApplicationTheEMMOD202extensionmoduleissimplysnappedontothebackoftheA210,A220,A230orA230spowerinstrumentandissuppliedwithpowerbythesame.Theanalogueoutputsareprogrammedviathekeysonthedevice.
Technical dataNumberofchannels:2,galvaniclyisolatedOutput: 0…20mA,4…20mA,invertibleConnections: PluggablescrewterminalsLimitation: 0/3.7 mA or 21 mALoad voltage: 8 VAccuracy: ±0.1%(withoutA2xx)Measuredvariables: A210/A220:U,I,Iavg,In,P,Q,S,F,PF
A230s/A230: Additional voltage and current mean value, zero shift voltage, unbalancefactor,THDU,THDI
Article No. Description
155 574 ExtensionmoduleEMMOD202
For retrofitting.
38
EMMOD203Extension module Ethernet, data logger, real-time clock
For power instruments A210, A220, A230s, A230.
Customer benefit• FastcommunicationviaEthernet(IntranetorInternet)• MeasureddataviaModbus/TCPaccessible• Browserinterfaceforsystemparameterisingandmeasuredvalueacquisition• Dataloggerwithsynchronisabletimereference• 2digitalinputsforsynchronisedpulseandtariffswitching• Deviceinstallation,deviceconfiguration,measuredvaluedisplay,graphicloggeranalysisusingPC
software A200plus
ApplicationTheEMMOD203extensionmoduleissimplysnappedontothebackoftheA210,A220,A230orA230spowerinstrumentandissuppliedwithpowerbythesame.Themodulemayberetrofittedwithoutinterferencewiththebasicdevice.TheEMMOD203modulesupplementsthefunctionalityofthebasicA2xxdevicebyanEthernetinterface,adataloggeraswellasareal-timeclockasatimereference.ItfacilitatestheexchangeofdatawithacontrolsystemviaModbus/TCPandHTTP.Thedataloggerpermitsthenon-volatilestorageofprogressionsofmeanvaluesandmin/maxvalues(RMS)duringtheaveragingintervalwithatimestamp.Thesameenablesloadprofilerecordswhicharesynchronisedwiththebillingintervaloftheenergyprovider.Thereferenceisnotlostinapowerfailure.ThisiscontrarytoEMMOD201wherethetimereferencefortheacquiredvaluesissubse-quently related to the current PC time. EMMOD203isequippedwith2digitalinputswhichmaybeusedfortariffswitching(high/lowtariff)andforthesynchronisationofthereal-timeclockwiththesystemfrequencyorasastandardisedcontrol signal. TheA200plussoftwareandanetwork-compatiblePCarerequiredfortheconfigurationofthebasicA2xxdevice.Certainparametersofthenetworksettingsbutalsothesourceforthesynchronisationofthereal-timeclockaresetviathebrowserinterfaceofEMMOD203.
Technical dataConnectionsEthernet: 10/100BaseTx,RJ45-PortSynchronisedinput: 5V…300VAC,1…500Hz,pluggablescrewterminalsTariffswitching: 5V…300VAC/DC,pluggablescrewterminalsData loggerStoragedepth: max.37’500meanvalues,upto390days(1meanvaluewith15minintervals)Format: Binary(ASN.1BER)Measuredvariables: A210/A220:Activepowermeanvalueinput-output,reactivepowermeanvalue
inductive+capacitive A230s/A230: Active power mean value input/output, reactive power mean value inductive/capacitive or input/output, apparent power mean value, upto9furthermeanvaluesfreelyselectable,upto9min/maxvalues(RMS)within the averaging interval
Real-time clockBuffering withBattery,powerreserve2yearsSynchronisation ViathenetworkwithTIMEP(RFC738)orSNTP(RFC2030),
synchronisedinputonthesystemfrequency(50/60Hz)oranexternalripplecontrolsignal.ConfigurationviaWEBpage.
Article No. Description
155 582 ExtensionmoduleEMMOD203
Forretrofitting.Formountedversionseetherespectivebasicinstrument.
Further instruments with an Ethernet interfaceAPLUSwithEthernetinterfaceoption,seePage34SINEAXCAMwithModbus/TCPorIEC61850,seePage26A2000withCOMServer,multifunctionalpowertransducerwithdisplay,seePage33
Camille BauerAccessories for A210, A220, A230s, A230
39
EMMOD204
EMMOD205
Extension module Profibus DP
Camille BauerAccessories for A210, A220, A230s, A230
For power instruments A210, A220, A230s, A230.
Customer benefit• Cyclictransmissionofthedesiredprocessimageorsystemstate• Simpleandfastcommissioning
ApplicationTheEMMOD204extensionmoduleissimplysnappedontothebackoftheA210,A220,A230orA230spowerinstrumentandissuppliedwithpowerbythesame.ParameterisingusesGSD.Allinstrumentparameterscanbeengineeredinthecontrolsystem.Onsite, only the slave address is set. Required measured data is determined during engineering and arrangedasafixedprocessimage(upto34measuredvaluemodules).Allinstantaneousvaluesaswellasmeterreadingsareavailableasmeasuredvariablesforselection.Aftertheacquisitionoftheconfiguration, the device transfers the process image cyclicly to the control system.
Technical dataConnection: 9-pinD-subsocket,EIARS485standard,15kVESDprotectionType: DPV0,SPC4-2.Baudrateautomaticor9600bit/sto12Mbit/s
Article No. Description
158 510 ExtensionmoduleEMMOD204
Forretrofitting.Formountedversionseetherespectivebasicinstrument.
Further devices with Profibus DP interfaceForDME406,programmablemulti-transducerwithProfibus-DPinterface,seePage24For A2000, multifunctional power transducers with display, see Page 33
Extension module LON
For power instruments A210, A220, A230s, A230.
Customer benefit• InstantaneousvaluesandmeterreadingscanbeacquiredviaLONTALKprotocol• DirectconnectiontotheU160xsummatorofGossen-Metrawattispossible
ApplicationTheEMMOD205extensionmoduleissimplysnappedontothebackoftheA210,A220,A230orA230spowerinstrumentandissuppliedwithpowerbythesame.Thebasicinstrumentsare parameterisedviakeysonthedevice.Alternatively,EMMOD201orEMMOD203canbesnappedonfirstofalltoenableprogrammingviaaPCandsubsequentlyachangetoEMMOD205ismade.
Technical data LONWORKS®InterfaceNetworkprotocol: LONTALK®Transmissionmedium: EchelonFTT-10ATransceiver,transformer-coupled,reversepolarity
protected,twistedtwo-wirecableTransmissionspeed: 78kBit/sConnections: Pluggablescrewterminals
Article No. Description
156 639 ExtensionmoduleEMMOD205withsynchronousinput
156 647 ExtensionmoduleEMMOD205withdigitaloutput125V, connection to U160x of Gossen-Metrawattpossible
Forretrofitting.Formountedversionseetherespectivebasicinstrument.
Further instruments with a LON interfaceDME400,programmablemulti-transducerwithLONinterface,seePage24A2000, multifunctional power transducer, see Page 33
40
EMMOD206
For power instruments A210, A220, A230s, A230.
Customer benefit• InformationonenergyconsumptionandinstantaneousvaluesviaM-Busprotocol• Digitalinputfortarifswitchingorexternalsynchronisationofbillingintervals
ApplicationTheEMMOD206extensionmoduleissimplypluggedontothebackoftheA210,A220,A230orA230spowerinstrumentandsuppliedbythesame.ThebasicinstrumentscanbeparameterisedviakeysatthedeviceitselforviatheM-Bus.
Available measured valuesThemeasureddatatobetranferredintheM-Busprotocolmaybecombinedfromthefollowingmeasuredvariables:– Active energy meter incoming / outgoing– Reactive energy meter incoming / outgoing or inductive / capacitive– Mean power values incoming active power and incoming reactive power– Instantaneous values voltage, current, power, power factor and frequency
Technical dataSystemprotocol: M-BusaccordingtoEN13757Transmissionmedium: M-BusaccordingtoEN13757Transmissionrate: 300baudupto38.2kbaudConnections: Pluggablescrewterminals
Article No. Description
168 965 ExtensionmoduleEMMOD206
For retrofitting.
Further instruments with M-Bus interfaceU128x and U138x – active energy meter, see Page 43
Extension module M-Bus
Camille BauerAccessories for A210, A220, A230s, A230
41
Content Energy Management
Gossen MetrawattEnergy Management
Energy metersOverview ................................................................................................................................. 42
U1281 .................................................................................................................................... 43
U1381 .................................................................................................................................... 43
U1387 .................................................................................................................................... 43
U1289 .................................................................................................................................... 43
U1389 .................................................................................................................................... 43
U398A .................................................................................................................................... 45
U398B .................................................................................................................................... 45
ECS Energy Control SystemOverview ................................................................................................................................. 46
SummatorsOverviewsummators ................................................................................................................ 47
U1600 .................................................................................................................................... 48
U1601 .................................................................................................................................... 49
U1602 .................................................................................................................................... 50
U1603 .................................................................................................................................... 51
OverviewECSwithSMARTCONTROL ........................................................................................ 52
U200,SMARTCONTROLECS .................................................................................................... 53
Additional components for summatorsAdditional components ............................................................................................................. 55
Load optimisationU1500 .................................................................................................................................... 56
Power qualityMavolog 10 ............................................................................................................................. 57
Mavosys 10 ............................................................................................................................. 58
Software for energy managementZ302B,Z302C,Z302B ............................................................................................................. 62
ECSwin,configurationsoftwareforU160xsummator ................................................................. 62
ECSopt,loadoptimisingmoduleforECSwin ............................................................................... 63
U1600Excel-Makro ................................................................................................................. 63
EMC,energymanagementwithsystem ..................................................................................... 64
EncoreSeries .......................................................................................................................... 65
42
Overview energy meters
Gossen MetrawattEnergy Meters
Description Article No./characteristic
Active energy meter for 2-wire system, direct, class 1 U1281Active energy meter for 4-wire system, direct, any load, class 1 U389A U1289Active energy meter for 2-wire system, transformer, class 1 U1381Active energy meter for 3-wire system, transformer, any load, class 1 U1387Active energy meter for 4-wire system, transformer, any load, class 1 U389B U1389System frequency 50 Hz • • F0 F0 F0 F0 F0
60 Hz – – F1 F1 F1 F1 F1External voltage supply 24 V DC without – – H0 H0 H0 H0 H0
with – – H1 H1 H1 H1 H1Multifunctional design with additional measurementof U, I, P, Q, S, PF, f
without – – M0 M0 M0 M0 M0with – – M1 M1 M1 M1 M1
Design value of input voltage Ur 100 – 110 V P–P – – – – – U3 U3230 V P–N – – U5 – U5 – –400 V P–P • • – U6 – U6 U6500 V P–P – – – – – U7 –
Calibration without • • P0 P0 P0 P0 P0ApprovalD,calibration – – P1 P1 P1 P1 P1ApprovalD,calibrationandcalibrationcertificate
– – P2 P2 P2 P2 P2
Approval CH P3 P3 P3 P3 P3Approval AT – – – P4 – P4 P4ApprovalCZ P5 P5 P5 P5 P5Englishtypeplate – – P6 P6 P6 P6 P6Approval HR P7 P7 P7 P7 P7
Pulse output – – V0 V0 V0 V0 V0S0,1000pulses/kWh,calibratable S0-Standard – • V1 V1 V1 V1 V1S0,100pulses/kWh S0-Standard • – – – – – –S0,rate,durationprogrammable S0programmable – – V2 V2 V2 V2 V2Switchingoutputupto230V,1000pulses/kWh,calibratable(notH1) Pulse230VStandard – – V3 V3 V3 V3 V3Switchingoutputupto230V,rate,durationprogrammable(notH1) Pulse230Vprogrammable – – V4 V4 V4 V4 V4Bus connection without • • W0 W0 W0 W0 W0
LON – – W1 W1 W1 W1 W1M-Bus – – W2 W2 W2 W2 W2L-Bus – – W3 W3 W3 W3 W3
Transformer ratiosCurrent/voltagefixed,maindisplaycalibratable CT=VT=1 – • – – Q0 Q0 Q0Current/voltageprogrammable,secondarydisplaycalibratable CT,VTprogrammable – – – – Q1 Q1 Q1Current/voltage firmly set, main display calibratableCT=1…10000,VT=1…1000,CTxVT≤1Mio.
