DMX-3 & 5771 Config

Embed Size (px)

Citation preview

  • 8/7/2019 DMX-3 & 5771 Config

    1/33

    11

    DMX-3 & 5771

    Aug23, 2005

  • 8/7/2019 DMX-3 & 5771 Config

    2/33

  • 8/7/2019 DMX-3 & 5771 Config

    3/33

    33

    Physical System Layout

    Broken from the wheel in, plug and play, model. Aspects of DMX 800 are incorporated. Grow the box as required. This means inter-frame cabling is required.

    Base Unit is equipment bay and at least one drive bay.

    1A2A 1B 2BSystem

  • 8/7/2019 DMX-3 & 5771 Config

    4/33

    44

    DMX-3 Front view

    Take note and remember how bays are numbered.

  • 8/7/2019 DMX-3 & 5771 Config

    5/33

    55

    System Bay (Front)

    Fans

    System Midplane

    Air Intake(8)1800W Power Supplies

    (8)SPS(only 3 shown)

    KVM

    Server

    Card Cage

  • 8/7/2019 DMX-3 & 5771 Config

    6/3366

    System Bay (Rear)

    (16) 8-Port Adapters

    (2) XCM Boards

    (8) Power Supply Cords

    (UPS) Uninterruptible Power Supply

    (2) (PDP) Power Distribution Panel

    (2) (PDU) Power Distribution Unit

    (8) (SPS) Standby Power Supplies(only 6 shown)

  • 8/7/2019 DMX-3 & 5771 Config

    7/3377

    Midplane (Front)

    Dir1

    Pos1

    SlotID0

    TypeBE

    Dir9

    Pos17

    SlotID8

    TypeFE

    Dir2

    Pos2

    SlotID1

    TypeBE

    Dir10

    Pos18

    SlotID9

    TypeFE

    Dir3

    Pos3

    SlotID2

    TypeFE

    Dir11

    Pos19

    SlotIDA

    TypeBEorFE

    Dir4

    Pos4

    SlotID3

    TypeFE

    Dir12

    Pos20

    SlotIDB

    TypeBEorFE

    Dir5

    Pos5

    SlotID4

    TypeBEor

    FE

    Dir13

    Pos21

    SlotIDC

    TypeFE

    Dir6

    Pos6

    SlotID5

    TypeBEor

    FE

    Dir7

    Pos7

    SlotID6

    TypeFE

    Dir8

    Pos8

    SlotID7

    TypeFE

    Dir16

    Pos24

    SlotIDF

    TypeBE

    M0

    Pos9

    SlotID10

    M1

    Pos10

    SlotID11

    M7

    Pos16

    SlotID17

    M6

    Pos15

    SlotID16

    M5

    Pos14

    SlotID15

    M4

    Pos13

    SlotID14

    M3

    Pos12

    SlotID13

    M2

    Pos11

    SlotID12

    Mirrored Memory Pairs

    Director Pairs

    14

    Rev 2.0 9/11/03

    15

  • 8/7/2019 DMX-3 & 5771 Config

    8/3388

    Card Cage Front

    Each Director has 4 slices

    Each Slice has 2 ports

    DAs come in pairs

    Each DA pair drives 8 DAEs (Primary)

    Dirs 5,6,11,12 could be HAs

    Memory comes in pairs (Mirrored)

    Both cards must be the same size

    Available memory sizes are:8GB, 16GB, 32GB, 64GB

  • 8/7/2019 DMX-3 & 5771 Config

    9/3399

    Universal Director

    Jtag RS232 Ethernet

    DisableInterface

    Switch

    Boot UpMode

    Selection

    StatusDisplay ProcessorSelectedDisplay

    CPU SelectionSwitch for FBUart, Attn. and

    Status Display

    A,B,C,DMachineOk LED

    MachineCheckError on

    A,B,C,D

    Attn.Switch

    PICFault

    LED

    FRUBlue

    LED

  • 8/7/2019 DMX-3 & 5771 Config

    10/331010

    Cache Configuration Rules: Sym7 vs Sym6

    Restrictions 1 and 3 exist on Sym6 to avoid I/O contention

    Restrictions 4-5 are new to Sym7 due to mirroring method

    Cache Boards are available in 8GB,16Gb, 32GB, 64GB capacities.

