litersin3
mmin
mmin
kglbkglb
rpm 1200 1500 1800 1900kW 273 315 315 315hp 372 428 428 428
with fan kW 265 303 295 291890 mm hp 361 412 401 396
Nm 2175 2005 1671 1583lbf ft 1604 1479 1232 1168Nmlbf ft%
m/s 6,3 7,9 9,5 10,0ft/sec 20,7 25,9 31,1 32,8MPa 2,14 1,97 1,64 1,56psi 310 286 238 226
MPa 15,4 15,6 14,6 14,3psi 2233 2262 2117 2074
kgm²(not including flywheel) lbft²
kW 21 31 45 51hp 29 42 61 69
Document No Issue IndexTAD1372VE 22323790 04
Bore 1315,16
Stroke 1586,22
This Technical Data Sheet and the corresponding Installation Instructions provide important information to ensure the installed engine will operate according to the design specification in the Volvo Penta application for certification.
Requirements marked with are considered as critical for exhaust emissions compliance according to the design specification in the Volvo Penta application for certification.
Failing to follow and meet these instructions and requirements when installing a certified engine in a piece of nonroad equipment for use in the United States violates U.S. federal law (40 CFR 1068.105(b)), subject to fines or other penalities as described in the Clean Air Act.
In-line four stroke diesel engine with direct injection. Rotation direction, counterclockwise viewed towards flywheel
Number of cylinders 6Displacement, total 12,78
Compression ratio 17,8:1Wet weight Engine only (Estimated)
(excl after treatment comp.)13252921
Power pac 1790
780Firing order 1-5-3-6-2-4
3946
PerformanceIFN Power 315 kW without fan
21751604
Torque at: IFN Power
Max torque at engine speed
rpm 1200 rpm
Max combustion pressure at: IFN Power
Total mass moment of inertia, J (mR2) 1,14327,1
Power tolerance ±2Mean piston speed
Effective mean pressure at: IFN Power
Friction Power
Derating see Technical Diagrams
1/19
Document No Issue IndexTAD1372VE 22323790 04
rpm 1200 1500 1900 2200kW 70 128 240 283hp 95 174 326 385Nm 557 815 1206 1228lbf ft 411 601 890 906rpmrpm°C
°C°F°C°F°C°F
Vol%
literUS gal
Max literUS gal
Min literUS gal
hh°°°
kPapsi
max °C°F
99% µ50% µ
Engine speed range for VCB activation: 1000-2200Min engine speed with VCB still active: 900Min oil temperature for VCB activation: 55
Engine brake performance (only engines with VCB)Brake power: without fan
Brake torque: without fan
-13with manifold heater 3 kW and block heater
-30-22
*Specify oil and fuel quality T>-15°C Oil VDS3 or VDS4 15W/40 T<-15°C Oil VDS3 or VDS4 5W/40
Cold start performance*Cold start limit temperature without starting aid -15
5with manifold heater 3 kW -25
Heater type Make Power kW Engaged hours(-30°C)
Cooling water temp engine block
Self circulating Volvo 21578298 2 12 -1°C30°F
* See also general section in the sales guide
Lubrication system0,02Lubricating oil consumption (average)
Oil change intervals/specifications VDS3 1000VDS4 1000
Oil system capacity including filters 369,51
Oil pan capacity:(both variants)
307,9319
5,02
Oil pressure at rated speed 300 - 65044 - 94
Engine angularity limits: front up 11front down 11side tilt 11
Lubrication systemLubrication oil temperature in sump: 130
266Oil filter filtration efficiency(in accordance with ISO 4548-12)
3814
2/19
Document No Issue IndexTAD1372VE 22323790 04
liter/hUS gal/h
kPapsikPa
(meassured at fuel inlet connection) psikPa
(meassured at fuel inlet connection) psiliter/h
US gal/hkPapsi°C°Fµ
96% µ75% µ
Vol%
rpm 1200 1500 1800 1900m³/min 19,0 25,0 26 27
cfm 671 883 918 954
kPapsikW 187 233 252 253
BTU/min 10635 13250 14331 14388°C 438 418 439 444°F 820 784 822 831
kPa 12 16 18 18125 mm psi 1,7 2,3 2,6 2,6
Δ°C 10 10 10 10Δ°F 18 18 18 18kPa 8 9 10 10
(at exhaust gas flow and exhaust temp given) psi 1,2 1,3 1,5 1,5
m³/min 44,0 54,0 57 58cfm 1554 1907 2013 2048
System supply flow at max. Speed 13034,3
Fuel supply line max. restriction (measured at fuel inlet connection)
304,4
Specific UREA consumption in Nonroad Transient Cycle (NRTC) 4,7