CT, VT fixed – – – – Q9 Q9 Q9
Overview of design approvals for billingCountry Authority Approval No. U1281 U1289 U1381 U1387 U1389
D PTB PhysikalischTechnischeBundesanstalt 20.15 04.27 • • • • •
A BEV BundesamtfürEich-undVermessungswesen OE05E040 •
OE05E050 • •
CH metas metrologieundakkreditierungschweiz EC206570-00 • • • • •
CZ CMI CeskyMetrologickyInstitut TEU221/04-4127 • • • • •
HR DZNM CroatianStateOfficeforStandardizationandMetrology HRF-6-1057 • • • • •
Obligatory calibration for energy metersEnergymetersincommercialorofficialusearesubjecttoobligatorycalibration.Thelegalbasisisthecalibrationacttoprotectconsumers.Itgovernstheapprovalandcalibrationobligationofinstrumentsandisalwaystobeadheredtoiftheacquisitionofelectricenergyisthebasisforenergycostbillingtothirdparties.In-housecostdistributionisexcluded.
Meter and calibration from the same sourceGossen-Metrawatthasastate-registeredtestoffice for electric instruments and can supply energymetersandcalibrationforGermanyfromthe same source.
Calibration sign
43
U1281, U1381
U1387
U1289, U1389
L-Bus
Electric energy meter with power display
Gossen MetrawattEnergy Meters
Acquisitionofactiveenergyin4-wirethree-phasesystems accordingtoEN61036.
Customer benefit• PreciseactiveenergymeasurementaccordingtoEN61036,class1• Calibrationcapability,suitedtoofficialbilling• Displayofinstantaneouspower• Extendableforadditionalsystemmeasurementvariables• Directconnection5(65)A,withoutadditionalcurrenttransformers• Transformerconnection5//1A• Transformerratioscanbesetandcalibrated• Variantfor60Hzsystemfrequencyavailable• Displayofinstallationerrorswithoutadditionalmeasuringequipment• PulseoutputS0or230V• Adjustablepulserateandpulseduration• Compactdesignrequireslittlespace• OptionalLON,M-bus,L-businterface• Optionalreadingwhileelectricalcircuitisswitchedoff
ApplicationTheenergymetersmaybeuniversallyusedfortheacquisitionandbillingofelectricalenergyintrade,household,industryandbuildingmanagementapplications.Momentarycircuitloadscanbeevaluated at any time using the additional instantaneous power display. Variants for direct connection (U1281,U1289)aredesignedforcurrentsupto65Awithouttheinstallationofadditionalcurrenttransformers.Thevariantsfortransformerconnection(U1381,U1387,U1389)maybeconnectedbothtox/1Aandx/5Acurrenttransformers.
Integrated error recognitionforincorrectrotaryfielddirection,missingphases,reverse-poledcurrenttransformers,measuringrangeoverloadsandmissingbusconnectionssavesvaluabletimeandtestequipmentduringtroubleshooting.
More transparency in operationInadditiontoactiveenergyandinstantaneouspower,themultifunctionalvariant(M1)alsodisplaysindividual currents, voltages, active, reactive and apparent power, power factors and frequencybysimplypressingakey.Voltagelevel,phaseutilization,reactivepowercomponentandcompensationcanthusbecontinuouslyevaluatedduringoperation.
Universal bus connectionTheenergymeterstransmitmeterreadingsandotherdatatodatalogging,billingandoptimizingsystems,aswellasbuildingautomationandcontroltechnologyapplications,viaoptionalinterfaces.• LONinterfacewithFTT-10Atransceiver(W1)•M-Bus interface according to EN1434-3(W2)• L-Bus interfaceforbattery-operatedHYDRO-RADIO868radiomodule(W3)
Diverse calibration capability – approval for official billingTheenergymeterscanbesuppliedascalibratedvariants(P1),andadditionallywithcalibrationcertificate(P2),forofficialenergybilling.Accordingtolegalrequirements,thecalibrationcertificatemay not show any deviation in measurement. Depending upon requirements, the following variants arepossible• Calibrated main display for primary energy, calibratedpulseoutputwithreferencetoprimaryenergyandafixedpulserateof1000pulses/kWh(V1,V3)–directlymeasuringvariant
• Calibrated main display for primary energy, transformerratiosstateduponorderingarefixed(Q9)andcalibrated,calibratedpulseoutputwithreferencetoprimaryenergyandafixedpulseratedependingonCTxVT(V1,V3)
• Calibrated main display for secondary energy, fixedtransformerratiosCT=VT=1(Q0),calibratedpulseoutputwithreferencetosecondaryenergyandafixedpulserateof1000pulses/kWh (V1,V3)
• Uncalibrated main display for primary energy, adjustabletransformerratios(Q1)incombinationwithacalibratedancillarydisplayforsecondaryenergy,calibratedpulseoutputwithreferencetosecondaryenergyandafixedpulserateof1000pulses/kWh(V1,V3)
Alternatingcurrent,2-wiresystem
Three-phasecurrent,3-wiresystem
Three-phasecurrent,4-wiresystem
44
Meter reading and bus operation while the electric circuit is switched offThemetercanbeoptionallyequippedwitha24VDCauxiliarypowerinput(H1)forassureddischarge-freevoltage,whichallowsfordirectmeterreading,orremotemeterreadingforbuscompatiblevariants,evenwhentheelectricalcircuitisswitchedoff.TheuseofaUBAT-24Vbatterypackpermitsmeterreadingswithoutcontinuouslyactivesupplypower.
Technical dataMeas.input: Nominalvoltage100–110V(P–P),230V(P–N),400V(P–P),500V(P–P) Nominal frequency 50 Hz or 60 Hz Direct:Nominalcurrent5(65)A Transformer:Nominalcurrent1(6)Aand5(6)ASystemconfiguration: 2-wirealternatingcurrent,3-wireor4-wirethree-phasealternatingcurrentMeasured variables: Activeenergyandinstantaneouspowerinstandardvariants;currents,voltages,
active, reactive, apparent power, power factor, frequency optionalDisplay: LCD,7-digitmaindisplay,8-digitancilliardisplayS0output: PulseoutputaccordingtoEN62053-31or230V PulserateandpulsedurationfixedoradjustableInterface: OptionalLON,M-busorL-busAccuracy: Class1accordingtoEN61036Approval: DesignapprovalD,A,CH,CZ,HRAssembly: DINrailsaccordingtoEN50022
Stock variants
Article number Description
U1281-V001 2-wiresystem,230V,5(65)A,S0,pulserateprogrammable
U1281-V002 2-wiresystem,230V,5(65)A,S0,1000pulses/kWh,calibrated
U1289-V001 4-wiresystem,3x230/400V,5(65)A,S0,1000pulses/kWh
U1289-V002 4-wiresystem,3x230/400V,S0,5(65)A,1000pulses/kWh,calibrated
U1289-V003 4-wiresystem,3x230/400V,S0,5(65)A,pulserateprogrammable
U1381-V001 2-wiresystem,230V,5//1A,S0,CT/VT/pulserateprogrammable
U1381-V002 2-wiresystem,230V,5//1A,S0,1000pulses/kWh,CT=VT=1,calibrated
U1387-V001 3-wiresystem,3x100V,1A,S0,CT/VT/pulserateprogrammable
U1387-V002 3-wiresystem,3x100V,5//1A,S01000pulses/kWh,CT=VT=1,calibrated
U1387-V003 3-wiresystem,3x400V,5//1A,S0,CT/VT/pulserateprogrammable
U1387-V004 3-wiresystem,3x400V,5//1A,S0,1000pulses/kWh,CT=VT=1,calibrated
U1389-V001 4-wiresystem,3x230/400V,5//1A,S0,CT/VT/pulserateprogrammable
U1389-V002 4-wiresystem,3x230/400V,5//1A,S0,1000pulses/kWh,CT=VT=1,calibrated
U1389-V003 4-wiresystem,3x230/400V,5//1A,S0,CT/VTpulserateprogrammable,LON
U1389-V004 4-wiresystem,3x230/400V,5//1A,S0,CT=VT=1,LON,calibrated
AccessoriesBatterypackformeterreadingwithoutcontinuouslyactivepowersupplyUBAT-24VInstallationsetfordoorassemblyU270APlug-oncurrenttransformersASK31.3,ASK63.4,ASK105.6,ASK412.4WindingcurrenttransformerWSK30,WSK40,WSK70.6N
Electric energy meter with power display
Gossen MetrawattEnergy Meters
45
U389A
U389B
Acquisitionofactiveenergyin4-wirethree-phasesystemsaccordingtoEN61036.
Customer benefit• PreciseactiveenergymeasurementaccordingtoEN61036,class1• Directconnection5(65)A,withoutadditionalcurrenttransformers• Transformerconnection5//1A• Canbereadwhileelectriccircuitisswitchedoff• Errorrecognitionforreverse-poledcurrentdirection• PulseoutputS0• Compactdesignrequireslittlespace
ApplicationTheenergymetersmaybeuniversallyusedfortheacquisitionandinternalbillingofelectricalenergyintrade,household,industryandbuildingmanagementapplications.ThedirectlymeasuringU389A is designed for currents up to 65 A and saves costs for the installation of additional current transformers.TheU389Bvariantfortransformerconnectiontakesbothx/1Aandx/5Acurrenttransformers.Theconnectiontoacquisition,billingandoptimisingsystems,buildingautomationandcontrol engineering applications is achieved via the standard pulse output. Current transformers connected with reversed polarity and reversed direct connection are recognized and displayed as errors.