    Rule Sym 6 Sym 7

    1 2 board configs must use same size board 2 board configs must use same size board

    2 Largest board no more than twice size of smallest board No restriction on largest vs smallest board

    3 Cannot have fewer of the larger board than the smaller board Cannot have fewer of the larger board than the smaller board

    Example: (2 x 8GB + 6 x 16GB) OK Example: (2 x 8GB + 6 x 16GB) OK

    Example: (4 x 8GB + 4 x 16GB) OK Example: (4 x 8GB + 4 x 16GB) OK

    Example: (6 x 8GB + 2 x 16GB) not allowed Example: (6 x 8GB + 2 x 16GB) not allowed

    4 Odd no. of total boards allowed Odd no. of total boards not allowed

    Example: 3 x 16GB OK Example: 3 x 16GB not allowed

    5 Odd no. of individual boards allowed Odd no. of individual boards not allowed

    Example: (3 x 16GB + 3 x 8GB) OK Example: (3 x 16GB + 3 x 8GB) not allowed

  • 8/7/2019 DMX-3 & 5771 Config

    11/331111

    Card Cage Rear

    B0B1

    A0A1

    D0D1C0C1

    XCM Card

    Combination of the

    Communications Control Module(CCM) card and EnvironmentalControl Module (ECM) card

    Handles communication

    switching and card cageenvironmental monitoring

    Directors responsible for localenvironmental monitoring

  • 8/7/2019 DMX-3 & 5771 Config

    12/331212

    Drive Bay

    1 Pod has 4 X DAEs

    1 X DA pair drives 8 DAEsMinimum upgrade granularity @ GA

    Drives count 0-E

    E

    0

    Drive 2A 05 A

    Drive slots 0, 1, 4, 5, 8, 9, C, D are one power branch.Drive slots 2, 3, 6, 7, A, B, E are the other branch.

    Bay DAE Drive

  • 8/7/2019 DMX-3 & 5771 Config

    13/331313

    DAEs Rear View

  • 8/7/2019 DMX-3 & 5771 Config

    14/331414

    Connecting the Daes to Das

    16 A0

    16 B001 B0

    01 A0

    16 D0

    16 C0

    01 D0

    01 C0

    16 D116 C1

    01 D1

    01 C1

    16 A1

    16 B101 B1

    01 A1

  • 8/7/2019 DMX-3 & 5771 Config

    15/33

    1515

    Note: At GA max of 4 Storage Bays, 8 Storage Bays post-GAMinimum GA Configuration will have 3 DA pairs

    Yellow = Dir 1 & 16

    Green = Dir 2 & 15

    Orange = Dir 5 & 12

    Blue = Dir 6 & 11

    Connecting Up

    FID 94; Symm7 only

  • 8/7/2019 DMX-3 & 5771 Config

    16/33

    1616

    PowerVault

    Redesign of the power-down process to dump pertinent GlobalMemory information to specified Power Vault drives.

    Need a predictable, fast and consistent solution to deal with Cache current method of de-staging Global memory is not scaleable.

    Not predictable due to what's happening at the time. Increase in Global Memory sizes (512GB raw) along with stagnant battery

    technology meant we could potentially run out of battery time before we hadcompletely de-staged memory.

    Symmwin will automatically configure Vault devices. Do not block move or fiddle with Vault devices. Power Vault requirement is 4 unprotected volumes per DA slice.

    Must be on primary DAEs which cannot be configured with less than 4 drives. Current Size is 5gb but appear as 0 cyls in bin file.

    Power Vault devices are formatted as raw FBA drives and cannot be read using D0commands using Cyl and HD because of this.

    Vault Devices are assigned to be the first logical position on a physical drive.

    This is the fastest part of the physical drive (Outer Diameter) Insures the highest possible throughput

    FID 94; Symm7 only

  • 8/7/2019 DMX-3 & 5771 Config

    17/33

    1717

    DAE

    LCC

    LCC

    SPS

    DAF1

    DAF16

    o 4 Vault Drives per DA slice

    o 5 GB per Vault drive

    To Daisy Chain DAE

    PowerVault

  • 8/7/2019 DMX-3 & 5771 Config

    18/33

    1818

    Vault Save AllocationExample

    PV

    DEV

    B

    Dir

    1B

    PV

    DEV

    D

    Dir16A

    PV

    DEV

    A

    Dir

    1A

    PV

    DEV

    D

    Dir

    1D

    PV

    DEV

    A

    Dir

    16D

    PV

    DEV

    B

    Dir16C

    PV

    DEV

    C

    Dir16B

    Region 0

    Dir 1D

    Region ABC

    Region DEF

    PV

    DEV

    C

    Dir

    1C

    Dir 1C

    Dir 1B

    Dir 1ADir 16A

    Dir 16B

    Dir 16C

    Dir 16D

    Region

    Region UVW

    .

    .

    Each region issaved twice.

    This is forredundancy.

    You do NOT get acopy of each mirrorimage of memory

  • 8/7/2019 DMX-3 & 5771 Config

    19/33

    1919

    Changes to IML

    Restore Global Memory from previously successful Vault Save image. This is done in step 14 of the IML

    Step 14 also incorporates an extensive Sanity Check of global memory

    Error codes that may be seen will reported as ECxx errors

    Drive availability Sanity Check Check that all Drives previously in the System are in the same place by comparing

    the S/N of the drives since the last successful restore.

    Error DD10.01 will be issued if we find the drives in a different slot than before.