Fuel system
Fuel supply line max. pressure, during engine stand still 16523,9
System return flow at max. Speed 30,07,9
Fuel supply line min. pressure, during engine stand still -125-18,1
Fuel filter filtration efficiency
Charge air consumption at:(+25°C and 100kPa)
IFN Power
Fuel return line max. restriction(measured at fuel return connection)
202,9
Max. allowable inlet fuel temp(Measured at fuel inlet connection)
60140
Fuel to conform to Fuel equal to or better than EN590:2009 or ASTM D975-09 and Max sulphur 15ppm
Intake and exhaust system
64
Governor type/make, standard Volvo/EMS2.3
Prefilter / Water separator micron size 10
Exhaust gas temperature after turbine at: IFN Power
See front page for important information
Max allowable back pressure in exhaust line (after turbine)
60,9
Heat rejection to exhaust at: IFN Power
See front page for important information
Max allowable air intake restriction including piping
Pipe dimension Ø:
See front page for important information
Max allowable temperature drop between turbine and SCR muffler inlet.SCR muffler pressure drop
Exhaust gas flow at:(temp and pressure after turbine at the corresponding power setting) IFN Power
3/19
Document No Issue IndexTAD1372VE 22323790 04
rpm 1200 1500 1800 1900kW 7,1 7,2 7,4 7,4
BTU/min 404 409 421 421kW 113 135 144 153
BTU/min 6426 7677 8189 8701
m²foot²mmin
kW 4,0 6,0 10,0 12,0hp 5 8 14 16
literUS gal
literUS gal
Coolant pump drive/ratiol/s 3,7 4,7 5,7 6
US gal/s 1,0 1,2 1,5 1,6l/s 3,2 4,2 5,5 5,5
US gal/s 0,8 1,1 1,5 1,5kPapsi°C°F°C°F
kPapsikPapsikPapsi°C°F
literUS gal
Coolant Yellow Volvo Coolant Solution (VCS)Radiator cooling system type Closed circuit
Cooling systemHeat rejection radiation from engine at: IFN Power
Heat rejection to coolant at: IFN Power
Fan diameter 890 mm 89035,04
Standard radiator core area 0,88,61
Fan drive ratio fan Ø890 0,84:1 ccw
Fan power consumption 890 mm
6,3belt/1,41:1 cw
Coolant flow with standard system
Coolant capacity: engine 205,3
std. 0,8m² radiator with hoses 24
180fully open 92
198Maximum static pressure head(expansion tank height + pressure cap setting)
10014,5
Minimum coolant flow
Maximum outer circuit restriction incl. piping 65,09,4
Thermostat: start to open 82
Maximum top tank temperature 107225
Recommended Draw down capacity. The difference between min coolant level in the expansion tank and the lowest level where the engine's coolant system still are functioning
20,5
Minimum static pressure head(expansion tank height + pressure cap setting)
7010,2
Standard pressure cap setting 7510,9
4/19
Document No Issue IndexTAD1372VE 22323790 04
rpm 1200 1500 1800 1900kW 47 63 62 60
BTU/min 2673 3583 3526 3412kg/s 0,38 0,5 0,52 0,52°C 163 175 170 164°F 325 347 338 327
°C 42 50 50 50°F 108 122 122 122
kPapsikPa 191 205 175 163psi 27,70 29,73 25,38 23,64m²
foot²
0,8 Pull 890 fan
rpmkWhp °C °F m3/s ft3/s Pa psi
1900 315 62 144 6,2 219,0 310 0,0450,84 428 64 147 6,7 236,6 175 0,025
66 151 7,3 257,8 0
0,8 Push 890 fan
rpmkWhp °C °F m3/s ft3/s Pa psi
1900 315 63 145 6,3 222,5 270 0,0390,84 428 64 147 6,6 233,1 185 0,027
66 151 7,2 254,3 0
Charge air mass flow IFN PowerCharge air inlet temp.(Charge air temp after turbo compressor)
IFN Power
Charge air cooler systemHeat rejection to charge air cooler IFN Power
See front page for important informationMaximum pressure drop over charge air cooler incl. piping 12
1,74Charge air pressure(After charge air cooler)
See front page for important informationMax allowable Charge air outlet temp.(Charge air temp after charge air cooler)
Engine speed Engine power Air on temp Air flow External restriction
Standard charge air cooler core area 0,88,61
Cooling performance: m² radiator andCooling air flow and maximum additional external restriction at different radiator air temperatures based on 107°C TTT and 40% coolant. Valid at 1 atm.