Technical dataMeasurement input: Nominalvoltage230/400V(P-N/P-P), nominal frequency 50 Hz, Direct: Nominalcurrent5(65)A Transformer:Nominalcurrent1(6)Aand5(6)ASystemconfiguration: 4-wirethree-phasealternatingcurrentDisplay: 7-digitdrum-typecounterS0output: PulseoutputaccordingtoEN62053-31 Direct: 100pulses/kWh Transformer:1000pulses/kWhAccuracy: Class1accordingtoEN61036Assembly: DINrailsaccordingtoEN50022
Stock variants
Article No. Description
U389A 4-wiresystem,3x230/400V,5(65)A,S0,100pulses/kWh
U389B 4-wiresystem,3x230/400V,5//1A,S0,1000pulses/kWh
AccessoriesInstallationsetfordoorassemblyU270APlug-oncurrenttransformersASK31.3,ASK63.4,ASK105.6,ASK412.4WindingcurrenttransformerWSK30,WSK40,WSK70.6N
Electric energy meter with drum-type counter
Gossen MetrawattEnergy Meters
46
Overview
Gossen MetrawattEnergy Control System (ECS)
Energy Control System (ECS) – professional solution for industrial applications
TheEnergyControlSystemistheprofessionalsolution for industrial energy data acquisition andprovidesallofthebasicsrequiredforconsumption and load optimizing, as well as costcentrebilling.Thesystemmeetsthehighestdemands:
• Synchronizationtothepowerutility’smeasuring interval
• Flexiblegroupingofmetersaccordingtotypeand installation density
• Autonomousevaluationanddatastorageatthe summators
• Adaptablenetworktopologyandutilizationofalreadyinstalledcables
• High-speeddatatransmissionsuitableforlarge installations
• Web-orienteddataread-out,analysisandbillingsoftware
47
ThesummatorsoftheEnergyControlSystemacquiremeterdataviadifferentinterfacesandevaluatethe same via internal calculation channels. The thus determined values for energy or consumption are summated synchronously to the measuring interval of the power utility over predefined time periodsandaprogrammableinterval,andarestoredtogetherwiththerespectivemaximumvalues.Usingthisautonomousenergydatabase,allelectricalandnon-electricalenergyandconsumptionvaluescanbeacquired,visualised,optimisedandbilledinrelationtocostcentres.
Individualsummatorscanbeinterconnectedovergreatdistancesviathemulti-mastercompatibleECSLANwithafreelyselectablenetworktopology.AllnetworkusershaveunlimitedaccesstoanydatainthenetworkandmakethesameavailableattheirserialRS232interface.AnalysingsoftwarepackageshavethenaccessviathecompanynetworkeitherdirectlyorusinganEthernetTCP/IPnetworkadapter.Modemsenableremoteacquisitionviapublictelephonenetworks.
DuetoitshighlevelofintegratedintelligenceandtheECLcustomprogramminglanguageeverysummatorisabletoexecutecustomisedcalculations,evaluations,monitoringandoptimisation.Externalprocessesarecontrolledviauser-specificbackgroundprogramswithpartlyavailableswitching or analogue outputs.
TheECSwinsoftwareisusedtoparameterisesummatorsandforsimpledataacquisition(seePage62).TheEMCsoftwarepackage(seePage64)providesconvenientfunctionsfordataread-out,analysisandbilling.
U1600 U1601 U1602 U1603
Display LCD, 2 lines of 16 characters
LCD, 16 lines of 21 characters
– –
Inputs 24 12 – 6
Input signals
S0pulses S0pulses,analogue signals ±10V,±20mA
– S0pulses, analogue signals ±10V,±210mA
Outputs 4 8 – 8
Outputsignals
Relay contact (switch)
2 relay contacts 2 analogue outputs (±20mA)4MOSswitches
– 2 relay contacts 2 analogue outputs (±20mA) 4MOSswitches
Calculationchannels
32 64 64 64
LONbus – FTT-1078k/Bit/s
2xRS23219200Bit/s (splitcablerequired) 115kBit/s
Overview of summators
Gossen MetrawattSummators
48
U1600Summator – 24 pulse inputs
Gossen MetrawattSummators
Customer benefit• Autonomousacquisition,calculationandstorageofenergyandconsumptiondataforupto 32freelyallocatableinputchannels
• Determinationofloadprofileswithsimpleenergymeters• 24pulsinputstoconnectenergymeters• SynchronisationtomeasuringintervaloftheutilityviaECS-LAN• SimplenetworkingviaECS-LANin2/4-wiretechnology• LocaldataprocessingviaECLprogramminglanguageECL• Convenientdisplayandprogrammingonsite
ApplicationThe U1600 summator is designed for the direct connection of 24 energy and consumption meters withpulseoutput.Itisparticularlysuitedtotheacquisitionofalargernumberofmeterswithpulseoutputinstalledintightspaceconditions.Devicesettingsandchannelparametersmaybedirectlychanged and acquired values viewed on sight via the display and the operating elements.
Technical dataInputs: 24pulseinputs,S0Outputs: 5Relays,changer,50VDC/0.5A 24 VDC power supply source, max. 0.4 AInterfaces: 2RS232,19.2kBit/s 2ECS-LAN,RS485,62.5kBit/s,2-/4-wiretechnologyStoragedepth: 10daysfor32channels@15minutesinterval Optionalstorageextensionto70daysDisplay: LCD,2linesof16characters,backgroundlightingPower supply: 80 – 250 VAC/DC, 19 VA Optional20–80VDC,15WDimensions: 240 mm x 125 mm x 80 mmAssembly: DINrailsaccordingtoEN50022
Stock variants
Article No. Description
GTU1600000E0001 80 – 250 V AC/DC
GTU1600000E0002 20 – 80 V DC
AccessoriesForconfigurationsoftwareECSwinseePage62ForloadoptimisingmoduleECSoptseePage63ForEMCsoftware„Energymanagementwithsystem“seePage64ForU1600Excel-MacroseePage63
49
U1601
Customer benefit• Autonomousacquisition,calculationandstorageofenergyandconsumptiondataforupto 64freelyallocatableinputchannels
• Determinationofloadprofileswithsimpleenergymeters• 12configurableinputsforanalogueordigitalsignals• Connectionofupto63energymetersviaLON• ExtendablyinputswithexternalacquisitionmodulesviaLON• SynchronisationtomeasuringintervaloftheutilityviaECS-LAN• SimplenetworkingviaECS-LANin2/4-wiretechnology• LocaldataprocessingviaECLprogramminglanguage• Convenientdisplayandprogrammingonsite
ApplicationThe U1601 summator is designed for the direct connection of 12 energy and consumption meters withanalogueorpulseoutput.EveryinputcanbesettotherequiredsignalviaaDIPswitch.Thesummatorisparticularlywellsuitedtoapplicationsrequiringaflexibleinputarrangementorconvenient display and programming on site.
TheLONinterfacepermitsthedirectconnectionofelectricalenergymetersoftheU128x(W1)andU138x(W1)series.Alocalorseparatedinputextensionforthesummatorcanbearrangedviathesame interface. To this end, the U1660 meter acquisition module offers eight pulse inputs and the U1661 analogue acquisition module six analogue inputs.
Altogether64physicalinputchannelsarepossibleforthesummatorandmaybefreelyallocatedtothe calculation channels.
Technical dataInputs: 12universalinputs,±5mA,±20mA,±10V, S0pulseadjustableOutputs: 2analogueoutputs,±20mAor±10Vadjustable 3 relays, changer, 250 VAC/8 A 4MOSrelay,switch,50VDC/0.2A 24 VDC power supply source, max. 0.15 AInterfaces: LON,FTT-10A,78kBit/s 2RS232,115kBit/s 2ECS-LAN,RS485,62.5kBit/s,2-/4-wiretechnologyStoragedepth: 40daysfor64channels@15minuteintervalsDisplay: LCD 128x128 Pixel, 16 lines of 21 characters, backgroundlighting Powersupply: 85–264VAC/100–280VDC,<15W(25VA) Optional20–72VDC,<15WDimensions: 212 mm x 125 mm x 85 mmAssembly: DINrailsaccordingtoEN50022
AccessoriesForconfigurationsoftwareECSwinseePage62ForEMCsoftware„Energymanagementwithsystem“seePage64ForU1600Excel-MacroseePage63
Summator with 12 universal inputs and LON
Gossen MetrawattSummators
50
U1602
Customer benefit• Autonomousacquisition,calculationandstorageofenergyandconsumptiondataforupto 64freelyallocatableinputchannels
• Determinationofloadprofileswithsimpleenergymeters• Connectionofupto63energymetersviaLON• SeparatedinputswithexternalacquisitionmodulesviaLON• SynchronisationtomeasuringintervaloftheutilityviaECS-LAN• SimplenetworkingviaECS-LANin2/4-wiretechnology• LocaldataprocessingviaECLprogramminglanguage
ApplicationTheU1602micro-summatorisdesignedforthedirectconnectionofelectricalenergymetersoftheU128x(W1),U138x(W1)andU168xseriesviatheLONinterface.Apartfromthedevelopmentofsystemsforpurelyelectricalenergyacquisitionitisparticularlywellsuitedtothecombinationofenergy and consumption meters placed in different areas.
Forthispurpose,alocalorseparatedinputextensioncanbearrangedforthesummatorviatheLONinterface.TheU1660meteracquisitionmoduleofferseightpulseinputsforthisandtheU1661analogue acquisition module six analogue inputs.
Altogether64physicalinputchannelsarepossibleforthesummatorandmaybefreelyallocatedtothe calculation channels.
Technical dataOutputs: 1relay,changer,250VAC/8A 24 VDC power supply source, max. 0.15 AInterfaces: LON,FTT-10A,78kBit/s 2RS232,115kBit/s 2ECS-LAN,RS485,62.5kBit/s,2-/4-wiretechnologyStoragedepth: 40daysfor64channels@15minuteintervalsPowersupply: 85–264VAC/100–280VDC,<15W(25VA) Optional20–72VDC,<15WDimensions: 212 mm x 125 mm x 85 mmAssembly: DINrailsaccordingtoEN50022
AccessoriesForconfigurationsoftwareECSwinseePage62ForEMCsoftware„Energymanagementwithsystem“seePage64ForU1600Excel-MacroseePage63
Micro-summator with LON
Gossen MetrawattSummators
51
U1603
Customer benefit• Autonomousacquisition,calculationandstorageofenergyandconsumptiondataforupto 64freelyallocatableinputchannels
• Determinationofloadprofileswithsimpleenergymeters• 6configurableinputsforanalogueordigitalsignals• Connectionofupto63energymetersviaLON• ExtendablyinputswithexternalacquisitionmodulesviaLON• SynchronisationtomeasuringintervaloftheutilityviaECS-LAN• SimplenetworkingviaECS-LANin2/4-wiretechnology• LocaldataprocessingviaECLprogramminglanguage
ApplicationTheU1603mini-summatorisdesignedforthedirectconnectionof6energyandconsumptionmeterswithanalogueorpulseoutput.EveryinputcanbesettotherequiredsignalviaaDIPswitch.Theinputsandoutputsmakethemini-summatoroptimallysuitableasasmallacquisitionandoptimisation unit for different media at the supply point of the energy utility.
Ifmainandsubdistributionsystemaretobeincludedintheacquisitionsystemsubsequently,theextensioncanbeachievedviatheLONinterfacewithelectricenergymetersoftheU128x(W1),U138x(W1)andU168xseries.Alocalorseparatedinputextensionforthesummatorcanalsobearranged via the same interface. To this end, the U1660 meter acquisition module offers eight pulse inputs and the U1661 analogue acquisition module six analogue inputs.
Altogether64physicalinputchannelsarepossibleforthesummatorandmaybefreelyallocatedtothe calculation channels.