    At the end of the Restore check that both images of GM match bycalculating the CRCs for the 2 matching Vault regions of memory

    Error 3310.00

  • 8/7/2019 DMX-3 & 5771 Config

    20/33

    2020

    Vault Implications

    System VTOC: the Vault drives will be formatted and a Vault Saveoperation will take place at the end of a successful VTOC.

    When a System is taken Offline (DAs) a Vault Save operation will takeplace.

    The Front End and RDF can be taken offline and back online without a Vault.

    Can not take one DA offline, all or none.

    Environmental triggers loss of a sufficient number of Fans

    loss of a sufficient number of Vault drives

    loss of Battery hold up time meaning we would not be able to Vault if AC Power waslost.

    If the system determines theres not enough power to vault it wont come up.

    A lack of SPS Battery hold up time will prevent the box from coming online

    The box will still complete IML.

    The state would remain in Post Restore IML.

  • 8/7/2019 DMX-3 & 5771 Config

    21/33

    2121

    Init Screen

    Model name DMX3-24 or DMX3-6

    Power vault wait time

    Raid-S no longer supported

  • 8/7/2019 DMX-3 & 5771 Config

    22/33

    2222

    Dir Map tab Changes

  • 8/7/2019 DMX-3 & 5771 Config

    23/33

    2323

    DAE

    Much like adding disks use the

    wizard or type in the letter

  • 8/7/2019 DMX-3 & 5771 Config

    24/33

    2424

    Split Screen

    Unlike the Hosts tab this one is compulsory

    Helps to maintain addressing rules.

  • 8/7/2019 DMX-3 & 5771 Config

    25/33

    2525

    Addressing CKD devices

    Gives the capability toaddress multiple CU imagesat the same time.

  • 8/7/2019 DMX-3 & 5771 Config

    26/33

    2626

    Disks

    Add new option as to where you wantto place disks.

    Note as you change DAE the colourschange.

    Physical view functionality added.

  • 8/7/2019 DMX-3 & 5771 Config

    27/33

    2727

    Physical view from Vols Map

  • 8/7/2019 DMX-3 & 5771 Config

    28/33

    2828

    Vols Request

    128 Vault devices. 16 per DA director. 4 per DA slice.

    VCM data base now lives on SFS volumes so the device is samesize as a gatekeeper.

    New protection type CDEV (cache only device)VDEV lives in Cache, no longer takes up Physical disk space.

    Raid-S no longer supported.

    Be Careful traditionally this would be a 9Gb drive Now its double that, remember this when playing with SRDF.

    FBA track size Doubled to 64KB

    Fewer tracks or slots per GB of user data

    Both FBA and CKD will use a 64KB track, so any systemcan mix FBA and CKD devices

    FIDs 420,662,663,664; Symm6 & Symm7

  • 8/7/2019 DMX-3 & 5771 Config

    29/33

    2929

    SRDF Inter-platform Support

    Platform RDF Configuration Level of Support

    Symm 4 5267 to 5x71 Migration only

    Symm 5 5567 to 5x71 Migration only

    5568 to 5671 Full support

    5568 to 5771 Full support

    Symm 6 5669 to 5x71 none

    5670 to 5671 Full support

    5670 to 5771 None

    5671 to 5x71 Full support

    Symm 7 5771 to 5771 Full support

    Includes all link types: ESCON, FC, GigE

  • 8/7/2019 DMX-3 & 5771 Config

    30/33

    3030

    Numbers

    5670 5671 5771

    Volumes Supported 8,000 16,000 64,000*

    CUs in a box 64 64 250

    MF LPARs per slice 64 64 128MF ESCON concurrent I/O 4 8 8

    MF Aliases 7 15 255

    iSCSI Initiators per Slice 128 128 512

    * 32,000 if everything is Raid 7+1

  • 8/7/2019 DMX-3 & 5771 Config

    31/33

    3131

    New and Noteworthy

    Cable diagnostics Runs automatically during configure and install Symmetrix

    Checks out basic cabling connectivity & functionality

    Steps CE through a sequence where the DAEs are lit up First vertically thenhorizontally 1 frame at a time.

    Provides opportunity to correct any problems before moving on.

    Can also be run anytime from menu.

    Drive replacement script Drive replacement script has been improved to run mostly unattended.

    After testing basic drive functionality CE is released.

    Script monitors and will dial home if problems occur.

    SCSI code load Planning script and a load script.

    Gives CE options on how when and where to load.

    Can run in flavors ranging from Big Bang Mode to unattended Super safe mode.

  • 8/7/2019 DMX-3 & 5771 Config

    32/33

    3232

    5771 Procedure Wizard changes

    Symm 7specificoptions

    Starts vaultingprocess prior topower down.New cableoptions

    Global sparing notyet available

    No offlinechanges

  • 8/7/2019 DMX-3 & 5771 Config

    33/33

    3333