Cooling performance: m² radiator andCooling air flow and maximum additional external restriction at different radiator air temperatures based on 107°C TTT and 40% coolant. Valid at 1 atm.
Engine speed Engine power Air on temp Air flow External restriction
5/19
Document No Issue IndexTAD1372VE 22323790 04
Isochronous
0Adjustable PI-constants
600-900Energized to run/Stop
On/OffOn/Off
°C 125Oil pressure kPa 25,0
kPa 275
°C 105On
kPa5
°C 120
kPa
Warning map value
+20kPa
* Off means no shut down, alarm only
Warning Alarm
Derated 0% to engine protection map
Derated 100% to engine protection map
105°C 107°C 107°C 108°C125°C 127°C 127°C 130°C
Warning map value
Alarm map value
N/A N/A
120°C 125°C 125°C 126°CWarning
map value
Alarm map value
Alarm map value
Alarm map value
Governor droopGovernor response 1Idle speed 700
Engine management systemFunctionality Alternatives Default settingGovernor mode
Engine sensors and switch settings Alarm level Engine protection
Stop functionPreheating functionLamp test
Rated speed 300 Shut down, ON/OFF*Oil level
Oil temp Setting +5 Shut down, ON/OFF*Low idle 50 Shut down, ON/OFF*
Parameter Unit Setting range Default setting Level Action.
Default/Alternative
Coolant temp 107 Shut down, ON/OFF*Coolant level See cooling system
Piston cooling pressure>1000 rpm
kPa
Water in fuel Alarm When ClosedCrank case pressure Rapid Pres inc Shut down,
Fuel feed pressure
1200rpm kPa 100
Shut down, ON/OFF*
Air filter pressure dropAltitude, above sea m Automatic derating,
see section derating
Coolant temp N/A N/AOil temp
Engine speed rpm x % of rated speed 125% of rated speed
Alarm level Shut down, ON/OFF*
Parameter Forced idle after sec
Forced shut down after 2 sec
Charge air temp 125 Shut down, ON/OFF*
Charge air pressureAlarm map value
+30kPa
High charge air temp N/A N/AHigh charge air pressure N/A N/A
N/A N/ALow oil pressure N/A Alarm map value
6/19
Document No Issue IndexTAD1372VE 22323790 04
AHz/alternator rev.
typekWhp
flywheelstarter motor
kWA
Temperature °C 25 0 -15Battery Ah / CCA 235 / 1300 145 / 1050 145 / 1050
rpm 171 118 98A 290 400 480
kW 6,2 7,5 7,7kW 6,5 8,1 8,5
Ah / CCA
rpm 1200 1500 1800 1900Nm 2210 2030 1680 1580
(with a total added mass moment of inertia, J (mR2)≤0,05 kgm²) lbf ft 1630 1497 1239 1165max left kW 42 53 62 68
hp 57 72 84 92max down kW 36 44 52 60
hp 49 60 71 82max right kW 42 53 62 68
hp 57 72 84 92Nmlbf ft
Nmlbf ft
Nmlbf ft
Nmlbf ft
Nlbf
Starter input power during crankBattery power during crank
Power take offFront end in line with crank shaft max:*
Conditions:(4 mΩ main circuit resistance@
Min battery @ 0°C 140/800
1
Max. rear main bearing load 4000899,2
443Speed ratio direction of rotation viewed from flywheel side 1,31:1/ccwMax allowed bending moment in flywheel housing 15000
11063
Maximum torque on timing gear at rear PTO : * 1000738
Speed ratio direction of rotation viewed from flywheel side 1,31:1/ccwTiming gear at compressor PTO max:* 600
Front end belt pulley load. Direction of load viewed from flywheel side:
Timing gear at servo pump PTO max:* 10074
Speed ratio direction of rotation viewed from flywheel side 1,58:1/ccw
* Maximum allowed torque at individual PTO´s.If more then one PTO output is used simultaniusly, calculations needs to be performed to determine available maximum. Available torque depends on application inertia.