Technical dataInputs: 6universalinputs,±5mA,±20mA,±10V,S0pulseadjustableOutputs: 2analogueoutputs,±20mAor±10Vadjustable 3 relays, changer, 250 VAC/8 A 4MOSrelay,switch,50VDC/0.2A 24 VDC power supply source, max. 0.15 AInterfaces: LON,FTT-10A,78kBit/s 2RS232,115kBit/s 2ECS-LAN,RS485,62.5kBit/s,2-/4-wiretechnologyStoragedepth: 40daysfor64channels@15minuteintervalsPowersupply: 85–264VAC/100–280VDC,<15W(25VA)
Optional20–72VDC,<15WDimensions: 212 mm x 125 mm x 85 mmAssembly: DINrailsaccordingtoEN50022
AccessoriesForconfigurationsoftwareECSwinseePage62ForEMCsoftware„Energymanagementwithsystem“seePage64ForU1600Excel-MacroseePage63
Mini-summator with 6 universal inputs and LON
Gossen MetrawattSummators
52
Overview ECS with SMARTCONTROL
Energy Control System (ECS) with SMARTCONTROL – the professional solution for industry and building management applications
The energy control system with SMARTCONTROLisaprofessionalsolutionfor acquisition, visualisation, optimisation and billing.Itrecordsallenergyandconsumptiondata required for the development of an energy managementsystemaccordingtoEN16001.This provides all of the information required to
reduce consumption efficiently and to optimise loads of the most varied media. The intelligent SMARTCONTROLcanissuealarmsearlyonor even switch off individual loads in case of disturbancesorwhenlimitvaluesaresurpassed.TheEMCapplicationsoftware,whichispartof the system, gathers all of the information
fromtheSMARTCONTROLsinthedifferentcompanyfields,storesitinacentraldatabaseandprovidesanalysesviaawebsiteforIntranet or Internet access.
Gossen MetrawattSummators
System architecture
Application example
Man
agem
ent l
evel
visualising,optimising,billing
Cons
olid
atio
n le
vel
visualising,optimising,billing
Acqu
isiti
on le
vel
mea
surin
g, m
eter
ing
EMCClient 1
2+4*switchingoutputs
SMSe-mail
Analogue,ISDN,GSMtelephonenetwork
Level converter
M-Bus Modbus 8 analogue signals
Utility Billingforthepastperiod
meter reading 15min power maxima
8 temp.PT1000
8+24*pulsesstatus signals
Modbus M-Bus LON
LON*
*Option
Electricity
Quantitypulse(S0)
SYNC(15min)
HT/NT
Quantitypulse(S0)
Quantitypulse(S0)
Quantitypulse(S0)
Water
Gas
Meter reading
Meter reading Load profile
Heat
2 analogue outputs*
Direct outputs
BUS systems Direct inputs
Historic data
Energy carrier
Feed Main / subdistribution
SMS, e-mail
EMC softwareCurrent data (15 min)
Communication
EMCClient 2
EMCClient n
EMCsoftware
SMARTCONTROLmanager
Energydata server
Control technologyserver
Data access
53
U200A SMARTCONTROL ECS – Energy Control System
Customer benefit• Acquisitionofenergyandconsumptiondata,temperatures,switchingstatusesandprocessvariables
• Errormessagemanagement,continuouscomparisonofcharacteristicvaluesandindicationoferrorsviaswitchingoutput,e-mailorSMS
• Peakloadmanagementincombinationwithswitchingoutputs• Timerprogramsandswitchingofrelaysaftertheoccurrenceofpredefinedevents• Calculationofmeanvaluesandintegrals,aswellasheatandcoldquantities• SMARTCONTROLmanagerconfigurationanddataread-outsoftwareincludedinthescopeof
delivery
ApplicationThemultitalentedSMARTCONTROLsupplementstheEnergyControlSystem(ECS)whichiswidespreadinindustryandbuildingtechnology.Itunitesenergyandconsumptiondataloggingforawidevarietyofmediawithloadmanagementanderrormessagingfunctions.Itcanbeusedautonomously,ortogetherwithEnergyManagementControl(EMC)softwarewithintheECS.Bothsolutionscontributetosustainedconservationofvaluableresourcesandreducedenergycosts.
The versatile data collector can acquire directly meter readings, temperatures, statuses and analogue signalsviaexistinginputs.Theconnectionofbus-compatibleinstrumentsorenergymetersiseffectedbyModbusviaM-BuswithanoptionallevelconverterorviatheopionalLONinterface.
ThedifferentparametersandfunctionsofSMARTCONTROLaredefinedviaSMARTCONTROLmanageranditsgraphicprogrammingsurface.Inparticular,linkingoftheinputswithcalculations,logicfunctions,timeprograms,relay,analogue,SMSande-mailoutputsiseasilyrealised.Theacquiredchanneldatamayalsobereadout,visualisedintablesordiagramsandexportedincsvorbmpformat.
SMARTCONTROLisintegratedintoexistinginfrastructuresviaEthernetTCP/IP.Thetalentedcommunicatormayalsobeequippedwithaninternalanaloguemodem,ISDN,GSMorBluetoothmodule.AnOPCserverisavailableforaneasyconnectiontoprocessandbuildingcontrolsystems.
Theinternal2MBflashringbuffercanbeextendedbytheinstallationofa2GBCompactFlashmemory card.
Technical dataInputs: 8digitalinputs,adjustabletoactiveorpassive 8analogueinputs0–20mAor0–10V,adjustable 8 temperature inputs for Pt1000 sensors
Optioninput/outputmodulefor24channels: 24digitalinputs,activeorpassivesettingpossible
Outputs: 2semiconductorrelaysmax.40VDC/AC,1A
Optioninput/outputmodulefor24channels: 4semiconductorrelays*max.40VDC/AC,1A 2analogueoutputs*0-20mAor0-10Vsettingpossible *Maybeconfiguredindividuallyinsteadofadigitalinput.
Interfaces: EthernetTCP/IP10/100Mbit,ModbusRTU,RS485, M-BusviaRS232withoptionallevelconverter,2xRS232forfieldbusdevices
OptionLONinterfacemodule: LON,FTT-10A,78kBit/s
Memory: 2MBflash,optional2GBcompactflash
Powersupply: 12–24VDC,ext.powersupplyplug100–240VAC/12VDC,optionalpluggablepowerpack,seeaccessories
Dimensions: 225 x 210 x 70 mm
Gossen MetrawattSummators
54
Stock variants
Article No. Description
U200A SMARTCONTROLstandard
U200B SMARTCONTROLcontrolcabinetIP65with12VDCpowerpack
U200C SMARTCONTROLcontrolcabinetIP65with24VDCpowerpack
U200D SMARTCONTROLstandardwithI/O24
U200E SMARTCONTROLstandardwithLON
U200F SMARTCONTROLstandardwithI/O24andLON
AccessoriesPluggablepowerpack100–240VAC/24VDC/24W Z301ULONextensionset** Z301VI/O24input/outputmodulefor24channelextensionset** Z301WAnaloguemodemsocketmoduleforanaloguetelephonenetwork Z301CISDNmodemsocketmoduleforISDNtelephonenetwork Z301DGSM/GPRSmodemsocketmoduleforGSMtelephonenetwork Z301EBluetoothsocketmoduleforradiocommunication Z301F
**Requirement:SMARTCONTROLbasicPCBstartingRev.2.3x
For further accessories see data sheet and price list.
SMARTCONTROL ECS – Energy Control System
Gossen MetrawattSummators
55
Z301A
Z301B
U1660
U1661
U1664
ECS-LAN router
ECS-LAN booster
Meter acquisition module for LON
Analogue input module for LON
Bus termination for LON
Gossen MetrawattAdditional Components for Summators
Star-typeECS-LANtopologiesmaybearrangedwithseveralrouterswhichareconnectedviaa2-wirebus.Theoutputshavea4-wirebusdesignwithbooster.
• Integratedroutertooptimisedatatransmission• Suitablebusterminationresistor• Powersupply20–70VDC
TheboosterextendstheECS-LANtransmissiondistanceto4km.Aboosterhastobeinstalledatthebeginningandendoftheextendedtransmissionrange.
• Powersupply:20–70VDC
TheU1660meteracquisitionmoduleextendstheU1601,U1602andU1603summatorsby8externaldigitalinputsviatheLONinterface.Themoduleprocessesdatafromenergymeterswithpulseoutput(S0)orfloatingcontact.Theactiveinputsdonotneedanyadditionalvoltagesupplythusminimising wiring expenditure.
Article No. Description
U1660-V001 Meter acquisition module
TheU1661analogueinputmoduleextendstheU1601,U1602andU1603summatorsby 6analogueinputsviatheLONinterface.Themoduleprocesses4…20mAstandardsignalsor0…20mAstandardsignalsinamodifiedvariant.
Article No. Description
U1661-V001 Analogueinputmodule4…20mA
TheU1664busterminationisemployedinbus-typeLONtopologyas105Ωterminationattheend.Atthebeginningofthebus,theintegrated105Ωbusterminationofthesummatorisused.Infreetopology,theintegrated52.3Ωbusterminationisemployed.Thisisanalogouslyalsoapplicabletothe extended segment if a repeater is used.
Article No. Description
U1664 Bustermination
56
U1500
00:000
20
40
60
80
100
110kW
03:00 06:00 09:00 12:00 15:00 18:00 21:00 00:00
Systemtoreducepowerpeaks,extendableinstepsfrom8to64optimisingchannels.
Customer benefit• Minimuminterferenceintheproductionprocessduetothecombinedtrend-extrapolationprocess• Simultaneousoptimisingofdifferentmedia• Future-orientedsetpointmanagementspecifyingtheloadprofilefor7dayswith96valueseach• Inputsforoperatingfeedbackfromtheconsumers• Takesminimumandmaximummakingandbreakingtimesofthepowerconsumersinto
consideration• Specialcontrolprogramsforkitchenoptimisation
ApplicationElectricalpowerpricesforcustomerswithspecialcontractsconsistofenergycosts(inEURperkWh)forcurrentconsumption,andpowercostsforthemaximumpowervalue(inEURperkW).Areductionofpowerpeakscanreducecostsconsiderably.Poweroptimisationassumesthatthestart-upofconsumerswhichdrawlargeamountsofpowercanfrequentlybepostponedafewminuteswithoutsignificantlyaffectingoperations.Thisapplies,inparticular,topowerconsumerswhicharecapableofstoringenergytoacertainextent,e.g.heatersand refrigerators. Integrated time switching programs can lower the energy costs and optimise operationalprocedures.Thesystemcanalsobeusedforcost-orientedcontrolofconsumerswhichrequire other forms of energy, e.g. gas.
Technical dataInputs: 16,individuallyswitchable24VDCor230VAC,withpotential-isolatedintwogroupsOutputs: 9Relayschanger,250VACmax.2A,powersupply24VDC,max.100mAPower supply: 230 V AC, 50 Hz, max. 15 VADimensions: 240 x 160 x 60 mmAssembly: DINrailsaccordingtoEN50022
Stock variants
Article No. Description
U1500 A0 Optimisingcomputerfor8channels
U1500 A1 Optimisingcomputerfor8channels,extendableviasystembus
U1500 A2 Systemextensionfor8channels
AccessoriesForPCsoftwareconfigurationZ302CseePage62ForPCsoftwareonlinedisplayZ302DseePage62ForPCsoftwaregraphicdataanalysisZ302BseePage62
Load optimisation
Gossen MetrawattLoad Optimisation
Pow
er [k
W]
Saving potential
Cost of consumption:
Cost tariff (dependingonhoursofuse=ratioannualenergy/maximumpower):
Reduction
Reduction
PowerEnergy
Prices
Increase
Increase
57
MAVOLOG 10 S
3-phasesystemanalyserforvoltagequalityaccordingtoEN50160.
Customer benefit• MonitoringandevidenceofvoltageaccordingtoEN50160• Transparencyinenergyandpowervalues• Monitoringofpowerfactorandreactivepowercompensation
ApplicationTheanalyserisdesignedforallareasofapplication,fromtheproducer(utility)downtotheenergyconsumerandmaybeusedbothindividuallyandtogetherwithotherdevices. Theprofessionalmodel,MAVOLOG10S,hasvoltagemeasuringinputsandacquiresdips,interruptions and swells in excess of 10 ms, asymmetry, frequency, harmonics up to the 40th order aswellasTHDandflicker. Thedevicehascurrentmeasuringinputsinadditionandcanthusbeusedasauniversalpowermeasurementdevice.Itregisterstheprogressionofalmostallmeasuredvariablesinthree-phasesystems,acquiressystemdisturbancesandanalysesthevoltagequalityaccordingtoEN50160.