tacho output 6drive ratio 5,25
105P70 / (105P70 ISS för start/stop)
Electrical systemVoltage and type 24VAlternator: output
Starter motor:
110/150
output
Number of teeth on:
Crank speedCrank current
79,515312
Inlet manifold heater (at 20 V) 3Power relay for the manifold heater
7/19
Performance Power (kW) RpmIFN Power 315 1900
Signal Range Derating level
0,5-4,5 V 50 - 400 kPa map50-0 kΩ -40° - 130 °C 125°CDigital50-0 kΩ -40° - 140 °C 107°C0,5-4,5 V 0 -15 kPa Rapid pres
incFrequencyFrequency
575N/A
50-0 kW -40° - 140 °C 127°C
Signal Range0,5-4,5 V 50 - 400 kPa 600 1000 1200 1500 1900
363 363 363 335 290373 373 373 345 300
0,5-4,5 V 0-700 kPa 0 500 1000 1500 19001 50 200 300 3001 25 175 275 275
0,5-4,5 V 0-700 kPa 600 1000 1200 1800 1900100 100 100 300 300N/A N/A N/A N/A N/A
22323790 04
Derating
Boost pressure N/A map value+30 kPa
Sensors Alarm Alarm switch Alarm Level Condition/Delay
Soft derate VE/ Coolant level switch Alarm when closed Low
Soft derate VE/Crankcase pressure N/A Rapid pres inc ShutdownCoolant temperature
Document No Issue Index
Boost temperaure N/A 120°CSoft derate VE/
N/A 105°C
N/AEngine Speed Crank N/A Lost sign N/AEngine Speed Cam N/A Lost sign
Soft derate VE/ Oil level sensor Alarm when low level N/A N/A
Exhaust gas temp N/A 550
Soft derate VE/Oil temperature N/A 125°C
Charge Air pressureSensors Alarm rpm Map Condition Derating
Alarm Level Soft derate VE/
Shut downFuel pressure
Oil pressureWarning Level
TAD1372VE
Warning Level
Alarm Level
Alarm Level
Warning Level
8/19
22323790 04Document No Issue Index
TAD1372VE
1) Soft derate Coolant temp Speed / °C 105°C 107C 108°C Derate map R2
Remaining torque in % 600 100% 100% 85% °C 105 107 1081200 100% 100% 40% % 0 0 1001500 100% 100% 0%
2) Soft derate Oil temp Speed / °C 125°C 127°C 130°C Derate map R2
Remaining torque in % 600 100% 100% 85% °C 125 127 1301200 100% 100% 40% % 0 0 1001500 100% 100% 0%
3)Soft derate Boost Temp Speed / °C 120°C 125°C 126°C Derate map R2
Remaining torque in % 600 100% 100% 85% °C 120 125 1261200 100% 100% 40% % 0 0 1001500 100% 100% 0%
4)Soft derate Exhaust temp Speed / °C 550°C 560°C 575°C 580°C Derate map R2
Remaining torque in % 600 100% 100% 100% 85% °C 550 560 575 5801200 100% 100% 100% 40% % 0 0 0 1001500 100% 100% 100% 0%
Max Torque High Map R2 400 600 700 800 900 1000 1050 1100 1200 1250 13001200 1050 1225 1400 1650 2130 2130 2130 2175 2153 21301400 1450 1500 1600 1700 1800 1900 1910 20052130 2075 2005 1879 1769 1670 1583 1550 500
400 600 700 900 1050 1200 1300 1400 1450 1500 1800900 900 900 900 900 900 900 500 250 0 0
Max Torque Engine Protection Map R2
9/19
Issue Index
04Document No
TAD1372VE 22323790
0
50
100
150
200
250
300
350
0 500 1000 1500 2000 2500
kW
rpm
Power
IFN Power 315 kW
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
Nm
rpm
Torque
IFN Power 315 kW
10/19
Issue Index
04Document No
TAD1372VE 22323790
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
Nm
rpm
0m 1000m 1700m 2500m 3500m
Altitude derated Torque IFN Power 315
11/19
Issue Index
04Document No