Technical dataMeas.input: 4xnominalvoltage100/400VAC(L-L),nominalfrequency50/60Hz 3x nominal current 1//5 ASystemconfiguration: 3-/4-wirethree-phasealternatingcurrentDisplay: AlphanumericLCD,1-line,60x10mmOutput: Relaycontact,50V,0.5AInterface: BidirectionalRS4852-wirebus,9.6…115kBit/s,max.32participantsPower supply: 16 – 36 VDC, max. 3 WDimensions: 100 x 75 x 105 mmAssembly: DINrailsaccordingtoEN50022
Stock variants
Article No. Description
M830R MAVOLOG10S
AccessoriesMAVOLOG PS/CPowerpack230V/24VDCandinterfaceconverterRS485/RS232 Z863D
MAVOLOG PS/C universalWide-rangepowerpack60–320VDC,50–230VAC/24VDC andinterfaceconverterRS485/RS232 Z863G
MAVOLOG BP DCemergencyback-upforMAVOLOG10incaseofsystemfailure Z863E
METRAwin 10 / MAVOLOGParameterisingandvisualisingsoftware Z852D
PC.doc-ACCESS / MAVOLOGDatabasesoftwaretopreparetablesanddiagramswithMS-OfficeproductsACCESS,EXCEL,WORD Z852F
Power quality analyser
Gossen MetrawattPower Quality
58
MAVOSYS 10
Gossen MetrawattPower Quality
Monitoring system for the analysis of system quality, power and energy.
Customer benefit•Combinationwithuptofourvirtualanalysersinonehousing•Inputmodulesfor4xvoltage,4xcurrent,8xdigitalsignal•Localoperatingandvisualisingviatheoptional¼VGAtouchscreen•CertificationaccordingtoIEC61000-4-30,ClassA•TimesynchronisationviatheNTPtimeserverand/oroptionalGPSreceiver•Crosstriggeringinternalandexternal•Conformitywithallnationalandinternationalstandards•Ethernet10/100BaseT,RS232,RS485interfacesasastandard•CommunicationprotocolsTCP/IP,HTTP,XML,ModbusTCP/RTU
ApplicationAs soon as an indication of poor system quality occurs, effective action is required. Typical indications includeoverheatedmotors,transformers,lines,excessivecurrentsinneutralconductors,flickeringlights,computersorinexplicablerisesinenergycosts.UsingMAVOSYS10,disturbancesandeventscanbeeasilylocalised,documentedandanalysedwithrespecttostandards,alsowithinthemostcomplexsystems–theperfectbasisforstustainedoptimisation.Thisincreasesoperationalsafety,keepsuptheproductqualityandensuresahighdegreeofcostefficiency.
Pathbreaking innovationMAVOSYS10constitutesarealbreakthroughintechnology:It is the first system analyser to surpass the classic maximum limit of 8 channels for voltage and currentinputs.Usersmaynowchoosebetweeninputmodulesforvoltages(4channels),currents(4channels)anddigitalsignals(8channels).Applicationspreviouslyrequiringtwoormoredevicesmaynowberealisedbyacombinationofupto4modulesinoneMAVOSYS10.Thissavesspaceand reduces costs.
Commoncombinationsare:
• 8channelsfortraditionalmonitoringofthesystemqualityandpower: one input module each for voltage and current
• 16channelsforfunctionmonitoringofplants,suchasuninterruptedpowersupply(input/output): two input modules each for voltage and current• 16channelstomonitorthesupplyofsubstations: Oneinputmoduleforvoltageandthreeforcurrent.
Preconfigured complete systems (nochangespossible)
Type Description Article No.
61STDPQ Basicunit61STD,4slots,1x61MVS,1x61MAS5 M818A
61SG-PQ Basicunit61SG,4slots,1x61MVS,1x61MAS5 M818B
61SGD-PQ Basicunit61SGD,4slots,1x61MVS,1x61MAS5 M818C
61VCM Monitorforvoltagemonitoring,1slot,1x61MVS M818D
System failure analysers
Voltage conformity
Standardpowerquality
4 channel voltage module 4 channel current module
Subdistribution
UPSmonitoring
59
Content Software, Accessories
Software for heavy current transducers and power metersConfiguration software ............................................................................................................ 60
CB-Manager ............................................................................................................................ 61
CB-Analyzer ............................................................................................................................ 61
Profibusmini-CD ..................................................................................................................... 61
Software for energy managementZ302B,Z302C,Z302D ............................................................................................................. 62
ECSwin,configurationsoftwareforU160x ................................................................................. 62
ECSopt,moduleloadoptimisingforECSwin ............................................................................... 63
U1600Excel-Makro ................................................................................................................. 63
EMC,energydatamanagementwithsystem.............................................................................. 64
EncoreSeries .......................................................................................................................... 65
Accessories for heavy current transducers and power metersProgrammingandadditionalcables .......................................................................................... 66
BasicsElectromagneticcompatibility ................................................................................................... 67
Environmentaltesting ............................................................................................................... 69
Camille Bauer, Gossen MetrawattSoftware, Accessories, Basics
60
Camille BauerSoftware for Heavy Current Transducers and Power Meters
Configuration software
ToparameteriseprogrammableCBdevices.
AllsoftwareproductsofCamilleBauercanbeusedONLINE(connectedtothedevice)andOFFLINE(withoutaconnecteddevice).Inthisway,parameterisingandthedocumentationforalldevicestobeusedcanbeperformedandstoredpriortocommissioning.TheCDcontainsthefollowingPCsoftware:
DME4• Programmingofallfeaturesoftherespectivedevicevariants• Measuredvaluedisplayofanalogue/digitaloutputvaluesaswellasallvariableswhichcanbe
acquired• Simulationofoutputstotestsubsequentcircuits• Printingofconfigurationandnameplates• Resettingofslavepointers• Setting/resettingofmeterreadings• Passwordprotectionforselectablefunctions
M560• Programmingofallfeaturesoftherespectivedevicevariants• Visualisingofmeasuredvalueswithrecorderrepresentation,storagepossibilityandsubsequentanalysismode,measuredvaluefilecanalsobeexportedtoExcel
• Simulationofanalogueoutputstotestsubsequentcircuits• Printingofconfigurationfilesandnameplates• Resettingofslavepointers• Graphicrepresentationofthelinearisationcharacteristicofeachoutput• Passwordprotectionforselectablefunctions
A200plus, A200plus handheld• Acquisitionandchangeofalldevicefeatures• Measuredvaluedisplayofallacquiredvariables• Acquisition/setting/resettingofmetersandminimum/maximumvalues• Acquisitionandvisualisingofmeanvaluesstoredinthelogger• DirectexportofloggerdatatoMicrosoftExcel
The CD contains further PC software for angular position and process control engineering.
Content of the CD
Software For devices Language Operating system
VC600 SINEAX/EURAXV604,VC603, SIRAXV644
D,E,F,N 9x,NT4.x,2000,ME,XPVista,7(32-Bit)
V600plus SINEAXVK616,VK626,V608,V624,V611,SIRAXV606
D,E,F,N,I,S
9x,NT4.x,2000,ME,XPVista,7(32-Bit)Vista,7(64-Bit)
TV800plus SINEAXTV809 D,E,F,N
DME4 SINEAX/EURAXDME4xx D,E,F,N,I
M560 SINEAXM561,M562,M563 D,N,F,N,S
2W2 KINAX2W2,WT711,WT717andSR719 D,E,F,N
A200plus SINEAXA210,A220,A230,A230s withEMMOD201orEMMOD203
D,E,F,N
A200plus handheld
A210-HH,A230-HH D,E,F,N
Article No. Description
146 557 Configurationsoftware(CD)
61
CB-Manager
Fortheuniversalmeasuringunitforheavy-currentvariablesSINEAXCAMandAPLUS.
ThissoftwarepermitsONLINE/OFFLINEparamiterisingofSINEAXCAMandAPLUS as well as visuali-sing measured values. It also supports users in commissioning and service. The program design is system-orientedandthusenablesthesimultaneouscommunicationwithseveraldevices.• Acquisitionandchangeofalldevicefeatures• Settingofreal-timeclockandtimezone,selectionofthetimesynchronisationmethod• Archivingofconfigurationandmeasuredvaluefiles• Visualisingofinstantaneousvalues• Acquisition,settingandresettingofmetersandminimum/maximumvalues• Starting,stoppingandresettingoftheoptionallogger• Recordingofmeasuredvalueprogressionduringcommissionning• Checkofcorrectdeviceconnection• Simulationofoutputstotestsubsequentcircuits• Userandaccesssettingfortheprotectivepasswordsystem
ThesoftwaremayalsobeusedforthemodularcontrolsystemSINEAXVR660/A200RandthemultifunctionaltransducerSINEAXV604s.
Article No. Description
156 027 Doku-CD,incl.configurationsoftwareCB-Manager
ThisCDispartofthescopeofdeliveryofSINEAXCAM,APLUS,SINEAXVR660andV604s.
CB-Analyzer
Fortheuniversalheavy-currentmeasuringunitsSINEAXCAMandAPLUS.
The.NET-basedsoftwarefacilitatesthedataacquisitionandanalysisoftheoptionaldataloggersandlistsofSINEAXCAMandAPLUS.Thedatawillbestoredinadatabasesothatamuchlongerhistoryisbuiltupthanwouldbethecaseifonlythepresentmemorycontentofthedevicewasanalysed.Theprogramiscapableofprocessingseveraldevicessimultaneously.• Acquisitionofloggerandlistdataofseveraldevices• Storageofthedatainadatabase(Access,SQLClient)• Reportgenerationinlistorgraphicformat• Selectabletimerangeinthepreparationofreports• ExportofreportdatatoExcelorasanAcrobatPDFfile• Differentanalysingoptionsoftheacquireddata,alsoacrossdevices
Article No. Description
156 027 Doku-CD,incl.analysissoftwareCBAnalyzer
ThisCDispartofthescopeofdeliveryofSINEAXCAM,APLUS,SINEAXVR660andV604s.
Profibus Mini-CD
FortheDME406multi-transducerandtheEMMOD204extensionmodule.
TheCDcontainstherespectiveGSDfileandtheoperatinginstructionsaswellasacommissioningguidelineandfurtherProfibusdocuments.
Article No. Description
150 764 Profibusmini-CD
ThisCDispartofthescopeofdeliveryofSINEAXDME406.
Camille BauerSoftware for Heavy Current Transducers and Power Meters
62
Z302B / Z302C / Z302D
ECSwin
Gossen MetrawattSoftware for Energy Management
ThelistedsoftwarepackagesarenotrequiredforthebasicfunctionoftheU1500optimisingsystembuttheyofferusefuladditionalfunctionsforenergyconsultantsandinterestedusers.AllpackagesworkunderWindows95,98,ME,NT,2000,XPandcontainthebasicmodulesofdatatransfer, configuration signals and channel monitor.
Load optimising configuration module Z302CAlloftheconfigurationsandsettingsrequiredforthedevicecanbeconvenientlyenteredatthePC,stored to memory, displayed, printed out and transmitted to the optimising computer.
Recommended for those who frequently start up optimizing systems, or have to adapt existing configurations.
Online display module Z302DData for the current measuring period and the current switching statuses of interconnected operating equipmentcanbedisplayedonlinewiththissoftware. Recommended for those who always want to have a good overview of their optimising system during any given measuring period.
Graphic data analysis module Z302BThis module allows for graphic analysis of all archived data such as load characteristics and switchingoperations.Recurrentdataanalysisisexecutedafterthegraphicconfigurationhasbeenselected and stored to memory once only.
Recommendedforthosewhowanttodocumentsavingsgeneratedbythesystem,aswellasanalyzeand optimise the switching operations required to this end.
PC software for load optimising
Configuration software for U160x summators
ConfigurationoftheU160xsummator,manualread-outofstoredenergydataandsimplevisualising.
Customer benefit• ConvenientconfigurationofU160xsummators• Easyprogrammingofvirtualchannels• Directcommandentryviaterminalfunction• Graphicrepresentationofcontrolpanelforremotecontrol• GraphicrepresentationofECS-LANnetworktopology• Acquisitionandvisualisingofstoreddata• Recorderrepresentationforinstantaneousvalues• Optional:SimpleloadoptimisingforU1600withECSopt
ApplicationECSwinsoftwareconfiguresU1600,U1601,U1602andU1603summatorseasilyandconveniently.Parameter settings are read out from the summators, and are displayed in data entry windows. Allvaluesmaybechanged,savedtomemoryandtransferredtothesummators.ThesoftwarecanaccessthesummatorsviaRS232interface,modem,EthernetTCP/IPandCOM-Server.
Technical dataOperatingsystem: MSWindows95,98,NT4,ME,2000,XP,Vista
Article No. Description
Z302E ECSwin
63
ECSopt
U1600 Excel-Makro
4-channelloadoptimisingforU1600summators.
Customer benefit• Savingsinenergycostsbythereductionofpeakloads• Specificationormeasurementofloadswhichcanbeshutdown• Considerationoflimitvaluesdependingontariffperiods• Adjustablerotationofloadstobeshutdown• Considerationofreactiontimesofloads• Protocolofswitchingoperations
ApplicationPeakloadsarereducedbythecontrolofmax.4consumersincombinationwithECSwinandaU1600summator.Inaddition,the4switchingoutputsandthebackgroundprogrammingoftheU1600summatorareused.ParametersmaybeconvenientlysetviaECSwin.
Article No. Description
Z302F ECSopt
For data upload from U16xx summators.
Customer benefit• AvailabilityofenergydatainMSExcel• Preparationofanalysesandreports
ApplicationUsingtheU1600.XLMmacro,energydatafromtheU160xsummatorscanbedirectlyexportedtoMicrosoftExcelspreadsheets,Version4.xorhigher,andmadeavailableforcustomer-specificevaluation.ConnectionofthePCtothesummatorisconfiguredinExcel,andisestablisheddirectlyviatheRS232interface,modem,EthernetTCP/IPandCOM-Server.
Article No. Description
Z302G U1600Excel-Makro
Load optimising module for ECSwin
Macros for MS Excel
Gossen MetrawattSoftware for Energy Management
64
EMC
Applicationsoftwaretoacquire,visualiseandbillenergydatafromtheEnergyControlSystem(ECS).
Customer benefit• Remote read-out of meter data providestime-synchroniseddata,saveslong-distancetravelandavoidsreadingandinputerrors.Briefread-outintervalsresultinloadprofileswhichserveasabasisforoptimisingandbilling
• Diagrams create comprehensive transparency in consumption and load structures. They reveal weakpointsandconstitutethebasisforconsumption,processandmaximumoptimisation.
• Reports document the consumption and determine costs on basis of the allocated tariffs. They form the basis for responsible handling of energy, internal billing and contract negotiations with utility companies.
• Billingisinrelationtothetenantinletobjectsandtothecostcentreinindustrialoperations.Therequired administrative functions are integrated.
• Planned data the schedule in energy supply contracts. Deviations in relation to the real load curve arevisualisedandconstitutethebasisforscheduleoptimising.
• Virtual channelscalculatenewdataforallanalyses.Differentloadscanbecombined,distributedordeterminedviabalancingcircles.Benchmarkingisfacilitatedbythecalculationofkeyfigures.
ApplicationWorkingincombinationwiththehigh-performanceEnergyControlSystemtheuser-friendlyEMC(EnergyManagementControl)softwareisdesignedinanoptimumfashionforapplicationsinindustry,energyandbuildingmanagement.Energydataofallmediamaybereadremotely,stored,visualised,analysedandbilled.Browser-orientedoperationviatreestructuresandintegratedhelpfunctionssafeguardintuitiveoperationwithbrieffamiliarisationperiods.Severaluserscanaccesssimultaneouslythedataarchivedinahigh-performanceSQLdatabaseviaIntranetorInternet.Ausermanagementsystemcontrolsspecificaccessrights.Thesoftwareisofamodulardesignandcanbeadjusted to individual requirements.
Technical dataComputer: min.PentiumPC,1GHz,250MBRAMBrowser: InternetExplorerstartingVersion6.0SP1Operatingsystem: MSWindows2000SP4,XPLanguages: D,GB,F,I,NL,CZ,PLswitchable
Article No. Description
Z308A EMCBasicversion
Z308B EMCExpansion–ProvidersandTariffs
Z308C EMCExpansion–BuildingAutomation/IndustrialVersion
Z308D EMCExpansion–Consortium
Z308E EMCExpansion–VirtualChannels
Z308F EMCLicense–5User
Z308G EMCLicense–5Locations/EnergyTypes
Z308H EMCLicense–100MeasuringPoints
Z308I EMCLicense–5Companies
Z308J EMCFullVersion
Energy data management with system
Gossen MetrawattSoftware for Energy Management
65
Encore Series
Gossen MetrawattSoftware for Energy Management
Analysis and Evaluation Software for MAVOSYS 10
User-friendlyEncoreseriessoftwareisavailableforcontrollingandcommunicatingwiththeMAVOSYS10.Itallowsforvisualizationandanalysisofevents,sequencesandmeasuredvalues.
AutomaticevaluationscanbeexecutedwithoptionalAnswerModules®–intelligentalgorithmsforspecific data interpretation.
Mains Management SimplifiedWithEncoreseriessoftware,theMAVOSYS10canbeutilizedideallyinagreatvarietyofelectricalsystemswithalargespectrumofconfigurations.Thesoftware’sspecialstrengthsincludeapasswordprotectedmultiuserwebinterfaceandabroadrangeoffunctions:Evencomplexmonitoringandanalysistaskscanbeorganizedandprocessedinaclear-cutfashion.Encoreseriessoftware is thus ideally suited for convenient data acquisition and storage.
•Simpleuserinterfacebasedonawebbrowser•Upto50ormoreMAVOSYS10instrumentsaresupported•Mainsquality,demand,energyandprocessanalyses
Enterprisesoftwareisadditionallyavailableforextendedanalysesandmanagementofseverallogging systems.
Intelligent Analysis ExtrasDecadesofexperienceandexpertknowledgehavebeenengineeredintoourAnswerModules®–intelligentalgorithmsforautomaticinterpretationandcompilationofdata.They’reintegratedintoEncoreseriessoftwareasrequired,andtheyexpanditsrangeoffunctions.
Available AnswerModules®• Sag Direction: diagnosis of voltage sags and the direction to their cause• CapSwitchTM: analysisoftransientstriggeredbyswitchingcompensationcapacitors• kVAR Verification: monitoring of compensation systems for correct functioning• UPS Verification: monitoringofuninterruptiblepowersuppliesforcorrectfunctioning• Energy User: specific reports regarding energy consumption and costs• Radial Line Fault: ascertainment of cause and distance to faults in the mains• Reliability Benchmark: ascertainmentandevaluationofmainsreliability• Online-Diagram: customer-specificsystemdiagramswithindicationofcurrentstates,eventsand mains quantities
Type Description system software Article No.
EncoreSeriesSoftware
EncoreseriesserversoftwarefortheMavosysrange,customerPCrequirements:8GBharddisk,webserver,HASPkey
Z820A
DVE-PQDIF DranViewEnterpriseversionforreadingPQDIF,COMTRADEandtextfiles(USBHASPversion)
Z820B
NodeLink Enterprisesoftware,savesdatainPQDIFformat,forusewithPQView and DranView
Z820C
Type Description answerModule® (for Encore series software) Article No.
SWPFCAP AnswerModule – compensation capacitor directional characteristic Z820D
SWVAR VARtestinstrumentforSWPFCAPAnswerModule Z820E
SWSAG AnswerModule–voltagesagdirectionalcharacteristic(SAG) Z820F
SWUPS AnswerModule–USPfunctiontest Z820G
SWRADL AnswerModule – star line fault Z820H
SWEUAM AnswerModule – energy consumption Z820I
SWRBM AnswerModule–reliabilitytest Z820K
SWADAM Driver module – Advantech ADAM Z820L
66
147 779
980 179
143 587
152 603
154 071
168 949
Camille BauerAccessories for Heavy Current Transducers and Power Meters
Programming and additional cables
serve programming of the instruments in connection with the respective configuration software and using a PC.
Customer benefit• Programmingoperationwithoutanyadditionalpowersupplyconnection• Communicationwiththeinstruments• SafegalvanicisolationofinstrumentandPC• Cost-effectiveinstruments(M56x)duetoseparatedprogramminginterface
Article No. Description A2xx * A2000
A200 to DME4xx
DME4xx M56x EDS-CAM
147 779 Programmingcable PRKAB560(NEx)
•
143 587 Additionalcable •
152 603 Interfaceadaptercable •
154 071 Connectingcable Sub-D9pol.male/male
•
980 179 Extensioncable Sub-D9pol.male/female
• •
168 949 Connectingcable2m EDS-CAM<>SINEAXCAM
•
*A210,A230s,A230withplugged-onEMMOD201
67
Camille BauerBasics
Electromagnetic compatibility
What is it all about?Electromagneticcompatibility(EMC)signifiesthatelectricalandelectronicalproductsworksafely at their place of use. To safeguard this, the interfering emission of electromagnetic signals of devices, systems or plants must belimited.Ontheotherhand,itmustalsobesafeguardedthatdevices,systemsorplantsarenotimpairedbytheinterferingsignals present in their environment. These relatively simple facts are stipulated in the EMCDirective89/336/ECandcanonlybeachieved if all those involved play the game. Allmanufacturersareobligedtotesttheirproducts accordingly or have them tested.
TheCE-markisthebasicpreconditionthataproductmaybeputintocirculationinEurope.In this way, manufacturers confirm that their productsconformtoapplicabledirectivesfortheirtypeofproduct.TheEMCdirectiveisan integral part of this requirement profile. OutsideofEurope,otheridentificationobligationsarepartlyapplicable.Thesearenow harmonised to such an extent that also inrelationtoEMCcomparablerequirementscanbeassumed.
The problemThe increase of electrical and electronical products in the industrial environment butalsoinproductsofdailyuseisstillimmense. More and more functionality with even higher performance is implemented in these products. Processor systems with increasinglyhigherclockfrequenciesarebeingused.Theygeneratehigherandhigher
levels of interference unintentionally and also becomemoreandmoresensitivetointerferingsources in their environment.