TAD1372VE 22323790
0
100
200
300
400
500
600
700
800
900
1000
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Nm
rpm
Max Torque Engine Protection Map R2
Engine protection map
12/19
Issue IndexDocument No
22323790 04TAD1372VE
190
195
200
205
210
215
600 800 1000 1200 1400 1600 1800 2000 2200
g/kWh
rpm
Fuel Consumption
IFN Power 315 kW
0
0,05
0,1
0,15
0,2
0,25
0,3
0,35
0,4
0,45
0,5
600 800 1000 1200 1400 1600 1800 2000 2200
g/kWh
rpm
Smoke emission
IFN Power 315 kW
13/19
Issue IndexDocument No
22323790 04TAD1372VE
75
125
175
225
275
325
500 700 900 1100 1300 1500 1700 1900 2100
Fuel P (kPa)
rpm
Fuel Pressure Limits
Warning Level
250
270
290
310
330
350
370
390
500 700 900 1100 1300 1500 1700 1900 2100
CAC P abs (kPa)
rpm
Charge Air Pressure Limits
Warning Level Alarm Level
14/19
Issue IndexDocument No
22323790 04TAD1372VE
0
50
100
150
200
250
300
350
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Oil P abs (kPa)
rpm
Oil Pressure Limits
Warning Level Alarm Level
15/19
Issue IndexDocument No
22323790 04TAD1372VE
40
50
60
70
80
90
100
110
120
20 31,5 50 80 125 200 315 500 800 1,25 2k 3,15 5k 8 12,5 20k
dB (A)
Frequency Hz
Sound power level engine body 1/3 octave band analysis
IFN Power 315 kW
9698
100102104106108110112114116118120
0 500 1000 1500 2000 2500
dB(A)
rpm
Sound power level Total sound level at full load
IFN Power 315 kW
16/19
Issue IndexDocument No
22323790 04TAD1372VE
020406080
100120140160180200
0 1 2 3 4 5 6 7 8 9 10
Outer circuit restriction kPa
Outer circuit flow liter/s
Outer circuit restriction versus coolant flow
Max outer circuit restriction Std. Cooling system restriction
1200 rpm Eng. speed 1500 rpm Eng. speed
1800 rpm Eng. speed 2200 rpm Eng. speed
2400 rpm Eng. speed 2600 rpm Eng. speed
10,0
15,0
20,0
25,0
30,0
35,0
40,0
45,0
50,0
31,5 63 125 250 500 1000
dB (A)
Frequency Hz
SCR Muffler transmission loss
17/19
Issue IndexDocument No
TAD1372VE 22323790 04
0
2
4
6
8
10
12
14
16
18
20
0 2 4 6 8 10 12
kW
m³/s
Standard fan Ø
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
0 2 4 6 8 10 12
Static pressure kPa
m³/s
Standard fan Ø
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
2
4
6
8
10
12
14
16
18
20
0 2 4 6 8 10 12
kW
m³/s
Standard fan Ø 890mm Pull 0,84:1
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
0 2 4 6 8 10 12
Static pressure kPa
m³/s
Standard fan Ø 890mm Pull 0,84:1
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
2
4
6
8
10
12
14
16
18
20
0 2 4 6 8 10 12
kW
m³/s
Standard fan Ø
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
0 2 4 6 8 10 12
Static pressure kPa
m³/s
Standard fan Ø
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
2
4
6
8
10
12
14
16
18
20
0 2 4 6 8 10 12
kW
m³/s
Standard fan Ø 890mm Pull/Push 0,84:1
1008 rpm 1260 rpm 1512 rpm 1596 rpm
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
0 2 4 6 8 10 12
Static pressure kPa
m³/s
Standard fan Ø 890mm Pull/Push 0,84:1
1008 rpm 1260 rpm 1512 rpm 1596 rpm
18/19
Issue Index
BSFC [g/kWh]
Fuel consumption [l/h]
04Document No
TAD1372VE 22323790