Tomakematterworse,theapplicationsusing radio frequencies are also increasing. Forexample,mobiletelephonesmustbeina position of sending and receiving signals. Though their transmission output is limited, incompatibilitiesmightresultiftheyareusedinconsiderately in the vicinity of sensitive devices.Systemsmaybeinterferedwithtosuchan extent that they provide wrong signals or breakdowncompletely.Thisisthereason,whytheir use is often limited, e.g. in aircrafts or also in hospitals where sensitive medical devices mightbeaffected.TheawarenessofEMCproblemsinaircraftshasbeenestablishedoveryearsbutmuststillbepointedouttopassengerspriortoeverytake-off.Whenenteringahospitalhardlyanybodyturnsofhisorhermobiletelephone despite warning messages on the walls.Operationalmanagersofpowerplantsare often not aware of the fact that the use of mobiletelephonesinthevicinityofmeasuring,controllingandregulatingunitscanbecritical.Radioandtelevisionstations,mobileradioantennaeorremotecontrolsalsoworkwithfrequencies which might interfere with sensitive devices and impair their operation.
Sources of interferenceIn the industrial environment, frequency converters, motors and other consumers are increasingly operated parallel to sensitive measuring and control systems. Higher levels of interferencemustgenerallybeexpectedinall
places where high power is applied, switched or pulsed or electronic systems with high pulse frequencies are used.
The use of wireless telecommunication facilities ornetworksalsoincreasestheprobabilityofincompatiblelevelsofinterferenceintheenvironment of sensitive equipment.
StandardsApplicablespecificbasicstandardsdefinetherequirements of products and systems for use intheiroriginalenvironment.Alimitednumberof tests with evaluation criteria and the expected operatingbehaviouraredeterminedusingdefinedmeasuringandtestprocedures.Specificbasicstandardscontaindetailsofthemeasuringmethodandgeneralconditions.SpecificEMCstandardsareavailableforcertainproductsor product groups and have priority over the generalrequirementsmentionedabove. EMCsafetycanonlybeachievedbyacompleteexaminationinaccordancewithstandards.Sinceall standards are interrelated only their sum total provides a satisfactory result. Partial examination isnotpermitted,howeverstilldonebysomemanufacturersduetolackingmeasuringequipment or for reasons of costs.
Meeting standards does not necessarily provide smoothoperation.Adevicemaybesubjectedto higher loads in operation than envisaged bythestandard.ThismightbecausedbyinsufficientprotectionoftheequipmentorbyEMC-incompatiblewiring.Insuchacase,thebehaviourofthedeviceislargelyundefinedsinceithasnotbeentested. Tests at Camille BauerCamilleBauerhasitsownEMClaboratorywherethecompletescopeofallrequiredtests(seebelow)canbeperformed.Evenifourlaboratoryis not accredited, comparative measurements at the premises of respective service providers aswellassubsequentchecksbycustomersconfirmed our test results in each case.
We also test our devices under higher loads than demandedbythestandardevenifthisisnotexplicitly stated in our data sheets.
Specific basic standardsIEC / EN 61 000-6-2 Immunity standard for industrial environments
IEC / EN 61 000-6-4EmissionstandardforindustrialenvironmentsMeasurement of the behaviour of the devices in voltage dips, brief interruptions or voltage fluctuations of the
power supply
68
Camille BauerBasics
Electromagnetic compatibility
Basic standards IEC / EN 61 000-4-2Immunity to static discharge which occurs as potentialdifferences-mainlycausedbyfrictionelectricity-arereduced.Themostknowneffectis surely when persons get charged as they walkacrossacarpetanddischargedwiththegenerationofasparkwhentheytouchametalpart. If this is, e.g., the plug of an electronic devicethebriefcurrentimpulsemightbesufficient to destroy the device.
IEC / EN 61 000-4-3Immunitytohigh-frequencyelectromagneticfields. Typical sources of interference are radiotelephonesusedbytheoperating,maintenanceorservicestaff,mobiletelephonesand transmitting facilities needing these fields. Coupling happens via the air. Unintentional fieldsalsooccurinweldingfacilities,thyristor-controlled inverters or fluorescent lamps.
Couplingmightaswellbegeneratedviathelinein such cases.
IEC / EN 61 000-4-4Immunitytofasttransientinterferencevariables(bursts)whicharegeneratedinswitchingoperations(interruptionofinductiveloadsorbouncingofrelaycontacts)..
IEC / EN 61 000-4-5Immunitytoimpulsevoltages(surges)whicharegenerated in switching operations or lightning and arrive at the device via the connecting lines.
IEC / EN 61 000-4-6Immunitytoconducteddisturbances,inducedbyhigh-frequencyfieldswhicharetypicallygeneratedbyradiotransmissionfacilities.Couplingtakesplaceviatheconnectinglineofthe device. For further sources of interference see61000-4-3.
IEC / EN 61 000-4-8Immunity to magnetic fields with power frequencies.Strongmagneticfieldsresult,e.g., in the immediate vicinity of power lines orbusbars.
IEC / EN 61 000-4-11Immunitytovoltagedips,briefinterruptionsandvoltagefluctuations.Dipsandbriefinterruptions of the supply voltage result from errors in the supply system or when large loads are switched. Voltage fluctuations are causedbyfast-changingloads,e.g.inarcfurnaces,andalsogenerateflickering.
Determination of device behaviour under the influence of a magnetic external field generated by a Helmholtz coil
69
Environmental testing
Camille BauerBasics
What is it all about?Products are exposed to many environmental impacts during their useful life. These are not limited to impacts during operation in theintendedapplicationinthefieldbutalsocomprise detrimental influences during storage or transport to customers. The impacts include temperature, climate, water anddustconditionsbutalsomechanicalstresslikevibrationorshock.
Thetestshavetheobjectiveofcheckingtheresistanceagainstpossibleenvironmentalimpactsandtoensurereliabilityinlateroperation. Assumptions are made, e.g. concerning the reference range for environmental temperature or the annual average relative humidity. Users must compare these details with their own requirements(seedatasheet).Itisonlyafterthischeckthattheycanbecertainthatthedevice suits their applications and will show thedesiredbehaviour.
StandardsTherequirementoftestingthebehaviourofdevices in changing environmental conditions is derived from product group standards forCamilleBauerproducts,e.g.EN/IEC60688„Electricalmeasuringtransducersfor converting a.c. electrical quantities to analogueordigitalsignals“.Thenormalplace and type of use and the prevailing environmental conditions to which these instrumentsareexposedareknown.Testsand test criteria which the device has to meet are derived from this information. For firmly installed instruments these tests concern theoperationalbehavioursinchangingtemperatures(cold,dryandhumidheat)aswellastheinfluenceofvibrationandshocks.
OperationTheambienttemperatureinwhichadeviceisoperatedcanchangequickly,e.g.ifapart of the plant in which the device has beeninstalledheatsupduetooperationaldemandsorbecauseofthedifferenceofdayand night temperatures in rooms which are not heated. Usually, devices heat themselves up. This can occur due to dissipated heat ofpassivecomponentsorself-heatingofprocessors. Depending on the season and the environment,theheatmaybedryorhumid,i.e. precipitating or not precipitating. Thermic testingmighttakehoursordays.Thedeviceis operated under normal conditions, i.e. with
inputsignalsandloadedoutputs.Theambienttemperatureischangedstepbystepinregularintervals,keptconstantandthenchangedagain,either positively or negatively. In this way, the entire operating temperature range of the device is applied upwards and downwards. Any change inthebehaviourofthedeviceandtheextentofthesameisverifiedaftereachstep.Ontheonehand, the test shows whether the instrument meets the accuracy requirements within the reference range and, on the other hand, the temperature influence outside of the reference rangeischecked.
If the devices are installed in the vicinity ofrotatingmachines,assembledinshipsortransportedtocustomersbylorriesandaeroplanes, they are exposed to permanent vibration.Thismightleadtolargercomponentsbeingcutofformechanicallockingdevicesofthehousingsbeingopened.Vibrationtestinginwhichthetestedobjectisexposedtorepeatedharmonicvibrationhelpstofindweakpointsandtoeliminatethem.Shocktesting,ontheotherhand,subjectsthedevicetoaspecifiedformofshockthroughaccelerationandbreakingatirregularintervals.Inthisway,thebehaviourofthedevicecanbetestedifitisdroppedfromacertain level.
Special measurementsNot all instruments are used in applications coveredbystandardtests.Earthquakevibrationtests,forexample,requirelow-frequencyvibrationofahighamplitude.Ourtestfacilitiescannot process the required test schedule exactly. Therefore, the measurements have to bedoneexternally.Normally,customersassumethe costs for this service. Upon request, we will bepleasedtomaketestinstrumentsavailableifyou intend to perform the tests yourself. Standardtestscanalsobeperformedwithchanged general conditions. Whether and to what extent customers participate in the costs incurredwillbedecidedineachcase.
Tests at Camille BauerCamilleBauerhastestfacilitiestoperformallrequiredproducttestsin-house.
Overview of testsEN/IEC60068-2-1–coldEN/IEC60068-2-2–dryheatEN/IEC60068-2-78–humidheatEN/IEC60068-2-6–vibrationEN/IEC60068-2-27–shock
70
Camille BauerProducts for angular position engineering
Angular position transducers
Inclination transducers
TheangularpositiontransmittersfromCamilleBauerareprecisioninstrumentsandservestheacquisition of angular position and rotation, processing and the provision of measured values as electric output signals for the downstream device. They converts the angular position of a shaft into a load-independentdirectcurrentsignal,proportionaltotheangularposition.
TherobustdesignmakestheangularpositiontransmittersoftheKINAXWT7xxseriesparticularlysuitedtoapplicationsinroughenvironments.Theproductsareusedinmanyareas,preferablyinlarge machine construction, industrial plants, power plant construction, ship and offshore facilities, crane vehicles, large transport vehicles, dredger and drilling equipment.
ThecompactdesignoftheKINAXtobeinstalledorforsurfacemountingmakestheangularpositiontransmitters particularly suited to the installation in or mounting on devices and apparatuses. The productsareusedinmanyapplications,e.g.railwayengineering,industrialplants,shipbuilding,powerplant construction and gate positions.
Main features• Simpleconnectiontechnologywith2,3,4wireorplugconnectorM12• Absolutangularpositionisimmediatelyavailableafterswitchon• Nonmechanicalabrasion,lowannualmaintenance• Vibrationandshock-resistant• Versionsnonprogrammableandprogrammable• AnalogueordigitaloutputsignalsinCANopenandSSIwithM12-plugconnector• Availableintypeofprotection“Intrinsicsafety”EExiaIICT6
TheinclinationtransmitterfromCamilleBauerconvertsthetiltangleintoadirectcurrentsignal,proportionaltotheangle.TheoutputsignaliseitheravailableasananalogsignalinformofacurrentchangeordigitallywithaCANopenorSSIbusinterface.
Magnetoresistiveangularpositiontransmittersareextremelyrobustmeasuringsystemswithoutashaftstop,fullyhermeticallyencapsuledandcapableofmeasuringcontactlesstheangularpositionof a permanent magnet, which is attached to the pendulum system.
Tiltanglevaluesofaplatforme.g.oncranes,heavy-dutyvehicles,excavatorsanddrillingmachines,ships and offshore facilities stand for important measuring data as a part of the savety and control system of that type of machinery. Angular measurement, for instance for equipment levelling is performed in such cases.
Foracquisitiontheangularpositionofacranejib,lateralinclinationofavehicle,orientationofaliftingplatform,weirtraporcomparablefacilities,alignmentofsolarpanelsorconcavemirrorstheKINAXN702canalsobeused.
Main features• SimpleconnectionwithplugconnectorM12• Absolutangularpositionisimmediatelyavailableafterswitchon• Versionsnonprogrammableandprogrammable• AnalogueordigitaloutputsignalsinCANopenandSSIwithM12-plugconnector
71
Temperature
Camille BauerProducts of Process Control Engineering
Signal conversion
Process Management
Temperatureisthemostmeasuredvariableinindustry.However,therequirementsoftemperaturemeasuringpointsvaryfromoneapplicationtotheother.CamilleBaueroffersextensivetemperaturetransducers in the most varied designs for the analysis, conversion and transmission of temperature sensor signals.
Head transmittersHead transmitters are directly installed in the connecting head of the temperature sensor. The sensor signalisconvertedintoa4…20mAsignal,HARTsignalorProfibusPAsignaldirectlyonsite.Theheadtransmittersmaybefreelyprogrammedandparameterised.
Transmitter for top-hat rail assemblyIntelligentterminalsin2-wiretechnologyaresuitedtotheinstallationinsubdistributorsystemsclosetotheprocessorcontrolcabinets.Theirverysmalldimensionspermitaspace-savinginstallation.Temperaturetransmittersaredirectlyassembledinthecontrolcabinetandmainlyuse4-wiretechnology.Measuredvariablesandmeasuringrangescanbefullyprogrammedwhichfacilitatesuniveralusageandcost-savingstocks.Allofourdevicesaregalvaniclyisolated,onprinciple,andalsoavailableinEx-variants.
Asalinkbetweentheactualphysicalprocessandcontrolengineering,weprovideanextensiveprogramforsafeisolation,conversionandamplifyingofsignals,alsoforEx-zones.Safetyhasthefirst priority also at this point.
Power Supply UnitsOurpowersupplyunitsprovide2-wiretransducerswithDCpowerandtransmitthemeasuringsignal1:1 galvanicly separated to the measuring output.
Isolation amplifiersActiveisolationamplifiershavethetaskofgalvaniclyseparatinginputsignalsfromoutputsignals,amplifyingthemand/orconvertingthemtoanotherlevelortypeofsignal(currentorvoltage).DifferentEx-variantsarealsoavailable.
Passive isolatorsPassive DC signal isolators serve the galvanic isolation of a direct current signal which is transferred to a direct current or direct voltage signal depending on the device variant. They prevent the diversion ofinterferencevoltagesandinterferencecurrentsandsolveearthingproblems.
Videographic recordersThevidographicrecordersoftheLINAXA300familyarepaperlessrecordersofthelatestgeneration.Theirmodularconceptfacilitatestheflexibleadaptationtothemostvariedneeds.Dependingonthetype and design of the device users have up to 36 universal input channels at their disposal. Digital inputsandoutputs,relayoutputs,Ethernetinterface,RS485(Modbus)interfaceaswellastransducerpowersupplyareadditionalpropertiesoftheLINAXvidoegraphicrecorders.
Temperature control systemsThe goal of any control is to correct the change of the setpoint and the influence of interfering variableswithoutovershootingandswinging.However,thisisonlypossibleifthecontrollerbehavesdynamicallyandisadjustedtothetimebehaviourofthecontrollingsystem.Ourcontrollersandcontrollersystemsaretheprofessionaltoolforoptimumandhigh-qualitycontrol.A specially developed PDPI control action and optimising procedure corrects changes without overshooting and swinging. The integrated data loggers and histories register all relevant control processdatainrealtimethusfacilitatingadetailedanalysisofinterferences.User-friendlysoftwaretoolsforcommissioning(configuration,parameterising),remotediagnosisandremotemaintenancesupportandsimplifyallrelevanttasks.Ourcontrollerprogramcomprisescompactcontrollers,controlmodulesforSimaticplatforms,OEMcontrolmodules,softwarecontrollers(controlalgorithm)andmodular temperature control systems.
72
Index
Camille BauerIndex
19”assemblyrack282-wiretechnology4
AA200,A200-HH28A2000,A2000MobilSet33A210,A220,A210-HH31A230,A230s,A230-HH,A230E-HH32AnalogueinputmoduleforLON55Angular position 70APLUS34
BBT90128BusterminationforLON55
CCAM25-27
DDatacollectormoduleforLON55Datalogger25-27,30,32-35Displayunits28,30-35Displayunits,mobileuse28,31-33Display units, multifunctional 30DME421DME400(LON)24DME401/440(Modbus)23DME406(ProfibusDP)24DME424/44222
EECS46ECS-LANrouter55ECSopt63ECSwin62EDS-CAM27Electromagneticcompatibility67EMC64EMMOD201(Modbus)37EMMOD20237EMMOD203(Ethernet)38EMMOD204(Profibus)39EMMOD205(LON)39EMMOD206(M-Bus)40EMV67Energymanagement41–EnergyControlSystem(ECS)46–Softwareforenergymanagement62-65–Summators47-54Energymeters42-45Environmentalinspections69Ethernet26,32,33,35,38Extensionmodules36-40
FF534 13F535 14
GG536 15G537 16
HHarmonicsanalyses25,26,32-34
II538 5I542 5I552 6IEC61 850 26Inclination 70Isolation amplifiers– High voltage DC DC 10
LLive-zero4Load optimising 56LON24,33,39,49-55
MM-Bus40,43,52-53M561, M562, M563 20M56x 20Mavolog10S57Mavosys 10 58MeasuringunitCAM25-27Meters42-45,30Mixed current 12Mobilesystems28,31-33Modbus23,26,33,37
PP200 12P530 11P600 12Powermeters11,12,20-27Powermeters,displaying30-35Power quality 57, 58PRKAB56066Process management 71ProfibusDP24,33,39ProfibusMini-CD61Programmingcable66
QQ531 11
RRogowski27
SSamplingsystems18SMARTCONTROLECS52Software60-65–CB-Analyzer61–CB-Manager61
–Configurationsoftware60-62–ECSopt63–ECSwin62–EMC64–EncoreSeries65–MakrosforMSExcel63–METRAwin10/Mavolog57–PC.doc-Access/Mavolog57–Z302B,Z302C,Z302D62Summators46-54– Additional components 55Systemanalyses25,34,32
TTime reference 25, 33, 34, 38Transducers– Current 4 –DC-highvoltage10– Frequency 13– Frequency difference 14– Mixed current power 12– Multifunctional 18– Phase angle 15– Phase angle difference 16–PowerAC11-12,20-27– Power DC 12– Power factor 15– Unifunctional 3– Voltage 7– Voltage difference 10TV829 10
UU1281, U1289, U1381, U1387 43U1389 43U1500 56U1600 48U1600Excel-Makro63U1601 49U1602 50U1603 51U1660, U1661, U1664 55U200 53U389A,U389B45U539 8U543 8U553 9U554 9U700 10Universalmeasuringunit25-27
ZZ301A,Z301B55
Rely on us.
Camille BauerHeavy Current Engineering at a glance
Camille BauerOur Sales Partners
Only the best have always been working for
us, i.e. our customers and the market with
all of its changing and new challenges. This
implies a permanent learning aptitude which
is consistently implemented in our products
- particularly in customised solutions. And
this world-wide, always considering local
requirements, conditions and regulations.
We launch new products as announced. We
adhere strictly to confirmed delivery dates.
And: Our responsibility in relation to customers
does not end upon the conclusion of a sale.
Systematic and innovative thinking determines
our actions. The concept of all product groups is
comprehensive and integrative.
In this respect, high priority is given to the
interaction of hardware and software.
Our program may be subdivided as follows:
• Heavy current engineering
• Angular position engineering
• Process control engineering
Camille Bauer offers two options for orders:
The versatile products of Camille Bauer have
different product features. You can obtain
products via Order Code or as stock versions.
The Order Code is stated on the data sheets on
our homepage:
www.camillebauer.com.
For standard applications, use the 6-digit
Article Number stated in this catalogue. These
products are on stock and can be supplied
within 3 days.
It is a matter of course that our competent sales
partners in your country will support you in
ordering (please see the inside of the rear cover
or visit our homepage).
Our in-house area sales manager will support
you in countries which are not listed.
Rely on us:
We provide a
3-year warranty for all
Camille Bauer products.
Unifunctional transducers
Multifunctional transducers
Displaying power meters
Energy management
Software, accessories, basics
Indices
Heavy currentengineering
Angular positionengineering
Process controlengineering
Germany
GMC-I Messtechnik GmbH
Südwestpark 15
D-90449 Nürnberg
Phone +49 911 8602 - 111
Fax +49 911 8602 - 777
www.gossenmetrawatt.com
France
GMC-Instruments France SAS
3 rue René Cassin
F-91349 MASSY Cedex
Phone +33-1-6920 8949
Fax +33-1-6920 5492
www.gmc-instruments.fr
Italy
GMC-Instruments Italia S.r.l.
Via Romagna, 4
I-20046 Biassono MB
Phone +39 039 248051
Fax +39 039 2480588
www.gmc-instruments.it
Netherlands
GMC-Instruments Nederland B.V.
Postbus 323, NL-3440 AH Woerden
Daggeldersweg 18, NL-3449 JD Woerden
Phone +31 348 421155
Fax +31 348 422528
www.gmc-instruments.nl
Switzerland
GMC-Instruments Schweiz AG
Glattalstrasse 63
CH-8052 Zürich
Phone +41-44-308 80 80
Fax +41-44-308 80 88
www.gmc-instruments.ch
Spain
Electromediciones Kainos, S.A.U.
Energía 56, Nave 5
E-08940 Cornellà -Barcelona
Phone +34 934 742 333
Fax +34 934 743 447
www.kainos.com.es
Czech Republic
GMC-měřicí technika s.r.o
Fügnerova 1a
CZ-678 01 Blansko
Phone +420 516 482 611-617
Fax +420 516 410 907
www.gmc.cz
USA
Dranetz
1000 New Durham Road
Edison, New Jersey 08818-4019, USA
Phone +1 732 287 3680
Fax +1 732 248 1834
www.dranetz.com
Electrotek Concepts Inc.
9040 Executive Park Drive, Suite 222
Knoxville, TN 37923-4671, USA
Phone +1 865 470 9222
+1 865 531 9230
Fax +1 865 470 9223
+1 865 531 9231
www.electrotek.com
Daytronic Corporation
2566 Kohnle Drive
Miamisburg, Ohio 45342, USA
Phone +1 937 866 3300
Fax +1 937 866 3327
www.daytronic.com
China
GMC-Instruments (Tianjin) Co., Ltd
www.gmci-china.cn
Beijing
Rm.710, Jin Ji Ye BLD. No.2,
Sheng Gu Zhong Rd.
P.C.: 100022, Chao Yang District
Phone +86 10 84798255
Fax +86 10 84799133
Tianjin
BLD. M8-3-101, Green Industry Base,
No.6, Hai Tai Fa Zhan 6th Rd.
P.C.: 300384, Nan Kai District
Phone +86 22 83726250/51/52
Fax +86 22 83726253
Shanghai
Rm. 506 Enterprise Square BLD. No.228,
Mei Yuan Rd.
P.C.: 200070, Zha Bei District
Phone +86 21 63801098
Fax +86 21 63801098
Camille Bauer
Cam
ille
Bau
er A
G
Heavy currentengineering
Angular positionengineering
Process controlengineering
Rely on us.
Rely on us.
Camille Bauer Ltd
Aargauerstrasse 7
CH-5610 Wohlen / Switzerland
Phone: +41 56 618 21 11
Fax: +41 56 618 35 35
www.camillebauer.com
Heavy CurrentEngineering
Sub
ject
to c
hang
e w
ithou
t not
ice
SM
-10
21-
00
0-0
2-E
N-0
9.1
0